condensing hot water boiler n e w power burner p r … iv-vi.pdfadvantages • stainless and carbon...
TRANSCRIPT
CONDENSING HOT WATER BOILERPOWER BURNER
TC Series, Stainless Steel Flue Gas Passages399,000 - 5,443,000 BTUH Gas Fired
205 Power Burner Condensing H
ot Water B
oilers
205 Stainless Steel Boiler
ASME
H
Temperatures to 190°FPressures to 80 PSI
THE DESIGNUltra High Efficiency Stain-less Steel Firetube boiler, with Thermal Efficiencies to 98% as witness by a Nation-al Test Lab. The Parker TC Series is one of the most efficient boilers available in the world today. The TC 205 Series is a modern stainless and carbon steel condensing boiler, Packaged with con-ventional boiler controls for simplicity & High efficiency operation for use in closed system heating application.
Low NOX Models SCAQMD
Certified to 1146.2
ADVANTAGES• Stainless and carbon steel
boiler built in accordance with ASME code.
• Triple Flue Gas Pass Fire Tube Type
• Stainless steel fl ue passages for resistance to corrosion at low operating temperatures.
• Extra large amount of heat-ing surface. All units have over 4.1sq.ft. per BHP. None of this heating surface is extended fi n.
• Far more heating surface when compared to the com-petition..
• More Heating Surface trans-lates to less metal stress, Heat Flux and longer service life.
• Sealed combustion chamber for low excess air levels and high effi ciencies.
• Qualifi es for Utility Incentive Funding.
PARKER BOILER CO.5930 Bandini BoulevardLos Angeles, CA 90040Tel (323) 727-9800Fax (323) 722-2848www.parkerboiler.comBROCHURE 205 IV-VI 1H1
"Never a Compromise for Quality or Safety"
Temperatures to 190°FPressures to 80
Low NOX Models Low NOX Models
Certified to 1146.2Certified to 1146.2
• Less heat loss due to Water Backed sealed combustion chamber design.
• Ease of Cleaning: The Parker front door can eas-ily be swung to gain access to fi reside tube surfaces. This allows for easy clean-ing, which is critical for long service life on a condensing boiler.
• Front door can swing either way.
• Field proven European Design.
• Natural or Propane Gas fi red. Can burn Biogas and #2 Oil
• Low & Medium tempera-ture return connections. This increases overall boiler effi ciency by allowing cool water to chill fl ue gasses to the greatest extent.
• Provided with matched UL Listed Power Gas Burner offering reliable clean com-bustion with low excess air levels and outstanding repeatability.
• Optional Low NOx Power Gas Burner for NOx levels to 30ppm, 20ppm or 9ppm.
Optional• Domestic water heating sys-
tems thru heat exchangers or tanks.
• Inlet Air ducting to outside.
• Outdoor air reset modes.
• Lead Lag system.
Thermal Efficiencies to 98%
TC Series, Stainless Steel Flue Gas PassagesN e w
P r o d u c t
88
90
92
94
96
98
80 100 120 150
Low Fire
High Fire
Return Water Temperature (°F)Based on 30°F ∆T thru Boiler
Ther
mal
Effi
cien
cy (%
)
PARKER BOILER CO.5930 Bandini BoulevardLos Angeles, CA 90040
Tel (323) 727-9800Fax (323) 722-2848
www.parkerboiler.comBROCHURE 205 IV-VI 1H1
"Never a Compromise for Quality or Safety"
CONDENSING HOT WATER BOILERPOWER BURNERTC Series, Stainless Steel Flue Gas Passages399,000 - 5,443,000 BTUH Gas Fired
Codes / ApprovalsAll Parker Hot Water Boilers are manufactured in accordance with the ASME Heating Boiler Code and registered with the National Board of Boiler and Pressure Ves-sel inspectors. The boiler burner and controls are prewired, factory tested and Listed by a Nationally Recognized Testing Laboratory as Gas Fired Boiler Assemblies to UL Standard 795 & CAN/CGA STD 1-3.1. Product line certifi ed by AHRI and carries IBR rating.
205
Pow
er B
urne
r Con
dens
ing
Hot
Wat
er B
oile
rs
1
9
11
10
2
3 4 5 6
7
8
0
30
60 90
FLUE GAS
4 5 6
Large Stainless Steel Combustion Chamber
Stainless Steel
Return Tube
Stainless Steel Final Pass Firetubes with Turbulators maximizing heat transfer
Front door can swing either way allowing easy access for inspection and cleaning
Burner Mounting Hatch
1. Burner2. Flame Inspection
window3. Hot water outlet4. Safety Relief Opening5. Heating Return
(high temperature)6. Heating Return
(low temperature)7. Combustion Chamber8. Flue Connection9. Turbulators10. Flue Pipes11. Second Flue Pass
205 Stainless Steel Boiler
Boiler InternalsTriple Pass
Matched Integral Riello Burners• Mounted, packaged
• Factory fi re tested
• Low O2’s
• Outstanding repeatability
• Reliable Operation