cryogenic economizers • ecl 502 series ecl502 series cryogenic economizers are designed to be used...

2
Application ECL502 series cryogenic economizers are designed to be used as pressure reducing valves to automatically maintain a constant inlet or back pressure, normally closed at pressures below its set point and open at pressures above its set point. The ECL502 is primarily designed to assist in maintaining a desired system pressure ideal for Nitrogen, Oxygen, Argon and other cryogenic cylinder applications with a 100% performance improvement over RegO’s ECLXXX series. ECL502 series offers outstanding performance for maintaining LNG fuel line pressure. Features ECL502 series design provides premium flow characteristics allowing for fast pressure reduction while maintaining sensitive flow control at lower pressure settings. All materials of construction- copper alloy, PTFE and stainless steel were selected for compatibility with cryogenic service. PTFE diaphragm liner vastly improves bubble-tight sealing performance for adherence to stringent external leakage requirements. 150 count mesh Monel screens installed into the inlet and outlet ports prevent debris from entering or damaging any downstream components. Interchangeable with existing cryogenic economizer units. Bi-directional flow for LNG fuel systems Temperature range: -320°F to +165°F (-196°C to +74°C) Max inlet pressure: Low Pressure Models ≤175: 375 PSIG (25.9 Bar) High Pressure Models >175: 550 PSIG (37.9 Bar) Pressure setting range: 10-350 PSIG (0.7-24 Bar) Clean for oxygen service per CGA G-4.1 Design in accordance with ECE R110 Materials Body ....................................................................................... Brass Spring Guide........................................................................... Brass Poppet Spring ........................................................... Stainless Steel Diaphragm Liner ..................................................................... PTFE Ball............................................................................ Stainless Steel Adjusting Screw........................................................ Stainless Steel Locknut ..................................................................... Stainless Steel Bonnet .................................................................................... Brass Screen .................................................................................... Monel Diaphragm ............................................................................ Bronze Slip Ring ................................................................................. Brass Diaphragm Plate ..................................................................... Brass Spring ....................................................................... Stainless Steel Spring Button ............................................................ Stainless Steel International, LLC Cryogenic Economizers • ECL 502 Series

Upload: nguyentruc

Post on 04-Apr-2018

220 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Cryogenic Economizers • ECL 502 Series ECL502 series cryogenic economizers are designed to be used as pressure reducing valves to automatically maintain a constant inlet or back

ApplicationECL502 series cryogenic economizers are designed to be used as pressure reducing valves to automatically maintain a constant inlet or back pressure, normally closed at pressures below its set point and open at pressures above its set point. The ECL502 is primarily designed to assist in maintaining a desired system pressure ideal for Nitrogen, Oxygen, Argon and other cryogenic cylinder applications with a 100% performance improvement over RegO’s ECLXXX series. ECL502 series offers outstanding performance for maintaining LNG fuel line pressure.

Features• ECL502 series design provides premium flow characteristics

allowing for fast pressure reduction while maintaining sensitive flow control at lower pressure settings.

• All materials of construction- copper alloy, PTFE and stainless steel were selected for compatibility with cryogenic service.

• PTFE diaphragm liner vastly improves bubble-tight sealing performance for adherence to stringent external leakage requirements.

• 150 count mesh Monel screens installed into the inlet and outlet ports prevent debris from entering or damaging any downstream components.

• Interchangeable with existing cryogenic economizer units. • Bi-directional flow for LNG fuel systems• Temperature range: -320°F to +165°F (-196°C to +74°C)• Max inlet pressure: Low Pressure Models ≤175: 375 PSIG (25.9 Bar) High Pressure Models >175: 550 PSIG (37.9 Bar)• Pressure setting range: 10-350 PSIG (0.7-24 Bar)• Clean for oxygen service per CGA G-4.1• Design in accordance with ECE R110

MaterialsBody ....................................................................................... BrassSpring Guide ........................................................................... BrassPoppet Spring ...........................................................Stainless SteelDiaphragm Liner ..................................................................... PTFEBall ............................................................................Stainless SteelAdjusting Screw ........................................................Stainless SteelLocknut .....................................................................Stainless SteelBonnet .................................................................................... BrassScreen ....................................................................................MonelDiaphragm ............................................................................ BronzeSlip Ring ................................................................................. BrassDiaphragm Plate ..................................................................... BrassSpring .......................................................................Stainless SteelSpring Button ............................................................Stainless Steel

International, LLC

Cryogenic Economizers • ECL 502 Series

Page 2: Cryogenic Economizers • ECL 502 Series ECL502 series cryogenic economizers are designed to be used as pressure reducing valves to automatically maintain a constant inlet or back

130.0

140.0

150.0

160.0

170.0

180.0

190.0

200.0

210.0

220.0

230.0

240.0

0 10 20 30 40 50 60 70 80

Tank

Hea

d P

ress

ure

(PS

I)

Elapsed Time (minutes)

Tank Pressure vs Time

ECL-140 Pressure (PSI) ECL502-140 Pressure (PSI)

TANK PRESSURE vs TIME

BACK OF PAGE

Cryogenic Economizers • ECL 502 Series

Old

NEW!

New ball poppet has approximately 300% increase in flow area of the old poppet.

C

B

D

AE

Part  NumberInlet/Outlet  Connec3ons  

AWidth  

BHeight  

CD E Pressure  Se@ng Opera3ng  Range

ECL502-­‐02222  psi                                                                        1.5  bar  

10-­‐60  psi0.7-4.1  bar

ECL502-­‐100100  psi                                                                    6.9  bar

ECL502-­‐123123  psi                                                                            8.5  bar  

ECL502-­‐140140  psi                                                              9.7  bar

ECL502-­‐175175  psi                                      12.1  bar

ECL502-­‐325325  psi22.4bar  

150-­‐350  psi                                              10.3-­‐24.1  bar

*Contact  sales  representa3ve  for  addi3onal  se@ngs.

1/4"  FNPT2.25"                                                                57  mm

3.5"                  89  mm

50-­‐175  psi                                                    3.4-­‐12.1  bar

0.58"        15  mm

1.0"25mm

ORDERING INFORMATION

International, LLC