connectivit y & it rodrigo franco connectivity & it latam leader

29
CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Upload: christian-bennett

Post on 28-Mar-2015

216 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

CONNECTIVITY

& ITRODRIGO FRANCO

Connectivity & IT LATAM Leader

Page 2: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader
Page 4: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader
Page 5: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

THE WAY MUST BE FINE BEFORESTARTING OUR ENGINES

Page 6: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

IT Hosptal Environment

• CORPORATE IT

SERVERS, CABLING INFRA

DATA CENTER

ENTERPRISE RESOURCE PLANNING

ERP

CUSTOMER RELATIONSHIP MANAGEMENT

CRM

Page 7: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

IT Hospital Environment

Challenge

• HOSPITAL IT

SERVERS AND CABLING

DATA CENTER

HOSPITAL INFORMATION SYSTEM

HIS

CLINICAL INFORMATION SYSTEMELECTRONIC MEDICAL RECORDS

CIS / EMR

RADIOLOGY INFORMATION SYSTEM

RIS

LABORATORY INFORMATION SYSTEM

LIS

Page 8: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

IT Hospital Environment• INFRASTRUCTURE

• DO YOU KNOW?

One OR/ICU room can reach more than 10Km (32,808’) of cables.

Page 9: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Estrutura de TI Hospitalar• INFRAESTRUTURA

• Cabo de Rede• Recomendações:• Cat 5e para UTI• Cat 6A Blindado para CC

Cables

• Rack utilizado para guardar equipamentos da redeRacks

• Utilizado para concentrar os cabos de rede.Patch Panel• Utilizado para unir a comunicação fisica e logica de uma rede • Recomendações:• CISCO Networks• Podem Ser Rodados em Layer 3

Switch• Equipamento utilizado para definir o trafego e as rotas de redes.• Recomendações:• CISCO NetworksRoteador

• Computadores super potentes para Instalação de Softwares em geral e armazenamento de dados• A GE fornece em conjunto com os softwares necessáriosServidores

Page 10: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Estrutura – Tecnologia Rede GE• INFRAESTRUCTURA – VLAN (RED ÚNICA)

+

Roteador

Switch

=Switch de Layer 3

VLAN1Monitores

VLAN2Hospital

LAN = Local Area NetworkVLAN = Virtual & Local Area NetworkWAN = Wide Area Network (Acesso a rede geograficamente ampla e externa)

ROUTING

Page 11: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Estrutura de TI Hospitalar

• INFRAESTRUCTURA

• Etapas:• Site Survey• Alcance del Proyecto• Implantación• Certificación

Page 12: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Connectivity

DCARMONITORS

CIC Pro

GEDRAGERMAQUETANESTESIA

GE / DRAGER

UNITY NETWORK

HIS/CISHOSPITAL

ACCESS RIS /HIS / CIS

CARESCAPE GATEWAY

MOBILE VIEWER

MARS

Page 13: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

WORKSTATION

RODRIGO FRANCO

Page 14: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Workstation

Connectivity Solution

• APPLICATIONWORKSTATION:

• RIS/Pacs• Intranet• HIS/CIS

CITRIX Server*Emulator Application ServerCompatibility XenApp 5.0

SERVERHIS/CIS

Citrix XenApp ?

is a thin client product that allows users to connect to their corporate applications. XenApp can host applications on central servers and allow users to interact with them remotely or stream and deliver them to user devices for local execution.

Page 15: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Workstation

Connectivity Solution

Page 16: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Carescape GatewayData back collection support (HL7 only)

Monitor offline scenario• Monitor online and sending data• Monitor is taken off the network

(possibly due to patient Transport) and the data feed stops

• Data capture continues in monitor

• Upon new network connection, up to eight (8) hours back collected data sent to EMR through CARESCAPE Gateway

ED

EMR offline scenario• EMR is offline for upgrade or

downtime• Gateway saves data in cache

and waits for EMR to return online

• When connection resumed, HL7 trended vital signs data resumes

• Gateway slowly feeds up to 12 hours of back collected data to EMR

ICU

CARESCAPE Gateway

EMR

Transport

Page 17: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Carescape Gateway

Vitals signs data sent withpatient demographic data

– CARESCAPE Gateway will transmit data based on assigned collection intervals

• Trended parameters• Intervals of 1-5, 10-, 15-, 30-, 45- and 60

minutes– Vitals on Demand

• Query is performed by assigned location• Current data is returned

– Data will be sent with• PID (PID.3)• Name (PID.5)• Unit/bed• Date of Birth (PID.8) S/5 Network only• Gender (PID.8) S/5 Network only

– Account number, name, date of birth, and gender can be attached to HL7 message based on a look-up in the ADT database

Example HL7 results message

Page 18: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Workstation

Connectivity Solution

Page 19: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

MOBILESOLUTIONS

RODRIGO FRANCO

Page 20: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Mobile Solutions

Mobile Care Solutions & Citrix

Client

Integrating patient monitoring and ITWEB VIEWER

PACS

CAMERAS

HIS

Page 21: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Centricity ACS Solutions

CENTRICITY ANESTHESIA

Page 22: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Centricity ACS Solutions

Page 23: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Centricity ACS Solutions

CENTRICITY CRITICAL CARE

Page 24: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

Centricity ACS Solutions

CENTRICITY CRITICAL CARE

Page 25: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

DCARCONNECTIVIT

YRODRIGO FRANCO

Page 26: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

DCAR – Report Central

MARS v8CENTRAL REPORTSCARDIOSOFT / MARS

HIS/EMR/PACSINTEGRATION

XML / PDF / DICOM 

REMOTE ACCESSVPN / Remote Desktop / Citrix

REMOTE CLINIC A REMOTE CLINIC B REMOTE CLINIC C

Internet Access

Web Upload

 

Stress / Mapa / Holter / ECG

Page 27: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

DCAR - CONNECTIVITYFILE SHARE

ExportECG

FolderECG

Tonoport

Stress

Cardiosoft

FolderDataBase

FolderPDF Results

PACSDICOM

CONNECTIVITYSERVICE

Page 28: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

DCAR - CONNECTIVITY

Clinical Convergence with MS• CIC – MARS Enterprise i• Full disclosure Holter• SCD Predictive algorithms

Web data transfer• Scanning centers• Enterprise networks• Remote sites

Clinical Research & Pharma• 12 Lead Recorder• 12SL Integration• Export in MUSE

New in MARS v8.0

MARS v8.0

REMOTE ACCESS

Page 29: CONNECTIVIT Y & IT RODRIGO FRANCO Connectivity & IT LATAM Leader

THANK YOUOBRIGADOGRACIAS

RODRIGO [email protected]