concise laboratory catalogue - · pdf fileconcise “laboratory” catalogue portable...
TRANSCRIPT
Concise “laboratory” catalogue
Portable and bench-top instruments for pH, EC, ISE, DO and ˚C measurements.Simple and advanced models covering from routine measurements to maximum requirements in investigation.
High quality sensors range with unique performance.pH electrodes with patented ContATC temperature sensor. ISE electrodes without internal electrolyte.
Burettes and titrators for volumetric analyses.Liquid microdispensing at reasonable price. The most rapid and “productive” automatic titrators.
2008
Quality at a reasonable price
Instruments, sensors and accessories for:• research and education,• chemical and pharmaceutical industry,• agriculture, food industry, etc…
Portable instruments ............................................. 4pH-meter PH 25
Multimeter MM 40Conductivity meter CM 35Oxymeter OXI 45Thermometer TM 65
Sensors for portable instruments .......................... 5
pH-meters SERIES ................................................. 6pH-Meter Basic 20pH-Meter GLP 21
pH & Ion-Meter GLP 22
pH-meter + burette ................................................ 7PH-Burette 24 1S
PH-Burette 24 2S
pH, redox, ISE electrodes ....................................... 8
Conductivity meters SERIE ................................. 10EC-Meter Basic 30EC-Meter GLP 31
Conductivity cells .................................................. 11
Multimeter ............................................................ 12MultiMeter MM 41
Solutions ............................................................... 13
Automatic burettes .............................................. 14Burette 1S
Multi-Burette 2SMulti-Burette 4S
Karl Fischer titrators ............................................. 15TitroMatic KF 1STitroMatic KF 1S 2BTitroMatic KF 2S 2B
Contents
Concise “laboratory” catalogue 3
Model PH 25 MM 40 CM 35 OXI 45 TM 65
Measured parameter
Measuring range pH -2 … 16±1500 mV
-20 … 150 ˚C -200 … 600 ˚C
pH -2 … 160.01 µS/cm … 200 mS/cm TDS, 0.01 … 199.9 mg/l
-9.9 … 99.9 ˚C
0.01 µS/cm … 500 mS/cmNaCl, 0.0 … 1999 mg/l
-20 … 150 ˚C-200 … 600 ˚C
0.1 … 600 %0.01 … 60.0 mg/l
0.0 … 50.0 ˚C
-200 … 850 ˚C-328 … 1562 ˚F
Temperature compensation Manual or automatic Automatic Automatic Automatic --
Calibration With 1, 2 or 3 buffers pH, with 1, 2 or 3 buffersEC, with 1, 2 or 3 standards
With 1, 2 or 3 standards Automatic, in calibration vessel
Error compensation of the probe in 2 points
Light, functional and very robustDesigned to work in harsh conditions, in industry and in field or lab.Advantages of CRISON portable instruments:
• Truly portable.• Easy to use.• Ergonomic design.• Shock resistant.• Long-life batteries.• Industrial key-pad. • Very competitive pricing.• Manufacturer’s after-sales service.
Portable instruments, general view
Double LCD display, for simultaneous readings of the measured parameter and temperature.
ABS casing with IP 65 waterproof.
“Long life” membrane key-pad,for industrial use.
Optional carry case containing all necessary elements to work correctly.
MP-5 connector. High quality sensor’s connector with IP 67 waterproof.
Thermometer TM 65
Concise “laboratory” catalogue4
50 50
50 60/50 61 50 62
50 59 51 20
50 63 50 64
50 52 50 53
50 55
50 50 TT= temperature sensor 50 52 T 50 53 T
50 90
50 91
50 92
50 94
50 95
50 96
50 97
50 98
50 99
Sensors for portable instruments
pH electrodesComplete range with the best electrodes on the market. Different electrolytes, diaphragms, refer-ence elements, measuring ranges, etc. In addition, electrodes with built-in tempera-ture sensor (Pt 1000).50 50, for general use.50 50 T, for general use, with Pt 1000.50 52, for difficult samples. 50 52 T, for difficult samples, with Pt 1000.50 53, puncture electrode (stainless steel).50 50 T, puncture electrode (stainless steel), with Pt 1000.
RedoxAn electrode similar to the pH sensors, where the glass membrane is replaced by platinum wire. 50 55, platinum
Storage protector.
It screws directly on the electrode’s handle. It avoids the possible sensor breakage due to flexion. This protector does not generate over-pressure on the diaphragm preventing its fast clogging.
Conductivity cellsAll of them with sensor Pt 1000. 50 60, 0.2...200.000 µS/cm, universal, plastic and platinum.50 61, 0.2...200.000 µS/cm, universal, glass and platinum.50 62, 5...50.000 µS/cm, “dirty” samples, titanium.50 63, 100...500.000 µS/cm, high conductivities, glass and platinum.50 64, 5...50.000 µS/cm, Low Cost, ABS and titanium.
D.O. Sensor.51 20, with extraordinary membrane, compounded by thin stainless steel mesh covered by silicone. Maximum quality electrode at very competitive price.
TemperatureprobesVersions Pt 100, Pt 1000 and Thermocouple type K. Different lengths and shapes.
Multisensor50 59, inside there are one pH elec-trode, one conductivity cell and one temperature sensor.Short response time for the 3 parameters.It is developed to work exclusively with multimeter MM 40.pH, 0 ... 14EC, 5 ... 30.000 µS/cm0 ... 80 ˚C
Concise “laboratory” catalogue 5
Model pH-Meter BASIC 20 pH-Meter GLP 21 pH & Ion-Meter GLP 22
Parameters to measure
Measuring range pH -2 … 16± 2000 mV
-20 … 150 ˚C
pH -2 … 16± 2000 mV
-20 … 150 ˚C
pH -2 … 16± 2000 mV
ISE, 10-6 M … 10-1 M (ppm o g/l)-20 … 150 ˚C
Resolution pH 0.011 mV0.1 ˚C
Selectable, 0.1 / 0.01 / 0.001 pHSelectable, 1 / 0.1 mV
0.1 ˚C
Selectable, 0.1 / 0.01 / 0.001 pHSelectable, 1 / 0.1 mV
ISE, Selectable0.1 ˚C
Measuring channels 1 1 2
Magnetic stirrer 1 1 1 + 1 optional
Data Logger — Up to 400 measurements Up to 400 measurements per channel
Data output — Printer or PC Printer or PC
Laboratory pH-Meters, Series
Support for 1, 2 or 3 sensors. With place for cable fi xing avoid-ing its breakage.
Holes for a sensor’s protector or a spare electrode.
Large graphic display.It speaks by its own.
Thermal or dot matrix printers, connectable to the GLP21+ and GLP22+.
The magnetic stirrer integrated in all models is controlled from the instrument.
Industrial quality, easy to use key-pad.
Calibration fl asks with magnetic bar. With 40 ml of buffers more than 10 calibrations can be performed.
Three models, one philosophyDeveloped as a station for integral work.Some common features:
• Automatic control over the activation/deactivation of a stirrer, allowing stirring speed regulation.
• Several measuring modes: by stability, in continuous and others. • pH calibration in 1, 2 or 3 points and mV calibration with one redox standard. • Possibility to compensate the error of the temperature sensor (GLP 21+ and 22+)• Programmable calibration validity.• Messages in 5 languages.
Concise “laboratory” catalogue6
Model pH-Burette 24 1S pH-Burette 24 2S
Parameters to measure
Measuring range (as a pH-meter) pH -2 … 16± 2000 mV
-20 … 150 ˚C
As a burette Motor step by step, resolution 1/40000
1 syringe 2 syringes
As a titrator End point titrations in manual or sequential mode
As a pH regulator In 1direction (acid or alkali) In 2directions (acid and alkali)
Measuring channels 1 2
Connections for 1 electrode1 stirrer
2 electrodes2 stirrers
Data output Printer or PC
PH-Burette 24
• Solutions preparation.
• Enzyme preparation.
• Total acidity in food.
• Chlorides in general.
• SO2 (sulphurous) in wine.
• Measure and regulation of pH, PH-Stat.
• etc, etc …
A combination between a pH-meter and a BuretteUnique instrument on the market.Two versions: with one or two working places.A semi-automatic titrator priced as a digital burette.Reagent saving due to the high-resolution burette.They are supplied with specifi c program for burette auto-calibration.
Applications
Concise “laboratory” catalogue 7
T = temperaturesensor
T = temperaturesensor
T = temperaturesensor
T = temp.sensor
T = temp.sensor
Code 50 10 50 10 T 50 11 50 11 T 50 14 50 14 TpH and temperature range pH 0 … 14, 0 … 80 ˚C pH 2 … 14, 0 … 80 ˚C pH 0 … 14, -10 … 100 ˚C
Reference element Ag/ AgCl wire Sleeved Ag/ AgCl wire Encapsulated Ag/AgCl + Ag+ barrier
Diaphragm Ceramic Annular open 2 ceramic
Electrolyte Gel (non refi llable) Solid (non refi llable) CRISOLYT
Code 50 15 50 15 T 50 21 50 21 TpH and temperature range pH 0 … 14, -5 … 100 ˚C pH 0 … 14, 0 … 60 ˚C
Reference electrolyte Encapsulated Ag/AgCl + Ag+ barrier Encapsulated Ag/AgCl + Ag+ barrier
Diaphragm 3 ceramic Sleeve
Electrolyte CRISOLYT G CRISOLYT
pH electrodes
The basic onesElectrodes with fixed cable and BNC connector covering 90% of the applications. All models have the version with built-in temperature sensor Pt 1000.50 10, Low Cost, plastic body.50 10 T, Low Cost, with Pt 1000.50 11, for foodstuff.50 11 T, for foodstuff, with Pt 100050 14, for aqueous media in general.50 14 T, for aqueous media in general, with Pt 1000.
The high-tech onesHigh quality electrodes with fi xed cable and BNC connector.All of them with encapsulated reference system and silver ion barrier. All models have the version with built-in temperature sensor Pt 1000.50 15, for foodstuff, chemistry and pharmacy.50 15 T, for foodstuff, chemistry and pharmacy, with Pt 1000.50 21, for diffi cult samples.50 21 T, for diffi cult samples, with Pt 1000.
Concise “laboratory” catalogue8
Platinum
50 44I.S.E.
Code 50 26 50 27 50 28 50 29 50 56 50 57Measuring range pH 1 … 11
0 … 80 ˚CpH 0 … 140 … 80 ˚C
pH 0 … 140 … 80 ˚C
pH 0 … 140 … 80 ˚C
± 2000 mV0 … 80 ˚C
± 2000 mV0 … 80 ˚C
Reference element Encapsulated Ag/AgCl Encapsulated Ag/AgCl
Diaphragm 1 ceramic PTFE ring 1 ceramic 1 ceramic 1 ceramic 1 ceramic
Electrolyte CRISOLYT CRISOLYT CRISOLYT CRISOLYT Gel (non refi llable) CRISOLYT
Code Ion96 50 Sodium (Na+),
96 51 Bromide (Br-)
96 52 Chloride (Cl-)
96 53 Cyanide (CN-) and iodide (I-)
96 54 Silver / sulphide (Ag+/S2-)
96 55 Fluoride (F-)
96 57 Copper (Cu2+)
96 58 Cadmium (Cd2+)
96 60 Calcium (Ca2+)
96 61 Potassium (K+)
96 62 Nitrate (NO3-)
96 63 Amonium (NH4+)
96 64 Nitrite (NO2-)
pH, metallic, I.S.E. and reference electrodes
Special pH electrodesElectrodes with fixed cable and BNC connector.50 26, for samples with HF(up to 1g/l at pH ≥ 3)50 27, for measurements on surfaces.50 28, micro samples, Ø 3.50 29, micro samples, Ø 6.
Metallic electrodesElectrodes with fixed cable and BNC connector.50 56, platinum, low maintenance.50 57, platinum, liquid electrolyte.
I.S.E. ElectrodesCompact electrodes, maintenance not required.Without internal electrolyte nor spare membranes. High sensitive and long last-ing membranes.With fi xed cable and BNC connector.There are S7 connector versions, please, ask for more details.
Reference electrode50 44, reference electrode with lithium acetate 0.1 M, for ISE applications. Suitable for all CRISON selective electrodes. With fi xed cable and banana connector.
Electrodes from the series 52 XX with S7 screw capThis is the classic range of CRISON electrodes. Please, ask for more details.
Concise “laboratory” catalogue 9
Model EC-Meter BASIC 30 EC-Meter GLP 31
Measured parameters
Measuring range 0.01 µS/cm … 500 mS/cmNaCl (Salt), 5.85 mg/l … 311.1 g/l
-20 … 150 ˚C
0.001 µS/cm … 1000 mS/cmNaCl (Salt), 5.85 mg/l … 311.1 g/l
TDS, 0 mg/l … 500 g/l-20 … 150 ˚C
Temperature coeffi cient Linear, TC 0.00 … 5.00 %/ ˚C Linear, TC 0.00 … 5.00 %/ ˚CNon linear for natural waters, UNE-EN 27888
Reference temperature 20 or 25 ˚C 20 or 25 ˚C or any value between 0 and 99 ˚C
Calibration Automatic recognition of CRISON standards. Manual introduction of the cell constant.
Data Logger — Up to 400 measurements
Data output — Printer or PC
Laboratory conductivity meters, Series
Cell support.With place for cable fi xing avoiding its breakage.
Large graphic display.It speaks by its own.
Thermal or dot matrix printers, connectable to the GLP 31+.
Industrial quality, easy to use key-pad.
Calibration fl asks with magnetic bar. With 50 ml of standard up to 3 calibrations without error.
Two models, one philosophyDeveloped as a station for integral work.Some common features:
• Automatic control over the activation/deactivation of a stirrer, allowing stirring speed regulation.
• Several measuring modes: by stability, in continuous and others.• EC calibration with 1, 2 or 3 standards.• Possibility to compensate the error of the temperature sensor (GLP 31+)• Programmable calibration validity.• Messages in 5 languages.
The magnetic stirrer integrated in all models is controlled from the instrument.
Concise “laboratory” catalogue10
50 70 50 71 50 72
Exclusive for
Basic 30 , GLP 31
and MM 41.
Temperaturesensor
Temperaturesensor
TemperaturesensorTemperature
sensor
Temperaturesensor
Code 50 70 50 71 50 72 50 73Measuring range (µS/cm) 0.2 … 200.000 0.05 … 30.000 100 … 500.000 100 … 50.000
Temperature range (˚C) -30 … 85 -30 … 85 -30 … 85 0 … 85
Approximate constant (cm-1) 0.7 0.1 10 0.3
Materials Glass / platinum Glass / platinum Glass / platinum Titanium
Code 52 93 52 92 52 95 52 98 52 87Measuring range (µS/cm) 0.2 … 100.000 0.2 … 100.000 0.1 … 10.000 100 … 500.000 1 … 80.000
Temperature range (˚C) -30 … 85 -30 … 85 -30 … 85 -30 … 85 -30 … 85
Approximate constant (cm-1) 0.7 1 0.1 10 1
Materials Glass / platinum Glass / platinum Glass / platinum Glass / platinum Glass / platinum
Conductivity cells
For Basic 30+, GLP 31+ and MM41With telephone connector with 8 contacts.Different models to cover the variety of samples and measur-ing ranges.All include temperature sensor Pt 1000.50 70, universal.50 71, for low conductivities.50 72, for high conductivities.50 73, for dirty or viscous samples.
For conductivity meterswith banana connectionCells with banana connection, connectable to the majority of conductivity meters on the market.52 93, universal, with built-in Pt 1000 temperature sensor.52 92, for general use.52 95, for low conductivities.52 98, for high conductivities.52 87, for measurements in continuous fl ow.
It is recommended to use the models 52 92, 52 95 and 52 98 together with A.T.C. 55 31.
Concise “laboratory” catalogue 11
NE W
Model MultiMeter MM 41Two channels One double One simple
Parameters to measure
Measuring range pH -2 … 16± 2000 mV
0.001 µS/cm … 1000 mS/cmNaCl (Sal), 5.85 mg/l … 311.1 g/l
TDS, 0 mg/l … 500 g/l-20 … 150 ˚C
pH -2 … 16± 2000 mV
ISE, 10-5 M … 10-1 M-20 … 150 ˚C
Data Logger Up to 400 measurements per channel
Magnetic stirrer 1 + 1 optional
Data output Printer or PC
Multiparametric instrument MultiMeter MM41
Support for 1, 2 or 3 sensors. With place for cable fi xing avoiding its breakage.
Connectable sensors: The same as for the pH-meters and conductivity meters Series+ (pages 8, 9 and 11)
Holes for a sensor’s protector or a spare electrode.Large graphic display.
It speaks by its own.
The magnetic stirrer integrated in all models is controlled from the instrument.
Industrial quality, easy to use key-pad.
Calibration fl asks with magnetic bar. With 50 ml of standard, several calibrationscan be performed.
Two instruments in oneAn instrument joining GLP22+ and GLP31+.With two measuring channels
• Channel 1: for simultaneous pH, EC and temperature measurement.• Channel 2: for pH or redox or ISE measurement.• Connected to a sample changer and a PC, using the software
ComLabo, the simultaneous measurement of pH and conductivity in large number of samples is possible.
• Optionally, connection of a second magnetic stirrer.
Concise “laboratory” catalogue12
pH buffers EC standards Redox standard Electrolytic s. Regeneration s. ISE measurementsValues 7.00 (at 25 ˚C)
4.01 (at 25 ˚C)9.21 (at 25 ˚C)
147 µS/cm (at 25 ˚C)1413 µS/cm (at 25 ˚C)12.88 mS/cm (at 25 ˚C)80.4 mS/cm (at 25 ˚C)111.8 mS/cm (at 25 ˚C)
220 mV (a 25 ˚C) CRISOLYTCRISOLYT ACRISOLYT GCRISOLYT V
LiCl 1M in ethanolKNO3 1M
Electrode-cleanerDiaphragm-cleaner
Membrane-reactivator
TISAB IIIAl2(SO4)3
Lithium acetate
Certifi cate Yes Yes No No No No
Presentation 125 / 250 / 1000 ml 125 / 250 / 1000 ml 250 / 1000 ml 250 ml 250 ml 125 / 250 ml
Solutions
• pH buffers.• Conductivity standards, EC.• Electrolytic solutions.• Electrode’s regeneration solutions.• Solutions for ISE measurements.
For instrument calibration and sensor maintenanceThe pH buffers and conductivity standards are:
• with NIST traceability.• supplied with Certifi cate of analysis.
Concise “laboratory” catalogue 13
Model Burette 1S DPD Burette 1S Multi-Burette 2S Multi-Burette 4SNumber of syringes 1 1 2 4
Magnetic stirrer (optional) 1 1 2 4
Dilution programs Yes — — —
Dispensing programs Yes
Preparation programs — Yes
Peristaltic pumps — optional, 1 or 2
Burettes
A range of high quality and precision burettes at reasonable priceThey cover the applications between the manual digital dispensers and the expensive motorized burettes.The piston’s stroke is divided in 40000 steps.The resolution on display is 1 ul.The main applications are:
• Solution preparation.• Repetitive reagent dispensing.• Standard dilution.• Titrations with optical indicator.• etc.
Concise “laboratory” catalogue14
Model TitroMatic KF 1S TitroMatic KF 1S 2B TitroMatic KF 2S 2BNumber of syringes 1 1 2
Pumps for fi lling/emptying vessel — 2 2
Standardisation programs Yes
Several titration programs Yes
Burette self-calibration program Yes
Data output Printer or PC
Automatic Karl Fischer titrators
Water determination according to Karl FischerThree versions covering the different customer requirements.Advantages:
• Very easy to use.• Automatic and periodic air bubbles elimination from the reagent circuit, tubes and syringe.• Intelligent control over the vessel drift and different possibilities for its compensation.• Adaptable to the different KF reagents on the market. • High reliability of the results.• Very reasonable price.• etc.
Concise “laboratory” catalogue 15
Instruments developed and manufactured in Spain by CRISON INSTRUMENTS, S.A.
www.crisoninstruments.com
Authorised CRISON dealer:
Códi
go 0
63-E
, Edi
ción
Febr
ero
2008
High quality sensors