Page 1: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

CEILING DIFFUSERStechnical

types -CD, CAB

C O N T R O L T H E A I R Y O U B R E A T H E

Europair Africaa division of Performancair Products Africa (Pty) Ltd

Cnr. Grader and VuurslagSpartan Ext. 3

Kempton ParkJohannesburg

tel +27 11 974 2425fax +27 11 974 7251web www.europair-africa.comemail: [email protected]

Page 2: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

ADJUSTABLE BLADE CEILING DIFFUSER - CAB

FIXED BLADE CEILING DIFFUSER - CD

FEATURES

• All Aluminium construction offers exceptional quality and performance.

• Light in weight. yet strong and durable.• Wide range of sizes, both square and rect-

angular,• Other finishes available upon request.• Complete selection data to ensure quiet,

draft less air distribution.• Tested and rated in accordance with

specifications.

• Versatility is the key to why the popular directional or pattern-type diffusers are being used so widely for so many different applications.

• Recommended for heating, ventilation, and cooling, the directional type diffuser provides directed air diffusion, channelling the designed amount of conditioned air into the areas where it is needed.

• Available in a wide range of sizes, both square andrectangular.

• There's the choice of one, two, three, four way patterns segmented in rectangular, corner, "y" or diagonal configurations.

• This takes care of and permits changes as the use or arrangement of conditioned space is varied.

• The desired versatility is designed into the diffusers. Offered exclusively in extruded aluminium, the diffuser models provide the best robustness and durability combined with inflamibility in directed air diffusion.

• The core is easily removable for access to the duct.• The frame and core are constructed of 1.25mm

thickness extruded aluminium.• All models can be supplied with a surface finish off

temperature-set white powder coated paint preceded by a seven-stage preparation process of degreasing, acidbathing and passivation.

• This process ensures proper paint adhesion which provides long lasting aesthetics and durability.

• To enhance the appearance of the units, the finest available paints are used which can be matched to your colour requirements.

• Optional aluminium paint is available at no extra charge.• There are two frames available depending on the

application in use.• The flat frame is standard whilst a bevelled frame can be

supplied on request.

• Further versatility is added to the diffuser range by way of adjustable blades.

• A similar range of blow patterns as for fixed ceiling diffusers are available.

• Adjustable blades allows ultimate control in the direction of flows.

Details

CEILING DIFFUSERS 02

Page 3: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Pattern Requirement

TABLE 1 - Recommended NC Level Design Goals

AIR FLOW

NC LEVEL

• The performance data which follows permits quick, easy and accurate selection of diffusers.

• Two groups of data are required for selection.• The first group is that established by the structural

and room-use considerations.• The second group consists of the performance

characteristics of the diffusers.• Consider first the spaces which are to be condi-

tioned and their effects upon outlet selection.

• The pattern requirement is determined by the shape of the space to be conditioned, the number of diffusers in it, and the type and location of lighting fixtures or other devices mounted on the ceiling.

• For example a two-way opposite 2A, 2B or 2C - might be used in a corridor.

• A larger area can often be divided into squares or rectangles of nearly equal size and, if a diffuser can be located in the center of each of these areas, patterns 4A or 4B could be used for four-way delivery.

Throw Requirement

• The required throw is determined from the building plan after the diffuser location has been decided.

• The throw requirement is the distance from the diffuser to the nearest enclosing wall.

• In some cases the throw requirement will be the distance from the diffuser to the intersection of its air stream with air being delivered from another diffuser.

• For high ceiling applications, the throw require-ment may be measured as the horizontal distance described above plus the vertical distance from the diffuser to occupied zone.

• This is usually considered to extend to the 1,5m level in the room.

• Another consideration is diffuser mounting height.

• As air travels from a diffuser, room air is entrained into the supply air stream and the delivery pattern thickens. If the throw requirement is too great, the lower part of the supply air stream can intrude into the occupied zone of the conditioned space.

• To avoid this, diffusers should be located so that the throw requirement is no greater than 1.5 times the diffuser mounting height.

• For example, in a space with a 3.6m ceiling height diffusers should be so located and in such numbers that the required throw of any one diffuser Vi/auld not exceed 5.5m.

• The final consideration is the pressure loss of the diffuser.

• The performance data which follows permits quick, easy and accurate selection of diffusers.

• Two groups of data are required for selection.• The first group is that established by the structural

and room-use considerations.• The second group consists of the performance

characteristics of the diffusers.• Consider first the spaces which are to be condi-

tioned and their effects upon outlet selection.

• The permissible sound level in each space may be specified by the owner or the architect, or it may be determined as an engineering design goal. Table 1 contains an abbreviated list of design goals for air-conditioning sound control in common occupancies.

Details

CEILING DIFFUSERS 03

Page 4: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

TABLE 2 - Recommended Max Throw Requirement

TABLE 3 - Velocity Pressure

ADDITION TO OPEN DAMPER NC

TABLE 4 - NC ADDITION FOR DIRECTIONAL DIFFUSER WITH OBD.

• The basic selection data in Tables to follow for all directional diffusers.

• The table list performance data as a function of the air velocity in the neck of the diffuser.

• It lists several sizes for each core pattern and gives the neck area, expressed in m2, for each diffuser size. Performance factors listed are the air volume delivered through the diffuser, the NC level, the air volume delivered through each side of the diffuser, and two values of throw.

• The values of throw shown in the Tables are bases upon studies of air motion in the occupied zone under conditions of cooling systemoperation.

• When a diffuser is equipped with an opposed blade damper (OBD), both the total pressure requirement and the NC level increase.

• The OBD increases the total pressure require-ment of a diffuser by 10 percent.

• The NC addition, when the OBD is wide open, can be determined from Table 4.

• When the OBD is throttled, the NC factor for the throttled damper can be determined from Figure 17.

• The opposed blade action of the damper permits equal distribution of air over the entire face of the diffuser. The operating mechanism provides for positive damper setting in a position from fully open to fully closed.

• See holes on OBD for additional information.

• The allowance in the design of the system for outlet pressure loss should not be exceeded by the diffuser pressure loss.

• The room velocity, YR, should not exceed O.6m!s when the diffuser selection is based uponminimal throw.

• When diffuser selection is based upon maximum throw, the room velocity, YR, should not exceed O.4m!s. The tabulated values of throw apply for diffusers mounted in a ceiling.

• Selection data are given for neck velocities ranging from 1.5 to 3.5m!s

• Also listed are values of total pressure drop through the diffuser at each of these neck velocities.

• The total pressure requirement is the sum of the static pressure drop of the air as it passes through the diffuser and the velocity pressure of their air at the neck of the diffuser.

• If the static pressure is required, it can be deter-mined by subtracting the velocity pressure from the total pressure.

Details

CEILING DIFFUSERS 04

Page 5: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Note 1. “PB” Fits over neck of CD +/-2mm clearance all round 2. “CP” Fixed to neck of CD on request only 3. Refer selection data for standard size (increments 76mm)

Dimensions: "D" = Outside NeckCeling Opening = "D" + lOmmOver Flange = "D" + 120mm

TYPE CD: Ceiling Diffusers manufactured from Anodised Aluminium with Removeable Cores

Accessories OBD = Opposed Blade Damper remains in position when core is removed PB = Plenum Box with spigot CP = Ceiling Plate

Frame Options SF = Standard Flat SB = Standard Bevel on request only

Finish Options NA = Natural Anodised EPC = Epoxy Powder Coating Blade Spacing: 38mm Standard

Note: (1) Dimensions given are Outside Neck Size - "D" (2) Type CD Core 3A indicates Ceiling Diffuser with 3 way blow core

Type CD: Ceiling Diffuser available in a choice of air distribution patterns.

Note: T1 is always longer than T2 except in 3A where T1 = T2 All flow patterns are given looking at Diffuser face

Dimensions: "D" = Outside NeckCeling Opening = "D" + 75mmOver Flange = "D" + 130mm

Ordering Procedure: Example

Type - CD

CEILING DIFFUSERS 05

Page 6: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Note 1. “PB” Fits over neck of CD +/-2mm clearance all round 2. “CP” Fixed to neck of CD on request only 3. Refer selection data for standard size (increments 76mm)

Dimensions: "D" = Outside NeckCeling Opening = "D" + lOmmOver Flange = "D" + 120mm

TYPE CD: Ceiling Diffusers manufactured from Anodised Aluminium with Removeable Cores

Accessories OBD = Opposed Blade Damper remains in position when core is removed PB = Plenum Box with spigot CP = Ceiling Plate

Frame Options SF = Standard Flat SB = Standard Bevel on request only

Finish Options NA = Natural Anodised EPC = Epoxy Powder Coating Blade Spacing: 38mm Standard

Note: (1) Dimensions given are Outside Neck Size - "D" (2) Type CD Core 3A indicates Ceiling Diffuser with 3 way blow core

Type CD: Ceiling Diffuser available in a choice of air distribution patterns.

Note: T1 is always longer than T2 except in 3A where T1 = T2 All flow patterns are given looking at Diffuser face

Dimensions: "D" = Outside NeckCeling Opening = "D" + 75mmOver Flange = "D" + 130mm

Ordering Procedure: Example

Type - CD

CEILING DIFFUSERS 06

Page 7: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

General Notes On Selection

(i) "TOTAL VOLUME" means Total Volume per outlet.(ii) "THROW MIN-MAX" is to a terminal velocity of 0.75 m/s at Minimum throw and 0, 25rn1s at maximum throw.(iii) "VOLUME T1/T2" means volume per side i.e. T1/T2 = 0,092/0,040 means Volume on T1 = 0,092 and Volume on

T2 = 0, 040(iv) "T1 is always longer than "T2" except on type 3A where T1 = T2.(v) Noise Levels: "A" = Up to 30 dbA "B" = 31 to 40 dbA "C" = 41 to 50 dbA(vi) Ordering: When ordering T1 (longest side) is always given first (vii) Sizes shown refer to over outside neck.(viii) For sizes not shown please contact nearest sales office.(ix) Selection Example: Problem: Select a 4 way blow diffuser to delivery 0,25 m3/s with a throw of 3,5m in all directions. Solution: Use Size 381 x 381 Core 4A, Pressure drop = 15 N/m2. Noise level = A.

Performace Data

Type - CD

CEILING DIFFUSERS 07

Page 8: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Performace Data (Continued)

Type - CD

CEILING DIFFUSERS 08

Page 9: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Performace Data (Continued)

Type - CD

CEILING DIFFUSERS 09

Page 10: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Performace Data (Continued)

Type - CD

CEILING DIFFUSERS 10

Page 11: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Performace Data (Continued)

Type - CD

CEILING DIFFUSERS 11

Page 12: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Performace Data (Continued)

Type - CD

CEILING DIFFUSERS 12

Page 13: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Performace Data (Continued)

Type - CD

CEILING DIFFUSERS 13

Page 14: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Performace Data (Continued)

Type - CD

CEILING DIFFUSERS 14

Page 15: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Performace Data (Continued)

Type - CD

CEILING DIFFUSERS 15

Page 16: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

Type CP: Ceiling Plate manufactured of electro galvanized flat sheet for installation in lay-in "T" Bar suspended ceiling system.It is easily relocated to meet changing space requirements.It also fits all common suspended grid ceilings, and are available with epoxy powder coating finish to your colour requirements.

Ordering Procedure - Example

Ceiling Plate - CP

CEILING DIFFUSERS 16

Page 17: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

TYPE CAB: Curved Adjustable Blades - Ceiling Diffuser Manufactured of extruded type 50S Anodising Grade Aluminium with individually adjustable blade. The blades are held in place by plastic friction grommets or wire.

Accessories PCS = Punched Counter Sunk Holes OBD = Opposed Blade Damper PB = Plenum Box with spigot CP = Ceiling Plate

Frame Options 30mm Standard ON = Over Neck 20mm OS = Over Flange 50mm OP = Opening or Normal Duct Size

Finish Options WS = Wet Spray Colour NA = Natuaral Anodised Aluminium

Blade Spacing: 19mm Standard

Type CAB - Ceiling Diffuser available in a choice of Air Distribution PatternsNote: H1 is always longer than H2 All Flow Patterns are given looking at difuuser face

Ordering Procedure - Example

Note: (1) Dimensions given are for over Flange size (2) Type CAB Core 2A indicates CAB with two way blow

Type - CAB

CEILING DIFFUSERS 17

Page 18: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

GENERAL NOTES ON SELECTIONS

A) TOTAL VOLUME MEANS TOTAL VOLUME PER OUTLET - m3/sec.

B) THROW MIN-MAX IS TO A TERMINAL VELOCITY OF 0.64 MIS MINIMUM THROW AND 0.031 MIS AT

MAXIMUM THROW.

C) VOLUME HI + H2 MEANS VOLUME PER RESPECTIVE SIDE.

D) HI IS ALWAYS LARGER THAN H2 , EXCEPT ON TYPE 3A WHERE Hl=H2.

E) NOISE (NC) LEVEL

A = 0-30 B = 31-35 C = 36-40 D = 41-45

SELECTION OF CURVED ADJUSTABLE BLADE GRILLE IS BASED UPON THROW AND M3/S REQUIREMENTS. THE THROW, M3/S AND PRESSURE DROP APPLY WHEN THE INDIVIDUAL BLADES ARE ADJUSTED IN THE MANNER ILLUSTRATED BELOW. OTHER BLADE SETTINGS WILL PROVIDE SIGNIFICANTLY DIFFERENT THROWS AND AIR DELIVERIES.

THE M3/S TABULATED IS THE VOLUME DELIVERED BY THE GRILLE. BALANCING OF CURVED BLADE IS ACCOM-PLISHED BY MEASURING FACE VELOCITY. THE MEASURED VELOCITY CAN BE CORRELATED TO TABULATED FACE VELOCITY AND M3/S WHEN THE BLADES ADJUSTMENT IS THAT AS ILLUSTRATED.

THE PERFORMANCE OF RECTANGULAR GRILLES WITH AREAS EQUAL TO SQUARE GRILLES, WILL BE THE SAME.

Type - CAB

CEILING DIFFUSERS 18

Page 19: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

CORE PATTERN

SELECTION DATA

Type - CAB

CEILING DIFFUSERS 19

Page 20: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

CORE PATTERN

SELECTION DATA

Type - CAB

CEILING DIFFUSERS 20

Page 21: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

CORE PATTERN

SELECTION DATA

Type - CAB

CEILING DIFFUSERS 21

Page 22: CONTROL THE AIR YOU BREATHE - Europair  · PDF fileCONTROL THE AIR YOU BREATHE ADJUSTABLE BLADE CEILING DIFFUSER - CAB FIXED BLADE CEILING DIFFUSER - CD FEATURES •

C O N T R O L T H E A I R Y O U B R E A T H E

CORE PATTERN

SELECTION DATA

Type - CAB

CEILING DIFFUSERS 22