conduits - hegler · raw material: pvc-u/p (flame-retar-dant) colour: grey (acc. to ral 7035)...
TRANSCRIPT
ElectricalConduits
EN Programme
Edition II/1
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:36 Uhr Seite 33
Economical and Environmentally Sound Pipe Systems Made of Thermoplastic Materials
Structural Engineering, BuildingConstruction and IndustrialConstruction
• conduit systems consisting of pliable plastic pipes
• conduit systems consisting of rigid plastic pipes for surface wiring
• conduit systems meeting highest fire protection requirements
• pliable and rigid conduit systems made of steel and aluminium for industrial installations
Special Applications
• flexible corrugated protective tubes for sanitary and heating engineering
• flexible and rigid tubes made of engineering plastics to be used for example in machine and apparatus construction, automotive industry and medical engineering
Civil Engineering
• waste water sewer pipe systems • storm water sewer pipe systems• drainage pipe systems for the
protection of structures• inspection manholes for subsoil
drainage systems• seepage systems for preclarified
waste water and storm water• drainage pipes for road construc-
tion and civil engineering purposes• cable ducting systems for under-
ground installation
Agricultural Drainage
• flexible drainage pipes• heating pipes for horticulture
Special machine construction
• extruder downstream equipment to produce corrugated and twin wall pipes for a great variety of applica-tions
HEGLER PLASTIK GMBH
Heglerstraße 8D-97714 Oerlenbach/UnterfrankenPhone: ++49 (0) 97 25 66-0Fax: ++49 (0) 97 25 66-115
Production and marketing of pipesystems and extruder downstreamequipment, R & D centre, head office
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:34 Uhr Seite 2
Contents
3
ELECTRICAL CONDUITS
HEGLERFLEX pages 4 - 7 pliable electrical conduits
HEGLERPLAST pages 8 - 9smooth rigid electrical conduits
STAPAFLEX page 10pliable armoured conduits made of steel
STAPA pages 12 - 13smooth rigid armoured conduits made of steel
HEGLER-ALU page 14smooth rigid conduits made of aluminium
Accessories for ELECTRICAL CONDUITS
HEGLERFLEX/HEGLERPLAST page 16
STAPAFLEX/STAPA page 17
HEGLER-ALU page 18
CABLE DUCTS
HEKAPLAST page 20structured-walled cable ducts made of PE-HD
HEKAPLAN/HEKAWELL page 21structured-walled cable ducts made of PVC-U
Accessories for CABLE DUCTS
HEKAPLAST page 22
HEKAPLAN page 23
HEKAWELL page 24
CLASSIFICATION page 26
NOMINAL DIAMETERS page 27
SYNOPTICAL TABLE pages 28 - 29
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:34 Uhr Seite 3
HEGLERFLEX-EYLF DIN EN 50086-2-2: classification 22322 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥10.5 ≥13.5 ≥17.4 ≥23.5 ≥30.1 ≥37.7 ≥50.1
Coil length (m) 100 100 50 50 25 25 25
Item No. 93100.. 16 20 25 32 40 50 63
Accessories grooved couplers, see page 16
HEGLERFLEX-EYLF
strength: light (320 N)impact: lightlower temperature range: -25 °Cupper temperature range: 105 °Cpliable
Raw material: PE/PP (halogen-free)Colour: orangeApplication: for surface and con-cealed wiring as well as for instal-lation in precast concrete
HEGLERFLEX-EYL DIN EN 50086-2-2: classification 22432 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥10.5 ≥13.5 ≥17.4 ≥23.5 ≥30.1 ≥37.7 ≥50.1
Coil length (m) 100 100 50 50 25 25 25
Item No. 93000.. 16 20 25 32 40 50 63
Accessories grooved couplers, see page 16
HEGLERFLEX-EYL
HEGLERFLEX
pliable electrical
conduits
Due to their special corrugated shapeand constant quality, HEGLERFLEXelectrical conduits meet all require-ments to allow easy and progressiveinstallation. The product is availablein a great variety of stiffnesses, raw
materials and mechanical propertiesto suit the different requirementsresulting from the way of constructionand degree of loading.
4
2
2
2
3
4
strength: light (320 N)impact: lightlower temperature range: -15 °Cupper temperature range: 90 °Cpliable
Raw material: PE/PP (flame-retar-dant)Colour: black with and withoutcoloured marking stripesApplication: for surface and con-cealed wiring as well as for instal-lation in precast concrete, cavitiesand false floors
2
2
2
3
2
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:34 Uhr Seite 4
HEGLERFLEX-EL DIN EN 50086-2-2: classification 22212 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥10.7 ≥14.1 ≥18.3 ≥24.3 ≥31.2 ≥39.6 ≥50.6
Coil length (m) 100 100 50 50 25 25 25
Item No. 92000.. 16 20 25 32 40 50 63
Accessories grooved couplers, see page 16
HEGLERFLEX-EL
5
HEGLERFLEX-ESPM DIN EN 50086-2-2: classification 33212 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥10.7 ≥13.0 ≥16.9 ≥21.4 ≥31.2 ≥39.6 ≥50.6
Coil length (m) 50 50 50 25 25 25 25
Item No. 92300.. 16 20 25 32 40 50 63
Accessories smooth couplers, see page 16
HEGLERFLEX-ESPM
strength: light (320 N)impact: lightlower temperature range: -5 °Cupper temperature range: 60 °Cpliable
Raw material: PVC-U (flame-retar-dant)Colour: white (acc. to RAL 1013)Application: for surface and con-cealed wiring as well as for instal-lation in cavities and false floors
2
2
2
1
2
strength: medium (750 N)impact: mediumlower temperature range: -5 °Cupper temperature range: 60 °Cpliable
Raw material: PVC-U/P (flame-retar-dant)Colour: grey (acc. to RAL 7035)Application: for installation in vibra-ted, heaped and tamped concrete aswell as in floor finish
3
3
2
1
2
HEGLERFLEX-ESPM 105 DIN EN 50086-2-2: classification 33333 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥10.5 ≥13.5 ≥17.4 ≥23.5 ≥30.1 ≥37.7 ≥50.1
Coil length (m) 50 50 50 25 25 25 25
Item No. 92500.. 16 20 25 32 40 50 63
Accessories grooved couplers, see page 16
HEGLERFLEX-ESPM 105
strength: medium (750 N)impact: mediumlower temperature range: -15 °Cupper temperature range: 105 °Cself-recovering
Raw material: special thermoplasticmaterial (flame-retardant)Colour: reddish brownApplication: for installation in vibra-ted, heaped and tamped concrete aswell as in floor finish where high re-sistance to thermal deformation isrequired
3
3
3
3
3
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:34 Uhr Seite 5
HEGLERFLEX-EYSPMH DIN EN 50086-2-2: classification 33232 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm)
Coil length (m) 50 50 50 25 25 25 25
Item No. 91200.. 16 20 25 32 40 50 63
Accessories grooved couplers, see page 16
HEGLERFLEX-EYSPMH
HEGLERFLEX-ELH DIN EN 50086-2-2: classification 23232 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥10.5 ≥13.5 ≥17.4 ≥23.5 ≥30.1 ≥37.7 ≥50.1
Coil length (m) 100 100 50 50 25 25 25
Item No. 91000.. 16 20 25 32 40 50 63
Accessories grooved couplers, see page 16
HEGLERFLEX-ELH
6
strength: light (320 N)impact: mediumlower temperature range: -5 °Cupper temperature range: 105 °Cpliable
Raw material: PP mod (halogen free,flame-retardant)Colour: blackApplication: for concealed and sur-face wiring as well as for installation incavities and false floors and precastconcrete for applications subject tostrict safety regulations
2
3
2
3
2
strength: medium (750 N)impact: mediumlower temperature range: -5 °Cupper temperature range: 105 °Cpliable
Raw material: special thermoplasticmaterial (halogen-free, flame-retar-dant)Colour: blackApplication: for installation in vibra-ted, heaped and tamped concrete aswell as in floor finish for applicationssubject to strict safety regulations
3
3
2
3
2
HEGLERFLEX-ESPS DIN EN 50086-2-2: classification 43212 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥10.7 ≥13.0 ≥16.9 ≥21.4 ≥31.2 ≥39.6 ≥50.6
Coil length (m) 50 50 50 25 25 25 25
Item No. 92400.. 16 20 25 32 40 50 63
Accessories smooth couplers, see page 16
HEGLERFLEX-ESPS
strength: heavy (1250 N)impact: mediumlower temperature range: -5 °Cupper temperature range: 60 °Cpliable
Raw material: PVC-U/P (flame-retar-dant)Colour: blackApplication: for installation in vibra-ted, heaped and tamped concrete aswell as in floor finish and for all appli-cations requiring high compressionstrength
4
3
2
1
2
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:34 Uhr Seite 6
7
HEGLERFLEX-EGL DIN EN 50086-2-2: classification 22412 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥10.5 ≥13.5 ≥17.8 ≥23.5 ≥30.1 ≥37.7 ≥50.1
Coil length (m) 50 100 50 50 25 25 25
Item No. 93400.. 16 20 25 32 40 50 63
Accessories smooth couplers, see page 16
HEGLERFLEX-EGL
strength: light (320 N)impact: lightlower temperature range: -25 °Cupper temperature range: 60 °Cpliable
Raw material: PE Colour: orangeApplication: for concealed and sur-face wiring
2
2
2
1
4
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:34 Uhr Seite 7
HEGLERPLAST-EPKM
HEGLERPLAST-EL DIN EN 50086-2-1: classification 22211 Nominal diameter DN 16 20 25
Outside diameter (mm) 16 20 25
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4
Inside diameter (mm) ≥13.7 ≥17.4 ≥22.1
Contents of bundle (m) 111 111 57
Item No. 97000.. 16 20 25
Accessories bends, couplers, clamps, see page 16
HEGLERPLAST-EL
HEGLERPLAST
smooth rigid
electrical conduits
HEGLERPLAST electrical conduits forsurface assembly where an impecca-ble appearance is required. Thesmooth PVC-U conduits in straightlengths are perfectly suitable for sur-face and concealed wiring and inconcrete construction. Only fewfastening points are necessary, which
makes an economy-priced installationpossible. All rigid HEGLERPLASTpipes are provided with integral coni-cal sockets, which offers furtheradvantages in assembly.HEGLERPLAST conduits are availablein a standard length of 3.00 m.
8
strength: light (320 N)impact: lightlower temperature range: -5 °Cupper temperature range: 60 °Crigid
Raw material: PVC-U (flame-retar-dant)Colour: grey (acc. to RAL 7035)Application: for surface wiring aswell as installation in cavities andfalse floors
2
2
1
1
2
HEGLERPLAST-EPKM DIN EN 50086-2-1: classification 33211 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥13.0 ≥16.9 ≥21.4 ≥27.8 ≥35.4 ≥44.3 ≥55.6
Contents of bundle (m) 111 111 57 57 21 21 21
Item No. 97100.. 16 20 25 32 40 50 63
Accessories bends, couplers, clamps, see page 16
strength: medium (750 N)impact: mediumlower temperature range: -5 °Cupper temperature range: 60 °Crigid
Raw material: PVC-U (flame-retar-dant)Colour: grey (acc. to RAL 7035)Application: for surface wiring aswell as installation in cavities andfalse floors and in concrete construc-tion
3
3
1
1
2
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:34 Uhr Seite 8
HEGLERPLAST-EPKMU DIN EN 50086-2-1: classification 33411 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥13.0 ≥16.9 ≥21.4 ≥27.8 ≥35.4 ≥44.3 ≥55.6
Contents of bundle (m) 57 57 57 21 21 21 21
Item No. 97200.. 16 20 25 32 40 50 63
Accessories bends, couplers, clamps, see page 16
HEGLERPLAST-EPKMU
HEGLERPLAST-EPKS DIN EN 50086-2-1 classification 43211 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥12.2 ≥15.8 ≥20.6 ≥26.6 ≥34.4 ≥43.2 ≥54.8
Contents of bundle (m) 57 57 57 21 21 21 21
Item No. 97300.. 16 20 25 32 40 50 63
Accessories bends, couplers, clamps, see page 16
HEGLERPLAST-EPKS
HEGLERPLAST-EPKMH DIN EN 50086-2-1: classification 33421 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥13.0 ≥16.9 ≥21.4 ≥27.8 ≥35.4 ≥44.3 ≥55.6
Contents of bundle (m) 111 111 57 57 21 21 21
Item No. 96000.. 16 20 25 32 40 50 63
Accessories bends, couplers, clamps, see page 16
HEGLERPLAST-EPKMH
9
strength: heavy (1250 N)impact: mediumlower temperature range: -5 °Cupper temperature range: 60 °Crigid
Raw material: PVC-U (flame-retar-dant)Colour: grey (acc. to RAL 7035)Application: for surface wiring aswell as for installation in vibrated,heaped and tamped concrete
4
3
1
1
2
strength: medium (750 N)impact: mediumlower temperature range: -25 °Cupper temperature range: 60 °Crigid
Raw material: PVC-U (UV-stabilized,flame-retardant)Colour: whiteApplication: for surface wiring out ofdoors
3
3
1
1
4
strength: medium (750 N)impact: mediumlower temperature range: -25 °Cupper temperature range: 90 °Crigid
Raw material: PPO (halogen-free,flame-retardant)Colour: grey (acc. to RAL 7035)Application: for surface wiring aswell as for installation in vibrated,heaped and tamped concrete forapplications subject to strict safetyregulations
3
3
1
2
4
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:34 Uhr Seite 9
STAPAFLEX-EPY DIN EN 50086-2-2: classification 44412 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥10.7 ≥14.1 ≥18.3 ≥24.3 ≥31.2 ≥39.6 ≥50.6
Coil length (m) 25 25 25 25 25 25 25
Item No. 90100.. 16 20 25 32 40 50 63
Accessories threaded couplers, see page 17
STAPAFLEX-EPY
STAPAFLEX-EP DIN EN 50086-2-2: classification 44562 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥10.7 ≥14.1 ≥18.3 ≥24.3 ≥31.2 ≥39.6 ≥50.6
Coil length (m) 25 25 25 25 25 25 25
Item No. 90000.. 16 20 25 32 40 50 63
Accessories threaded couplers, see page 17
STAPAFLEX-EP
STAPAFLEX
pliable armouredconduits made ofsteel
Pliable armoured steel conduits aremade of a high-quality lead-coatedsheet iron in multi-layer design.Thanks to their narrow grooving, theyare extraordinarily flexible.Depending on the type of pipe, thereare layers of impregnated paper inbetween the iron sheet to providemoisture-proof insulation. One pipe
design is covered with a PVC-P coatfor protection against corrosion. Bythis, these pipes offer protectionagainst moisture, aggressive dampsand liquids as well as dangerous con-tact electricity. All types of armouredsteel conduits are suited for highmechanical loads. The pipes withoutcoating are resistant to temperaturesof up to 250 °C. They are light inweight and allow economical installa-tion with no need of special tooling orbends. Fixing is easily done by meansof clamps. The narrow grooving suitsall standardized steel pipe connectorsand provides tensile connection.Threading is not necessary.
10
strength: heavy (1250 N)impact: heavylower temperature range: -45 °Cupper temperature range: 250 °Cpliable
Raw material: lead-coated sheetiron, with layers of insulating paper inbetweenApplication: for installation in ma-chine construction, manufacture ofapparatus and vehicles as well as inmelted asphalt
4
4
2
6
5
strength: heavy (1250 N)impact: heavylower temperature range: -25 °Cupper temperature range: 60 °Cpliable
Raw material: lead-coated sheetiron, with layers of insulating paper inbetween and covered with a plasticcoating for protection against corro-sionApplication: for installation in ma-chine construction and manufactureof apparatus and vehicles
4
4
2
1
4
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:34 Uhr Seite 10
11
ELTEFA show at Stuttgart
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:34 Uhr Seite 11
STAPA-EGs DIN EN 50086-2-1: classification 55561Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥13.0 ≥16.8 ≥21.8 ≥28.8 ≥36.8 ≥46.8 ≥59.4
Contents of bundle (m) 30 30 30 21 15 15 15
Item No. 95100.. 16 20 25 32 40 50 63
Accessories threaded bends, threaded couplers, see page 17
STAPA-EGs
STAPA-ESs DIN EN 50086-2-1: classification 44561 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥14.0 ≥18.0 ≥22.6 ≥30.6 ≥37.6 ≥47.6 ≥60.0
Contents of bundle (m) 30 30 30 21 15 15 15
Item No. 95000.. 16 20 25 32 40 50 63
Accessories bends, couplers, see page 17
STAPA-ESs
STAPA
smooth rigid ar-moured conduitsmade of steel
Armoured steel conduits made of rolled mild steel are suitable for highcompression and temperature loadsand for highest mechanical demands. STAPA pipes are available in a stan-dard length of 3.00 m.
12
strength: heavy (1250 N)impact: heavylower temperature range: -45 °Cupper temperature range: 250 °Crigid
Raw material: mild steel, rolled, bent,high-frequency welded, with stove-enamellingApplication: for applications wherehigh temperatures occur and highestmechanical protection is required
4
4
1
6
5
strength: very heavy (4000 N)impact: very heavylower temperature range: -45 °Cupper temperature range: 250 °Crigid
Raw material: mild steel, rolled, bent,high-frequency welded, with stove-enamellingApplication: for applications wherehigh temperatures occur and highestmechanical protection is required
5
5
1
6
5
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 12
STAPA-EGv DIN EN 50086-2-1: classification 55571Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥13.0 ≥16.8 ≥21.8 ≥28.8 ≥36.8 ≥46.8 ≥59.4
Contents of bundle (m) 30 30 30 21 15 15 15
Item No. 95101.. 16 20 25 32 40 50 63
Accessories threaded bends, threaded couplers, see page 17
STAPA-EGv
STAPA-ESv DIN EN 50086-2-1: classification 44571Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥14.0 ≥18.0 ≥22.6 ≥30.6 ≥37.6 ≥47.6 ≥60.0
Contents of bundle (m) 30 30 30 21 15 15 15
Item No. 95001.. 16 20 25 32 40 50 63
Accessories bends, couplers, see page 17
STAPA-ESv
13
strength: heavy (1250 N)impact: heavylower temperature range: -45 °Cupper temperature range: 400 °Crigid
Raw material: mild steel, rolled, bent,high-frequency welded and galva-nizedApplication: for all applications wherehigh temperatures occur and highestmechanical protection and corrosionresistance are required
4
4
1
7
5
strength: very heavy (4000 N)impact: very heavylower temperature range: -45 °Cupper temperature range: 400 °Crigid
Raw material: mild steel, rolled, bent,high-frequency welded and galva-nizedApplication: for applications wherehigh temperatures occur and highestmechanical protection and corrosionresistance are required
5
5
1
7
5
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 13
HEGLER ALU-EG DIN EN 50086-2-1: classification 55561 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥12.7 ≥16.5 ≥21.5 ≥28.4 ≥36.2 ≥46.2 ≥58.8
Contents of bundle (m) 30 30 30 30 15 15 15
Item No. 95300.. 16 20 25 32 40 50 63
Accessories threaded bends, threaded couplers, clamps, see page 18
HEGLER ALU-EG*
HEGLER ALU-ES DIN EN 50086-2-1: classification 44561 Nominal diameter DN 16 20 25 32 40 50 63
Outside diameter (mm) 16 20 25 32 40 50 63
Permissible tolerances (mm) 0/-0.3 0/-0.3 0/-0.4 0/-0.4 0/-0.4 0/-0.5 0/-0.6
Inside diameter (mm) ≥14.0 ≥18.0 ≥22.6 ≥29.2 ≥37.2 ≥47.0 ≥59.4
Contents of bundle (m) 30 30 30 30 15 15 15
Item No. 95200.. 16 20 25 32 40 50 63
Accessories bends, couplers, clamps, see page 18
HEGLER ALU-ES
HEGLER-ALU
smooth rigid conduits made of aluminium
Aluminium conduits for highestmechanical requirements, easy toinstall and corrosion resistant.
14
strength: heavy (1250 N)impact: heavylower temperature range: -45 °Cupper temperature range: 250 °Crigid
Raw material: aluminiumApplication: for applications whereaggressive conditions affect the pro-duct, e. g. chemical industry, shipconstruction etc.
4
4
1
6
5
strength: very heavy (4000 N)impact: very heavylower temperature range: -45 °Cupper temperature range: 250 °Crigid
Raw material: aluminiumApplication: for applications whereaggressive conditions affect the pro-duct, e. g. chemical industry, shipconstruction etc.
5
* in preparation
5
1
6
5
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 14
15
Light + Building show at Frankfurt
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 15
Bend belled at one end,grey, of PVC-U forHEGLERPLAST-EPKM and EPKS, ofPPO for HEGLER-PLAST-EPKMH
Grooved couplergrey for HEGLER-FLEX-EL, black forHEGLERFLEX-EYL,EYLF, ESMP 105,ELH and EYSMPH
Smooth couplerwith inside lockingcam, grey, of PVC-Ufor HEGLERPLAST-EPKM and EPKS aswell as HEGLERFLEX-ESPM, ESPS andEGL, of PPO forHEGLERPLAST-EPKMH
Bendbelled at one end,grey, of PVC-U forHEGLERPLAST-ELand black, of specialthermoplastic materialfor HEGLERPLAST-EPKMU
Clampssuitable for stringing,grey for HEGLER-PLAST-EPKM, EPKS,EL; of PPO forHEGLERPLAST-EPKMH and black,ofspecial thermoplasticmaterial for HEGLER-PLAST-EPKMU
Smooth couplerwith inside lockingcam, grey, of PVC-Ufor HEGLERPLAST-EL and black, of spe-cial thermoplasticmaterial for HEGLER-PLAST-EPKMU
Accessories: HEGLERFLEX and HEGLERPLAST
16
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 50 50 50 50 10 10 10
EPKM, EPKSItem No. 98110.. 16 20 25 32 40 50 63
EPKMHItem No. 98410.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 100 100 50 50 25 25 10
ELItem No. 98600.. 16 20 25 32 40 50 63
EYL, EYLF, ESPM 105, ELH, EYSPMHItem No. 98700.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 100 100 50 50 25 25 10
EPKM, EPKS, ESPM, ESPS, EGLItem No. 98100.. 16 20 25 32 40 50 63
EPKMHItem No. 98400.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 50 50 50 50 10 10 10
ELItem No. 98010.. 16 20 25 32 40 50 63
EPKMUItem No. 98111.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 100 100 100 50 25 25 10
EPKM, EPKS, ELItem No. 98120.. 16 20 25 32 40 50 63
EPKMHItem No. 98420.. 16 20 25 32 40 50 63
EPKMUItem No. 98121.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 100 100 50 50 25 25 10
ELItem No. 98000.. 16 20 25 32 40 50 63
EPKMUItem No. 98101.. 16 20 25 32 40 50 63
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 16
Couplerpush-fit type, for rigidarmoured steel condu-its STAPA-ESs andESv
Couplerthreaded, for pliableand rigid armouredsteel conduits STAPA-FLEX-EP, EPY andSTAPA-EGs and EGv
Bend threaded, for rigidarmoured steel condu-its STAPA-EGs andEGv
Bendpush-fit type, for rigidarmoured steel condu-its STAPA-ESs andESv
Accessories: STAPAFLEX and STAPA
17
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 25 50 50 50 25 10 5
EP, EPY, EGs Item No. 99700.. 16 20 25 32 40 50 63
EP, EPY, EGv Item No. 99701.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 25 50 50 50 25 10 5
ESs Item No. 99800.. 16 20 25 32 40 50 63
ESv Item No. 99801.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 15 25 25 20 15 5 3
EGsItem No. 99710.. 16 20 25 32 40 50 63
EGv Item No. 99711.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 15 25 25 20 15 5 3
ESs Item No. 99810.. 16 20 25 32 40 50 63
ESv Item No. 99811.. 16 20 25 32 40 50 63
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 17
Couplerpush-fit type, for alu-minium conduits ALU-ES
Couplerthreaded, for alumi-nium conduits ALU-EG
Bendthreaded, for alumi-nium conduits ALU-EG
Bendpush-fit type, for alu-minium conduits ALU-ES
Accessories: HEGLER-ALU
Clampfor aluminium conduitsALU-EG and ALU-ES
Bolted clamp for aluminium conduitsALU-EG and ALU-ES
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 50 50 50 50 25 20 20
Item No. 99500.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 50 50 50 50 20 20 20
Item No. 99600.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 10 10 10 10 10 10 10
Item No. 99510.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 10 10 10 10 10 10 10
Item No. 99610.. 16 20 25 32 40 50 63
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 50 50 50 25 20 20 20
Item No. 99621.. 16 20 25 32 40 50 63
18
DN 16 20 25 32 40 50 63
Bag quantity (pcs.) 50 50 50 50 20 20 20
Item No. 99620.. 16 20 25 32 40 50 63
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 18
19
ELTEC show at Nürnberg
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 19
Pipe in twin wall design with a corru-gated outside and smooth inside, withpull wire, pliable. Resistant to tempe-ratures from –40 to 105 °C.
Raw material: PEStandard colour: blackAlternative colours: on request
Application:as cable ducts underground and inconcrete; suitable to withstand trafficloads. Due to its extraordinary flexibili-ty in longitudinal direction, HEKA-PLAST-R is also suitable for difficultcable installations, such as aroundfoundations or other obstacles.
HEKAPLAST-R
Pipe in twin wall design with a corruga-ted outside and smooth inside; stan-dard length: 6.00 m. Resistant to temperatures from –40 to 105 °C.
Raw material: PEStandard colour: blackAlternative colours: on request
Quality:a) general purpose grade andb) grade to DIN EN 50086-2-4.Application:as cable duct underground and inconcrete; suitable to withstand trafficloads.
HEKAPLAST-S
HEKAPLAST
cable protectionand cable ductingpipes
It is always a problem to replace or toextend ducting systems under trafficareas, no matter whether in publicroads or industrial plants. Digged-uptraffic areas handicap activities, annoylocal residents, cause considerablecosts and leave a ”mended” surface.Cable ducts prevent all this.
They should be installed wherever anincreasing need of cables has to beconsidered.
20
HEKAPLAST-R DN 40 50 63 75 90 110 125 140 160 200Outside diameter (mm) 40 50 63 75 90 110 125 140 160 200
Tolerances (mm) + 0.8 + 1.0 + 1.2 + 1.4 + 1.7 + 2.0 + 2.3 + 2.6 + 2.9 + 3.6
Inside diameter (mm) 32.0 39.5 51.0 62.0 76.0 95.0 107.0 120.5 139.0 173.0
Tolerances (mm) ± 0.5 ± 0.6 ± 0.7 ± 0.8 ± 0.9 ± 1.1 ± 1.3 ± 1.4 ± 1.6 ± 2.0
Coil length (m) 50 50 50 50 50 50 50 50 50 50
Item No. 7629.. 004 005 006 007 009 011 013 014 016 020
Accessories couplers, bends, profiled sealing rings, see page 22
HEKAPLAST-S DN 63 75 90 110 125 140 160 200Outside diameter (mm) 63 75 90 110 125 140 160 200
Tolerances (mm) + 1.2 + 1.4 + 1.7 + 2.0 + 2.3 + 2.6 + 2.9 + 3.6
Inside diameter (mm) 51.0 62.0 76.0 95.0 107.0 120.5 139.0 173.0
Tolerances (mm) ± 0.7 ± 0.8 ± 0.9 ± 1.1 ± 1.3 ± 1.4 ± 1.6 ± 2.0
Contents of stillage (m) 918 1260 720 780 612 360 390 210
Item No. 7621.. 063 075 090 110 125 140 160 200
Accessories couplers, bends, profiled sealing rings, see page 22
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 20
Pipe in twin wall design, corrugatedoutside and smooth inside, with inte-gral socket; standard length: 6.00 m.Resistant to temperatures from –5 to60 °C.
Raw material: PVC-UColour: black
Flexible corrugated cable duct, com-pression and impact resistant acc. toDIN 1187. Resistant to temperaturesfrom –5 to 60 °C.
Raw material: PVC-UColour: yellow
Application:An economy-priced alternative forsubordinate jobs and jobs with infe-rior loading.
HEKAWELL
Application:Particularly suited for applicationslike tunnel or concrete constructionin which the pipes are installed insolid bundles and cast in concrete.
HEKAPLAN
HEKAPLANHEKAWELL
Cables often have to be installed inbundles, like in structural engineering,industrial buildings or civil engineer-ing. Protection pipes with integralsockets are a very good option to al-low multiple-way ducting in concrete.
HEKAWELL DN 50 65 80 100 125 160 200Outside diameter (mm) 50 65 80 100 125 160 200
Inside diameter (mm) 44 58 71.5 91 115 144 182
Coil length (m) 50 50 50 50 50 50 50
Item No. 7495.. 050 065 080 100 125 160 200
Accessories see page 24
21
HEKAPLAN DN 110/100 165/150Outside diameter (mm) 110 163
Inside diameter (mm) 100.5 151.0
Insert depth or depth of coupler (mm) 100 120
Push-fit coupler/outside diameter (mm) 114 168
Contents of stillage (m) 780 390
Item No. 7615.. 110 165
Accessories couplers, bends, profiled sealing rings, see page 23
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 21
Bend 45°r = 1.0 m, shapedfrom HEKAPLASTpipe, black
Couplerwith locking cam (w. l.c.) or without lockingcam (wo. l. c.), madeof PP, black
Bend 90°r = 1.0 m, shapedfrom HEKAPLASTpipe, black
End capmade of PE, natural-coloured
Spacer
Profiled sealing ringmade of elastomericmaterials
Accessories: cable ducts HEKAPLAST
22
DN 40 50 63 75 90 110 125 140 160 200
Bag quantity (pcs.) 1 1 1 100 50 75 60 45 36 20
w. l. c.Item No. 7710... 004 005 007 008 009 011 013 014 016 020
wo. l. c.Item No. 7710... 108 109 111 113 114 116 120
DN 75 90 110 125 140 160 200
Bag quantity (pcs.) 1 1 1 1 1 1 1
Item No. 7710... 208 209 211 213 214 216 220
DN 75 90 110 125 140 160 200
Bag quantity (pcs.) 1 1 1 1 1 1 1
Item No. 7710... 408 409 411 413 414 416 420
DN 40 50 63 75 90 110 125 140 160 200
Bag quantity (pcs.) 50 50 50 50 50 50 50 25 25 25
Item No. 7720... 204 205 207 208 209 211 213 214 216 220
DN 40 50 63 75 90 110 125 140 160 200
Bag quantity (pcs.) 100 100 100 100 100 200 50 25 25 25
Item No. 7720... 304 305 307 308 309 311 313 314 316 320
DN 50 63 75 90 110 125 140 160 200
available in 2-/4-/6-/8-strand version and one- or two-sided version
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 22
Bend 45°r = 1.0 m, shapedfrom HEKAPLAN pipe,black
Couplermade of PVC-U, black
Bend 90°r = 1.0 m, shapedfrom HEKAPLAN pipe,black
End capmade of PVC-U, black
Profiled sealing ringmade of elastomericmaterials
Accessories: cable ducts HEKAPLAN
23
DN 110/100 165/150
Bag quantity (pcs.) 75 1
Item No. 7700... 011 015
DN 110/100 165/150
Bag quantity (pcs.) 1 1
Item No. 7701... 011 015
DN 110/100 165/150
Bag quantity (pcs.) 100 100
Item No. 7704... 011 015
DN 110/100 165/150
Bag quantity (pcs.) 1 1
Item No. 7702... 011 015
DN 110/100 165/150
Bag quantity (pcs.) 1 1
Item No. 7703... 011 015
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 23
End capmade of PVC-U, black
Couplermade of PVC-U,yellow
HRH round hoods withsuspension fastening
PL cover plates
Accessories: cable ducts HEKAWELL
24
DN 50 65 80 100 125 160 200
Bag quantity (pcs.) 100 100 100 50 50 15 10
screw couplerItem No. 7774... – – – 010 012 016 020
sleeveItem No. 7774... 005 006 008 – – – –
DN 50 65 80 100 125 160 200
Bag quantity (pcs.) 200 100 100 100 50 50 1
Item No. 7774... 105 106 108 110 112 116 120
Type (width in mm) 40 50 60 80 100
Bag quantity (m) 1000 1000 1000 500 500
Item No. 7611... 040 050 060 080 100
DN 120 180
Bag quantity (m) 1000 1000
Item No. 7612... 120 180
Accessories: cover hoods and plates HEKADUKT
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 24
25
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 25
26
Resistance to flame propagation
orange flame propagating
any colour non-flame propagatingapart from
orange, yellow and
red
Colour of pipe
Classification
To allow the European countries to"grow together", impediments totrade are to be reduced. The harmo-nisation of national standards intointernational ones (CEN and CENE-LEC) comes up to this politicalrequest.
In the field of electrical conduits,several standards have been pre-pared by CENELEC in order to guarantee a uniform product quality in Europe. So there are now standard-ized nominal diameter series insteadof nominal diameters differing fromcountry to country.
In contrast to the so far inch system,these diameters are based on metricmeasurements. Nominal diametersare now based on the outside diame-ters and correspond to the followingDN series: DN 16, DN 20, DN 25, DN 32, DN 40, DN 50 and DN 63.The following table shows the systemof the new standards:
The new standards also include different specifications regarding designation and marking. The letters
have been turned into a numericalcode, the meaning of which can betaken from the following table.
Classification Code for Properties Claimed for a Conduit System
Marking of pipe, code No.:
No. of DIN standard Title
DIN EN Conduit Systems for Electrical Installations50086-1 Part 1: General Requirements
DIN EN Conduit Systems for Electrical Installations50086-2-1 Part 2-1: Particular Requirements for Rigid Conduit Systems
DIN EN Conduit Systems for Electrical Installations50086-2-2 Part 2-2: Particular Requirements for Pliable Conduit Systems
DIN EN Conduit Systems for Electrical Installations50086-2-3 Part 2-3: Particular Requirements for Flexible Conduit Systems
DIN EN Conduit Systems for Electrical Installations50086-2-4 Part 2-4: Particular Requirements for Conduit Systems Buried Underground
DIN EN Electrical conduits60423 Outside Diameters of Electrical conduits and Threads for Electrical conduits
and Their Accessories
Example: light weight pipe with light impact re-sistance, temperature resistant from –5 °C up to +60 °C, non-flame propagating.
1st figure – resistance to compression
1 very light compression force 125 N
2 light compression force 320 N
3 medium compression force 750 N
4 heavy compression force 1250 N
5 very heavy compression force 4000 N
2 2
2nd figure – resistance to impact
1 very light falling energy 0.5 kg/100 mm
2 light falling energy 1.0 kg/100 mm
3 medium falling energy 2.0 kg/100 mm
4 heavy falling energy 2.0 kg/300 mm
5 very heavy falling energy 6.8 kg/300 mm
3rd figure – lower temperature range
1 + 5 °C transport, perm. application, installation
2 – 5 °C transport, perm. application, installation
3 –15°C transport, perm. application, installation
4 –25°C transport, perm. application, installation
5 –45°C transport, perm. application, installation
2 1
4th figure – upper temperature range
1 60 °C transport, perm. application, installation
2 90 °C transport, perm. application, installation
3 105 °C transport, perm. application, installation
4 120 °C transport, perm. application, installation
5 150 °C transport, perm. application, installation
6 250 °C transport, perm. application, installation
7 400 °C transport, perm. application, installation
5th figure – resistance to bending
1 rigid acc. to EN 50086-2-1
2 pliable acc. to EN 50086-2-2
3 pliable, self-recovering EN 50086-2-2
4 flexible acc. to EN 50086-2-3
2
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 26
27
Nominal Diameters
The new DIN EN 50086-1
In the new EN standard, nominal dia-meters (DN) are defined differently!The new nominal diameters refer tothe real outside diameters. For exam-
ple, a pipe defined as DN 25 now hasan outside diameter of 25 mm, whilepreviously the nominal diametersreferred to inside diameters.
63
50
40
32
25
20
16
DN 9 11 13,5 16 19 21/23 29 36 42 48
New
no
min
al d
iam
eter
s as
per
EN
Previous definition of types (previous nominal diameters)
The table below shows how the new nominal diameters (DN) compare with the previous nominal diameters (DN)
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 27
Product Range, Product Data and Applications
28
HEGLERFLEXpliable electricalconduits
HEGLERPLASTsmooth rigidelectrical condu-its
STAPAFLEXpliable armouredsteel conduits
STAPAsmooth rigidarmoured steelconduits
HEGLER-ALUsmooth rigid alu-minium conduits
Cable ducts
Product group Short description of product Product name DN (mm) Colour Raw material Pipe Standard/ test geometry regulations
electrical conduit, pliable, corrugated, HEGLERFLEX-EYL 16 - 63 orange PE/PP corrugated DIN EN 50086-2-2/for light duty VDE 0605 Teil 2-2
electrical conduit, pliable, corrugated, HEGLERFLEX- 16 - 63 black PE/PP mod corrugated DIN EN 50086-2-2/for light duty, flame-retardant EYLF VDE 0605 Teil 2-2
electrical conduit, pliable, corrugated, for HEGLERFLEX-EL 16 - 63 RAL 1013 PVC-U corrugated DIN EN 50086-2-2/light duty, flame-retardant white VDE 0605 Teil 2-2
electrical conduit, pliable, corrugated, for HEGLERFLEX- 16 - 63 RAL 7035 PVC-U with corrugated ins. DIN EN 50086-2-2/medium duty, flame-retardant ESPM grey PVC-P coat smooth outs. VDE 0605 Teil 2-2
electrical conduit, self-recovering, corru- HEGLERFLEX- 16 - 63 reddish special thermo- corrugated DIN EN 50086-2-2/gated, for medium duty, ESPM 105 brown plastic material VDE 0605 Teil 2-2flame-retardant
electrical conduit, pliable, corrugated, for HEGLERFLEX- 16 - 63 black PVC-U with corrugated ins. DIN EN 50086-2-2/heavy duty, flame-retardant ESPS PVC-P coat smooth outs. VDE 0605 Teil 2-2
electrical conduit, pliable, corrugated, HEGLERFLEX-ELH 16 - 63 RAL 7035 PP mod corrugated DIN EN 50086-2-2/for light duty, halogen-free, flame-retardant grey VDE 0605 Teil 2-2
electrical conduit, pliable, corrugated, HEGLERFLEX- 16 - 63 black special thermo- corrugated ins. DIN EN 50086-2-2/for medium duty, halogen-free, EYSPMH plastic material smooth outs. VDE 0605 Teil 2-2flame-retardant
electrical conduit, pliable, smooth, HEGLERFLEX-EGL 16 - 63 orange PE smooth DIN EN 50086-2-2/for light duty VDE 0605 Teil 2-2
electrical conduit, smooth, rigid, for light HEGLERPLAST-EL 16 - 25 RAL 7035 PVC-U smooth DIN EN 50086-2-1/duty, flame-retardant grey VDE 0605 Teil 2-1
electrical conduit, smooth, rigid, for HEGLERPLAST- 16 - 63 RAL 7035 PVC-U smooth DIN EN 50086-2-1/medium duty, flame-retardant EPKM grey VDE 0605 Teil 2-1
electrical conduit, smooth, rigid, for heavy HEGLERPLAST- 16 - 63 RAL 7035 PVC-U smooth DIN EN 50086-2-1/duty, flame-retardant EPKS grey VDE 0605 Teil 2-1
electrical conduit, smooth, rigid, for HEGLERPLAST- 16 - 63 white PVC-U smooth DIN EN 50086-2-1/medium duty, flame-retardant, UV-stabilized, EPKMU VDE 0605 Teil 2-1impact resistant
electrical conduit, smooth, rigid, HEGLERPLAST- 16 - 63 RAL 7035 PPO smooth DIN EN 50086-2-1/for medium duty, flame-retardant, EPKMH grey VDE 0605 Teil 2-1halogen-free
armoured steel conduit, pliable, STAPAFLEX-EP 16 - 63 sheet iron, lea- grooved DIN EN 50086-2-2/for heavy duty ded, with paper VDE 0605 Teil 2-2
layers
armoured steel conduit, pliable, for STAPAFLEX-EPY 16 - 63 sheet iron, lea- corrugated ins. DIN EN 50086-2-2/heavy duty, corrosion resistant ded, with paper smooth outs. VDE 0605 Teil 2-2by PVC-P coating layers and
PVC-P coating
armoured steel conduit, rigid, STAPA-ESs 16 - 63 black steel smooth DIN EN 50086-2-1/smooth, for heavy duty VDE 0605 Teil 2-1
STAPA-EGs 16 - 63 black steel smooth DIN EN 50086-2-1/VDE 0605 Teil 2-1
STAPA-ESv 16 - 63 galvanized steel smooth DIN EN 50086-2-1/VDE 0605 Teil 2-1
STAPA-EGv 16 - 63 galvanized steel smooth DIN EN 50086-2-1/VDE 0605 Teil 2-1
aluminium conduit, smooth, rigid, ALU-ES 16 - 63 aluminium smooth DIN EN 50086-2-1/for heavy duty VDE 0605 Teil 2-1
aluminium conduit, smooth, rigid, for ALU-EG 16 - 63 aluminium smooth DIN EN 50086-2-1/heavy duty VDE 0605 Teil 2-1
twin wall pipe, corrugated HEKAPLAST-S 63 - 200 black PE-HD DIN EN 50086-2-4/outside, smooth inside, for heavy special VDE 0605 Teil 2-4duty colours
HEKAPLAST-R 40 - 200 black PE DIN EN 50086-2-4/sp. colours VDE 0605 Teil 2-4
twin wall pipe, corrugated outside, HEKAPLAN 110/100 black PVC-Usmooth inside, for heavy duty, 165/150flame-retardant
plastic pipe, flexible, corrugated, HEKAWELL 50 - 200 yellow PVC-U corrugated DIN 1187for light duty, flame-retardant
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 28
29
Cla
ssif
icat
ion
Su
rfac
ein
stal
lati
on
Co
nce
aled
inst
alla
tio
n
Inst
alla
tio
n in
h
eap
ed c
on
cret
e
Inst
alla
tio
n in
vib
rate
d c
on
cret
e
Inst
alla
tio
n in
ta
mp
ed c
on
cret
e
Inst
alla
tion
in
bit
um
ino
us
mat
eria
l
Inst
alla
tio
n in
m
elte
d a
sph
alt
Inst
alla
tio
n in
flo
or
fin
ish
Inst
alla
tion
in p
refa
bri
-ca
ted
co
ncr
ete
par
ts
Inst
alla
tio
n in
wo
od
en
and
pref
abri
cate
d pa
rts
and
in f
alse
flo
ors
Mac
hin
e an
d a
pp
ara-
tu
s in
stal
lati
on
Veh
icle
an
d
wag
on
inst
alla
tio
n
Su
bso
il in
stal
lati
on
Tem
per
atu
rera
ng
e fo
r u
se
see
pag
e
22432 O O O -25 to 105 °C 4
22322 O O O O O -15 to 90 °C 4
22212 O O -5 to 60 °C 5
33212 O O O O O O O O O O -5 to 60 °C 5
33333 O O O O O -15 to 105 °C 5
43212 O O O O O O O O O O -5 to 60 °C 6
23232 O O O O O O -5 to 105 °C 6
33232 O O O O O O O O O -5 to 105 °C 6
22412 O O O -25 to 60 °C 7
22211 O O O O -5 to 60 °C 8
33211 O O O O O O O O O -5 to 60 °C 8
43211 O O O O O O O O O -5 to 60 °C 9
33411 O O O O O O O O O -25 to 60 °C 9
33421 O O O O O O O O O O -25 to 90 °C 9
44562 O O O O O O O O O O -45 to 250 °C 10
44412 O O O O O O O O O O -25 to 60 °C 10
44561 O O O O O O O O O O -45 to 250 °C 12
55561 O O O O O O O O O O -45 to 250 °C 12
44571 O O O O O O O O O O -45 to 400 °C 13
55571 O O O O O O O O O O -45 to 400 °C 13
O O O O O O O O O O O 14
O O O O O O O O O O O 14
O O O -40 to 105 °C 20
O O O -40 to 105 °C 20
O O O -5 to 60 °C 21
O O O -5 to 60 °C 21
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 29
30
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 30
31
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:35 Uhr Seite 31
HEGLER PLASTIK GMBH · D-97714 Oerlenbach/Unterfranken
Phone ++49 (0) 97 25 66-0 · Fax ++49 (0) 97 25 66-115
Edition II/1
E-Rohr-Katalog_engl_neu.qxd 19.06.2006 12:36 Uhr Seite 32