continue fcu150 trash compactor. normal modedelay mode
TRANSCRIPT
![Page 1: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/1.jpg)
Continue
FCU150 FCU150 Trash CompactorTrash Compactor
![Page 2: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/2.jpg)
Normal Mode Delay Mode
![Page 3: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/3.jpg)
Normal Operation
Unit shown above in the OFF position, ram up.
><
![Page 4: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/4.jpg)
Normal Operation
Key switched to the “ON” position. Ram Lock Switch engaged.
><
![Page 5: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/5.jpg)
Normal Operation
><
START button depressed – Door closed. Door Interlock Switch and Door Sensor Switch engage.
![Page 6: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/6.jpg)
Normal Operation
Start Relay on PCB activates and supplies 120 volts to Run and Start winding. Ram starts downwards.
><
![Page 7: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/7.jpg)
Normal Operation
><
Centrifugal switch N.C contact opens so start winding drops out and N.O. contact closes.
![Page 8: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/8.jpg)
Normal Operation
><
The Start relay disengages and the Upper Limit Switch closes and supplies 120 volts to RUN winding.
![Page 9: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/9.jpg)
Normal Operation
><
At the same time the upper limit switch activates, so does the upper limit directional switch which will allow the Up Start winding to engage when ready.
![Page 10: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/10.jpg)
Normal Operation
><
When the ram is all the way down, the Lower Limit Switch is closed, supplying neutral to the “UP” Start winding.
![Page 11: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/11.jpg)
Normal Operation
><
The Motor switches direction and begin to turn in the opposite direction, bringing the ram upwards
![Page 12: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/12.jpg)
Normal Operation
><
The Lower Limit Switch opens and removes the Neutral to the Start winding. The ram continues upwards.
![Page 13: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/13.jpg)
Normal Operation
><
When the ram gets to the top position, the Upper Limit Switch is activated. Power is interrupted to the Run Winding and the motor
stops.
![Page 14: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/14.jpg)
Normal Operation
><
At the same time, the Upper Limit Directional switch is also activated and is ready for the next cycle. COMPACTION COMPLETE!
Delay Mode
![Page 15: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/15.jpg)
Delay Operation
Unit shown above in the OFF position, ram up.
><
![Page 16: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/16.jpg)
Delay Operation
Key switched to the “ON” position. Ram Lock Switch engaged.
><
![Page 17: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/17.jpg)
Delay Operation
><
DELAY START button depressed – Door closed. Door Interlock Switch and Door Sensor Switch engage.
![Page 18: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/18.jpg)
Delay Operation
At the predetermined “Start” time, the Compact Mode and Start Relays on the PCB activate. 120 volts is supplied to Run and Start winding via the "C" terminal of the Upper Limit Switch. The ram starts downwards.
><
![Page 19: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/19.jpg)
Delay Operation
><
Centrifugal switch N.C contact opens so start winding drops out and N.O. contact closes.
![Page 20: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/20.jpg)
Delay Operation
><
The Start relay disengages and the Upper Limit Switch closes.
![Page 21: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/21.jpg)
Delay Operation
><
Line voltage from the Upper Limit Switch is now directed through the C and N.O contact (Now closed) in the Compact Mode Relay. Voltage is sent through the closed centrifugal switch contact to the motor run winding.
![Page 22: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/22.jpg)
Delay Operation
><
The Upper Limit Switch (Directional) is also switched to the N.C position. It will now be ready to engage the START UP winding when required
![Page 23: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/23.jpg)
Delay Operation
><
When the ram is all the way down, the Lower Limit Switch is closed, supplying neutral to the “Start UP” winding.
![Page 24: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/24.jpg)
Delay Operation
><
With Neutral applied to the “Start Up” winding, the motor is stopped, allowing the centrifugal switch contact which has been supplying line voltage to the Run winding. The motor stops and the ram is in the COMPACT Mode. This will stay like this for 2 hours.
![Page 25: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/25.jpg)
Delay Operation
><
At the end of the 2 hour delay, the Compact Mode Relay releases and engages the N.C contact. This allows line voltage to flow to the RUN and START UP windings via the Upper Limit Switch.
![Page 26: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/26.jpg)
Delay Operation
><
The Centrifugal Switch activates and the Lower Limit Switch opens which removes the Neutral to the START UP winding. The ram continues upwards.
![Page 27: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/27.jpg)
Delay Operation
><
When the ram gets to the top position, the Upper Limit Switch is activated. Power is interrupted to the Run Winding and the motor
stops.
![Page 28: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/28.jpg)
Delay Operation
><
At the same time, the Upper Limit Directional switch is also activated and is ready for the next cycle. COMPACTION COMPLETE!
Normal Mode
![Page 29: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/29.jpg)
This concludes or This concludes or training training
presentationpresentationEND
![Page 30: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/30.jpg)
Door sensing Switch
Door Sensing SwitchDoor Sensing Switch
Return
![Page 31: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/31.jpg)
Door interlock Switch
Door Interlock SwitchDoor Interlock Switch
Return
![Page 32: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/32.jpg)
Ram Lock Switch
Ram lock SwitchRam lock Switch
Return
![Page 33: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/33.jpg)
Key Switch
Key SwitchKey Switch
Return
![Page 34: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/34.jpg)
Power PCB ControlPower PCB Control
Return
![Page 35: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/35.jpg)
Lower Limit SwitchLower Limit Switch
Return
![Page 36: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/36.jpg)
Ram Up Sensor Switch - LVRam Up Sensor Switch - LV
Return
![Page 37: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/37.jpg)
Upper Limit SwitchUpper Limit Switch
Return
![Page 38: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/38.jpg)
Upper Limit Switch Upper Limit Switch (Directional)(Directional)
Return
![Page 39: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/39.jpg)
Odor Disc Sensor Odor Disc Sensor SwitchSwitch
Return
![Page 40: Continue FCU150 Trash Compactor. Normal ModeDelay Mode](https://reader036.vdocuments.us/reader036/viewer/2022081603/5697bf8e1a28abf838c8ce0f/html5/thumbnails/40.jpg)
Odor Disc Motor Odor Disc Motor AssemblyAssembly
Return