FIRST CLASS POSTAGE REQUIRED Communications Cooling Solutions nVent HOFFMAN Protects In the fast paced communications industry, continual innovation is a must. Increasing advances in technological breakthroughs have led to more powerful communications systems in more compact designs. As a result of the increased power densities found within these electrical systems, more concentrated heat densities are naturally occurring placing more emphasis on the need to design efficient, effective thermal removal solutions into the communication system. Protecting critical electrical components and systems has become more important than ever in ensuring that you are able to consistently deliver high performing, reliable communication networks that won’t fail. With the demands on communication networks only expected to grow, having a reliable partner to help you protect your critical electrical systems is not only smart business; it’s a must! HOFFMAN’s thermal management solutions, in addition to HOFFMAN electrical enclosures, will give you the assurances needed to protect your sensitive communications equipment, even in the most extreme environments. An unrivaled strategic partnership for the most responsive local service Capabilities For your global needs, HOFFMAN can offer standard, modified or custom cooling and enclosure solutions designed to your specifications. Working with HOFFMAN gives you the confidence of having the best integrated solution in the market so that you complete your project on time, at the best value. HOFFMAN has integrated solutions for OSP With HOFFMAN, you have the right partner to meet your needs. We offer the broadest selection of Cooling and Enclosure solutions in the market along with the best Service & Repair support. HOFFMAN can help you meet every application challenge • Standard Stock Solutions: large selection of standard off the shelf catalog solutions • Modified Standard Stock Solutions: application solutions tailored from standard stock catalog solution platforms • Unique Engineered Solutions: non-standard application solutions created to meet customer specifications Factory-authorized service available around the globe 6,700 AUTHORIZED TECHNICIANS WORLDWIDE Through partnership with Johnson-Northwest, HOFFMAN offers unsurpassed service presence and response from over 570 local service locations in North America with expertise that reaches worldwide. • Factory-authorized expertise for HOFFMAN and McLean models and many competitor models • Extensive reporting capabilities including up-to-date status monitoring • In-stock availability for selected cooling parts • 24/7/365 service availability TELECOM AND CELLULAR TOWERS EQUIPMENT MILITARY COMMUNICATIONS HOMELAND SECURITY SYSTEMS RETURN ADDRESS

Upload: others

Post on 11-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Communications Cooling Solutions...TELECOM AND CELLULAR TOWERS EQUIPMENT MILITARY COMMUNICATIONS HOMELAND SECURITY SYSTEMS RETURN ADDRESS Field-Proven Protection HOFFMAN COOLING SOLUTIONS

FIRST CLASS

POSTAGE REQUIRED

Communications Cooling Solutions

nVent HOFFMAN ProtectsIn the fast paced communications industry, continual innovation is a must. Increasing advances in technological breakthroughs have led to more powerful communications systems in more compact designs. As a result of the increased power densities found within these electrical systems, more concentrated heat densities are naturally occurring placing more emphasis on the need to design efficient, effective thermal removal solutions into the communication system.

Protecting critical electrical components and systems has become more important than ever in ensuring that you are able to consistently deliver high performing, reliable communication networks that won’t fail. With the demands on communication networks only expected to grow, having a reliable partner to help you protect your critical electrical systems is not only smart business; it’s a must!

HOFFMAN’s thermal management solutions, in addition to HOFFMAN electrical enclosures, will give you the assurances needed to protect your sensitive communications equipment, even in the most extreme environments.

An unrivaled strategic partnership for the most responsive local service

CapabilitiesFor your global needs, HOFFMAN can offer standard, modified or custom cooling and enclosure solutions designed to your specifications. Working with HOFFMAN gives you the confidence of having the best integrated solution in the market so that you complete your project on time, at the best value.

HOFFMAN has integrated solutions for OSP

With HOFFMAN, you have the right partner to meet your needs. We offer the broadest selection of Cooling and Enclosure solutions in the market along with the best Service & Repair support.

HOFFMAN can help you meet every application challenge

• Standard Stock Solutions: large selection of standard off the shelf catalog solutions

• Modified Standard Stock Solutions: application solutions tailored from standard stock catalog solution platforms

• Unique Engineered Solutions: non-standard application solutions created to meet customer specifications

Factory-authorized service available around the globe

6,700AUTHORIZED TECHNICIANS WORLDWIDE

Through partnership with Johnson-Northwest, HOFFMAN offers unsurpassed service presence and response from over 570 local service locations in North America with expertise that reaches worldwide.

• Factory-authorized expertise for HOFFMAN and McLean models and many competitor models

• Extensive reporting capabilities including up-to-date status monitoring

• In-stock availability for selected cooling parts

• 24/7/365 service availability

TELECOM AND CELLULAR TOWERS EQUIPMENT MILITARY COMMUNICATIONS HOMELAND SECURITY SYSTEMS

RETURN ADDRESS

Page 2: Communications Cooling Solutions...TELECOM AND CELLULAR TOWERS EQUIPMENT MILITARY COMMUNICATIONS HOMELAND SECURITY SYSTEMS RETURN ADDRESS Field-Proven Protection HOFFMAN COOLING SOLUTIONS

Fiel

d-Pr

oven

Pro

tect

ion

HOFF

MAN

COO

LING

SOL

UTIO

NS F

OR C

RITI

CAL

APPL

ICAT

IONS

Prot

ect y

our e

quip

men

t fro

m d

amag

ing

heat

with

UL®

-Cer

tifie

d co

olin

g, h

eatin

g, a

nd c

limat

e co

ntro

l pro

duct

s fo

r rel

iabl

e eq

uipm

ent o

pera

tion

and

long

er li

fe o

f pro

tect

ed c

ompo

nent

s.

We

mak

e en

ergy

eff

icie

nt, m

aint

enan

ce-fr

iend

ly p

rodu

cts–

all l

ocal

ly s

tock

ed a

nd b

acke

d w

ith o

ne o

f the

larg

est s

ervi

ce o

rgan

izat

ions

in th

e in

dust

ry.

SOLU

TION

S TH

AT S

AVE

MON

EY

AND

POW

ER O

N SY

STEM

S TH

AT

CAN

OPER

ATE

AT O

R AB

OVE

AMBI

ENT

TEM

PERA

TURE

S

FRES

H A

IR E

NC

LOS

UR

E C

OO

LIN

G

DIR

ECT

AIR

CO

OLE

RS

( DA

C)

• Typ

e 3R

rate

d an

d Te

lcor

dia

GR4

87 c

apab

le

• Filt

er o

ptio

ns ra

nge

from

Hyd

roph

obic

to

sta

ndar

d M

ERV

12 F

urna

ce fi

lters

• T

empe

ratu

re c

ontro

lled

with

ala

rm• P

ower

Inpu

t: 48

VD

C

FILT

ER F

AN

S

• Mod

els

from

16

CFM

( 28

M3/

Hr)

to 5

70

CFM

( 970

M3/

Hr)

of a

ir flo

w• I

P 54

dus

t filt

er s

tand

ard.

IP5

5 Z-

filte

r pr

otec

tion

optio

n fo

r add

ed p

rote

ctio

n ag

ains

t moi

stur

e in

filtr

atio

n• O

ptio

nal I

P56

rain

/ w

ash

dow

n sh

roud

• 115

and

230

VAC

50/

60 h

z, 2

4 an

d 48

VD

C po

wer

inpu

t opt

ions

• Hig

h ai

r flo

w m

odel

s w

ith 4

00 /

460

3-ph

ase

VAC

pow

er in

put o

ptio

n• O

ptio

nal s

hrou

d m

aint

ains

Typ

e 12

or

Type

3R

encl

osur

e ra

ting

FAN

TR

AYS

• Enh

ance

s na

tura

l con

vect

ion

airf

low

w

ithin

a c

abin

et w

hen

inst

alle

d w

ith

othe

r 19-

in. r

ack

mou

nted

equ

ipm

ent

• Fan

tray

s av

aila

ble

with

eith

er th

ree

or

six

4-in

. fan

s• I

nclu

des

72-in

. (18

29m

m) p

ower

cor

d w

ith IE

C 32

0 st

anda

rd p

ower

soc

ket

• Pow

er c

ord

plug

s in

to s

tand

ard

115 

VAC 

outle

t• L

ight

ed ro

cker

sw

itch

prov

ides

on-

off

cont

rol

and

indi

cate

s w

hen

fans

are

on

RA

CK-

MO

UN

TAB

LE B

LOW

ERS

• 19-

in. R

ack

Mou

ntab

le• B

rush

ed A

lum

inum

Gril

le• E

xhau

st G

uard

• Pow

er in

put:

115/

230

VAC

SEA

LED

EN

CLO

SU

RE

CO

OLI

NG

ENC

LOS

UR

E H

EAT

ERS

T-S

ERIE

S LA

RG

E C

APA

CIT

Y O

UT

DO

OR

A/C

• UL

List

ed ( s

ome

mod

els

UL 

Reco

gniz

ed)

• Tel

ecor

dia

GR-

487

capa

ble

• Com

pact

foot

prin

t to

min

imiz

e m

ount

ing

spac

e re

quire

d• P

ower

inpu

ts in

clud

e 23

0 an

d 46

0 VA

C

TH

ERM

OEL

ECT

RIC

CO

OLE

RS

• No

refr

iger

ant o

r com

pres

sor

• 60,

100

, and

200

Wat

ts o

f co

olin

g ca

paci

ty• 2

4 an

d 48

VD

C po

wer

inpu

t• O

ptio

ns w

ith a

nd w

ithou

t shr

oud

CLI

MA

GU

AR

D A

IR-T

O-A

IR

OU

TD

OO

R H

EAT

EXC

HA

NG

ERS

• UL

List

ed ( s

ome

mod

els

UL 

Reco

gniz

ed)

• Tel

ecor

dia

GR-

487

capa

ble

• Coo

ling

capa

citie

s ra

ngin

g fr

om

14 W

/°F

– 83

W/°

F• P

ower

inpu

ts in

clud

e 24

VDC,

48

VDC,

11

5 VA

C an

d 23

0 VA

C

SEM

I-C

ON

DU

CTO

R H

EAT

ER

• Mai

ntai

ns a

sta

ble

encl

osur

e te

mpe

ratu

re• 1

0-60

Wat

ts H

eatin

g Pe

rfor

man

ce R

ange

• Bla

ck a

nodi

zed

alum

inum

TOU

CH

-SA

FE H

EAT

ER

• Pro

tect

ele

ctro

nic,

mec

hani

cal

equi

pmen

t fro

m lo

w te

mpe

ratu

res,

co

nden

satio

n, a

nd c

orro

sion

• 10-

50 W

atts

hea

ting

perf

orm

ance

ra

nge

• Hea

ting

elem

ent P

TC re

sist

or

–tem

pera

ture

lim

iting

• Dou

ble

Insu

late

d Pr

otec

tion

• Mou

ntin

g cl

ip fo

r 35m

m D

IN ra

il, EN

60

715

• Ver

tical

mou

nt

ELEC

TR

IC H

EAT

ER

• 100

-130

0 W

atts

hea

ting

perf

orm

ance

rang

e• A

lum

inum

hou

sing

• The

rmos

tat r

ange

adj

usta

ble

from

F to

100

°F (

-18°

C to

38°

C)

OU

TS

IDE

PLA

NT

( OS

P) &

NET

WO

RK

ING

EN

CLO

SU

RES

HO

FFM

AN h

as th

e m

anuf

actu

ring

capa

bilit

ies

and

capa

city

to d

eliv

er p

rove

n, te

sted

and

robu

st O

SP e

nclo

sure

sol

utio

ns fo

r any

siz

e de

ploy

men

t on

any

sche

dule

. An

d th

e ex

perie

nce

to e

nsur

e ou

r enc

losu

res

prov

ide

year

s of

ope

ratio

nal i

nteg

rity

in th

e w

orld

’s m

ost e

xtre

me

envi

ronm

ents

.

CO

MLI

NE

OS

P PA

CK

AG

E, T

YP

E 4X

• Des

igne

d to

mee

t Tel

cord

ia N

EBS™

GR-

487,

GR-

63 a

nd IE

C 48

D • E

IA 3

10-D

with

19

in. s

paci

ng fo

r ra

ck e

quip

men

t • M

eets

BIC

SI T

DM

M, T

enth

Edi

tion,

Cha

pter

7,

Tele

com

mun

icat

ion

Enc

losu

res

( TE)

• C

abin

et is

RoH

S co

mpl

iant

• Sol

ar s

hiel

d he

lps

keep

enc

losu

re in

terio

r co

ol w

hen

cabi

net i

s in

stal

led

outd

oors

and

di

rect

s liq

uids

aw

ay fr

om c

abin

et o

peni

ng• F

oam

-in-p

lace

gas

ket t

hat s

ecur

es a

nd

prot

ects

sen

sitiv

e eq

uipm

ent i

n ou

tdoo

r ap

plic

atio

ns

CO

MLI

NE,

TY

PE

4X

• Des

igne

d to

mee

t Tel

cord

ia N

EBS™

GR-

487,

GR-

63 a

nd IE

C 48

D • L

ight

wei

ght,

corr

osio

n-re

sist

ant a

lum

inum

w

all-m

ount

enc

losu

re p

rovi

de lo

ng-la

stin

g pr

otec

tion

for h

ousi

ng e

lect

rical

com

pone

nts

in e

xtre

me

outd

oor e

nviro

nmen

ts• I

deal

for r

ooft

op o

r tow

er-m

ount

ed

tele

com

mun

icat

ions

app

licat

ions

• Foa

m-in

-pla

ce g

aske

t• C

usto

miz

able

NET

SER

IES

CO

MM

UN

ICAT

ION

AN

D

SER

VER

CA

BIN

ET

• Doo

rs h

ave

key-

lock

ing

hand

les

that

pro

vide

se

curit

y fo

r acc

ess

only

by

auth

oriz

ed

pers

onne

l• G

ener

al p

urpo

se e

cono

mic

al c

abin

et

solu

tion

• Fan

-read

y to

p w

ith in

tegr

al fi

nger

gua

rd• T

este

d to

400

0 lb

. (18

14 k

g) w

ithou

t fai

lure

to

mee

t the

100

0 lb

. (45

4 kg

) rat

ing

PR

OT

EK

• UL

and

NEM

A Ty

pe 4

, 4X

or 1

2• S

ingl

e- o

r dou

ble-

hing

ed m

odel

s av

aila

ble

in

Type

304

sta

inle

ss s

teel

or m

ild s

teel

• Cho

ose

from

sol

id d

oor o

r opt

iona

l win

dow

do

or, m

ade

of .2

5 in

. scr

atch

-resi

stan

t saf

ety

glas

s fo

r vis

ual m

onito

ring

• Opt

iona

l int

egra

l top

sol

ar/d

rip s

hiel

d• P

rem

ium

sea

mle

ss, f

oam

-in-p

lace

gas

ket

prev

ents

con

tam

inan

ts fr

om e

nter

ing

the

cabi

net

• Ide

al fo

r pro

tect

ing

rem

ote

19 in

. net

wor

k eq

uipm

ent i

n co

rros

ive

envi

ronm

ents

FTT

X EN

CLO

SU

RE

• NEM

A Ty

pe 3

, 3R,

4, 4

X, 1

2

• Ava

ilabl

e w

ith s

ingl

e- o

r dua

l-acc

ess

door

s on

fron

t and

rear

for c

onve

nien

t acc

ess

• Sea

mle

ss fo

am-in

-pla

ce g

aske

t sea

ls d

oors

ag

ains

t moi

stur

e an

d du

st• A

vaila

ble

with

or w

ithou

t bat

tery

co

mpa

rtm

ent

• Cab

inet

top

insu

latio

n he

lps

prev

ent t

he

form

atio

n of

con

dens

atio

n an

d re

duce

sol

ar

gain

insi

de th

e ca

bine

t • S

elec

t sta

ndar

d m

odel

s in

clud

e in

tegr

ated

co

olin

g so

lutio

ns

FOR

SPEC

IFIC

PRO

DUCT

IN

FORM

ATIO

N GO

TO:

nV

ent.c

om/H

OFFM

AN

H20

MIT

TH

ERM

OEL

ECT

RIC

D

EHU

MID

IFIE

R

• Con

dens

es m

oist

ure

from

inte

rnal

en

clos

ure

air a

nd s

tand

ing

liqui

ds• R

emov

es 8

oz.

of m

oist

ure

in

24 h

ours

• Ope

rate

s on

24

volt

DC

Pow

er

DU

AL

TH

ERM

OS

TAT

• Tw

o Th

erm

osta

ts in

one

for

cont

rolli

ng b

oth

heat

ing

and

cool

ing 

syst

ems

• Wid

e ad

just

able

tem

pera

ture

rang

e ( 3

2°–

140°

F)• T

herm

osta

tic b

imet

allic

sen

sor

elem

ent

ELEC

TR

ON

IC H

YGR

OT

HER

M

• Sen

ses

and

adju

sts

tem

pera

ture

and

re

lativ

e ai

r hum

idity

leve

ls to

mai

ntai

n at

set

poi

nts

• LED

func

tiona

l dis

play

s• 1

00-2

40 V

AC P

ower

Inpu

t

H20

MIT

VEN

T D

RA

INS

• Dra

ins

accu

mul

ate

wat

er o

ut

of e

nclo

sure

• Air

pres

sure

equ

aliz

er h

elpi

ng to

pr

even

t wat

er a

nd c

onta

min

ants

fr

om e

nter

ing

encl

osur

e • H

elps

redu

ce c

orro

sion

of i

nter

nal

elec

tric

al a

nd e

lect

roni

c co

mpo

nent

s• M

aint

ains

UL

type

ratin

g ( u

p to

U

L 4X

) whe

n pr

oper

ly in

stal

led

AC

CES

SO

RIE

S

©20

18 n

Vent

. All n

Vent

mar

ks a

nd lo

gos

are

owne

d or

licen

sed

by n

Vent

Ser

vice

s G

mbH

or i

ts a

ffilia

tes.

All o

ther

trad

emar

ks a

re th

e pr

oper

ty o

f the

ir re

spec

tive

owne

rs. n

Vent

rese

rves

the

right

to c

hang

e sp

ecifi

catio

ns w

ithou

t not

ice.

PO

ST00

144_

1803