    2. Construction site any premises

    (a) erection, construction, alteration, repair

    or maintenance of buildings, structures orroads;

    (b) the breaking up, opening or boring underany road or adjacent land in connection with

    the construction, inspection, maintenance orremoval of works;

    (c) piling, demolition or dredging works; or

    (d) any other work of engineering

    construction.

  • 8/12/2019 Construction Noise

    2/17

    Permissible noise level

    After 1st Oct 2007, maximum permissible noiselevels set out in second schedule.

    Noise measurement taken at one meter awayfrom the outside of any affected building.

  • 8/12/2019 Construction Noise

    3/17

    MAXIMUM PERMISSIBLE NOISE LEVELS

    Types of affected buildings Maximum permissible noise

    level for construction sites

    (reckoned as equivalent over

    12 hours in dB(A))

    7 am to 7 pm 7 pm to 7 am

    (a) Hospitals, schools 60 50

    (b) Residential buildings located 75 -

    less than 150 m from construction

    Site

    (c) Buildings (other than above) 75 65

  • 8/12/2019 Construction Noise

    4/17

  • 8/12/2019 Construction Noise

    5/17

    Maximum permissible levels Leq, 5 min

    Types of buildings Max permissible levels Leq, 5 min

    7 am to 7 pm 7 pm to 10 pm 10 pm to 7 am

    (a) Hospitals, schools 75 55 55

    (b) Residential buildings

    less than 150 m(i) On Mondays to Saturdays 90 70 55

    (ii) On Sundays and PH 75 55 55

  • 8/12/2019 Construction Noise

    6/17

    PROHIBITED PERIODS

    1. From 190 pm every Sat to 7 am on the following Monday.

    2. From 10 pm on eve of PH to 7 am on the day following PH

  • 8/12/2019 Construction Noise

    7/17

    Construction Site

  • 8/12/2019 Construction Noise

    8/17

    Construction Site

  • 8/12/2019 Construction Noise

    9/17

  • 8/12/2019 Construction Noise

    10/17

    CP 49 : 1998 CODE OF PRACTICE FOR

    NOISE CONTROL ON CONSTRUCTIONAND DEMOLITION SITES

  • 8/12/2019 Construction Noise

    11/17

  • 8/12/2019 Construction Noise

    12/17

    Free Field

  • 8/12/2019 Construction Noise

    13/17

    Reflection from wall

    3 dB(A) higher

  • 8/12/2019 Construction Noise

    14/17

    Reflection from each wall

    6 dB(A) higher

  • 8/12/2019 Construction Noise

    15/17

    Source outside line of sight

  • 8/12/2019 Construction Noise

    16/17

    B.5.2 Allowance for reflection of sound at a

    building faade

    When the sound level at a building faade is to

    be estimated, an additional of 3 dB(A) should

    be made to the value calculated for an open

    space to allow for the effect of reflection ofsound from the faade. In situation where

    multiple reflections occur immediately outside

    a building due to several surrounding walls,

    sound levels may be increased even further.

  • 8/12/2019 Construction Noise

    17/17

    C.2 Control of noise from construction sites

    The measurement of ambient noise level must becarried out either prior to the start of the project, or if

    the project has already commenced, during periods

    when there is no noise producing activity being carried

    out on the site in question.

    The ambient noise levels should be measured over a

    chosen period of time, say 12 h (from 0700 hrs to 1900

    hrs or from 1900 hrs to 0700 hrs). The ambient noise

    levels so obtained will give an indication of the current

    noise status of the site prior to any constructionactivity.