corral column led [cctl/ccl] selux...cctl corral ® ® column led round tapered pole cccl corral...
TRANSCRIPT
Page 1 of 11 (Rev. 04/2021) CCCL_SS_1B.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2021, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
ApprovalsProduct Modifications Please list modification requirements for review by factory:
LED WARRANTY
5YEAR
Corral® Column LED
Project:
Type: Qty:
Date: Customer:
Date:
Series CCTLCorral® Column LEDRound Tapered Pole
CCCL Corral® Column LED Round 8” Straight Column
Height 101 10’
12 12’
14 14’
16 16’
1 Available with CCCL only
Light Engine 1B30 2B30 3B30 4B30
Nominal Height Lit Section
2 2’
3 3’
4 4’
CCT 27 2700K
30 3000K
353500K
40 4000K
FinishWH White
BKBlack
BL Semi-Matte Black
BZ Bronze
SV Silver
SP Specify Premium Color
Voltage UNV120-277V
120120V
240240V
277277V
3472,3
347V4802,3
480V 2 Requires step down transformer by Selux
3 Not available with HL50
OptionsDM Dimming (0-10V)
HL504Hi-Lo Switching Low output 50%
REC5,6GFCI Receptacle with weatherproof cover
REC25,6GFCI Receptacle with weatherproof padlockable in-use cover
REC35,6USB & DuplexReceptacle withweatherproofcover
REC45,6 USB & DuplexReceptacle withweatherproofpadlockablein-use cover
MS7Motion Sensor with Optional Photocell (Meets Title 24 requirements)
4 120V, 240V, and 277V only5120V only 6 See page 8 fo details7See page 4 for details
Order Code: - - - - - --
* See page 11 for details
* For other CCTs please consult factory.
* Custom colors available. Please consult factory.
BUY AMERICAN
Page 2 of 11 (Rev. 04/2021) CCCL_SS_1B.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2021, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Corral® Column LED
1. Luminaire Cover - Die-cast, aluminumcover, with smooth crisp form to reflect andcomplement the bollard design. Removes byloosening four stainless steel screws for easyaccess to LED chamber.
2. Gasketing - (not shown) Continuous gasketsprovide weather-proofing, dust, and insectcontrol at shielding base, and fixture cover.
3. Shielding - White, translucent, UV stabilizedacrylic, minimum wall thickness 0.118” (3mm)inside of die-cast aluminum “Corral” rings.
4. LED Light Engine - High efficiency LED lightengine equipped with brand-name LEDs,available in 2700K, 3000K, 3500K, or 4000K CCTtolerance within a 3-step MacAdam ellipse.90+ CRI standard.
5. Drivers - (not shown) Electronic universal120-277V, PFC > 0.95.
6. Column Fitter - Die-cast aluminum fitter,with built-in gasketing ridges, for smoothtransition to column.
7. Pole Fitter - Self-leveling, die-cast aluminum,fitter base secured to pole with two, stainlesssteel, allen head set screws. 3 1/2” (89mm) O.D.poles.
8. Surge Protector - (not shown) Designed toprotect luminaire from electrical surge (20kA).
9. Base Cover - (not shown, CCTL only)Standard two-piece base cover is made fromdie-cast 356 alloy aluminum which is heattreated to produce a T6 temper.
10. Hi-Lo Switching Option - (not shown)Please see page 8 for details.
11. Thermal Foldback - (not shown) IntegratedThermal Foldback circuit will reduce the drivecurrent if the ambient temper-ature exceedsthe maximum rated ambient temperature.This ensures maximum light output in various operating conditions while assur-ing long-term lumen maintenance.
Exterior Luminaire Finish - Selux utilizes a high quality Polyester Powder Coating. All Selux luminaires and poles are finished in our Tiger Drylac certified facility and undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultraviolet resistance for color retention. All products are tested in accordance with test specifications for coatings from ASTM and PCI.Standard exterior colors are White (WH), Black (BK), Semi-Matte Black (BL), Bronze (BZ), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide.
5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that the MTR Bollard LED luminaire shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED array when installed and operated according to Selux instructions. For details, see “Selux Terms and Condition of Sale.”
Listings and Ratings: Tested to INRTL Wet Location and IESNA LM-79-08 standards. LED tested to LM-80 standards. Luminaire and LED tested at 25°C (77°F) ambient temperature.
NRTL Listed for Wet Location (i.e. UL, CSA)
Visit selux.us for our LED End of Life recycling policy.
Specifications
8” (200mm)
Net Weight (4’ = 40lbs)
See
pag
e 5
1
4
3
6
Page 3 of 11 (Rev. 04/2021) CCCL_SS_1B.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2021, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Corral® Column LED
Type 09 (90º)
Sensor angular orientation from hand hole 0º90º increments clockwise around pole (Type 00, 09, 18, 27)
Factory Defaults:Delay to Dim: 5 minutes
Delay to Off: 1 hour
Sensitivity: Max
Custom Programming: Consult Factory
General column drawing for example only
Hand Hole Location
Type 00 (0º)
NominalColumnHeight
Type 18 (180º)
Type 27 (270º)
1’-6”(457.2mm)
Round Column Motion SensorThe Selux outdoor rated sensor incorporates Passive Infrared (PIR) Technology for motion sensing and also includes built-in photocell. Sensor comes pre-installed in cast aluminum housing painted to match column finish.
SeriesOptic
(270º coverage)Hand Hole
OrientationDim Level
Photocell Feature
Voltage
MSMotion Sensor
L (Low 8-12ft height)
M(Medium 13-20ft height)
00 0º Clockwise from
Hand Hole
09
90º Clockwise from Hand Hole
18 180º Clockwise
from Hand Hole
27*
270º Clockwise from Hand Hole
D0 (Off)
D1
(1V=10%)
D3 (3V=30%)
D5
(5V=50%)
Y Yes
N No
UNV (120-277V)
347* (347V)
480* (480V)
*consult factory for 347V and 480V
Top View
Page 4 of 11 (Rev. 04/2021) CCCL_SS_1B.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2021, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Corral® Column LED
General column drawing for example only
Motion Sensor Features• Customize programming using handheld wireless remote control
(FSIR-100) sold separately (by others)
• 5 Year Warranty
• 100% Digital PIR Detection, excellent RF Immunity
• 270° coverage pattern
• IP66 Rated for outdoor applications
• Made for LED light source
• Adjustable time delays, max/min dim levels, and ramp rates
• Suitable for Title 24 applications
(For coverage details refer to wattstopper FSP-211 spec sheet at www.wattstopper.com)
FSIR-100 (remote)
Sold Separately (by others)
Motion Sensor Option (MS) Wiring (120V-277V)
Wire Designation Table
Source Voltage (VAC) Wire Color Wire Designation
UNV(120V-277V)
Black L1
White Neutral (120V/277V or 208V/240V)
BLACK
WHITE
BARE
RED
ORANGE
L1
N /L2
DIM(+)
DIM(-)
BLAC
K
WHITE
GREE
N
BROW
N
VIOLE
T
GRAY
FromFeed Cord
SURGE PROTECTORMOTION SENSOR
Connection by others on site;motion sensor shipped separately.Cap dimming wires as shown.
LIGHTENGINE
Page 5 of 11 (Rev. 04/2021) CCCL_SS_1B.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2021, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Corral® Column LED
Mounting - CCTL
CCCL
3 1/2
" [88
.9mm
](T
YPIC
AL AL
L HEI
GHTS
)3 1
/2" [
88.9m
m]
(TYP
ICAL
ALL H
EIGH
TS)
3'-10
3/16
" [11
73.0m
m]
(4' LI
T SEC
TION)
2'-11
11/1
6" [9
06.0m
m]
(3' LI
T SEC
TION)
2'-1 3
/16"
[640
.0mm
](2'
LIT S
ECTIO
N)
3’-1
0 3/
16” (
1173
mm
) 4’
Lit
Sec
tio
n
Hei
gh
t (1
2’ N
om
ina
l Sh
own)
- s
ee c
ha
rt b
elow
fo
r a
ll h
eig
hts
Pole
hei
gh
t is
no
min
al
3 1/
2” (
89m
m)
(typ
ica
l all
hei
gh
ts)
4” x 7” (102mm x 178mm) Handhole provided with flush cover and stainless steel tamper-resistant hardware. (typical all heights)
Hei
gh
t (1
2’ N
om
ina
l Sh
own)
- s
ee c
ha
rt b
elow
fo
r a
ll h
eig
hts
Pole
Hei
gh
t is
No
min
al
Hei
gh
t (1
2’ N
om
ina
l Sh
own)
- s
ee c
ha
rt b
elow
fo
r a
ll h
eig
hts
Pole
Hei
gh
t is
No
min
al
Overall Height Nominal
Lit Section Nominal
Pole Height Nominal
Total Column Weight (lb)
AASHTO 1994 Max EPA Wind Rating
AASHTO 2001 Max EPA Wind Rating
AASHTO 2009 Max EPA Wind Rating
10’ (9’ - 10 1/16”) 4’ (3’ - 8 3/16”) 6’ (6’ - 1 13/16”) 62 (28 kg) 200mph 200mph 200mph
10’ (9’ - 10 1/4”) 3’ (2’ - 9 7/8”) 7’ (7’ - 0 5/16”) 53 (24 kg) 200mph 200mph 200mph
10’ (10’ - 0 7/8”) 2’ (1’ - 11 1/16”) 8’ (8’ - 1 13/16”) 51 (23 kg) 200mph 200mph 200mph
12’ (11’ - 10 1/16”) 4’ (3’ - 8 3/16”) 8’ (8’ - 1 13/16”) 69 (31 kg) 200mph 200mph 200mph
12’ (11’ - 10 1/4”) 3’ (2’ - 9 7/8”) 9’ (9’ - 0 5/16”) 60 (27 kg) 200mph 200mph 200mph
12’ (12’ - 0 7/8”) 2’ (1’ - 11 1/16”) 10’ (10’ - 1 13/16”) 58 (26 kg) 200mph 200mph 200mph
14’ (13’ - 10 1/16”) 4’ (3’ - 8 3/16”) 10’ (10’ - 1 13/16”) 76 (34 kg) 200mph 200mph 200mph
14’ (13’ - 10 1/4”) 3’ (2’ - 9 7/8”) 11’ (11’ - 0 5/16”) 66 (30 kg) 200mph 200mph 200mph
14’ (14’ - 0 7/8”) 2’ (1’ - 11 1/16”) 12’ (12’ - 1 13/16”) 64 (29 kg) 200mph 200mph 200mph
16’ (15’ - 10 1/16”) 4’ (3’ - 8 3/16”) 12’ (12’ - 1 13/16”) 82 (37 kg) 200mph 200mph 200mph
16’ (15’ - 10 1/4”) 3’ (2’ - 9 7/8”) 13’ (13’ - 0 5/16”) 73 (33 kg) 200mph 200mph 200mph
16’ (15’ - 9 13/16”) 2’ (1’ - 11 1/16”) 14’ (13’ - 10 13/16”) 70 (32 kg) 200mph 200mph 200mph
*Minimum clearance required (for maintenance or future upgrades)
4’ head = 60” (1524mm) 3’ head = 48” (1219mm) 2’ head = 36” (914mm)
*consult factory for alternative recommendationsif access above fixture is not available
Ø8” (200mm) (typical all heights)
2’-1
1 11/
16”
(90
6m
m)
3’ L
it S
ecti
on
2’-1
3/16”
(64
0m
m)
2’ L
it S
ecti
on
3 1/
2” (
89m
m)
(typ
ica
l all
hei
gh
ts)
Page 6 of 11 (Rev. 04/2021) CCCL_SS_1B.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2021, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Corral® Column LED
Mounting Details
*Minimum clearance required (for maintenance or future upgrades)
4’ head = 60” (1524mm)3’ head = 48” (1219mm)2’ head = 36” (914mm)
Ø8” (200mm)Typical All Heights
Hei
gh
t (1
2’ N
om
ina
l Sh
own)
= S
ee C
ha
rt B
elow
fo
r A
ll H
eig
hts
Pole
Hei
gh
t is
No
min
al
3’-1
1 7/
8” (
1216
mm
)(4
’ Lit
Sec
tio
n)
Ø5” (127mm)Typical All Heights
3” x 5” (76mm x 127mm)Handhole with flush cover and stainless steel tamper-resistant hardware. (Typical All Heights)
Ø7” (78mm)Typical All Heights
8” Remote Driver Tenon
Single 4’ lit section (Fixture Head)Effective Projected Area = 3.5 ft.2 (0.325m2)
Weight of Luminaire = 38 lb (17.23 kg)
Single 3’ lit section (Fixture Head)Effective Projected Area = 2.7 ft.2 (0.250m2)
Weight of Luminaire = 26 lb (11.79 kg)
Single 2’ lit section (Fixture Head)Effective Projected Area = 1.8 ft.2 (0.167m2)
Weight of Luminaire = 20 lb (9.07 kg)
Pole
Hei
gh
t is
No
min
al
Pole
Hei
gh
t is
No
min
al
3’-1
3/8”
(94
9mm
)(3
’ Lit
Sec
tio
n)
2’-2
7/8”
(682
mm
)(2
’ Lit
Sect
ion)
Overall Height Nominal
Lit Section Nominal
Pole Height Nominal
ASSHTO 1994 Max EPA Wind Rating
ASSHTO 2001 Max EPA Wind Rating
ASSHTO 12009 Max EPA Wind Rating
12’ (12’ - 0”) 4’ (3’ - 11 7/8”) 8’ (7’ - 8 1/8”) 110mph 150mph 150mph
12’ (12’ - 0”) 2’ (2’ - 2 7/8”) 9’ (8’ - 2 5/8”) 110mph 150mph 150mph
12’ (12’ - 3”) 3’ (3’ - 1 3/8”) 10’ (9’ - 8 1/8”) 110mph 150mph 150mph
14’ (14’ - 0”) 2’ (2’ - 2 7/8”) 10’ (9’ - 8 1/8”) 110mph 150mph 150mph
14’ (14’ - 0”) 2’ (2’ - 2 7/8”) 11’ (10’ - 2 5/8”) 110mph 150mph 150mph
14’ (14’ - 3”) 4’ (3’ - 11 7/8”) 12’ (11’ - 8 1/8”) 110mph 150mph 150mph
16’ (16’ - 0”) 4’ (3’ - 11 7/8”) 12’ (11’ - 8 1/8”) 110mph 150mph 150mph
16’ (16’ - 0”) 4’ (3’ - 11 7/8”) 13’ (12’ - 2 5/8 ”) 110mph 150mph 150mph
16’ (16’ - 0”) 3’ (3’ - 1 3/8”) 14’ (13’ - 5 1/8”) 110mph 150mph 150mph
Hei
gh
t (1
2’ N
om
ina
l Sh
own)
= S
ee C
ha
rt B
elow
fo
r A
ll H
eig
hts
Hei
gh
t (1
2’ N
om
ina
l Sh
own)
= S
ee C
ha
rt B
elow
fo
r A
ll H
eig
hts
*consult factory for alternative recommendations if access above fixture is not available
Page 7 of 11 (Rev. 04/2021) CCCL_SS_1B.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2021, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Corral® Column LED
Ø12 7/16” (316mm)
Ø4 11/16" [Ø119mm]CONDUIT OPENING
Ø8 5/8" [Ø219mm]BOLT CIRCLE
HANDHOLE SIDE OF POLE.
9 5/8" [244mm]
6 1/8" [155mm]
3 1/4
" [8
2mm
]
1/2" [13mm]FOR LEVELING
3/4-10 UNC GALVANIZEDHEAVY HEX LEVELING NUT
CONCRETE
3/4" I.D. GALVANIZEDFLAT WASHER
3/4-10 UNC GALVANIZED HEAVY HEX NUT
3/4-10 UNC X 17" PARTIALLYGALVANIZED ANCHOR BOLT
CCTL Bolt CircleUse caution when setting anchor bolts. Bolts must be vertically straight and centered on dimensions shown. Bolt Circle scale 1/4” = 1’
CCTL Anchor Bolt Detail
�7 7/8" [�200.0mm] O.D.
Ø7 7/8" [200.0mm]
�5 3/16" [�132.0mm]BOLT CIRCLE
�3 3/8" [�86.0mm]CONDUIT OPENING
3 11/16" [93.3mm]
HANDHOLE SIDE OF POLE.
3/4-10 UNC GALVANIZED HEAVY HEX NUT
3/4" I.D. GALVANIZEDFLAT WASHER
3/4-10 UNC GALVANIZEDHEAVY HEX LEVELING NUT
CONCRETE
3/4-10 UNC X 17" PARTIALLYGALVANIZED ANCHOR BOLT
CONDUIT (BY OTHERS)
3" [76.2mm]
1/16" [1.6mm]
REF.
CCCL Bolt Circle CCCL Anchor Bolt Detail
BC3 Standard Base Cover (CCTL)Die-cast aluminum, two-piece field installable base cover.
5 3/16” (131mm)
Ø12 7/16” (316mm)
Ø5” (127mm)
9 5/8” (244mm)
6 1/8” (155mm)
Ø4 11/16” (Ø119mm)Conduit Opening
Handhole side of pole
Handhole side of pole
3/4”-10 UNC X 17” partially galvanized anchor bolt
3/4”-10 UNC galvanized heavyhex nut
3/4” I.D. UNC galvanized flat washer
3/4”-10 UNC galvanized heavy leveling hex nut
Concrete
3
1/4”
(8
2mm
)
1/2” (13mm) for leveling
3/4”-10 UNC X 17” partially galvanized anchor bolt
3/4”-10 UNC galvanized heavyhex nut
3/4” I.D. UNC galvanized flat washer
3/4”-10 UNC galvanized heavy leveling hex nut
Concrete
Conduit (by other)
Ø7 7/8” (Ø200mm) O.D.
Ø5 3/16” (Ø132mm) Bolt Circle
Ø3 3/8” (Ø86mm) Conduit Opening
3 11/16”
(93mm)3”
(76 mm)
Ø7 7/8” (Ø200mm) O.D.
Ø8 5/8” (Ø219mm)Bolt Circle
1/16” (1.6 mm Ref.)
Page 8 of 11 (Rev. 04/2021) CCCL_SS_1B.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2021, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Corral® Column LED
Optional Accessories
(REC) GFCI RECEPTACLE DETAIL (120V)
(REC2) PADLOCKABLE IN-USE GFCI RECEPTACLE DETAIL (120V)
5/8” (15mm)
2 3/4” (70mm)
Pole (Generic View)
Cover shown in the closed position
(REC) GFCI RECEPTACLE DETAIL (120V)
(REC2) PADLOCKABLE IN-USE GFCI RECEPTACLE DETAIL (120V)
3 9/16” (91mm)
Pole (Generic View)
Cover shown in the closed position
2 1/4” (58mm)
REC and REC3 REC2 and REC4
4 1/2” (114mm)
6 11/16” (170mm)
GFCI Receptacle (REC) - 120V 15A GFCI duplex receptacle with weatherproof, self-closing cover; located 36” (915mm) o.c. from base of pole, in-line with hand hole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel (120V only).
USB & Duplex Receptacle (REC3) (not shown) - 120V 20A duplex receptacle with USB combination ports. (1) type A and (1) type C high power 5A, 5V USB outlets. With weatherproof, self-closing cover; located 36” (915mm) o.c. from base of pole, in-line with hand hole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel.
REC3 does not incorporate GFCI (Ground Fault Circuit Interrupter) protection, and shall be powered by a GFCI protected branch circuit (by others).
GFCI Receptacle (REC2) - 120V 15A GFCI duplex receptacle with weatherproof, self-closing, padlockable in-use cover; located 36” (915mm) o.c. from base of pole, in-line with hand hole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel (120V only).
USB & Duplex Receptacle (REC4) (not shown) - 120V 20A duplex receptacle with USB combination ports. (1) type A and (1) type C high power 5A, 5V USB outlets. With weatherproof, self-closing padlockable in-use cover; located 36” (915mm) o.c. from base of pole, in-line with hand hole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel.
REC4 does not incorporate GFCI (Ground Fault Circuit Interrupter) protection, and shall be powered by a GFCI protected branch circuit (by others).
Page 9 of 11 (Rev. 04/2021) CCCL_SS_1B.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2021, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Corral® Column LED
Wiring
Standard Single Wiring For 120-277V
Hi-Lo Switching Option (HL) WiringFor 120-277V. When red is energized, light output will be at “Lo” level. Standard HL level: HL50 = low output, 50%. For other combinations, consult factory.
Surge Protector
L1
N White
Black
Green
Ground
Light Engine
From Line Cord
Surge Protector
L1
N White
Black
Green
Ground
Light Engine
From Line Cord
RedL2
Relay
Page 10 of 11 (Rev. 04/2021) CCCL_SS_1B.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2021, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Corral® Column LED
Wiring
0-10V Dimming Option (DM) Wiring For 120-277V
Surge Protector
L1
N White
Black
Green
Ground
Light Engine
From Line Cord
Dim (-)
Dim (+)
Orange
Red
347/480V (Standard)
Surge Protector
L1
N White
Black
Green
Ground
Light EngineFrom
Line Cord
Auto Transformer
347/480V with 0-10V Dimming Option
Surge Protector
L1
N White
Black
Green
Ground
Light EngineFrom
Line Cord
RedDim (+)
Auto Transformer
OrangeDim (-)
Page 11 of 11 (Rev. 04/2021) CCCL_SS_1B.5
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2021, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Corral® Column LED
Photometry
CCCL / 16 FT / 4B30 / 3000K CCT
• Maximum candela of 913 at 90° from vertical.• IES classification - B2-U5-G3• Mounting Height = 16’ (4.87 M)• 6399 Delivered Lumens l 60 Lumens per Watt
CCCL / 16 FT / 1B30 / 3000K CCT
Catalog #: CCCL-X-4-1B30-30-UNV• Maximum candela of 552 at 90° from vertical.• IES classification - B0-U4-G2• Mounting Height = 16’ (4.87 M)• 1613 Delivered Lumens l 60 Lumens per Watt
CCT Multiplier
4000K 1.000
3500K 1.010
3000K 0.948
2700K 0.884 1B30 2B30 3B30 4B30
Hand hole
LED Lamping Distribution Guide
*Data based on 350mA LED driver current.
LED Information
Delivered Lumens (lm)
Wattage (W)
Efficacy (lm/W)