condensate pump selection guide
TRANSCRIPT
CONDENSATE PUMP SELECTION GUIDE
Si-30 120 V
Si-30 230 V©2014 MITSUBISHI ELECTRIC US, INC.
• Flow rate up to 3.7 gph• Dry suction lift up to 16.5 ft• Max head of 23 ft• Self priming• Energy Efficient
• Flow rate up to 13.2 gph• Max head of 66.5 ft• Thermally protected• Self Priming
* Not available with reservoir sensor to provide automatic shutoff
MultiTank• Ultra reliable - incorporates
electronic level sensing with no moving parts
• Whisper quiet - reliably removes condensate
• Multi port - up to 6 condensate lines• Impact resistant - exceptionally
high durability• Fit fast - floor or wall mounted
Plenum-Rated
Plenum-Rated
Model Voltage [V]
X87-711 110
X87-721 208-230
Model Voltage [V]
X87-831 110
X87-835 208-230
Model Voltage [V]
C13-103 N/A
CONDENSATE PUMP SELECTION GUIDE
MiniBlue
MaxiBlue
Accessories
Tel: +1 770 831 1122 Ext 504
www.charlesaustenusa.com
www.bluediamondpump.com
USA Part Numbers Mini Blue X87-512 - Mini Blue 230V Temp Sensor X87-505 - Mini Blue 110V Temp Sensor Maxi Blue X87-721 - Maxi Blue 230V Reservoir X87-723 - Maxi Blue 230V Temp Sensor X87-722 - Maxi Blue 230V DrainStik X87-711 - Maxi Blue 110V Reservoir X87-713 - Maxi Blue 110V Temp Sensor X87-712 - Maxi Blue 110V DrainStik Accessories & Spares C01-226 - Black Stepped Adaptor C01-231 - Blue Stepped Adaptor C13-103 - Mini Blue / Maxi Blue / Blue Diamond 5m Extension Cable S12-002 - Mini Blue / Maxi Blue / Blue Diamond Temp Sensors C21-008 - Maxi Blue Reservoir Sensor S12-004 - Maxi Blue DrainStik S09-042 - Inlet Silencer S09-036 - Silencer Assembly Kit
Blue Diamond Pumps feature:• Exceptional performance from a small package• Exceptionally quiet with no vibration• Can tolerate both small debris and running dry• Can be mounted in any position• UL certified plenum rated• Includes flexible and rigid cone adapter
Additional Accessories Installation Possibilities
What's in the Box
F10-010Mounting Feet
C13-103 MegaBlue/MaxiBlueExtension Cable 5m
1
2
3
16.5ft
C13-192Extension
Blue Diamond pumps are slim enough to fit into line hide or ducting, powerful enough for distant location and quiet enough for ceiling mounting. It’s your choice. Commissioning is so easy, linkpump to sensing option with single wire DIN plug and connect in/out tubing provided - plug and play, fit and forget!
1 Inside Line Hide 2 Above Ceiling 3 Remote
Snapper ClipRigid Stepped
AdaptorFlexible Stepped
AdaptorSensing Option
CONDENSATE PUMP SELECTION GUIDE CONDENSATE PUMP SELECTION GUIDE
Performance Charts
CONDENSATE PUMP SELECTION GUIDE
0
1
3
5
7
9
11
13
Foot Head
US
Gal
lons
/Hou
r
Plot of Flow Rate Against Head
US
Gal
lons
/ H
our
Foot Head
1
2
3
5 10 15 20 25 30 35
Plot of Flow Rate Against Head
4
7040100 805020 906030
Additional Accessories
Actual Flow Rates (GPH)
Si-30 120/230V• Flow rate up to 5.0 gph• Suction head up to 10 ft• Discharge head up to 33 ft• Small size / High performance
4 8 1412 16 18 20
2
4
6
12
8
10
2 6 10
DIS
CHA
RGE
HEA
D
FLOW RATE
14
3 41 2 5 5.2 (US gph)
3230
40
20
10
(Ft)
(l/h)
(m)
CONDENSATE PUMP SELECTION GUIDE
Suction head
0 ft (0m)
3.3 ft (1m)
6.6 ft (2m)
10 ft (3m)
Discharge head
0 ft (0m)
6 ft (2m)
13 ft (4m)
20 ft (6m)
26 ft (8m)
33 ft (10m)
0 ft (0m)
6 ft (2m)
13 ft (4m)
20 ft (6m)
0 ft (0m)
6 ft (2m)
13 ft (4m)
0 ft (0m)
6 ft (2m)
13 ft (4m)
15 ft (4.5m)
5.0
4.2
3
3.7
2.9
0.5
2.9
2.4
2.6
2.1
30 ft (9m)
4.7
3.9
2.9
2.5
1.6
1.1
3.4
2.6
1.8
1.2
2.6
2.1
1.5
2.4
1.8
1.3
60 ft (18m)
4.5
3.7
2.8
2
1.3
0.9
3.2
2.4
1.6
1.1
2.4
1.8
1.3
2.1
1.6
1.1
100 ft (30m)
4.2
3.5
2.6
1.7
1.1
0.7
2.9
2.1
1.3
2.1
1.6
1.2
1.8
1.3
Total tube length using 1/4” (6mm) hoseA B C
Detection Unit PVC TubingCheck valve Self-sealing accessory
MultiTank
Si30
2.65
"
2.28"
0.2"
6.2"
15.7"
1.75"2.625"
78.74"
9.83"
4.72"
0.31
"
2.28"
2.66
3"
2.18
"
.55"
Mains Lead Length
13.9"
7"
5"
4.1"
6.7"
4.3"
2.37
5"
2.37
5"
1.75
"
Manufacturer Blue Diamond Sauermann
Model MaxiBlue MegaBlue Si30
Flow [g/hr] 3.7 13.2 5
Head [ft] 23 66.5 33
Suction Lift [ft head] 16.5 23 10
Sound Pressure [dBA] 25.5 39.5 20
Sensor—Liquid in Drainpan Thermistor Thermistor Float Switch
Pass Solids up to 1 mm Yes Yes Yes
Thermal Protection (Overheat) 257° F 257° F 194° F
Intermittent Operation Cycle No Limit No Limit 3s On—7s OFF
Run Dry for Extended Period Yes Yes "No
Mounting Position Any Orientation Any OrientationMounted vertically or
horizontally
Self-Priming Yes Yes Yes
Drain Sreen/Filter requiring cleaning
No No No
Voltage Options [V] 110/230 110/230 120/230
Weight [kg] 0.7 1.0 0.4
Temp. Sensing X X
Reservoir Sensing* X X X
DrainStik X X
Cooling Signal X
Unit Disconnect Sensor X X No
UL Certified Yes Yes Yes
Plenum Rated Yes Yes No
Manufacturer Warranty 3 Years 3 Years 2 Year
Tier 1 2 1
Specifications
* Standard Option
Please Recycle
/mehvac /mitsubishihvac /mitsubishihvac
Mitsubishi Electric Cooling & Heating1340 Satellite Boulevard, Suwanee, GA 30024Phone: 800-433-4822 Fax: 800-658-1458
Model Tier
PKFY-P06-30NBMU-E2 1
PKFY-P06-30NHMU-E2 1
PKFY-P06-30NKMU-E2 1
PCFY-P15-36NKMU-ER1 1
PCFY-P24-36NKMU-ER1 1
PFFY-P06-24NEMU-E 1
PFFY-P06-24NRMU-E 1
PVFY-P12-54E00B 1
PEFY-P15-48NMHU-E2 1
PEFY-P54NMHU-E 2
PEFY-P06-54NMAU-E3 1
PEFY-P06-24NMSU-E2 1
PEFY-P72-96NMSHU-E 2
Model Tier
MS-A09-12WA-1 1
MSY-GE09-18NA-8 1
MSY-GE24NA 1
MSY-D30-36NA-8 1
MSZ-FE09-12NA-8 1
MSZ-FE18NA 1
MSZ-GE06NA-8 1
MSZ-GE09-18NA-8 1
MSZ-GE24NA 1
MSZ-D30-36NA-8 1
MFZ-KA09-18NA 1
PKA-A12-18HA4 1
PKA-A24KA4 1
PKA-A30-36KA4 1
PCA-A24KA4 1
PCA-A30-42KA4 1
CITY
MUL
TI
P-SE
RIES
M-S
ERIE
S
MOISTURE REMOVAL CHARTS