POWER LEGEND SINGLE RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE, HALF SWITCHED DUPLEX RECEPTACLE, CEILING MOUNTED DUPLEX RECEPTACLE, FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE, FLOOR MOUNTED SPECIAL RECEPTACLE SPECIAL RECEPTACLE, FLOOR MOUNTED JUNCTION BOX, WALL OR CEILING MOUNTED DISCONNECT SWTICH (NON-FUSED) DISCONNECT SWITCH (FUSED) COMBINATION STARTER/DISCONNET ELECTRICAL PANELBOARD OR OTHER CABINET AS NOTED PLUG MOLD (MULTI-OUTLET ASSEMBLY) CONNECTION TO EQUIPMENT CONDUIT EXPOSED CONDUIT TURNING DOWN CONDUIT TURNING UP CONDUIT CAPPED MAIN SWITCHBOARD/DISTRIBUTION CENTER CURRENT TRANSFORMER GENERATOR ANNUNCIATOR PANEL DESCRIPTION SYMBOL DESCRIPTION SYMBOL CLG J M WM T CT GANN MOTOR CONDUIT CONCEALED GROUND BAR TRANSFORMER THERMOSTAT LIGHTING LEGEND RECESSED FLUORESCENT LUMINAIRE, LAY-IN GRID CEILING, LOWERCASE SCRIPT INDICATES SWITCHING; UPPERCASE INDICATES LUMINAIRE TYPE. RECESSED FLUORESCENT LUMINAIRE, FLANGED SURFACE MOUNTED LUMINAIRE SURFACE OR PENDANT MOUNTED STRIP SURFACE MOUNTED WALL LUMINAIRE PENDANT MOUNTED LINEAR LUMINAIRE RECESSED DIRECT/INDIRECT LUMINAIRE SURFACE MOUNTED CEILING LUMINAIRE SURFACE MOUNTED WALL LUMINAIRE RECESS MOUNTED CEILING LUMINAIRE RECESS MOUNTED CEILING LUMINAIRE-DIRECTIONAL RECESS MOUNTED WALL LUMINAIRE PENDANT MOUNTED LUMINAIRE TRACK LIGHTING EMERGENCY LIGHTING UNIT EXIT LIGHT, ARROWS AS INDICATED, FACES INDICATED BY SHADING SPOT / FLOOD LIGHT UNDERCABINET LIGHTING POLE MOUNTED LUMINAIRE BOLLARD SHADING INDICATES CONNECTION TO EMERGENCY SYSTEM; LS INDICATE LIFE SAFETY CIRCUIT. DESCRIPTION SYMBOL DESCRIPTION SYMBOL J SINGLE POLE SWITCH (SUBSCRIPT DENOTES SWITCHING) TWO POLE SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH KEY OPERATED SWITCH MANUAL SWITCH, HORSEPOWER RATE DIMMER SWITCH LOW VOLTAGE SWITCH THERMAL OVERLOAD SWITCH MOMENTARY CONTACT SWITCH PHOTOCELL TIME CLOCK S a S 2 S 3 S 4 S K S M S D S LV S TO S MC ABBREVIATIONS LEGEND AMPERES ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ANNUNCIATOR ABOVE RAISED FLOOR AIR SAMPLING SMOKE DETECTION AUTOMATIC TRANSFER SWITCH BELOW FINISHED GRADE MINIMUM MAIN LUGS ONLY MANUAL TRANSFER SWITCH NORMALLY CLOSED NIGHT LIGHT NORMALLY OPEN NOT TO SCALE CONDUIT CABLE TELEVISION CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION EXISTING EMERGENCY EXPLOSION PROOF EMERGENCY POWER OFF ELECTRIC WATER COOLER TRANSFORMER WEATHER PROOF VARIABLE FREQUENCY DRIVE VOLTS UNINTERRUPTABLE POWER SUPPLY UNLESS OTHERWISE NOTED UNDER GROUND UNDER FLOOR TYPICAL TRANSIENT VOLTAGE SURGE SUPPRESSER TAMPER PROOF PULL BOX OWNER FURNISHED, OWNER INSTALLED OWNER FURNISHED, CONTRACTOR INSTALLED ON CENTER NOT IN CONTRACT A-1 ONE-LINE DIAGRAM LEGEND DISCONNECT SWITCH DISCONNECT SWITCH, FUSED CIRCUIT BREAKER: L=LONG TIME PICKUP, S=SHORTTIME PICKUP; I - INSTANEOUS TRIP, G=GROUND FAULT PANELBOARD "A" EM=ENERGY METER, PM=POWER METER, CM=CIRCUIT MONITOR VOLTMETER AMMETER ENGINE GENERATOR CONTACTOR/RELAY/CAPACITOR (AS NOTED) TRANSFER SWITCH - ATS=AUTOMATIC, MTS=MANUAL GROUND FAULT INTERUPTER TRANSIENT VOLTAGE SURGE SUPPRESSER SHUNT TRIP DRAW-OUT DEVICE PLUG-IN DEVICE ELECTRICALLY OPERATED SERVICE WEATHERHEAD EQUIPMENT ENCLOSURE METER SERVICE ENTRANCE TRANSFORMER POTENTIAL TRANSFORMER CURRENT TRANSFORMER STEP DOWN TRANSFORMER, ## INDICATES KVA GROUND FUSE DESCRIPTION SYMBOL DESCRIPTION SYMBOL T## A PM V GFI M T PM A G TVSS ST EO PC EWC EPO EP EM (E) CCTV CB CATV C BFG ATS ASSD ARF ANN AFG AFF A XFMR WP VFD V UPS UON UG UF TYP TVSS TP PB OFOI OFCI OC NTS NO NL NIC NC MTS MLO MIN WIREMOLD (SURFACE RACEWAY) SHADING INDICATES EMERGENCY SYSTEM TEXT INDICATES PANEL AND CIRCUIT DESIGNATION OCCUPANCY SENSOR - CEILING MOUNTED DUAL TECHNOLOGY FIRE ALARM GROUND GROUND FAULT INTERRUPTING HAND OFF AUTOMATIC ISOLATED GROUND MAXIMUM MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION CENTER MDC MCC MCB MAX IG HOA GFI G FA DUPLEX RECEPTACLE ABOVE COUNTER a A DOUBLE DUPLEX RECEPTACLE ABOVE COUNTER LSIG TC OC OR LS MH MOUNTING HEIGHT MH OCCUPANCY SENSOR - WALL MOUNTED DUAL TECHNOLOGY OC FIRE ALARM SYSTEM LEGEND FIRE ALARM CONTROL PANEL MANUAL PULL STATION ADDRESSABLE INPUT MODULE ADDRESSABLE OUTPUT MODULE REMOTE ANNUNCIATOR PANEL GRAPHIC ZONE MAP ELEVATOR STATUS/RECALL DUCT SMOKE DETECTOR S=SUPPLY, R=RETURN DUCT DETECTOR REMOTE INDICATOR ALARM AND TEST REMOTE INDICATOR LIGHT INDICATES A FIRE ALARM DEVICE CONTROLLING A FIRE SMOKE DAMPER FLOW DETECTOR SWITCH TAMPER SWITCH MAGNETIC DOOR HOLD EMERGENCY TELEPHONE STATION (J=JACK, H=HANDSET) FIRE ALARM STROBE (cd= CANDELLA RATING 15, 30, 75, 110) AUDIBLE DEVICE (H=HORN, S=SPEAKER, C=CHIME) DESCRIPTION SYMBOL DESCRIPTION FACP FAA GZM ESR P F RTS M AOM H15cd H 15cd J FSD SYMBOL AIM SMOKE DETECTOR WITH CO DETECTION (P=PHOTOELECTRIC) HEAT DETECTOR (F=FIXED, BLANK = RATE OF RISE) AUDIBLE/VISUAL DEVICE (H=HORN, S=SPEAKER, C=CHIME) R SEH Project Checked By Drawn By Project Status Issue Date This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH. Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH. Architect/ Civil Engineer/ Structural Landscape Architect Mechanical Engineer Electrical Engineer Owner Short Elliott Hendrickson, Inc. 2000 South Colorado Boulevard Tower One, Suite 6000 Denver, Colorado 80222 720.540.6800 Short Elliott Hedrickson, Inc. All Rights Reserved COPYRIGHT © 2019 Technology BCER Engineering Inc 5420 Ward Rd Arvada, CO 80002 303.422.7400 City of Greeley 1000 10th Street Greeley, Colorado 80631 970.350.9777 DHM DESIGN 900 South Broadway Denver, Colorado 80209 303.892.5566 The Ballard Group 2525 South Wadsworth Blvd, Suite 200 Lakewood, Colorado 80227 303.988.4514 CMO Consuling Engineers, LLC 11646 Sun Bear Trail Golden, Colorado 80403 303.875.4037 10/17/2019 5:48:42 PM ELECTRICAL LEGEND E 001 GREELEY FIRE STATION #2 2301 Reservoir Rd, Greeley, CO 80634 18323.02 City of Greeley 100% CONSTRUCTION DOCUMENTS 8/28/2019 GENERAL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. ALL ELECTRICAL WORK PERFORMED UNDER THIS CONTRACT SHALL CONFORM WITH LATEST EDITIONS OF THE NATIONAL ELECTRICAL CODE, UNIFORM BUILDING CODE OR INTERNATIONAL BUILDING CODE, LOCAL BUILDING AND FIRE DEPARTMENT REQUIREMENTS. ELECTRICAL CONTRACTOR SHALL FULLY COORDINATE WITH OWNER REPRESENTATIVES. PERFORM WORK IN ACCORDANCE WITH REQUIREMENTS OF OWNER REPRESENTATIVES. ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER OF ANY CHANGES REQUIRED BY THE BUILDING MANAGEMENT AND TENANT REPRESENTATIVES. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF ELECTRICAL WORK. LOCATIONS ARE APPROXIMATE AND SHALL BE SUBJECT TO MINOR MODIFICATIONS AS DIRECTED BY THE GENERAL CONTRACTOR AND OWNER REPRESENTATIVES. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE EXACT FITTING OF ALL MATERIALS, EQUIPMENT, ETC., IN THE BUILDING AND TENANT SPACE. ALL DIMENSIONS SHALL BE VERIFIED ON THE JOB. ELECTRICAL CONTRACTOR SHALL CUT, CHANNEL, CHASE, AND/OR DRILL FLOORS, WALLS, PARTITIONS, CEILINGS, OR OTHER SURFACES AS REQUIRED FOR INSTALLATION, UPPORT, ANCHORAGE, ETC., OF WORK. PROVIDE X-RAY OF FLOOR PRIOR TO CORE DRILLS. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SUBSEQUENT PATCHING WORK. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. PRIOR TO SUBMITTING BIDS, THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO VERIFY EXISTING ELECTRICAL EQUIPMENT CONDITIONS AND DIFFICULTIES THAT WILL AFFECT EXECUTION OF THE WORK. FIELD VERIFY QUANTITIES OF EXISTING LIGHT FIXTURES, ELECTRICAL DEVICES, COMMUNICATION DEVICES, FIRE ALARM DEVICES, AND ELECTRICAL EQUIPMENT. NOTIFY THE ARCHITECT AND ENGINEER OF ANY EXISTING CONDITIONS, WHICH MODIFY THE SCOPE OF WORK AS SHOWN ON THE CONSTRUCTION DOCUMENTS. SUBMISSION OF A BID PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR MOBILIZATION, LABOR, EQUIPMENT, AND/OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CMO CONSULTING ENGINEERS, LLC IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. FIELD LOCATE EXISTING UNDERGROUND PUBLIC AND OWNER UTILITIES OF ALL TRADES AND BUILDING GROUNDING/LIGHTNING PROTECTION SYSTEMS PRIOR TO ANY EXCAVATION. REPLACE OR REPAIR DAMAGED UTILITIES AND GROUNDING/LIGHTNING PROTECTION SYSTEMS TO ORIGINAL CONDITION. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. VERIFY RATED WALL LOCATIONS ON ARCHITECTURAL DRAWINGS. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. REFER TO ARCHITECTURAL AND MECHANICAL EQUIPMENT DRAWINGS FOR EXACT LOCATIONS OF ELECTRICAL DEVICES AND LIGHT FIXTURES. DO NOT SCALE FROM THE ELECTRICAL PLANS. ADDITIONAL ELECTRICAL REQUIREMENTS ON ARCHITECTURAL PLANS, KITCHEN EQUIPMENT PLANS, AND MECHANICAL PLANS SHALL BE INCLUDED IN THE ELECTRICAL CONTRACTOR'S BID. DEMOLITION OF ANY ELECTRICAL AND COMMUNICATIONS CONDUIT, WIRING, CABLING, OR DEVICE MEANS TO REMOVE IN ITS ENTIRETY. REMOVE UNUSED CONDUITS FROM CEILING SPACES IN AREAS OF WORK. RETURN UNUSED ELECTRICAL EQUIPMENT AND LIGHT FIXTURES TO BUILDING MANAGEMENT FOR STORAGE AND/OR REMOVAL FROM SITE AS DIRECTED BY OWNERS. WHERE REMODELING INTERFERES WITH EXISTING CIRCUITS AND EQUIPMENT WHICH ARE NOT TO BE REMOVED OR ARE OUTSIDE OF THE PROJECT AREA, SUCH CIRCUITS AND EQUIPMENT SHALL BE REWORKED AND RELOCATED AS REQUIRED TO COMPLETE THE PROJECT. MINIMUM WORKING CLEARANCES PER THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE SHALL BE PROVIDED AROUND AND IN FRONT OF ALL ELECTRICAL EQUIPMENT. ELECTRICAL CONTRACTOR SHALL MAINTAIN ON THE JOB AN UP TO DATE SET OF WORKING DRAWINGS, MARKED UP TO SHOW ELECTRICAL SYSTEMS AS INSTALLED. PROVIDE TENANT REPRESENTATIVES WITH ONE SET OF REPRODUCIBLES WITH "AS BUILT" PROJECT RECORD INFORMATION CLEARLY INDICATED. ELECTRICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LOCAL FEES, PERMITS, AND SERVICES OF INSPECTION AUTHORITIES REQUIRED BY ELECTRICAL WORK FOR THIS ELECTRICAL CONSTRUCTION. PROVIDE TYPED, UPDATED, COMPLETE AND ACCURATE PANELBOARD CIRCUIT DIRECTORIES AT THE COMPLETION OF WORK. CLEAN EXPOSED PANELBOARD SURFACES AND CHECK TIGHTNESS OF ELECTRICAL CONNECTIONS. REPLACE DAMAGED CIRCUIT BREAKERS AS REQUIRED AND ROVIDE FILLER PLATES FOR VACANT SPACES. PROVIDE UPDATED LABELING OF ALL NEW AND RELOCATED ELECTRICAL EQUIPMENT IN SCOPE OF WORK INCLUDING, BUT NOT LIMITED TO, ENGINE GENERATOR SYSTEMS, TRANSFER SWITCHES, TRANSFORMERS, SWITCHGEAR, SWITCHBOARDS, PANELBOARDS, MOTOR CONTROL CENTERS, AND DISCONNECTS TO INDICATE THE AMPERE RATING, VOLTAGE RATING, PHASE, CONDUCTOR COLOR CODING WITHIN THE EQUIPMENT AND APPLICABLE AIC RATING. ALL NEW AND MODIFIED ELECTRICAL EQUIPMENT, SUCH AS SWITCHBOARDS, PANELBOARDS, INDUSTRIAL CONTROL PANELS, METER SOCKET ENCLOSURES, AND MOTOR CONTROL CENTERS, THAT ARE LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS. THE MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE EQUIPMENT PER NEC ARTICLE 110.16. DEFERRED SUBMITTAL LIST: FIRE ALARM COORDINATION STUDY WITH ARC FLASH ANALYSIS Luminaire Schedule Type Description Lamp Load Manufactur er Catalog # Ballast Voltage Finish Mounting Depth A3 2'x4' RECESSED LED ARCHITECTURAL TROFFER. 10% DIMMING LED 47 VA LITHONIA LIGHTING 2ALL4 60L MVOLT EZ1 LP835 120 V WHITE RECESS 0' - 6" CF SURFACE MOUNTED 48" CEILING FAN WITH LIGHTS LED 33 VA CANARM LAWSON CF48L-4 120 V PEWTER SURFACE D3 6" DIAMETER LED RECESSED DOWNLIGHT. HALL AND TLTS LED 1500 LUMENS 19 VA LITHONIA, COLUMBIA, METALUX EVO 35/15 6WR MD LD 120 V WHITE RECESSED 0' - 6" D3E 6" DIAMETER LED RECESSED DOWNLIGHT WITH BATTERY BACKUP. HALL AND TLTS LED 1500 LUMENS 19 VA LITHONIA, COLUMBIA, METALUX EVO 35/15 6WR MD LD 120 V RECESSED 0' - 6" D4 6" DIAMETER LED RECESSED DOWNLIGHT. WET LOCATION LED 1500 LUMENS 30 VA LITHONIA, COLUMBIA, METALUX LDN6 30/25 L06WR 120 V WHITE RECESSED 0' - 6" D4E 6" DIAMETER LED RECESSED DOWNLIGHT. WET LOCATION LED 1500 LUMENS 30 VA LITHONIA, COLUMBIA, METALUX LDN6 30/35 L06WR EM 120 V WHITE RECESSED 0' - 6" DS 6" DIAMETER LED RECESSED DOWNLIGHT - SHOWERS AND STEAM ROOM. WET LOCATION AND IP65 RATED. LED 1000 LUMENS 12 VA LITHONIA, COLUMBIA, METALUX EVO 35/10 6DFR 120 V WHITE RECESSED 0' - 6" EP2 EXTERIOR LIGHT POLE - DOUBLE HEAD 25' POLE LED 280 VA LITHONIA, COLUMBIA, METALUX DSX2 LED P1 30K T3M 120 V DK BRONZE 30" BASE 0' - 0" ES1 4" DIA IN GRADE LED ARCHITECTURAL LIGHT FOR FLAG POLE. SS FINISH LED 50 VA HYDREL OR EQUILIVANT M720C SS LED P3 40K MVOLT NFL FLC 120 V IN GRADE EW1 WALL LIGHT - WET LOCATION LABEL - MOTION SENSOR AND PHOTOCEL LED - 3500 LUMEN 29 VA LITHONIA, COLUMBIA, METALUX KAWX LED P1 R4 120 PIR DDBXD 120 V DK BRONZE SURFACE EW3 WALL LIGHT - WET LOCATION LABEL. MOTION SENSOR AND PHOTOCEL LED 29 VA LITHONIA, COLUMBIA, METALUX KAWX LED P1 R2 120 PIR DDBXD 120 V DK BRONZE SURFACE R1 KITCHEN PENDANT - 14" DIAMETER LED 72 VA ARTEMIDE OR EQUILIVANT NUR 120 V POLISHED WHITE PENDANT S4S 2'x4' SURFACE MOUNTED LED HIGH BAY TROFFER, LENSED, DIMMING WITH 306 MOTION SENSOR AND PHOTOCEL, LED 18000 LUMEN 146 VA LITHONIA, COLUMBIA, METALUX IBH 18000LM SD080 120 0Z10 35K 80CRI 120 V WHITE SURFACE ST1 WALL STEP LIGHT LED 4 VA WAC OR EQUILIVANT WL LED 100 C BBR 120 V DK BRONZE SURFACE ST4 4' LINEAR LED STRIP LIGHT. FROSTED DROP LENS. LED 5000 LUMENS 41 VA LITHONIA, COLUMBIA, METALUX ZLIN L48 5000LM FST 120 35K 80CRI 120 V WHITE SURFACE ST8 8' LINEAR LED STRIP LIGHT. FROSTED DROP LENS LED-10000 LUMEN 82 VA LITHONIA, COLUMBIA, METALUX TZL1D L96 10000LM FST 120 35K 80CRI WH 120 V WHITE SURFACE T2 2'X2' RECESSED FLAT PANEL LED LED-4000LM 35 VA LITHONIA, COLUMBIA, METALUX EPANL 2234L 35K 120 V WHITE RECESSED 0' - 5" UC 30" UNDERCABINET FIXTURE LED 13 VA JUNO OR EQUILIVANT UPS30 35K 120 V BLACK SURFACE W1 36" X 4" TOILET ROOM ABOVE MIRROR FIXTURE LED 25 VA LITHONIA, COLUMBIA, METALUX FMVCSL 36IN 35K 120 V BRUSHED NICKEL SURFACE W2 WALL LIGHT - HIGH ABUSE WET LOCATION. POLYCARBONATE LENS LED 30 VA FAILSAFE OR EQUILIVANT FW 1212 2500 35 UNV CP RA EOD1 LGBZ 120 V DK BRONZE SURFACE X1 UNIVERSAL LED THERMOPLASTIC EXIT SIGNAGE, BATTERY BACK DUAL MOUNTING OPTIONS, GREEN LETTERS CEILING MOUNTED SINGLE SIDED EXIT LIGHT, GREEN LETTERS LED 3 VA LITHONIA, COLUMBIA, METALUX LQC-2-G-UNIVERSAL MOUNT 120 V WHITE UNIVERSAL MOUNT X2 CEILING MOUNTED, DOUBLE SIDED EXIT LIGHT, GREEN LETTERS WITH SELF DIAGNOSTIC BATTERY LED 5 VA LITHONIA LIGHTING LQC-2-G 120 V WHITE SURFACE Mechanical Equipment Schedule Key # Item HP FLA Load Eq Load (VA) Voltage Feeders Protection Notes Wire Ground Conduit Breake r Disconnect Fuse ACCU 1 CONDENSING UNIT 0 18 A 3744 VA 208V 1ph 2#10 #10G 3/4" 30 A 30 A 30 A B 1 BOILER 0 12 A 1440 VA 120V 1ph 2#12 #12G 3/4” 20 A S B 2 BOILER 0 12 A 1440 VA 120V 1ph 2#12 #12G 3/4” 20 A S CF 1 CEILING FAN 0 10 A 1200 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A CP 1 CIRC PUMP 0.2 0 A 667 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A CP 2 CIRC PUMP 0.2 0 A 667 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A CPR 1 COMPRESSOR 7.5 0 A 8764 VA 208V 3ph 3#8 #10G 3/4” 45 A 60 A 40 A CPR 2 COMPRESSOR 15 0 A 16732 VA 208V 3ph 3#4 #8G 1-1/4” 90 A 100 A 70 A CUH 1 CABINET UNIT HEATER 0.1 0 A 506 VA 120V 1ph 2#12 #12G 3/4” 20 A S DAC 1 SPLIT SYSTEM AIR COND 0 13 A 2705 VA 208V 1ph 2#10 #10G 3/4" 30 A 30 A 30 A DR 1 DRYER 0 0 A 5000 VA 208V 1ph 2#8 #10G 3/4” 35 A EF 1 EXHAUST FAN 0.75 0 A 1587 VA 208V 1ph 2#12 #12G 3/4” 20 A S EF 2 EXHAUST FAN 0.75 0 A 1587 VA 208V 1ph 2#12 #12G 3/4” 20 A S EF 3 EXHAUST FAN 0.1 0 A 506 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 4 EXHAUST FAN 0.15 0 A 506 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 5 EXHAUST FAN 0.15 0 A 506 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 6 EXHAUST FAN 0.1 0 A 506 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 7 EXHAUST FAN 0 0 A 20 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 8 EXHAUST FAN 0 0 A 20 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 9 EXHAUST FAN 0 0 A 20 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 10 EXHAUST FAN 0 0 A 20 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 11 EXHAUST FAN 0 0 A 20 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 12 EXHAUST FAN 0 0 A 16 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 13 EXHAUST FAN 0 0 A 16 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 14 EXHAUST FAN 0 0 A 16 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 15 EXHAUST FAN 0 0 A 16 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EF 16 EXHAUST FAN 0.5 0 A 1127 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 A EQ 1 BAY EQUIPMENT 0 0 A 7500 VA 208V 1ph 2#6 #10G 1” 50 A EUH 1 UNIT HEATER 0 0 A 3000 VA 208V 1ph 2#12 #12G 3/4” 20 A S EX 1 EXTRACTOR 0 0 A 7500 VA 208V 1ph 2#6 #10G 1” 50 A GUH 1 UNIT HEATER 0.5 0 A 1127 VA 120V 1ph 2#12 #12G 3/4” 20 A S GUH 2 UNIT HEATER 0.75 0 A 1587 VA 120V 1ph 2#12 #12G 3/4” 25 A S GUH 3 UNIT HEATER 0.3 0 A 832 VA 120V 1ph 2#12 #12G 3/4” 20 A S HD 1 KITCHEN HOOD 0 0 A 14 VA 120V 1ph 2#12 #12G 3/4” 20 A S HR 1 HOSE REEL 5 0 A 6055 VA 208V 3ph 3#10 #10G 3/4” 30 A 30 A 30 A P 1 PUMP 0 0 A 607 VA 208V 1ph 2#12 #12G 3/4” 20 A S P 2 PUMP 0 0 A 607 VA 208V 1ph 2#12 #12G 3/4” 20 A S PE 1 POWER EXHAUST 0 7 A 2522 VA 208V 3ph 3#12 #12G 3/4” 15 A 30 A 10 A PE 2 POWER EXHAUST 0 11 A 3963 VA 208V 3ph 3#12 #12G 3/4” 15 A 30 A 15 A PE 3 POWER EXHAUST 0 7 A 2522 VA 208V 3ph 3#12 #12G 3/4” 15 A 30 A 10 A RH 1 RADIENT HEATER 0 1 A 120 VA 120V 1ph 2#12 #12G 3/4” 20 A S RH 2 RADIENT HEATER 0 1 A 120 VA 120V 1ph 2#12 #12G 3/4” 20 A S RH 3 RADIENT HEATER 0 1 A 120 VA 120V 1ph 2#12 #12G 3/4” 20 A S RH 4 RADIENT HEATER 0 1 A 120 VA 120V 1ph 2#12 #12G 3/4” 20 A S RTU 1 ROOF TOP UNIT 0 45 A 16212 VA 208V 3ph 3#4 #10G 1-1/4” 60 A 60 A 60 A RTU 2 ROOF TOP UNIT 0 75 A 27020 VA 208V 3ph 3#2 #8G 1-1/4” 100 A 100 A 100 A RTU 3 ROOF TOP UNIT 0 45 A 16212 VA 208V 3ph 3#4 #10G 1-1/4” 60 A 60 A 60 A UH 1 UNIT HEATER 0 1 A 160 VA 120V 1ph 2#12 #12G 3/4” 20 A S REVISIONS Rev. # Description Date 1 Addendum #2 10/18/2019

Upload: others

Post on 07-Jun-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: C:UsersCharleneDesktopCMOProjects 9190228 greeley fire

POWER LEGENDSINGLE RECEPTACLE

DUPLEX RECEPTACLE

DOUBLE DUPLEX RECEPTACLE

DUPLEX RECEPTACLE, HALF SWITCHED

DUPLEX RECEPTACLE, CEILING MOUNTED

DUPLEX RECEPTACLE, FLOOR MOUNTED

DOUBLE DUPLEX RECEPTACLE, FLOOR MOUNTED

SPECIAL RECEPTACLE

SPECIAL RECEPTACLE, FLOOR MOUNTED

JUNCTION BOX, WALL OR CEILING MOUNTED

DISCONNECT SWTICH (NON-FUSED)

DISCONNECT SWITCH (FUSED)

COMBINATION STARTER/DISCONNET

ELECTRICAL PANELBOARD OR OTHERCABINET AS NOTED

PLUG MOLD (MULTI-OUTLET ASSEMBLY)

CONNECTION TO EQUIPMENT

CONDUIT EXPOSEDCONDUIT TURNING DOWN

CONDUIT TURNING UP

CONDUIT CAPPED

MAIN SWITCHBOARD/DISTRIBUTION CENTER

CURRENT TRANSFORMER

GENERATOR ANNUNCIATOR PANEL

DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL

CLG

J

M

WM

T

CT

GANN

MOTOR

CONDUIT CONCEALED

GROUND BAR

TRANSFORMER

THERMOSTAT

LIGHTING LEGENDRECESSED FLUORESCENT LUMINAIRE, LAY-IN GRID CEILING, LOWERCASE SCRIPT INDICATES SWITCHING; UPPERCASE INDICATES LUMINAIRE TYPE.

RECESSED FLUORESCENT LUMINAIRE, FLANGED

SURFACE MOUNTED LUMINAIRE

SURFACE OR PENDANT MOUNTED STRIP

SURFACE MOUNTED WALL LUMINAIRE

PENDANT MOUNTED LINEAR LUMINAIRE

RECESSED DIRECT/INDIRECT LUMINAIRE

SURFACE MOUNTED CEILING LUMINAIRE

SURFACE MOUNTED WALL LUMINAIRE

RECESS MOUNTED CEILING LUMINAIRE

RECESS MOUNTED CEILING LUMINAIRE-DIRECTIONAL

RECESS MOUNTED WALL LUMINAIRE

PENDANT MOUNTED LUMINAIRE

TRACK LIGHTING

EMERGENCY LIGHTING UNITEXIT LIGHT, ARROWS AS INDICATED, FACES INDICATED BY SHADING

SPOT / FLOOD LIGHT

UNDERCABINET LIGHTING

POLE MOUNTED LUMINAIRE

BOLLARDSHADING INDICATES CONNECTION TO EMERGENCY SYSTEM; LS INDICATE LIFE SAFETY CIRCUIT.

DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL

J

SINGLE POLE SWITCH (SUBSCRIPT DENOTES SWITCHING)TWO POLE SWITCHTHREE-WAY SWITCH

FOUR-WAY SWITCH

KEY OPERATED SWITCH

MANUAL SWITCH, HORSEPOWER RATE

DIMMER SWITCH

LOW VOLTAGE SWITCH

THERMAL OVERLOAD SWITCH

MOMENTARY CONTACT SWITCH

PHOTOCELL

TIME CLOCK

SaS2S3S4SKSMSDSLV

STO

SMC

ABBREVIATIONS LEGENDAMPERESABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

ANNUNCIATOR

ABOVE RAISED FLOOR

AIR SAMPLING SMOKE DETECTION

AUTOMATIC TRANSFER SWITCH

BELOW FINISHED GRADE

MINIMUM

MAIN LUGS ONLY

MANUAL TRANSFER SWITCH

NORMALLY CLOSED

NIGHT LIGHT

NORMALLY OPEN

NOT TO SCALE

CONDUIT

CABLE TELEVISION

CIRCUIT BREAKER

CLOSED CIRCUIT TELEVISION

EXISTING

EMERGENCY

EXPLOSION PROOF

EMERGENCY POWER OFF

ELECTRIC WATER COOLERTRANSFORMER

WEATHER PROOF

VARIABLE FREQUENCY DRIVE

VOLTS

UNINTERRUPTABLE POWER SUPPLY

UNLESS OTHERWISE NOTED

UNDER GROUND

UNDER FLOOR

TYPICAL

TRANSIENT VOLTAGE SURGE SUPPRESSER

TAMPER PROOF

PULL BOX

OWNER FURNISHED, OWNER INSTALLED

OWNER FURNISHED, CONTRACTOR INSTALLED

ON CENTER

NOT IN CONTRACT

A-1

ONE-LINE DIAGRAM LEGENDDISCONNECT SWITCH

DISCONNECT SWITCH, FUSED

CIRCUIT BREAKER: L=LONG TIME PICKUP, S=SHORTTIME PICKUP; I - INSTANEOUS TRIP, G=GROUND FAULT

PANELBOARD "A"

EM=ENERGY METER, PM=POWER METER, CM=CIRCUIT MONITOR

VOLTMETER

AMMETER

ENGINE GENERATOR

CONTACTOR/RELAY/CAPACITOR (AS NOTED)

TRANSFER SWITCH - ATS=AUTOMATIC, MTS=MANUAL

GROUND FAULT INTERUPTER

TRANSIENT VOLTAGE SURGE SUPPRESSER

SHUNT TRIP

DRAW-OUT DEVICE

PLUG-IN DEVICE

ELECTRICALLY OPERATED

SERVICE WEATHERHEAD

EQUIPMENT ENCLOSURE

METER

SERVICE ENTRANCE TRANSFORMER

POTENTIAL TRANSFORMER

CURRENT TRANSFORMER

STEP DOWN TRANSFORMER, ## INDICATES KVA

GROUNDFUSE

DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL

T##

A

PM

V

GFI

M

T

PM

A

G

TVSS

ST

EO

PC

EWC

EPO

EP

EM

(E)

CCTV

CB

CATV

C

BFG

ATS

ASSD

ARF

ANN

AFG

AFFA

XFMR

WP

VFD

V

UPS

UON

UG

UF

TYP

TVSS

TP

PB

OFOI

OFCI

OCNTS

NO

NL

NIC

NC

MTS

MLO

MIN

WIREMOLD (SURFACE RACEWAY)

SHADING INDICATES EMERGENCY SYSTEMTEXT INDICATES PANEL AND CIRCUIT DESIGNATION

OCCUPANCY SENSOR - CEILING MOUNTEDDUAL TECHNOLOGY

FIRE ALARM

GROUND

GROUND FAULT INTERRUPTING

HAND OFF AUTOMATIC

ISOLATED GROUND

MAXIMUM

MAIN CIRCUIT BREAKER

MOTOR CONTROL CENTER

MAIN DISTRIBUTION CENTERMDC

MCC

MCB

MAX

IG

HOA

GFI

G

FA

DUPLEX RECEPTACLE ABOVE COUNTER

aA

DOUBLE DUPLEX RECEPTACLE ABOVE COUNTER

LSIG

TC

OC OR

LS

MH

MOUNTING HEIGHTMH

OCCUPANCY SENSOR - WALL MOUNTEDDUAL TECHNOLOGY

OC

FIRE ALARM SYSTEM LEGENDFIRE ALARM CONTROL PANEL MANUAL PULL STATION

ADDRESSABLE INPUT MODULE

ADDRESSABLE OUTPUT MODULE

REMOTE ANNUNCIATOR PANEL

GRAPHIC ZONE MAP

ELEVATOR STATUS/RECALL

DUCT SMOKE DETECTOR S=SUPPLY, R=RETURN

DUCT DETECTOR REMOTE INDICATOR ALARM AND TEST

REMOTE INDICATOR LIGHT

INDICATES A FIRE ALARM DEVICE CONTROLLING A FIRE SMOKE DAMPER

FLOW DETECTOR SWITCH

TAMPER SWITCH

MAGNETIC DOOR HOLD

EMERGENCY TELEPHONE STATION (J=JACK, H=HANDSET)

FIRE ALARM STROBE (cd= CANDELLA RATING 15, 30, 75, 110)

AUDIBLE DEVICE (H=HORN, S=SPEAKER, C=CHIME)

DESCRIPTIONSYMBOL DESCRIPTION

FACP

FAA

GZM

ESR

P

F

RTS

M

AOM

H15cd

H

15cd

J

FSD

SYMBOL

AIM

SMOKE DETECTOR WITH CO DETECTION(P=PHOTOELECTRIC)HEAT DETECTOR (F=FIXED, BLANK = RATE OF RISE)

AUDIBLE/VISUAL DEVICE (H=HORN, S=SPEAKER, C=CHIME)

R

SEH ProjectChecked ByDrawn By

Project Status Issue Date

This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.

Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Shor

t Ellio

tt Hed

ricks

on, In

c.Al

l Righ

ts Re

serve

d

COPY

RIGH

T ©

2019

TechnologyBCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

DHM DESIGN900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group2525 South Wadsworth Blvd, Suite 200Lakewood, Colorado 80227303.988.4514

CMO Consuling Engineers, LLC11646 Sun Bear TrailGolden, Colorado 80403303.875.4037

10/17

/2019

5:48

:42 P

M

ELECTRICAL LEGEND

E001

GREE

LEY

FIRE

STA

TION

#2

2301

Res

ervo

ir Rd,

Gree

ley, C

O 80

634

18323.02

City

of Gr

eeley

100% CONSTRUCTIONDOCUMENTS

8/28/2019

GENERAL NOTES:1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY.

ALL ELECTRICAL WORK PERFORMED UNDER THIS CONTRACT SHALL CONFORM WITH LATEST EDITIONS OF THE NATIONAL ELECTRICAL CODE, UNIFORM BUILDING CODE OR INTERNATIONAL BUILDING CODE, LOCAL BUILDING AND FIRE DEPARTMENT REQUIREMENTS.

ELECTRICAL CONTRACTOR SHALL FULLY COORDINATE WITH OWNER REPRESENTATIVES. PERFORM WORK IN ACCORDANCE WITH REQUIREMENTS OF OWNER REPRESENTATIVES. ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER OF ANY CHANGES REQUIRED BY THE BUILDING MANAGEMENT AND TENANT REPRESENTATIVES.

THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF ELECTRICAL WORK. LOCATIONS ARE APPROXIMATE AND SHALL BE SUBJECT TO MINOR MODIFICATIONS AS DIRECTED BY THE GENERAL CONTRACTOR AND OWNER REPRESENTATIVES. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE EXACT FITTING OF ALL MATERIALS, EQUIPMENT, ETC., IN THE BUILDING AND TENANT SPACE. ALL DIMENSIONS SHALL BE VERIFIED ON THE JOB. ELECTRICAL CONTRACTOR SHALL CUT, CHANNEL, CHASE, AND/OR DRILL FLOORS, WALLS, PARTITIONS, CEILINGS, OR OTHER SURFACES AS REQUIRED FOR INSTALLATION, UPPORT, ANCHORAGE, ETC., OF WORK. PROVIDE X-RAY OF FLOOR PRIOR TO CORE DRILLS. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SUBSEQUENT PATCHING WORK.

A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

PRIOR TO SUBMITTING BIDS, THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO VERIFY EXISTING ELECTRICAL EQUIPMENT CONDITIONS AND DIFFICULTIES THAT WILL AFFECT EXECUTION OF THE WORK. FIELD VERIFY QUANTITIES OF EXISTING LIGHT FIXTURES, ELECTRICAL DEVICES, COMMUNICATION DEVICES, FIRE ALARM DEVICES, AND ELECTRICAL EQUIPMENT. NOTIFY THE ARCHITECT AND ENGINEER OF ANY EXISTING CONDITIONS, WHICH MODIFY THE SCOPE OF WORK AS SHOWN ON THE CONSTRUCTION DOCUMENTS. SUBMISSION OF A BID PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR MOBILIZATION, LABOR, EQUIPMENT, AND/OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED.

PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK.

EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CMO CONSULTING ENGINEERS, LLC IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS.

FIELD LOCATE EXISTING UNDERGROUND PUBLIC AND OWNER UTILITIES OF ALL TRADES AND BUILDING GROUNDING/LIGHTNING PROTECTION SYSTEMS PRIOR TO ANY EXCAVATION. REPLACE OR REPAIR DAMAGED UTILITIES AND GROUNDING/LIGHTNING PROTECTION SYSTEMS TO ORIGINAL CONDITION.

INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED.

DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER.

FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. VERIFY RATED WALL LOCATIONS ON ARCHITECTURAL DRAWINGS.

PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS.

REFER TO ARCHITECTURAL AND MECHANICAL EQUIPMENT DRAWINGS FOR EXACT LOCATIONS OF ELECTRICAL DEVICES AND LIGHT FIXTURES. DO NOT SCALE FROM THE ELECTRICAL PLANS. ADDITIONAL ELECTRICAL REQUIREMENTS ON ARCHITECTURAL PLANS, KITCHEN EQUIPMENT PLANS, AND MECHANICAL PLANS SHALL BE INCLUDED IN THE ELECTRICAL CONTRACTOR'S BID.

DEMOLITION OF ANY ELECTRICAL AND COMMUNICATIONS CONDUIT, WIRING, CABLING, OR DEVICE MEANS TO REMOVE IN ITS ENTIRETY. REMOVE UNUSED CONDUITS FROM CEILING SPACES IN AREAS OF WORK. RETURN UNUSED ELECTRICAL EQUIPMENT AND LIGHT FIXTURES TO BUILDING MANAGEMENT FOR STORAGE AND/OR REMOVAL FROM SITE AS DIRECTED BY OWNERS.

WHERE REMODELING INTERFERES WITH EXISTING CIRCUITS AND EQUIPMENT WHICH ARE NOT TO BE REMOVED OR ARE OUTSIDE OF THE PROJECT AREA, SUCH CIRCUITS AND EQUIPMENT SHALL BE REWORKED AND RELOCATED AS REQUIRED TO COMPLETE THE PROJECT.

MINIMUM WORKING CLEARANCES PER THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE SHALL BE PROVIDED AROUND AND IN FRONT OF ALL ELECTRICAL EQUIPMENT.

ELECTRICAL CONTRACTOR SHALL MAINTAIN ON THE JOB AN UP TO DATE SET OF WORKING DRAWINGS, MARKED UP TO SHOW ELECTRICAL SYSTEMS AS INSTALLED. PROVIDE TENANT REPRESENTATIVES WITH ONE SET OF REPRODUCIBLES WITH "AS BUILT" PROJECT RECORD INFORMATION CLEARLY INDICATED. ELECTRICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LOCAL FEES, PERMITS, AND SERVICES OF INSPECTION AUTHORITIES REQUIRED BY ELECTRICAL WORK FOR THIS ELECTRICAL CONSTRUCTION.

PROVIDE TYPED, UPDATED, COMPLETE AND ACCURATE PANELBOARD CIRCUIT DIRECTORIES AT THE COMPLETION OF WORK. CLEAN EXPOSED PANELBOARD SURFACES AND CHECK TIGHTNESS OF ELECTRICAL CONNECTIONS. REPLACE DAMAGED CIRCUIT BREAKERS AS REQUIRED AND ROVIDE FILLER PLATES FOR VACANT SPACES.

PROVIDE UPDATED LABELING OF ALL NEW AND RELOCATED ELECTRICAL EQUIPMENT IN SCOPE OF WORK INCLUDING, BUT NOT LIMITED TO, ENGINE GENERATOR SYSTEMS, TRANSFER SWITCHES, TRANSFORMERS, SWITCHGEAR, SWITCHBOARDS, PANELBOARDS, MOTOR CONTROL CENTERS, AND DISCONNECTS TO INDICATE THE AMPERE RATING, VOLTAGE RATING, PHASE, CONDUCTOR COLOR CODING WITHIN THE EQUIPMENT AND APPLICABLE AIC RATING.

ALL NEW AND MODIFIED ELECTRICAL EQUIPMENT, SUCH AS SWITCHBOARDS, PANELBOARDS, INDUSTRIAL CONTROL PANELS, METER SOCKET ENCLOSURES, AND MOTOR CONTROL CENTERS, THAT ARE LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS. THE MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE EQUIPMENT PER NEC ARTICLE 110.16.

DEFERRED SUBMITTAL LIST:FIRE ALARMCOORDINATION STUDY WITH ARC FLASH ANALYSIS

Luminaire Schedule

Type Description Lamp LoadManufactur

er Catalog #BallastVoltage Finish Mounting Depth

A3 2'x4' RECESSED LED ARCHITECTURAL TROFFER. 10%DIMMING

LED 47 VA LITHONIALIGHTING

2ALL4 60L MVOLT EZ1 LP835 120 V WHITE RECESS 0' - 6"

CF SURFACE MOUNTED 48" CEILING FAN WITH LIGHTS LED 33 VA CANARM LAWSON CF48L-4 120 V PEWTER SURFACED3 6" DIAMETER LED RECESSED DOWNLIGHT. HALL AND

TLTSLED 1500LUMENS

19 VA LITHONIA,COLUMBIA,METALUX

EVO 35/15 6WR MD LD 120 V WHITE RECESSED 0' - 6"

D3E 6" DIAMETER LED RECESSED DOWNLIGHT WITHBATTERY BACKUP. HALL AND TLTS

LED 1500LUMENS

19 VA LITHONIA,COLUMBIA,METALUX

EVO 35/15 6WR MD LD 120 V RECESSED 0' - 6"

D4 6" DIAMETER LED RECESSED DOWNLIGHT. WETLOCATION

LED 1500LUMENS

30 VA LITHONIA,COLUMBIA,METALUX

LDN6 30/25 L06WR 120 V WHITE RECESSED 0' - 6"

D4E 6" DIAMETER LED RECESSED DOWNLIGHT. WETLOCATION

LED 1500LUMENS

30 VA LITHONIA,COLUMBIA,METALUX

LDN6 30/35 L06WR EM 120 V WHITE RECESSED 0' - 6"

DS 6" DIAMETER LED RECESSED DOWNLIGHT - SHOWERSAND STEAM ROOM. WET LOCATION AND IP65 RATED.

LED 1000LUMENS

12 VA LITHONIA,COLUMBIA,METALUX

EVO 35/10 6DFR 120 V WHITE RECESSED 0' - 6"

EP2 EXTERIOR LIGHT POLE - DOUBLE HEAD 25' POLE LED 280 VA LITHONIA,COLUMBIA,METALUX

DSX2 LED P1 30K T3M 120 V DK BRONZE 30" BASE 0' - 0"

ES1 4" DIA IN GRADE LED ARCHITECTURAL LIGHT FOR FLAGPOLE. SS FINISH

LED 50 VA HYDREL OREQUILIVANT

M720C SS LED P3 40K MVOLTNFL FLC

120 V IN GRADE

EW1 WALL LIGHT - WET LOCATION LABEL - MOTION SENSORAND PHOTOCEL

LED - 3500LUMEN

29 VA LITHONIA,COLUMBIA,METALUX

KAWX LED P1 R4 120 PIRDDBXD

120 V DK BRONZE SURFACE

EW3 WALL LIGHT - WET LOCATION LABEL. MOTION SENSORAND PHOTOCEL

LED 29 VA LITHONIA,COLUMBIA,METALUX

KAWX LED P1 R2 120 PIRDDBXD

120 V DK BRONZE SURFACE

R1 KITCHEN PENDANT - 14" DIAMETER LED 72 VA ARTEMIDE OREQUILIVANT

NUR 120 V POLISHEDWHITE

PENDANT

S4S 2'x4' SURFACE MOUNTED LED HIGH BAY TROFFER,LENSED, DIMMING WITH 306 MOTION SENSOR AND

PHOTOCEL,

LED 18000LUMEN

146 VA LITHONIA,COLUMBIA,METALUX

IBH 18000LM SD080 120 0Z1035K 80CRI

120 V WHITE SURFACE

ST1 WALL STEP LIGHT LED 4 VA WAC OREQUILIVANT

WL LED 100 C BBR 120 V DK BRONZE SURFACE

ST4 4' LINEAR LED STRIP LIGHT. FROSTED DROP LENS. LED 5000LUMENS

41 VA LITHONIA,COLUMBIA,METALUX

ZLIN L48 5000LM FST 120 35K80CRI

120 V WHITE SURFACE

ST8 8' LINEAR LED STRIP LIGHT. FROSTED DROP LENS LED-10000LUMEN

82 VA LITHONIA,COLUMBIA,METALUX

TZL1D L96 10000LM FST 120 35K80CRI WH

120 V WHITE SURFACE

T2 2'X2' RECESSED FLAT PANEL LED LED-4000LM 35 VA LITHONIA,COLUMBIA,METALUX

EPANL 2234L 35K 120 V WHITE RECESSED 0' - 5"

UC 30" UNDERCABINET FIXTURE LED 13 VA JUNO OREQUILIVANT

UPS30 35K 120 V BLACK SURFACE

W1 36" X 4" TOILET ROOM ABOVE MIRROR FIXTURE LED 25 VA LITHONIA,COLUMBIA,METALUX

FMVCSL 36IN 35K 120 V BRUSHEDNICKEL

SURFACE

W2 WALL LIGHT - HIGH ABUSE WET LOCATION.POLYCARBONATE LENS

LED 30 VA FAILSAFE OREQUILIVANT

FW 1212 2500 35 UNV CP RAEOD1 LGBZ

120 V DK BRONZE SURFACE

X1 UNIVERSAL LED THERMOPLASTIC EXIT SIGNAGE,BATTERY BACK

DUAL MOUNTING OPTIONS, GREEN LETTERSCEILING MOUNTED SINGLE SIDED EXIT LIGHT, GREEN

LETTERS

LED 3 VA LITHONIA,COLUMBIA,METALUX

LQC-2-G-UNIVERSAL MOUNT 120 V WHITE UNIVERSAL MOUNT

X2 CEILING MOUNTED, DOUBLE SIDED EXIT LIGHT, GREENLETTERS

WITH SELF DIAGNOSTIC BATTERY

LED 5 VA LITHONIALIGHTING

LQC-2-G 120 V WHITE SURFACE

Mechanical Equipment Schedule

Key # Item HP FLA LoadEq Load

(VA) Voltage

Feeders Protection

NotesWire Ground ConduitBreake

r Disconnect Fuse

ACCU 1 CONDENSING UNIT 0 18 A 3744 VA 208V 1ph 2#10 #10G 3/4" 30 A 30 A 30 AB 1 BOILER 0 12 A 1440 VA 120V 1ph 2#12 #12G 3/4” 20 A SB 2 BOILER 0 12 A 1440 VA 120V 1ph 2#12 #12G 3/4” 20 A SCF 1 CEILING FAN 0 10 A 1200 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 ACP 1 CIRC PUMP 0.2 0 A 667 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 ACP 2 CIRC PUMP 0.2 0 A 667 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 ACPR 1 COMPRESSOR 7.5 0 A 8764 VA 208V 3ph 3#8 #10G 3/4” 45 A 60 A 40 ACPR 2 COMPRESSOR 15 0 A 16732 VA 208V 3ph 3#4 #8G 1-1/4” 90 A 100 A 70 ACUH 1 CABINET UNIT HEATER 0.1 0 A 506 VA 120V 1ph 2#12 #12G 3/4” 20 A SDAC 1 SPLIT SYSTEM AIR COND 0 13 A 2705 VA 208V 1ph 2#10 #10G 3/4" 30 A 30 A 30 ADR 1 DRYER 0 0 A 5000 VA 208V 1ph 2#8 #10G 3/4” 35 AEF 1 EXHAUST FAN 0.75 0 A 1587 VA 208V 1ph 2#12 #12G 3/4” 20 A SEF 2 EXHAUST FAN 0.75 0 A 1587 VA 208V 1ph 2#12 #12G 3/4” 20 A SEF 3 EXHAUST FAN 0.1 0 A 506 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 4 EXHAUST FAN 0.15 0 A 506 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 5 EXHAUST FAN 0.15 0 A 506 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 6 EXHAUST FAN 0.1 0 A 506 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 7 EXHAUST FAN 0 0 A 20 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 8 EXHAUST FAN 0 0 A 20 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 9 EXHAUST FAN 0 0 A 20 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 10 EXHAUST FAN 0 0 A 20 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 11 EXHAUST FAN 0 0 A 20 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 12 EXHAUST FAN 0 0 A 16 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 13 EXHAUST FAN 0 0 A 16 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 14 EXHAUST FAN 0 0 A 16 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 15 EXHAUST FAN 0 0 A 16 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEF 16 EXHAUST FAN 0.5 0 A 1127 VA 120V 1ph 2#12 #12G 3/4” 20 A 20 AEQ 1 BAY EQUIPMENT 0 0 A 7500 VA 208V 1ph 2#6 #10G 1” 50 AEUH 1 UNIT HEATER 0 0 A 3000 VA 208V 1ph 2#12 #12G 3/4” 20 A SEX 1 EXTRACTOR 0 0 A 7500 VA 208V 1ph 2#6 #10G 1” 50 AGUH 1 UNIT HEATER 0.5 0 A 1127 VA 120V 1ph 2#12 #12G 3/4” 20 A SGUH 2 UNIT HEATER 0.75 0 A 1587 VA 120V 1ph 2#12 #12G 3/4” 25 A SGUH 3 UNIT HEATER 0.3 0 A 832 VA 120V 1ph 2#12 #12G 3/4” 20 A SHD 1 KITCHEN HOOD 0 0 A 14 VA 120V 1ph 2#12 #12G 3/4” 20 A SHR 1 HOSE REEL 5 0 A 6055 VA 208V 3ph 3#10 #10G 3/4” 30 A 30 A 30 AP 1 PUMP 0 0 A 607 VA 208V 1ph 2#12 #12G 3/4” 20 A SP 2 PUMP 0 0 A 607 VA 208V 1ph 2#12 #12G 3/4” 20 A SPE 1 POWER EXHAUST 0 7 A 2522 VA 208V 3ph 3#12 #12G 3/4” 15 A 30 A 10 APE 2 POWER EXHAUST 0 11 A 3963 VA 208V 3ph 3#12 #12G 3/4” 15 A 30 A 15 APE 3 POWER EXHAUST 0 7 A 2522 VA 208V 3ph 3#12 #12G 3/4” 15 A 30 A 10 ARH 1 RADIENT HEATER 0 1 A 120 VA 120V 1ph 2#12 #12G 3/4” 20 A SRH 2 RADIENT HEATER 0 1 A 120 VA 120V 1ph 2#12 #12G 3/4” 20 A SRH 3 RADIENT HEATER 0 1 A 120 VA 120V 1ph 2#12 #12G 3/4” 20 A SRH 4 RADIENT HEATER 0 1 A 120 VA 120V 1ph 2#12 #12G 3/4” 20 A SRTU 1 ROOF TOP UNIT 0 45 A 16212 VA 208V 3ph 3#4 #10G 1-1/4” 60 A 60 A 60 ARTU 2 ROOF TOP UNIT 0 75 A 27020 VA 208V 3ph 3#2 #8G 1-1/4” 100 A 100 A 100 ARTU 3 ROOF TOP UNIT 0 45 A 16212 VA 208V 3ph 3#4 #10G 1-1/4” 60 A 60 A 60 AUH 1 UNIT HEATER 0 1 A 160 VA 120V 1ph 2#12 #12G 3/4” 20 A S

REVISIONS

Rev. # Description Date1 Addendum #2 10/18/2019

Charlene
colorado
Charlene
Typewritten Text
10/18/2019
Page 2: C:UsersCharleneDesktopCMOProjects 9190228 greeley fire

EXIST ASPHALT PAVEMENT

EXIST ASPHALT PAVEMENT

PROPOSED FIRE STATIONBUILDING

M

M

J

M

M

M

M

RTU1

RTU2

ACCU1

RTU3

TRANSFORMEREP2

EP2

EP2

ELA-56,58,60

ELA-55,57,59

ELB-16,18

MDP-4

LB-28

LB-28

LB-27

LB-27

LB-26

LB-26

LB-26

GENERATOR

R/WP/GFILB-24

WP/GFILA-26

PEDISTAL ACE #PAR C2H OR EQUILIVANT (TYP)

DUCT DETECTORFOR UNIT SHUTDOWNTYPES1

ES1

EW1 EW1 EW1 EW1 EW1

EW1

EW1EW1EW1EW1

D4 D4 D4

D4

D4E

1

1

1

1

1

1

11

PE1

ELA-48,50,52

PE2ELA-38,40,42

PE3LA-41,43,45

LB-25

LB-25

PROVIDE PHOTOCEL FOR CONTROL OF CIRCUIT LB-25

R

SEH ProjectChecked ByDrawn By

Project Status Issue Date

This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.

Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Shor

t Ellio

tt Hed

ricks

on, In

c.Al

l Righ

ts Re

serve

d

COPY

RIGH

T ©

2019

TechnologyBCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

DHM DESIGN900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group2525 South Wadsworth Blvd, Suite 200Lakewood, Colorado 80227303.988.4514

CMO Consuling Engineers, LLC11646 Sun Bear TrailGolden, Colorado 80403303.875.4037

10/17

/2019

5:48

:43 P

M

ELECTRICAL SITE PLAN

E010

GREE

LEY

FIRE

STA

TION

#2

2301

Res

ervo

ir Rd,

Gree

ley, C

O 80

634

18323.02

City

of Gr

eeley

100% CONSTRUCTIONDOCUMENTS

10/18/2019

POWER PLAN NOTES:1.

2.

3.

4.

5.

6.

7.

8.

MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING ELECTRICAL CONNECTION. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL MECHANICAL AND OTHER EQUIPMENT INCLUDED IN THIS PROJECT.

PROVIDE FUSES SIZED PER EQUIPMENT MANUFACTURER'S REQUIREMENTS.

DISCONNECT SWITCH LOCATIONS ARE SHOWN DIAGRAMMATICALLY OR LISTED IN SCHEDULE AND SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS TO SUIT EQUIPMENT AND SPACE. DISCONNECT SWITCHES SHALL BE WITHIN SIGHT OF THE EQUIPMENT THEY SERVE AND MOUNTED AT 6'-3", MAXIMUM, TO TOP OF CABINET. MAINTAIN NEC WORK SPACE REQUIREMENTS.

RECEPTACLES INDICATED WITH 'AC' ARE TO BE MOUNTED 6" ABOVE COUNTER.

COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS OF WALL AND FLOOR DEVICES WITH ARCHITECTURAL ELEVATIONS, AND ANY FURNITURE OR SPECIALTY EQUIPMENT SUPPLIER DRAWINGS PRIOR TO ROUGH-IN.

COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN.

CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V AND 277V SINGLE PHASE CIRCUIT. PROVIDE STRIPING FOR FULL LENGTH OF NEUTRAL CONDUCTOR INSULATION TO MATCH THE COLOR CODE OF THE ASSOCIATED PHASE CONDUCTOR. SEE SPECIFICATION FOR COLOR CODES.

GFCI RECEPTACLES ARE NOT GENERALLY SHOWN ON DRAWINGS. ALL RECEPTACLE OUTLETS LOCATED IN BAYS, GARAGE, TOILET ROOMS, SHOWER ROOMS, ROOFTOPS, OUTDOOR LOCATIONS, MECHANICAL ROOMS, WITHIN 6 FEET OF A SINK, OR OTHER WET LOCATIONS SHALL BE PROVIDED WITH GFCI PROTECTION PER NEC ARTICLE 210. ADDITIONAL GFCI PROTECTION TO BE PROVIDED AS INDICATED.

LIGHTING PLAN NOTES:1.

2.

3.

4.

5.

6.

REFER TO ARCHITECTURAL ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES.

COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V AND 277V SINGLE PHASE CIRCUIT. PROVIDE STRIPING FOR FULL LENGTH OF NEUTRAL CONDUCTOR INSULATION TO MATCH THE COLOR CODE OF THE ASSOCIATED PHASE CONDUCTOR. SEE SPECIFICATION FOR COLOR CODES.

FIELD COORDINATE EXACT LOCATION OF CEILING MOUNTED OCCUPANCY SENSORS PER MANUFACTURER'S INSTRUCTIONS. THE LOCATIONS OF THE OCCUPANCY SENSORS ON THE DRAWINGS ARE DIAGRAMMATIC.

'NL' AND EXIT LIGHTING FOR EGRESS AND EXIT SIGNS IS TO BE UN-SWITCHED.

OCCUPANCY SENSORS SHALL BE WATTSTOPPER DSW-301 FOR WALL AND DT-355 FOR CEILING (OR EQUILIVANT) WITH DUAL TECHNOLOGY SET FOR 30 MINUTES.

SCALE: 1" = 20'-0"SITE PLAN

WP/GFI

WP/GFI

WP/GFI

WP/GFI

REVISIONS

Rev. # Description Date1 Addendum #2 10/18/2019

Charlene
colorado
Charlene
Typewritten Text
10/18/2019
Page 3: C:UsersCharleneDesktopCMOProjects 9190228 greeley fire

EXIST ASPHALT

EXIST ASPHALT PAVEMENT

PROPOSED FIRE STATIONBUILDING

0.0 0.0 0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

22.5

0.4

0.3

0.5

0.5

0.4

0.4

0.8

0.7

0.6

0.6

0.5

0.5

0.5

0.4

1.0

0.9

0.8

0.8

0.7

0.7

0.6

0.6

0.5

0.5

0.5

1.3

1.2

1.1

1.0

0.9

0.9

0.8

0.8

0.7

0.7

0.6

0.6

0.5

1.7

1.6

1.5

1.4

1.3

1.2

1.1

1.0

1.0

0.9

0.9

0.8

0.8

0.7

0.7

0.6

0.6

1.9

1.9

1.8

1.7

1.6

1.5

1.4

1.3

1.2

1.2

1.1

1.0

1.0

0.9

0.9

0.8

0.8

0.8

0.7

0.7

2.0

2.1

2.0

2.0

1.9

1.8

1.7

1.6

1.5

1.4

1.4

1.3

1.2

1.2

1.1

1.1

1.0

0.9

0.9

0.8

0.8

0.7

2.0

2.1

2.1

2.1

2.1

2.1

2.1

2.0

2.0

1.9

1.8

1.7

1.6

1.6

1.5

1.4

1.3

1.2

1.2

1.1

1.0

1.0

0.9

0.8

0.8

0.7

2.3

2.2

2.3

2.3

2.2

2.2

2.2

2.2

2.2

2.2

2.1

2.1

2.0

2.0

1.9

1.7

1.6

1.5

1.4

1.3

1.2

1.2

1.1

1.1

1.0

0.9

0.8

0.7

0.6

2.6

2.6

2.6

2.6

2.6

2.5

2.4

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.2

2.0

1.9

1.7

1.6

1.5

1.5

1.4

1.4

1.3

1.2

1.1

1.0

0.9

0.7

0.6

0.5

0.5

2.6

2.8

2.9

2.9

2.9

2.9

2.8

2.7

2.7

2.6

2.5

2.4

2.4

2.5

2.4

2.3

2.2

2.1

2.0

1.9

1.8

1.7

1.6

1.6

1.6

1.5

1.4

1.3

1.1

0.9

0.8

0.7

0.6

0.5

0.5

2.6

2.8

2.8

2.9

3.0

3.1

3.1

3.1

3.0

2.9

2.8

2.6

2.5

2.5

2.5

2.4

2.4

2.3

2.2

2.1

2.0

1.9

1.9

1.9

1.9

1.8

1.7

1.6

1.4

1.2

1.0

0.9

0.8

0.7

0.6

0.5

0.4

2.8

3.0

3.2

3.4

3.4

3.3

3.1

3.1

3.2

3.1

3.1

2.9

2.7

2.6

2.6

2.5

2.4

2.4

2.3

2.3

2.2

2.1

2.1

2.1

2.1

2.1

2.1

1.9

1.7

1.5

1.3

1.1

1.0

0.9

0.8

0.7

0.6

2.7

2.9

3.1

3.5

3.8

4.2

4.1

3.8

3.5

3.4

3.2

3.1

3.2

3.1

3.1

2.7

2.5

2.5

2.5

2.5

2.4

2.4

2.3

2.3

2.3

2.3

2.3

2.3

2.2

2.0

1.8

1.6

1.4

1.2

1.1

1.0

0.9

0.7

2.8

3.0

3.4

4.0

4.6

5.2

5.1

4.5

4.3

4.0

3.4

3.2

3.2

3.2

3.1

2.7

2.6

2.5

2.5

2.5

2.5

2.5

2.4

2.4

2.4

2.4

2.4

2.4

2.3

2.2

2.1

1.9

1.7

1.5

1.4

1.2

1.1

0.9

2.8

3.1

3.5

4.2

5.0

5.7

5.6

5.8

5.1

4.2

3.8

3.4

3.2

3.1

2.8

2.7

2.6

2.6

2.6

2.6

2.6

2.6

2.5

2.5

2.6

2.6

2.5

2.5

2.4

2.3

2.2

2.1

2.0

1.9

1.7

1.5

1.3

1.2

2.6

2.8

3.1

3.5

4.0

5.0

5.8

5.6

5.8

5.2

4.5

3.8

3.4

3.3

3.0

2.7

2.6

2.7

2.7

2.7

2.7

2.6

2.6

2.6

2.6

2.8

3.0

2.8

2.6

2.6

2.5

2.3

2.2

2.2

2.1

2.0

1.8

1.6

1.5

2.8

2.9

2.9

3.3

3.9

4.3

4.5

5.2

5.4

4.9

4.3

3.8

3.5

3.4

3.0

2.8

2.8

2.8

2.7

2.8

2.8

2.7

2.7

2.6

2.6

3.0

3.1

3.1

3.0

3.0

2.8

2.6

2.4

2.2

2.1

2.1

2.0

1.9

1.8

2.7

2.9

2.9

3.1

3.3

3.5

3.9

4.2

4.4

4.1

3.8

3.5

3.4

3.3

3.0

3.0

3.0

3.0

2.9

2.9

2.9

3.0

2.9

2.7

2.7

2.9

3.2

3.2

3.1

3.1

3.0

2.9

2.7

2.5

2.3

2.2

2.1

2.1

2.0

2.3

2.4

2.7

3.0

3.1

3.2

3.2

3.3

3.5

3.7

3.7

3.6

3.5

3.3

3.1

2.9

3.0

3.1

3.1

3.0

2.9

3.0

3.0

3.0

2.9

2.9

3.1

3.2

3.2

3.2

3.2

3.2

3.1

3.0

2.8

2.7

2.4

2.2

2.1

2.1

2.2

2.3

2.5

2.7

2.9

3.0

3.2

3.3

3.3

3.3

3.3

3.3

3.2

3.2

2.8

2.7

2.9

3.0

3.0

2.9

3.0

3.0

3.0

2.9

3.0

3.2

3.3

3.4

3.6

3.7

3.6

3.4

3.1

3.0

3.0

2.9

2.7

2.4

2.2

2.0

2.2

2.3

2.3

2.4

2.6

2.8

2.9

3.0

3.2

3.2

3.3

3.4

3.3

3.2

2.7

2.7

2.7

2.8

2.8

2.8

2.8

2.8

2.9

2.9

3.0

3.3

3.4

3.5

3.9

4.2

4.3

4.1

3.6

3.3

3.1

3.0

2.9

2.7

2.4

2.2

2.0

2.2

2.2

2.3

2.3

2.4

2.4

2.6

2.8

2.9

3.0

3.1

3.0

3.1

3.2

2.8

2.7

2.7

2.7

2.7

2.7

2.8

2.8

2.7

2.7

3.0

3.3

3.4

3.8

4.4

4.9

5.4

4.8

4.2

4.1

3.5

3.0

2.8

2.9

2.7

2.5

1.8

2.0

2.1

2.2

2.3

2.3

2.4

2.4

2.5

2.6

2.7

2.7

2.6

2.9

2.9

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.9

3.1

3.3

3.6

3.8

4.5

5.3

5.8

4.7

5.5

4.6

3.8

3.3

2.8

2.7

2.6

2.4

1.5

1.7

1.8

1.9

2.1

2.2

2.3

2.4

2.4

2.5

2.5

2.5

2.5

2.5

2.6

2.5

2.6

2.6

2.7

2.7

2.7

2.7

2.7

2.9

3.2

3.2

3.2

3.4

3.8

4.3

5.3

5.7

5.9

5.5

4.8

3.9

3.3

3.0

2.7

2.4

2.0

1.2

1.3

1.4

1.5

1.6

1.8

1.9

2.0

2.2

2.3

2.4

2.4

2.4

2.4

2.4

2.4

2.4

2.5

2.5

2.6

2.6

2.6

2.6

2.7

3.0

3.2

3.3

3.3

3.2

3.4

4.0

4.3

4.3

5.4

5.1

4.5

3.8

3.2

2.9

2.6

2.2

1.9

1.1

1.2

1.3

1.3

1.4

1.5

1.6

1.7

1.9

2.0

2.1

2.1

2.2

2.3

2.3

2.3

2.3

2.3

2.4

2.4

2.5

2.6

2.6

2.7

2.7

2.8

2.9

3.2

3.2

3.2

3.4

3.4

3.9

4.2

4.1

3.8

3.4

3.1

2.9

2.6

2.2

2.0

1.0

1.1

1.1

1.2

1.3

1.4

1.5

1.5

1.6

1.7

1.6

1.7

1.9

2.0

2.1

2.1

2.1

2.1

2.2

2.3

2.4

2.5

2.6

2.6

2.6

2.6

2.7

3.0

3.1

3.1

3.1

3.1

3.2

3.4

3.5

3.4

3.2

2.9

2.8

2.4

2.2

2.1

0.9

1.0

1.0

1.1

1.1

1.2

1.3

1.3

1.4

1.4

1.5

1.2

1.4

1.5

1.7

1.8

1.8

1.8

1.9

1.9

2.1

2.2

2.3

2.4

2.5

2.6

2.6

2.5

2.6

2.8

2.9

3.0

3.1

3.1

3.0

3.0

2.9

2.8

2.7

2.4

2.1

2.1

2.1

0.9

1.0

1.0

1.1

1.1

1.2

1.2

1.2

1.2

1.2

0.9

0.9

1.1

1.2

1.4

1.5

1.5

1.6

1.6

1.7

1.8

1.9

2.1

2.2

2.4

2.4

2.4

2.4

2.4

2.4

2.5

2.7

2.8

2.9

2.9

2.9

2.9

2.8

2.6

2.2

1.9

1.9

2.0

1.0

1.1

1.1

1.1

1.1

1.1

1.2

1.1

1.1

0.7

0.6

0.7

0.8

0.9

1.1

1.2

1.2

1.3

1.4

1.4

1.5

1.6

1.8

1.9

2.0

2.1

2.2

2.3

2.3

2.3

2.3

2.3

2.5

2.6

2.7

2.7

2.7

2.7

2.6

2.1

1.9

1.8

1.7

1.1

1.1

1.1

1.1

1.1

1.2

1.2

1.2

1.2

1.1

0.5

0.5

0.6

0.6

0.7

0.8

0.9

1.0

1.1

1.1

1.2

1.3

1.4

1.5

1.6

1.7

1.8

1.9

2.0

2.1

2.2

2.2

2.2

2.2

2.2

2.3

2.3

2.3

2.5

2.4

2.0

1.8

1.7

1.5

1.3

1.3

1.3

1.2

1.2

1.3

1.6

2.4

3.0

2.1

1.9

2.0

2.1

2.1

2.1

2.1

2.2

2.1

2.1

2.1

1.8

1.7

1.6

1.5

1.5

1.5

1.4

1.4

1.4

1.9

4.3

8.5

10.4

9.3

1.3

1.6

1.8

1.9

2.0

2.1

2.2

2.1

2.0

1.9

1.7

1.6

1.5

1.4

1.7

1.7

1.6

1.5

1.7

4.1

10.5

21.8

22.1

1.1

1.2

1.5

1.6

1.8

2.0

2.1

2.0

1.9

1.8

1.6

1.5

1.4

1.3

1.9

1.9

1.9

1.7

1.6

2.4

6.6

19.0

1.0

1.1

1.3

1.6

1.8

1.9

1.8

1.7

1.6

1.5

1.4

1.3

1.2

2.1

2.1

2.1

1.9

1.8

2.6

6.9

17.1

0.8

0.8

1.0

1.4

1.5

1.6

1.6

1.5

1.5

1.3

1.2

1.2

1.1

2.1

2.2

2.1

1.9

1.9

2.7

6.7

15.6

0.6

0.7

1.1

1.1

1.3

1.4

1.4

1.3

1.2

1.2

1.1

1.0

0.9

2.0

2.2

2.3

2.3

2.1

2.1

3.4

8.0

18.2

0.5

0.7

1.2

1.1

1.1

1.2

1.2

1.1

1.0

1.0

0.9

0.8

0.8

2.5

2.6

2.7

2.7

2.6

2.6

3.6

8.0

16.6

0.4

1.8

1.8

1.6

1.3

1.2

1.0

0.9

0.9

0.8

0.8

0.7

0.7

2.8

2.9

3.0

2.9

2.9

2.9

3.9

8.0

16.5

0.3

2.9

2.5

2.3

1.7

1.2

0.9

0.8

0.7

0.7

0.6

0.6

0.6

2.8

3.1

3.1

3.3

3.2

3.3

3.0

4.2

9.1

17.7

3.8

3.5

2.9

2.9

2.1

1.4

0.8

0.7

0.6

0.6

0.5

0.5

0.5

3.0

3.4

3.6

3.9

3.7

3.7

3.3

3.9

6.7

13.0

5.0

4.2

2.9

2.8

2.0

1.2

0.7

0.6

0.5

0.5

0.4

0.4

0.4

3.2

3.8

4.4

4.7

4.5

4.1

3.7

3.6

4.7

5.8

4.3

2.8

2.4

5.8

5.6

4.7

3.3

3.0

2.1

1.2

0.7

0.5

0.4

0.4

0.3

0.3

0.3

3.0

3.4

4.2

5.2

5.5

5.3

4.6

4.2

4.3

4.5

4.6

4.3

3.7

2.8

5.4

5.7

5.2

4.1

3.8

2.6

1.5

0.8

0.5

0.4

0.3

0.3

0.3

0.3

2.9

3.3

4.0

5.5

5.9

5.7

4.6

4.5

4.9

5.4

5.3

5.3

4.9

3.7

5.1

5.9

5.9

5.0

4.4

2.9

1.7

0.8

0.5

0.3

0.3

0.2

0.2

0.2

2.9

3.3

4.0

5.5

5.9

5.7

4.7

4.6

5.2

5.6

5.6

6.4

6.4

4.9

5.4

5.9

5.5

4.5

4.2

2.8

1.7

0.8

0.5

0.3

0.2

0.2

0.2

0.2

2.9

3.0

3.4

4.2

5.2

5.5

5.5

4.8

4.7

5.3

5.7

5.9

7.3

7.5

6.2

6.2

5.5

4.0

3.5

2.3

1.4

0.7

0.5

0.3

0.2

0.2

0.1

0.1

2.8

2.9

3.2

3.8

4.4

4.8

4.7

4.6

4.8

5.6

6.2

6.6

7.8

7.7

6.3

6.4

5.6

4.2

3.8

2.5

1.5

0.8

0.5

0.3

0.2

0.1

0.1

0.1

2.8

2.8

3.0

3.5

3.7

4.0

4.0

4.5

5.1

6.3

7.2

7.3

7.9

7.5

6.0

6.6

6.2

5.0

4.6

3.1

1.8

0.8

0.5

0.3

0.2

0.1

0.1

0.1

2.3

2.6

2.8

2.8

3.2

3.2

3.5

3.6

4.2

5.0

6.5

7.3

7.5

8.2

7.6

5.9

6.6

6.3

5.3

4.9

3.3

1.9

0.9

0.5

0.3

0.2

0.1

0.1

0.1

2.2

2.5

2.8

2.7

2.8

3.0

3.2

3.4

3.8

4.6

5.9

6.5

6.9

8.1

8.0

6.4

6.6

5.9

4.5

4.1

2.7

1.6

0.8

0.5

0.3

0.1

0.1

0.1

0.1

2.2

2.6

2.6

2.5

2.6

2.7

3.0

3.1

3.5

4.3

5.6

6.5

6.8

8.4

8.5

6.6

6.6

5.9

4.4

3.8

2.6

1.5

0.8

0.5

0.3

0.1

0.1

0.1

0.1

1.9

2.0

2.2

2.3

2.1

2.1

2.4

2.6

2.8

3.2

4.2

5.9

6.6

7.2

8.7

8.6

6.2

6.6

6.2

4.9

4.4

3.0

1.8

0.8

0.5

0.3

0.1

0.1

0.1

0.1

1.7

1.8

1.8

1.9

1.9

2.0

2.3

2.5

2.7

3.1

4.4

6.1

7.1

7.4

8.5

8.0

5.8

6.5

6.4

5.4

5.0

3.3

1.9

0.9

0.4

0.3

0.1

0.1

0.1

0.1

1.6

1.6

1.7

1.7

1.8

1.9

2.2

2.4

2.6

3.0

3.9

5.3

6.2

6.9

8.4

8.3

6.3

6.6

6.0

4.6

4.2

2.8

1.6

0.8

0.4

0.2

0.1

0.1

0.1

1.4

1.4

1.5

1.5

1.6

1.6

1.8

2.0

2.2

2.4

2.7

3.4

4.6

5.5

6.3

8.0

8.1

6.6

6.6

5.8

4.3

3.7

2.4

1.4

0.7

0.4

0.2

0.1

0.1

0.1

1.2

1.3

1.4

1.4

1.4

1.4

1.6

1.8

1.9

2.1

2.6

3.4

4.7

5.6

6.3

7.6

7.4

6.2

6.5

5.9

4.5

4.1

2.7

1.6

0.7

0.4

0.2

0.1

0.1

0.1

1.1

1.2

1.3

1.3

1.3

1.3

1.4

1.5

1.7

1.9

2.5

3.6

5.1

6.2

6.7

7.5

6.9

5.6

6.3

6.2

5.2

4.8

3.1

1.8

0.8

0.4

0.2

0.1

0.1

0.8

1.0

1.0

1.1

1.1

1.1

1.2

1.3

1.3

1.5

1.7

2.2

3.2

4.7

5.5

6.0

7.1

6.8

5.9

6.3

5.8

4.5

4.1

2.7

1.5

0.7

0.3

0.2

0.1

0.1

0.7

0.8

0.9

1.0

1.0

1.0

1.0

1.1

1.1

1.3

1.4

1.8

2.5

3.7

4.4

5.0

6.7

6.8

6.0

5.9

5.0

3.6

3.3

2.1

1.2

0.6

0.3

0.2

0.1

0.1

0.6

0.7

0.8

0.8

0.8

0.9

0.9

0.9

0.9

1.1

1.2

1.6

2.2

3.2

3.7

4.2

5.9

6.1

5.1

5.0

4.2

2.9

2.8

1.8

1.0

0.5

0.3

0.2

0.1

0.1

0.5

0.6

0.6

0.7

0.7

0.7

0.7

0.8

0.8

0.8

0.9

1.0

1.4

2.2

3.1

3.5

3.7

4.7

2.7

3.5

3.7

3.5

2.8

2.7

1.9

1.1

0.5

0.3

0.1

0.1

0.4

0.5

0.5

0.6

0.6

0.6

0.6

0.6

0.7

0.7

0.8

0.9

1.2

1.7

2.4

2.9

3.3

3.6

0.7

2.2

2.6

2.7

2.3

2.0

1.3

0.8

0.4

0.2

0.1

0.1

0.5

0.5

0.5

0.5

0.5

0.6

0.6

0.6

0.7

0.7

1.0

1.3

1.7

2.0

2.2

1.4

0.5

1.1

1.3

1.5

1.4

1.2

0.8

0.6

0.3

0.2

0.1

0.1

0.5

0.5

0.5

0.5

0.5

0.6

0.8

0.9

1.0

1.2

1.3

0.5

0.5

0.5

0.6

0.7

0.7

0.5

0.4

0.4

0.2

0.2

0.1

0.5

0.6

0.7

0.8

0.9

0.7

0.4

0.4

0.1

0.1

0.2

0.3

0.4

0.4

0.3

0.3

0.3

0.2

0.1

0.1

0.7

0.7

1.1

1.9

2.7

4.1

5.2

4.8

3.4

2.2

1.1

0.5

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.2

0.2

0.1

0.1

0.1

M

R

SEH ProjectChecked ByDrawn By

Project Status Issue Date

This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.

Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Shor

t Ellio

tt Hed

ricks

on, In

c.Al

l Righ

ts Re

serve

d

COPY

RIGH

T ©

2019

TechnologyBCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

DHM DESIGN900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group2525 South Wadsworth Blvd, Suite 200Lakewood, Colorado 80227303.988.4514

CMO Consuling Engineers, LLC11646 Sun Bear TrailGolden, Colorado 80403303.875.4037

10/17

/2019

5:48

:46 P

M

SITE PHOTOMETRICS

E011

GREE

LEY

FIRE

STA

TION

#2

2301

Res

ervo

ir Rd,

Gree

ley, C

O 80

634

18323.02

City

of Gr

eeley

100% CONSTRUCTIONDOCUMENTS

7/12/2017

SCALE: 1" = 10'-0"SITE PHOTOMETRICS

PROP

ERTY

BOU

NDAR

Y

REVISIONS

Rev. # Description Date1 Addendum #2 10/18/2019

1

Charlene
colorado
Charlene
Typewritten Text
10/18/2019
Page 4: C:UsersCharleneDesktopCMOProjects 9190228 greeley fire

R

SEH ProjectChecked ByDrawn By

Project Status Issue Date

This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.

Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Shor

t Ellio

tt Hed

ricks

on, In

c.Al

l Righ

ts Re

serve

d

COPY

RIGH

T ©

2019

TechnologyBCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

DHM DESIGN900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group2525 South Wadsworth Blvd, Suite 200Lakewood, Colorado 80227303.988.4514

CMO Consuling Engineers, LLC11646 Sun Bear TrailGolden, Colorado 80403303.875.4037

10/17

/2019

5:48

:48 P

M

EXTERIOR LIGHT CUT SHEETS

E012

GREE

LEY

FIRE

STA

TION

#2

2301

Res

ervo

ir Rd,

Gree

ley, C

O 80

634

18323.02

City

of Gr

eeley

100% CONSTRUCTIONDOCUMENTS

7/12/2017

REVISIONS

Rev. # Description Date1 Addendum #2 10/18/2019

1

Charlene
colorado
Charlene
Typewritten Text
10/18/2019
Page 5: C:UsersCharleneDesktopCMOProjects 9190228 greeley fire

OS

OS

OS

OSOS

OSOS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

M

1

D

C

B

A

2 3 4 5

HOSE TOWER145

WATCH ROOM129

COMP140

SCBA138

SUPPLY144

LOBBY101

UNISEX103

BUNK111

BUNK112

MECH.124

EMS143

BUNK113

BUNK110

BUNK108

BUNK109

DECON142

APPARATUS BAY(LADDER)

134

WORKSHOP137

PPE STORAGE141

LAUNDRY116

VEST.132

ELEC136

APPARATUS BAY(ENGINE)

135APPARATUS BAY(SQUAD VEHICLE)

133

LT.105PROGRAMS

104

BUNK107

BUNK106

BATHROOM117

BATHROOM118

BATHROOM119

ADA BATHROOM120

DAYROOM125

IT128

RR130

CORRIDOR114

KITCHEN115

EXAM102

CATV122

WATER ENTRY139

STO.121

RADIO131

S4S

D3E

D3E

A3

A3

ST8

ST8

ST8 ST8

ST8

ST8

ST4 ST4

ST8

ST4

A3

A3

D3E

W1

W1

W1

W1

W1

W1

D3

D3

D3E

D3

D3

D3D3E

DS

S4S S4S S4S

ST4 ST4

ST4ST4

EW1 EW1 EW1

ST1

EW1

EW1 EW1 EW1 EW1

D3 D3

DS DS

ST8

DS

T2

T2

D3 D3 D3 D3E

D3E D3 D3 D3

D3 D3

D3 D3

D3 D3

D3D3

D3 D3

D3D3

D3

D3 D3

D3

D3 D3

D3D3

D3 D3

D3

D3 D3

D3D3

D3 D3

D3D3

D3E D3

D3

D3E

D3

DS DS

DS DS

DS DS

DS

ST4T2

T2

S4S

S4S S4S S4S S4S

S4S S4S S4S

S4S S4S S4S S4S

D3 D3 D3

D3D3

D3 D3E

D3 D3 D3

D3D3

D3E

D3E D3 D3 D3

D3 D3

D3 D3 D3 D3

R1

R1

UC UC UC UC

UC UC

EW1

ST1 W2

W2

FAN D

D

D

D

D

DD

D

DD

D

D

X1

CF

CFCF

CF

CF

CF

CF

DFAN

FAN

FAN

D

FAN

FAN

FAN

D

FAN

T

X1

X1

X2

D

D3E

X1

X1

R1 R1

CF

CF

ST4

ST4ST4

LB

ELB

ELA

LA

MOUNT USING SOLID CONDUIT SUPPORTS AT 18' AFF (TYP)

X1

X1 X1

X1

D

ELA-6

ELA-6

ELA-6

ELA-2

ELA-6

ELA-6

ELA-6

ELA-6

ELA-6

ELA-6

ELA-6

ELA-6 ELA-6

ELA-6

ELA-6

ELA-6ELA-6

ELA-6

ELA-6

ELA-2

ELA-6ELA-6ELA-6

ELB-4

ELA-4 ELA-4 ELA-2

ELA-4 ELA-4 ELA-2 ELA-2

ELA-4 ELA-4 ELA-2 ELA-2

ELA-4 ELA-4 ELA-2

ELA-6ELA-6ELA-6ELA-6

ELB-4

ELB-4ELB-4

ELB-4ELB-4

ELB-4

ELB-4ELB-2

ELB-2

ELB-2

ELB-2ELB-2

ELB-2

ELB-2

ELB-2

ELB-2

ELB-2

ELB-2

ELB-2 ELB-2

ELB-2

ELB-4

ELB-4

ELB-4

ELB-4

ELB-4

ELB-4

ELB-4

NL

BELOW STAIRS AT 5' AFF

5' AFF

W2

11' AFF

11' AFF11' AFF11' AFF11' AFF

11' AFF 11' AFF 11' AFF 12' AFF11' AFF

5' AFF

ELA-6

ELA-6

1'6" ABOVE STAIRS TYP

EW1ELA-6

ST1 ST1ELA-6 ELA-6D4

D4E

D4 D4 D4

ELB-4PROVIDE TIME SWITCH INTERMATIC ST700W OR EQUILIVANT. SET ON FOR7AM AND 'OFF' FOR 8PM.

NL

NL

NL

NL

NL

ST1

ST1

ST1

ST1

PROVIDE CONTACT FOR AUTOMATIC'ON' CONTROL OF TYPE D3 BUNK LIGHTS. (TYP OF 10 BUNK ROOMS) AND TYPE ST1 STEP LIGHTS. COORDINATEWITH SPECIALTY EQUIPMENT CONTRACTOR.

TYP D3 (DIM)TYP R1 (DIM)

FAN

1

1

1 1

1

1ST4

1

ELB-2

ELB-2

ELB-2

ELB-2

1

1

1

1

JANITOR202

BATHROOM201

FITNESS ROOM203

HOSE TOWER204

W1

DS

ST1 ST1

W2

W2

W2

ST8

ST8

ST8

ST8

ST8

ST4

80" AFF TO BOTTOMTYP

ELA-6

ELA-6

ELA-6

ELA-6ELA-6

ST1ELA-6

ST1

ST1

ST1ELA-6

ELA-6 ELA-6

ST1ELA-6

DS

1

D

4 5

W2 EW3

ST1

ELA-6

ELA-6

W2

ELA-6

ELA-6

LA-35,37,39

HR1

ST1ELA-6

R

SEH ProjectChecked ByDrawn By

Project Status Issue Date

This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.

Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Shor

t Ellio

tt Hed

ricks

on, In

c.Al

l Righ

ts Re

serve

d

COPY

RIGH

T ©

2019

TechnologyBCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

DHM DESIGN900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group2525 South Wadsworth Blvd, Suite 200Lakewood, Colorado 80227303.988.4514

CMO Consuling Engineers, LLC11646 Sun Bear TrailGolden, Colorado 80403303.875.4037

10/17

/2019

5:48

:55 P

M

LIGHTING PLAN

E111

GREE

LEY

FIRE

STA

TION

#2

2301

Res

ervo

ir Rd,

Gree

ley, C

O 80

634

18323.02

City

of Gr

eeley

100% CONSTRUCTIONDOCUMENTS

8/28/2019

LIGHTING PLAN NOTES:1.

2.

3.

4.

5.

6.

REFER TO ARCHITECTURAL ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES.

COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V AND 277V SINGLE PHASE CIRCUIT. PROVIDE STRIPING FOR FULL LENGTH OF NEUTRAL CONDUCTOR INSULATION TO MATCH THE COLOR CODE OF THE ASSOCIATED PHASE CONDUCTOR. SEE SPECIFICATION FOR COLOR CODES.

FIELD COORDINATE EXACT LOCATION OF CEILING MOUNTED OCCUPANCY SENSORS PER MANUFACTURER'S INSTRUCTIONS. THE LOCATIONS OF THE OCCUPANCY SENSORS ON THE DRAWINGS ARE DIAGRAMMATIC.

'NL' AND EXIT LIGHTING FOR EGRESS AND EXIT SIGNS IS TO BE UN-SWITCHED.

OCCUPANCY SENSORS SHALL BE WATTSTOPPER DSW-301 FOR WALL AND DT-355 FOR CEILING (OR EQUILIVANT) WITH DUAL TECHNOLOGY SET FOR 30 MINUTES.

SCALE: 1/8" = 1'-0"LEVEL 1 LIGHTING PLAN

SCALE: 1/8" = 1'-0"MEZZANINE

SCALE:

PROJECT NORTH

1/8" = 1'-0"HOSE TOWER PLATFORM

REVISIONS

Rev. # Description Date1 Addendum #2 10/18/2019

Charlene
colorado
Charlene
Typewritten Text
10/18/2019
Page 6: C:UsersCharleneDesktopCMOProjects 9190228 greeley fire

J J J

J J J

CLGCLG CLG

CLG CLG CLG

J

M

J

M

M

M

M

M

M

M

J

M

J

J

M

M

J

M

J

J

JJ J

M

M

J

M

M

J

J

J

J

J

JFACPGENN

J

JJ

P

P P

P

P

P

P

P

P

P

P

CLG CLG

CLG CLGJJ

J J

J

M

J

M

M

M

M

J

J

J J

M

M

JFACPGENN

J

1

D

C

B

A

2 3 4 5

BUNK111

BUNK112

BUNK113

CORRIDOR114

BUNK110

BUNK109

BUNK108

BUNK107

BUNK106

EXAM102

UNISEX103

LOBBY101

PROGRAMS104

LT.105

VEST.132

RR130

KITCHEN115

LAUNDRY116

BATHROOM117

BATHROOM118

BATHROOM119

ADA BATHROOM120

STO.121 CATV

122

IT128MECH.

124

DAYROOM125

WATCH ROOM129

APPARATUS BAY(SQUAD VEHICLE)

133

APPARATUS BAY(LADDER)

134

APPARATUS BAY(ENGINE)

135

ELEC136

WORKSHOP137

WATER ENTRY139

SCBA138

COMP140

PPE STORAGE141

DECON142

HOSE TOWER145

EMS143

SUPPLY144

RADIO131

CUH1

EF12

CONTROL CIRCUITABOVE CEILING

EF11

EF10

EF9

EF8

EF14

EF13

EF3

EF2

CF1

GUH1

EF1

EF6

EF5

UH1

EF4

CONTROLS CKTAT CEILING

MDP

ATS ELA

LA

GENERATOR

LB

ELB

+84"

+84"

+84"+84"

+84"

+84"

+84"

+84"

+84"+84"

GFI

GFI

GFI

GFI

GFI

GFI

GFIGFI

GFI GFI

GFIGFIGFI

GFI

GFI

GFI

GFI

WP/GFI

WP/GFI

+84"

HOSE DRYER

WP/GFI WP/GFI WP/GFI

WP/GFI

+84"

+84"

E2

E2 E2

E2

E2

E2

E2

E2 E2

E2

E2

E2

E1TYP

E3 E3 E3

E3 E3 E3

NO ELECTRICAL CONDUIT, WIRING OR DEVICES SHALL BE INSTALLED BELOW 18" AFF IN VEHICLE BAY AREA.

ALL RECEPTACLES IN BAY SHALL HAVE GFI TRIP PROTECTION OR GFI BREAKER

DEVICES MAY BE SURFACE MOUNTED IN BAY AREAS.

ELA-1,3ELA-5,7ELA-9,11

LA-1

LA-5

LA-1LA-5

LA-7,9LA-3 ELA-39

LA-3

LA-3

LA-3

LA-3

ELA-10

ELA-10ELA-10

ELA-10 ELA-10 ELA-10

ELA-27

ELA-25

ELA-29

ELA-20

ELA-18

ELA-12,14

ELB-24,26

ELA-31 ELA-33 ELA-35

ELA-13,15 ELA-17,19 ELA-21,23ELA-22

ELA-22

ELA-22

ELA-22

ELA-22

LA-11

LA-11

ELA-39

ELA-39

LA-8,10,12

ELA-26

LA-2,4,6

LA-13 LA-15

ELA-24

LA-19,21LA-17

ELA-24

ELA-24

ELA-24

LA-23,25

LA-27,29

LB-1

LB-3

LB-5

LB-7

LB-9

LB-11 LB-13

LB-15

ELB-3

ELB-3

ELB-3 LB-16

LB-16

ELB-1

ELB-5

LB-10

LB-10

LB-8 LB-2LB-4,6

LB-12LB-12

LB-12LB-12

LB-14

LB-14

LB-14LB-14

LB-16LB-16

LB-19

ELB-19

ELB-21

ELB-23

ELB-25

ELB-7

ELB-9

ELB-13

ELB-13

ELB-7

ELB-13

ELB-13

ELB-11

ELB-13

LB-10

LB-10

LB-10

LB-20LB-20

LB-20

LB-20

LB-20

LB-20

LB-20

ELA-28

ELB-17

CARD READERCARD READER

CARD READER

CARD READER

CARD READER

ELB-33,35

ELB-20

ELB-22

ELB-28

ELB-30ELB-32

LB-21,23

LB-22

LB-22

LB-22

LB-31

ELB-34

ELB-34

ELA-30

ELA-30ELA-30LB-18

LB-18

ELB-27

LB-17

ELB-27

ELB-29

LB-22

LA-31,33

ELB-38

ELB-38

ELB-38

ELB-40

ELB-40

ELB-40

PANIC HARDWARE

LA-34,36

ELB-36

ELB-37

DAC1

GUH2

GUH3

GFI

GFI

LB-29

LB-30

DR1

SEEENLARGEDPLAN

CPR1

CPR2

HD1

ELB-16,18

ELA-37 ELA-37

ELA-37 ELA-37

RH4

TELECOM GROUND BAR.SEE ONE LINE AND DETAIL

LB-22GFI TO FEED THROUGHTO WATER COOLER

RH3

RH1

RH2

GFIGFI

GFI

GFI

ELA-16

LA-13

LA-13

LA-13

LA-13LA-13 LA-15

LA-15

LA-15

LA-15

LA-15

LA-15LA-15

MOUNT RECEPTACLESSO EACH LOCKER HAS ACCESS TO POWER.

ELA-46

ELA-44

GENERATOR EPO

CT

EX1

DR1

LA-28,30

LB-1LB-1

LB-1

ELB-44 LB-1

LB-1

LB-15

LB-15LB-15

ELB-42

LB-15LB-15

ELB-42LB-13LB-13

LB-13 LB-13

LB-13

LB-11LB-11

LB-11

ELB-42 LB-11LB-11

LB-9LB-9

LB-9

ELB-42 LB-9LB-9

LB-7 LB-7

LB-7

LB-7

ELB-44

LB-5

LB-5

LB-3

LB-5

LB-5ELB-44

LB-10

LB-3LB-3

LB-3

ELB-44

EUH1

LA-38,40

EQ1

EQ1

EQ1

EQ1

MOUNT RECEPTACLES ATTOP OF RACK

HD1

ELB-31

ELB-15

D

C

B

A

4 5

EF7

JANITOR202 BATHROOM

201

FITNESS ROOM203

HOSE TOWER204

LA-14

LA-14LA-16

LA-16

LA-14

LA-18

LA-24LA-14

LA-20

LA-22

LA-26

LA-26

LA-26

LA-26

LA-26

+84" AFF

+84" AFF

LA-14

LA-14+84" AFF

+84" AFF

EF15

LA-32

EF16

LA-14

GFI - FEED THROUGHTO EWC

C

2

ELB-10

ELB-8CP2

B2

P1

P2

B1

CP1

ELB-10

ELB-6

ELB-12,14

ELB-12,14

ELB-15ELB-15

ELB

LB

LB-20

ELB-46

LB-20

R

SEH ProjectChecked ByDrawn By

Project Status Issue Date

This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.

Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Shor

t Ellio

tt Hed

ricks

on, In

c.Al

l Righ

ts Re

serve

d

COPY

RIGH

T ©

2019

TechnologyBCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

DHM DESIGN900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group2525 South Wadsworth Blvd, Suite 200Lakewood, Colorado 80227303.988.4514

CMO Consuling Engineers, LLC11646 Sun Bear TrailGolden, Colorado 80403303.875.4037

10/17

/2019

5:49

:05 P

M

POWER PLAN

E211

GREE

LEY

FIRE

STA

TION

#2

2301

Res

ervo

ir Rd,

Gree

ley, C

O 80

634

18323.02

City

of Gr

eeley

100% CONSTRUCTIONDOCUMENTS

8/28/2019

POWER PLAN NOTES:1.

2.

3.

4.

5.

6.

7.

8.

MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING ELECTRICAL CONNECTION. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL MECHANICAL AND OTHER EQUIPMENT INCLUDED IN THIS PROJECT.

PROVIDE FUSES SIZED PER EQUIPMENT MANUFACTURER'S REQUIREMENTS.

DISCONNECT SWITCH LOCATIONS ARE SHOWN DIAGRAMMATICALLY OR LISTED IN SCHEDULE AND SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS TO SUIT EQUIPMENT AND SPACE. DISCONNECT SWITCHES SHALL BE WITHIN SIGHT OF THE EQUIPMENT THEY SERVE AND MOUNTED AT 6'-3", MAXIMUM, TO TOP OF CABINET. MAINTAIN NEC WORK SPACE REQUIREMENTS.

RECEPTACLES INDICATED WITH 'AC' ARE TO BE MOUNTED 6" ABOVE COUNTER.

COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS OF WALL AND FLOOR DEVICES WITH ARCHITECTURAL ELEVATIONS, AND ANY FURNITURE OR SPECIALTY EQUIPMENT SUPPLIER DRAWINGS PRIOR TO ROUGH-IN.

COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN.

CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V AND 277V SINGLE PHASE CIRCUIT. PROVIDE STRIPING FOR FULL LENGTH OF NEUTRAL CONDUCTOR INSULATION TO MATCH THE COLOR CODE OF THE ASSOCIATED PHASE CONDUCTOR. SEE SPECIFICATION FOR COLOR CODES.

GFCI RECEPTACLES ARE NOT GENERALLY SHOWN ON DRAWINGS. ALL RECEPTACLE OUTLETS LOCATED IN BAYS, GARAGE, TOILET ROOMS, SHOWER ROOMS, ROOFTOPS, OUTDOOR LOCATIONS, MECHANICAL ROOMS, WITHIN 6 FEET OF A SINK, OR OTHER WET LOCATIONS SHALL BE PROVIDED WITH GFCI PROTECTION PER NEC ARTICLE 210. ADDITIONAL GFCI PROTECTION TO BE PROVIDED AS INDICATED.

SCALE: 1/8" = 1'-0"LEVEL 1 POWER PLAN

SCALE: 1/8" = 1'-0"LEVEL 2 POWER PLAN

FIRE ALARM PLAN NOTES:1.

2.

LOCATE SMOKE DETECTORS PER NFPA 72 AND MANUFACTURERS REQUIREMENTS. THE LOCATIONS OF SMOKE DETECTORS ON THE DRAWINGS ARE DIAGRAMMATIC ONLY. DETECTORS SHALL NOT BE PLACED WITHIN 3'-0" OF ANY CEILING MOUNTED HVAC SUPPLY AIR DEVICE.

PROVIDE GRAPHIC MAPS. SUBMIT TO ENGINEER AND BUILDING/FIRE DEPARTMENT(S) FOR REVIEW PRIOR TO INSTALLATION. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

KEYNOTESE1 POWER TO HOSE REEL. PROVIDE HOSE REEL REELCRAFT 120V HEAVY DUTY.E2 ALL DUPLEX RECEPTACLE OUTLETS NOT AT 84" AFF TO HAVE (2) ADDITIONAL USB POWER OUTLETS.E3 NEW 55" CEILING MOUNTED MONITOR. PROVIDE RECEPTACLE FOR POWER AND JBOX FOR DATA OUTLET

AT 96" AFF. SUPPORT FROM CEILING.

SCALE:

PROJECT NORTH

1/4" = 1'-0"ENLARGED MECHANICAL ROOM

REVISIONS

Rev. # Description Date1 Addendum #1 9/19/20192 Addendum #2 10/18/2019

Charlene
colorado
Charlene
Typewritten Text
10/18/2019
Page 7: C:UsersCharleneDesktopCMOProjects 9190228 greeley fire

SHORT-CIRCUIT CURRENT CALCULATIONS 10/17/2019

PROJECT NAME: GREELEY FIRE STATION #2 SERVICE VOLTAGE: 120Y/208V

ELECTRIC UTILITY: AVAILABLE FAULT CURRENT (A): 26000

EQUIPMENT DESCRIPTION FEEDERLENGTH VOLTAGE SIZE CU / AL

SINGLECONDUCTOR OR

CABLE

CONDUIT(STEEL OR

NM)# PARALLEL

RUNS

ISC ISC

SUPPLY m f FAULT

SWITCHBOARD MDP 40 208 3/0 CU S NM 2 26000 0.190438492 0.840026601 21841 PANEL LA 7 208 3/0 CU S S 1 21841 0.099117122 0.909821147 19871 PANEL LB 115 208 3/0 CU S S 1 21841 1.502159182 0.399654829 8729 RTU-3 75 208 4 CU S NM 1 21841 3.583797144 0.218159742 4765

TRANSFER SWITCH 5 208 3/0 CU S S 2 21841 0.035398972 0.965811274 21094 PANEL ELA 5 208 3/0 CU S S 2 21094 0.019793554 0.980590626 20685 RTU-1 140 208 3 CU S S 1 20685 5.050990695 0.165262194 3418 RTU-2 150 208 1/0 CU S S 1 20685 2.894769457 0.256754607 5311

PANEL ELB 115 208 3/0 CU S NM 1 20685 1.422643109 0.412772313 8538

NOTES:1. FEEDER LENGTHS INDICATED THIS SCHEDULE ARE ESTIMATED FOR PURPOSES OF SHORT‐CIRCUIT ANALYSIS ONLY, NOT FOR CONTRACTOR TAKE‐OFFS.

PANELELA

?

400A3P

PANELELB

PANELLB

PANELLA

200A3P 200A3P 200A3P600A

3P

MECH60A3P

TVSS

UTILITY TRANSFORMER

ISC=26000 AIC

GENERATOR100kw

2[4#3/0+#1G IN 3"C]

4#3/

0+#6

G IN

2-1

/2"C

2[4#3/0+#1G IN 3"C]

400A 3 POLE AUTOMATIC TRANSFER SWITCH

2[4#350+#1G IN 3"C]

NO SCALE

ELECTRICAL ONE LINE DIAGRAM

TVSS

TVSS

SPACE

NEC 702 OPTIONAL STANDBY GENERATOR

#2/0 BOND AND GROUND CONDUCTOR TO EUFER GROUND, WATER MAIN, AND BUILDING STEEL; AND A #6 TO DRIVEN GROUND ROD.

4#3/

0+#6

G IN

2-1

/2"C

4#3/

0+#6

G IN

2-1

/2"C

'MDP' 600A 120/208V 50K AIC

RTU-3

RTU-1RTU-2

#1 CONDUCTOR TO IT ROOM GROUND BAR.

NG

SEE

MEC

H SC

HEDU

LE

M

2[4#3/0+#1G IN 3"C]

CT CAB

R

SEH ProjectChecked ByDrawn By

Project Status Issue Date

This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.

Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Shor

t Ellio

tt Hed

ricks

on, In

c.Al

l Righ

ts Re

serve

d

COPY

RIGH

T ©

2019

TechnologyBCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

DHM DESIGN900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group2525 South Wadsworth Blvd, Suite 200Lakewood, Colorado 80227303.988.4514

CMO Consuling Engineers, LLC11646 Sun Bear TrailGolden, Colorado 80403303.875.4037

10/17

/2019

5:49

:06 P

M

ONE LINE DIAGRAM

E401

GREE

LEY

FIRE

STA

TION

#2

2301

Res

ervo

ir Rd,

Gree

ley, C

O 80

634

18323.02

City

of Gr

eeley

100% CONSTRUCTIONDOCUMENTS

8/28/2019

** = Shunt Trip* = GFIBreaker Accessories

General Notes:O Other 0 VA 0% 0 VAE Existing 0 VA 0% 0 VA Total Demand Current: 239 AK Kitchen 0 VA 0% 0 VA Total Demand Load: 86097 VAG General 34872 VA 100% 34872 VAC Continuous 0 VA 0% 0 VA Total Connected Current: 236 AM Motor 35714 VA 112% 39897 VA Total Connected Load: 85190 VAR Receptacle 16489 VA 80% 13244 VAL Lighting 0 VA 0% 0 VA Power Factor: 1

Load Type Connected... Demand Factor Demand Load Panel TotalsPhase Balance: 22 % A-B 38 % B-C 14 % C-A

Total Amps: 232 A 282 A 204 ATotal Load: 27387 VA 33426 VA 24464 VA

59 6057 5855 5653 5451 5249 5047 4845 841 VA 4643 841 VA 4441

PE-3 G 15 A 3841 VA 42

39 2018... 1500... 4037 2018... 1500...

2 20 A M EUH-138

35HOSE LIFT M 20 A 3

2018... 3750... 3633 3750... 3750...

2 50 A G REC BAY34

31REC BAY G 50 A 2

3750... 1127... 1 20 A M EF 3229 3750... 2500... 3027

REC NORTH EXT G 50 A 23750... 2500...

2 35 A R DRYER28

25 500 VA 1900... 1 20 A R REC FITNESS 2623

REC HOSE DRYER G 20 A 2500 VA 1000... 1 20 A R REC BIKE 24

21 3750... 1000... 1 20 A R REC BIKE 2219 EXTRACTOR

DECONTAM G 50 A 23750... 1000... 1 20 A R REC TREADMILL 20

17 WASHER DECONTAM G 20 A 1 1000... 1000... 1 20 A R REC TREADMILL 1815 REC PPE STORAGE R 20 A 1 1440... 360 VA 1 20 A R EWC FITNESS 1613 REC PPE STORAGE R 20 A 1 1080... 906 VA 1 20 A R; M REC FITNESS 1411 REC COMP R 20 A 1 360 VA 5577... 129 1000... 5577... 107

REC DRILLPRESS G 20 A 21000... 5577...

3 90 A M COMPRESSOR8

5 REC WORKSHOP R 20 A 1 360 VA 2921... 63 REC EAST R 20 A 1 900 VA 2921... 41 REC WORKSHOP R 20 A 1 360 VA 2921...

3 45 A M COMPRESSOR2

Note Circ... Load Type Trip Po... A B C Po... Trip Type Load Circ... Note

Circuit Notes:Enclosure: Type 1 Feed:Mounting: Surface Wire: 4 Bus Rating: 225 A

Supply From: MDP Phase: 3 Mains Type: MLOLocation: ELEC 136 Voltage: 120/208 Wye A.I.C. Rating: 22K

New Panel LA

** = Shunt Trip* = GFIBreaker Accessories

General Notes:O Other 0 VA 0% 0 VAE Existing 0 VA 0% 0 VA Total Demand Current: 271 AK Kitchen 0 VA 0% 0 VA Total Demand Load: 97517 VAG General 56399 VA 100% 56399 VAC Continuous 0 VA 0% 0 VA Total Connected Current: 277 AM Motor 17435 VA 104% 18111 VA Total Connected Load: 99713 VAR Receptacle 19167 VA 76% 14584 VAL Lighting 6963 VA 125% 8704 VA Power Factor: 1

Load Type Connected... Demand Factor Demand Load Panel TotalsPhase Balance: 0 % A-B 8 % B-C 8 % C-A

Total Amps: 286 A 286 A 264 ATotal Load: 33980 VA 34021 VA 31722 VA

59 9007... 5404... 6057 9007... 5404... 5855

RTU-2 G 150 A 39007... 5404...

3 90 A G RTU-156

53 Spare -- 20 A 1 0 VA 0 VA 1 20 A -- Spare 5451 Spare -- 20 A 1 0 VA 841 VA 5249 Spare -- 20 A 1 0 VA 841 VA 5047 Spare -- 20 A 1 0 VA 841 VA

3 20 A G PE-148

45 Spare -- 20 A 1 0 VA 832 VA 1 20 A M GUH-3 4643 Spare -- 20 A 1 0 VA 1587... 1 20 A M GUH-2 4441 Spare -- 20 A 1 0 VA 1321... 4239 EF-4, 5, 6 M 20 A 1 1518... 1321... 4037 RADIENT HEATERS ... G 20 A 1 480 VA 1321...

3 15 A G PE-238

35 REC CLG - GFI R 20 A 1 180 VA 1036... 3633 REC CLG - GFI R 20 A 1 180 VA 1057... 3431 REC CLG - GFI R 20 A 1 180 VA 1062...

3 200 A L; R; G;M ELB

3229 REC CLG - GFI R 20 A 1 180 VA 150 VA 1 20 A G CARD READERS 3027 REC CLG - GFI R 20 A 1 180 VA 1127... 1 20 A M UH-2 2825 REC CLG - GFI R 20 A 1 180 VA 60 VA 1 20 A M CONTROLS CKT 2623 0 VA 900 VA 1 20 A R REC EAST BAY 2421 GARAGE DOOR

SOUTH M 20 A 20 VA 900 VA 1 20 A R REC SOUTH BAY 22

19 0 VA 1200... 1 20 A M CF-1 2017 GARAGE DOOR

SOUTH M 20 A 20 VA 506 VA 1 20 A M EF-3 18

15 0 VA 160 VA 1 20 A M UH-1 1613 GARAGE DOOR

SOUTH M 20 A 20 VA 794 VA 14

11 0 VA 794 VA2 20 A M EF-2

129 GARAGE DOOR

NORTH M 20 A 20 VA 1080... 1 20 A R REC NORTH WALL 10

7 920 VA 446 VA 1 20 A L LTG MEZANNINE 85 GARAGE DOOR

NORTH M 20 A 2920 VA 1411... 1 20 A L LTG EAST 6

3 0 VA 1168... 1 20 A L LTG BAY WEST 41 GARAGE DOOR

NORTH M 20 A 20 VA 1168... 1 20 A L LTG BAY EAST 2

Note Circ... Load Type Trip Po... A B C Po... Trip Type Load Circ... Note

Circuit Notes:Enclosure: Type 1 Feed:Mounting: Surface Wire: 4 Bus Rating: 400 A

Supply From: MDP Phase: 3 Mains Type: MLOLocation: BATHROOM 201 Voltage: 120/208 Wye A.I.C. Rating: 22K

New Panel ELA

** = Shunt Trip* = GFIBreaker Accessories

General Notes:O Other 0 VA 0% 0 VAE Existing 0 VA 0% 0 VA Total Demand Current: 593 AK Kitchen 0 VA 0% 0 VA Total Demand Load: 213481 VAG General 113565 VA 100% 113565 VAC Continuous 0 VA 0% 0 VA Total Connected Current: 640 AM Motor 54127 VA 108% 58310 VA Total Connected Load: 230698 VAR Receptacle 57289 VA 59% 33644 VAL Lighting 8046 VA 125% 10058 VA Power Factor:

Load Type Connected Load Demand Factor Demand Load Switchboard Totals% A-B % B-C % C-A

14 19 5624 A 711 A 596 A

74417 VA 84878 VA 71514 VA

ELA L; R; G; M 33980 VA 34021 VA 31722 VARTU-3 G 5404 VA 5404 VA 5404 VALB L; R; G; M 8563 VA 12929 VA 10797 VALA R; G; M 27387 VA 33426 VA 24464 VA

Load Type A B C Note

Circuit Notes:Feed: MCB Rating: 600 A

Mounting: Wires: 4 Bus Rating:Supply From: Phases: 3 Mains Type: MCB

Location: ELEC 136 Volts: 120/208 Wye A.I.C. Rating: 22K

Switchboard MDP

REVISIONS

Rev. # Description Date1 Addendum #2 10/18/2019

1

Charlene
colorado
Charlene
Typewritten Text
10/18/2019
Page 8: C:UsersCharleneDesktopCMOProjects 9190228 greeley fire

R

SEH ProjectChecked ByDrawn By

Project Status Issue Date

This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.

Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Shor

t Ellio

tt Hed

ricks

on, In

c.Al

l Righ

ts Re

serve

d

COPY

RIGH

T ©

2019

TechnologyBCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

DHM DESIGN900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group2525 South Wadsworth Blvd, Suite 200Lakewood, Colorado 80227303.988.4514

CMO Consuling Engineers, LLC11646 Sun Bear TrailGolden, Colorado 80403303.875.4037

10/17

/2019

5:49

:07 P

M

PANEL SCHEDULES

E402

GREE

LEY

FIRE

STA

TION

#2

2301

Res

ervo

ir Rd,

Gree

ley, C

O 80

634

18323.02

City

of Gr

eeley

100% CONSTRUCTIONDOCUMENTS

8/28/2019

** = Shunt Trip* = GFIBreaker Accessories

General Notes:O Other 0 VA 0% 0 VAE Existing 0 VA 0% 0 VA Total Demand Current: 84 AK Kitchen 0 VA 0% 0 VA Total Demand Load: 30088 VAG General 6433 VA 100% 6433 VAC Continuous 0 VA 0% 0 VA Total Connected Current: 87 AM Motor 7018 VA 110% 7694 VA Total Connected Load: 31517 VAR Receptacle 15620 VA 82% 12810 VAL Lighting 2791 VA 125% 3489 VA Power Factor: 0.8

Load Type Connected... Demand Factor Demand Load Panel TotalsPhase Balance: 0 % A-B 2 % B-C 3 % C-A

Total Amps: 89 A 88 A 86 ATotal Load: 10622 VA 10576 VA 10362 VA

59 Spare -- 20 A 1 0 VA 6057 Spare -- 20 A 1 0 VA 5855 Spare -- 20 A 1 0 VA 5653 Spare -- 20 A 1 0 VA 5451 Spare -- 20 A 1 0 VA 5249 Spare -- 20 A 1 0 VA 5047 Spare -- 20 A 1 0 VA 4845 Spare -- 20 A 1 0 VA 180 VA 1 20 A R REC MEC 4643 Spare -- 20 A 1 0 VA 720 VA 1 20 A R REC BUNK S 4441 Spare -- 20 A 1 0 VA 720 VA 1 20 A R REC BUNK N 4239 Spare -- 20 A 1 0 VA 540 VA 1 20 A R REC TV AREA 4037 MECH CONTROL CKT G 20 A 1 100 VA 540 VA 1 20 A R REC TV AREA 3835 90 VA 100 VA 1 20 A M FACP 3633

REC IT R 20 A 290 VA 100 VA 1 20 A G; M CARD READER 34

31 REC COUNTER/HOOD R; M 20 A 1 194 VA 180 VA 1 20 A R REC CATV 3229 REC COUNTER R 20 A 1 360 VA 180 VA 1 20 A R REC IT 3027 REC COUNTER R 20 A 1 360 VA 180 VA 1 20 A R REC IT 2825 REFRIG R 20 A 1 1000... 794 VA 2623 REFRIG R 20 A 1 1000... 794 VA

2 20 A M EF-124

21 REFRIG R 20 A 1 1000... 180 VA 1 20 A R REC IT 2219 REFRIG R 20 A 1 1000... 180 VA 1 20 A R REC IT 2017 REC RADIO RM R 20 A 1 720 VA 3063... 1815 REC MECH RM R; M 20 A 1 374 VA 3063...

2 30 A G; M ACCU-116

13 REC WATCH R 20 A 1 1080... 607 VA 1411 REC WATCH R 20 A 1 360 VA 607 VA

2 20 A M PUMP P112

9 REC COPIER R 20 A 1 1000... 1334... 1 20 A M CP-1, 2 107 REC WATCH RM... R 20 A 1 720 VA 1440... 1 20 A G BOILER 85 REC LT OFFICE R 20 A 1 1080... 1440... 1 20 A G BOILER 63 REC EXAM R 20 A 1 540 VA 1779... 1 20 A L LTG MAIN 41 REC PROGRAM... R 20 A 1 1080... 1014... 1 20 A L LTG WEST 2

Note Circ... Load Type Trip Po... A B C Po... Trip Type Load Circ... Note

Circuit Notes:Enclosure: Type 1 Feed:Mounting: Recessed Wire: 4 Bus Rating: 225 A

Supply From: ELA Phase: 3 Mains Type: MLOLocation: CORRIDOR 123 Voltage: 120/208 Wye A.I.C. Rating: 10K

New Panel ELB

** = Shunt Trip* = GFIBreaker Accessories

General Notes:O Other 0 VA 0% 0 VAE Existing 0 VA 0% 0 VA Total Demand Current: 75 AK Kitchen 0 VA 0% 0 VA Total Demand Load: 26978 VAG General 9464 VA 100% 9464 VAC Continuous 0 VA 0% 0 VA Total Connected Current: 89 AM Motor 978 VA 122% 1191 VA Total Connected Load: 32240 VAR Receptacle 21660 VA 73% 15830 VAL Lighting 1083 VA 125% 1354 VA Power Factor: 0.8

Load Type Connected... Demand Factor Demand Load Panel TotalsPhase Balance: 55 % A-B 19 % B-C 30 % C-A

Total Amps: 71 A 111 A 93 ATotal Load: 8563 VA 12929 VA 10797 VA

41 Spare -- 20 A 1 0 VA 4239 Spare -- 20 A 1 0 VA 4037 Spare -- 20 A 1 0 VA 3835 Spare -- 20 A 1 0 VA 3633 Spare -- 20 A 1 0 VA 3431 REC WEST BAY G 20 A 1 1000... 3229 REC DW G 20 A 1 750 VA 850 VA 1 20 A M REC DISPOSAL 3027 REC PARKING R 20 A 1 720 VA 720 VA 1 20 A R REC PARKING 2825 LTG EXT L 20 A 1 247 VA 840 VA 1 20 A L EXTERIOR LIGHT... 2623 3750... 180 VA 1 20 A R REC ROOF 2421

REC SOUTH BAY G 50 A 23750... 900 VA 1 20 A R REC WEST BAY 22

19 CUH-1 G 20 A 1 506 VA 1276... 1 20 A R; M REC DAY RM/TLT 2017 REC DW R 20 A 1 360 VA 360 VA 1 20 A R REC EXTERIOR... 1815 REC BUNK 113 R 20 A 1 1080... 556 VA 1 20 A R; M REC LOBBY 1613 REC BUNK 112 R 20 A 1 1080... 400 VA 1 20 A R; M TLT 119, 120 1411 REC BUNK 111 R 20 A 1 1080... 400 VA 1 20 A R; M TLT 117, 118 129 REC BUNK 110 R 20 A 1 1080... 1096... 1 20 A R; M REC CORR EF-14 107 REC BUNK 109 R 20 A 1 1080... 180 VA 1 20 A R REC LAUNDRY 85 REC BUNK 108 R 20 A 1 1080... 2500... 63 REC BUNK 107 R 20 A 1 1080... 2500...

2 35 A R DRYER4

1 REC BUNK 106 R 20 A 1 1080... 1000... 1 20 A R WASHER LAUNDRY 2Note Circ... Load Type Trip Po... A B C Po... Trip Type Load Circ... Note

Circuit Notes:Enclosure: Type 1 Feed:Mounting: Recessed Wire: 4 Bus Rating: 225 A

Supply From: MDP Phase: 3 Mains Type: MLOLocation: CORRIDOR 123 Voltage: 120/208 Wye A.I.C. Rating: 10K

New Panel LB

REVISIONS

Rev. # Description Date

Charlene
colorado
Charlene
Typewritten Text
10/18/2019
Page 9: C:UsersCharleneDesktopCMOProjects 9190228 greeley fire

NOTES:

CL FLUSH LATCH AND LOCK

CONCEALED HINGE (TYPICAL)

PIANO HINGE FOR FLUSH MOUNTED PANELS

TWO LOCKS IF INNER DOOR IS OVER 36" HIGH.

1/4-20-LARGE HEAD SLOTTED SCREWS (TYPICAL)

1. ALL BOLTS SHALL HAVE LARGE (3/8") ROUND HEAD. NO WASHERS ALLOWED2. TYPICAL FOR ALL 120/208V BRANCH PANELBOARDS.

NO SCALEHINGED TRIM TO BOX PANEL FRONT

SINGLE GANG PLASTER RING WITHGROUND SCREW AND PIGTAIL TO MATCHDRYWALL THICKNESS

4" SQ COMBO BOX

NO SCALERECEPTACLE BOX SUPPORT DETAIL

TOP OF CABINET

TOP OF CABINET

80" (

6'-8"

) OR

6" B

ELO

W C

EILI

NG W

HICH

EVER

IS L

OW

ER

84" (

7'-0"

) UO

N

96" (

8'-0"

) UO

N

72" (

6'-0"

) UO

N

78" (

6'-6"

) UO

N

54" (

4'-6"

) UO

N

42" (

3'-6"

) UO

N

64" (

5'-4"

) UO

N

TYPICAL 9'-0" CEILING OR HIGHER

TOP OF CABINET

TYPICAL 8'-0" CEILING

2.

3.

NOTES:1.

FINISHED FLOOR18" (

1'-6"

) UO

N

NOTE: ALL DEVICES INDICATED TO BEINSTALLED AT DIFFERENT MOUNTINGHEIGHTS AND LOCATED WITHIN ONESTUD SPACE FROM EACH OTHERSHALL ALIGN VERTICALLY, ON THESAME SIDE OF THE STUD. WHERE WALLMOUNTED TELEPHONES OCCUR OVERLIGHT SWITCHES, VOLUME CONTROLS,ETC. OFFSET ONE STUD SPACE.

HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE.

WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND CEILING LINE.

MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE.

BOTTOM OF DEVICE

W

GFI

GZM

PB P P

CONTROL PANELS

TOPS

TOPS

PC

C

C

B

B

FAA

C

C

MDC

C

E

MD

C

C

FACP

S

CR

D CB E1 2 S

V

T TC

SSM

I

M

NO SCALE

F

TYPICAL DEVICE MOUNTING HEIGHTS

NOTES:1. SEE SPECIFICATIONS FOR ADDITIONAL NAMEPLATE INFORMATION.

2. REWORD NAMEPLATE FOR FIELD CONDITIONS.

3. AMP RATING SHALL INDICATE BUS RATING.

SCALE: FULL

PANEL L1A

22,000 AIC

120/208V 3Ø, 4W, 225AFED FROM MDC

SUB-DISTRIBUTION CENTER AND BRANCH PANELBOARD NAMEPLATE DETAIL

PH A - BLACK; PH B - RED; PH C - BLUE GROUND - GREEN

4" SQ. X 1 5/8"D BOX4"

16"

8"

8"

2" DEEP BLOCK RING, SINGLE GANG OR TWO GANG RING, AS REQUIRED.

4" SQ. X 1 5/8"D EXTENSION RING

BOX DETAIL FOR BLOCK WALL INSTALLATIONSCALE: 3"=1'-0"

NOTES:

2.1. SEE SPECIFICATIONS FOR ADDITIONAL NAMEPLATE INFORMATION.

REWORD NAMEPLATE FOR FIELD CONDITIONS.

WARNING

Appropriate PPE Required

ARC FLASH NAMEPLATE DETAIL

Arc Flash and Shock Hazard

SCALE: NONE

11 in0.55 cal/cm2

PPE

480 VAC0042 in12 inN/A

Flash Risk BoundaryFlash Risk at: 18 in

Shirt & pants or coverall, Nonmelting (ASTM F1506) or Untreated FiberShock Risk when cover is removedGlove ClassLimited ApproachRestricted ApproachMinimum Arc Rating

Bus: Panel A Prot: CB Panel A

NOTES:1. SEE SPECIFICATIONS FOR ADDITIONAL NAMEPLATE INFORMATION.

2. REWORD NAMEPLATE FOR FIELD CONDITIONS.

3. HP SHALL INDICATE HORSEPOWER.

EQUIPMENT NAMEPLATE DETAIL

EXHAUST FAN #1

480V 3Ø HPFED FROM H1A

SCALE: FULL

C.

B.

A. TAG ALL GROUNDING ELECTRODE CONDUCTORS AND ASSOCIATED BONDING CONDUCTORS AT THEIR POINT OF ATTACHMENT TO GROUND BUS AND GROUNDING ELECTRODE (WHERE POSSIBLE) WITH A ROUND WHITE CORE. GREEN PHENOLIC NAMEPLATE AS SHOWN IN DETAIL 'A'.

IDENTIFY ABOVE REFERENCED CONDUCTORS WITH 6" BAND OF GREEN TAPE AT EACH END AND AT 10'INTERVALS WHERE RUN EXPOSED. STENCIL CONDUITS CONTAINING THESE CONDUCTORS "MAIN GROUND" IN GREEN KROY LETTERS. 1/2" DIAMETER OF CONDUIT IN HEIGHT.

SHOW GROUNDING ELECTRODE SYSTEM CONNECTIONS BY IDENTIFYING (ON THE RECORD DRAWING MARK-UPS) WHERE (ROOM NO. AND/OR NAME) AND TO WHAT (ROD, WATER PIPE, GROUND BUS, ETC.) THEY TERMINATE.

ALL GROUNDING WORK DONE UNDER THIS CONTRACT SHALL INCLUDE THE FOLLOWING UNLESS SPECIFICALLY EXCLUDED:

1/4" HIGH LETTERING WITH MINIMUM OF 1/8" BETWEEN LINES. CENTERED IN TAG.

2" DIA. WHITE CORE GREEN PHENOLIC GROUND TAG

1/8" DIA. HOLE TO ACCEPTCHAIN FOR ATTACHMENT TO CONDUCTOR.

PROVIDE SUFFICIENT CHAIN TO ATTACH TO CONDUCTOR.

DO NOTDISCONNECT

MAINGROUND TO

COLDWATER PIPE

NO SCALEGROUND CONDUCTOR TAG DETAIL

AIRFLOW DIRECTION

INSERT RUBBER PLUG THIS END OF INLET TUBE.

INLET TUBE HOLES FACE UPSTREAM OF AIRFLOW.

TUBE SUPPORT HOLE ONLY FOR DUCTS MORE THAN 3' WIDE

EXPECTED AIRFLOW DIRECTION

RETURN TUBE SLANT CUT FACE ORIENTED DOWN-STREAM OF AIRFLOW. DO NOT INSERT RUBBER PLUG.

DUCT WIDTH

NO SCALEDUCT DETECTOR DETAIL

NO SCALETYPICAL FIRE/SMOKE DAMPER CONTROL WIRING DIAGRAM

TYPICAL FIRE/SMOKE DAMPERGENERAL NOTES:

TYPICAL FIRE/SMOKE DAMPER DETAIL NOTES:

1

SMOKE DETECTOR FSD

2.

SEE MECHANICAL PLAN DRAWING FOR ACTUAL LOCATION AND QUANTITIES OF DAMPERS.

PROVIDE CONTROL MODULE AT EACH FSD DETECTOR DEVICE AS REQUIRED.

ELECTRIC/PNEUMATIC SWITCH OR ELECTRIC DAMPER OPERATOR(TYPICAL). EP SWITCH PROVIDED WITH DAMPEROPERATOR. PROVIDE LOCAL DISCONNECT.

CONNECT CONTROL MODULES AND DETECTORS TO FACP FOR ALARM AND ANNUNCIATION SEPARATE FROM DAMPER CONTROL WIRING.

COORDINATE AND PROVIDE CEILING/WALL ACCESS DOORS TO DUCT DETECTORS WHERE REQUIRED.

PROVIDE CLOSURE OF ALL ASSOCIATED FIRE/SMOKE DAMPERS ON AIR MOVING EQUIPMENT SHUTDOWN. PROVIDE MONITOR MODULE AT EACH UNIT RELATED TO THE DAMPERS TO MONITOR RUN STATUS OF UNIT VIA AUXILIARY CONTACTS IN STARTER/VFD. PROVIDE CONDUIT, WIRING AND CONNECTIONS.

COORDINATE AND PROGRAM AIR MOVING EQUIPMENT SHUTDOWN TO AHU'S UPON CLOSURE OF AN ASSOCIATED FIRE/SMOKE DAMPER WHERE NOTED ON MECHANICAL DRAWINGS AND/OR IN SPECIFICATIONS.

1.120 VOLT SOURCE

DAMPER LOCATED IN UNDUCTED OPENINGIN WALL OR IN A CEILING: A TYPICAL

SINGLE FIRE/SMOKE DAMPER CONTROLLEDBY A LOCAL SMOKE DETECTOR MTD.

WITHIN 5'-0" HORIZONTALLY OF DAMPER.ACTIVATION OF SMOKE DETECTOR SHALL

OPEN CONTACT AND CLOSE DAMPER.

DAMPER LOCATED WITHIN DUCT: ATYPICAL FIRE/SMOKE DAMPER

CONTROLLED BY DUCT DETECTORLOCATED WITHIN 5'-0"

HORIZONTALLY OF THE DAMPER INASSOCIATED DUCT. ACTIVATION OF

DUCT DETECTOR ALARM SHALLOPEN CONTACT AND CLOSE DAMPER.

2

AIR MOVING EQUIPMENTSTARTER/VFD ADDITIONAL STARTERS/VFD'S FOR

UNITS SERVING THE SAME SPACE

FIRE ALARMCONTROL MODULE

FIRE ALARMDUCT DETECTORAUXILIARY CONTACT

2

3

4

5

4 5

AIM AIM AIM

2

AOM

1

P

FSD

S

1

1

S

23

RTS S/RFSD

~~

~~

~~

R

SEH ProjectChecked ByDrawn By

Project Status Issue Date

This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.

Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Shor

t Ellio

tt Hed

ricks

on, In

c.Al

l Righ

ts Re

serve

d

COPY

RIGH

T ©

2019

TechnologyBCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

DHM DESIGN900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group2525 South Wadsworth Blvd, Suite 200Lakewood, Colorado 80227303.988.4514

CMO Consuling Engineers, LLC11646 Sun Bear TrailGolden, Colorado 80403303.875.4037

10/17

/2019

5:49

:08 P

M

ELECTRICAL DETAILS

E501

GREE

LEY

FIRE

STA

TION

#2

2301

Res

ervo

ir Rd,

Gree

ley, C

O 80

634

18323.02

City

of Gr

eeley

100% CONSTRUCTIONDOCUMENTS

8/28/2019

REVISIONS

Rev. # Description Date

Charlene
colorado
Charlene
Typewritten Text
10/18/2019
Page 10: C:UsersCharleneDesktopCMOProjects 9190228 greeley fire

PVC COVERED FLEXIBLE CONNECTIONCONTAINING POWER CIRCUIT & GROUNDWIRES, PROVIDE EXTRA SLACK TO ALLOWROTATING MOTOR 90° FOR MAINTENANCEWITHOUT BREAKING ELECTRICAL CONNECTION.

NOTE: SEE SPECIFICATIONS FOR ADDITIONAL SUPPORT, SEISMIC AND OTHER REQUIREMENTS.

FLANGES FASTENED TO FLOOR

FINISHED FLOOR

2 PIPE SUPPORT OR TWO UNISTRUTHEAVY GUAGE CHANNELS.

DISCONNECT SWITCH WHERE SHOWNADJACENT ON PLAN, SIZE PER MECHANICALEQUIPMENT SCHEDULE-MOUNT SECURELY.

CONDUIT FROM MOTOR STARTERCONTAINING POWER AND GROUND WIRE

NO SCALE

CONNECTION TO FLOOR MOUNTED MOTORS

NOTES:INSTALL 20' MINIMUM/40' MAXIMUM UFER GROUND CONDUCTOR IN EACH DIRECTION. PROVIDE BARE COPPER CONDUCTOR SIZED PER NEC TABLE 250-94 OR AS INDICATED ON THE DRAWINGS (#4 AWG SHALL BE THE MINIMUN SIZE).ROUTE UFER GROUND CONDUCTOR, THROUGH PVC CONDUIT SLEEVE.AVOID CONTACT WITH RE-BAR IN CONCRETE. DO NOT TIE DIRECTLY TO RE-BAR, USE SEPARATOR APPROVED BY STRUCTURAL.COORDINATE ACTUAL UFER GROUND CONDUCTOR INSTALLATION WITH STRUCTURAL.

RUN UFER GROUND IN PVC CONDUIT SLEEVE FROM WHERE IT EXITS THE GRADE BEAM.

4.

3.

1.

2.

4" VOID CONT. TYP.

CONCRETE GRADE BEAM

GRADE

RE-BAR, TYP.

SECTION VIEW

ELEVATION VIEW

2" MINIMUM COVER TO UFER GROUND CONDUCTOR

20' MINIMUM/40' MAXIMUM

GRADE BEAMUFER GROUND

PVC CONDUIT SLEEVE

UFER GROUND

TO MAIN GROUND BAREXOTHERMIC WELD OR ROUTE BOTH CONDUCTORS TO MAIN GROUND BAR

NO SCALEUFER GROUND DETAIL

CONDUCTORS PER NEC 250.94SYSTEM GROUNDING ELECTRODE

L3

SOURCEPOWERMAIN

L1L2

GFP SENSOR WHERE REQUIRED

SERVICE ENTRANCE RATED MAIN CIRCUIT BREAKER OR SWITCH

GROUND

TO LOAD 'T3'TO LOAD 'T2'TO LOAD 'T1'

NEUT

3 POLE ATS

GEN

EL3NEUT

EL1EL2

GENERATOR MOUNTED MAIN CIRCUIT BREAKER

GNDNEUT

NO SCALE

GENERATOR GROUNDING DETAIL3 POLE TRANSFER SWITCH

NO SCALEPOLE BASE DETAIL - RAISED

FINISH GRADE

ANCHOR BOLTS INSTALLED PER MANUFACTURERS BOLT TEMPLATE

18"

60"

24"

HAND HOLE WITH FLUSH COVERBOND TO GROUND WITHIN POLE

#6 BARE COPPER GROUNDBASE COVER

SITE LIGHTING POLE; REFER TO PLAN AND LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION

BRANCH CONDUIT

24" MIN.

#4 TIE WIRES @ 12"O.C.

4#4 REBAR WELDED TO ANCHORBOLTS

ROUND CONCRETE BASE CON. MIN.STRENGTH 3000LBS @28 DAYS.

120V RECEPTACLE .

5/8" X 10' COPPER GROUND ROD WITH THERMOWELD BARE #6 WIRE TO GROUND LUG.

NOTE:TRAPEZE SHALL BE PROVIDEDWHEREVER TWO OR MORERACEWAYS ARE RUN ADJACENT.

FUTURE STRUT TO BE ATTACHED TO EXISTING STRUT

NOTE: SEE SPECIFICATIONS FOR ADDITIONALSUPPORT, SEISMIC AND OTHER REQUIREMENTS.

U-CHANNEL STRUT

SPACE FOR FUTURE RACEWAYS

1/2 WMIN.

WRACEWAYS INSTALLED AS PART OF THIS CONTRACT SHALL BE ATTACHED TO TOP OF STRUT WITH APPROVED U-CHANNEL STRUT FASTENER

STEEL ALL THREADPER SPECS

ATTACHED TO STRUCTURE AS REQUIRED

NO SCALETRAPEZE DETAIL

BRANCH WIRING

GRADE

PEDISTAL

ANCHOR BOLTS INSTALLED PER MANUFACTURERS BOLT TEMPLATE

3#4 FULL HEIGHT WITH #3 TIES AT 24O.C. TYPE II, 3000 PSI CONCRETE

X"

Y"

NO SCALEEXTERIOR PEDISTAL DETAIL

R

SEH ProjectChecked ByDrawn By

Project Status Issue Date

This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.

Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Shor

t Ellio

tt Hed

ricks

on, In

c.Al

l Righ

ts Re

serve

d

COPY

RIGH

T ©

2019

TechnologyBCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

DHM DESIGN900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group2525 South Wadsworth Blvd, Suite 200Lakewood, Colorado 80227303.988.4514

CMO Consuling Engineers, LLC11646 Sun Bear TrailGolden, Colorado 80403303.875.4037

10/17

/2019

5:49

:09 P

M

ELECTRICAL DETAILS

E502

GREE

LEY

FIRE

STA

TION

#2

2301

Res

ervo

ir Rd,

Gree

ley, C

O 80

634

18323.02

City

of Gr

eeley

100% CONSTRUCTIONDOCUMENTS

8/28/2019

REVISIONS

Rev. # Description Date

Charlene
colorado
Charlene
Typewritten Text
10/18/2019
Page 11: C:UsersCharleneDesktopCMOProjects 9190228 greeley fire

R

SEH ProjectChecked ByDrawn By

Project Status Issue Date

This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc. (SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.

Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.

Architect/ Civil Engineer/ Structural

Landscape Architect

Mechanical Engineer

Electrical Engineer

Owner

Short Elliott Hendrickson, Inc.2000 South Colorado BoulevardTower One, Suite 6000Denver, Colorado 80222720.540.6800

Shor

t Ellio

tt Hed

ricks

on, In

c.Al

l Righ

ts Re

serve

d

COPY

RIGH

T ©

2019

TechnologyBCER Engineering Inc5420 Ward RdArvada, CO 80002303.422.7400

City of Greeley1000 10th StreetGreeley, Colorado 80631970.350.9777

DHM DESIGN900 South BroadwayDenver, Colorado 80209303.892.5566

The Ballard Group2525 South Wadsworth Blvd, Suite 200Lakewood, Colorado 80227303.988.4514

CMO Consuling Engineers, LLC11646 Sun Bear TrailGolden, Colorado 80403303.875.4037

10/17

/2019

5:49

:11 P

M

COMCHECK

E503

GREE

LEY

FIRE

STA

TION

#2

2301

Res

ervo

ir Rd,

Gree

ley, C

O 80

634

18323.02

City

of Gr

eeley

100% CONSTRUCTIONDOCUMENTS

REVISIONS

Rev. # Description Date1 Addendum #2 10/18/2019

1

Charlene
colorado
Charlene
Typewritten Text
10/18/2019