1 (15) EN.33.C.94.1901 Technical data Article no. 623 12 24 Height 601 mm Width 546 mm Depth 180 mm Weight 28 kg Volume capacity 2 liter Design pressure 2,5 bar Test pressure 3,3 bar Safety valve 2,5 bar Expansion vessel volume 12 liter Design temperature 100 °C Output 6,3 - 11 kW Voltage 400V AC 3N~, 50 Hz Current 16,9 A Fuses 3 x 20 A Enclosure category IP 21 Power circulation pump 2-34 W Condensing boiler No Low-temperature boiler No B1 boiler No Cogeneration space heater No Combination heater No Nominal output power P rated 11 kW Usable output power P 4 11,0 kW Energy class D Seasonal average efficiency for space heating Boiler η s 37% Boiler with UTK 39% Additional power consumption In standby mode P SB 0,003 kW Construction LK Electric Boiler -11, is a wall mountable and is primarily designed for low-temperature heating systems, e.g. under floor heating. The boiler has the following features: • Expansion vessel • Safety valve • Automatic air-bleeding valve • Filling/drainage valve • Overflow valve (safety valve device to pre- vent overheating; if low flow rates it activa- tes maximum safe temperature protection). • Circulation pump, Grundfos UPM3 Auto L 15-50 • Enclosure concealing pipe connections LK Electric Boiler -11, is for space heating only, not hot (washing) water. Operation / Requirements • Electronic temperature regulation with seven settings from 1,6 kW to 11 kW. The boiler is equipped with outside tem- perature (weather) compensation, for auto- matic control of internal temperature and power output. Other functions included in the electronic controls: • User selection of heating output at gradients of 4-7. • Overheating (maximum safe temperature) safety function, this immediately shuts down the boiler. • Boiler temperature sensor and monitor. • Status indication - indicating operational status or malfunction. • Input for external switching, e.g. room ther- mostat. • Input for remote control, incl. frost protec- tion 10–20 °C. • Circulation pump relay. Sized for Kitchen Cabinets LK Electric Boiler -11, can be wall hung or hidden in a cupboard. Its dimensions (WxHxD) are 546 x 601 x 180 mm, so it can be mounted in most kitchen cabinets. LK Electric Boiler 11-n Assembly instructions | LK Electric Boiler 11-n

Upload: duongdang

Post on 14-Aug-2019

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

1 (15)

EN.33.C.94.1901

Technical dataArticle no. 623 12 24Height 601 mm Width 546 mm Depth 180 mm Weight 28 kg Volume capacity 2 liter Design pressure 2,5 bar Test pressure 3,3 bar Safety valve 2,5 bar Expansion vessel volume 12 liter Design temperature 100 °C Output 6,3 - 11 kW Voltage 400V AC 3N~, 50 Hz Current 16,9 A Fuses 3 x 20 A Enclosure category IP 21 Power circulation pump 2-34 WCondensing boiler NoLow-temperature boiler NoB1 boiler NoCogeneration space heater NoCombination heater NoNominal output power Prated 11 kWUsable output power P4 11,0 kWEnergy class DSeasonal average efficiency for space heating

Boiler ηs 37% Boiler with UTK 39%

Additional power consumption In standby mode PSB 0,003 kW

ConstructionLK Electric Boiler -11, is a wall mountable and is primarily designed for low-temperature heating systems, e.g. under floor heating.

The boiler has the following features:• Expansion vessel• Safety valve• Automatic air-bleeding valve• Filling/drainage valve• Overflow valve (safety valve device to pre-

vent overheating; if low flow rates it activa-tes maximum safe temperature protection).

• Circulation pump, Grundfos UPM3 Auto L 15-50

• Enclosure concealing pipe connections

LK Electric Boiler -11, is for space heating only, not hot (washing) water.

Operation / Requirements• Electronic temperature regulation with seven

settings from 1,6 kW to 11 kW. The boiler is equipped with outside tem-perature (weather) compensation, for auto-matic control of internal temperature and power output.

Other functions included in the electronic controls:

• User selection of heating output at gradients of 4-7.

• Overheating (maximum safe temperature) safety function, this immediately shuts down the boiler.

• Boiler temperature sensor and monitor.• Status indication - indicating operational

status or malfunction.• Input for external switching, e.g. room ther-

mostat.• Input for remote control, incl. frost protec-

tion 10–20 °C.• Circulation pump relay.

Sized for Kitchen CabinetsLK Electric Boiler -11, can be wall hung or hidden in a cupboard.

Its dimensions (WxHxD) are 546 x 601 x 180 mm, so it can be mounted in most kitchen cabinets.

LK Electric Boiler 11-n

Assembly instructions | LK Electric Boiler 11-n

Page 2: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

2 (15)

EN.33.C.94.1901

Assembly instructions | LK Electric Boiler 11-n

14. Return connector ¾” female15. Cable screwed unions16. Knock-out opening, to be used when con-

nection cables come out of the wall17. Overheating (maximum safe temperature)

protection18. Main switch19. LED x 420. Circuit board OX 7E21. Circuit board OX 7E UTK22. Pressure gauge/thermometer23. Cover for electric cartridge24. Shrouds for electrical connections on elec-

tric cartridge25. Skirt concealing pipe connections

Standby heat loss Pstby 0,022 kW

13 1415

12

23

1718

22

3

19

25

1 2

54

87

6

9 16

18 20

1711

1413

24

1222

21

10

Benämning

1. Safety valve, 2.5 bar, ¾” female

2. Automatic air-bleeding valve, ⅜” male3. Control panel4. Boiler tank, incl. electric cartridge5. Expansion vessel, 12 litres, pre-pressure 1.5

bar6. Nipple for controlling/filling expansion

vessel with air7. Installation points for temperature and ther-

mometer sensors8. Connector for pressure gauge9. Circulation pump, 1” male10. Overflow valve11. Filling/drainage valve, ½” male 12. Discharge pipe for safety valve13. Flow connector ¾” female

4

5

67

8

9

1011

12 13 1422

16

1718

21

Page 3: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

3 (15)

EN.33.C.94.1901

Assembly instructions | LK Electric Boiler 11-n

Where the pressure or temperature is reduced, the vessel will be able to handle larger heating system volumes.

Glycol anti-freeze mixtures reduce the capacity of the expansion vessel. Contact LK for advice.

Safety valveThe safety valve opens at 2.5 bar. A drainpipe should be fitted and connected to a waste outlet.

Circulation pumpDelivery setting: Constant pressure curve 1. If parts of the heating system do not get hot, this can be changed to Constant pressure curve 2. Selecting a higher curve increases energy con-sumption and operating costs.

Push but-ton

LEDs

In operating mode, the first LED lights up green, and between one and four LEDs light up yellow. The yellow LEDs indicate the operating capacity of the pump.

0 - 25 %

25 - 50 %

50 - 75 %

75 - 100 %

Pressing the button displays the pump setting for 2 sec before the pump returns to normal display.

Pipe installationThe electric boiler is mounted indoors, with the pipe connections at the bottom.

Current building standards and plumbing regu-lations must be followed during installation.

The space between the floor and the boiler base must be at least 600 mm to allow electric cartrid-ges to be replaced.

The connection of the boiler and the heating sys-tem must be in accordance with the system dia-gram below.

Ambient room temperature must not exceed 30 ºC.

The boiler is designed for use in sealed systems. Hard, (calcium-rich) water is not suitable for the boiler. “Hard” water calcium deposits may da-mage the boiler; in very hard water areas, water softeners may be required, check the pH value is not low – pH7 is neutral. Note: high Chlorine water treatment levels may damage parts of the boiler, particularly the heating cartridges.

When connecting external pipe work to the boi-ler, care must be taken not to bend or damage the boilers internal pipe work.

Isolation valves must be mounted between the electric boiler and the heating system to simplify filling and draining.

All pipe connectors are ¾” female.

Expansion vesselThe vessels capacity is 12 litres and is pre-pres-surised at 1.5 bar, which corresponds to a static height of 15 metres. At 1.5 bar, the expansion ves-sel can handle heating system volume of 200 lit-res, with a boiler temperature of 60 °C.

When supplied, the expansion vessel is pres-surised at 1.5 bar. This may require adjustment during installation.

Page 4: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

4 (15)

EN.33.C.94.1901

Assembly instructions | LK Electric Boiler 11-n

Pump capacity

0

1

2

3

4

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Q [m³/h]

5

[m]H

0

10

20

30

40

50

[kPa]p

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Q [l/s]

0

5

10

15

20

0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 Q [m³/h]

25

30

35[W]P1

12

34 5

6

78 9

10

1112

1. Safety valve2. Air-bleeding valve3. Outside temperature sensor4. Boiler temperature sensor/sensor for flow

temperature5. Expansion vessel6. Circulation pump7. Boiler tank, incl. electric cartridge8. Overflow valve9. Filling/drainage valve for boiler 10. Isolation valves11. Filling & drain valves12. Under floor heating

PROP. PRESSURE: CURVE 1

PROP. PRESSURE: CURVE 2

PROP. PRESSURE: CURVE 3

CONST. PRESSURE: CURVE 1

CONST. PRESSURE: CURVE 2

CONST. PRESSURE: CURVE 3

CONST. CURVE: KURVA 1

CONST. CURVE: KURVA 2

CONST. CURVE: KURVA 3

CONST. CURVE: KURVA 4

If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be selected by turning the button. When the button has been released for 10 sec, the pump returns to operat-ing mode, the LEDs stop flashing and the selected curve becomes active.

A lit red LED indicates an alarm or warning.

Indication Fault Status Measure

Red +

fourth yellow

Motor blocked

Pump tries to restart at 1.5 sec intervals

Release motor/impeller or wait

Red +

third yel-low

Low volt-age

Warning only, pump continues to operate

Check volt-age to pump

Red +

second yellow

Electrical fault

Pump stopped

Check volt-age/replace pump

A button lock prevents accidental adjustments to the pump settings. The button can be locked/un-locked by depressing the button for 10 seconds. After 10 seconds, all the LEDs will flash quickly to indicate that the lock is locked/unlocked.

Page 5: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

5 (15)

EN.33.C.94.1901

Assembly instructions | LK Electric Boiler 11-n

The boiler’s electrical connection requires a cable measuring 5 x 4 mm2 Cu, with fusing at maxi-mum 3 x 20 A.

Outside temperature sensor

The sensor is mounted in the north or north-west facing wall, below the eaves and away from win-dows or doors.The sensor is attached to terminals 4 and 5 in the terminal bloc. The wires must be at least of 0.75 mm2 and they must not be placed near power cable, as induction currents can affect the signal.

Loading relay / transformers

Main fuse

Transformers

Group centre

4

Overflow valveThe (under floor) heating system should not ex-ceed a flow pressure of 20 kPa.If all of the heating system valves close, circula-tion ceases in the boiler and there is a risk of over heating, then the “maximum safe temperature” protection is tripped. To avoid this, an overflow valve is built in, ensuring flow though the boiler. If the pressure resistance of the heating system ex-ceeds the overpressure, flow problems can arise in the heating system.

FillingWhen filling the heating system, the safety valve must be kept open until water flows from the overflow pipe. Next, close the safety valve and fill with water and pressurise to approx. 2 bar.

Air-bleedingBleed the system of air via the air-bleed valves on the boiler and heating (system) manifolds. The air-bleed valves have a protective cap, these need loosening slightly to allow air passage.

To ensure air-bleed valves work properly, the sys-tem pressure must not fall below 1.5 bar.

Bleeding the pump is done via its air-bleed screw. Loosen the screw and hold a piece of cloth over the opening as a little water may spurt out.

Electrical installationElectrical installation work must be carried out by a qualified electrician.

The boiler and the heating system must be filled and bled of all air, before the boiler is powered up.

Page 6: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

6 (15)

EN.33.C.94.1901

Assembly instructions | LK Electric Boiler 11-n

Switching off

1234

6

7 Switch 1 in position OFF

The output can be switched off by an external de-energised contact, e.g. room thermostat. Open contact causes stepped reduction in output. Con-nection is made to the base of the circuit board. The existing link between terminals 2–3 is remo-ved.

Output control with 0-10V signal

1234GND 0-10Vdc

6

The boiler’s output control is arranged via 0 – 10V DC signal, which corresponds to 0% - 100% of the installed capacity, see below. Connection is made to the base of the circuit board. The existing link between terminals 2 – 3 is removed.

0-10V variable output

1234

GND 0-10V

6

Assisted by transformers, the loading relay mea-sures loading affecting the main fuses. Fuse size, 16 - 50 A, situated on the circuit board.

The transformers are located on the wire from the fuses and must be protected. Connection is made to the base of the circuit board using high-current-insulated cable, minimum 0.75 mm2. The earth (grounding) is connected using terminal 4.

The transformers do not need to be connected if this function is not intended to be used.

Remote control / Switching offOne of the inputs on the circuit board has a dif-ferent function depending on switch SW 4/1. The functions cannot be used simultaneously.

1. Remote control, which depends on the in-put status, switches between normal tempe-rature mode and low temperature mode.

2. Switching off the entire boiler output.

Remote control

1234

Switch 1 in position ON

76

8

Example; this function can be used to maintain a low temperature for frost protection when the house is not occupied. By connecting the system to phone-based control, the temperature can be varied by making a phone call. The contact fun-ction in the control unit must be de-energized.

Open between 2 – 3, temperature corresponds to the setting shown in item 8.

Shut between 2 – 3, ordinary temperature set-ting.

Page 7: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

7 (15)

EN.33.C.94.1901

Assembly instructions | LK Electric Boiler 11-n

The boiler’s output can be altered by using the 0 – 10V DC signal, which corresponds to 0%–100% of the boilers capacity as installed: see below. Con-nection is implemented to the base of the circuit board. The jumper between brackets 2 - 3 is not involved in this function.

Installed capacityThe selected number of levels corresponds to the installed capacity.

Example:The selection has been done so that the boiler’s maximum allowed output is 7.9 kW, five levels selected. Installed capacity corresponds to 7.9 kW. When applying voltage-based control, 0 – 10V DC, 10V is needed for connecting five levels. The same applies to the voltage signal for con-nected capacity.

Delay in connection following a voltage non-responseIn accordance with the regulations, the electric heating capacity in excess of 6 kW is delayed fol-lowing reconnection after a voltage non-respon-ses of more than three minutes. Once the voltage is back on, no more than three output levels are connected; the remaining levels are delayed by approx. 2 hours.

13

The connection delays can be temporarily by-passed in order to monitor the functioning of the boiler. Press down and keep pressed down the SNABB (Quick) button, no. 13, until the illumina-ted text “Status” is shown.

Page 8: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

8 (15)

EN.33.C.94.1901

Assembly instructions | LK Electric Boiler 11-n

10. Indicator for Output Group 2: 3.1 kW.11. Indicator for Output Group 3: 6.3 kW.12. Status indication: See item Control panel.13. Button: For temporary switching off for 2h

time locks, and for instant output adjust-ment.

14. Switch: See item “Installation” below. 15. Circuit board: Outside temperature com-

pensator.16. Main switch.17. Overheating (maximum safe temperature)

protection.18. Circulation pump.19. Electric cartridge, 3 x 1.6 kW, for Output

Groups 1 and 2 as well as 3 x 2.1 kW for Output Group 3.

Wiring diagram

1

2

34

5

6

7

89 10 11 12

13

14

18

15

19

19

17

16

BLACK

BLACK

BLACK

BLACK

WHITE

WHITE

WHITE

WHITE

WHITE

WHITE

BROWN

BROWN

BROWNBROWN

BROWN 2

BROWN 3

BROWN 11

BROWN 10

WHITE 6

WHITE 1

WHITE 7

WHITE 12

BLACK 8BLACK 9

BLACK 5

BLACK 4

1. Terminal bloc.2. Outside temperature sensor.3. Power supply connection: 5 x 4 mm2, fused

3 x 20A.4. Transformers for loading relay.5. Boiler temperature sensor/sensor for the

temperature of the outgoing water.6. Connection for remote control: External

blocking and 0–10V signals.7. Switch: See item “Settings” below.8. Temperature setting via remote control.9. Indicator for Output Group 1: 1.6 kW.

Page 9: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

9 (15)

EN.33.C.94.1901

Assembly instructions | LK Electric Boiler 11-n

Settings

ON

OFF

ON

OFF

OFF

OFF

ON

OFFOFF

OFF

ON

ONON

OFF

OFFOFF

16A

20A

25A

35A

50A

OFF

OFFOFF

OFFON

ONOFF

ONON

ON

OFF

7-levels

6-levels

5-levels

4-levels

Main fuses’ rating size.Supply setting 20A.

Circulation pump’s drive mode:

continuoussupply setting

summertime drive mode

Maximum number of capacity levels for the boiler.Each level corresponds to 1.6 kW. See following table.Supply setting 7 levels: 11 kW.

Fuse

Fuse

Fuse

Fuse

Fuse

Output level

Output Cur-rent L1

Cur-rent L2

Cur-rent L3

Output group

kW A A A1; 15% 1,6 3,9 3,9 0 1 2; 30% 3,1 3,9 3,9 7,8 2 3; 45% 4,7 6,8 6,8 6,8 1 + 2 4; 55% 6,3 9,1 9,1 9,1 3 5; 70% 7,9 13 13 9,1 1 + 3 6; 85% 9,4 13 13 16,9 2 + 3 7; 100%

11 15,9 15,9 15,9 1 + 2 + 3

Remote control: Switch 1 in position ON, see item Remote control.

ON OFF

Remote controlSwitch 1 in position ON

7

Temperature setting in accordance with item 8, applies when inlet is open. When inlet is shut, or-dinary temperature setting applies.

Temperature setting when regulated via remote control

8

Switching off: Switch 1 in position OFF, see item Switching off.

ON OFF

Off switch 1in position OFF

7

Page 10: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

10 (15)

EN.33.C.94.1901

Assembly instructions | LK Electric Boiler 11-n

Control panel / Heating settingsFront panel

1

4

2

3

5

6

10987

1. Temperature and manometer: Show boiler temperature / temperature of the outgoing water as well as heating system’s pressure.

2. Main switch: Switches on and off all voltage to boiler. 3. Resetting of overheating (push hard to reset). 4. Operation indication: Lights up when boiler is switched on. 5. Selector switch, Program selection:

standby position: , recommended before turning main switch to position O, if the purpose is to switch off the boiler. Heating system needs to be filled with water. The circulation pump is set in motion and protection against freezing is activated when the boiler temperature falls below 10 °C. normal operation: , see item 14.

alternative operation:, see item 13.

6. Adjusting: The heat graph can be moved in parallel ±10 °C. When calculated in degrees, the room temperature chan-ges by approximately half as much as the temperature of the outgoing water. If you need a major change in tempera-ture, select another heating graph, see item 14.

7. Indicator for Output Group 1. 8. Indicator for Output Group 2. 9. Indicator for Output Group 3. 10. Status indicator:

Page 11: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

11 (15)

EN.33.C.94.1901

Assembly instructions | LK Electric Boiler 11-n

Steady illumination Normal operation One long + one short flash

Delay in connection after a power outage limits output adjustment.

One long + two short flashes

Loading relay, room thermostat or some other external control device limits output adjustment.

One long + three short flashes

A. Overheating (maximum safe) temperatureConnected output becomes disconnected immediately when the temperature exceeds set point value by more than 5 °C. Reconnection takes place when temperature falls below overheating (maximum safe) temperature.

B. Malfunction at boiler temperature sensorOutput is not switched on despite temperature being below set point value. Replace sensor. Acknow-ledge alarm by keeping boiler switched off for 10 seconds, turn main switch to position 0.

One long + four short flashes

Remote control activated.

Rapid flashes By-passing of the connection delay: SNABB (Quick) button, item 13 in wiring diagram, keep button pressed down until status indicator is illuminated steadily.

Loss of pressure No voltage or selector in position:

UTK panel

15 1413

11

12

The panel is viewable once the boiler’s top support has been taken off and the automation cabinet’s control panel has been folded out.

11. Temperature diagram: This shows the dependence of the temperature of the flow water on the selected graph and the outside temperature.

12. Maximum temperature: Highest allowed temperature, 60 °C, (not adjustable). 13. Alternative temperature: The temperature of the outgoing water can be increased/decreased ±15 °C in relation to the

normal temperature. Adjustments are implemented by using the selector switch, see item 5 above. , 14. Water temperature flow rates used as the output values available on the graph are used in the floor heating calcula-

tions. If these values are not available, use graph 1 for under floor heating systems laid over a timber sub-floors. If the loops of tubing are embedded in concrete, use a lower graph, e.g. 0.75.

15. Minimum temperature: Lowest allowed temperature of flow water. If there is no particular requirement, do the installa-tion for a temperature of 20 °C.

Supply settings:Min. temp. 20 ºC Graph 1 Alternative temp. -5 ºC Max temp. 60 ºC

Page 12: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

12 (15)

EN.33.C.94.1901

Operation and maintenanceWith installation completed, check with the instal-ler that the appliance is fully operational. Ask the installer that did the installation work to show you the controls and functions so that you will know how the system works and how to look after it.

Check the following:• That the boiler and the heating system are

filled with water and any air in them has been evacuated.

• That the air-vent is open to allow air to come out.

• That all pipe connectors are tight, no leaks.• That the safety valve works; water should

come out of the overflow pipe when this valve is operated.

Switching on• Switch on the boiler by turning the main

switch to position I, which should result in the boiler’s operation and status indicator to be illuminated.

• Set the desired temperature, see item Con-trol panel. The output level must be ad-justed if there is a need for heat. You can shorten the output adjustment time by keeping the “Snabb” (Quick) button press-sed down until the desired number of levels have been connected.

• Circulation pump starts up when Output Level 1 is selected.

Water pressure in the systemCheck regularly that the system’s water pressure is sufficient. The pressure gauge reading should be 1.5 – 2.0 bar.

If the system’s pressure drops and does not rise, fill it up with water until the pressure gauge shows approx. 2 bar. Repeated problems in main-taining the pressure may be an indication of a leak in the system.

Water volume varies according to its temperature and this affects the pressure in the system. The higher the temperature, the greater the volume

and pressure. The expansion vessel accounts for some of the volume variation. Do not add water unless necessary.

Expansion vesselThe pre-pressure needs to be checked at intervals of a few years by a competent installer.

Safety valveThe valve opens at 2.5 bar and its closing pres-sure is slightly less. This valve needs to be ope-rated at regular intervals, about every 3 months. Do this by turning the valve handle until water comes out of the overflow pipe. Contact a compe-tent installer if the safety valves open repeatedly.

Air-bleedingSome air may remain in the heating system after installation, which is why air-bleeding should be done a few times afterwards on the under floor heating system/radiator system.

Check the pressure after air-bleeding and whene-ver you fill up the system.

Air-bleeding valve

Isolation valve

The electric boiler is equipped with an automatic air-bleed valve which facilitates air-bleeding in connection with startup. The bleed valve should be closed approx. 1 month after the heating sys-tem has been switched on.

Assembly instructions | LK Electric Boiler 11-n

Page 13: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

13 (15)

EN.33.C.94.1901

Temperature settingSee item Control panel.

Delay in connection following a voltage interup-tionActive delay is indicated by the flashing of the status indicator, see item 10, and Control panel.

Switched off main switch or triggered overhea-ting (maximum safe temperature) protection, have the same result as a voltage outage.

Loading relayThe loading relay limits the boiler output when other appliances (e.g. washing machine, cooker) are in operation at the same time as the boiler. Then, as soon as the situation allows it, the se-lected output level is automatically back on. The situation where the loading relay limits the boiler output is indicated by the flashing of the status indicator, see item 10 and Control panel.

Room thermostat / External switchingIf a room thermostat is connected to the boiler, it is to be used in limiting the maximum room tem-perature. Situation where the room thermostat / external swithing are limiting the boiler output, is indicated by the flashing of the status indicator, see item 10 and Control panel.

Overheating (maximum safe temperature) protection

The electric boiler’s overheating (maximum safe temperature) protection is triggered at approx. 95 °C. Resetting is possible when the tempera-ture has dropped to below 80 °C. Press down the Overheating protection button using a small object (press button hard), see item 3, Control panel.

Measures to be taken when there is a risk of

freezingWhenever there is a risk of freezing, do not shut down any part of the heating system as fracture may occur due to freezing. Should some part of the heating system show signs of having frozen, call a plumber to assess the situation and damage.

If the heating system needs to be shut down, it must be drained or alternatively the system needs to be filled with a mixture of water and glycol.

DrainingBefore draining the system, cut of the power supply to the boiler in order to avoid damaging the electric cartridge.

Automatic air-bleeding valve

Safety valve

Overflow pipe

Air valve for expansion vessel to facilitate control and filling with air.

Circulation pump

Assembly instructions | LK Electric Boiler 11-n

Page 14: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

14 (15)

EN.33.C.94.1901

TroubleshootingMeasures requiring tools should be carried out by a qualified installer. Begin troubleshooting by viewing the status indicators, see item 10, and Control panel.

Fault Possible cause Remedial messureOperation and status indicator not illumina-ted, no heat.

Electric boiler without power. Check main fuses. Main switch turned off. Turn main switch to position 1. Connection delay switches off

output if boiler without power longer than 3 minutes. Operation indicator illuminated and status indicator not illumina-ted, no heat.

Selector switch in position: Select an operation mode.

Low initial value. Initial value below 15 °C, i.e. no need for heating. Thermostat valve / valves in radiator system or room thermostat of floor-based heating system set for low temperature.

Set thermostat valve / valve or room thermostat to desired temperature.

Operation and status indicator illuminated, no heat or not enough heat.

Incorrectly set regulators. Check selections regarding heating graph, transition heating graph, maximum temperature and night-time temperature drop. Check selector setting.

Overheating (maximum safe tempe-rature) protection function has been triggered.

If overheating (maximum safe temperature) protection function has been triggered, check functioning of circulation pump and valves. Reset by pressing overheating (maximum safe temperature) protection button down after temperature has dropped below 80 °C.

Electric boiler fun-ctions normally, but not enough heat.

Counter-pressure in heating system has exceeded overflow valve’s ope-ning pressure.

Check heating system’s counter-pressure. Contact plumber.

Electric boiler’s group fuses blown.

Electric cartridge damaged. Check electric cartridge’s isolation. If electric cartridge has to be replaced, it is important to separate the loops in order to avoid sound of boiling alarm.

Water leaks out from air-bleeder.

Impurities in air-bleeder or broken air-bleeder.

Replace or clean air-bleeder.

Resistance values of boiler’s temperature sensor

NOTE! The sensor must not be connected to the circuit board while readings are taken.

Boiler/Outgoing water temperature sensor0 ºC R(Ω) 0 ºC R(Ω)0 32,7 k 50 3,6 k 5 25,4 k 55 3,0 k 10 19,9 k 60 2,5 k 15 15,7 k 65 2,1 k 20 12,5 k 70 1,8 k 25 10,0 k 75 1,5 k 30 8,1 k 80 1,3 k 35 6,5 k 85 1,1 k 40 5,3 k 90 915 45 4,4 k 95 787

Outside temperature sensor0 ºC R(Ω) 0 ºC R(Ω)-35 64,2 ±0 8,0 -30 47,0 5 6,8 -25 34,7 10 5,3 -20 25,9 15 4,2 -15 19,5 20 3,4 -10 14,8 25 2,7 -5 11,4 30 2,2

Assembly instructions | LK Electric Boiler 11-n

Page 15: Construction - lksystems.se · CURVE: KURVA 4 If the button is depressed for 2 sec, the pump switches to setup mode and the LEDs flash. In setup mode, any one of 10 curves can be

15 (15)

EN.33.C.94.1901

Energy declaration Condensing boiler NoLow-temperature boiler NoB1 boiler NoCogeneration space heater

No

Built-in tap water heating NoRated heat output Prated 11 kWUseful heat output P4 11,0 kWEnergy class DSeasonal average effi-ciency for space heating

Boiler ηs 37% Boiler with UTK 39%

Additional power consumption

In standby mode PSB 0,003 kW

Standby heat loss Pstby 0,022 kW

Outside temperature compensator

UTK E Class: II 2% contribution to Season medium efficiency

RecyclingAfter dismantling the boiler must be recycled. The insulation is removed and recycled as insu-lation. Boiler body and boiler casing recycled as scrap steel. Electrical and electronic components are sorted as electronic waste.

Assembly instructions | LK Electric Boiler 11-n

LK Systems AB, Box 66, 161 26 Bromma, Sweden | www.lksystems.se