cts – © 1995 – 2005 smarsystem302 system302 asset view system302

62
CTS – © 1995 – 2005 Smar System302 SYSTEM302 SYSTEM302 ASSET VIEW ASSET VIEW

Upload: agustina-mascarenhas-lameira

Post on 07-Apr-2016

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

SYSTEM302SYSTEM302

ASSET VIEWASSET VIEW

Page 2: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Ferramenta de GerenciamentoFerramenta de Gerenciamento

Online de Ativos via WebOnline de Ativos via Web

ASSETVIEW

Sistema de Asset Management que possibilita o gerenciamento Sistema de Asset Management que possibilita o gerenciamento contínuo dos instrumentos on-line, via redes Fieldbus, Hart e contínuo dos instrumentos on-line, via redes Fieldbus, Hart e Ethernet.Ethernet.

Page 3: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

FuncionamentoFuncionamento

REDE ETHERNET

DFI 302

H1H1 . . .

HI 302

REDE FIELDBUS

. . .

REDE HART

até 32 devices Hart

ASSETVIEW

Page 4: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

O que o AssetView faz:O que o AssetView faz: Identificação,Calibração, Configuração e Monitoração de

Devices Fieldbus,Hart, Smar e outros fabricantes Armazenamento de Dados Eventos de Diagnóstico Manutenção Planejada (Preventiva, Preditiva, Corretiva e

Proativa), com notificações por e-mail Gráficos com características on-line do equipamento Reconciliação (Histórico dos estados de configuração do

equipamento) Device Library (Base de conhecimento) Audit Trail Report

ASSETVIEW

Page 5: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Monitoração e Monitoração e Armazenamento de Dados:Armazenamento de Dados:

PLANTA

PV - over pressure (LD) Alarmes, Mudança de configuração,

Reversos (válvulas) Strokes (válvulas), km (válvulas) Tempo para Fechar e Abrir (válvulas) Status (G/B) , Comunicação Suprimento de Ar / pressão alta ou errada Desvios, Temperatura, Sensor

Monitoração

Armazenamento de dados

Armazena todos os parâmetros monitorados (estáticos) Eventos de Diagnósticos, Manutenções efetuadas Calibrações efetuadas, Data Sheet do instrumento Histórico de tags do instrumento Histórico dos instrumentos com determinado Tag Levantamento As found as Left Step response Valve Signature Caracterização Histerese Travel deviation

Database

ASSETVIEW

Page 6: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Diagnósticos:Diagnósticos: Todos os itens monitorados podem ser utilizados para

diagnóstico designando condições limites pelo usuário.

Exemplos:Exemplos: Slow/Stickey Movement (FY) Falha de Memória Pressão Máxima Temperatura Máxima Zero Shift (Offset) Actual Span Sensor Simulation (TT,FY) active Temperatura - Out of range

ASSETVIEW

Page 7: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Falha de saída (FY) Status G/B Erro de configuração do Bloco Erro de configuração dos Links Local Override Device Fault Perda de Dados Bloco fora de serviço Erro de Calibração Erro de Configuração Falha de componente eletrônico Módulo mecânico não conectado (FY) Integridade de dados Erro de software Redundância ativada (TT) Dual sensor activation (TT) Simulador ativado (FY)

Outros Exemplos (Diagnóstico):Outros Exemplos (Diagnóstico):

ASSETVIEW

Page 8: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Eventos de Diagnósticos:Eventos de Diagnósticos:Monitoração

Evento de Diagnóstico

Usuário com o browser aberto

Armazenamento de dados

ASSETVIEW

Page 9: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Diagnostic ViewDiagnostic ViewASSETVIEW

Page 10: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção PlanejadaManutenção Planejada

CorretivaCorretiva

PreventivaPreventiva

PreditivaPreditiva

ProativaProativa

CustoCusto

ASSETVIEW

Page 11: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção Corretiva:Manutenção Corretiva:

Realizada quando o instrumento quebra.Realizada quando o instrumento quebra.

ASSETVIEW

Page 12: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção Preventiva:Manutenção Preventiva:

Realizada de tempo em tempo.Realizada de tempo em tempo.

O período é definido pelo fabricante do instrumento.O período é definido pelo fabricante do instrumento.

ASSETVIEW

Page 13: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção Preditiva:Manutenção Preditiva:

Realizada de tempo em tempo.Realizada de tempo em tempo.

O período é definido pelas condições de uso do processo O período é definido pelas condições de uso do processo armazenadas, formando uma “Base de Conhecimento”.armazenadas, formando uma “Base de Conhecimento”.

Base deConhecimento

ASSETVIEW

Page 14: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

O que seria esta Base de Conhecimento?O que seria esta Base de Conhecimento? A Base de Conhecimento é um conjunto de

informações adquiridas ao longo do tempo pelo monitoramento da planta.

É feito o monitoramento contínuo e registro das variáveis de cada instrumento em condições reais de operação.

Base deConhecimento

Resultado:Resultado:

É possível avaliar com maior precisão qual o tempo provável que cada instrumento pode operar antes de necessitar de uma manutenção.

ASSETVIEW

Page 15: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção Proativa:Manutenção Proativa:Manutenção baseada nos eventos de diagnósticos que avisam o Manutenção baseada nos eventos de diagnósticos que avisam o usuário quando algum componente do instrumento está prestes usuário quando algum componente do instrumento está prestes a falhar.a falhar.

CorretivaCorretiva PreventivaPreventiva PreditivaPreditiva ProativaProativa

CustoCusto

ASSETVIEW

Page 16: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção Proativa Como funciona?Manutenção Proativa Como funciona?

Base deConhecimento

IFIF

Evento de DiagnósticoEvento de Diagnóstico

Geração da Manutenção ProativaGeração da Manutenção Proativa

ACKACK

ASSETVIEW

Page 17: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção Corretiva (1/3):Manutenção Corretiva (1/3):ASSETVIEW

Page 18: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção Corretiva (2/3):Manutenção Corretiva (2/3):ASSETVIEW

Page 19: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção Corretiva (3/3):Manutenção Corretiva (3/3):

ASSETVIEW

Page 20: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção Preventiva:Manutenção Preventiva:

A programação das manutenções preventivas de A programação das manutenções preventivas de cada item do instrumento é feita automaticamente cada item do instrumento é feita automaticamente baseada nas informações fornecidas pelo fabricante baseada nas informações fornecidas pelo fabricante do instrumento.do instrumento.

ASSETVIEW

Page 21: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção PreventivaManutenção PreventivaProgramação – Tela Típica (1/2):Programação – Tela Típica (1/2):

ASSETVIEW

Page 22: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção PreventivaManutenção PreventivaProgramação – Tela Típica (2/2):Programação – Tela Típica (2/2):

ASSETVIEW

Page 23: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção PreventivaManutenção PreventivaNotificações das manutenções programadasNotificações das manutenções programadas

Uma mudança no ícone da manutenção avisa que existem manutenções pendentes.

Link para a página de manutenção.

A cor indica a severidade do alarme:Verde: Somente um aviso prévio.Amarelo: Data limite para a execução da manutenção.Vermelho: A data da manutenção já expirou.

ASSETVIEW

Page 24: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção PreditivaManutenção Preditiva

A sua programação no AssetView é feitaA sua programação no AssetView é feitade forma semelhante à manutenção preventiva.de forma semelhante à manutenção preventiva.A manutenção preditiva é o resultado daA manutenção preditiva é o resultado dainteração entre as sugestões de manutençõesinteração entre as sugestões de manutençõespelo fabricante com o uso específico dopelo fabricante com o uso específico doequipamento na planta.equipamento na planta.

ASSETVIEW

Page 25: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção ProativaManutenção Proativa Monitora, em tempo real, todos os parâmetros Monitora, em tempo real, todos os parâmetros fundamentais para a detecção de problemas em fundamentais para a detecção de problemas em cada um dos instrumentos da planta.cada um dos instrumentos da planta.

Desta forma, é possível identificar potenciais Desta forma, é possível identificar potenciais problemas antes que eles apareçam. problemas antes que eles apareçam.

Isto significa que o sistema sugere a manutenção Isto significa que o sistema sugere a manutenção quando ela realmente for necessária.quando ela realmente for necessária.

ASSETVIEW

Page 26: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção ProativaManutenção Proativa

É a mais rentável e eficiente, pois consegue chegar no limite É a mais rentável e eficiente, pois consegue chegar no limite de utilização do instrumento.de utilização do instrumento.

Diminui o custo relacionado às paradas não programadas.Diminui o custo relacionado às paradas não programadas.

ASSETVIEW

Page 27: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção ProativaManutenção ProativaLista de eventos de diagnósticosLista de eventos de diagnósticos

Exibe detalhes a respeito do evento.

Link para a página do device.

Reconhecimento: Desabilita a condição de alarme na topologia.

Imprime a lista de eventos de diagnóstico (Relatório).

ASSETVIEW

Page 28: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção ProativaManutenção ProativaInstrumentos que estão sendo monitoradosInstrumentos que estão sendo monitorados

ASSETVIEW

Page 29: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção ProativaManutenção ProativaTopologia e estado do instrumentoTopologia e estado do instrumento

Instrumento com problemas de comunicação.

Instrumento com eventos de diagnóstico.

Instrumento intencionalmente desconectado.

ASSETVIEW

Page 30: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção ProativaManutenção Proativa

Visão global dos estados dos instrumentosVisão global dos estados dos instrumentos

Condição normal - Nenhuma ocorrência.

Um ou mais Devices monitorados apresentam problemas de comunicação.

Um ou mais Devices receberam eventos de diagnóstico.

ASSETVIEW

Page 31: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção ProativaManutenção ProativaAutodiagnósticoAutodiagnóstico

Quando o instrumento inteligente detecta queQuando o instrumento inteligente detecta queestá ocorrendo alguma falha em alguns de seusestá ocorrendo alguma falha em alguns de seuscomponentes ou detecta que alguma condiçãocomponentes ou detecta que alguma condiçãooperacional foi atingida, ele notifica o sistemaoperacional foi atingida, ele notifica o sistemacom eventos de autodiagnóstico.com eventos de autodiagnóstico.

ASSETVIEW

Page 32: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção ProativaManutenção Proativa

Monitoração da condição operacionalMonitoração da condição operacional

ASSETVIEW

Page 33: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção ProativaManutenção ProativaCondição operacional atingidaCondição operacional atingida

ASSETVIEW

Page 34: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção ProativaManutenção Proativa

Condição de falhaCondição de falha

ASSETVIEW

Page 35: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Manutenção ProativaManutenção ProativaCondição de falhaCondição de falha

ASSETVIEW

Page 36: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

CalibraçãoCalibração

Execução de Métodos

ASSETVIEW

Page 37: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

CalibraçãoCalibração

ASSETVIEW

Page 38: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

CalibraçãoCalibraçãoAuto SetupAuto Setup

ASSETVIEW

Page 39: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

ConfiguraçãoConfiguraçãoASSETVIEW

Page 40: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

ConfiguraçãoConfiguraçãoReconciliaçãoReconciliação

ASSETVIEW

Page 41: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

IdentificaçãoIdentificação

ASSETVIEW

Page 42: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Outras ferramentas...Outras ferramentas...

ASSETVIEW

Page 43: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Como gerenciar um instrumento?Como gerenciar um instrumento?ASSETVIEW

Page 44: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Device LibraryDevice LibraryBiblioteca de InstrumentosBiblioteca de Instrumentos

ASSETVIEW

Page 45: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Device LibraryDevice LibraryImagensImagens

ASSETVIEW

Page 46: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Audit TrailAudit Trail

ASSETVIEW

Page 47: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Audit TrailAudit TrailAlterações de ConfiguraçãoAlterações de Configuração

ASSETVIEW

Page 48: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Notificações via e-mailNotificações via e-mailASSETVIEW

Page 49: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Device List – Tag SearchDevice List – Tag SearchASSETVIEW

Page 50: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Maintenances ListMaintenances List

ASSETVIEW

Page 51: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Maintenances AlarmsMaintenances Alarms

ASSETVIEW

Page 52: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Maintenances HistoryMaintenances HistoryASSETVIEW

Page 53: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Maintenances HistoryMaintenances HistoryASSETVIEW

Page 54: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

DeviceDevice· TAG: indica o tag associado ao posicionador na planta física. O tag pode ter até 32 caracteres.

· DEVICE ID: indica o código de identificação do posicionador. Este código pode ter até 32 caracteres.

· SW REVISION: indica a revisão de software do posicionador.

· HARDWARE REVISION: indica a revisão de hardware do posicionador.

· MANUFACTURER: identifica o fabricante do posicionador.

· DEVICE TYPE: identifica o tipo do posiciondaor para um fabricante específico.

· DEVICE REVISION: indica a revisão do posicionador.

· DD REVISION: indica a revisão da DD.

· DEVICE SERIAL NUMBER: indica o número serial do posicionador.

· MAIN BOARD SERIAL NUMBER: indica o número serial da placa eletrônica principal.

· MODULE SERIAL NUMBER: indica o número serial do módulo transdutor do posicionador.

· ORDERING CODE: indica o código de pedido do posicionador.ActuatorActuator· ACT MAIN ID: indica o número de identificação do fabricante do atuador.

· ACT MODEL NUM: indica o número de identificação do modelo do atuador.

· ACTUATOR SERIAL NUMBER: indica o número de série do atuador.ValveValve· VALVE MAN ID: indica o número de identificação do fabricante da válvula.

· VALVE MODEL NUM: indica o número de identificação do modelo da válvula.

· VALVE SERIAL NUMBER: indica o número de série da válvula.

Page 55: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Deviation AlertDeviation AlertDEVIATION ENABLE: possibilita verificar a diferença entre a posição atual da válvula e o set point desejado. Se esta diferença exceder a zona morta por mais do que um determinado tempo, um alarme será gerado e permanecerá ativado até que esta diferença diminua.

DEVIATION TIME: define o tempo (em segundos). A válvula deve exceder a zona morta durante este período antes que o alarme seja ativado.

DEVIATION DEAD BAND: indica a magnitude do valor de desvio da válvula (em porcentagem). Um alarme é gerado quando a válvula excede este valor durante um determinado tempo.

Travel Accum AlertTravel Accum AlertTRAVEL (hodômetro): indica o número equivalente de deslocamentos totais. O hodômetro é incrementado quando o número de mudanças excede o valor da zona morta. É usado para indicar que o diafrágma precisa ser substituído e o atuador revisado.

TRAVEL ENABLE: possibilita verificar a diferença entre o hodômetro e um limite pré-estabelecido. Um alame é gerado quando o hodômetro excede este limite.

TRAVEL LIMIT: indica o valor limite do hodômetro. Um alarme é gerado quando o hodômetro excede este limite. Digite um valor inferior ao limite do hodômetro para reconhecer o alarme.

TRAVEL DEAD BAND: indica a magnitude do valor do movimento da válvula (em porcentagem). Este valor é usado para incrementar o hodômetro.

Reversal AlertReversal AlertREVERSAL: indica o número de vezes que a válvula muda de direção quanto ao movimento. O total de reversos é incrementado quando a válvula muda de direção e o total de movimentos excede a zona morta.

REVERSAL ENABLE: possibilita verificar a diferença entre o número de reversos e um limite pré-estabelecido. Um alarme é gerado quando o número de reversos excede este limite.

REVERSAL LIMIT: indica o limite do número de reversos. Um alarme é gerado quando o número de reversos excede este limite. Digite um valor menor que o limite de reversos para reconhecer o alarme.

REVERSAL DEAD BAND: indica a magnitude do valor do movimento da válvula (em porcentagem). Este valor é usado para incrementar o número de reversos.

Page 56: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Sensor Pressure AlertSensor Pressure AlertToda vez que a pressão de entrada ultrapassa o limite, um alarme é gerado.

· SENSOR PRESSURE IN HIGH LIMIT: indica o limite da pressão máxima de entrada.

· SENSOR PRESSURE IN LOW LIMIT: indica o limite da pressão mínima de entrada.

Travel ControlTravel ControlAs condições de excursão da válvula dependerão dos parâmetros relacionados abaixo.

· CHARACTERIZATION TYPE: tipo de caracterização da válvula.

o LINEAR: a posição real será representada por um gráfico linear em relação a posição desejada.

o TABLE: o usuário pode caracterizar as posições reais em função da aplicação.

o EP25, EP33, e EP50: as curvas EP (Equal Percentage) fornecem excursão maior somente para grandes variações de set point.

o QO25, QO33, e QO50: as curvas QO (Quick Open) fornecem uma excursão maior para pequenas variações de set point.

· FINAL VALUE CUTOFF LOW: se o FINAL_VALUE for menor do que este valor, a válvula será forçada a fechar totalmente. O FINAL_VALUE é o valor da posição desejada.

· FINAL VALUE CUTOFF HIGH: se o FINAL_VALUE for maior que este valor, a válvula será forçada a abrir totalmente. O FINAL_VALUE é o valor da posição desejada.

· TRAVEL LIMIT LOW: limite inferior do hodômetro.

· TRAVEL LIMIT HIGH: limite superior do hodômetro.

Page 57: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Valve TotalsValve Totals· STROKES: indica o número de vezes que a válvula abre e fecha totalmente.· REVERSALS: indica o número de vezes que a válvula muda de direção de acordo com o movimento. O número de reversos é incrementado quando a válvula muda de direção e o número de movimentos excede a zona morta.· TRAVEL (hodômetro): indica o número equivalente de deslocamentos totais. O hodômetro é incrementado quando o número de mudanças excede o valor da zona morta. É usado para indicar que o diafrágma precisa ser substituído e o atuador revisado.

Valve PerformanceValve Performance· CLOSING TIME: indica o tempo (em segundos) que a válvula leva para ir de totalmente aberta para totalmente fechada. Este tempo é usado para indicar um problema com o atuador, rompimento do diafrágma e problemas com o tubo de ar.· OPENING TIME: indica o tempo (em segundos) que a válvula leva para ir de totalmente fechada para totalmente aberta. Este tempo é usado para indicar um problema com o atuador, rompimento do diafrágma e problemas com o tubo de ar.

Page 58: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

TemperatureTemperature· HIGHEST TEMPERATURE: indica o maior valor da temperatura medida pelo sensor de temperatura do posicionador.· LOWEST TEMPERATURE: indica o menor valor da temperatura medida pelo sensor de temperatura do posicionador. TEMPERATURE: indica o valor da temperatura medida pelo sensor de temperatura do posicionador.

StatusStatus· BLOCK CONFIGURATION ERROR: indica erro nos componentes de hardware e software associados ao bloco.· LINK CONFIGURATION ERROR: indica erro na configuração do link.· SIMULATE ACTIVE: indica que o equipamento está no modo de simulação.· LOCAL OVERRIDE: indica que o equipamento está sendo operado manualmente.· DEVICE FAULT STATE SET: indica que o equipamento está em condição de falha• DEVICE NEEDS MAINTENANCE SOON: o diagnóstico interno da configuração do usuário ou a avaliação interna do equipamento detectou que o equipamento precisará de manutenção em breve.

Page 59: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Status (Cont...)Status (Cont...)· INPUT FAILURE/PROCESS VARIABLE HAS BAD STATUS: a condição da

variável de processo é BAD.· OUTPUT FAILURE: indica uma falha na saída que pode ter sido causada pelo

módulo eletrônico ou mecânico.· MEMORY FAILURE: indica uma falha eletrônica, dependendo do processo de

avaliação interna. Por exemplo, uma soma errada foi detectada na memória principal.

· LOST STATIC DATA: indica que o equipamento perdeu dados da memória flash ou EEPROM.

· LOST NV DATA: indica que o equipamento perdeu dados da memória RAM.· READ BACK CHECK FAILED: indica uma discrepância na leitura do valor de

retorno. Pode ter sido causada por uma falha de hardware.· DEVICE NEEDS MAINTENANCE NOW: o diagnóstico interno da configuração

do usuário ou a avaliação interna do equipamento detectou que o equipamento precisa de manutenção.

· POWER UP: indica que o equipamento finalizou o procedimento inicial de operação.

Page 60: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

• OUT-OF-SERVICE: indica que o bloco funcional está fora de serviço.• GENERAL ERROR: um erro ocorreu e não pode ser classificado como um dos erros

abaixo :

1. CALIBRATION ERROR: um erro ocorreu durante a calibração do equipamento ou um erro de calibração foi detectado durante a operação do equipamento.2. CONFIGURATION ERROR: um erro ocorreu durante a configuração do equipamento ou um erro de configuração foi detectado durante a operação do equipamento.3. ELECTRONIC FAILURE: um componente eletrônico falhou.4. MECHANICAL FAILURE: um componente mecânico falhou.5. I/O FAILURE: uma falha de E/S ocorreu.6. DATA INTEGRITY ERROR: indica que dados armazenados no sistema podem não ser mais válidos porque a somatória dos dados feito na memória RAM falhou ao ser comparada com os dados da memória não volátil.7. SOFTWARE ERROR: o software detectou um erro que pode ter sido causado por um desvio para uma rotina errada, uma interrupção, um ponteiro perdido, etc.8. ALGORITHM ERROR: o algorítmo usado no bloco transdutor gerou um erro. Por exemplo, pode ter sido causado por excesso de dados.

Page 61: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Advanced StatusAdvanced StatusIndica o estado do diagnóstico contínuo, incluindo as condições do módulo mecânico:

· REVERSAL LIMIT EXCEEDED: este alarme indica o limite de reversos configurado na página de configuração.

· TRAVEL LIMIT EXCEEDED: este alarme indica o limite do hodômetro configurado na página de configuração.· DEVIATION LIMIT EXCEEDED: este alarme indica o limite do desvio configurado na página de configuração.· MODULE PARAMETERS NOT INITIALIZED: alarme automático: parâmetros

do módulo mecânico não foram inicializados.· MODULE NOT CONNECTED TO THE CIRCUIT: alarme automático: módulo

mecânico não está conectado ao circuito eletrônico.· TEMPERATURE OUT OF RANGE: alarme automático: temperatura fora de

escala.· SLOW VALVE MOVEMENT OR LOW AIR SUPPLY: alarme automático:

movimento lento de válvula ou baixa pressão da fonte de ar.· MAGNET NOT DETECTED: alarme automático: o ímã não foi detectado.· BASE NOT TRIMMED: alarme automático: a base não está ajustada.

Page 62: CTS – © 1995 – 2005 SmarSystem302 SYSTEM302 ASSET VIEW SYSTEM302

CTS – © 1995 – 2005 Smar System302

Sensor PressureSensor Pressure

· SENSOR PRESSURE IN: indica a leitura do sensor de pressão da entrada.. SENSOR PRESSURE OUT1: indica a leitura do sensor de pressão da saída 1.. SENSOR PRESSURE OUT2: indica a leitura do sensor de pressão da saída 2.

Sensor Pressure StatusSensor Pressure Status

· SENSOR PRESSURE STATUS: indica o estado do sensor de pressão da entrada.