cut through the complexity of machinery analysis with … · machinery analysis with high frequency...
TRANSCRIPT
![Page 1: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/1.jpg)
Emerson Confidential
Cut Through the Complexity of Machinery Analysis with High Frequency Vibration Analysis
Dieter Charle
Business Development Manager - Europe
![Page 2: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/2.jpg)
Emerson Confidential 2
Centrifugal pump
Funny Noise
– Belt driven
– 869 RPM
– Variable speed
![Page 3: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/3.jpg)
Standard vibration data
• Relative low impacting in waveform ~4Gs
• No clear defect frequencies in the FFT spectrum
![Page 4: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/4.jpg)
Time waveform & PeakVue Spectrum
![Page 5: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/5.jpg)
PeakVue time waveform after & before
![Page 6: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/6.jpg)
Visible damage
![Page 7: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/7.jpg)
What is PeakVue?
PeakVue is a method that detect high frequency vibrations in an early stage that often originates from impacting (metal to metal contact)
Common machine faults that generate stress waves are:
– Bearing faults
– Gear mesh in gear boxes
– Looseness
– Lubrication faults
– Cavitation
![Page 8: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/8.jpg)
Emerson Confidential 8
How creating a Vibration Spectrum
Am
pli
tud
e
Time
Am
plitu
de
Am
pli
tud
e
![Page 9: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/9.jpg)
Emerson Confidential 9
Demodulation
Enveloping registers (Demodulation)
Raw measurement data - Waveform
Signal after rectifying
Signal after band pass filter
Am
plit
ud
e
Frequency
BPFOFFT
![Page 10: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/10.jpg)
Emerson Confidential 10
Am
plit
ud
e
Frequency
PeakVue
Peak Impact Detection registers
- Keep High Frequency Sample
- No Low Pass Filter
Raw measurement data - Waveform
Signal after rectifying
Signal after band pass filter
FFT
![Page 11: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/11.jpg)
How does it work?
The diagram below shows sampling of data using normal data collection
Stress wave - this is missed
under normal conditions
Instantaneous Samples
![Page 12: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/12.jpg)
How does it work?
The diagram below shows sampling of data using PeakVue data collection.
PeakVue samples
Stress wave - this is now
captured with PeakVue sampling
![Page 13: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/13.jpg)
How Does it work?
PeakVue uses Peak Hold-function to transform high frequency vibrations down to fundamental frequencies,
allowing analysis of data to be done more quickly and easily
– For normal vibration measurements the Fmax setting in the analyzer determines the sampling frequency for the collected time waveform(e.g. 1000 samples/second)
– PeakVue always sample with over 100 000 samples/second
– After collecting all the samples PeakVue discard samples so there remain only as many samples per second as the regular data collection would use for a certain Fmax
![Page 14: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/14.jpg)
How Does it work?
PeakVue samples
Sampling time
PeakVue time
waveform
Standard time
waveform
Fmax = 2 kHzZoom!
![Page 15: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/15.jpg)
Emerson Confidential 15
When using PeakVue, keep in mind:
• Sensor Mounting effects frequency range
– More rigid mounting = Higher frequency range
– Mount the sensor on a paint free clean surface if possible
– 100 mV/g accelerometer is typically used
• Mounting location of the sensor is important
– The accelerometer is mounted near the origin of the stress wave
– The accelerometer is mounted in the load zone if possible
![Page 16: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/16.jpg)
Emerson Confidential 16
Earlier detection of integrity degradation
PeakVue differentiator area’s:
- At assets with rolling element bearings & gearboxes
- Detection of metal to metal contact due lubrication issues
- Very heavy and / or slow rotating equipment
![Page 17: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/17.jpg)
Emerson Confidential
Any Questions?
Slide 17
Dieter CharleBDM Portable Reliability [email protected]+32 493 229 991
![Page 18: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/18.jpg)
Case Study: Standard vibration dataG
1
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
M1
M2
The standard spectrum was taken
Is there a problem?
![Page 19: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/19.jpg)
Case Study: PeakVue data
• PeakVue spectrum:
– Distinct peaks at 6,91 Hz and harmonics
– Corresponds to the running speed of the third shaft
• PeakVue time waveform:
– One big impact per revolution at G5
– Amplitude level of approximately 13 g Peak-to-Peak
G1
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
M1
M2
![Page 20: Cut Through the Complexity of Machinery Analysis with … · Machinery Analysis with High Frequency Vibration Analysis ... Earlier detection of integrity degradation ... Case Study:](https://reader031.vdocuments.us/reader031/viewer/2022022602/5b51702c7f8b9a56588c12a9/html5/thumbnails/20.jpg)
Case Study: The fault
Examination suspected a gear fault at G5
caused by damaged tooth
G1
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
M1
M2