SUBMITTAL DATA SHEET
R-410A SPLIT SYSTEM CONDENSING UNITS
MODELS: 13 SEER18K TO 60K
JOB NAME: LOCATION:
PURCHASER: ORDER NO:
ENGINEER:
SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION:
SUBMITTED BY: DATE:
UNIT DESIGNATION: SCHEDULE NO. MODEL NO.
PRODUCT DATA
Cooling Performance
Total Capacity ________ MBH
Outdoor Design Temp_________ F
Electrical Data
Power Supply____/___/_____
Compressor Ampacity _______AMPs
Total Unit Ampacity ________AMPs
Power Input Req__________KW
Minimum Wire Size_________AWG
Overcurrent Device
Fuses Circuit BreakerUnit Weight
Unit Weight ________LBS
Heating & Air Conditioning
5
DIMENSIONAL DATA
AIR DISCHARGE: ALLOW 60
MINIMUM CLEARANCE.
"H" in. "W" in. "L" in. Liquid in. Vapor in.
18(cooling unit) 24-15/16 21-7/8 21-7/8 3/8 3/4
18(heat pump unit) 23-5/8 23-5/8 3/8 3/424 23-5/8 23-5/8 3/8 3/4
30 28 28 3/8 3/4
36 29-1/8 29-1/8 3/8 3/4
42 29-7/8 28 28 3/8 3/4
48 33-3/16 28 28 3/8 7/8
60 29-1/8 29-1/8 3/8 7/8
MODEL SIZEDimensions (Inches)
Refrigerant ConnectionService Valve Size
33-3/16
24-15/1624-15/16
24-15/16
24-15/16
VAPOR LINECONNECTION
CONTROL WIRING7/8 (22.2mm)
KNOCKOUT
1-11/32 (34.5mm)
LIQUID LINECONNECTION
DIMENSIONS
SERVICE
FITTING
SERVICE
FITTING
POWER WIRING
SEE DETAIL ADETAIL A
HOLE
1-3/32 (27.8mm)
SERVICE ACCESS
ALLOW 24 CLEARANCE
AIR INLETS
LOUVERED PANELS
ALLOW 18
MINIMUM
CLEARANCE
NOTE: GRILL APPEARANCE
MAY VARY.
W
-
7/29/2019 CSubmittal13SEERR410AFinal7-7-2011.pdf
2/2
Subject to change without notice.
Copyright2011 by Midea, Inc. All rights reserved.
FEATURES
CLEARANCES
MATCHING AIR SIDE EQUIPMENT
Model No. ________________
Submittal Form No. ________________
FIELD INSTALLED ACCESSORIES
Off Cycle Timer () ________________
Thermostats ________________
Blower Off Delay () ________________
Hard Start Kit ________________
Low Ambient Pressure Switch ________________
Service Access 18 Inches
All Other Sides 6 Inches
Above Unit 60 Inches
Below Unit 0 Inches
NOTES:
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
The compressor is protected against high/low pressure, tempera
-ture by a factory installed high/low pressure switch and a tempe
-rature sensor which protects the compressor if undesirable oper
-ating conditions occur.
A liquid line filterdrier is a optional part. We can also ship the unit
with the filterdrier per install.
The muffler can make the unit operation more quiet and stable
The low pressure inspect valve can make the installation easy
Accumulator can make the compressor free of liquid-slugged
Crankcase heater can protect the compressor when it stand by
Low ambient temperature protection (5)
High condenser coil temperature protection (127)
High quality heat-exchanger with inner-groove copper pipe and
aluminum fin
Anti-rust: painted galvanized steel cabinet, 500 hours salt spray
test
The operation ambient temperature rang is : AC 64-109;
HP 14-109;
Midea America Corp.