Confidential Inspection Report Prepared For: Greg Smith Property Address: 1930-32 Anderson Lodi, CA 95242 Agent: Nick Kerns Report #: 1930A Date: 5/1/2017 MHI Home Inspection fee 350.00 $ Pentecost Pest Inspection fee 125.00 $ Roof Doctors inspection fee Free Total Fees: 475.00 $ Paid in full M H I 1930-32 Anderson Lod 5/1/2017 Pictures and report is the exclusive property of the inspection company and the client whose name appears herewith for the purpose of obtaining financing and its use by any unauthorized persons is prohibited. By acceptance of this inspection report client agrees (signed or unsigned by client) to the terms of the 3 page inspection agreement attached. 1

Upload: others

Post on 04-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

Confidential Inspection Report

Prepared For:

Greg Smith

Property Address:1930-32 Anderson Lodi, CA 95242

Agent: Nick Kerns

Report #: 1930A

Date: 5/1/2017

MHI Home Inspection fee 350.00$

Pentecost Pest Inspection fee 125.00$

Roof Doctors inspection fee Free

Total Fees: 475.00$ Paid in full

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

Pictures and report is the exclusive property of the inspection company and the client whose name appears herewith for the purpose of obtaining financing and its use by any unauthorized persons is prohibited. By acceptance of this inspection report client agrees (signed or unsigned by client) to the terms of the 3 page inspection agreement attached.

Pictures and report is the exclusive property of the inspection company and the client whose name appears herewith for the purpose of obtaining financing and its use by any unauthorized persons is prohibited. By acceptance of this inspection report client agrees (signed or unsigned by client) to the terms of the 3 page inspection agreement attached.

1

Page 2: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

Report Table of Contents

COVER PAGE

INTRODUCTION

LOTS AND GROUNDS

EXTERIOR SURFACE & COMPONENTS

ROOF COVERING

POOL/SPA EQUIPMENT

GARAGE/PARKING

MAIN ELECTRICAL

HEAT AND AIR CONDITIONG

WATER HEATER Per Unit

PLUMBING SUPPLY AND DRAINS Per Unit

FIREPLACE Per Unit

INTERIOR ROOMS Per Unit

KITCHEN Per Unit

LAUNDRY Per Unit

BATHROOMS Per Unit

BEDROOMS Per Unit

ATTIC AREA AND SUB FLOOR

BEYOND THE SCOPE

3 PAGE INSPECTION AGREEMENT ATTACHED

INTRODUCTION

REPORT #: 1930A

INSPECTION DATE: 5/1/2017

Property address: 1930-32 Anderson Lodi, CA 95242

Building Type: Multi Family Complex, wood frame

Age: 1973

Address Facing/Stories/Size: W / one / 1944 sf TOTAL

19 30 A size/bed/ba 972 sf / 2 bd / 1.5 ba

19 32 B size/bed/ba 972 sf / 2 bd / 1.5 ba

Water/Sewage: public

Building occupied: yes

People present: tenants

M H I 1930-32 Anderson Lodi, CA 952425/1/20172

Page 3: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients' request. Enclosed is our written report based on that inspection. This report will give you information about the overall condition of this property.

We will examine the readily accessible areas and systems of the home.

Cosmetic considerations are not within the scope of this report, since all properties have some degree of wear. There may be many items that even the most thorough inspection cannot reveal, which you may consider significant to ownership. Furthermore, owning any building involves some risk and while we can give an excellent overview of the property, we cannot inspect what we cannot see.

We do not move furniture, stored personal effects or dismantle any part of the home in the course of our inspection. We do not do an exhaustive technical evaluation of the property; such an inspection is available for an additional fee. Your attention is directed to the INSPECTION AGREEMENT, a copy of which was provided; this letter makes it a part of the inspection report. It more specifically delineates the scope of the inspection and the limit of liability of the inspector and inspection company in performing this inspection. Please be sure to read and understand the scope of our inspection.We cannot make repairs nor refer contractors for repairs or maintenance on items which our report mentions, since we abide by the California Business & Professions Code.

NOTE: The client is strongly advised to further investigate or contract with appropriate persons to further investigate any and/all conditions/items in the inspection report not listed as (S) Serviceable, or are Inaccessible, Beyond the scope or which may have been disclosed by others or which you may be concerned about before the close of escrow or sooner if your residential purchase agreement has a contingency time limit.

Any statements made in the body of the inspection report pertaining to right, left, front or rear are referenced to viewing from the street and facing the dwelling.We advise clients to obtain owner’s manuals and warranties for all equipment/appliances installed in the dwelling. We advise clients to ask for any/all permits and inspection records with final signatures for any modifications or additions that may have been made to the dwelling, and/or any known conditions that may have been inadvertently left out of disclosure statements.

We advise having all exterior door locks rekeyed and the garage opener if present re programmed after taking possession of the home for security reasons.

3

Page 4: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

Photographs, when used, are simply a tool to convey our findings, they are not intended to enhance those findings or diminish any findings not photographed. Client is advised to thoroughly read the complete report as not all conditions reported will be represented by photographs.

NOTE: This report contains technical information that may not be readily understandable to the lay person. Therefore, a verbal consultation with the inspector is a mandatory part of this inspection report. If you choose not to consult with the inspector, this inspection company cannot be held liable for your understanding or misunderstanding of this report's contents. If you were not present during this inspection, please call the office to arrange for your verbal consultation.

Important notice to third parties or other purchasers: Receipt of this report by any purchasers of this property other than the above listed party(s) is not authorized by the inspector. This report prepared for the sole and exclusive use for the client listed above in accordance with our written agreement and is subject to the terms and conditions agreed upon, this report is a work product and is copyrighted by the company shown above as of the date of this report. Duplication by any means whatsoever is prohibited without prior written permission and authorization from the company shown above. Unauthorized duplication of, use of or reliance on this report has the effect of all parties agreeing to hold harmless, individually, jointly, and/or otherwise, the inspector, the Company, their successors and assigns. The inspector strongly advises against any reliance on this report by third parties. This document is not to be used for the purpose of substitute disclosure. We recommend that you retain a qualified professional inspector to provide you with your own inspection report on this property.

KEY TO THE INSPECTION REPORT

In using your report, the following definitions may be helpful.

S/Serviceable= Items noted at time of inspection were accessible and found to be in working order/serviceable condition (excluding cosmetic consideration and normal wear.)

N/A or None = The item does not apply to this property or none present.

IN inaccessible = Unable to access or unable to view..

RR = Recommended Repair .= Contact a qualified Contractor licensed for each particular Recommended Repair to evaluate and make repairs.

= Recommended Repair = CALL TO ACTION HEALTH & SAFETY REPAIRS

Items not permanently affixed and/or hard wired to home, such as track lighting attached to ceiling using receptacle plug for power source, is considered personal or portable property, and are not included in this report.

We realize that you had a number of companies to choose from to perform this service, and you chose us! The inspector and staff thank you for selecting our company for your home inspection needs. If you have any questions, please call us.

This report is the exclusive property of the inspection company and the client whose name appears herewith and its use by any unauthorized persons is prohibited.

RR

4

Page 5: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

EXTERIOR-STRUCTURE

LOTS AND GROUNDS

1 S WALKS: concrete

2 na EXTERIOR STAIRS:

3 na RAILINGS:

4 S PARKING:

5 S DRIVEWAY: concrete

6 S FENCES: wood and cement block

7 IN LAWN SPRINKLERS:

8 RR Exterior Fire extinguishers: none

9 S PORCHES: concrete, cracks noted

10 S DRAINAGE: No standing water noted. No drainage system noted.

Comments: Shed noted in rear yard of unit A and chicken coup in rear yard of unit B

PLUMBING SUPPLY AND DRAIN1 S SERVICE LINE: Underground, concealed and or buried piping is not inspected or tested.

2 S MAIN SHUT OFF: front

3 S WATER LINES: galvanized and copper

4 S DRAIN PIPES: ABS & Cast iron.

5 RR HOSE BIBS: No anti siphon devices installed

Hose bib missing at entry unit B.

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

Inspection of the exterior and immediate surrounding areas is limited to visible and readily accessible areas, areas hidden from view by vegetation, at or below grade level and/or behind walls or stored items cannot be judged and are not part of this inspection, taking into account typical wear for properties of this age and type (excluding cosmetic considerations). Moisture intrusion through cracks or openings in the exterior siding, trim, windows and doors is a source of moisture damage and deterioration. We recommend sealing all cracks and openings in and between the exterior siding and trim materials, especially around doors and windows. Routine maintenance and painting may extend the service life and minimize deterioration of the exterior surfaces

The visible areas only of the main water line, shutoff valve, water supply and drain lines, gas meter and piping are examined todetermine their current condition. Areas concealed from view by any means are excluded from this report/inspection. Leakage, blockage or corrosion in underground or concealed piping cannot be detected by a visual examination. A video inspection of drain/waste lines by an appropriate specialist is recommended if client is concerned by this possibility. Older fixtures or components should be budgeted for replacement. Shutoff valves are not operated by the inspector as they may be prone to leakage if they have not been frequently operated. Private waste disposal system's are not inspected, beyond the scope of this inspection.

5

Page 6: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

EXTERIOR SURFACE & COMPONENTS

1 RR SIDING: material Seal all holes to keep a water tight seal.

Stress cracks and paint peeling noted on rear of building.

2 RR TRIM: wood Paint all raw wood showing on garage door jambs.

3 RR FASCIA: Wood decay noted at entry.

Barge rafters are ready for re painting raw wood showing.

4 RR SOFFITS: wood Paint all raw wood left from past soffit repairs around the home.

M H I 1930-32 Anderson Lodi, CA 952425/1/2017 6

Page 7: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

5 RR ELECTRICAL: ext. Exterior plug missing water proof cap. Unable to access to check for

GFCI operation.

6 S GAS METER:

7 S MAIN GAS SHUTOFF: Located at gas meter

8 NA CHIMINEY:

9 RR WINDOWS: Vinyl frame double pane

We cannot assure the seal on each and every window, but we will note

in the report the presence of visible condensation at the time of inspection.

10 RR GUTTERS: End caps leaking above both garage side doors causing wood decay to

rafter tails and water to enter behind stucco.

11 RR DOWNSPOUTS: Kickers noted missing.

12 S FOUNDATION: slab

13 na CRAWL SPACE:

14 S WEEP SCREED:

M H I 1930-32 Anderson Lodi, CA 952425/1/2017 7

Page 8: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

ROOF COVERING (See roof inspection report provided by The Roof Doctors)

1 IN MATERIAL: Composition Asphalt Shingle

The roof doctors will walk the roof and their report will detail their findings

and cost of repairs if any exist.

2 S VALLEYS:

3 S FLASHINGS:

4 S PLUMBING VENTS:

Comments:

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

Our roof inspection is to report on the type and condition of roofing materials, missing and/or damaged material, and attachments (excluding antennas, solar systems, etc.) where visible. This does not constitute a warranty, guarantee, roof certification or life expectancy evaluation of any kind. Roofs are not water tested for leaks. Condition of the roofing underlayment material is not verified/inspected. For further evaluation and a roofing certification we recommend you consult a qualified licensed roofing contractor, a number of lenders may require a roofing certification. Building's that have tile or wood shingle/shake materials and are going to be tested for termites should be re inspected for possible damage caused by the extermination process before the close of escrow.

8

Page 9: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

GARAGE/PARKING STRUCTUREUNIT A

1 RR GARAGE DOORS: Aluminum roll up. 2 car garage.

Bottom two panels are damaged unable to open door.

2 IN DOOR OPENER: Unable to test

3 S CEILING: open rafter

Items noted stored in rafters

4 S WALLS: Drywall

5 S SIDE DOOR: Wood

6 na HOUSE DOOR:

7 S FLOOR: Concrete

8 S WINDOWS:

9 IN ELECTRICAL: Stored items along walls prevent complete inspection of garage

GARAGE/PARKING STRUCTUREUNIT B

1 S GARAGE DOORS: Aluminum roll up. 2 car garage.

2 S DOOR OPENER: Unable to test

3 S CEILING: open rafter

Items noted stored in rafters

4 S WALLS: Drywall

5 S SIDE DOOR: Wood

6 na HOUSE DOOR:

7 S FLOOR: Concrete

8 S WINDOWS:

9 IN ELECTRICAL: Stored items along walls prevent complete inspection of garage

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

When a door opener's safety reverse function fails to operate, the problem may be improper adjustment, or it may be something more serious and costly. With some openers, auto-reverse mechanisms may need replacement, not merely readjustment. With older door openers, many were never designed with automatic safety reverse. Upgrading these units is recommended for safety. Your garage door should also be balanced so that it will stay in place when the emergency release is unexpectedly crash to the floor causing injury. The inspector did not test this function. The U.S. Product Safety

9

Page 10: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

MAJOR SYSTEMS

MAIN ELECTRICAL

1 S METER SERVICE:

2 S OVERLOAD PROTECTION: Overload protection is provided by breakers. The

accuracy of labels when present are not verified.

3 S MAIN DISCONNECT: Unit A-B 100 amp breakers

4 na FUTURES:

5 IN CONDUCTORS: Unable to view inside panel appliances running in the home.

6 IN GROUND METHOD: Unable to view in wall.

Comments:

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

In older homes open grounds are quite commonly found, this is due to the original wiring systems not being upgraded to a three wire system or only selective areas being upgraded. The methods of grounding these receptacles vary greatly dependent on the period when they were installed or upgraded. When three prong receptacles with open grounds are identified and a two-wire system is present,(If this situation occurs a licensed electrical contractor needs to evaluate the whole house.)Ground fault circuit interrupter devices (GFCI) afford additional protection against electrical shock. GFCI protection is typically

found in newer homes in areas where electrical receptacles are located near sources of water. For your information, we have indicated in the report those areas which may be appropriate for GFCI installation and whether or not a device is in place. Upgrading unprotected plug outlets noted in the report is recommended for additional safety.

Our visual inspection of major systems is limited to the normal operating functions of items listed. Independent evaluations including the adequacy/inadequacy of water flow (such as gallons per minute), buried/concealed piping or water quality, electrical amperage/voltage adequacy and the testing of photoelectric cell operated fixtures are not within the scope of this report. If such detailed information is required, we suggest contacting appropriate specialists. Areas concealed from view by any means are excluded from this report/inspection. Any electrical repairs, modifications, corrections, installations or periodic inspection and maintenance of systems or aluminum wiring should be provided by a licensed and qualified electrician per California law.

10

Page 11: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

HEATING & AIR CONDITIONING SYSTEMUNIT A

Manufacturer: Bryant

Type: forced air dual pac

Approx. age unknown

Fuel type: natural gas

BTU's: unknown

Location: living room closet

1 S HEAT OPERATION: Functional at time of inspection.

2 S GAS LINE: noted with shut of valve and drip leg.

3 S VENT PIPE: Galvanized,

4 S COMBUSTION AIR:

5 RR FILTER: Replace dirty filter in return air register.

6 S THERMOSTAT: Worked at time of inspection.

7 S AC OPERATION: operational

8 S DISCONNECT: on stucco

RR Comments: Duct noted loose on plenum box.

UNIT B

Manufacturer: Bryant

Type: forced air dual pac

Approx. age unknown

Fuel type: natural gas

BTU's: unknown

Location: living room closet

1 S HEAT OPERATION:

2 S GAS LINE: noted with shut of valve and drip leg.

3 S VENT PIPE: Galvanized,

4 S COMBUSTION AIR:

5 RR FILTER: Replace dirty filter in return air register.

6 IN THERMOSTAT: Worked at time of inspection.

7 S AC OPERATION: operational

8 S DISCONNECT: on stucco

RR Comments: Ducts noted smashed restricting air flow.

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

Our inspection of major HVAC systems is limited to the normal operating functions of the items listed. Independent evaluations including the adequacy/inadequacy of heating and cooling systems (such as cracked heat exchangers, air conditioning pressure tests, coolant charge, line integrity, air balance, evaporator cooling coils.etc.) are not within the scope of this report. Thermostats are not checked for calibration or timed functions. If such detailed information is required, we suggest contacting appropriate HVAC specialists. Normal service and maintenance by a licensed HVAC specialist is recommended by the HVAC equipment manufacturer on an annual basis.DISMANTLING AND/OR EXTENSIVE INSPECTION OF INTERNAL COMPONENTS OF ANY APPLIANCE, INCLUDING

HEATERS AND HEAT EXCHANGERS, IS BEYOND THE SCOPE OF THIS REPORT. IN A NUMBER OF AREAS THE LOCAL UTILITY COMPANY MAY CONDUCT SUCH AN INSPECTION UPON REQUEST. MOST MANUFACTURES ADVISE ANNUAL

11

Page 12: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

WATER HEATER UNIT A

Brand: AO Smith

Size: 50

Approx. age: unknown

Location: garage

Fuel Type: natural gas

1 S OPERATION: Functional at time of inspection.

2 S GAS LINE: noted with shut of valve and drip leg.

3 RR VENT PIPE: Galvanized Minimum 6" clearance from combustibles required for single wall pipe.

4 S TRP VALVE/LINE:

5 S EARTHQUAKE STRAP:

6 S COMBUSTION AIR:

7 S WATER SHUT OFF: Cold water shutoff valve noted not operated.

Comment:

LIVING SPACEHALLWAYS

1 S Closets:

2 S Ceiling:

3 S Walls:

4 S Floor: carpet

5 na Doors:

6 S Electrical:

7 S Carbon Monoxide:

8 RR Smoke Alarm: non operational check batteries.

9 RR Staircase: Handrail does not extend to top step.

LIVING ROOM/DINING

9 S Ceiling:

10 S Walls:

11 RR Floor: Carpet noted loose.

12 S Front Door:

13 S Electrical:

14 S Windows:

MAIN ELECTRICAL PER UNIT

1 S SUB PANEL:

2 RR OVERLOAD PROTECTION: Breakers not labeled.

3 S DISCONNECT: at main panel

4 na FUTURES:

5 IN CONDUCTORS: Unable to view appliances running.

6 IN GROUND METHOD: Unable to view

M H I 1930-32 Anderson Lodi, CA 952425/1/201712

Page 13: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

KITCHEN UNIT A1 S Ceiling:

2 S Walls:

3 S Floor: Tile

4 na Doors:

5 S Windows:

6 RR Electrical: GFI plugs at kitchen sink area work.

Cut silver duct tape away from plug prongs.

7 IN Range: Gas range owned by tenant. Original electric range is in back shed.

8 na Microwave:

9 RR Hood vent: Clean or replace grease filter.

Exhaust pipe not properly hooked up, air is coming out to of microwave

10 RR Dishwasher: Drain line is not hooked up to an air gap.

11 S Sink:

12 S Faucet:

13 na Disposal:

14 RR Cabinets: Bottom of sink cabinet is water damaged.

15 S Countertop: slab

16 na Refrigerator: owned by tenant

17 S Fire Extinguisher:

LAUNDRY ROOM Unit ALocation: garage

1 S Washer hose bibs:

2 S Washer electrical:

3 S Dryer electrical:

4 na Dryer gas hookup:

5 S Dryer vent:

6 S Washer drain:

7 S Ceiling:

8 S Walls:

9 S Floor:

10 na Doors:

11 na Windows:

12 na Electrical:

13 na Laundry sink:

14 S Ventilation:

M H I 1930-32 Anderson Lodi, CA 952425/1/2017 13

Page 14: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

Bathroom UNIT A1/2 bath

1 S Ceiling:

2 S Walls:

3 S Floor: tile

4 S Doors:

5 na Windows:

6 S Electrical: GFCI works

7 na Shower/Surround:

8 na Tub:

9 RR Toilet: Loose. Tighten bolts and caulk base to floor. Replace wax ring if needed.

10 S Ventilation: fan

11 S Sink:

12 S Faucet/Trap:

13 na Shower Enclosure:

Bathroom Upstairs hall bath

1 S Ceiling:

2 S Walls:

3 S Floor: Linoleum

4 S Doors:

5 S Windows:

6 S Electrical:

7 RR Shower/Surround: plastic Re caulk wall to top of shower.

Remove caulk with mildew and re caulk with mildew resistant caulking.

8 S Tub: Caulk wall to tub to maintain water tight seal.

9 S Toilet:

10 S Ventilation: window

11 S Sink:

12 S Faucet/Trap:

13 RR Shower Enclosure: Glide at bottom does not hold door in place.

Comments:

M H I 1930-32 Anderson Lodi, CA 952425/1/2017 14

Page 15: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

BEDROOMS UNIT A

location Rear

1 IN Ceiling: Acoustical texture noted on ceilings in both units. During the time the home

was built asbestos was used for this type of texture & banned in 1978.

If concerned you can have the texture tested with a testing facility.

2 S Walls:

3 RR Floor: Carpet noted loose

4 S Doors:

5 S Windows:

6 S Electrical:

7 S Closet:

8 S Smoke detector:

9 S Heating:

location Front

1 S Ceiling:

2 S Walls:

3 S Floor: carpet

4 S Doors: Knob does not latch

5 S Windows:

6 RR Electrical: Loose conduit with romex wire noted on wall. Unknown use.

7 S Closet:

8 S Smoke detector:

9 S Heating:

M H I 1930-32 Anderson Lodi, CA 952425/1/2017 15

Page 16: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

WATER HEATER UNIT B

Brand: Blanket cover name

Size: 50

Approx. age: unknown

Location: garage

Fuel Type: natural gas

1 S OPERATION: Functional at time of inspection.

2 S GAS LINE: noted with shut of valve and drip leg.

3 RR VENT PIPE: Galvanized Strap pipe to rafters to keep it from coming loose from heater.

4 S TRP VALVE/LINE:

5 S EARTHQUAKE STRAP:

6 S COMBUSTION AIR:

7 S WATER SHUT OFF: Cold water shutoff valve noted not operated.

Comment:

LIVING SPACEHALLWAYS

1 S Closets:

2 S Ceiling:

3 S Walls:

4 RR Floor: carpet Carpet noted frayed at entry tile

5 S Doors:

6 S Electrical:

7 S Carbon Monoxide:

8 RR Smoke Alarm: None at top of stairs.

9 RR Staircase: Handrail does not extend to the top step.

LIVING ROOM/DINING

8 S Ceiling:

9 S Walls:

10 S Floor: carpet

11 S Front Door:

12 S Electrical:

13 S Windows:

MAIN ELECTRICAL PER UNIT

1 S SUB PANEL:

2 S OVERLOAD PROTECTION:

3 S DISCONNECT: at main panel

4 na FUTURES:

5 IN CONDUCTORS: unable to view appliances running

6 IN GROUND METHOD: unable to view

M H I 1930-32 Anderson Lodi, CA 952425/1/201716

Page 17: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

KITCHEN1 S Ceiling:

2 S Walls:

3 S Floor: Tile

4 na Doors:

5 S Windows:

6 RR Electrical: GFCI works

Plug above microwave missing cover plate.

7 S Range: gas

8 na Microwave:

9 RR Hood vent: Exhaust vent pipe was not properly hooked up air is coming out top

of microwave.

10 RR Dishwasher: Drain line is not hooked up to an air gap.

Unable to test dishwasher is being used for storage.

11 S Sink:

12 RR Faucet: Faucet is loose allowing water to drain into cabinet.

13 na Disposal:

14 RR Cabinets: Bottom of sink cabinet is water damaged.

15 S Countertop: slab

16 na Refrigerator: tenant owns

17 S Fire Extinguisher:

LAUNDRY ROOM/AREA UNIT BLocation: Garage

1 S Washer hose bibs:

2 S Washer electrical:

3 S Dryer electrical:

4 na Dryer gas hookup:

5 S Dryer vent:

6 S Washer drain:

7 S Ceiling:

8 S Walls:

9 S Floor:

10 na Doors:

11 na Windows:

12 na Electrical:

13 na Laundry sink:

14 S Ventilation:

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

17

Page 18: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

Bathroom UNIT B1/2 Bath

1 S Ceiling:

2 S Walls:

3 S Floor: tile

4 S Doors:

5 na Windows:

6 S Electrical: GFCI works

7 na Shower/Surround:

8 na Tub:

9 RR Toilet: Loose. Tighten bolts and caulk base to floor. Replace wax ring if needed.

10 S Ventilation:

11 S Sink:

12 S Faucet/Trap:

13 na Shower Enclosure:

Bathroom Upstairs Hall bath

1 S Ceiling:

2 RR Walls: Water damage noted left of tub.

Clean mildew growth around window jamb.

3 RR Floor: Cracked tiles noted.

4 S Doors:

5 S Windows:

6 S Electrical:

7 RR Shower/Surround: plastic Recaulk top of shower stall to maintain water tight seal.

Water valve leaks

8 RR Tub: Drain is clogged. Drains slowly.

9 RR Toilet: Loose. Tighten bolts and caulk base to floor. Replace wax ring if needed.

10 S Ventilation: window

11 S Sink:

12 S Faucet/Trap:

13 na Shower Enclosure:

Comments:

M H I 1930-32 Anderson Lodi, CA 952425/1/2017 18

Page 19: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

BEDROOMS UNIT B

location Rear

1 IN Ceiling: Texture noted cracked, unknown if from old roof leak.

2 S Walls:

3 S Floor: carpet

4 RR Doors: strike plate is missing

5 S Windows:

6 S Electrical:

7 S Closet:

8 S Smoke detector:

9 S Heating:

location Front

1 S Ceiling:

2 S Walls:

3 S Floor: carpet

4 S Doors:

5 S Windows:

6 S Electrical:

7 S Closet:

8 S Smoke detector:

9 S Heating:

M H I 1930-32 Anderson Lodi, CA 952425/1/2017 19

Page 20: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

ATTIC AREA & ROOF FRAMING

Viewed from: head shoulders view through attic access only.

1 S Hatch location: Bedroom closet.

2 S Roof Framing: Rafters

3 S Roof sheathing: Plywood over skip

4 S Ventilation: Attic vents

5 S Insulation: R11

6 IN Vapor Barrier: Unable to view paper/felt hidden from visual view.

7 S Evidence of leaking: I did not observe any indications of leakage during my inspection.

8 IN Electrical: Unable to view covered with insulation. Viewable electrical satisfactory.

9 RR Ducting: Loose vent pipe noted venting into attic space. Code requires exhaust

vent pipes to vent to the exterior.

IN Comments: The Home inspection report does not cover wood destroying organisms, dry rot,

fungus, mold or insects this is provided by a pest control inspection company.

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

The visible areas from a head and shoulders view from crawl hole of the sub floor, attic and roof framing were examined to determine their current condition and visible water stains. Areas concealed from view by any means are excluded from this report. Insulation is not moved during the inspection Sub floor & Attic framing members/components and other multiple items are tested by examining a representative sampling as opposed to specific functionality of every single item. The accessible permanently installed equipment or components are checked for basic operation. Thermostatically operated attic vent fans are excluded from the inspection.

20

Page 21: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

WHEN IT'S BEYOND THE SCOPE CONCEALED AREAS: If areas of the home are inaccessible or concealed from the inspectors view, then

an inspection of that area did not take place. 1) Request that any information about any hidden problems be revealed to you about these inaccessible or hidden areas from the seller prior to the close of escrow 2)Return to the property prior to the close of escrow and perform a walk-through inspection of your own after the owner's belongings have been removed 3) If your inspection or information reveals hidden damage or concerns contact a qualified specialist or your inspector for a return visit.

PERMITS/BUILDING CODE If you are concerned about code violations or building permit information

VIOLATIONS: you should: 1) Contract with a company to research permit information available at the

appropriate building and safety office. ) If you have additional concerns with regard to code violations you may contract for a code compliance survey of the

property. A typical home inspection is not such a service.

GEOLOGICAL Soil condition or stability is not determined during this home inspection.

STABILITY: Should you decide to obtain a geological report of the site conditions you might

contact a geological inspection firm through your real estate agent or a nonprofit

association of geotechnical engineers for referral.

STRUCTURAL STABILITY OR Engineering analysis of a building's structure is performed only by a

ENGINEERING ANALYSIS: licensed structural engineer with the use of measurements, calculations,

or other scientific evaluation. Engineering is beyond the scope of a typical home

inspection. To receive an inspection and report on the structure by an engineer,

ask your real estate agent or a non-profit association of structural engineers for

referral.

SEWER BLOCKAGE: Check with the seller for information about the history of the sewer or private waste disposal system. Having a drain service company video review and service the main drain line to be sure it is open and flowing before the close of escrow is recommended on all homes.

RADIO CONTROLLED Numerous devices in homes that are operated with remote controls are not within

DEVICES: the scope of this inspection. For information about these devices we first suggest

that you obtain a list of all the remote controls from the seller. (The operation of

the overhead garage door automatic opener will be tested using the permanent

control button provided in the house or garage.) Many radio controlled devices

have changeable codes which you may want to consider altering for your use or

safety. You may wish to contact the installer or manufacturer for additional

information and evaluation.

REINSPECTION AND Re-inspection's are only performed on items not accessible at the time of original

REPAIRS: inspection or that were unable to be inspected due to utilities not turned on.

Should repairs be necessary we suggest they be performed by appropriate

persons and that work complies with applicable Law, including governmental

permit, inspection, and approval requirements. Buyer should obtain from seller

receipts for Repairs performed by others, a written statement indicating the date of

Repairs performed by Seller and provide Copies of receipts and statements of

seller prior to final verification of condition. (Ref: Residential Purchase Agreement

Form RPA-CA, page 4 item 10.)

MOLD, MILDEW, FUNGUS & Mold, mildew, fungus and other microbial organisms commonly occur in MICROBIAL ORGANISMS: areas that show evidence of or have the potential for leaking, moisture

intrusion and/or inadequate ventilation. The identification of the organisms is beyond the scope of the inspector. Any area or item exhibiting such conditions can be a health hazard to some people. If concerned about this possibility, we recommend further investigation be performed by a Certified Industrial Hygienist to determine if there exists an ongoing climate for incubation or microbial contamination and that steps be taken to eliminate this climate.

21

Page 22: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

M H I 1930-32 Anderson Lodi, CA 952425/1/2017

Carbon MonoxideRequires installation of approved carbon monoxide detectors in single-family dwellings by July 1, 2011, and for all other dwellings by 2013 if those dwellings contain a fossil fuel burning heater or appliance, fireplace, or an attached garage. Applies to rental property. Provides $100 penalty upon sale or transfer of noncompliant dwellings.Cal. Health & Safety Code § 17926 to 17926.2 – Regulation of Buildings Used for Human HabitationSmoke Detectors

The number and location of smoke alarms is specified in section 310.9.1.4 of the California Building Code. One smoke alarm should be placed on each floor in non-sleeping areas. In addition, one smoke alarm must be installed in each room where sleeping occurs and one smoke alarm should be located in each hallway that leads directly to sleeping rooms.

This report is the exclusive property of the inspection company and the client whose name appears herewith and its use by any unauthorized persons is prohibited.

PRODUCT RECALLS AND Product recalls and consumer product safety alerts are added almost SAFETY ALERTS: daily. If client is concerned about appliances or other items installed in the home

that may be on such lists, client may wish to visit the U.S. Consumer Protection Safety Commission (CPSC) web site http://www.cpsc.gov or www.recalls.com for further information. A basic home inspection does not include the identification or research for appliances and other items installed in the home that may be on the CPSC lists.

ENVIRONMENTAL HAZARDS Environmental hazards, materials or conditions, including, lead, asbestos

and OR MATERIALS: radon andnot limited to, toxic, reactive, combustible, corrosive contaminates,

wildfire and flood. Homes built before 1979 may have products in them that

contain some amounts of asbestos or lead. Determining the presence of these

products is beyond the scope of this report. An environmental survey is not part of

a home inspection, this service is available by contracting with an appropriate

specialist.

22

Page 23: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

a Miller-Klein Development, Inc. company

Client: Greg Smith

Property Address: 1930-32 Anderson Lodi, CA 95242

Report # and inspection date: 1930A 5/1/2017

23

Page 24: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

24

Page 25: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

25

Page 26: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

This is the last page of this report any pages printed after this page are

not a part of report.

M H I 1930-32 Anderson Lodi, CA 952421/0/190026

Page 27: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

27

Page 28: Confidential Inspection Report...M H I 1930-32 Anderson Lodi, CA 952425/1/2017 A non-invasive, limited visual inspection of the above-mentioned property was performed, at clients

28