RR-1RGR 4-1June 2015
2015 CEC Cryocooler Short Course
Copyright 2015 California Institute of Technology. Government sponsorship acknowledged. CL#15-2287
Cryocoolers for Space Applications #4
R.G. Ross, Jr.
Jet Propulsion LaboratoryCalifornia Institute of Technology
Topics
� Space Cryocooler Historical Overview andApplications
� Space Cryogenic Cooling System Design andSizing
� Space Cryocooler Performance and How It'sMeasured
� Cryocooler-Specific Application and IntegrationExample: The AIRS Instrument
![Page 2: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/2.jpg)
RR-2RGR 4-2June 2015
• Overview of AIRS Instrument
• Example Application Ground Rules and Requirements
• AIRS Cryosystem Conceptual Design
• Cryosystem layout and cryo loads estimation
• Important heatsinking considerations
• Sizing the Cryocooler for the Complete Mission Life Cycle
• BOL/EOL performance margin analysis
• Temperature Stability Requirements and Control
• Cryocooler Structural Integration Considerations
• Electrical Interface Considerations
• Meeting magnetic field requirements with shields
• Meeting Inrush and reflected ripple current requirements
Session 4: Detailed ExampleThe AIRS Instrument
Topics
![Page 3: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/3.jpg)
RR-3RGR 4-3June 2015
References
� Ross, R.G., Jr. and Green K., "AIRS Cryocooler SystemDesign and Development," Cryocoolers 9, PlenumPublishing Corp., New York, 1997, pp. 885-894.
� Ross, R.G., Jr., Johnson, D.L., Collins, S.A., Green K. andWickman, H. “AIRS PFM Pulse Tube Cooler System-levelPerformance,” Cryocoolers 10, Plenum, New York, 1999, pp.119-128.
� Ross, R.G., Jr., “AIRS Pulse Tube Cooler System LevelPerformance and In-Space Performance Comparison,”Cryocoolers 12, Kluwer Academic/Plenum Publishers, NewYork, 2003, pp. 747-754.
� Ross, R.G., Jr., “Cryocooler Load Increase due to ExternalContamination of Low-¶Ý Cryogenic Surfaces,” Cryocoolers12, Kluwer Academic/Plenum Publishers, New York , 2003,pp. 727-736.
![Page 4: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/4.jpg)
RR-4RGR 4-4June 2015
� Ross, R.G., Jr. and Rodriguez, J.I., “Performance of the AIRSPulse Tube Coolers and Instrument—A first Year in Space,”Adv. in Cryogenic Engin., Vol 49B, Amer. Inst. of Physics, NewYork, 2004, pp. 1293-1300.
� Ross, R.G., Jr., “Active Versus Standby Redundancy forImproved Cryocooler Reliability in Space,” Cryocoolers 13,Springer Science & Business Media, New York, 2005, pp. 609-618.
� Ross, R.G., Jr., et al., “AIRS Pulse Tube Coolers PerformanceUpdate – Twelve Years in Space,” Cryocoolers 18, ICC Press,Boulder, CO, 2014, pp. 87-95.
� See the AIRS instrument web site for up-to-date descriptionsof the science returns from the AIRS instrument and itsscience team members: http://www-airs.jpl.nasa.gov/
� http://www2.jpl.nasa.gov/adv_tech/ JPL website with 103 JPLcryocooler references as PDFs (R. Ross, webmaster)
References (Con't)
![Page 5: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/5.jpg)
RR-5RGR 4-5June 2015
AIRS (Atmospheric Infrared Sounder) is a NASA Earth Science Instrument
• AIRS is an Atmospheric Infrared Sounder
• Design: Highly stable IR spectrometerspanning visible to 15.4 ìm bands withFocal Plane cooled to 58¶K
• Launched: May 2002
• Still in orbit gathering data
• Science Output:
• Air Temperature Distributions
• Atm Gas Concentrations(CO, CO
2, CH
4, H
2O) over Planet
Water Vapor Transport
Launched on NASAAqua Spacecraft in
May 2002
![Page 6: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/6.jpg)
RR-6RGR 4-6June 2015
AIRSInstrument
EARTH SHIELD
150K
RADIATOR
190K
RADIATOR
OPTICAL
BENCH
HEAT REJECTION
COLD PLATES
AIRS Flight Instrument
The AIRS instrument wasdesigned and built underJPL contract by BAESystems, Lexington, MA
Atmospheric Infrared Sounder(AIRS) Instrument
![Page 7: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/7.jpg)
RR-7RGR 4-7June 2015
• Totally redundant cryocoolers—for enhanced reliability
• No heat switches—to avoid increased complexity, cost andunreliability
• Ambient heat rejection to spacecraft-supplied cold platesoperating between 10 and 25oC
• Cooler drive fixed at 44.625 Hz, synchronized to the instrumentelectronics
• Cold-end load (focalplane) mechanically mounted and alignedto the 150 K optical bench with a maximum vibration jitter onthe order of 1 �m
• Focalplane calibration (for temperature, motion, etc.) every 2.67sec (every Earth scan)
• Cooler input power goal of 100 watts (22 to 35 volts dc), andmass goal of 35 kg
• Cooler drive electronics fully isolated (dc-dc) from input powerbus; EMI consistent with MIL STD 461.
AIRS Cryosystem Ground Rulesand Requirements
![Page 8: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/8.jpg)
RR-8RGR 4-8June 2015
Detector Technologiesand Temperatures
INTEGRAL
AIRS
HST
SIRTF
Radiation Wavelength Blackbody Detector Detector Oper.Type (microns) Temp. (K) Technology Temp. (K)
â-rays 10-5 3 ´108 K Ge Diodes 80 K
â-rays 10-4 3 ´107 K Ge Diodes 80 K
x-rays 10-3 3 ´106 K micro 0.050 K
x-rays 10-2 3 ´105 K calorimeters 0.050 K
UV 0.1 30,000 K CCD/CMOS 200-300 K
visible 1 3000 K CCD/CMOS 200-300 K
IR 2 1500 K HgCdTe 55-130 K
IR 5 600 K HgCdTe 55-120 K
LWIR 10 300 K HgCdTe 35-80 K
LWIR 15 200 K HgCdTe 35-60 K
LWIR 20 150 K Si:As 6 -10 K
LWIR 50 60 K Ge:Ga 2.0 K
LWIR/ìwaves 100 30 K Ge:Ga 1.5 K
microwaves 200 15 K Bolometers 0.100 K
microwaves 500 6 K Bolometers 0.100¶K
![Page 9: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/9.jpg)
RR-9RGR 4-9June 2015
Operating Regions of Cryocoolersvs Detector Cooling Requirements
![Page 10: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/10.jpg)
RR-10RGR 4-10June 2015
Candidate Stirling CryocoolerRedundancy Approaches
AIRS
![Page 11: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/11.jpg)
RR-11RGR 4-11June 2015
AIRS Cryosystem Initial ConceptualDesign with Stirling Cryocoolers
COLDFINGER
BUMPERS
COUNTER
BALANCED
DISPLACER
Possible Issues
• Displacerheatsinking
• Displacervibration
• Displacerreliability
![Page 12: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/12.jpg)
RR-12RGR 4-12June 2015
Hughes CSE Cryocooler Mountedin Heat Sink Assemblies
![Page 13: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/13.jpg)
RR-13RGR 4-13June 2015
Incorporation ofInertance Tube
at TRW
Specific Power at 58 K
(TRW Coolers)
1W-35K
Rapid Development of the PulseTube Occurred Just in Time for AIRS
![Page 14: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/14.jpg)
RR-14RGR 4-14June 2015
EOL: 160K
Possible Issues
• OpticsContamination
• Pulse TubeContamination
• Horizontal PTs
• PT/OB relativemotion
BOL: 145K
AIRS Cryosystem Conceptual Designwith Pulse Tube Coolers
![Page 15: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/15.jpg)
RR-15RGR 4-15June 2015
Three Vacuum Level Issues: Gaseous Conduction, Cryopumpingloads, Increased Emittance from contaminant films
Typical Vacuum Levels Achieved:
10-8 torr: Exterior to spacecraft sunlit surfaces (short term)10-9 torr: Exterior to spacecraft sunlit surfaces (long term)
10-10 torr: Exterior to spacecraft shaded-side surfaces (long term)
Contamination Implications:
Vacuum Time for H2O Cryopumping
Level 1 ìm H2O Heat Transfer
10-6 torr 1.7 hours 340 mW/m2
10-8 torr 7 days 3.4 mW/m2
10-9 torr 70 days 0.34 mW/m2
10-10 torr 2 years 0.034 mW/m2
Vacuum Level Considerations forSpace Cryogenic Applications
![Page 16: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/16.jpg)
RR-16RGR 4-16June 2015
Space Vacuum
145K <10-8 torr
•
•
160K
145K
•
PulseTubes
Optical Bench BOL Design: 145 K (10-8.5 torr): Contamination Likely
Optical Bench EOL Design: 160 K (10-6 torr): Looks Good
Pulse Tube Design: 55 K (10-50 torr): Contamination Very Likely
AIRS Optical BenchContamination Risk Assessment
![Page 17: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/17.jpg)
RR-17RGR 4-17June 2015
Massive Heat Sinks Added toAIRS Pulse Tubes
![Page 18: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/18.jpg)
RR-18RGR 4-18June 2015
••
•
•
•
REGENERATOR
TEMPERATURE
COMPRESSOR
TEMPERATURE COLDPLATE
TEMPERATURE
ORIFICE
TEMPERATURE
Summary of AIRS Cooler SystemThermal Gradients
![Page 19: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/19.jpg)
RR-19RGR 4-19June 2015
AIRS Cryosystem Cold Link Designwith Pulse Tube Coolers
![Page 20: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/20.jpg)
RR-20RGR 4-20June 2015
AIRS Cold Link Assembly
Gold PlatedSapphire Rod
Copper Flex Braid
![Page 21: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/21.jpg)
RR-21RGR 4-21June 2015
AIRS Cold Link
Cryogenic Conductivity ofHigh Conductivity Materials
![Page 22: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/22.jpg)
RR-22RGR 4-22June 2015
Focal plane to Sapphire rod 1.57
Conduction down Sapphire rod 0.16
Sapphire rod to moly coupling 0.34
Resistance across shrink-fit joint 0.40
Resistance across flex braid 1.35
Coldblock contact resistance 0.30
Total focal plane/pulse tube thermal resistance 4.12
Resistance(K/W)ITEM
K/W
Breakdown of AIRS ColdlinkAssembly Thermal Resistances
![Page 23: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/23.jpg)
RR-23RGR 4-23June 2015
FOCAL PLANE: 58 K, OPTICAL BENCH: 145 K BOL, 160 K EOL
ITEMLoad (mW)
BOL EOL
Focal Plane Radiation Load from OB 73 108
Focal Plane Electrical Dissipation 193 193
Focal plane Lead Wire Conduction 98 118
Focal plane Structural Support Conduction 129 158
Radiation to Coldlink from Optical Bench 17 24
Radiation to Coldlink from Vacuum Housing 177 195
Off-state Conduction of Redundant Cryocooler 486 496
Total Cryocooler Load 1173 1292
Summary of AIRS InstrumentCryocooler Loads
![Page 24: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/24.jpg)
RR-24RGR 4-24June 2015
AIRS Predicted CryocoolerThermal Performance
![Page 25: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/25.jpg)
RR-25RGR 4-25June 2015
AIRS CryocoolerElectronics Efficiency
![Page 26: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/26.jpg)
RR-26RGR 4-26June 2015
AIRS BOL/EOL PerformanceMargin Analysis
BOL 200 mW 15oC Cooler EOL PARAMETER Unit Perfor- Load Heatsink Wearout Perfor-
mance Increase Increase Degrad. mance
Focalplane Temperature K 58 58 58 58 58Total Cooler Cold-End Load W 1.07 1.27 1.07 1.07 1.27Cooler Cold-tip �T to FP (3 K/W) K 3 3.4 3 3 3.4Cooler Cold-tip Temperature (T
C) K 55 54.6 55 55 54.6
Heat Rejection Coldplate Temp K 290 290 305 290 305Expander to Coldplate �T (0.16 K/W) K 9.8 11.2 10.6 12.0 16.8Comp. to Coldplate �T (0.05 K/W) K 3.0 3.5 3.3 3.8 5.3Avg. Cooler Rejection Temp (T
R) K 296 297 312 298 316
TC Correction for T
R� 300K (0.17 K/K) K +0.7 +0.5 -2.0 +0.3 -2.7
TC Correction for Cooler Wearout K 0 0 0 -5.0 -5.0
Total Cold-tip Temp Correction K +0.7 +0.5 -2.0 -4.7 -7.7Effective 300K Cold-tip Temp (T
EC) K 55.7 55.1 53.0 50.3 46.9
Cooler Specific Power at TEC
W/W 57 55 62 72 83Cooler Compressor Power (P) W 57 67 65 75 101Total Input Power (P/0.9 + 10) W 73 84 82 93 122Compressor Stroke % 64 68 67 70 80
![Page 27: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/27.jpg)
RR-27RGR 4-27June 2015
BOL
�EOL
1.271.07
�
AIRS BOL/EOL Operating StateVerification Analysis
![Page 28: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/28.jpg)
RR-28RGR 4-28June 2015
• Meet inrush and reflected ripple current requirements
� Accommodate broad input voltage ranges as compounded byhigh ripple current of cooler
� Suppress EMI to low levels consistent with MIL-Std 461 andaccommodate MIL-Std 461 susceptibility levels
� Provide high isolation from ground loops: case isolated fromground; possible dc-dc isolation from power bus
� Provide digital data interface for communication of commandsand transmission of measured parameters & performance data
Key Cryocooler ElectricalIntegration Considerations
![Page 29: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/29.jpg)
RR-29RGR 4-29June 2015
28V Bus
CoolerElect.Ripple
Filter
AIRS Cryocooler ElectronicsConducted Ripple Current
![Page 30: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/30.jpg)
RR-30RGR 4-30June 2015
Prototype Magnetic Shields Usedin Magnetic Shielding Studies
![Page 31: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/31.jpg)
RR-31RGR 4-31June 2015
AIRS Compressor AC Magnetic Fields(With and Without Mag Shields)
AIRS coolers withmag shields
![Page 32: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/32.jpg)
RR-32RGR 4-32June 2015
AIRS FlightInstrument
Launched on NASAAqua Spacecraft in
May 2002
TRW (NGAS)AIRS
PT Coolers
AIRS Flight Pulse Tube Coolers
![Page 33: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/33.jpg)
RR-33RGR 4-33June 2015
Cooler Drive LevelDuring First 50 Days of Mission
![Page 34: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/34.jpg)
RR-34RGR 4-34June 2015
Cooler Drive LevelDuring First 120 Days of Mission
![Page 35: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/35.jpg)
RR-35RGR 4-35June 2015
•
•
Cooler Load Pointfor 2-Cooler vs 1+Standby Operation
Operating Pointwith one-cooleroperation
Operating Pointwith two-cooleroperation
![Page 36: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/36.jpg)
RR-36RGR 4-36June 2015
Cooler Drive Level Summaryfor 12 Years of Operation
Cryocooler drive level has remainedrelatively constant over past 12 years
![Page 37: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/37.jpg)
RR-37RGR 4-37June 2015
•Operating Pointwith one-coolerin operation
A
B
%DRIVE
= BOL Operating Points with two-coolers in operation
= 12-year Operating Points with two-coolers in operation
AIRS Cooler Load PointSince Two-Cooler Operation Began
![Page 38: Cryocoolers for Space Applications #4€¦ · x-rays 10-2 3 ´105 K calorimeters 0.050 K UV 0.1 30,000 K CCD/CMOS 200-300 K visible 1 3000 K CCD/CMOS 200-300 K IR 2 1500 K HgCdTe](https://reader034.vdocuments.us/reader034/viewer/2022042211/5eb1767b43ed331ca8486beb/html5/thumbnails/38.jpg)
RR-38RGR 4-38June 2015
• AIRS was the first space instrument to commit to a pulse tubecryocooler and served as a very successful example
• Cooler performance characterization
• Dealing with Heat Rejection and Coldlink design
• Achieving tolerable generated vibration and EMI levels
• During the 20 years since the AIRS conceptual design wasdeveloped, we've learned a great deal more about a number ofintegration challenges:
• Two-cooler operational redundancy trade-offs
• Space vacuum levels and contamination sensitivity
• Cryo MLI performance
• Internal ripple current suppression
• Lighter and more efficient 2-stage coolers that can accommodateboth the 150K optical bench load and the 58 K focal plane load
• Bottom Line: Space cryocoolers continue to evolve and wecontinue to learn how to improve their system performance
Summary