    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    Crimp Inspectionand

    Evaluation

  • 7/31/2019 Crimp Inspection & Evaluation

    2/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    CONTENTS

    1.Visual Inspection

    2.Insulation Crimp

    3.Conductor Crimp

  • 7/31/2019 Crimp Inspection & Evaluation

    3/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    Both the insulation & conductor are visible in theterminal inspection window

  • 7/31/2019 Crimp Inspection & Evaluation

    4/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    There Are No Wire Strands Nick.

  • 7/31/2019 Crimp Inspection & Evaluation

    5/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    The Insulation Has An Even Cut With No Tearing (Jagged Edges)

  • 7/31/2019 Crimp Inspection & Evaluation

    6/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    Bell Mouths On Conductor Crimp Meets Suppliers Specifications.

  • 7/31/2019 Crimp Inspection & Evaluation

    7/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    Wire Brush is Visible ,Uniform & Evenly Distributed.

  • 7/31/2019 Crimp Inspection & Evaluation

    8/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    Insulation Crimp Wings Contacts At Least 180 Degree Of TheInsulation Surface.

  • 7/31/2019 Crimp Inspection & Evaluation

    9/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    End Of Each Wing Contact The Wire Insulation.(Overlapping Crimp HasEnd Of One Wing In Contact With Insulation)

  • 7/31/2019 Crimp Inspection & Evaluation

    10/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    None Of The Wings Penetrate The Insulation.

  • 7/31/2019 Crimp Inspection & Evaluation

    11/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    Crimp Is Symmetrical.

  • 7/31/2019 Crimp Inspection & Evaluation

    12/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    No Insulation Extruded Between The Wing Gap.Wing Gap Is Not Greater Than 45 Degrees.

  • 7/31/2019 Crimp Inspection & Evaluation

    13/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    No Round Strand All Strands Are Deformed.Should Be Honey Comb Pattern

  • 7/31/2019 Crimp Inspection & Evaluation

    14/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    The Crimp Is Symmetrical The Distance Between The Wing Tips IsNot Greater Than The Material Thickness Of the Terminal.

    Strands Are Evenly Distributed.

    X= 0.25mm

  • 7/31/2019 Crimp Inspection & Evaluation

    15/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    No Air Gaps In The Conductor Crimps.

  • 7/31/2019 Crimp Inspection & Evaluation

    16/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    No Cracks Or Breaks In The Terminal Material Normally Linked ToExcessive Extrusion.

  • 7/31/2019 Crimp Inspection & Evaluation

    17/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    Wings Locked No Gap Between Wings.

  • 7/31/2019 Crimp Inspection & Evaluation

    18/18

    Koma x Automation India Pvt.Ltd.Professionals In Advanced Automation

    Wings Tips Do Not Contacts Bottom Or Side Of The Terminal.