cross reference ra part number: 194l-e32-1753 a · 2019. 8. 15. · product details and...

8
Product Details and Certifications Cross Reference RA Part Number: 194L-E32-1753 A Product: 194L-E32-1753 Description: 194L IEC Control and Load Switch, OFF-ON 90°, 32 Amp, 3 Poles, Front / Door Representative Photo Only (actual product may vary based on configuration sections) SWITCH DATA Bulletin 194E/L Control and Load Switches Enclosure Type Open Configuration OFF-ON 90° Size 32 A No. of Poles 3 Poles Installation Front / Door ACTUADOR Actuador Selection Select actuator separately CERTIFICATIONS AND APPROVALS UL CSA IEC CE For UL Certifications Directory: http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm

Upload: others

Post on 29-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cross Reference RA Part Number: 194L-E32-1753 A · 2019. 8. 15. · Product Details and Certifications Cross Reference RA Part Number: 194L-E32-1753 A Product: 194L-E32-1753 Description:

Product Details and Certifications

Cross Reference RA Part Number: 194L-E32-1753 A

Product: 194L-E32-1753Description: 194L IEC Control and Load Switch, OFF-ON 90°, 32 Amp,

3 Poles, Front / Door

Representative Photo Only (actual product may vary based on configuration sections)

SWITCH DATA

Bulletin 194E/L Control and Load Switches

Enclosure Type Open

Configuration OFF-ON 90°

Size 32 A

No. of Poles 3 Poles

Installation Front / Door

ACTUADOR

Actuador Selection Select actuator separately

CERTIFICATIONS AND APPROVALS

UL

CSA

IEC

CE

For UL Certifications Directory: http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm

JLNERI
Highlight
JLNERI
Red_Pointed_Right
Page 2: Cross Reference RA Part Number: 194L-E32-1753 A · 2019. 8. 15. · Product Details and Certifications Cross Reference RA Part Number: 194L-E32-1753 A Product: 194L-E32-1753 Description:

2 Rockwell Automation Publication 194-TD002B-EN-P

194 Control and Load Switches Product Overview

Bulletin 194E Bulletin 194L

Product Type Inductive load-rated load switch Inductive load-rated control/load switch

Current Range 16…100 A 12…40 A

Main Applications UL, CSA ratings "suitable as at-motor disconnect" UL, CSA ratings "suitable as at-motor disconnect"

Functionality� 3- or 6-pole switch configurations for OFF-ON or changeover

applications (16…100 A switches)

� 1- to 6-pole multifunction switch control configurations forOFF-ON, changeover, Star-Delta (Wye-Delta), reversing,ammeter, voltmeter, and step switch applications

� Also available in custom control configurations up to 16circuits for any unique control switching application.

Mounting Styles Front/door or base/DIN Rail mounting Front/door or base/DIN Rail mounting

Handles

� Handle colors in grey/black and red/yellow and padlockableversions

� Legend plates available in 0-I international markings and textstyles

� Uniformly styled handles: selector knob, disk style,rectangular style, and key-operated versions (Type 1/12, IP66)

� Handle colors in grey/black and red/yellow and padlockableversions

� Legend plates available in 0-I international markings and textstyles

Open Switch or Enclosed� Open switch (large frame Bul. 194E — open style only)� Enclosed: IP66 thermoplastic enclosure or UL/CSA rated

enclosureOpen switch

UL/CSA Electrical Ratings:Rated Voltage Ue 600V AC 600V AC

Rated Current Ie 16…100 A @ 600V 12…40 A @ 600V

Rated Power Pe [FLA] Varies w/ 1- or 3-phase switch, voltage Varies w/ 1- or 3-phase switch, voltage

Short-Circuit Ratings 5 kA 5 kA

Switching Rate [ops/h] 120 120

Mechanical Life [ops] 0.2 million (16…100 A switches) 1 million

IEC Rated Current Ie

AC-1 16…100 A @ 600V 12…40 A @ 600V

AC-21A 16…100 A @ 600V 12…40 A @ 600V

AC-22A 16…100 A @ 600V 12…40 A @ 600V

Ambient Operational Temp. -25…+60 °C (-13…+140 °F) -25…+60 °C (-13…+140 °F)

Ambient Enclosed Temp. -20…+60 °C (-4…+140 °F) -20…+60 °C (-4…+140 °F)

Ambient Storage Temp. -40…+80 °C (-40…+176 °F) -40…+80 °C (-40…+176 °F)

Protection class per IEC529 Switch bodies: IP2 Switch bodies: IP2

Optional Accessories� IP66 handles� Multi-length shafts and shaft extension kits� Terminal covers

� Multi-length shafts and shaft extension kits� Terminal covers

Standards/Certifications

� UL 508� CSA C22.2, No. 14� IEC 60947-3 Low Voltage Switchgear and Controlgear part 3� CE

� UL 508� CSA C22.2, No. 14� IEC 60947-3 Low Voltage Switchgear and Controlgear part 3� CE

JLNERI
Highlight
JLNERI
Red_Pointed_Down
Page 3: Cross Reference RA Part Number: 194L-E32-1753 A · 2019. 8. 15. · Product Details and Certifications Cross Reference RA Part Number: 194L-E32-1753 A Product: 194L-E32-1753 Description:

Bulletin 194L

IEC Control and Load Switches

2-435www.ab.com/catalogs Preferred availability cat. nos. are bbold.

Publication A117-CA001A-EN-P

0

1

2

3

4

5

6

7

8

9

10

11

12

13

Product Selection/Catalog Number Explanation

aInstallation Type

Code Description

A Base/DIN Mounting

E Front/Door Mounting

C Front/Door Mounting (For use with 32 A and 40 A switches only. Usewhen selecting 22.5 mm hole-mounting style handle.)

bLoad Size

Code Description Code Description

12 12 A 25 25 A

16 16 A 32 32 A

20 20 A 40 40 A

Bulletin 194L Control and Load Switches

Base/DIN Rail Mounting Front/Door Mounting Base/DIN Rail Mounting Front/Door Mounting Front/Door Mounting

12…25 A Base Mount 12…25 A Front Mount 32 A and 40 A Base Mount 32 A and 40 A Front Mount32 A and 40 A Front Mount,

for use with 22.5 mmmounting hole style handle

194L – A 16 – 175 3a b c d

cCode Function Configuration Use with Switch Style��: Circuit Diagram Ref. No.150

On/Off2-Position (60 degrees) 194L-E, 12…40 A, 1…6 poles 1501…1506

175 2-Position (90 degrees) 194L-E or 194L-A, 12…40 A, 1…6 poles 1751…1756178 2-Position (90 degrees-inverted) 194L-E or 194L-A, 12…40 A, 1…4 poles 1781…1784

225

Change-Over

1-2 (without 0, 45 degrees) 194L-E, 12…40 A, 1…5 poles or194L-A, 12…40 A, 1…2 poles 2251…2255

250 1-2 (without 0, 60 degrees) 194L-E, 12…40 A, 1…5 poles 2501…2505300 1-0-2 (with 0, 30 degrees, spring return) 194L-E, 12 A, 1…3 poles 3001…3003325 1-0-2 (with 0, 45 degrees) 194L-E or 194L-A, 12…40 A, 1…4 poles 3251…3254326 1-0-2 (with 0, 45 degrees, spring return) 194L-E, 12 A, 1…3 poles 3261…3263350 1-0-2 (with 0, 60 degrees)

194L-E, 12…40 A, 1…4 poles3501…3504

375 1-0-2 (with 0, 90 degrees) 3751…3754

425

Step Switch

1-2-3 (45 degrees) 194L-E or 194L-A, 12…40 A, 1 pole194L-E, 12…40 A, 2…3 poles 4251…4253

426 1-2-3-4 (45 degrees) 194L-E, 12…40 A, 1…3 poles194L-A, 12…40 A, 2 poles 4261…4263

427 1-2-3-4-5 (45 degrees)194L-E or 194L-A, 12…40 A, 1 pole

4271428 1-2-3-4-5-6 (45 degrees) 4281450 1-2-3 (60 degrees)

194L-E, 12…40 A, 1…3 poles4501…4503

451 1-2-3-4 (60 degrees) 4511…4513452 1-2-3-4-5 (60 degrees)

194L-E, 12…40 A, 1 pole4521

453 1-2-3-4-5-6 (60 degrees) 4531500 0-1-2-3-4 (30 degrees)

194L-E, 12…40 A, 1…3 poles5001…5003

501 0-1-2-3-4-5 (30 degrees) 5011…5013525 0-1-2 (45 degrees) 5251…5253526 0-1-2-3 (45 degrees)

194L-E or 194L-A, 12…40 A, 1 pole194L-E, 12…40 A, 2…3 poles

5261…5263527 0-1-2-3-4 (45 degrees) 5271…5273528 0-1-2-3-4-5 (45 degrees) 5281…5283550 0-1-2 (60 degrees)

194L-E, 12…40 A, 1…3 poles

5501…5503551 0-1-2-3 (60 degrees) 5511…5513552 0-1-2-3-4 (60 degrees) 5521…5523553 0-1-2-3-4-5 (60 degrees) 5531…5533725

Star-Delta(Wye-Delta)

0-Y-Δ (45/90 degrees)194L-E or 194L-A, 12…40 A, 3 poles

7253732 0-Y-Δ (45/90 degrees) 7323750 0-Y-Δ (60 degrees) 194L-E, 12…40 A, 3 poles 7503730

Reversing1-0-2 (45 degrees) 194L-E or 194L-A, 12…40 A, 3 poles 7303

754 1-0-2 (60 degrees) 194L-E, 12…40 A, 3 poles 7543825

Voltmeter0-RN-SN-TN-TR-ST-RS (45 degrees)

194L-E or 194L-A, 12 A, 1 pole

8251827 0-RS-ST-TR (45 degrees) 8271875

Ammeter0-1-2-3 (90 degrees) 8751

876 0-1-2-3-4 (90 degrees) 8761877 0-1 (90 degrees inverted) 8771

dNo. of Poles

Code Description

1 1 Pole

2 2 Poles

3 3 Poles

4 4 Poles

5 5 Poles

6 6 Poles

Catalog Number Explanation

� Not all possible configurations are available. Some configurations may have longer delivery times and minimum order quantities.�When choosing front mount style 194L-E for 32 A or 40 A, use the 194L-C code only if a 194L-HC style handle is being used.

JLNERI
Text Box
JLNERI
Typewritten Text
E32
JLNERI
Red_Pointed_Right
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Red_Pointed_Right
JLNERI
Red_Pointed_Right
JLNERI
Red_Pointed_Right
JLNERI
Red_Pointed_Right
Page 4: Cross Reference RA Part Number: 194L-E32-1753 A · 2019. 8. 15. · Product Details and Certifications Cross Reference RA Part Number: 194L-E32-1753 A Product: 194L-E32-1753 Description:

3Rockwell Automation Publication 194-TD002B-EN-P

Specifications 194E Load Switches

Electrical Ratings

Performance Data 16 A 25 A 32 A 40 A 63 A 80 A 100 A Aux.ContactsIEC Applications

Rated operational voltage (Ue): IEC� [V] 690 690 690 690 690 690 690 690

Rated operational voltage (Ue): UL, CSA [V] 600 600 600 600 600 600 600 600

Rated isolation voltage (Ui): IEC/UL, CSA [V] 690/600 690/600 690/600 690/600 690/600 690/600 690/600 690/600

Rated impulse voltage (Uimp): UL, CSA [kV] 8 8 8 8 8 8 8 8

Test voltage, (Ui) 1 minute [kV] 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5

Lost power per pole [W] 0.58 1.0 1.5 1.6 2.4 3.6 5.5 0.4

Rated frequency [Hz] 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60

Conventional free air thermal current Ith� [A] 25 40 50 63 75 100 120 12

Conventional enclosed thermal current Ie� [A] 20 32 40 50 63 80 100 10

Rated current Ie�

[A] 16 25 32 40 63 80 100 10AC-1/ Non-inductive or only slightly inductive

loads

AC-21A Switching of resistive loads with slightoverload

Rated power Pe

AC-23A Occasional switching of 3Ø motors and other highly inductive loads (criterion for selecting main switches)

230V [kW] 5.5 7.5 7.5 15 18.5 22 30 —

400V [kW] 7.5 11 15 22 30 37 55 —

690V [kW] 7.5 11 15 18.5 22 37 45 —

AC-3 Squirrel-cage motors; starting andstopping of running motors

230V [kW] 4 5.5 7.5 11 15 18.5 22 —

400V [kW] 5.5 7.5 11 15 18.5 30 37 —

690V [kW] 5.5 7.5 11 15 18.5 30 22 —

Short circuit current (co-ordination type 2)Rated conditional short-circuit current Maximum fuse rating of circuit (type g,G) Rated short-time current Icw (1 s)

400/415V

[kA] 20 20 15 20 15 30 25 —

[A] 20 25 35 50 63 80 100 —

[A] 800 900 900 1300 1300 2500 2500 —

Rated breaking capacity AC23A (cosφ 0.45)

230V [A] 156 296 296 484 484 780 780 —

400V [A] 120 256 256 504 504 800 800 —

690V [A] 70 136 136 196 196 376 376 —

DC switching capacity

1 poleRated current Ie

24/48V [A] 20 25 32 40 63 80 100

—110V [A] 5 5 6 8 10 16 20

220V [A] 1 1 1 1.5 15 3 3

440V [A] 0.5 0.5 0.5 0.6 0.6 0.7 0.7

DC-21A For resistive loads,T ≤ 1 msUe max = 660V

2 polesin

series

96V [A] 20 25 32 40 63 80 100

110V [A] 20 23 25 32 50 70 80

220V [A] 5 5 6 8 10 16 20

440V [A] 1 1 1 1.5 1.5 3 3

600V [A] 0.6 0.6 0.6 0.8 0.8 1 1

3 polesin

series

110V [A] 20 25 32 40 63 80 100

—220V [A] 13 13 15 20 28 50 63

440V [A] 2.2 2.2 2.2 3.6 3.6 6.5 6.5

600V [A] 1.3 1.5 1.5 2 2 3 3

Rated power Pe

3 polesin

series—

DC-23A, DC-3, DC-5 90V [kW] 1 1.3 1.5 2.9 4.1 5.1 7.2

For inductive loads,T ≤ 15 ms 110V [kW] 1 1.1 1.3 2.2 3.3 5.5 7

220V [kW] 0.8 0.9 1.1 1.7 2 3.5 4.4

440V [kW] 0.6 0.6 0.6 0.9 0.9 1.1 1.1

600V [kW] 0.4 0.4 0.4 0.5 0.5 0.9 0.9

�See standards compliance listed on http://ab.rockwellautomation.com/Circuit-and-Load-Protection/Disconnect-Switches/Non-Visible-Blade/194R-Fused-Non-Fused-Disconnect-Switches#specifications

JLNERI
Highlight
JLNERI
Highlight
JLNERI
Red_Pointed_Down
Page 5: Cross Reference RA Part Number: 194L-E32-1753 A · 2019. 8. 15. · Product Details and Certifications Cross Reference RA Part Number: 194L-E32-1753 A Product: 194L-E32-1753 Description:

4 Rockwell Automation Publication 194-TD002B-EN-P

194E Load Switches Specifications

Performance Data 16 A 25 A 32 A 40 A 63 A 80 A 100 A Aux.ContactsUL/CSA Applications

Continuous current [A] 16 25 32 40 63 80 100 —

Heavy Pilot Duty [AC] A600 A600 A600 — — — — A600

Standard Duty [DC] — — — — — — — Q600

Motor rating 60 Hz120V, 1P

[FLA] 16 16 16 24 34 56 80

—Single-phase (2poles)

[Hp] 1 1 1 2 3 5 7.5

240V, 1P[FLA] 12 12 17 17 28 50 68

[Hp] 2 2 3 3 5 10 15

480V, 1P[FLA] 8.5 8.5 14 21 26 34 68

[Hp] 3 3 5 7.5 10 15 30

600V, 1P[FLA] 11.2 11.2 11.2 16 20 27 44

[Hp] 5 5 5 7.5 10 15 25

Three-phase

120V, 3P[FLA] 13.6 13.6 19.2 30.4 40 56 84

[Hp] 2 2 3 5 7.5 10 15

240V, 3P[FLA] 9.6 15.2 22 28 42 68 80

[Hp] 3 5 7.5 10 15 25 30

480V, 3P[FLA] 11 14 21 27 34 52 65

[Hp] 7.5 10 15 20 25 40 50

600V, 3P[FLA] 11 11 17 22 27 52 52

[Hp] 10 10 15 20 25 50 50

Mechanical Data

Performance Data 16 A 25…32 A 40…63 A 80…100 AAux.

Contacts

Protection class according to IEC 529

Motor rating 60 Hz

handles IP66 IP66 IP66 IP66 IP66

switch bodies IP20 IP20 IP20 IP20 IP20

Mechanical life [million operations] 0.2 0.2 0.2 0.2 0.2

Max wire gauges

Terminal size per IEC 947-1 A4 A6 A7 A9 2xA2

rigid wire [AWG][mm2]

16…101…10

14…81.5…16

12…42.5…25

10…14…50

18…140.75…2.5

fine strands [AWG][mm2]

16…81.5…6

14…81.5…10

12…42.5…16

10…14…35

18…140.5…2.5

Tightening torque [N•m]/[lb•in] 1.4/12.2 1.4/12.2 2.8/24.5 5.6/50 1/8.8

Environmental Data

Storage -40…+80 °C (-40…+176 °F)

Operation -25…+60 °C (-13…+140 °F)

Electrical Ratings, Continued

JLNERI
Highlight
JLNERI
Highlight
JLNERI
Red_Pointed_Down
Page 6: Cross Reference RA Part Number: 194L-E32-1753 A · 2019. 8. 15. · Product Details and Certifications Cross Reference RA Part Number: 194L-E32-1753 A Product: 194L-E32-1753 Description:

17Rockwell Automation Publication 194-TD002B-EN-P

Specifications 194L Control and Load Switches

Performance Data 12 A 16 A 20 A 25 A 32 A 40 AIEC Applications

Rated voltage Ue � IEC-947 [V] 690 690 690 690 690 690

Isolating conditions acc. to VDE fulfilled up torated impulse voltage Uimp [kV] 6 6 6 6 8 8

Thermal rated current Ith� 40 °C IEC-947 [A] 16 20 25 30 32 45

Thermal rated current Ithe 60 °C IEC-947 [A] 12 16 20 25 32 45

Rated current Ie�

IEC-947 690V [A] 12 16 20 25 32 40AC-1/AC-21A

Non-inductive or slightlyinductive loads/switching of resistive loadswith slight overload

AC-1 Non-inductive or slightlyinductive loads SEV 660V [A] 12 16 20 25 32 40

AC22ASwitching of mixed resistiveand inductive loads with slightoverload

IEC-947 220…500V690V

[A][A]

1212

1616

2020

2525

3232

4040

AC-15Switching of inductive drives,motors, valves, andelectromagnets.

IEC-947220…240V380…415V

500V

[A][A][A]

532

64

2.5

753

864

— —

DC switching capacityRated current Ie

Contacts in series

Rated Voltage [V] 1 2 3 4 5 6 824 48 72 96 120 144 192 [A] 12 16 20 22 — —48 96 144 192 240 288 384 [A] 10 12 16 18 — —60 120 180 240 300 360 450 [A] 8 10 12 14 32 40

DC-21A For resistive loads, T ≤ 1ms 110 220 330 440 550 660 — [A] 2 2.5 4 5 — —

220 440 660 — — — — [A] 0.5 0.6 0.7 0.8 — —Ue max = 600V 440 — — — — — — [A] 0.4 0.4 0.5 0.5 — —

Rated making/breaking capacity (= 1.5 x Ie)

25.2 50.4 75.6 100.8 126 151.2 201.6 [A] 18 24 30 33 — —1.05 x Rated voltage [V] 50.4 100.8 151.2 201.6 252 302.4 403.2 [A] 15 21 24 27 — —

For resistive loads, T Ith 1ms 63 126 189 252 315 378 504 [A] 12 18 18 21 48 60

115.5 231 346.5 462 577.5 — — [A] 3 4.5 6 7.5 — —Ue max = 600V 231 462 — — — — — [A] 0.75 1.12 1.05 1.2 — —

462 — — — — — — [A] 0.52 0.78 0.47 0.75 — —Rated current Ie

Rated voltage [V] 24 48 72 96 120 144 192 [A] 8 10 12 14 16 1630 60 90 120 150 180 240 [A] 4.5 5.5 7 8 — —

For inductive loads T = 50 ms 48 96 144 192 240 288 384 [A] 1.5 2 2.5 3 8 8Rated voltage [V] 60 120 180 240 300 360 450 [A] 1 1.2 1.5 1.8 4.8 4.8

110 220 330 440 550 660 — [A] 0.4 0.5 0.6 0.7 2 2220 — — — — — — [A] — — — — 0.6 0.6

Rated making/breaking capacity (= 1.1 x Ie)

1.1 x Rated voltage [V] 26.4 52.8 79.2 105.6 132 158.4 184.8 [A] 8.8 11 13.2 1.54 — 17.633 66 99 132 165 198 231 [A] 4.95 6.05 7.7 8.8 — —

For inductive loads T = 50 ms 52.8 105.6 158.4 211.2 264 316.8 369.6 [A] 1.65 2.2 2.75 3.3 8.8 8.8

Ue max = 600V 66 132 198 264 330 396 462 [A] 1.1 1.32 1.65 1.98 5.28 5.28

121 242 363 484 605 — — [A] 4.95 6.05 7.7 8.8 2.2 2.2Power Lost [W] 0.3 0.5 0.6 0.9 0.8 1.4

Rated powerPe Contacts in series

Rated voltage [V]DC-23A, DC-3, DC-5For inductive loads, T ≤1 ms

24 1 [kW] 0.12 0.15 0.20 0.25 0.30 0.3024 2 [kW] 0.20 0.25 0.30 0.37 — —48 2 [kW] 0.25 0.30 0.37 0.50 0.50 0.5048 3 [kW] 0.30 0.37 0.50 0.75 — —60 2 [kW] 0.25 0.30 0.37 0.50 1.00 1.0060 4 [kW] 0.37 0.50 0.75 1.00 — —110 4 [kW] 0.50 0.75 1.00 1.20 — —110 6 [kW] 1.00 1.20 1.40 1.60 — —220 4 [kW] 0.37 0.50 0.75 1.00 — —220 6 [kW] 1.00 1.20 1.40 1.50 — —

�See standards compliance listed on http://ab.rockwellautomation.com/Circuit-and-Load-Protection/Disconnect-Switches/Non-Visible-Blade/194R-Fused-Non-Fused-Disconnect-Switches#specifications

Electrical Ratings

JLNERI
Highlight
JLNERI
Highlight
JLNERI
Red_Pointed_Down
Page 7: Cross Reference RA Part Number: 194L-E32-1753 A · 2019. 8. 15. · Product Details and Certifications Cross Reference RA Part Number: 194L-E32-1753 A Product: 194L-E32-1753 Description:

18 Rockwell Automation Publication 194-TD002B-EN-P

194L Control and Load Switches Specifications

Performance Data, Continued 12 A 16 A 20 A 25 A 32 A 40 A

IEC Applications, Continued

Rated making/breaking capacity (= 4 x Ie) Contacts in series

Rated Voltage [V] 25.225.250.450.46363115.5115.5231231

1223244646

[A][A][A][A][A][A][A][A][A][A]

20.033.321.025.016.624.618.136.46.7

18.1

25.041.625.030.820.033.327.243.69.1

21.8

33.350.030.842.024.650.036.451.013.625.2

41.661.641.662.433.266.444.058.218.227.2

50.0—

41.6—

66.6—————

50.0—

41.6—

66.6—————

DC-23A, DC-3, DC-5

For inductive loads, T ≤ 7.5 ms

Rated breaking capacity

at 220V0.45 [cos j]

at 380V0.45 [cos j]

at 660V0.45[cos j]

[A]

[A]

[A]

72

72

53

96

96

72

128

128

86

176

176

112

296

280

196

296

336

196

Rated power Pe� IEC-947

AC-2 Slip-ring motors: starting, reversing andelectric braking; star/delta starting

3-phase3-pole

240V380V415V440V500V660V

[kW][kW][kW][kW][kW][kW]

35.55.55.57.57.5

47.57.57.51010

5.5999

1111

5.51313131515

——————

——————

AC-3 Squirrel-cage motors: starting and stoppingof running motors

IEC-947

3-phase3-pole

220…240V380…440V

500V660V

[kW][kW][kW][kW]

2.24

5.55.5

35.57.57.5

4.57.5108

5.5111311

7.515—

18.5

7.518.5—

18.5

1-phase2-pole

110V220…240V380…440V

[kW][kW][kW]

0.751.32.2

1.12.23.7

1.22.54.5

1.63.25.5

—48

—416

AC-4 Squirrel-cage motors: starting, reversing,electric braking, inching

IEC-947

3-phase3-pole

220…240V380…415V440…550V

[kW][kW][kW]

0.751.51.5

1.52.22.2

33.73.7

45.55.5

5.57.57.5

5.57.511

1-phase2-pole

110V240V380V440V

[kW][kW][kW][kW]

0.180.370.750.75

0.370.751.11.1

0.551.51.81.8

0.752.233

————

————

�See standards compliance listed on http://ab.rockwellautomation.com/Circuit-and-Load-Protection/Disconnect-Switches/Non-Visible-Blade/194R-Fused-Non-Fused-Disconnect-Switches#specifications

JLNERI
Highlight
JLNERI
Highlight
JLNERI
Red_Pointed_Down_Right
Page 8: Cross Reference RA Part Number: 194L-E32-1753 A · 2019. 8. 15. · Product Details and Certifications Cross Reference RA Part Number: 194L-E32-1753 A Product: 194L-E32-1753 Description:

19Rockwell Automation Publication 194-TD002B-EN-P

Specifications 194L Control and Load Switches

Performance Data, Continued 12 A 16 A 20 A 25 A 32 A 40 A

IEC Applications, Continued

AC-23A

Occasional switching ofmotors and other highlyinductive loads(criterion for selecting mainswitches)

IEC-9473-phase3-pole

220…240V380…440V

500V660V

[kW][kW][kW][kW]

2.24

5.55.5

35.57.57.5

4.57.5108

5.5111311

1118.5—22

1122—22

1-phase2-pole

110V220…240V380…440V

[kW][kW][kW]

0.751.32.2

1.12.23.7

1.22.54.5

1.63.25.5

—5.511

—5.511

Short-circuit ratings

Rated short-time current(1s)Strongest series fuse, not inenclosureConditional rated short-circuit

(gL characteristic)

[kArms][A]

[kA]

0.4820�

6

0.4820�

6

0.620�

5

0.7525�

5

0.835

5

0.840

5

Switch Rate electrical [ops/h] 120 120 120 120 120 120

CSA and UL Applications

Rated Voltage Ue [V AC] 600 600 600 600 600 600

AmpereRating

Pilot DutyGeneral Use

Contact classNon-inductive or slightly inductive load‡ [A] A600

12A600

16—20

—25

—32

—40

Rated power Pe§ UL (CSA) (FLA) (FLA) (FLA) (FLA)

Standard motor DOL rating(similar to AC-3)

3-phase3-pole

120V240V480V600V

[Hp][Hp][Hp][Hp]

1 (7.2)2 (6.8)5 (7.6)5 (6.1)

1.5 (12)3 (9.6)

7.5 (11)7.5 (9)

2 (13.6)4 (12.4)8 (11.6)10 (11)

3 (19.2)6 (18)

12 (17)15 (17)

5 (30.4)7.5 (22)20 (27)20 (22)

5 (30.4)10 (28)25 (34)25 (27)

1-phase2-pole

120V240V480V600V

[Hp][Hp][Hp][Hp]

0.5 (9.8)1 (8.0)2 (6.0)3 (6.8)

.75 (13.8)1.5 (10.0)

3 (8.5)3 (6.8)

1 (16)2 (12)

4 (11.2)5 (11.2)

1.5 (20)3 (17)6 (17)

7.5 (16)

2 (24)5 (28)

7.5 (21)10 (20)

2 (24)5 (28)10 (26)15 (27)

Heavy motor load, reversing Rating (similarto AC-4)Max. back-up fuse

3-phase3-pole(gG characteristic)

120V240V

[Hp][Hp]

[A]

——35

——55

——60

——80

Short CircuitRatings

Maximum Short CircuitProspective Fault CurrentMaximum Fuse Size

[kA]

[A]

5

35

5

55

5

60

5

80

Switching Rate electrical [ops/h] 120 120 120 120 120 120

Mechanical Data

Performance Data 12/16 A 20/25 A 32/40 A

Protection class acc. to IEC 529 HandlesSwitch Bodies

IP66IP20

IP66IP20

IP66IP20

Mechanical Endurance [mil.ops] 1 1 1

Switching rate mechanical [ops/h] 1200 1200 1200

Maximum Wire Gauges

rigid wire

fine strands

AWG[mm2]AWG

[mm2]

(2)18…12(2)1…2.5(2)18…12(2)1…2.5

(2)16…10(2)1.5…6(2)16…10(2)1.5…4

(2)12…8(2)4…10

(2)14…10(2)2.5…6

Environmental Data

Performance Data 12/16/20/25 A 32/40 A

Ambient temperature

Operation -25…+60 °C(-13…+140 °F)

-25…+60 °C(-13…+140 °F)

Storage -40…+80 °C(-40…+176 °F)

-40…+80 °C(-40…+176 °F)

�Does not apply to switches in enclosure.‡ Suitable for switching off-load (AC-20) above 660V, but only up to 660V for switches with screws at the rear.§ See standards compliance listed on http://ab.rockwellautomation.com/Circuit-and-Load-Protection/Disconnect-Switches/Non-Visible-Blade/194R-Fused-Non-Fused-Disconnect-Switches#specifications

JLNERI
Highlight
JLNERI
Highlight
JLNERI
Red_Pointed_Down_Right