CONDENSING HOT WATER BOILER POWER BURNER TC Series, Stainless Steel Flue Gas Passages 399,000 - 5,443,000 BTUH Gas Fired 205 Power Burner Condensing Hot Water Boilers 205 Stainless Steel Boiler A S M E H Temperatures to 190°F Pressures to 80 PSI THE DESIGN Ultra High Efficiency Stain- less Steel Firetube boiler, with Thermal Efficiencies to 98% as witness by a Nation- al Test Lab. The Parker TC Series is one of the most efficient boilers available in the world today. The TC 205 Series is a modern stainless and carbon steel condensing boiler, Packaged with con- ventional boiler controls for simplicity & High efficiency operation for use in closed system heating application. Low NOX Models SCAQMD Certified to 1146.2 ADVANTAGES Stainless and carbon steel boiler built in accordance with ASME code. Triple Flue Gas Pass Fire Tube Type Stainless steel flue passages for resistance to corrosion at low operating temperatures. Extra large amount of heat- ing surface. All units have over 4.1sq.ft. per BHP. None of this heating surface is extended fin. Far more heating surface when compared to the com- petition.. More Heating Surface trans- lates to less metal stress, Heat Flux and longer service life. Sealed combustion chamber for low excess air levels and high efficiencies. Qualifies for Utility Incentive Funding. PARKER BOILER CO. 5930 Bandini Boulevard Los Angeles, CA 90040 Tel (323) 727-9800 Fax (323) 722-2848 www.parkerboiler.com BROCHURE 205 IV-VI 1H1 "Never a Compromise for Quality or Safety" Less heat loss due to Water Backed sealed combustion chamber design. Ease of Cleaning: The Parker front door can eas- ily be swung to gain access to fireside tube surfaces. This allows for easy clean- ing, which is critical for long service life on a condensing boiler. Front door can swing either way. Field proven European Design. Natural or Propane Gas fired. Can burn Biogas and #2 Oil Low & Medium tempera- ture return connections. This increases overall boiler efficiency by allowing cool water to chill flue gasses to the greatest extent. Provided with matched UL Listed Power Gas Burner offering reliable clean com- bustion with low excess air levels and outstanding repeatability. Optional Low NOx Power Gas Burner for NOx levels to 30ppm, 20ppm or 9ppm. Optional • Domestic water heating sys- tems thru heat exchangers or tanks. • Inlet Air ducting to outside. • Outdoor air reset modes. • Lead Lag system. Thermal Efficiencies to 98% New Product

Upload: others

Post on 14-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CONDENSING HOT WATER BOILER N e w POWER BURNER P r … IV-VI.pdfADVANTAGES • Stainless and carbon steel boiler built in accordance with ASME code. • Triple Flue Gas Pass Fire Tube

CONDENSING HOT WATER BOILERPOWER BURNER

TC Series, Stainless Steel Flue Gas Passages399,000 - 5,443,000 BTUH Gas Fired

205 Power Burner Condensing H

ot Water B

oilers

205 Stainless Steel Boiler

ASME

H

Temperatures to 190°FPressures to 80 PSI

THE DESIGNUltra High Efficiency Stain-less Steel Firetube boiler, with Thermal Efficiencies to 98% as witness by a Nation-al Test Lab. The Parker TC Series is one of the most efficient boilers available in the world today. The TC 205 Series is a modern stainless and carbon steel condensing boiler, Packaged with con-ventional boiler controls for simplicity & High efficiency operation for use in closed system heating application.

Low NOX Models SCAQMD

Certified to 1146.2

ADVANTAGES• Stainless and carbon steel

boiler built in accordance with ASME code.

• Triple Flue Gas Pass Fire Tube Type

• Stainless steel fl ue passages for resistance to corrosion at low operating temperatures.

• Extra large amount of heat-ing surface. All units have over 4.1sq.ft. per BHP. None of this heating surface is extended fi n.

• Far more heating surface when compared to the com-petition..

• More Heating Surface trans-lates to less metal stress, Heat Flux and longer service life.

• Sealed combustion chamber for low excess air levels and high effi ciencies.

• Qualifi es for Utility Incentive Funding.

PARKER BOILER CO.5930 Bandini BoulevardLos Angeles, CA 90040Tel (323) 727-9800Fax (323) 722-2848www.parkerboiler.comBROCHURE 205 IV-VI 1H1

"Never a Compromise for Quality or Safety"

Temperatures to 190°FPressures to 80

Low NOX Models Low NOX Models

Certified to 1146.2Certified to 1146.2

• Less heat loss due to Water Backed sealed combustion chamber design.

• Ease of Cleaning: The Parker front door can eas-ily be swung to gain access to fi reside tube surfaces. This allows for easy clean-ing, which is critical for long service life on a condensing boiler.

• Front door can swing either way.

• Field proven European Design.

• Natural or Propane Gas fi red. Can burn Biogas and #2 Oil

• Low & Medium tempera-ture return connections. This increases overall boiler effi ciency by allowing cool water to chill fl ue gasses to the greatest extent.

• Provided with matched UL Listed Power Gas Burner offering reliable clean com-bustion with low excess air levels and outstanding repeatability.

• Optional Low NOx Power Gas Burner for NOx levels to 30ppm, 20ppm or 9ppm.

Optional• Domestic water heating sys-

tems thru heat exchangers or tanks.

• Inlet Air ducting to outside.

• Outdoor air reset modes.

• Lead Lag system.

Thermal Efficiencies to 98%

TC Series, Stainless Steel Flue Gas PassagesN e w

P r o d u c t

Page 2: CONDENSING HOT WATER BOILER N e w POWER BURNER P r … IV-VI.pdfADVANTAGES • Stainless and carbon steel boiler built in accordance with ASME code. • Triple Flue Gas Pass Fire Tube

88

90

92

94

96

98

80 100 120 150

Low Fire

High Fire

Return Water Temperature (°F)Based on 30°F ∆T thru Boiler

Ther

mal

Effi

cien

cy (%

)

PARKER BOILER CO.5930 Bandini BoulevardLos Angeles, CA 90040

Tel (323) 727-9800Fax (323) 722-2848

www.parkerboiler.comBROCHURE 205 IV-VI 1H1

"Never a Compromise for Quality or Safety"

CONDENSING HOT WATER BOILERPOWER BURNERTC Series, Stainless Steel Flue Gas Passages399,000 - 5,443,000 BTUH Gas Fired

Codes / ApprovalsAll Parker Hot Water Boilers are manufactured in accordance with the ASME Heating Boiler Code and registered with the National Board of Boiler and Pressure Ves-sel inspectors. The boiler burner and controls are prewired, factory tested and Listed by a Nationally Recognized Testing Laboratory as Gas Fired Boiler Assemblies to UL Standard 795 & CAN/CGA STD 1-3.1. Product line certifi ed by AHRI and carries IBR rating.

205

Pow

er B

urne

r Con

dens

ing

Hot

Wat

er B

oile

rs

1

9

11

10

2

3 4 5 6

7

8

0

30

60 90

FLUE GAS

4 5 6

Large Stainless Steel Combustion Chamber

Stainless Steel

Return Tube

Stainless Steel Final Pass Firetubes with Turbulators maximizing heat transfer

Front door can swing either way allowing easy access for inspection and cleaning

Burner Mounting Hatch

1. Burner2. Flame Inspection

window3. Hot water outlet4. Safety Relief Opening5. Heating Return

(high temperature)6. Heating Return

(low temperature)7. Combustion Chamber8. Flue Connection9. Turbulators10. Flue Pipes11. Second Flue Pass

205 Stainless Steel Boiler

Boiler InternalsTriple Pass

Matched Integral Riello Burners• Mounted, packaged

• Factory fi re tested

• Low O2’s

• Outstanding repeatability

• Reliable Operation