NVLAP Lab Code 500089-0 Test Report Number: PL04859-001 RESTL-R010 Rev D This report contains data that are not covered by the NVLAP accreditation. Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Page 1 of 12 Report Number: PL04859-001 Model: STRLWY4MExx1F-ULA30K w/ STRLWY-BLS1 Date: 11/18/2014 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Leo Spychalla Cree, Inc. 9201 Washington Avenue Racine, WI 53406 Prepared By: Approved By: Linjie Li, Test Engineer Robert Higley, LC, Photometric Test Engineer

Upload: others

Post on 29-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    This report contains data that are not covered by the NVLAP accreditation.

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 1 of 12

    Report Number: PL04859-001

    Model: STRLWY4MExx1F-ULA30K w/ STRLWY-BLS1

    Date: 11/18/2014

    Cree Racine Engineering Services Testing Laboratory

    (RESTL) Photometric Testing and Evaluation

    Report

    Prepared For:

    Leo Spychalla

    Cree, Inc.

    9201 Washington Avenue

    Racine, WI 53406

    Prepared By: Approved By:

    Linjie Li, Test Engineer Robert Higley, LC, Photometric Test Engineer

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 2 of 12

    Product Information

    Manufacturer Cree, Inc.

    Model Number (SKU) STRLWY4MExx1F-ULA30K w/ STRLWY-BLS1

    Serial Number PL04859-001

    LED Type MDA

    Product Description

    Gray painted metal driver housing with one access door. Silver finned metal forward piece. Gray metal end cap. One PCB with ten LEDs. One white plastic optic carrier. One clear plastic optic below each LED. One black plastic backlight shield behind each optic.

    Driver Information (Where Applicable)

    Philips Advance LEDINTA1050C140DO

    Length Width Height

    23.0” 10.0” 4.0”

    Sample

    The following sample was submitted for evaluation

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 3 of 12

    Key Photometric Data Sphere Output Goniophotometer

    Luminous Flux 7307.9 7394.6 lm

    Efficacy 55.06 55.84 lm/W

    Correlated Color Temperature (CCT) 2937 K

    Color Rendering Index (CRI) 80

    R9 4

    Duv -0.00050242

    S/P Ratio* 1.25

    Sphere Goniophotometer

    Electrical Measurements 120V 277V 120V 277V

    Input Wattage 132.72 130.49 132.42 130.17 W

    Input Current 1.11 0.49 1.10 0.49 A

    Input Voltage 119.94 277.11 120.02 276.96 V

    Power Factor 0.998 0.961 0.999 0.964

    Off-State Power 0 0 0 0 W

    Total Harmonic Distortion (Voltage) 0.05 0.05 0.09 0.09 %

    Total Harmonic Distortion (Amperage) 3.96 7.68 4.16 8.01 %

    Note: All photometric measurements taken at 120VAC.

    Luminous Intensity Distribution Goniophotometer

    Max Candela 5169.9 Cd

    Angle of Max Candela (Horizontal) 45 ˚

    Angle of Max Candela (Vertical) 65 ˚

    Key Test Parameters Sphere Output Goniophotometer

    Stabilization Time 72 64 min

    Total Operating Time (Stabilization + Test) 77 84 min

    Ambient Temperature 24.0 25.2 ˚C

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 4 of 12

    Chromaticity Coordinates **

    x y u v u’ v’ Duv

    0.4407 0.4041 0.2530 0.3480 0.2530 0.5220 -0.00050242

    Color Rendering Index Details **

    Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14

    80 78 87 94 78 77 83 83 59 4 70 76 65 80 97

    Chromaticity Diagram **

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 5 of 12

    Spectral Distribution **

    λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm

    360 0.000536 530 0.076206 700 0.026066

    370 0.000378 540 0.085102 710 0.019461

    380 0.000092 550 0.094384 720 0.014574

    390 0.000152 560 0.105246 730 0.010762

    400 0.000118 570 0.118017 740 0.007891

    410 0.002346 580 0.130958 750 0.005854

    420 0.010038 590 0.141879 760 0.004268

    430 0.026302 600 0.147355 770 0.003218

    440 0.053502 610 0.146104 780 0.002347

    450 0.068159 620 0.138020 790 0.001685

    460 0.038703 630 0.124745 800 0.001253

    470 0.023455 640 0.108317 810 0.000913

    480 0.019308 650 0.090853 820 0.000556

    490 0.024763 660 0.074048 830 0.000407

    500 0.037904 670 0.058258

    510 0.052903 680 0.045273

    520 0.066051 690 0.034521

    Dominant Wavelength ** 583 nm

    Peak Wavelength ** 604 nm

    Spectral Power Distribution (W/nm) **

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 6 of 12

    Zonal Lumen Summary

    Zone Lumens % of Total Zone Lumens % of Total

    0-5 35.9 0.5% 90-95 0.0 0.0%

    5-10 107.3 1.5% 95-100 0.0 0.0%

    10-15 166.4 2.3% 100-105 0.0 0.0%

    15-20 200.8 2.7% 105-110 0.0 0.0%

    20-25 244.5 3.3% 110-115 0.0 0.0%

    25-30 307.9 4.2% 115-120 0.0 0.0%

    30-35 376.1 5.1% 120-125 0.0 0.0%

    35-40 447.1 6.0% 125-130 0.0 0.0%

    40-45 552.6 7.5% 130-135 0.0 0.0%

    45-50 729.6 9.9% 135-140 0.0 0.0%

    50-55 894.6 12.1% 140-145 0.0 0.0%

    55-60 907.8 12.3% 145-150 0.0 0.0%

    60-65 863.4 11.7% 150-155 0.0 0.0%

    65-70 768.6 10.4% 155-160 0.0 0.0%

    70-75 479.5 6.5% 160-165 0.0 0.0%

    75-80 217.2 2.9% 165-170 0.0 0.0%

    80-85 75.2 1.0% 170-175 0.0 0.0%

    85-90 20.1 0.3% 175-180 0.0 0.0%

    Total 7394.6 lm 100%

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 7 of 12

    Candela Plot Illuminance Plot

    Roadway Utilization Roadway Summary Lumens % Lamp

    Cutoff Classification SEMICUTOFF

    Distribution TYPE IV, SHORT

    Downward Street Side 6,288.1 85%

    Downward House Side 1,106.0 15%

    Downward Total 7,394.1 100%

    Upward Street Side 0 0%

    Upward House Side 0 0%

    Upward Total 0 0%

    Total Lumens 7,394.1 100%

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 8 of 12

    Luminaire Classification System

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 9 of 12

    Candela Tabulations

    0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180

    0 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552 1552

    2.5 1628 1641 1637 1639 1628 1623 1609 1604 1600 1596 1594 1593 1592 1592 1588 1585 1578 1572 1563 1553 1531 1476 1410 1372 1354 1334 1332 1324 1324 1314

    5 1683 1694 1691 1692 1679 1667 1646 1637 1631 1625 1621 1617 1613 1608 1601 1594 1584 1574 1557 1540 1490 1371 1307 1297 1309 1313 1328 1330 1334 1333

    7.5 1704 1712 1710 1710 1700 1691 1669 1657 1649 1641 1634 1627 1620 1613 1601 1590 1575 1560 1536 1512 1428 1297 1268 1290 1319 1335 1360 1369 1374 1374

    10 1707 1713 1707 1711 1702 1700 1675 1661 1651 1642 1631 1621 1610 1600 1584 1569 1550 1532 1501 1470 1354 1248 1249 1282 1322 1346 1377 1387 1391 1386

    12.5 1706 1712 1710 1719 1705 1690 1658 1639 1628 1616 1605 1593 1580 1566 1549 1532 1511 1489 1454 1418 1285 1217 1231 1271 1313 1306 1186 1022 937 880

    15 1693 1699 1707 1732 1720 1683 1631 1603 1589 1575 1564 1553 1542 1530 1514 1497 1473 1449 1409 1369 1236 1196 1218 1257 1244 915 598 467 427 410

    17.5 1644 1649 1676 1741 1746 1696 1614 1577 1562 1546 1537 1528 1516 1504 1488 1472 1447 1422 1377 1332 1203 1176 1202 1225 858 475 377 359 354 351

    20 1587 1598 1646 1777 1795 1717 1613 1573 1558 1542 1533 1525 1513 1500 1483 1466 1440 1414 1364 1313 1192 1160 1180 1012 476 357 343 336 333 330

    22.5 1577 1603 1711 1907 1896 1759 1637 1596 1581 1566 1556 1547 1532 1517 1498 1478 1449 1420 1365 1310 1198 1154 1153 673 361 331 321 314 312 309

    25 1675 1720 1855 2084 2071 1851 1683 1631 1614 1596 1586 1577 1558 1539 1516 1493 1462 1431 1375 1319 1216 1157 1086 436 328 310 300 296 294 292

    27.5 1825 1855 2024 2272 2249 2020 1742 1670 1650 1629 1617 1604 1581 1558 1532 1506 1474 1442 1389 1336 1242 1168 911 355 308 289 283 280 278 276

    30 1934 1966 2151 2401 2437 2194 1815 1703 1679 1655 1641 1626 1602 1578 1551 1525 1494 1463 1411 1360 1277 1186 700 319 287 272 268 264 263 261

    32.5 2035 2060 2250 2462 2579 2363 1894 1735 1709 1682 1668 1653 1630 1607 1582 1556 1526 1496 1448 1400 1326 1210 513 295 267 257 252 248 247 246

    35 2081 2113 2301 2513 2697 2508 1951 1773 1747 1722 1707 1692 1674 1655 1632 1610 1580 1550 1506 1462 1392 1238 403 273 250 242 237 231 230 228

    37.5 2152 2184 2303 2501 2777 2661 2014 1840 1812 1784 1770 1757 1743 1728 1709 1690 1665 1640 1608 1576 1515 1267 349 251 233 227 219 210 206 203

    40 2186 2232 2312 2493 2853 2763 2131 1953 1927 1900 1890 1879 1873 1867 1855 1843 1829 1815 1798 1780 1725 1285 315 231 220 213 198 184 171 165

    42.5 2230 2297 2362 2505 2898 2900 2342 2166 2146 2127 2125 2124 2130 2136 2146 2155 2170 2186 2188 2190 2139 1343 281 213 206 195 174 151 130 125

    45 2377 2457 2463 2560 3067 3200 2669 2549 2545 2541 2552 2564 2581 2598 2623 2648 2668 2687 2682 2676 2594 1343 244 196 190 176 151 122 101 98

    47.5 2634 2707 2674 2738 3344 3595 3007 2958 2969 2980 2989 2998 3014 3030 3063 3095 3109 3124 3104 3084 2948 1232 210 181 173 154 128 96 73 67

    50 2867 2914 2910 2857 3624 4020 3256 3341 3417 3492 3521 3550 3576 3602 3636 3670 3673 3675 3616 3558 3315 1135 184 166 155 132 108 74 46 38

    52.5 3022 3022 3047 2830 3685 4463 3481 3751 3909 4066 4069 4071 4033 3995 3976 3958 3919 3880 3769 3658 3340 969 164 151 137 114 91 57 30 26

    55 3108 3064 3040 2697 3528 4824 3733 3990 4130 4270 4203 4135 4039 3943 3903 3864 3791 3718 3570 3422 3047 689 147 139 121 98 76 44 25 24

    57.5 3014 2956 2910 2535 3308 4924 3702 3736 3910 4085 4034 3982 3895 3807 3767 3727 3630 3534 3354 3175 2734 467 137 130 107 85 63 37 24 23

    60 2570 2726 2771 2539 3232 4758 3320 3312 3585 3858 3863 3867 3760 3652 3559 3466 3323 3179 2970 2762 2306 330 134 124 95 74 52 32 23 22

    62.5 2363 2596 3108 2988 3406 4775 2896 2835 3161 3487 3493 3498 3368 3238 3103 2968 2798 2628 2418 2207 1778 244 135 120 87 66 44 28 22 22

    65 2690 3072 3842 3560 3677 5170 2751 2390 2610 2829 2940 3052 2935 2818 2676 2535 2352 2169 1960 1752 1369 196 136 114 80 58 37 25 22 22

    67.5 1998 2198 3730 3513 3723 4848 2373 1951 2028 2104 2305 2506 2363 2221 2070 1920 1748 1577 1407 1236 945 169 132 104 74 50 31 23 22 22

    70 1464 1446 3243 3085 3328 3971 1837 1469 1446 1423 1575 1728 1605 1483 1387 1291 1179 1067 942 818 511 142 124 95 67 42 27 22 21 21

    72.5 940 911 2229 2359 2550 3266 1392 1105 1026 948 1085 1222 1159 1096 1020 945 856 767 670 573 290 118 114 88 59 36 25 21 19 19

    75 602 567 1184 1675 1782 2644 1035 790 729 667 770 872 797 722 642 562 493 424 366 309 170 95 100 80 51 28 22 18 16 15

    77.5 362 344 503 965 1145 1877 744 572 517 462 466 470 407 344 294 244 212 180 160 139 98 70 87 70 43 22 19 14 12 11

    80 192 214 153 532 605 1154 442 378 312 245 215 185 156 126 112 97 89 81 76 71 61 56 74 61 34 18 15 12 9 8

    82.5 61 67 76 345 389 753 231 196 151 107 94 80 74 68 63 58 55 52 49 47 43 44 59 48 25 15 10 8 7 6

    85 8 10 27 177 217 534 127 78 61 44 42 40 39 37 35 32 31 30 28 26 25 32 42 30 15 11 6 4 4 4

    87.5 5 5 16 76 116 263 31 21 19 17 16 15 15 15 13 12 11 10 10 9 10 16 23 17 11 7 3 2 1 0

    90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 10 of 12

    Candela Tabulations (Continued)

    0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180

    92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 11 of 12

    Integrating Sphere Equipment List

    Description Manufacturer Model Serial Number

    2M Sphere Everfine 2M 1004156T

    CCD Array Spectrometer Labsphere MC-9801 98010360

    Programmable AC Source Adaptive FC200 2280220

    Power Analyzer Yokogawa WT310 C2QC04045V

    Goniophotometer Equipment List

    Description Manufacturer Model Serial Number

    AC Power Source Chroma 61602 616020002300

    Type C Goniophotometer LSI / UL 6440T 6440PN2028

    Spectroradiometer Gooch & Housego 770VIS/NIR 12415212

    Power Meter Yokogawa WT210 91M945458

    Test Methods Used:

    Title Description

    ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment

    CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources

    CIE Pub. 15:2004 Colorimetry

    IES LM-58:1994 Spectroradiometric Measurements

    IES LM-65:2001 Single-Ended Compact Fluorescent Lamps – Life Test Performance

    IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products

    Reference Standard Used:

    Equipment Description

    2m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number F119

    Type C Goniophotometer and Spectrometer

    Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Numbers 13C069. 13C070, 13C071. For color calibration of spectrometer, 13C074.

  • NVLAP Lab Code 500089-0

    Test Report Number: PL04859-001 RESTL-R010 Rev D

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 12 of 12

    Disclaimers:

    This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.

    The results contained in this report pertain only to the tested sample.

    This report shall not be reproduced, except in full, without written approval of the CESTL.

    Items marked with a single asterisk are not covered by the NVLAP accreditation.

    In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.

    ** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as

    “Sphere” or “Integrating Sphere”, were performed by the subcontracted laboratory identified in the footer on the

    first page of this report. Subcontracted testing is strictly integrating sphere based. All other tests are

    performed using a Type C goniophotometer.

    The integrating sphere information in the equipment list, report items marked with **, or results specifically

    identified as “Sphere” or “Integrating Sphere”, are the actual equipment used, and test results produced, by the

    subcontracted laboratory when subcontracting is indicated on the cover page.

    Additional Comments:

    The photos below are intended to show the orientation and fixturing/set-up of the units under test. These

    are critical to understanding the results of the test given the sensitivity of many products and

    measurement systems to orientation and set-up considerations, and also for reproducing the conditions of

    the test.

    Goniophotometer Integrating Sphere