copy of omputer networking system for nccom 301111.xls
TRANSCRIPT
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
1/19
Sl.
No.
Description of Items Qty Unit Rate Amount
1 Providing following capacity 2800 - 2900 RPM single stage Centrifugalwater pump manufactured according to DIN/VDE/ISO 9001 standard
complete with steel base plate frame, coupling flange with gaskets, bolts,
nuts & standard, accessories etc. or closed coupled as required coupled
with 3-phase, 400 volt 5 %, 50 Hz 2900 RPM Horizontal motor having
six terminals for star-delta or DOL starting & totally enclosed fan cooled
& in built thermal protection etc. Made by CROMPTON
GREAVES/GEC / Pedrollo/SIEMENS/ or equivalent approved by theEngineeing-in-Charge.
5 H.P Tria bloc Pump Motor Set (KSB or equivalent approved by the
Engineeing-in-Charge.
Suction and delivery: 50 mm x 32 mm ( 2 " x 1.25" )
Discharge capacity :(5 -3 4) m/hr
Head: 40-22 meter 2 Set 118462 236924
2
Providing & fixing cast iron reflux vales(Non-Return valve) with cast iron
body, reflux valve cover plate, flap, valve disc & flap lined with leather,
cast iron hanging arm, stainless steel louver shaft & bolt with covergasket etc. including all other standard accessories (manufactured
according toDIN / ISO standard) as per sample approved by the
Engineer-in-charge. (MPL or equivalent approved by the Engineeing-in-
Charge.)Dia 50 mm (2) 1 No 3672 3672
3
Installation, Testing and Commissioning of the following capacity
Centrifugal water pump-motor Set on 304.8 mm (1') high (152.4 mm
below and 152.4 mm above floor level) C.C (1:2:4 ) base of required size
with 12.7 mm (") thick (1:4) cement plastering and neat cement finishing
over the exposed C.C surface, providing and fixing necessary bolts, nuts,
vibration isolator with making all electrical and pipe connection asrequired as per direction of the Engineer in charge.
Up to 7.5 HP. 2 Set 5265 10530
KvRi bvg: - b`wbs Ae evsjv`k wcRbm wWcvUgU _vcwKDigU Ae gWvb BKzBcgU UvcvU , KbvKkb AewijUW vKPvi cKi AvIZvq Kviv Awa`ii K`xq wWcvi,
Rjvi WcywU Rjvi WigUix I Kviv cwievi KjvY ms vi feb cvwb
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
2/19
4
Supply and installation of metal clad surface mounting type three phase
400 5% Volt 50 Hz. automatic direct-on -line (DOL) motor starter
complete with contractor, overload relay coil, etc. (Foreign made) of the
following range of rated current including supply of required fixing
materials as per direction of the Engineer in charge. (assembled by /
ADEX/SIEMENS/ SIGMA PUMP LTD or equivalent approved by the
Engineeing-in-Charge.)4 Amps to 17Amps (up to 5 H.P.) 2 Nos 7297 14594
5
Supplying, fitting and fixing G.I. pipe with all special fittings, such as bends,
elbows, sockets, reducing sockets, Tee, unions, jam-nuts etc. including cutting
trenches where necessary and fitting the same with earth duly rammed and
fixing in walls with holder bats and making hole in floors, walls and consequent
mending good the damages etc. all complete in all respects approved and
accepted by the Engineer.
50 mm dia G.I. Pipe with wall thickness 4.50 mm, outside diameter min
59.8 mm, weight 6.17 kg/m, can withstand min 50 kg/cm2 hydraulicpressure. 20 Mtrs 840 16800
32 mm dia G.I. Pipe with wall thickness 4.05 mm, outside diameter min
42.1 mm, weight 3.84 kg/m, can withstand min 50 kg/cm2
hydraulic
pressure. 5 Mtrs 513 2565
6
Supplying, fitting and fixing best quality G.I. gate valve with sealant etc.
complete approved and accepted by the Engineer.
32 mm brass gate valve 2 Nos 584 1168
7
Supplying, fitting and fixing best quality G.I. Check valve, threaded jointwith sealant etc. complete approved and accepted by the Engineer.
50 mm brass check valve 2 Nos 1331 2662
8
Providing & laying of the following PVC insulated & sheathed cable of
(NYY) with PVC insulated green/white coloured ECC wire (BYA
connecting at both ends, through PVC pipe & accessories in the following
manner:
In kutcha ground by cutting 45.70 cm width x 91.40 cm depth trench with
necessary brick or tile protection and mending the damages good by
refilling trench with proper compaction;
In pucca floor through PVC pipe by cutting trench of necessary size andmending the damages good by brick soling, 75 mm (1:2:4) CC work with
neat cement finishing etc.Cables manufactured by BRB/Paradise/Poly/ Supersign or equivalent
approved by the Engineering-in-Charge
1C-4 x 6 sq.mm (NYY) with 6 sq.mm (BYA) ECC wire through PVC pipe
of minimum inner dia 40 mm having wall thickness of 1.9 mm
In kutcha ground 65 626 40690
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
3/19
In pucca floor 12 708 8496
9 Providing & fixing on a prepared board 500 volt grade following Triple-pole moulded case Circuit Breaker (TPMCCB) with thermal over-current
and instantaneous electromagnetic short circuit release provision.Brand
and Country of origin of TPMCCB areABB (Italy), AEG (Germany),
DORMAN SMITH (England), LEGRAND (France/Italy), MEM (UK),
MERLIN GERIN (France), or equivalent approved by the Engineering-in-
Charge.32/40 Amps. (Minimum 10-KA) 3 Nos 7925 23775
10 Providing and fixing of pedestal type 18 SWG M.S. sheet steel board withproper reinforcement by M.S. flat bars, duly painted with two coats of
enamel paint over prime anticorrosive red oxide coat fitted on wall/floor
with necessary angle iron clamps/legs as per direction of the Engineer-in
charge. 1 Sq.M 3879 3879Total Taka 365755
Md. Karim uddin Shekar Chandra Biswas
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
4/19
Sl.
No.
Description of Items Qty Unit Rate Amount
1 Media Converter
Sub Head -A (Network Backbone Part)
Construction of National Crime Control & OperationMonitoring(NCCOM) Center
at Police Head Quarter Complex, Phulbaria, Dhaka. (Sub Head: Supply,
Installation, Testing & Commissioning of Computer Networking & Internet
System)
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
5/19
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
6/19
SWITCH (Core Switch)
Supply, Installation, Testing & Commissioning of Gigabit manageable
backbone/Core Switch with minimum 12-1000 Base-SX Port (Fiber)
and 12-1000Base-T Gigabit Ethernet Port with following Specification &
features as per direction of the Engineer -in -charge
Brand: CISCO or any internationally reputed brand
Model: (to be mentioned by Contractor)
Country of Origin: USA/UK/Japan/Korea or equivalent
Chassis Features:
Total Number of Slots : 3 (three)
Line Card Slots : 2 (two)
Engine Slots : 1 (one)
Number of Fan-Tray Bays : 1 (one)
Should have Redundant Power Supply
Line Card specification:
Minimum 6-Port 10/100/1000 PoE or SFP (Optional)
6 (six) 1000BASE-SX SFP module should be installed
Engine Performance and Switching Specifications :
Should have 12 10/100/1000 PoE and 8 SFP Ports on Engine
6 (six) 1000BASE-SX SFP module should be installed with the Engine
64-GBps switch fabric
48-mpps Layer 2 forwarding (hardware)
Layers 2 through 4 hardware-based switch
engine (application-specific integrated circuit [ASIC] based)
Centralized design
Unicast and multicast routing entries : 32,000
Layer 2 multicast addresses : 16,384
MAC addresses : 32,768
VLANs : 2048 active VLANs
Per-VLAN Spanning Tree (PVST+) and Per-VLAN Rapid Spanning
Tree Protocol (PVRST)
CPU (MHz) : 266 MHz
IP Forwarding Information Base (FIB) Entries : 32,000
Quality-of-Service (QoS) Sharing: Gigabit Ethernet only
Synchronous Dynamic RAM (SDRAM) : 256 MB
Onboard Flash Memory : 32 MB
Active Virtual LANs (VLANs) : 2000
Multicast Entries : 8000
Hardware-based routing at : 48mpps
Type of buffers : Dynamic
Spanning Tree Protocol Instances : 1500
Switched Virtual Interfaces (SVIs) : 1000
Internet Group Management
Protocol (IGMP) Snooping : Yes (16,000)
Security/QoS Hardware Entries : 32,000
Policers : 512 egress; 512
Jumbo Frames : up to 9216 bytes
Baby Giants : up to 1600 bytes
Engine should support below Layer 2 (two)Features:
2
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
7/19
Inter-Switch Link (ISL) VLAN encapsulation, Support for 2048 active
VLANs and 4096 VLAN IDs per switch, Ether Channel technology,
Fast Ether Channel, and Gigabit Ether Channel technology across line
cards, Port Aggregation Protocol,
Unidirectional link detection (UDLD) and aggressive UDLD, Q-in-Q
passthrough, Forced 10/100 auto negotiation, Web Content
Communication Protocol Version 2 Layer 2 Redirect, Private VLAN
(PVLAN) Promiscuous Trunk, Match class of service (CoS) for non-
IPv4 traffic, L2TP, CoS mutation.
Engine should support below layer 3 (three) features:
IGMP filtering on access and trunk ports, IP multicast routing protocols
(Protocol Independent Multicast [PIM], Source Specific Multicast
[SSM], Distance Vector Multicast Routing Protocol [DVMRP]), Group
Multicast Protocol server, Full Internet Control Message Protocol
(ICMP) support
ICMP Router Discovery Protocol, IPv6 software switches, EIGRP stub,
Virtual Router Redundancy Protocol (VRRP)
QoS and Traffic Management features:
Per-port QoS configuration, Support for four queues per port in
hardware, Strict priority queuing, IP differentiated service code point(DSCP) and IP Precedence, Classification and marking based on IP
type of service (ToS) or DSCP, Classification and marking based on full
Layer 3 and Layer 4 headers (IP only), Input and output policing based
on Layer 3 and Layer 4 headers (IP only), Support for 512 policers on
ingress and 512 policers on egress configured as aggregate or
individual, Shaping and sharing output queue management, Dynamic
Buffer Limiting (DBL): congestion-avoidance feature, No performance
penalty for granular QoS functions, Auto-QoS CLI for voice-over-IP
(VoIP) deployment, Per-port, per-VLAN QoS, Selective DBL
Predictable Performance
Layer 4 TCP/UDP hardware-based filtering at 48mpps
No performance penalty with advanced Layer 3 and Layer 4 services
enabled
Software-based learning at a sustained rate of 500 hosts per second
Support for 32,000 MAC addresses
Support for 32,000 entries in routing table, shared between unicast &
multicast
Bandwidth aggregation up to 16 Gbps through Gigabit Ether Channel
technoHardware-based multicast management
Hardware-based ACLs, router ACLs (RACLs) and VLAN ACLs
(VACLs)
Comprehensive Management features:
Manageable through Network Assistant
Single console port and single IP address to manage all system features
Software configuration management, including local and remote
storage
Simple Network Management Protocol (SNMP) Versions 1, 2, and 3
instrumentation, delivering comprehensive in-band management
CLI-based management console to provide detailed out-of-band
management
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
8/19
Remote Monitoring (RMON) software agent to support four RMON
groups (history, statistics, alarms, and events) for enhanced traffic
management, monitoring, and analysis
Support for all nine RMON groups through the use of a Switch Probe
analyzer (Switched Port Analyzer [SPAN]) port, which permits traffic
monitoring of a single port, a group of ports, or the entire switch from a
single network analyzer or RMON probe
Analysis support, including ingress port, egress port, and VLAN SPANLayer 2 traceroute, Remote SPAN (RSPAN), Smartports macros, SPAN
ACL filtering, SPAN CPU port, Dynamic Host Configuration Protocol
(DHCP) client auto configuration, Enhanced SNMP MIB support, Time
Domain Reflectometry (TDR), MAC Address Notification, Generic
Online Diagnostics (GOLD)
Advanced Network Security features:
TACACS+ and RADIUS, which help enable centralized control of the
switch and restrict unauthorized users from altering the configuration,
Standard and extended ACLs on all ports, 802.1x user authentication
(with VLAN assignment, voice VLAN, port security, guest VLAN,
private guest VLAN, PVLAN, and RADIUS-supplied session timeout
extensions), 802.1x accounting, 802.1x authentication failure, 802.1x
PVLAN assignment, 802.1x Private Guest VLAN, 802.1x RADIUS-
supplied time out, NAC Layer 2 802.1x, NAC Layer 2 IP, Trusted
boundary, RACLs on all ports (no performance penalty), VACLs, Port
ACLs (PACLs), PVLANs on access and trunk ports, DHCP snooping,
DHCP Option 82, DHCP Option 82 insertion, DHCP Option 82 Pass
Through, Port security, Sticky port security, Secure Shell (SSH) Protocol
Versions 1 and 2, VLAN , Management Policy Server (VMPS) client,
Unicast MAC filtering, Unicast port flood blocking, Dynamic Address
Resolution Protocol (ARP) inspection, IP Source Guard, Community
PVLANs, Trunk Port Security, 802.1x Inaccessible Authentication
Bypass, MAC Authentication Bypass Control Plane Policing, 802.1x
Unidirectional Controlled Port,
Voice VLAN Sticky Port Security Secure Copy Protocol (SCP), EtherChannel Trunk Port Security, IP Source Guard for Static Hosts, IEEE
802.1x Multi domain Authentication
High Availability features:
HSRP, VRRP
Regulatory Compliance: CE marking
Safety:
UL 60950, CAN/CSA-C22.2 No. 60950, EN 60950, IEC 60950, TS 001,
AS/NZS 3260
EMC: FCC Part 15 (CFR 47) Class A, ICES-003 Class A, CISPR22 Class
A, AS/NZS 3548 Class A, VCCI Class A, EN 55022, EN 55024, EN
61000-6-1, EN 50082-1, EN 61000-3-2, EN 61000-3-3, ETS 300 386
Warranty:
The Contractor shall provide warranty of the system for 1 (one) year
from the date of successful Commissioning ( manufacturer warranty
part number must be mentioned)1
No.(M/R)
1007802 1007802
SERVER
Supply, Installation, Testing & Commissioning of Server with following
Specification or equivalent as per direction of the Engineer-in-charge.
Brand: HP/ Dell/ IBM or any internationally reputed brand
Country of Origin: USA/UK/Japan/Korea or equivalent
3
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
9/19
Specification:
Processor : Quad-Core Intel XeonTM
Clock speed : 2.53 GHz
Chipset : Intel 5520 series or higher
QPI : 5.86 GT/s Quick Path Interconnect
No. of Processor : 1 (one), up-gradable up to 2 (two)
Cache Memory : Min. 8 MB L3 cache
Memory : Min. 8 GB (2x4GB or 4x2GB) DDR3
installed Upgradeable up to 144 GB (Min.18 DIMM Slots)
Hard Drive : Min. 4 (four) x 146 GB Hot Plug SAS (15K rpm)
Optical Drive : DVD +/- RW (factory fitted)
Storage type : Hot Plug 2.5-inch. SAS/ SATA
Drive bays : Min. 8, Hot Plug to support SAS & SATA drives
Expansion Slots : 3 (three) PCI Express
RAID Controller : RAID controller with 256 MB Battery backed
cache (supporting RAID level- 0,1,5,6 SAS/SATA)
Graphics : Integrated Video Controller with 16 MB Video
Memory
I/O Ports : Min. 4-USB 2.0 (2 up front), Serial, Video (15-pin),VGA, Keyboard
OS Support : Microsoft Windows 2003/2008 Server, Novell
Netware, LINUX (RedHat, SUSE)
System Management: System management software to be provided
with the server (should have the capacity to manage all servers from a
single console)
Security : Power-on password, Setup password, Diskette
boot control, Parallel and serial interface control, Disk
configuration lock, Power switch security
Power Supply : 230V AC Input Voltage, hot-plug, redundant
power w/ redundant hot plug cooling fanForm Factor : Rack-mount chassis with mounting kits
Warranty : 03(three) Years fully on-site from the date of
successful commissioning
Benchmarking : Performance test report must be attached by the
Contractor (of specific organisation or equivalent size & capacity of
Server). Mail/Database/Web/APP/DNS Server1
No.(M/R)
343128 343128
ROUTER
Supply, Installation, Testing & Commissioning of Modulator Router
with following Specification or equivalent features as per direction of
the Engineer- in- charge.
Brand: CISCO or any internationally reputed brand
System Features:
Should have Embedded hardware-based cryptography acceleration
(IPSec + SSL)
Total onboard WAN 10/100/1000 Ports: 03 (RJ-45-based)
Should have 2-Port Serial WAN Interface Card with V.35 compatible
cable
Service Module slots: 01
EHWIC slots: 04
Double-wide EHWIC slots: 02
ISM slots: 01
4
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
10/19
Onboard DSP (PVDM) slots: 02
Memory DDR2 ECC DRAM Default: 512 MB
Memory (DDR2 ECC DRAM) Maximum: 2 GB
Compact Flash (ext.) Default: Slot 0: 256 MB, Slot 1: none
Compact Flash (ext.) Maximum: Slot 0: 4 GB, Slot 1: 4 GB
Serial console port and Serial auxiliary port: 01
Router Switching Performance: 353,000 PPS & 180.73 Mbps
SIP Sessions: 200
IOS Should Support BGP, OSPF, EIGRP, IS-IS, RIP, PBR, IGMP, IOS
Firewall, SSL VPN, DMVPN, IPS, GET VPN, IP Sec.
Multicast forwarding, Protocol independent Multicast (PIM) (both
sparse and dense mode), (S,G), (*,G), Bidirectional PIM in hardware
Comprehensive MPLS supported
Group Management Protocol and Internet Group Management
Protocol (IGMP) snooping
Layer 3 routing protocols, Border Gateway Protocol version 4 (BGPv4),
Open Shortest Path First (OSPF), Intermediate System-to-Intermediate
System (IS-IS), Routing Information Protocol (RIP), Distributed FIB
Switching, Internet Control Message Protocol (ICMP)
Should provide advanced security services and management
capabilities such as built-in hardware encryption acceleration, IP
Security (IPSec), VPN (Advanced Encryption Standard [AES], Triple
Digital Encryption Standard [3DES], DES
IOS Firewall zoning
High speed WAN environments with concurrent services enabled up
to 75 Mbps multi-gigabit fabric enabled high-bandwidth module-to-
module communication without compromising routing performance
Energy-saving features
Powered by high-performance multi-core processors
Embedded hardware encryption acceleration
TDM interconnectivity fabric in the system architecture Supporteduniversal-serial-bus (USB)-based console access
Up-gradation option to internal power supply for 802.3af-compliant
PoE integrated switch modules
Single OS image encompassing all IOS technology features
Standards-certified Voice XML browser services
IPT (Supported):Future up-gradation possibility for IPphonecall
processing,Future up-gradation possibilityforbackup/fallbackIP
phonecallprocessing,up-gradationpossibility for voice
messagingand auto attendant, scalability for centralized and
distributed call processing
Protocol should support backup routes and unequal cost load
balancingSupport for Unified Wireless Architecture
Support for Third-generation (3G) wireless WAN modules
Environmental Specifications:
(i) Operating Conditions : Temperature: 32F to 104F (0C to
40C) Maximum altitude: 5,906 feet (1,800m), Altitude: 13,000 ft
(4,000m), Relative humidity: 5% to 85%;
(ii) Non-operating Conditions : Temperature: 40F to 176F (40C to
80C), Altitude: 15,000 ft (4,570m), Relative humidity: 5% to 95%
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
11/19
Safety Compliance: UL 60950-1, CAN/CSA C22.2 No. 60950-1, EN
60950-1, AS/NZS 60950-1, IEC 60950-1
Electromagnetic Compatibility (EMC): 47 CFR, Part 15, ICES-003
Class A, EN55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A,
VCCI V-3, CNS 13438, EN 300-386, EN 61000 (Immunity), EN 55024,
CISPR 24, EN50082-1
Power Specifications:
AC input voltage : 100 to 240 VAC auto rangingAC input frequency : 47 to 63 Hz
AC input current range AC power supply (max): 2.2 to 1.0A
AC input surge current :
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
12/19
7 DMZ Switch (Managable Switch)
8 Fiber Optic Cable
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
13/19
Total Taka 2999251
Md. Ayub Ali Shekhar Chandra Biswas
Sub-Assistant Engineer Sub-Divisional Engineer
PWD E/M Sub Division-8 PWD E/M Sub Division-8
Motijheel, Dhaka. Motijheel, Dhaka.
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
14/19
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
15/19
WIRELESS ACCESS POINT (WAP)3
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
16/19
Supply, Installation, Testing & Commissioning of wire less Access Point
with following Specification & features as per direction of the Engineer
in- charge.
Brand : CISCO or any internationally reputed brand
(to be mentioned by Contractor)
Model : (to be mentioned by Contractor)Country of Origin : USA/UK/Japan/Korea/ or Equivalent
Standalone 802.11a/g/n Wireless LAN Access Point supporting dual
frequency band, MAC filtering, web-based configuration, centralized
security management and having minimum 200m indoor coverage with
following features:
2x3 multiple-input multiple-output (MIMO) with 2 (two) spatial
Maximal ratio combining (MRC)
Legacy beam forming
20- and 40-MHz channels
PHY data rates up to 300 Mbps
Packet aggregation: A-MPDU (Tx/Rx), A-MSDU (Tx/Rx)
802.11 dynamic frequency selection (DFS) (Bin 5)
Cyclic shift diversity (CSD) support
Should have features like Radio resource management (RRM), Clean
Air technology etc.
Data Rates Supported:
802.11a: 6, 9, 12, 18,24, 36, 48, and 54 Mbps
802.11g: 1, 2, 5.5, 6,9, 11, 12, 18, 24, 36, 48, and 54 Mbps
Integrated Antenna:
2.4 GHz, Gain 4.0 dBi, horizontal beam width 360
5 GHz, Gain 3 dBi, horizontal beam width 360Interfaces:
10/100/1000BASE-Tautosensing (RJ-45)
Management console port (RJ45)
Environmental:
Non-operating (storage) temp : -22F to 185F (-30C to 85C)
Operating temperature : 32F to 104F (0C to 40C)
Operating humidity : 10% to 90% (non-condensing)
System Memory:
128 MB DRAM
32 MB flashSafety Standards:
UL 60950-1, CAN/CSA-C22.2 No 60950-1, UL 2043, IEC 60950-1, EN
60950-1
Security:
802.11i, Wi-Fi Protected Access 2 (WPA2), WPA
802.1 X
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
17/19
Advanced Encryption Standards (AES), Temporal Key Integrity
Protocol (TKIP)
Warranty:
The Contractor shall provide warranty of the system for 1 (one) year
from the date of successful Commissioning ( manufacturer warranty
part number must be mentioned)QTY = {GF-1, (FF- 4F)@ 3 Nos.( 5F-2Nos. & 6F- 1 No.}
16Nos.
(M/R)
47238 755
MDF / Network Rack with Patch Panel
Supply, Installation, Testing & Commissioning of MDF / Network Rack
with Patch Panel with following Specification as per direction of the
Engineer in charge.Brand : Any internationally reputed brand, (to be mentioned by bidder)
Specification:
Industry-made brand MDF (Main Distribution Facility) with Fiber
Patch Panel (24 Port Rack Mount loaded with SC Adapters) and GE
Patch Panel of appropriate type & size (accommodating switches,
routers, server farm/ DMZ switches, patch cord of appropriate type &size etc) including wire manager, necessary cable ties etc complete with
all required accessories and following features:
Rack Size : 42U
Cooling System : Min. 4 AC Cooling Fans
Front Door : Perforated Glass Removable Door with
Rear Door : 1 (one)
Ventilation : Superior Ventilation
Cable Run System : Separate Runways for Top & Bottom cable
runsVertical Cable Organizer : Yes, Min.8 Cable Rings
PDU/ Power Strip : Min.4 (four) Nos. Power Strip having Min.
6 (six) Outlets each (16 Amp.)
Power Distribution : Sub-distribution Board incl. Ground Bar
Post : Min.4 Nos. of Heavy Duty Feet/Wheels1
No.(M/R)
292287 292
Wiring with UTP Cat-6 Cable
Surface channel wiring with UTP Cat-6 Cable through 1mm thick PVC
channel complete with other accessories etc. as required including
mending the damages good as per sample approved by the Engineer-in
charge.
1000Mtrs
(M/R)114 114
UPS
Supply, Testing & Commissioning of 1000 VA uninterruptible power
supply (UPS) complete with central processing unit suitable for input
supply 160-275 volt AC single phase 50 Hz for output voltage 220 volt
5%, 50 Hz single phase having protection for lightening & surge, back-
Back-up time: 30 minutes at full load & 60 minutes at half load
(One for Core Switch & another for Server) 2Nos.(S/R)
20323 40
6
4
5
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
18/19
7 UPS
FACE PLATE(Cat-6 UTP )
Supply, Installation, Testing & Commissioning of FACE PLATE (Cat-6
UTP) with following Specification as per direction of the Engineer in
charge.
Specification:
Face Plate with MK Box (plastic type), dual module with cover and all
required accessories. (For Wireless Access Points)25
Nos.
(M/R)
650 16
PATCH CORD (Cat-6 UTP)Supply, Installation of PATCH CORD (Cat-6 UTP) with following
Specification as per direction of the Engineer- in- charge.
Brand: Digi-Link/ AMP/ Micronet/ Systimax/ Belkin or equivalent
Specification:
Industry-made brand 3 (three) meters Patch Cord of Cat-6 UTP cable
with RJ-45 connectors at both ends and all required accessories25
Nos.(M/R)
359 8
PATCH CORD (Multimiode FO)Supply, Installation of PATCH CORD (Cat-6 UTP) with following
Specification as per direction of the Engineer- in- charge.
Brand: Digi-Link/ AMP/ Micronet/ Systimax/ Belkin or equivalent
Specification:
Industry-made brand 3 (three) meters Patch Cord of Cat-6 UTP cable
with RJ-45 connectors at both ends and all required accessories
25 Nos.(M/R)
359 8
11 Fiber Optic SC Connector
12 Patch Panel(Fiber)
10
8
9
-
7/28/2019 Copy of omputer Networking System for NCCOM 301111.xls
19/19
13 Wireless Adaptor
14 Power Socket
15 Pwer Wiring
LAN INSTALLATION
Installation of LAN including replacement of the existing UTP
backbone with Fiber Optic backbone etc complete as per the guideline
provided in the TOR and as per direction& satisfaction of the Engineer-
in- charge.
1Job(M/R)
50000 50
Total Taka 3008
Md. Ayub Ali Shekhar Chandra Biswas
Sub-Assistant Engineer Sub-Divisional Engineer
PWD E/M Sub Division-8 PWD E/M Sub Division-8
Motijheel, Dhaka. Motijheel, Dhaka.
16