connection between generations - multi comfort · 2018. 8. 29. · superstructure of the 5 -th...

25
CONNECTION BETWEEN GENERATIONS MULTI-COMFORT HOUSE STUDENT CONTEST EDITION 2017 URBAN REGENERATION OF A COMMUNITY IN MADRID UKRAINE, KNUCA, ALINA HOLOVATIUK

Upload: others

Post on 08-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

CONNECTION BETWEEN GENERATIONS

MULTI-COMFORT HOUSE STUDENT CONTEST EDITION 2017

URBAN REGENERATION OF A COMMUNITY IN MADRIDUKRAINE, KNUCA, ALINA HOLOVATIUK

Page 2: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

RENOVATION – COMFORT – COMMUNICATION – AKTIVISATION – SUSTAINABILITY

CONCEPT

CONNECTIONBETWEENGENERATIONS

Page 3: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

CURRENT SITUATION

CONNECTIONBETWEENGENERATIONS

Page 4: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

COURTYARD - COMMUNITY ZONE

CONNECTIONBETWEENGENERATIONS

Page 5: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

SUPERSTRUCTURE OF THE 5-TH FLOOR WITH EXPLOITABLE ROOF - 840000 €

INSULATION OF BUILDINGS AND MOUNTING OF SUN SCHIELDS - 55800 €

CONNECTIONBETWEENGENERATIONS

EXTENTION OF ELEVATORS-98400 €

INCREASE THE WINDOW OPENINGS IN THE SOUTH FACADES FOR INSOLATION AND REPLACEMENT OF THE WINDOWS -102400 €

EXTENSION OF OPENGALLERIES (FOR FACADES FACING THE COURTYARD)-154800 €

ADAPTATION THE GROUNDFLOOR FOR PUBLICFUNCTIONS + LANDSCAPING OF THE COURTYARD- 216000 €

€SALE OF THE FIRST FLOORSFOR COMMERCIAL REAL ESTATE:360м² *2 *3000 € = 2160000 €

RENOVATION SHEME

CONSTRUCTION OF STYLOBATEFLOORING IN THE COURTYARD;REORGANIZATION OF WAREHOUSES -460000 €

TOTAL ACCORDING TO THE RENOVATION SHEME: 1927400 €

Page 6: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

ARC

HIT

ECTU

RAL

SO

LUTI

ON

Page 7: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

HOUSING

COURTYARD -COMMUNITY ZONE

CONNECTIONBETWEENGENERATIONS

PARK

CAFE - BAKERY

YOGA CLUB

LIBRARYCOMPUTER LITERACY CENTER FOR ELDERLY PEOPLE

HAIRDRESSING SALON

SOLAR COLLECTORSSOLAR PANELS

MINI-GARDEN

COOKERY

PATIO + MINI-GARDENS

SOLAR COLLECTORS 51m²

SOLAR PANELS 249 m²

ART WORKSHOPART STUDIO

SHOP

PHARMACY

STORAGE

FUNCTIONAL SHEME

Page 8: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

CONNECTIONBETWEENGENERATIONS

MASTER PLAN

Page 9: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

CONNECTIONBETWEENGENERATIONS

INCLINEDPLATFORM LIFT

Page 10: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

CONNECTIONBETWEENGENERATIONS

1st FLOOR PLAN

INCLINEDPLATFORM LIFT

Page 11: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

CONNECTIONBETWEENGENERATIONS

PATIO ON THE ROOF

Page 12: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

CONSTRUCTION AND TECHNIСAL SOLUTIONS

Page 13: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun
Page 14: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun
Page 15: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

DETAIL “F”

DETAIL “E”

Page 16: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

SOUND INSULATION OF THE CEILING SAINT-GOBAINECOPHON COMBISON DUO E, Rw40dB

TRIPPLE GLAZING SGG CLIMATOP ACOUSTIC, Rw40dB

ACOUSTIC INSULATION ISOVER AKUSTIC EP3, Lw 25dB

BEARING BRICK WALLS WITH INTERNAL PLASTER ON BOTH SIDES + ACOUSTIC INSULATION ISOVER 30мм, Rw 63dB, REI 120

1

234

ACOUSTIC INSULATION ISOVER SILLATHERMWVP 1-035 (160mm)+ BRICK WALL 290mm,Rw68dB

GREENERY,Rw10dB

PARTITION WALL S-1M-2GKL, ACOUSTIC INSULATION ISOVER GLASS WOOL, Rw56dBROOF STRUCTURE WITH ACOUSTIC INSULATION ISOVER METAC FLP 1-037 DURATEC (160mm), Rw 68dB, Lw 42dB

5

678

ACOUSTIC COMFORT - FIRE SAFETY

Page 17: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

LIGHT TRANSMITANCE 75%DAYLIGHT AUTONOMY >62%

EXTERNAL SUN SCREEN SHADING

FRESH AIR SUPPLY:

NIGHT VENTILATION -FULLY OPEN WIND +’(25%)’1hDAY VENTILATION -FULLY OPEN WIND +’(25%)’1h

RAINWATER STORAGE

1

23

5

THERMAL COMFORT – VISUAL COMFORT – WATER REUSE

4

PASSIVE WINTER HEATING

Page 18: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

SOLAR ENERGY - HEATING - COOLING - VENTILATION

CALCULATION OF THE AMOUNT OF ELECTRICITY FROM SOLAR PANELS:8 м² OF THE ROOF -1кWh ELECTROENERGY 240 м²(ROOF SQUARE FOR SOLAR PANELS)/8= =30кWhPAYBACK PERIOD(1kW= 0,23€): 1,56 YEAR

CALCULATION OF THE REQUIRED NUMBER OF SOLAR COLLECTORS:58 кWh / 4.57кWh / м²*day / 0,8(COP)= =16 м²- FLAT COLLECTORSPAYBACK PERIOD(350 € = 2 м²): 0,6 YEAR

CALCULATION OF REQUIRED PERFORMANCE OF RECUPERATOR:70 м² (APARTMENT AREA) * 2.5М = 150 м³AIREXCHANGE 60% PER HOUR – 90 м³/h 90 м³/h * 10(NUMBER OF APARTMENTSPER SECTION)=900 м³/hPAYBACK PERIOD: 4,9 YEAR

Page 19: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

A.PROJECT DATAOBJECT: HOUSINGCLIMATE ZONE: MADRIDCONSTRUCTION: RENOVATIONBUILDING TYPE: RESIDENTIALUSAGE: FOR LIVINGDESIGN TEMPERATURE: 20.00°C

B. AREA INPUTSUM OF LIVING AREA: 2604.95 m²SUM OF HEATING SPACE VOLUME: 6772.87 m²V/A RATIO: 0.38SUM OF THERMAL ENVELOPE: 3293.86 m²

C. ENVELOPE-OPAQUE ELEMENTS (AVERAGE U-VALUES)FLAT ROOF: 0.19WALL AGAINST AIR: 0.19 SLAB AGAINST UNHEATED CELLAR: 0.47

D.ENVELOPE-WINDOWS AND DOORS(AVERAGE U-VALUES)WINDOWS: 0.7DOORS: 0.7

E. QUALITYAIRTIGHTNESS RATE: 1THERMAL BRIDGE FREE: YES

MULTI-COMFORT DESIGNERF. MEAN SHADING FACTORSNORTH 0°: 0.17SOUTH 180°: 0.0WEST 270°: 0.7EAST 90°: 0.7

OVERHEATING PARAMETERSKIND OF CONSTRUCTION: MASSIVE MAX. ADMITTED INTERIORTEMPERATURE: 25

SUMMER VENTILATIONSTRATEGYSUMMER AIR EXCHANGE RATE: 0.33NIGHT VENTILATION: FULLY OPEN WIND +’(25%)’1hDAY VENTILATION: FULLY OPEN WIND +’(25%)’1h

G.HVACHEAT RECOVERY SYSTEM: 80.00 %SUBSOIL HEAT EXCHANGER: 25

H.CALCULATIONS

SPECIFIC ANNUAL HEAT DEMAND: 8.80 kWh/(m²a)SPECIFIC ANNUAL COOLING DEMAND: 13.47 kWh/(m²a)OVERHEATING FREQUENCY : 0.00%

OVERHEATING

Page 20: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

COST ACCORDING TO THE PROPOSED

RENOVATION SHEME - 1927400 €

SOLLAR COLLECTORS - 16800 €

SALE OF THE FIRST FLOORSFOR COMMERCIAL REAL ESTATE:

360м² *2 *3000 € = 2160000 €

CONTROL VENTILATION

SYSTEM - 90000 €

SOLLAR BATTERIES - 60000 €

HEAT PUMP - 60000 €

TOTAL : 2154200 € <

Page 21: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

PARK

CONNECTIONBETWEENGENERATIONS

Page 22: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

PARK PLAYGROUND

Page 23: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

INSTALLATION “WISH BOARD”

Page 24: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

PARK FOUNTAIN

Page 25: CONNECTION BETWEEN GENERATIONS - Multi Comfort · 2018. 8. 29. · superstructure of the 5 -th floor with exploitable roof - 840000 € insulation of buildings and mounting of sun

CONNECTIONBETWEENGENERATIONS

CONNECTIONBETWEENGENERATIONSTH

ANK

YOU

!