comparison of eus-guided trucut with eus-guided...
TRANSCRIPT
![Page 1: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/1.jpg)
A. Ginès1, G. Fernández-Esparrach1, M. Pellisé1, L. Argüello2, M. Solé3, Ll. Colomo3, O. Sendino1, L. Moura1, A. Gimeno1, A. Mata1, J. Llach1,
JM. Bordas1. 1Endoscopy Unit and 3 Pathology Department. Hospital Clinic. IDIBAPS.
Barcelona. Spain2Endoscopy Unit. Hospital La Fe. Valencia. Spain.
COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED FINE-NEEDLE ASPIRATION
IN SUBEPITHELIAL TUMORS: PRELIMINARY RESULTS OF A
PROSPECTIVE STUDY.
![Page 2: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/2.jpg)
BACKGROUND
� Pathological diagnosis of subepithelial tumors is oftennot possible based on cytology alone.
� Diagnosis of subepithelial tumors must be based onimmunohistochemical analysis, that requieres a larger sample than cytological evaluation alone.
� It has been suggested that a trucut needle would improvethe diagnostic yield of EUS-guided puncture in this settingby providing a core tissue specimen.
![Page 3: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/3.jpg)
To prospectively compare the diagnostic accuracy of EUS-guided trucut needly
biopsy (EUS-TNB) with EUS-guided fine-needle aspiration (EUS-FNA) in the diagnosis of subepithelial tumors.
AIM
![Page 4: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/4.jpg)
PATIENTS
Inclusion criteria
• Diameter of the tumor > 2 cm• Solid lesion• Location in stomach• Prothrombin time >50% and platelet count >50,000
Study population
Consecutive patients diagnosed of a subepithelialtumor sent for EUS evaluation
![Page 5: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/5.jpg)
METHODS
• Patient under conscious sedation.
• EUS-TNB and EUS-FNA of the same lesion (order randomly assigned).
• Needles: 19-gauge trucut biopsy needle and 22-gauge needle.
• On-site cytopathologist:
evaluation of EUS-FNA smear
touch-prep
![Page 6: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/6.jpg)
• As many passes as necessary until a complete cylinder was identified (EUS-TNB) or until the cytopathologistinformed that an adequate specimen was obtained (EUS-FNA)
• Maximum of three passes in both cases
• Diagnosis: based on cytology or histology and immunohistochemical determinations when appropriated
METHODS
![Page 7: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/7.jpg)
22-g needle for EUS-FNA
![Page 8: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/8.jpg)
Tip of the 19-g trucut needle
2 cm tissue tray
cutting sheath
![Page 9: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/9.jpg)
19-g trucut
for EUS-TNBSpring-loaded mechanism
screw-stop lock
adjustment wheel
Firingposition
![Page 10: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/10.jpg)
Endoscopic appearance of a gastric subepithelial tumor
Ultrasonographic appearance of a gastric subepithelial tumor
![Page 11: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/11.jpg)
Trucut tip
EUS-TCB of a gastric subepithelial tumor
![Page 12: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/12.jpg)
FNA TNB
Cytological smear: cluster of spindlecells in a fibrillar matrix. No nuclearatypia (Papanicolau stain,x200)
Core tissue specimen: core ofspindle cell proliferation(H&Ex40)
EUS-FNA cytology vs EUS-TNB histologic cylinder
![Page 13: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/13.jpg)
Immunohistochemical stain for c-kit in cell-block from EUS-FNA
![Page 14: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/14.jpg)
body
body
body
body
body
body
fundus
antrum
body
body
location
3Not possibleInsuficient sample
2GISTMesenchymal t.60x3010
Mesenchymal t.
Mesenchymal t.
Failure
Mesenchymal t.
Failure
Squamous Ca.
Failure
Mesenchymal t.
Mesenchymal t.
histology
EUS-TNB
50x34
230x110
25x21
56x55
46x36
47x45
32x23
26x23
40x38
Size (mm)
1GISTMesenchymal t.1GIST9
2Not possibleMesenchymal t.1GIST8
1GISTMesenchymal t.2-7
2GISTMesenchymal t.1GIST6
3GISTMesenchymal t.--5
1Not doneSquamous Ca.1Not done4
1C-kit negativeIndiferentiate Ca.--3
2Not possibleMesenchymal t.1GIST2
1Not possibleMesenchymal t.3GIST1
passesimmunocytologypassesimmuno
EUS-FNA
RESULTS
58+61 x 37+27 1.5 + 0.7 1.7 + 0.8
![Page 15: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/15.jpg)
RESULTS
5/9 (55%)6/6 (100%)C-KIT DETERMINATION
9/10 (90%)7/10 (70%)DIAGNOSIS
EUS-FNAEUS-TNB
P=NS
P=NS
![Page 16: COMPARISON OF EUS-GUIDED TRUCUT WITH EUS-GUIDED …mafservizi.edinf.com/CMS/images/stories/EGEUS_2007_ppt/Sala500/...Ll. Colomo 3, O. Sendino 1, L. Moura 1, A. Gimeno 1, A. Mata 1,](https://reader031.vdocuments.us/reader031/viewer/2022011809/5cc246c488c993ba588daf7f/html5/thumbnails/16.jpg)
1. The diagnostic accuracy of EUS-TNB and EUS-FNA in subepithelial tumors is good and similar.
2. Determination of c-kit seems to be more feasible in the tissue specimen provided by EUS-TNB.
3. More patients have to be studied before taking definitive conclusions about final accuracy of the two techniques.
CONCLUSION