conductor supported platforms - gmc deepwatergmcdeepwater.com/wp-content/uploads/2017/02/gmc...•...

2
Reliable Connected Technology Solutions! CONDUCTOR SUPPORTED PLATFORMS Marginal shallow-water developments have led to a growing demand for cost efficient wellhead platforms, which enable increased production capacity within existing field infrastructure. Wellhead platforms, or minimum facilities platforms (MFPs), typically house the surface wellheads, trees, and manifolds, but do not include extensive process or separation facilities. Conductors The conductors provide structural support to the topsides through axial compression and bending resistance, and support the well casings, wellhead, and surface tree. The total conductor length is defined by the water depth at the platform, the topsides elevation, and the foundation piling depth. The typical diameter of the conductor used to sup- port the platform is 30” or 36”, with thicknesses ranging from 1” to 2” maximum. High fatigue snap-together Mechanical Connectors are increasingly being use for the conductor supported platforms. GMC’s Low Cost Strategy GMC is experienced in working on behalf of operators providing best in class low cost field development solutions. GMC can reduce the project costs by selecting concept and partners to deliver turnkey projects. Working with the operator and GMC’s industry partners to develop the optimum solution for the client (Lowest cost, fastest time to first oil, best in class design.) GMC can act as “operators Project Management and Engineering team” to deliver the turnkey project with an integrated proven contracting strategy, on time and within budget. Experience & Innovation in Tubular Connection Technology from Surface to Seabed Minimum Facilities Platform Conductors Awaiting Platform Installation Photo courtesy of Aquaterra Energy. Photo courtesy of 2H Offshore.

Upload: others

Post on 07-Apr-2020

4 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: CONDUCTOR SUPPORTED PLATFORMS - GMC Deepwatergmcdeepwater.com/wp-content/uploads/2017/02/gmc...• The total conductor length is defined by the water depth at the platform, the topsides

Reliable Connected Technology Solutions!

CONDUCTOR SUPPORTED

PLATFORMS

Marginal shallow-water developments have led to a growing demand for cost efficient wellhead platforms, which enable increased production capacity within existing field infrastructure.

Wellhead platforms, or minimum facilities platforms (MFPs), typically house the surface wellheads, trees, and manifolds, but do not include extensive process or separation facilities.

Conductors

• The conductors provide structural support to the topsides through axial compression and bending resistance, and support the well casings, wellhead, and surface tree.

• The total conductor length is defined by the water depth at the platform, the topsides elevation, and the foundation piling depth.

• The typical diameter of the conductor used to sup-port the platform is 30” or 36”, with thicknesses ranging from 1” to 2” maximum.

High fatigue snap-together Mechanical Connectors are increasingly being use for the conductor supported platforms.

GMC’s Low Cost Strategy

GMC is experienced in working on behalf of operators providing best in class low cost field development solutions.

GMC can reduce the project costs by selecting concept and partners to deliver turnkey projects.

Working with the operator and GMC’s industry partners to develop the optimum solution for the client (Lowest cost, fastest time to first oil, best in class design.)

GMC can act as “operators Project Management and Engineering team” to deliver the turnkey project with an integrated proven contracting strategy, on time and within budget.

Experience & Innovation in Tubular Connection Technology from Surface to Seabed

Minimum Facilities Platform

Conductors Awaiting Platform Installation

Photo courtesy of Aquaterra Energy.

Photo courtesy of 2H Offshore.

Page 2: CONDUCTOR SUPPORTED PLATFORMS - GMC Deepwatergmcdeepwater.com/wp-content/uploads/2017/02/gmc...• The total conductor length is defined by the water depth at the platform, the topsides

For more information, visit www.gmcdeepwater.com, or contact [email protected]

GMC Limited © 2017 | All Rights Reserved V3:02/17

GMC Mechanical Connectors

Due to the dynamic loading on the conductors, fatigue enhanced connector designs are usually preferred for increased fatigue life of the conductors above the mudline.

As of January 2010, the GMC Mechanical Connector is the first mechanical connector to receive a DNV ‘Statement of Conformity’ to ISO 21329 “Petroleum and Natural Gas Industries – Pipeline Transportation Systems – Test Procedure for Mechanical Connectors.

• Tried & Trusted Technology

* Conductor Supported Platforms Installed in

Numerous Locations

• Flexible Design

* Flexible Well Count & Configuration

* Optimised for Client Needs

* Able to Accommodate a Range of Equipment

• Fast-Track Fabrication & Delivery

* Simplified Installation

* Eliminates Need for Jacket Structure

* Installed from Jack-Up or Light Crane Barge

• Repeatable Solutions

• Optimised Critical Path

• LOW COST

GMC’s Mechanical Connector exceeded both B1 and C1 DNV S-N Connector Fatigue results during testing, as witnessed by DNV.

GMC Mechanical Connector Offshore Makeup

Field Proven Design

Contact Us Today!Let GMC Be Your

Connected Solution!

Photo courtesy of Aquaterra Energy.