Refractive Outcome of Combined Phacoemulsification and Endoscopic Cyclophotocoagulation
Authors
Kang S1, Luk S1, Han H1, Cordeiro MF1,2,3, Ahmed F1,2, Bloom P1,2, Crawley L1,2
Institution
1 Imperial College Healthcare NHS Trust
2 Imperial College London
3 Glaucoma & Retinal Neuro-degeneration Research Group, UCL Institute of Ophthalmology, London
Corresponding author
Miss Swan Kang
Email: [email protected]
Address: The Western Eye Hospital, 153-173 Marylebone Road, London NW1 5QH
Mobile: 07958585904
Phone: 02033126666
Fax: 02078866200
Keywords: phacoemulsification, endoscopic cyclophotocoagulation, phaco-ECP, refractive outcome, glaucoma,
cataract
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Financial Support: nil
The authors have no financial or proprietary interests in any material or method mentioned.
There is no involvement of research funding.
Conflict of interests
The authors declare no conflict of interests.
The findings has only been presented at the local hospital meeting – West London Research Medal
2
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Abstract
Purpose
To compare the refractive outcome of eyes that underwent phacoemulsification combined with endoscopic
cyclophotocoagulation (phaco-ECP) with the eyes that underwent phacoemulsification alone.
Methods
A retrospective case series review of 103 consecutive eyes that underwent phaco-ECP and 62 eyes that
underwent phacoemulsification between January 2006 and August 2012 was conducted. Post-operative
refractive outcomes were obtained by subjective refraction or autorefraction. Demographic data, best corrected
visual acuity (BCVA), intraocular pressure (IOP), number of glaucoma agents and mean deviation of the
Humphrey visual field test (MD) were also analysed.
Results
The total number of eyes included in the study was 62 eyes for the phaco-ECP group and 62 eyes for the control
group who underwent phacoemulsification alone. More than 90% of eyes (n=56) in phaco-ECP group achieved
post-operative refraction within +/- 1 dioptre (D) of the target refraction. In the control group 100% of eyes
achieved post-operative refraction within +/- 1D of the target refraction. When comparing the difference
between the target and the actual refractive outcome between the phaco-ECP and the control group, there was
no statistically significant difference.
3
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
Conclusions
Refractive outcome after phaco-ECP is comparable to phacoemulsification alone. This study suggests that the
intraocular lens power can be selected as for cataract surgery alone and that ECP does not change the effective
lens position significantly, therefore no modification of biometry formulae is required. Phaco-ECP should be
considered as an effective, safe and predictable surgical treatment option for glaucoma patients with co-existing
cataract.
4
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
Introduction
Patients with glaucoma frequently develop cataract due to a number of plausible reasons such as the use of
topical medications and previous laser or surgical procedures as well as physiological aging.1 Cataract itself may
create challenges in glaucoma management by reducing vision, obstructing aqueous outflow and by making
perimetry and optic disc assessment more difficult. Therefore, the timely management of both conditions is co-
dependent in improving outcome.
Endoscopic cyclophotocoagulation (ECP) using a diode laser guided by an endoscope provides targeted ablation
of the ciliary body under direct visualisation, while minimising surrounding tissue damage. ECP is gaining its
popularity in the UK with currently 14 centres using the technology. The technique of combining
phacoemulsification with endoscopic cyclophotocoagulation (phaco-ECP) has emerged as a viable option to
simultaneously treat both cataract and glaucoma.2 The inherent advantages of the combined procedure include a
single recovery period and effective reduction in IOP.3
Cataract surgery can correct refractive error by accurate selection of appropriate intraocular lens (IOL) power.4
As ECP causes contraction of the ciliary processes and the zonules insert on these processes, it may be
hypothesised that this would change the effective position of the IOL which might in turn alter the post-
operative refractive outcome adversely. The aim of this study was to investigate the refractive outcome of the
combined phaco-ECP.
5
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
Materials and Methods
Patients
The case records of 103 consecutive eyes that underwent phaco-ECP and 62 eyes of age-matched glaucoma
patients who underwent phacoemulsification alone at a single tertiary referral center (The Western Eye Hospital,
London, UK) between January 2006 and August 2012 were reviewed retrospectively. Patients with open angle
glaucoma were included in the study, including normal tension, pseudoexfoliation, and pigmentary glaucoma
subtypes. Patients with complete demographic, operative and follow-up data were subsequently entered into the
study. Excluded from the study were patients referred from other centres for phaco-ECP procedures and
subsequently had follow-up appointments at their local clinics and those who had visual acuities of counting
fingers or worse or who were lost to follow-up. Pre- and post-operative Snellen visual acuities (VA) were
recorded. Refraction was obtained by autorefraction performed at clinic visits (Canon Auto ref-keratometer
RK5) or subjective refraction reported by optometrists. All complications were noted. Intraocular pressure (IOP)
measured by calibrated Goldmann applanation tonometry, mean deviation (MD) of automated Humphrey visual
field (SITA standard 24-2) and numbers of topical or systemic anti-glaucoma agents were also recorded.
Standard of Care
The Royal College of Ophthalmologists’ cataract surgery guidelines 2010 set a benchmark for 85% of patients
undergoing cataract surgery to be within +/-1.0 D of predicted refractive outcome.5 This was used as our
standard for refractive outcome.
6
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
We defined early glaucomatous damage as when the visual field MD was less than 6 decibels (dB).2 Moderate
or advanced glaucoma cases were defined as MD of 6dB or greater.
Surgical details
Biometry was performed with the IOL Master (Carl Zeiss Meditex, Jena, Germany); all patients were targeted to
achieve emmetropia. The IOL power was calculated using the SRK/T formula with a standardised A constant,
except in axial lengths less than 22mm in which case the Hoffer Q formula was used.6
All procedures were performed by experienced glaucoma surgeons at the Western Eye Hospital. The procedure
was performed under sub-Tenon’s or peribulbar local anaesthesia.
Standard cataract surgery was performed with phacoemulsification (Infinity Vision System; Alcon Laboratories,
Fort Worth, TX, USA) using a 2.8mm temporal clear corneal incision (temporal approach was the surgeon’s
preference), 1 to 2 side-ports and with further incisions as required to facilitate 360-degree ECP treatment.
Foldable acrylic intra-ocular lenses were used, either HOYA PC-60AD or Rayner toric T-flex. The IOL was
inserted in the capsular bag. Using the 20G ECP probe (E2; Endo Optiks, Little Silver, NJ, USA), 360-degrees
photocoagulation was performed under direct visualization from the base to the tip of each ciliary process, until
visible shrinkage and blanching occurred. The treatment energy setting was 0.3 to 0.8 Watts (titrated under
direct visualisation of response) with the treatment duration set to continuous. Intracameral cefuroxime 1.0mg/
0.1ml and subconjunctival dexamethasone 3.3mg/1ml injection (Hospira, Lake Forest, California, USA) was
given at the end of surgery. A standard post-operative regime of 2 hourly dexamethasone and 6 hourly
chloramphenicol drops were given over a 4-6 week period titrated according to post-operative inflammatory
response. Patients were instructed to continue initially with their usual glaucoma agents. All patients were
reviewed by week 1 and then according to the clinical need, typically twice more in the first 6 weeks. The
number of glaucoma agents was reduced if IOP, visual field progress and optic disc assessment remained
satisfactory.
7
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
Statistical analysis
Data are presented as mean ± standard deviation (SD) and frequency (%). The comparison between the target
refraction and the actual post-operative refraction was made using paired t-test. The comparison between the
phaco-ECP group and the control group was made using unpaired t-test. Statistical analysis was performed
using R software (version 3.3.1). A p-value of less than 0.05 was considered statistically significant. Normality
of distribution was tested with Shapiro-Wilk normality test.
8
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
Results
Sixty-two eyes (10 patients had bilateral surgery) out of the 103 eyes, which underwent phaco-ECP at a single
tertiary referral center (The Western Eye Hospital, London, UK) between January 2006 and August 2012, were
included in the study with 62 eyes of 62 patients who had phacoemulsification alone as the control group. The
mean age for the phaco-ECP group and the control group was 76 (SD±12) years and 74 (SD±11) years,
respectively. In the phaco-ECP group, 58.3% of the patients were male and in the control group 37% of the
patients were male. The mean follow-up period for all patients was 21 months (range 2 week to 6 year 2
months). The mean visual field MD was -17.01dB (ranging from -2.44dB to -30.2dB) for the phaco-ECP group.
The pre-operative number of glaucoma agents was 2.7 ± 0.9 for the phaco-ECP group. Fifteen patients (27.8%)
in the phaco-ECP group had previous glaucoma procedures including 13 patients who underwent
trabeculectomy with or without mitomycin C (MMC), 1 Argon laser trabeculoplasty and 1 transcleral
cyclodiode laser. The reasons for exclusions for phaco-ECP group are listed in Table 1.
The majority of patients, 59 eyes (95.2%) in the phaco-ECP group and 61 eyes (98.4%) in phacoemulsification
group, either improved or maintained their visual acuity (Table 2). More than three quarters of the eyes in the
phaco-ECP group (75.8%, n=47) had 2 lines or more improvement in their VA. Three eyes in 2 patients (4.8%)
experienced worsening of the visual acuity, of 3 to 4 Snellen lines, following the surgery. Of these, one patient
who had bilateral phaco-ECP had a history of ocular cicatricial pemphigoid (OCP) with end stage refractory
glaucoma. One patient had advanced age-related macular degeneration (AMD).
In the phaco-ECP group, 90.3% (n=56) of all eyes achieved a refractive outcome within +/-1D of the target
spherical equivalent refraction, whereas in the control group, 100% (n=62) of eyes achieved this (Figure 1). The
difference between the groups is not statistically significant. The refractive outcome of both groups satisfies the
standard established by the Royal College of Ophthalmology 2010 guidelines, which states that at least 85% of
9
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
patients should achieve the refractive outcome within +/-1D of the target spherical equivalent refraction.7
However, when considering the number of cases that achieved the refractive outcome within +/- 0.5D of the
target spherical equivalent refraction in each group, there was a statistically significant difference. Less than
50% of cases (48.4%) in the phaco-ECP group achieved the refractive outcome within +/- 0.5D of the target
spherical equivalent refraction whereas 100% of cases achieved this in the control group (table 3). The mean
difference between the target and the actual post-operative refraction was -0.05D (SD ± 0.7D) in the phaco-ECP
group and was 0.09D (SD ± 0.2D) in the control group. In all three eyes where Rayner T-Flex toric lenses were
used the post-operative refraction within +/-0.5D of the target refraction was achieved (range from -0.25D to
0.375D).
Subgroup analysis of the 6 eyes, which were outside the targeted +/-1D refractive outcome in the phaco-ECP
group, demonstrates the mean difference of -1.2D (SD ±1.68) between the target and the actual refraction. The
majority of these eyes, 83.3% (n=5), displayed myopic shift with post-operative SE ranging between -1.19D and
-2.72D. Only one eye (16.7%) had hypermetropic shift with a SE of +1.57D. Co-morbidities and potential
causes for refractive surprise were studied (Table 4). One eye developed fibrinous uveitis and was treated with
intensive topical steroid. Five eyes had moderate to advanced field defect with mean MD -19.2dB (range from -
11.5dB to -29.8dB). Three eyes had previous trabeculectomy and the other 3 eyes had co-existing age-related
macular degeneration.
In 54 eyes in the phaco-ECP group, the data on IOP, number of glaucoma agents used and history of previous
surgery were obtained. Pre-operative mean IOP was 20.4 ± 6.25 mmHg and the post-operative IOP mean was
14.4 ± 3.95 mmHg. There was an average of 6.0 mmHg, or 29.4% reduction of IOP. Fifty-three eyes (98.1%)
had post-operative IOP equal to or less than 21 mmHg. Seven eyes (13.0%) achieved this without any topical
medication post-operatively. There was an average 29.6% reduction of number of glaucoma agents (from 2.7 to
1.9). Both the reduction in IOP and the number of glaucoma agents were statistically significant (Table 5).
Complications
10
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
Four eyes (6.5%) in the phaco-ECP group developed marked post-operative uveitis and required a more
intensive post-operative topical steroid regime. All of these eyes had VA of 6/6 at their last follow-up. One eye
(1.6%) developed fibrinous uveitis with a pupillary membrane and required YAG laser. One eye with advanced
glaucoma required intracameral tissue plasminogen activator injection with synechiolysis 1 month after phaco-
ECP. The BCVA of hand movement (HM) remained unchanged but this was not unexpected. One patient, with
pre-existing OCP and bilateral juxtafoveal telangiectasia, developed post-operative macular oedema. There were
no cases of hypotony, lens subluxation or dislocation and there was no case that required a capsular tension ring.
No complication occurred in the phacoemulsification group.
11
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
Discussion
In this study, we demonstrated that the refractive outcome of phaco-ECP is comparable to the control group who
underwent phacoemulsification alone with the majority of eyes, 90.3% achieving within +/-1D of the target
refraction using current validated formulae for biometry. This meets the Royal College of Ophthalmology
guideline for cataract surgery.5 Also almost half of our refractive outcome for the eyes in the phaco-ECP group
was within 0.5D of the target; this is similar to the 55% reported in previous phacoemulsification-only study.7 In
our series, all of the eyes in the phacoemulsification only group achieved within 0.5D of the target refraction.
Five of the 6 patients who were not within +/-1D of the target refraction in the phaco-ECP group experienced
myopic shift. This may be explained by possible anterior displacement of the intraocular lens caused by zonular
contraction following cyclophotocoagulation. The average age of the patients who did not achieve the target
refractive outcome was older 81.5 ± 11.5 years compared to the patients who achieved the target refractive
outcome, 76 ± 7.9 years even though the difference was not statistically significant (p=0.61). Zonules may
become weaker due to age and this could contribute to the higher degrees of zonular movement when
cyclophotocoagulation energy was applied to the adjoining ciliary processes, which in turn causes anterior
displacement of the intraocular lens, thus myopic shifts. Another possible explanation is the difference in the
power of cyclophotocoagulation used during phaco-ECP. However as the end-point is the whitening and
shortening of ciliary process, which is observed under visualization, it is unlikely over- or under-treatment
occurred.
12
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
Our group chose to treat 360-degrees of ciliary processes, as we believe it facilitates maximum IOP reduction.
Other groups have also reported this as their preferred treatment protocol.8 Ciliary body rotation via external
indentation, as advocated by some in order to optimise access to additional posterior rows of ciliary processes
and to treat the maximum possible surface area of each ciliary process, was not performed.9 There were no cases
of hypotony.
Regarding our visual acuity outcome, 4.8 % (n=3) experienced worsening of the visual acuity following phaco-
ECP. All three eyes had co-existing macular pathologies including bilateral ocular cicatricial pemphigoid and
post -operative macular oedema in two eyes and one eye with age-related macular oedema. This could be due to
the guarded prognosis in patients with advanced glaucoma due to impaired optic disc function and coexisting
macular pathologies in both eyes. Also these patients who have been treated with multiple topical glaucoma
agents are likely to have suffered from corneal epithelial toxicity, which can compromise the visual outcome. It
has been also noted that 50% of our cohort had visual acuity of 6/9 or better pre-operatively. This may produce
a ceiling effect hence failing to show further VA improvement following phaco-ECP. These factors may explain
why our VA outcome may differ from a previous report by other group,2 where no patients lost BCVA as they
only included the early glaucoma populations.
Limitations of the study
The main limitation of the study is that it is retrospective. A larger prospective series will be useful to determine
whether there are any characteristics of the patients who are more likely to be refractive surprises. In addition,
our post-operative refraction was obtained at various periods after the procedure and was obtained by 2 different
methods (subjective and autorefraction). The change of post-operative refractive SE over time has only been
studied on standard phacoemulsification cases. It demonstrated that there was no significant difference among
the values at 1 week, 1 month, and 4 months.10, 11 However such data does not exist with phaco-ECP and it is
possible that the refractive error may not have stabilised and continues to change over time when our refraction
readings were taken. Also, other parameters maybe useful in future studies to investigate causes of visual loss
and refractive surprise, such as pre- and post-operative macular OCT and corneal endothelial cell count.
13
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
Conclusions
Refractive outcome after phaco-ECP is comparable to phacoemulsification alone. This study suggests that the
refractive outcome may be more variable when the eye undergoes phaco-ECP rather than phacoemulsification
alone. However, the majority of patients will achieve the refractive outcome within 1D of the target spherical
equivalent. Therefore, the intraocular lens power can be selected as for phacoemulsification alone. The authors
recommend that no modification of biometry formulae is necessary for the eyes that undergo phaco-ECP.
Phaco-ECP should be considered as an effective, safe and predictable surgical treatment option for glaucoma
patients with co-existing cataract.
14
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
Figure Captions
Fig. 1 Variance of the difference between the target and the actual spherical equivalent refraction in dioptres for
the phaco-ECP group and the phacoemulsification only control group.
15
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
References
1. Musch DC, Gillespie BW, Niziol LM, Janz NK, Wren PA, Rockwood EJ (2006) Cataract extraction in
the collaborative initial glaucoma treatment study: incidence, risk factors, and the effect of cataract
progression and extraction on clinical and quality-of-life outcomes. Collaborative Initial Glaucoma
Treatment Study Group. Arch Ophthalmol 124(12): 169-700
2. Lindfield D, Ritchie RW, Griffiths MF (2012) 'Phaco-ECP': combined endoscopic
cyclophotocoagulation and cataract surgery to augment medical control of glaucoma. BMJ Open 30:
2(3)
3. Clement CI, Kampougeris G, Ahmed F, Cordeiro MF, Bloom PA (2013) Combining
phacoemulsification with endoscopic cyclophotocoagulation to manage cataract and glaucoma. Clin
Experiment Ophthalmol 41(6): 546-51
4. Olsen T (2007) Calculation of intraocular lens power: a review. Acta Ophthalmologica Scandinavica
85(5): 472-85
5. The Royal College of ophthalmologists. Cataract Surgery Guideline September 2010. [Online].
Available from: http://www.rcophth.ac.uk/
16
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
6. Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL (2011) Formula choice: Hoffer Q,
Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by
partial coherence interferometry. J Cataract Refract Surg 37(1): 63-71
7. Gale RP, Saldana M, Johnston RL, Zuberbuhler B, McKibbin M (2009) Benchmark standards for
refractive outcomes after NHS cataract surgery. Eye (London) 23(1): 149-52
8. Francis BA, Kawji AS, Vo NT, Dustin L, Chopra V (2011) Endoscopic cyclophotocoagulation (ECP)
in the management of uncontrolled glaucoma with prior aqueous tube shunt. J Glaucoma 20 (8), 523–
527
9. Lima FE, Magacho L, Carvalho DM, Susanna R Jr, Avila MP (2004) A prospective, comparative study
between endoscopic cyclophotocoagulation and the Ahmed drainage implant in refractory glaucoma. J
Glaucoma 13(3): 233-7
10. Lake D, Fong K, Wilson R (2005). Early refractive stabilization after temporal phacoemulsification:
what is the optimum time for spectacle prescription? Journal of Cataract & Refractive Surgery
31(9):1845
11. De Juan V, Herreras JM, Pérez I, Morejón Á, Río-Cristóbal A, Martín R, Fernandez I, Rodriguez G
(2013) Refractive stabilization and corneal swelling after cataract surgery. Optom Vis Sci. 90(1): 31-6
17
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
18
412
413
414
415
416
Case exclusion reasonsNumber of
cases
Cases with incomplete data or those that were referred from other centres only for the phaco-ECP procedure
36
Cases with unreliable pre-operative autorefraction due to the low visual acuity (counting finger or worse)
3
Lost to follow-up 1
Case that only had ECP, not phaco-ECP 1
Total number of cases excluded from the study 41
Table 1. Details of case exclusion
Post-operative visual acuity compared Phaco-ECP Phacoemulsific
19
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
to pre-operative visual acuityNumber of eyes
(percentage)
ation alone
Number of eyes
(percentage)
Improved 47 (75.8%) 54 (87.1%)
Same 12 (19.4%) 7 (11.3%)
Worsened 3 (4.8%) 1 (1.61%)
Table 2. Post-operative visual acuity compared to pre-operative visual acuity
Post-operative
refractive outcome
Phaco-ECP Phacoemulsification
alone
P-value
20
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
Number of eyes
(percentage)
Number of eyes
(percentage)(chi-squared)
Within +/-1D of the
target spherical
equivalent
56 (90.3%) 62 (100%) 0.58
Within +/-0.5D of
the target spherical
equivalent
30 (48.4%) 62 (100%) 0.00002
Table 3. Post-operative refractive outcome
Co-morbidities / causes Number of eyes
Moderate to advanced glaucoma* 2
21
451
452
453
454
455
456
457
458
459
460
Age-related macular degeneration with moderate
to advanced glaucoma*2
Anterior chamber fibrinous exudation 1
Age-related macular degeneration 1
Total 6
Table 4. Co-morbidities and causes of refractive outcome outside +/-1D of target refraction (*
average MD -13.25d)
Pre-operative Post-operative P-value
IOP 20.4 ± 6.25 mmHg 14.4 ± 3.95 mmHg 0.0000004
22
461
462
463
464
465
466
467
468
469
470
471
472
Number of glaucoma
agents2.7 ± 0.9 1.9 ± 1.3 0.001
Table 5. Pre- and post-operative IOP and number of glaucoma agents in the phaco-ECP
group
23
473
474
475
476
477
478
24
479