February 2007 CA08101001E For more information visit: www.eaton.com Contents Power Outlet Panels 6-1 6 Power Outlet Panels Description Page Power Outlet Panels Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5 Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5 Power Outlet Panel Receptacle Configuration Rules . . . . . . . . . . . . . . . . 6-6 Unmetered Surface Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Metered Surface Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Unmetered Pedestal Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8 Metered Pedestal Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8 Unmetered Back-to-Back Pedestal Type . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8 Metered Back-to-Back Pedestal Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8 Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9 Accessories and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-15 Mobile Home Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-16 Receptacle Deadfront Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-16 Don’t Give Up! If you don’t find the product you want in this catalog, try the Flex Center at 1-800-330-6479. Power Outlet Panel Family

Upload: dohanh

Post on 05-Jun-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

February 2007

CA08101001E For more information visit:

www.eaton.com

Contents

Power Outlet Panels 6-1

6

Po

wer

Ou

tlet

Pan

els

Description Page

Power Outlet Panels

Surface Units

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-3

Pedestal Units

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-3

Product Selection

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-5

Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-5

Power Outlet Panel Receptacle Configuration Rules . . . . . . . . . . . . . . . .

6-6

Unmetered Surface Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-7

Metered Surface Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-7

Unmetered Pedestal Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-8

Metered Pedestal Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-8

Unmetered Back-to-Back Pedestal Type. . . . . . . . . . . . . . . . . . . . . . . . . . .

6-8

Metered Back-to-Back Pedestal Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-8

Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-9

Accessories and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-15

Mobile Home Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-16

Receptacle Deadfront Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-16

Don’t Give Up!

If you don’t find the product you want in this catalog, try the Flex Center at

1-800-330-6479

.

Power Outlet Panel Family

February 2007

6-2

For more information visit:

www.eaton.com

CA08101001E

Power Outlet Panels

6

Product Description

Product Description

A Power Outlet Panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and recreation vehicle (RV) parks. Construction sites and RV parks need to provide a safe and reliable means for users to access electricity and POPs provide the outlets for electrical access.

Application Description

Power Outlet Panels or POPs are also sometimes called Temporary Power Panels, Temporary Site Service Equipment or RV Panels.

Construction Site Application

When POPs are used at a construction site, they are installed on a temporary basis until electrical power is available at the building. The most common rea-son for needing a POP at a construc-tion site is to provide a power source for the contractor’s tools.

Construction Site Application

RV Park Application

When POPs are used at an RV park, they are installed for more permanent use and serve the purpose of provid-ing power to the vehicle’s appliances. Many RV parks now supply users with lighted POPs with TV and telephone jacks. A move towards offering more amenities at RV parks.

RV Park Application

Standards and Certifications

UL

Standard 231.

UL File Number E163588.

Receptacles conform to NEMA

and/or ANSI configurations as specified by the National Electrical Code

.

Product Specifications

The power outlet panels shall be designed for outdoor service to meet temporary power outlet requirements at construction sites and provide high quality, economical power to individual sites at recreational vehicle (RV) parks. Construction site panels shall be pro-vided with means to bond the neutral for service entrance applications. RV panels shall have a factory-installed insulated neutral bar.

Receptacles and Circuit Protection

The circuit protection shall be Eaton’s Cutler-Hammer

UL listed full-size Type BR or half-size Type BD circuit breakers. The receptacles shall be NEMA commercial/industrial grade and come in a wide variety of configurations. Ground fault protec-tion (GFCB) shall be provided at the 20 ampere duplex NEMA 5-20R recep-tacle or 20 ampere single-pole circuit breaker when required. Ground fault protection shall be provided at the circuit breaker for receptacles above 20 amperes when required.

Construction

The power outlet panel pedestal shall be of deadfront design and constructed of heavy gauge, 100 percent galvanized steel. Baked-on polyester powder coating shall be used for excellent mechanical strength, plus resistance to chalking caused by the sun’s ultraviolet rays. The power outlet panel surface and pedestal units shall have NEMA Type 3R rainproof enclosures.

Ease of Installation

Panels shall ship from the factory completely assembled, prewired with 100 percent copper wire, and tested in accordance with UL Standard 231. Door shall swing up and open for user convenience and ease of access to breakers and receptacles. When required, a means for securing the door in the open position shall be provided. Panels shall be bottom fed through knockouts in endwall or top fed using a bolt-on raintight hub. Knockouts shall range from 1/2-inch (12.7 mm) to 1-1/2 inches (38.1 mm). #4 – 14 Cu/Al grounding provisions shall be provided on all panels.

Standard Compliance

All power outlet panels for temporary construction site power and RV (recre-ational vehicle) application shall be UL listed for the U.S. per UL Standard 231, File E163588. Receptacles shall conform to NEMA and/or ANSI config-urations as specified by the National Electrical Code (NEC).

February 2007

CA08101001E For more information visit:

www.eaton.com

6-3Power Outlet Panels

6

Surface and Pedestal Units

Eaton’s Cutler-Hammer Power Outlet Panels

Power Where You Need It, When You Need It

Features

Designed for outdoor service to meet power outlet requirements.

Receptacles conform to NEMA and/or ANSI configurations as specified by NEC.

Suitable for use as service entrance equipment.

Includes a factory installed insulated neutral bar with provisions for bonding when used for service entrance applications.

125 ampere rated meter socket.

Designed for Easy Installation and Protection

Panels come from the factory completely assembled, prewired with 100 percent copper wire and tested...ready for easy installation.

Door swings up and open for user convenience and ease of access to breakers and receptacles.

Panels can be bottom fed through knockouts in endwall or top fed using a bolt-on raintight hub.

Two-piece deadfront cover allows field wiring without interfering with factory wiring.

Lower deadfront cover permits easy field wiring to circuit protective devices.

GFI (ground fault interrupter) 1- and 2-pole protection through 50 amperes.

Two Styles to Meet Your Power Outlet Needs

Surface Mount:

User mounts unit to a post.

Pedestal Mount:

User mounts with an underground pedestal extension or pad-mounting bracket. (Underground pedestal extension and pad-mounting bracket are sold separately. See acces-sories

Page 6-15

for part numbers and options.)

Surface Units

Pedestal Units

Lighted option for site location and nighttime panel operations.

Three-point mounting.

100 percent galvanized steel with baked-on polyester powder coating.

GFI circuit breakers available through 50 amperes.

One-piece case back for metered and unmetered panels.

Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked.

Lower deadfront cover rotates 90 degrees or can be removed for easy routing of incoming wires or receptacle changeouts.

Padlock provisions to prevent unauthorized entry.

Utility grade metering available for construction site RV park applications.

Removable upper deadfront cover for easy incoming wire connections to breaker terminals.

• Units are factory wired and assembled.

NEMA 3R construction for rainproof installation.

Door swings up and pushes in to lock into open position. Pull out and push down to close door.

• Metered units available with meter on top or on bottom.

• Units are factory wired and assembled.

100 percent galvanized steel with baked-on polyester powder coating.

GFI circuit breakers (1- and 2-pole) available through 50 amperes.

One-piece case back for metered and unmetered panels.

Removable upper deadfront cover for easy incoming wire connections to breaker terminals.

Door swings up and pushes in to lock into open position. Pull out and push down to close door.

Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked.

Lower deadfront cover rotates 90 degrees or can be removed for easy routing of incoming wires or receptacle changeouts.

Padlock provisions to prevent unauthorized entry.

Loop feed lug assembly with 350 kcmil lugs as standard.

Pad-mounted bracket option also available.

Pedestal extension available for underground services.

Utility grade metering available for construction site RV park applications.

NEMA 3R construction forrainproof installation.

February 2007

6-4

For more information visit:

www.eaton.com

CA08101001E

Power Outlet Panels

6

Surface and Pedestal Units

Cutler-Hammer Power Outlet Panels

Surface Units

Pedestal Units

Unmetered Type

Metered Ring or Ringless Type Back-to-Back Type

Unmetered Type Metered Ring or Ringless Type Metered Ring or Ringless Type Bottom Feed

Single Receptacle

February 2007

CA08101001E For more information visit:

www.eaton.com

6-5Power Outlet Panels

6

Product Selection

Product Selection

When quoting or selecting a Power Outlet Panel, the following questions should be answered:

Unmetered, Ring or Ringless Style.

Number and types of receptacles (7 standard and 8 twist-lock options).

Standard or Ground Fault Breakers.

Surface, Pedestal or Back-to-Back Mounting.

Are any factory or field options required?

Table 6-1. Catalog Numbering System

For receptacle configurations, see

Table 6-2

.

Only available with metered surface mount units.

Note:

Twist-lock receptacles are not listed in the above chart as not all receptacle combinations are valid even though one can create a catalog number above.

Contact Eaton for a quote on twist-lock and custom receptacle/breaker combinations.

Table 6-2. Receptacle Configuration

1

50 ampere, 125/250 volt3-pole, 4-wire,

NEMA 14-50R

2-pole 50 ampere breaker

5

20 ampere, 250 volt,2-pole, 3-wire,

NEMA 6-20R2

2-pole 20 ampere breaker

2

50 ampere, 125/250 volt2-pole, 3-wire, NEMA 10-50R

2-pole 50 ampere breaker

6 20 ampere, 125 volt,2-pole, 3-wire, NEMA 5-20R2

1-pole 20 ampere breaker

3 30 ampere, 125/250 volt3-pole, 4-wire, NEMA 14-30R

2-pole 30 ampere breaker

7 20 ampere, 125 volt,2-pole, 3-wire, NEMA 5-20R2GFI

1-pole 20 ampere breaker

4 30 ampere, 125 volt2-pole, 3-wire,

NEMA TT-30R

1-pole 30 ampere breaker

Cutler-Hammer

Metering Type

U = UnmeteredM = Metered-RingR = Metered-Ringless

Receptacle Type

Left Position �

1 = NEMA 14-50R2 = NEMA 10-50R3 = NEMA 14-30R4 = NEMA TT-30R5 = NEMA 6-20R26 = NEMA 5-20R27 = NEMA 5-20R2GFI

Blank = No Receptacle

Receptacle Type

Center Position �

1 = NEMA 14-50R2 = NEMA 10-50R3 = NEMA 14-30R4 = NEMA TT-30R5 = NEMA 6-20R26 = NEMA 5-20R27 = NEMA 5-20R2GFI

Blank = No Receptacle

Mounting

S = SurfaceP = PedestalB = Back-to-Back

Pedestal

Interior

X = Six CircuitBlank = Standard

Four Circuit

L = Lighted

TZ = Factory InstalledPedestal Extensionwith Lay-inGround Lug

C H M 1 N 7 N 4 N P X L T Z U

Receptacle Type

Right Position �

1 = NEMA 14-50R2 = NEMA 10-50R3 = NEMA 14-30R4 = NEMA TT-30R5 = NEMA 6-20R26 = NEMA 5-20R27 = NEMA 5-20R2GFI

Circuit Breaker TypePosition 2

N = Non-Ground FaultG = Ground Fault

Feed

U = Bottom Fed �Blank = Top Fed

Circuit Breaker TypePosition 3

N = Non-Ground FaultG = Ground Fault

Circuit Breaker TypePosition 1

N = Non-Ground FaultG = Ground Fault

February 2007

6-6

For more information visit: www.eaton.com CA08101001E

Power Outlet Panels

6

Product Selection

Product Selection

Built to Order■ Configure catalog number.■ Calculate list price.■ Lead-time:

❑ 3 days up to 15 units❑ 10 days up to 50 units

Power Outlet Panel ReceptacleConfiguration Rules

Four Receptacles/UnitAll receptacles must be NEMA 5-20R and/or NEMA 5-20R2, surfacemount only.

Three Receptacles/Unit

■ One or more of the receptacles must be NEMA 6-20R2, NEMA 5-20R2 or NEMA 5-20R2GFI.

■ NEMA 6-20R2, NEMA 5-20R2, or NEMA 5-20R2GFI must go in the second position.

■ If two receptacles consist of types NEMA 14-50R, NEMA 10-50R, NEMA 14-30R or NEMA 6-20R2 a six-circuit interior must be added.❑ Example: CHUIN5N2NSX

Note: Configuration 1 and 2 werechosen so a six-circuit interior needsto be added (suffix X) to the end ofthe catalog number. Also, configura-tion 5 is in the second position.

Two, One and Zero Receptacles/Unit■ Any configuration.

Power Outlet Panel List Price ConfiguratorTable 6-3. Base Price

Note: Contact your local Eaton sales office for current pricing.

Table 6-4. Receptacle/Breaker Adders

Note: Contact your local Eaton sales office for current pricing.

Table 6-5. Options

Note: Contact your local Eaton sales office for current pricing.

Description PriceU.S. $

Unmetered SurfaceMetered Surface

Unmetered PedestalMetered Pedestal

Unmetered Back-to-BackMetered Back-to-Back

Configuration Description PriceU.S. $

1N1G

NEMA 14-50R with 2-Pole 50 Ampere Breakerwith 2-Pole 50 Ampere GFI Breaker

2N2G

NEMA 10-50R with 2-Pole 50 Ampere Breakerwith 2-Pole 50 Ampere GFI Breaker

3N3G

NEMA 14-30R with 2-Pole 30 Ampere Breakerwith 2-Pole 30 Ampere GFI Breaker

4N4G

NEMA TT-30R with 1-Pole 30 Ampere Breakerwith 1-Pole 30 Ampere GFI Breaker

5N5G

NEMA 6-20R2 with 2-Pole 20 Ampere Breakerwith 2-Pole 20 Ampere GFI Breaker

6N6G

NEMA 5-20R2 with 1-Pole 20 Ampere Breakerwith 1-Pole 20 Ampere GFI Breaker

7N NEMA 5-20R2GFI with 1-Pole 20 Ampere Breaker

Option PriceU.S. $

Six Circuit InteriorFactory-Mounted Pedestal ExtensionLightedBottom Fed

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD

February 2007

CA08101001E For more information visit: www.eaton.com

6-7Power Outlet Panels

6

Product Selection

Product Selection (Continued)Table 6-6. Surface Type

� Consult Power Outlet Estimator on Eaton’s intranet for additional combinations. Contact your local Eaton salesperson.� The “X” suffix indicates that a six circuit interior is provided, instead of the standard four circuit interior.� Includes 60 ampere 2-pole main breaker for service disconnect ratings.Note: For receptacle and circuit breaker configurations, please contact your local Eaton salesperson.Note: Contact your local Eaton sales office for configurations not listed.

AmpereSeries

Receptacle Description Breaker Description UPC Number78211

CatalogNumber �

PriceU.S. $Position 1st 2nd 3rd

Left Center Right

Unmetered Single Receptacle50503030

————

14-50R10-50R14-30 RTT-30R

————

No BreakerNo BreakerNo BreakerNo Breaker

No BreakerNo BreakerNo BreakerNo Breaker

No BreakerNo BreakerNo BreakerNo Breaker

6128174612818161281986128204

CHU1SCHU2SCHU3SCHU4S

202020

———

6-20R25-20R25-20R2GFI

———

No BreakerNo BreakerNo Breaker

No BreakerNo BreakerNo Breaker

No BreakerNo BreakerNo Breaker

612821161282286128235

CHU5SCHU6SCHU7S

Unmetered20/20/2020/20/2020/20/20

5-20R25-20R2GFI5-20R2GFI

5-20R25-20R2GFI5-20R2GFI

6-20R26-20R26-20R2

GFINon-GFINon-GFI

GFINon-GFINon-GFI

GFINon-GFIGFI

42039 242039 4—

CHU6G6G5GSCHU7N7N5NSCHU7N7N5GS

50/20/3050/20/3030/20

5-20R2GFI14-50RTT-30R

5-20R2GFI5-20R2GFI5-20R2GFI

TT-30R6-20R—

Non-GFIGFINon-GFI

Non-GFINon-GFINon-GFI

Non-GFINon-GFI—

——42037 4

CHU1N7N4NSCHU1G7N7NSCHU4N7NS

20/2050/2050/20

5-20R2GFI14-50R14-50R

5-20R2GFI5-20RGFI5-20RGFI

———

Non-GFIGFINon-GFI

Non-GFINon-GFINon-GFI

———

42037 742156 842037 0

CHU7N7NSCHU1G7NSCHU1N7NS

50/20/505050/20

14-50R14-50R10-50R

5-20R2GFI—5-20R2GFI

14-50R——

Non-GFINon-GFIGFI

Non-GFI—Non-GFI

Non-GFI——

——42156 9

CHU1N7N1NSX �

CHU1NSCHU2G7NS

30/30/2050/2030

TT-30R10-50RTT-30R5-20R2

5-20R2GFI5-20R2GFI—5-20R2

TT-30R——5-20R2

Non-GFINon-GFINon-GFIGFI

Non-GFINon-GFI—GFI

Non-GFI——GFI

42039 042037 242036 7

CHU4N7N4NSCHU2N7NSCHU4NSCHU6G6G5GS6OM �

Metered — Ring50/20/2020/2020/20/20

14-50R5-20R2GFI5-20R2GFI

5-20R2GFI5-20R2GFI5-20R2GFI

5-20R2GFI—6-20R2

GFINon-GFINon-GFI

Non-GFINon-GFINon-GFI

Non-GFI—GFI

42028 642028 342156 1

CHM1G7N7NSCHM7N7NSCHM7N7N5GS

20/20/2050/30/2050/2020/20

5-20R2GFI14-50R14-50R6-20R2

5-20R2GFI5-20R2GFI5-20R2GFI5-20R2GFI

6-20R2TT-30R——

Non-GFINon-GFINon-GFINon-GFI

Non-GFINon-GFINon-GFINon-GFI

Non-GFINon-GFI——

42030 042028 842027 742156 3

CHM7N7N5NSCHM1N7N4NSCHM1N7NSCHM5N7NS

Metered — Ringless50/2020/2050/20/20

14-50R5-20R2GFI14-50R

5-20R2GFI5-20R2GFI5-20R2GFI

——5-20R2GFI

GFINon-GFIGFI

Non-GFINon-GFINon-GFI

——Non-GFI

42190 742032 942398 3

CHR1G7NSCHR7N7NSCHR1G7N7NS

50/2050/2020/20/20

10-50R14-50R5-20R2GFI

5-20R2GFI5-20R2GFI5-20R2GFI

——5-20R2GFI

GFINon-GFINon-GFI

Non-GFINon-GFINon-GFI

——Non-GFI

42398 242032 442034 7

CHR2G7NSCHR1N7NSCHR7N7N7NS

30/20/2050/30/20

14-30R14-50R

5-20R2GFI5-20R2GFI

5-20R2GFITT-30R

Non-GFINon-GFI

Non-GFINon-GFI

Non-GFINon-GFI

42034 142033 4

CHR3N7N7NSCHR1N7N4NS

Metered — Ring — Bottom Fed20/2020/20/2050/20/20

5-20R2GFI5-20R2GFI14-50R

5-20R2GFI5-20R2GFI5-20R2GFI

—6-20R25-20R2GFI

Non-GFINon-GFIGFI

Non-GFINon-GFINon-GFI

—GFINon-GFI

615327 5615330 5615329 9

CHM7N7NSUCHM7N7N5GSUCHM1G7N7NSU

Metered — Ringless — Bottom Fed20/2050/2050/20

5-20R2GFI14-50R10-50R

5-20R2GFI5-20R2GFI5-20R2GFI

———

Non-GFIGFIGFI

Non-GFINon-GFINon-GFI

———

615326 8615328 2615338 1

CHR7N7NSUCHR1G7NSUCHR2G7NSU

20/20/2020/20/2020/20/20

5-20R2GFI5-20R2GFI5-20R2GFI

5-20R2GFI5-20R2GFI5-20R2GFI

6-20R26-20R25-20R2GFI

Non-GFINon-GFINon-GFI

Non-GFINon-GFINon-GFI

GFINon-GFINon-GFI

615331 2615332 9615337 4

CHR7N7N5GSUCHR7N7N5NSUCHR7N7N7NSU

30/20/2030/20/2050/20/2050/20/30

14-30R14-30R14-50R14-50R

5-20R2GFI5-20R2GFI5-20R2GFI5-20R2GFI

5-20R2GFI5-20R2GFI5-20R2GFITT-30R

Non-GFIGFIGFINon-GFI

Non-GFINon-GFINon-GFINon-GFI

Non-GFINon-GFINon-GFINon-GFI

615333 6615334 3615336 7615335 0

CHR3N7N7NSUCHR3G7N7NSUCHR1G7N7NSUCHR1N7N4NSU

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 22CD

February 2007

6-8

For more information visit: www.eaton.com CA08101001E

Power Outlet Panels

6

Product Selection

Table 6-7. Pedestal Type

� Consult Power Outlet Estimator on Eaton’s intranet for additional combinations. Contact your local Eaton salesperson.Note: For receptacle and circuit breaker configurations, please contact your local Eaton salesperson.Note: Contact your local Eaton sales office for configurations not listed.

Table 6-8. Back-to-Back Pedestal Type

� Consult Power Outlet Estimator on Eaton’s intranet for additional combinations. Contact your local Eaton salesperson.� The pedestal back-to-back units have receptacles and circuit breakers as shown for each panel and share one common pedestal with loop feed lugs.Note: For receptacle and circuit breaker configurations, please contact your local Eaton salesperson.Note: Contact your local Eaton sales office for configurations not listed.

AmpereSeries

Receptacle Description Breaker Description UPCNumber78211

CatalogNumber �

PriceU.S. $Position 1st 2nd 3rd

Left Center Right

Unmetered50/30/2030/20

14-50RTT-30R

5-20R2GFI5-20R2GFI

TT-30R—

Non-GFINon-GFI

Non-GFINon-GFI

Non-GFI—

42038 242031 7

CHU1N7N4NPCHU4N7NP

50/30/2030/30/20

14-50RTT-30R

5-20R2GFI5-20R2GFI

TT-30RTT-30R

Non-GFINon-GFI

Non-GFINon-GFI

Non-GFINon-GFI

42038 342032 1

CHU1N7N4NPTZCHU4N7N4NP

Metered — Ring50/30/2050/20

14-50R14-50R

5-20R2GFI5-20R2GFI

TT-30R—

Non-GFINon-GFI

Non-GFINon-GFI

Non-GFI—

42030 442231 5

CHM1N7N4NPCHM1N7NP

Metered — Ringless50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI 42031 0 CHR1N7N4NP

AmpereSeries

Receptacle Description Breaker Description UPCNumber78211

CatalogNumber �

PriceU.S. $Position 1st 2nd 3rd

Left Center Right

Unmetered �

30/30/20 TT-30R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI 42036 4 CHU4N7N4NB

Metered — Ring �

30/2050/30/20

TT-30R14-50R

5-20R2GFI5-20R2GFI

—TT-30R

Non-GFINon-GFI

Non-GFINon-GFI

—Non-GFI

42034 842035 0

CHM4N7NBCHM1N7N4NB

Metered — Ringless �

50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI 42035 7 CHR1N7N4NBTZ

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD

February 2007

CA08101001E For more information visit: www.eaton.com

6-9Power Outlet Panels

6

Product Selection

Dimensional Drawings

Figure 6-1. Single Receptacle

6.58 (167.1)

2.63 (66.8)

0.24 (6.1)

7.10 (108.3)

4.50 (114.3)

1.30 (33.0)

6.23 (158.2)

2.50 (63.5)

1.87 (47.5 )

3.18 (80.8)

4.79 (121.7)

4.27 (108.5)

0.13 (3.3)

February 2007

6-10

For more information visit: www.eaton.com CA08101001E

Power Outlet Panels

6

Product Selection

Figure 6-2. 100 Amperes Back-to-Back

RinglessU.G. Feed Pedestal-Mount B/B

33.00(838.2)

8.25

18.02(457.7)

Hit ExitHoleB/B Only

33.00(838.2)

February 2007

CA08101001E For more information visit: www.eaton.com

6-11Power Outlet Panels

6

Product Selection

Figure 6-3. 100 Ampere Pedestal

Gasket

RinglessU.G. Feed Pedestal-Mount.

6.10(154.9)

33.00(838.2)

18.02

Hit ExitHole B/BOnly

0.24260.0)

4.00

10.78(273.7)

wer Barrier

.79(20.1)

.92 (23.4)

33.00(838.2)

February 2007

6-12

For more information visit: www.eaton.com CA08101001E

Power Outlet Panels

6

Product Selection

Dimensions in Inches (mm) — Metered Units (Ring and Ringless)

Figure 6-4. Metered Surface Type

Figure 6-5. Metered Pedestal Type

SealingProvision

LockingProvision

9.50

22.50(571.5)

30.00(762.0)

4.50(114.3)

.074.30

(170.1)

SealingProvision

LockingProvision

9.50(241.3)

52.00(1320.8)

25.80(655.3)

16.90(429.3)

44.50(1130.3)

22.00(558.8)

6.80(172.7)

5.00(127.0) 4.30

(109.2)

February 2007

CA08101001E For more information visit: www.eaton.com

6-13Power Outlet Panels

6

Product Selection

Dimensions in Inches (mm) — Metered Units (Ring and Ringless)

Figure 6-6. Metered Back-to-Back Pedestal Type

Figure 6-7. Bottom Fed Type

9.49(241.1)

30.10(764.6)

SealingProvision

6.15(156.2)

17.11(434.7)

12.97(329.4)

4.93(125.2)

LockingProvision

6.80(172.8)

4.31

.06(1.6)

February 2007

6-14

For more information visit: www.eaton.com CA08101001E

Power Outlet Panels

6

Product Selection

Figure 6-8. Unmetered Surface Type

Figure 6-9. Unmetered Pedestal Type

Dimensions in Inches (mm) — Unmetered Units

LockingProvision

9.50(241.3)

17.10(434.3)

6.70(170.2)

1.30(33.0)

14.50(368.3)

4.30(109.2)

.07(1.7)

9.50(241.3)

39.90(1013.5)

39.10(993.1)

9.40(238.8)

9.20(233.7)

Figure 6-10. Unmetered Back-to-Back Pedestal Type

LockingProvision

17.10(434.3)

13.60(345.4)

8.60(218.4)

19.20(487.7)

3.30(83.8).75

(19.1)

9.50

CA08101001E For more information visit: www.eaton.com

6-15Power Outlet Panels

February 2007

6

Accessories and Replacement Parts

Accessories and Replacement PartsTable 6-9. Accessories and Replacement Parts

� For Power Outlet Panels manufactured before 12/1/02.� For Power Outlet Panels manufactured after 12/1/02.� For Power Outlet Panels with a date code ending in L.� For Power Outlet Panels with a date code not ending in L.

Description UPCNumber78211

CatalogNumber

PriceU.S. $

AccessoriesUnderground Pedestal ExtensionStainless Steel Underground Pedestal ExtensionPad-Mount Bracket

420273422130420274

CHPEDEXTCHPEDEXTSSCHPADEXT

Cable TV and Telephone Bracket 420275 CHTELTV

Rainproof Conduit Hub 0.75 inch (19.1 mm)Rainproof Conduit Hub 1.00 inch (25.4 mm)Rainproof Conduit Hub 1.25 inch (31.8 mm)Rainproof Conduit Hub 1.50 inch (38.1 mm)

310991310992310993310994

DS075H1DS100H1DS125H1DS150H1

Fluorescent Light Kit — Converts power outlet panel to lighted unit, must also order CHOUTCVRL. 463424 CHFLGTKIT

Replacement PartsReplacement Meter Socket �Replacement Meter Socket �Replacement Meter Socket (1 Block Assembly Per Kit) �

481999612728603686

CHPOPMSCHPOPMSNARP00039CH

5th Jaw Kit �5th Jaw Kit �Bonding Strap and Mounting HardwareHorn Bypass (1 Lug Cap Per Kit; 4 Kits Required Per Device) �Horn Bypass (1 Kit Required Per Device) �

600788400413421926612840438033

1MM5JKOPARP00035CHJCHBONDSTARP00777CH1MMBPH

Inner Lens for Lighted Power Outlet Panels Loop Feed Lug Assembly for Single PedestalLoop Feed Lug Assembly for Back-to-Back Pedestal

421927421928421929

CHINLENSCHLOOPFDPCHLOOPFDB

Blank Lower Deadfront CoverLower Deadfront Cover with Duplex Receptacle OpeningLower Deadfront Cover with Duplex, Duplex Receptacle Opening

421930421931421932

CHLDFCVRCHLDFCVR1CHLDFCVR2

Lower Deadfront Cover with Duplex, Duplex, Duplex Receptacle Opening

Lower Deadfront Cover with Rectangle Receptacle OpeningLower Deadfront Cover with Rectangle, Rectangle

Receptacle Opening

421933421934

421935

CHLDFCVR3CHLDFCVR4

CHLDFCVR5

Lower Deadfront Cover with Rectangle, Rectangle, Rectangle Receptacle Opening

Lower Deadfront Cover with Duplex, Rectangle Receptacle OpeningLower Deadfront Cover with Duplex, Rectangle, Duplex

Receptacle Opening

421936421937

421938

CHLDFCVR6CHLDFCVR7

CHLDFCVR8

Lower Deadfront Cover with Rectangle, Rectangle, Duplex Receptacle Opening

Lower Deadfront Cover with Round Receptacle OpeningLower Deadfront Cover with Round, Round Receptacle Opening

421939421940422128

CHLDFCVR9CHLDFCVR10CHLDFCVR11

Lower Deadfront Cover with Round, Duplex Receptacle OpeningLower Deadfront Cover with Round, Duplex, Duplex

Receptacle OpeningLower Deadfront Cover with Round, Duplex, Round

Receptacle Opening

422129

421942

421943

CHLDFCVR12

CHLDFCVR13

CHLDFCVR14

Lower Deadfront Cover with Round, Rectangle Receptacle OpeningLower Deadfront Cover with Round, Rectangle, Rectangle

Receptacle OpeningLower Deadfront Cover with Round, Rectangle, Round

Receptacle Opening

421944

421945

421946

CHLDFCVR15

CHLDFCVR16

CHLDFCVR17

Lower Deadfront Cover with Round, Rectangle, Duplex Receptacle Opening

Upper Deadfront Cover with Six Breaker TwistoutsUpper Deadfront Cover with Provisions for Lighted Option

422079421947421948

CHLDFCVR18CHUDFCVRCHUDFCVRL

Power Head Outer CoverPower Head Outer Cover with Lens

421949421950

CHOUTCVRCHOUTCVRL

6-Hole Neutral Assembly with 2/0 Lug7-Hole Neutral Assembly with 2/0 Lug5-Hole Ground Bar Kit10-Hole Ground Bar Kit

421951422180309906401456

CHNEUTCHNEUT1GBK5GBK10

Replacement Meter Cover — Ring Type Replacement Meter Cover — Ringless �Replacement Meter Cover — Ringless �Replacement Meter Cover — Ringless �

483847483848612729641914

CHPOPRMCCHPOPRLMCCHPOPRLMCNCHPOPRLMCN2

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD

Underground Pedestal Extension

Pad-Mount Bracket

DS Hub

Cable TV/TelephoneBracket

Neutral Assemblies

Power Head Outer Cover with Lens

Power Head Outer Cover

Inner Lens

Meter Socket

Loop Feed Lug Assembly

Lower Deadfront Cover

Upper Deadfront Cover

Circuit Breaker(BR/GFCB)

Bonding Strap and Mounting Hardware

February 2007

6-16

For more information visit: www.eaton.com CA08101001E

Power Outlet Panels

6

Product Selection

Mobile Home PanelsThe versatile Cutler-Hammer Mobile Home Panels have a user-friendly design that allows for a faster, cleaner installation — letting you move on to your next job sooner.

100 and 200 ampere panels come complete with the main breaker and a 4/8 or 8/16 interior, respectively. The 200 ampere units are designed about 5 inches wider than other manufacturer’s panels to ensure plenty of room for wire bending and an easier wiring job.

Receptacle Deadfront Kits200 ampere units include a new door. Optional receptacle deadfront kits can supply power for a variety of applica-tions including:

■ Visiting RVs.■ Pool filters.■ Weed whackers.■ Air compressors.■ Anything else that requires power

(receptacles and breakers supplied by contractor).

Fastenerless Socket Design■ Makes failure a non-issue.■ No socket connections that

overheat.

Pedestal Unit■ Convenient and sturdy ground

mounting.■ Loop feed feature allows several

units to be connected in series.

Easier, Better and Faster Installation■ More wire bending and viewing

room.■ Additional circuits mean more

flexibility.

Table 6-10. Mobile Home Panels �

� Pedestal Extension included with Mobile Home Panels.

Amperes Security Interior Main BranchBreakers

Mounting Receptacles UPC Number78211

CatalogNumber

PriceU.S. $

100100100100

RingRingRinglessRingless

4/84/84/84/8

BR2100BR2100BR2100BR2100

BRBRBRBR

PedestalBack-to-BackPedestalBack-to-Back

NoneNoneNoneNone

498168 9498169 6498170 2498171 9

MHM100PMHM100BMHR100PMHR100B

150150150150

RingRingRinglessRingless

8/168/168/168/16

BWH2150BWH2150BWH2150BWH2150

BRBRBRBR

PedestalBack-to-BackPedestalBack-to-Back

NoneNoneNoneNone

617535 2617534 5616475 2616474 5

MHM150PMHM150BMHR150PMHR150B

200200200200

RingRingRinglessRingless

8/168/168/168/16

BWH2200BWH2200BWH2200BWH2200

BRBRBRBR

PedestalBack-to-BackPedestalBack-to-Back

NoneNoneNoneNone

498172 6498173 3498174 0498175 7

MHM200PMHM200BMHR200PMHR200B

200 Ringless 8/16 BWH2200 BR Pedestal Qty 1 14-50RQty 2 TT-30R

498176 4 MHM200P1N4N4N

February 2007

CA08101001E For more information visit: www.eaton.com

6-17Power Outlet Panels

6

Product Selection

Product Selection

Figure 6-11. Mobile Home Panel — Ringless Security — Pedestal Mounting

Figure 6-12. Mobile Home Panel — Ringless Security — Back-to-Back Mounting

Grade Level

5.31

27.87(708.0)28.01

(711.5)23.69

(601.8)

50.08(1272.1)

RinglessSocket

Rated 200 AContinuous

200A57.81

(1468.3)

Sealin

1-1/4, 1-1/2,2, 2-1/2

(31.8, 38.1,50.8, 63.5)Knockout

1, 1-1/4, 1-1/2, 2(25.4, 31.8, 38.1, 50.8)

Knockout

5/16 (7.9)Diameter KO

OppositeSide Only

43.20(1097.4)

28.70(729.0)

1.212.00

(50.8)

24.65(626.1)

Optional DirectFeed Kit

Shown Installed(Cover Not Shown)

1/2, 3/4,1(12.7, 19.1, 25.4)KO (2 Required)

1, 1-1/4, 1-1/2, 2(25.4, 31.8, 38.1,50.8) KO

1/2, 3/4, 1, 1-1/4,1-1/2 (12.7, 19.1,25.4, 31.8, 38.1) KOSealing Provision

SealingProvision

DoorNotShown

12.09(307.2) 10

27.87(708.0)

22.01(711.5) 18.69

(474.6)

25.00(635.0)

Front View

Feed Kit Shown Installed

(Cover NotShown)

200AMain

SealingProvision

1-1/4, 1-1/2,

(31.8, 38.1,50.8, 63.5)Knockout

5/16 (7.9) Diameter

Side Only

DiameterKO

Side Only1,1-1/4,1-1/2, 2

Grade Level

Door NotShown

23.69(601.8)

50.08(1272.1)

57.81(1468.3)

(1097.4)

28.70(729.0)

1.212.00

14.45

Bottom Endwall Direct Feed Kit

1/2, 3/4, 1 (12.7,19.1, 25.4) KO(2) Required

1/2, 3/4, 1, 1-1/4, 1-1/2(12.7, 19.1, 25.4, 31.8, 38.1) KO

1, 1-1/4, 1-1/2, 2(25.4, 31.8, 38.1, 50.8) KO

Bottom Endwall Back Unit

1-1/2, 2, 2-1/2, 3 (38.1, 50.8, 63.5, 76.2) KO

KO (3) Required

1/2 (12.7) KO(3) Required

3/4, 1 (19.1, 25.4) KO

1-1/4, 1-1/2, 2, 2-1/2(31.8, 38.1, 50.8, 63.5) KO(2) Required

KO (2) Required

RinglessSocket

Rated 200 AContinuous

Back View

February 2007

6-18

For more information visit: www.eaton.com CA08101001E

Power Outlet Panels

6

Product Selection

Figure 6-13. Mobile Home Panel — Ring Security — Pedestal Mounting

Figure 6-14. Mobile Home Panel — Ring Security — Back-to-Back Mounting

ON

OFFO

N

OFF

Ring Type SocketRated 200 A Continuous

200A MainBreaker

DoorNotShown

5/16 (7.9) Diameter

KOOpposite

Side Only

1-1/4,1-1/2, 2,

2-1/2(31.8, 38.1,

Knockout

SealingProvision

24.64(626.0)

Optional Direct Feed KitShown Installed

(Cover Not Shown)

28.01(711.5)

1, 1-1/4,1-1/2, 2

(25.4,

50.8) KO

1/2, 3/4, 1 (12.7, 19.1, 25.4) KO(2 Required)

Direct Feed Kit

1/2, 3/4, 1, 1-1/4,1-1/2 (12.7, 19.1,25.4, 31.8, 38.1) KO

1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO

Grade Level

27.87(708.0)

23.69(601.8)

50.08(1272.1)

57.81(1468.3)

28.70(729.0)

1.21(30.7)

2.00(50.8)

5.56(141.3) 5.31

(134.8)

43.20(1097.4)

14.45

Grade Level

1-1/4,1-1/2, 2,

2-1/2(31.8,

38.1, 50.8,63.5)

Knockout

Sealing Provision

5/16 (7.9)Diameter KO

Back View Front View

1-1/4, 1-1/2, 2, 2-1/2

KO (2) Required

Bottom EndwallBack Unit

Direct Feed Kit

1/2, 3/4, 119.1, 25.4) K(2) Required

1/2, 3/4, 1, 1-1/4,1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO

1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO

, 2, 2-1/2, 3 (38.1,50.8, 63.5, 76.2) KO

3/4, 1 (19.1, 25.4) KO

Feed KitShown Installed

(Cover NotShown)

200AMain

Breaker

DoorNotShown

23.69(601.8)

50.0(1272

57.81(1468.3)

43.20(1097.4)

28.70(729.0)

11.25(285.8) 10 75 14.45

(367.0) Ring Type SocketRated 200 A Continuous

27.87(708.0)

18.69(474.6)

25.00(635.0)

22.01(711.5)

5/16 (7.9) Diameter 1/2 (12.7) KO(3) Required

KO (2) Required

February 2007

CA08101001E For more information visit: www.eaton.com

6-19Power Outlet Panels

6

Product Selection

Mobile Home Panel Deadfronts for 200 Ampere Units �

Figure 6-15. Available Receptacle Deadfront Kits — Receptacles and Breakers Not Included� For 100 ampere units, the accessory Catalog Number would be MHD1___. For example, to order

a deadfront to accept one 30 ampere receptacle (round) in a 100 ampere device, the Catalog Number would be MHD1X.

Cutler-Hammer is am federally registered trademark of Eaton Corporation. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, Mass. NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. UL is a federally registered trademark of Underwriters Laboratories Inc.

February 2007

6-20

For more information visit: www.eaton.com CA08101001E

Power Outlet Panels

6

This page intentionally left blank.