2013: Al Shaheen: Well-Test to Well-Stimulation

Our Conversion Operation for Al Mansoori

Page 2: Converting for Al Mansoori

Well-Test• Process of testing

planned data to maximise knowledge of oil and gas wells.

• Vessels for well-testing incorporate a processing plant; capturing oil and gas flared during testing operations

Originally designed by Henderson International in 2003 for Well-Testing; commissioned by Al Mansoori in 2004.

SHIP PARTICULARS

Length Overall 56 m

Length on Waterline 50.5 m

Breadth Moulded 13.6 m

Depth Moulded 6 m

Summer Draft 4.7 m

Trial Speed 12.5knot

s

Page 3: Converting for Al Mansoori

Well-Stimulation; The Conversion• Done to stimulate

existing wells increasing production and flow of hydrocarbons.

Conversion required; addition of 11.4 section parallel to the middle body. Along with 2x acid tanks.

New exhaust chimneys with mounting and securing stimulation equipment on-deck

MACHINERY

Main Engines 2 x 1440 kW

Main Generators 3 x 190 kW

Emergency DG 1 x 120

Main Propulsion System 2 x Schottel SRP

Bow Thruster 2 x 534 kW

Pump Jet 1 nos

Capstans 2 x Elec Driven Vertical HeadPull 10t/5t @ 10/20 m/min

Deck Crane 3t @ 25m radius25t @ 3m radius

Acid Tanks 2 x 30,000 USG

Page 4: Converting for Al Mansoori

What Was Done; Summary

• Ship was cut in the middle at 11.4.• 2x acid tanks added at midship• Alteration of air ventilation

• Re-design of piping

• Well-stimulation cabin added on upper forecastle deck

• Well-stimulation equipment installed, secured on deck• Exhaust chimney and air intake installed on deck.WHY? Vessel, initially was 60M; not meeting longitudinal length criteria.

Heavy weight of the midship, also warranted tank loading modifications; meeting strength criteria.

Ventilation, by IBC regulations was also modified for acid tanks