Page 1: Configuring Ethernet Over PDH

Configuring Ethernet over PDHMINI-LINK TN ETSI

OPERATING INSTRUCTIONS

30/1543-CSH 109 32/1-V1 Uen J

Page 2: Configuring Ethernet Over PDH

Copyright

© Ericsson AB 2009–2010. All rights reserved. No part of this document may bereproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due tocontinued progress in methodology, design and manufacturing. Ericsson shallhave no liability for any error or damage of any kind resulting from the useof this document.

30/1543-CSH 109 32/1-V1 Uen J | 2010-10-28

Page 3: Configuring Ethernet Over PDH

Contents

Contents

1 Introduction 1

2 Safety Information 1

3 Preparations 1

3.1 Additional Preparations 1

4 Configuring Ethernet over PDH 2

4.1 Configuring Ethernet over PDH using the Ethernet Switch 3

4.2 Configuring Ethernet over PDH using Layer 1 Connection 4

5 Configuring PDH-IME 4

Reference List 7

30/1543-CSH 109 32/1-V1 Uen J | 2010-10-28

Page 4: Configuring Ethernet Over PDH

Configuring Ethernet over PDH

30/1543-CSH 109 32/1-V1 Uen J | 2010-10-28

Page 5: Configuring Ethernet Over PDH

Preparations

1 Introduction

This instruction describes how to configure Ethernet traffic over PlesiochronousDigital Hierarchy (PDH) in MINI-LINK TN.

2 Safety InformationMake sure that the information in the following documents has been understoodby the persons performing the procedures:• Personal Health and Safety Information, Reference [7]• System Safety Information, Reference [9]• Supplementary Safety Information for MINI-LINK, Reference [8]

3 Preparations

This section presents the preparations needed for a successful completionof the procedures in this instruction.

3.1 Additional Preparations

Consider the following additional preparations:

• Read through all applicable sections and make sure referenced documentsare available.

• Access the NE using MINI-LINK Craft. For more information, see Accessinga Network Element, Reference [1].

130/1543-CSH 109 32/1-V1 Uen J | 2010-10-28

Page 6: Configuring Ethernet Over PDH

Configuring Ethernet over PDH

4 Configuring Ethernet over PDH

Figure 1 shows an overview of the Ethernet services for Ethernet over PDH.

Layer 2 Connection

Network Element

Layer 2 Connection

Network Element

Ethernet Switch Ethernet Switch

SwitchPort

SwitchPort

SwitchPort

WAN LAN

LAN

SwitchPort

WANLAN

LAN

Radio-link

11819

PDH-IMEPDH-IME

Layer 1Connection

Layer 1Connection

Figure 1 Ethernet Overview

1. A configuration of Ethernet is set up for Ethernet over PDH with PDHInverse Multiplexing for Ethernet (PDH-IME).

2. WAN and LAN is configured, and for the connection between them either ofthe following is used:

• Ethernet Switch (Layer 2 Connection)

• Layer 1 Connection

If an Ethernet Switch is used, LAG (optional) and VLAN are also configured.

The node must be equipped with the following hardware:

• NPU3 B or NPU1 C

2 30/1543-CSH 109 32/1-V1 Uen J | 2010-10-28

Page 7: Configuring Ethernet Over PDH

Configuring Ethernet over PDH

• ETU3 or ETU2 B

• MMU2 B/C/D/H

See also the following for overview information: Ethernet over PDHConfiguration Flowchart, Reference [4].

It is also possible to perform a basic configuration of Ethernet over PDH withthe help of MINI-LINK Craft wizards.

Figure 2 MINI-LINK Craft Wizards

See MINI-LINK Craft User Guide, Reference [5] and MINI-LINK Craft UserInterface Descriptions, Reference [6] for more information about the wizards.

4.1 Configuring Ethernet over PDH using the EthernetSwitch

The following are the main steps when configuring Ethernet over PDH using theEthernet switch:

1. Configure the radio links, see Configuration Management Operations,Reference [2].

2. Configure the PDH-IME capacity and connect it to Ethernet, see Section 5on page 4.

3. Activate the Ethernet switch, see Configuring Ethernet, Reference [3].

4. Connect the WAN and LAN interfaces to the switch ports, see ConfiguringEthernet, Reference [3].

5. Configure LAG at the Ethernet switch, see Configuring Ethernet, Reference[3].

6. Configure a VLAN and add the switch ports to the VLAN, see ConfiguringEthernet, Reference [3].

7. Configure the switch ports, see Configuring Ethernet, Reference [3].

330/1543-CSH 109 32/1-V1 Uen J | 2010-10-28

Page 8: Configuring Ethernet Over PDH

Configuring Ethernet over PDH

After these steps, it is possible to continue with the following configurations (seeConfiguring Ethernet, Reference [3]):• Spanning Tree• Quality of Service• Static Unicast Filtering• Static Multicast Filtering• MAC Address White Lists• LAN-DCN Interfaces

4.2 Configuring Ethernet over PDH using Layer 1Connection

The following are the main steps when configuring Ethernet over PDH usingLayer 1 Connection:

1. Configure the radio link, see Configuration Management Operations,Reference [2].

2. Configure the PDH-IME capacity and connect it to Ethernet, see Section 5on page 4.

3. Connect the WAN and LAN interfaces to Layer 1 and create a Layer 1Connection, see Configuring Ethernet, Reference [3].

5 Configuring PDH-IME

This section describes how to configure Ethernet over PDH functionality usingPDH-IME.

PDH-IMEs are inverse multiplexers located on ETU3/ETU2 B. Inversemultiplexing speeds up data transmission by dividing a data stream into multipleconcurrent streams that are transmitted at the same time across separate E1channels and are then reconstructed at the other end back into the originaldata stream.

An ETU3/ETU2 B has six PDH-IMEs divided into two groups:• PDH-IME 1, 2, and 6• PDH-IME 3, 4, and 5

A maximum of 48 E1s can be assigned to each of these PDH-IME groups fora total capacity of maximum 96 E1s.

4 30/1543-CSH 109 32/1-V1 Uen J | 2010-10-28

Page 9: Configuring Ethernet Over PDH

Configuring PDH-IME

For example, if PDH-IME 1 is assigned 48 E1s, then PDH-IME 2 and PDH-IME6 cannot be assigned any. Another 48 E1s can still be assigned to PDH-IME3, 4, and 5.

To configure Ethernet over PDH functionality using PDH-IME:

1. In the Management Tree, expand an ETU3 or ETU2 B.

2. Right-click a PDH-IME.

3. Click Configure and then click General.

4. In the Connect to list, select Ethernet.

5. Set the other parameters. For more information about the parameters, seeMINI-LINK Craft User Interface Descriptions, Reference [6].

6. On the File menu, click Save to apply changes.

7. Right-click the configured PDH-IME and click Configure and then clickCapacity.

8. Do the following to assign E1s to the PDH-IME:

• Under Modules, select the plug-in that contains the E1s to be assignedto the PDH-IME.

• Under Available E1, select the E1s to be assigned to the PDH-IME.

• Click to move the selected E1s to the Assigned E1 list. UseCTRL or SHIFT to select multiple items.

Repeat these steps for each plug-in unit containing E1s to be assignedto the PDH-IME.

Note: Up to 48 E1s can be assigned to a PDH-IME. However, to assignmore than 16 E1s to a PDH-IME, you must do the following:

• Assign the first 16 E1s and then click Save on the File menu.

• Make sure the radio link is up and that at least one E1 isassigned to the PDH-IME in the far-end NE.

• Assign the remaining (up to 32) E1s and then click Save onthe File menu.

• Make sure that the same number of E1s are assigned to thePDH-IMEs on both sides of the radio link.

9. On the File menu, click Save to apply changes.

When the PDH-IME is connected to Ethernet, a new WAN interface is added inthe Management Tree. To locate the new WAN interface, expand Ethernet

530/1543-CSH 109 32/1-V1 Uen J | 2010-10-28

Page 10: Configuring Ethernet Over PDH

Configuring Ethernet over PDH

and WAN Interfaces The new WAN interface has the same physical name(Subrack/Position/Port) as the PDH-IME.

Note: There are a maximum of seven WAN interfaces available for NPU3 Band 20 WAN interfaces available for NPU1 C. For example, for anNPU3 B, if six WAN interfaces are used by the PDH-IMEs in oneETU3/ETU2 B, only one WAN interface is available for a secondETU3/ETU2 B.

The WAN interface can be connected to a port on the Ethernet switch or be usedin a Layer 1 Connection configuration, see Configuring Ethernet, Reference [3].

6 30/1543-CSH 109 32/1-V1 Uen J | 2010-10-28

Page 11: Configuring Ethernet Over PDH

Reference List

Reference List

[1] Accessing a Network Element, 3/1543-CSH 109 32/1-V1

[2] Configuration Management Operations, 6/1543-CSH 109 32/1-V1

[3] Configuring Ethernet, 18/1543-CSH 109 32/1-V1

[4] Ethernet over PDH Configuration Flowchart, 4/1553-CSH 109 32/1-V1

[5] MINI-LINK Craft User Guide, 1/1553-CSH 109 32/1-V1

[6] MINI-LINK Craft User Interface Descriptions, 7/1551-CSH 109 32/1-V1

[7] Personal Health and Safety Information, 124 46-2885

[8] Supplementary Safety Information for MINI-LINK, 124 46-HSD 101 16/1

[9] System Safety Information, 124 46-2886

730/1543-CSH 109 32/1-V1 Uen J | 2010-10-28