communication solutions for rockwell automation users...collect, store, and analyze data to realize...
TRANSCRIPT
Communication Solutions for Rockwell Automation® Users
A S I A P A C I F I C | A F R I C A | E U R O P E | M I D D L E E A S T | L A T I N A M E R I C A | N O R T H A M E R I C A
www.prosoft-technology.com
Leverage the IIoTCollect, store, and analyze data to realize measureable business improvements.
There’s operational data within nearly every piece of equipment in your business – and you can use it to make changes that will positively affect your facility. ProSoft’s in-chassis modules and standalone gateways have been used for nearly 30 years to connect disparate equipment, the first step on the path to showing ROI from your Connected Enterprise.
After connecting your equipment with a ProSoft solution, you’ll:• Transmit the data to your secure MES or ERP system via an OPC UA gateway. (Psst – ProSoft’s OPC UA Server gateway
supports EtherNet/IP™ as well, ensuring smooth data transmission from your factory floor to your storage space.)
• Then you’ll analyze the data to recognize trends over time. Depending on the area(s) you’d like tofocus on, you could look at information about everything from backlog levels to energy usage. Studythe information to see where changes make the most sense based on your facility’s goals.
• Finally, you’ll take action based on that data, and see if there is a measureable difference from your historical numbers.
THE BEST IIoT STEPSfor your operation
psft.com/DB4
2
www.prosoft-technology.com Check for product availability in your country.
PROSOFT SOLUTIONSfor Secure Remote Connectivity
psft.com/DB6
CASE STUDY Being able to securely troubleshoot through
a Web platform provided flexibility.psft.com/DCF
Secure Remote ConnectivityProSoft’s suite of remote connectivity solutions is designed to help you gain secure, streamlined access to your remote equipment from one cloud-native platform that you can access from anywhere, reducing your support travel costs.
ProSoft Connect Platform• Uses your PC’s operating-system VPN, which minimizes the need for user-installed software
• EasyBridge™ technology enables your PC to act like it is connected directly to a switch on the remote network
• Allows software tools, such as RSWho and Studio 5000, to work without routing
• Virtual Lockout-Tagout™ gives the end user complete control of access to remote equipment
• Power User Plans available for organizations that have multiple projects – organize and secure access to each one
• Multi-layered defense-in-depth approach keeps your data and equipment safe
• No software to install or maintain
Persistent Data Network• Simple, Secure, Managed always-on remote
infrastructure communications network
• Access via ProSoft Connect platform to monitor and troubleshoot each site in your network
GatewaysIndustrial Cellular Gateway (ICX35-HWC)• 4G LTE cellular or wired access via WAN/LAN port;
Ethernet port available for Internet connection or SIM card; monitor via ProSoft Connect
Network Bridge (PLX35-NB2)• Wired remote access; monitor via ProSoft Connect
Data Logger (PLX51-DL-232)• Ideal for remote sites with limited communications
that need to log data
• Can help OEMs identify operational issues and improve OEEData can be downloaded as a .csv file
• Support for 200 tags
• Minimum log interval: 50 milliseconds
Data Logger Plus (PLX51-DLPLUS-232)• Features support for JSON interface, enabling easy exporting of logged data to business CRM systems;
features an integrated webserver to trend variables and upload logged data
3
PWR
NS
ERR
MS
SER
SERIAL
ENET
Cellular GatewayICX35-HWC+
–
ANT A
ANT B
WWAN
SIM
10-30 VDC6W MAX
HMI
3G/4G LTECellular Gateway
DataLogger
DataLogger
PAC/PLC
HMI
PAC/PLC
IT Network
Internet
RemoteAccess
PACCon�guration Software
PLX50 Con�guration Utility
ITDMZ/Firewall
Gateway
CONNECT
www.prosoft-technology.com
Engineering Station
EtherNet/IP™ DH+
PLC-5® or SLC™
FL
RUN
Allen-Bradley
FLT
BATT
FORCE
DH485
Modbus
RUN PROG
SLC 5/03 CPU
F
RU
Allen-Bradley
FLT
BAT
FORCE
DH485
Modbus
RUN PROG
SLC 5/03 CPU
Allen Bradley®Remote I/O™
EtherNet/IP™
EtherNet/IP™I/O Block & Adapter
10 2 3 4 5 6 7
PLC-5® or SLC™
FL
RUN
Allen-Bradley
FLT
BATT
FORCE
DH485
Modbus
RUN PROG
SLC 5/03 CPU
Allen Bradley®Remote I/O™
or DH+
EtherNet/IP™
PLC-5® or SLC™
F
RU
Allen-Bradley
FLT
BAT
FORCE
DH485
Modbus
RUN PROG
SLC 5/03 CPU
PanelView™ Plus
Allen Bradley®Remote I/O™
EtherNet/IP™
PLC-5® or SLC™
F
RU
Allen-Bradley
FLT
BAT
FORCE
DH485
Modbus
RUN PROG
SLC 5/03 CPU
PowerFlex®
89
2
5
0
3
6
7
1
4
4
• Intelligent routing to ControlLogix® or CompactLogix™ from PLC-5®, SLC™, MicroLogix™ controllers
• Direct-to-tag technology simplifies data mapping, reducing configuration time
Legacy Competitive PLC Modernization Solutions
AN-X2-AB-DHRIO Remote I/O EtherNet/IP™ Gateway
• Replace old Remote I/O drives with new drives on EtherNet/IP™ without modifying PLC code
• Replace PanelView™ units on Remote I/O to new PanelView™ Plus 6 models on EtherNet/IP™ without modifying PLC code
• New controllers can utilize existing legacy Allen-Bradley® I/O
• Enables your Remote I/O PLC-5® or SLC™ to communicate with EtherNet/IP™ FLEX™ I/O adapters, giving you a phased migration option when your 1794-ASB spares are gone
Legacy Rockwell Remote I/O and DH+™ Modernization SolutionsModernize your legacy control system in phases with OpEx dollars
Modicon® S908
Modicon® RIO Drop
TI Remote I/O
GENIUS
Genius® I/O Bus
Square D® I/O
Texas Instruments®RIO Rack
Genius® I/O Blocks
ControlLogix®
EtherNet/IP™
SY/MAX I/O
AN-X(2) Family of Gateways
• Enables Allen-Bradley® PAC via EtherNet/IP™ to control I/O devices on legacy networks
• Enables a phase-based approach for migrating legacy control systems
• Monitor mode enables testing & verification of PAC logic before controlling I/O
1761-NET-ENI Replacement – Update Your Legacy DF1 SystemsNeed a 1761-NET-ENI now that it’s been discontinued? The Routing Module can be used in nearly every application as the NET-ENI. Now you can modernize your legacy DF1 control system in phases using your OpEx budget.
DCS MIGRATION SOLUTIONSare also available at psft.com/DB3
CASE STUDY American Castings estimates
they saved over $100,000 in lost production and implementation
time, as well as 140 hours of troubleshooting and rewiring work.
psft.com/DCD
www.prosoft-technology.com
HART SolutionsGain additional diagnostic information from your distributed process equipment – and boost efficiency as a result.
5
Field I/O
Level Transmitter
PumpFlow Control
Valve
PressureTransmitter
TemperatureTransmitter
DifferentialPressure
Transmitter
To SCADA Host
In-Chassis Flow Computer SolutionsFor Multi-Well Pad and LACT Applications
• Supports 8-16 meter runs with 4 streams per meter run for the measurement of hydrocarbon gases and liquids
• In-chassis solution brings data directly into your ControlLogix® or CompactLogix™; helps minimize cabinet space
• Pair with Rockwell Automation’s distributed I/O capability + ProSoft’s wireless radios to reduce wiring to transmitters and I/O devices
• Includes the use of EAFC Manager, a free Windows 7-based tool for configuration, reporting, and monitoring; hourly or daily archives with user-selected data are available
ControlLogix®
CompactLogix™
Field I/O
Level Transmitter
PumpFlow Control
Valve
PressureTransmitter
TemperatureTransmitter
DifferentialPressure
Transmitter
RTU
FlowComputer
PAC
To SCADA Host
Before After
• NMi certified for OIML, WELMEC, and MID type approval (AGA/API)
• No additional licensing fee for liquid meter runs
• Add another AFC card in same chassis if more Meter runs are required
• Secure Data archiving / meter run
• Archive records stored in non-volatile memory in module
• Archive data cannot be altered/changed
• Integration to SCADA with Modbus/Enron Modbus support (Cygnet, Autosol, and FlowCal)
• System designs can support more than 80 metering locations
PAC/RTU/PLC Modbus® TCP/IP or DNP3 TCP/IPor DNP3 UDP
or EtherNet/IP™
4-20 mA HART®
HART®Input-4
Point to Point—Modbus/TCP, DNP3 (TCP/IP and UDP), EtherNet/IPPoint to Multipoint—EtherNet/IP
FIND OUT HOW YOU'LL BENEFIT
psft.com/DCB
CASE STUDY The flow computers helped Pelican Gathering decrease the number of components, minimize their panel space, and streamline integration.
psft.com/DCE
www.prosoft-technology.com
IEDs/RTUs
IEC 61850
Switchgear
Transformer
ControlLogix®
SCADA/DCS
ControlLogix®
E1
E2
ERR APP OK
10/100
LINK/ACT
CONFIG
10/100
LINK/ACT
RX
TX
RX
TX
RESET
ETHERNET APPLICATION PORTS
SERIAL APPLICATION PORTS
ERR APP OK
10/100
LINK/ACT
CONFIG
10/100
LINK/ACT
RX
RX
TX
TX
RESET
ETHERNET APPLICATION PORTS
SERIAL APPLICATION PORTS
P1
P1
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
DIAG
PROFIBUS
SYS
COM
PROFIBUS DP
DP/PA third-party coupler
PROFIBUS PA
EtherNet/IP™
CompactLogix™
Asset ManagementSoftwarePROFIBUS Solutions
• Remote configuration and diagnostics
• Solutions for PROFIBUS DP-V0 and PROFIBUS DP-V1
• Multi-Slave gateway solutions for large data transfers
• Support for PROFIBUS DP Master or PROFIBUS DP Slave connectivity
• Supports PA devices through third-party coupler
• DTM pass-through support
IEC 61850
• The ControlLogix® PAC is able to emulate multiple Intelligent Electronic Devices on an IEC 61850 network
• Add-On Instruction provides logical definitions for I/O module status and control data, easing configuration and maintenance
• ProSoft Discovery Service (PDS) software initially sets the module’s IP address, so you don’t have to change your PC to the default subnet of the module
DNP3 Ethernet Module Features
• Ethernet Client supports up to 40 DNP3 Ethernet server devices such as RTUs, IEDs, and various protection relays
• Up to 20,000 points of data
• DNP3 Ethernet server allows the unit to interface to other client devices such as SCADA and DCS systems
IEC 61850 & DNP3 Solutions
Server Module
ControlLogix® CompactLogix™
Client & Server Module
6
C/C++ SolutionsWhen you need another processor, but don’t want to add a PAC or PC
• Ideal for custom algorithm applications
• Linux Virtual Machine (VM) and C/C++ development environment provided on separate DVD
• VM contains preinstalled toolchain and libraries
• In-chassis solution simplifies your site and brings data directly into your ControlLogix® or CompactLogix™; helps minimize cabinet space
www.prosoft-technology.com
802.11n (abgn) Fast Industrial Hotspots• Ultra-Fast access point switchover times of less than 10 ms are perfect for applications such
as automated storage-retrieval systems, AGVs, and automotive skillet lines
• EtherNet/IP™ embedded object and Modbus® agent support lets users get radio diagnostics into their PAC/PLC, where the information can be analyzed and acted upon, helping to reduce downtime
• WPA/WPA2-Personal (PSK, AES and/or TKIP); WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, AES and/or TKIP)
• Secure digital configuration storage for quick field replacement
• Radios support wireless safety Ethernet networks, ideal for automated material handling applications
Point I/O
Drive
HMI
RepeaterServer
Control Room
Access Point
Repeater Repeater
ControlLogix®
MIMO Antenna
MIMO AntennaMIMO Antenna
ControlLogix®
VideoCamera SerialEtherNet/IP™
MIMO Antenna
Mobile Worker
Modbus® RTU(to Modbus TCP/IP Host)
CompactLogix™
Point I/O
Drive
PLC
Point I/O
Drive
PLC
Radiating Cable
7
802.11abgn Wireless Plant Architecture
• 2.4 GHz or 5 GHz High-Speed Wireless Network
2.4 GHz and 5 GHz High-Power Industrial Hotspots are also available for longer-distance applications.
Automotive Skillet Line Communication AGV Communication
www.prosoft-technology.com
Control Room
8
Features
• Special coaxial shield design uses slots to radiate RF Signals
• Available in variable lengths
• Pre-assembled cable for easy installation
• Frequency Range: 2.4 GHz, 5 GHz to 6 GHz
Benefits
• Wireless signal more stable in terms of response time – useful in communicating with I/O
• Used in metallic environments, rotating/spinning machines, conveyors, AGV, warehousing, and more
Radiating Cable 2.4 and 5 GHz BandActing as a long, flexible antenna, Radiating Cable is an alternative to traditional RF antenna systems.
Rotating Equipment
Control Room
EtherNet/IP™
CompactLogix™
RLX2-IHNFMaster
Radiating Cable(replaces slip-ring)
EtherNet/IP™
RLX2-IHNFRepeater
Onboard Control Panel Inside Rotating Equipment
Point I/O
• IP67 water/dust rated
• Designed for extreme temperatures (-40° to +70°C), high vibration/shock and hazardous locations (UL C1D2, ATEX Zone 2)
• Ultra-Fast Roaming with under 10 ms switchover times maintains connections for moving machines/platforms
802.11n (abgn) Fast Watertight Industrial Hotspots
• Power over Ethernet (PoE)
• QoS and VLAN for optimum traffic management
• WPA/WPA2-Personal (PSK, AES and/or TKIP)
• WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, AES and/or TKIP)
HOW TO BENEFITfrom radiating cable
psft.com/CXL
www.prosoft-technology.com
• Bi-directional
• 868 MHz, 900 MHz or 2.4 GHz
• Each radio can connect up to 16 I/O modules
• Available as Analog I/O 0-10 V, Analog I/O 4-20 mA & Digital/Discrete I/O
Modbus
PLC Multi-PointMeter Potentiometer
SwitchSwitch
LampLamp
Point-Point
SCADA
Network-wide Access• PLC Programming• HMI Data• Diagnostics
Repeater/Remote
Remote
Master
Remote
CompactLogix™
HMI
ControlLogix®
CompactLogix™
900-928 MHz or 2.4 GHz
• License-free wireless communications for Ethernet devices
• Integrated Repeater Mode to extend range and work around obstructions
• Up to 1.1 Mbps RF data rate
• Smart Switch enables automatic peer-to-peer packet routing and optimizes RF performance
• ControlScape radio management software provides configuration and online diagnostics
Ethernet Frequency Hopping RadiosAvailable in 900 Mhz or 2.4 Ghz
Wireless I/OWhat would you monitor if you didn’t have to worry about the cost of running wire?
Whether you have a point-to-point application or many distributed I/O devices, our Wireless I/O solutions are a great alternative to running long wire runs. Eliminate trenching, running conduit, and the need for permits. The system can be expanded as your I/O needs grow.
9
www.prosoft-technology.com
Ethernet and Serial Gateway SolutionsProSoft Technology’s stand-alone, DIN-rail mounted industrial gateways provide a means to read or write data from devices on dissimilar protocols. All gateways come with our ProSoft Discovery Service feature. With PDS, you don’t have to change your PC to the default subnet of the module, saving you time during setup.
ASCII
Weigh Scale SCADA/DCSBarcodeReader
EtherNet/IP™
HMIPressure Valve
SCADA/DCSCompactLogix™ L3 MicroLogix™ 1100CompactLogix™ L1
Power Monitors
Modbus® Serial Modbus® TCP/IP
PLC
Siemens® Industrial Ethernet
PLC
CompactLogix L18ERM
RUN
FORCE
I/O
OK SD
LINK 2
LINK 1
NS
00:00:BC:68:0E:29
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
ETHP1P2CFGBPOK
ETHP1P2CFGBPOK
• Gateways with two Ethernet ports allow you to isolate networks, passing only the data you want between devices
• EtherNet/IP gateways support multiple I/O connections for fast real-time data
• Remote configuration and diagnostics via Ethernet
• SD Card slot for disaster recovery of configuration data
• Up to four Serial ports
IEC 61850 Gateway Features
• Fast, real-time data transfers with a maximum of 10,000 bytes in and 9,920 out (PLX82) or 5,000 bytes in and 4,960 out (PLX81)
• Polls up to 20 IEC 61850 server devices
• Application-specific Add-On Instructions are automatically generated
• IEC 61850 IED tags are created in your Studio 5000®/RSLogix 5000™ Project, reducing configuration time and errors
RESET
LINK/ACT
EtherNet/IP PROFINET
RESERVED
LINK
SYSSFBF
100 Mbit RX/TX
MS NS
CFG ERR
PWRFLT
PLX82-EIP-PNC
EtherNet/IP PROFINET
20.2.20.2Drive
20.2.20.3HMI
20.2.20.110.1.10.1
10.1.10.3
PROFINET I/O Devices20.2.20.4 20.2.20.5 20.2.20.6
EtherNet/IP to PROFINET Gateways
Controller and Device versions
Building Automation Gateways
EtherNet/IP™BACnet® / LonWorks®
Building AutomationGateway
Boiler
Air Compressor ControlLogix®
Chiller
10
PROFIBUS DP
& many other
protocols are
also available.
www.prosoft-technology.com
Modbus®
Flow Devices Drives PowerMeasurement
ActuatedValves
Loop Controllers
Master and Slave
SCADA/DCS
Modbus®CompactLogix™ L2
Relay
CompactLogix L24ERQBFC1BRUN
FORCE
I/O
OK SD
LINK 2
LINK 1
NS
COM
M A
DAPT
ER
Client and Server
AC Drive PLCPower RelayFlow Device
Modbus® TCP/IP
SCADA/DCS
SCADA/DCS
CompactLogix™ L3
Flow DevicePower Relays
PLC
CompactLogix L36ERMRUN
FORCE
I/O
OK
NS
LINK 1
LINK 2
SD
COM
M A
DAPT
ER
Modbus® TCP/IP
11
Serial & Ethernet Modbus® SolutionsModbus® TCP/IP
• Fast Multi-Server/Multi-Client capabilities
• Add-On Instruction (AOI) reduces configuration effort and simplifies maintenance
Modbus® Serial
• Module configuration stored within the Studio 5000®/RSLogix™ 5000 project (ACD file) for simplified disaster recovery
• Add-On Profile (AOP) improves integration into Studio® 5000®/RSLogix™ 5000
• Add-On Instruction (AOI) reduces configuration effort and simplifies maintenance
Scalable Modbus® & Modbus® TCP Solutions for CompactLogix™
• Enhanced modules allow up to 10,000 I/O words
• Lite modules allow up to 240 I/O words
• Integrated Modbus® Serial communications in 1734 Point I/O™ applications
Mod
el
900
MHz
FH
Ethe
rnet
Rad
io 2
.4 G
Hz F
H
Ethe
rnet
Rad
io80
2.11
abgn
W
eath
erpr
oof
Indu
stria
l Hot
spot
802.
11ab
gn F
ast
Indu
stria
l Hot
spot
802.
11g
Hi
gh-P
ower
In
dust
rial H
otsp
ot
802.
11a
Hi
gh-P
ower
In
dust
rial H
otsp
ot
Indu
stria
l Cel
lula
r Ga
tew
ayPo
int-
to-P
oint
W
irele
ss I/
OM
ulti-
Poin
t W
irele
ss I/
O
RLX2
-IFH9
ERL
X2-IF
H24E
RLX2
-IHNF
-W(C
)RL
X2-IH
NFRL
X2-IH
GRL
X2-IH
AIC
X35-
HWC
BM-x
xx0-
RM1K
BM-x
xxx-
GM1K
Feat
ures
& S
peci
ficat
ions
Devi
ce C
onne
ctiv
ityEth
ernet/
Seria
lEth
ernet/
Seria
lEth
ernet
Ethern
et/Se
rial
Ethern
et/Se
rial
Ethern
et/Se
rial
Ethern
et/Se
rial
Mod
bus®
Seria
l
Freq
uenc
y Ba
nd(s
)90
2-92
8 MHz
2.4 GH
z2.4
& 5 G
Hz2.4
& 5 G
Hz2.4
GHz
5 GHz
Cellu
larSe
vera
l freq
uenc
ies
avail
able
Seve
ral fr
eque
ncies
av
ailab
le
Regi
ons
Unlic
ense
d
Use
Allo
wed
North
Ameri
ca,
Latin
Ameri
ca,
Austr
alia,
Ne
w Ze
aland
Globa
lGlo
bal
Globa
l
North
Ameri
ca,
Latin A
merica
, Au
stralia
, New
Zea
land, M
iddle E
ast
North
Ameri
ca,
Latin A
merica
, Au
stralia
, New
Zea
land, M
iddle E
ast
Globa
lNo
rth Am
erica
, Eur
ope,
Austr
alia,
Midd
le Ea
stNo
rth Am
erica
, Eur
ope,
Austr
alia,
Midd
le Ea
st
Wire
less
Tech
nolo
gyFre
quen
cy
Hopp
ingFre
quen
cy
Hopp
ingIEE
E 802
.11ab
gnIEE
E 802
.11ab
gnIEE
E 802
.11g
IEEE 8
02.11
a4G
LTE C
ellula
r HSP
AFre
quen
cy
Hopp
ingFre
quen
cy
Hopp
ing
Max
Out
door
Ran
ge
(mile
s/km
)30
mi /
48 km
15 m
i / 24
km5 m
i /8 km
5 mi /8
km20
mi /
30km
5 mi /
8 km
Unlim
ited
1-4 m
i / 1.6
-6.4
km5-
30 m
i / 8-
48 km
Fast
Roa
min
gN/
AN/
AYe
sYe
sYe
sYe
sN/
AN/
AN/
A
Repe
ater
Mod
eYe
sYe
sYe
sYe
sYe
sYe
sN/
AN/
AN/
A
Max
RF
Data
Rat
e1.1
Mbp
s1.1
Mbp
s30
0 Mbp
s30
0 Mbp
s54
Mbp
s54
Mbp
sN/
AN/
AN/
A
Secu
rity/
Encr
yptio
nPro
prieta
ry FH
SS /
128 b
it AES
Propri
etary
FHSS
/12
8 bit A
ES80
2.11i
/ 128
bit
AES
802.1
1i / 1
28 bi
t AE
S80
2.11i
/ 128
bit
AES
802.1
1i / 1
28 bi
t AE
S
Intern
al Fir
ewall
, ProS
oft
Conn
ect V
PN, O
penV
PN,
IPSec
Propri
etary
FHSS
/12
8 bit A
ESPr
oprie
tary
FHSS
/ 12
8- to
25
6-bi
t AES
RF B
ased
IGM
P Qu
eryi
ngN/
AN/
AYe
sYe
sYe
sYe
sN/
AN/
AN/
A
Self-
Heal
ing
Netw
ork
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
N/A
Adva
nced
Dia
gnos
tics
(sig
nal
stre
ngth
LED
s, w
eb s
erve
r, ne
twor
k m
anag
emen
t sof
twar
e,
OPC
tag
serv
er, S
NMP)
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
N/A
Haza
rdou
s Lo
catio
n Ap
prov
als
Class
1, Div
2Cla
ss 1,
Div 2
/At
ex Zo
ne 2
Class
1, Div
2/At
ex Zo
ne 2
(WC)
Class
1, Div
2/ At
ex Zo
ne 2
Class
1, Div
2/At
ex Zo
ne 2
Class
1, Div
2/At
ex Zo
ne 2
Class
1, Div
2Cla
ss 1,
Div 2
/ At
ex Zo
ne 2
Class
1, Div
2 /
Atex
Zone
2 / C
1D2
Outd
oor/
Was
h Do
wn
Rate
d M
odel
N/A
N/A
IP67
N/A
N/A
N/A
N/A
N/A
N/A
Wire
less
App
licat
ions
Long
-Ran
ge S
CADA
Yes
Yes
N/A
N/A
Yes
Yes
Yes
N/A
N/A
Shor
t-Ra
nge
SCAD
AYe
sYe
sYe
sYe
sYe
sYe
sYe
sN/
AN/
A
Mob
ile W
orke
r (W
i-Fi)
N/A
N/A
Yes
Yes
Yes
Yes
N/A
N/A
N/A
Ethe
rNet
/IP™
Obj
ect
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Ethe
rNet
/IP™
Impl
icit
Mes
sagi
ng
(Hig
h-Sp
eed
IO)
N/A
N/A
Yes
Yes
Yes
Yes
N/A
N/A
N/A
Seria
l DF1
, ASC
II,
Mod
bus®
, DNP
3, e
tc.
Yes (
enca
psula
tion)
Yes
(enca
psula
tion)
N/A
Yes
(enca
psula
tion)
Yes
(enca
psula
tion)
Yes
(enca
psula
tion)
Yes
(enca
psula
tion)
N/A
N/A
Vide
oSn
apsh
ots On
lySn
apsh
ots On
lyFa
st Fra
me Ra
teFa
st Fra
me Ra
teYe
sYe
sYe
sN/
AN/
A
Chec
k fo
r pro
duct
ava
ilabi
lity
in y
our c
ount
ry.
12 www.prosoft-technology.com
Wireless Comparison Product Selection Chart
Platform ControlLogix® CompactLogix™ or MicroLogix™ 1500
Point I/O
Protocol/Application
AGA/API Gas & Liquid Flow Computer MVI56E-AFC MVI69E-AFC
Moore APACS+ I/O CLX-APACS
ASCII MVI56E-GSCMVI56E-GSCXT
MVI69-GSC
BASIC MVI56-BAS
‘C’ Programmable MVI56E-LDM
DF1 MVI56-DFCMR
DNP3 Serial MVI56-DNP MVI69-DNP
DNP3 Ethernet MVI56E-DNPNET MVI69-DNPSNET
EtherNet/IP™ MVI69-DFNT
FA Control/Network MVI56E-FLN
Fisher PROVOX Control Bus I/O CLX-PVX
GE Ethernet Global Data MVI56-EGD MVI69-EGD
Generic Ethernet ASCII MVI56-GEC MVI69-GEC
Honeywell® IPC-620 Serial I/O Bus CLX-422-IPC
IEC 60870-5-101 Slave MVI56-101S MVI69-101S
IEC 60870-5-101 Master MVI56-101M
IEC 60870-5-104 Server MVI56-104S MVI69-104S
IEC 61850 Server MVI56E-61850S
Limitorque Master MVI56-LTQ
Modbus® SerialMVI56E-MCM
MVI56E-MCMRMVI56E-MCMXT
MVI69E-MBS *MVI69L-MBS *
ILX34-MBS232ILX34-MBS485
Modbus® Plus MVI56-MBP
Modbus® TCP/IP
MVI56E-MNETMVI56E-MNETCMVI56E-MNETR
MVI56E-MNETCRMVI56E-MNETXT
MVI69E-MBTCP *MVI69L-MBTCP *
PROFIBUS DP Master MVI56-PDPMV1 ILX69-PBM *
PROFIBUS DP Slave MVI56-PDPS ILX69-PBS *
Siemens® 3964R MVI56-S3964R MVI69-S3964R
Siemens® Industrial Ethernet MVI56E-SIE
* CompactLogix™ ONLY
Have a legacy product that's no longer on these charts?
ProSoft can help you migrate to a newer
solution with expanded functionality.
Many of ProSoft's in-chassis and gateway modules for Rockwell Automation systems feature Add-On Instructions or Add-On Profiles to help you increase efficiency and reduce configuration. Learn more: psft.com/DCC
Learn more about solutions for legacy controllers at
psft.com or by contacting your local ProSoft office.
13www.prosoft-technology.com
In-Chassis Product Selection Chart
Prot
ocol
/App
licat
ion
Appl
icat
ion
/ Pro
toco
lAl
len-
Brad
ley®
Re
mot
e I/O
™AS
CII
‘C’ P
rogr
amm
able
Se
rial
DF1
Mas
ter/
Slav
eDN
P3 S
eria
lDN
P3 E
ther
net
Ethe
rNet
/IP™
HART
® M
ulti-
drop
(4
cha
nnel
s)
Alle
n-Br
adle
y® R
emot
e I/O
™52
10-D
FNT-R
IO
ASCI
I51
02-D
FCM-
ASCII
3PL
X31-
EIP-A
SCII
PLX3
1-EIP
-ASC
II4
BACn
et®
/IPPS
-QS-1
010-
0781
(250
Point
)PS
-QS-1
510-
0781
(500
Point
)PS
-QS-1
010-
0780
(250
Point
) PS
-QS-1
510-
0780
(500
Point
)
BACn
et®
MS/
TPPS
-QS-1
010-
0781
(250
Point
)PS
-QS-1
510-
0781
(500
Point
)PS
-QS-1
010-
0780
(250
Point
PS
-QS-1
510-
0780
(500
Point
)
DF1
Mas
ter/
Slav
e51
02-D
FS3-
DFM
5102
-MCM
4-DF
CM4
PLX5
1-DL
-232
5102
-DNP
M-DF
CM3
5102
-DNP
S-DFC
M3
PLX5
1-DF
1-EN
IPL
X51-
DF1-
MSG
5202
-DFN
T-DFC
M4
DNP3
Ser
ial
5102
-DNP
M-DF
CM3
5102
-DNP
S-DFC
M352
01-D
FNT-D
NPM
5201
-DFN
T-DNP
S
DNP3
Eth
erne
t52
01-D
FNT-D
NPSN
ETPL
X51-
HART
-4I
Ethe
rNet
/IP™
5210
-DFN
T-RIO
PLX3
1-EIP
-ASC
IIPL
X31-
EIP-A
SCII4
PLX5
1-DF
1-EN
I52
02-D
FNT-D
FCM4
PLX5
1-DF
1-EN
IPL
X51-
DF1-
MSG
5201
-DFN
T-DNP
M52
01-D
FNT-D
NPS
5201
-DFN
T-DNP
SNET
PLX5
1-DL
-232
PL
X35-
NB2
PLX5
1-HA
RT-4
I
HART
® A
nalo
gPL
X51-
HART
-4I
PLX5
1-HA
RT-4
I
HART
® M
ulti-
drop
PL
X51-
HART
-4I
PLX5
1-HA
RT-4
I
IEC
6087
0-5-
101
Slav
e51
02-D
FCM3
-101
S
IEC
6087
0-5-
104
Serv
er52
01-D
FNT-1
04S
IEC
6185
0PL
X81-
EIP-6
1850
PLX8
2-EIP
-618
50
LonW
orks
™PS
-QS-1
011-
0783
(250
Point
)PS
-QS-1
511-
0783
(500
Point
)PS
-QS-1
011-
0783
(250
Point
)PS
-QS-1
511-
0783
(500
Point
)51
07-M
CM-H
ART
Met
asys
® N
2PS
-QS-1
010-
0782
(250
Point
) PS
-QS-1
510-
0782
(500
Point
)PS
-QS-1
010-
0782
(250
Point
) PS
-QS-1
510-
0782
(500
Point
)
Mod
bus®
Ser
ial
5102
-MCM
-ASC
II351
02-M
CM4-A
DM4
5102
-DNP
M-MC
M351
02-D
NPS-M
CM3
5201
-DNP
SNET
-MCM
5202
-DNP
SNET
-MCM
4PL
X31-
EIP-M
BSPL
X31-
EIP-M
BS4
PLX5
1-HA
RT-4
I
Mod
bus®
TCP
/IP52
10-M
NET-R
IO52
01-M
NET-A
SCII 5
202-
MNET
-AS
CII4
5202
-MNE
T-ADM
452
01-M
NET-D
FCM
5202
-MNE
T-DFC
M452
01-M
NET-D
NPM
5201
-MNE
T-DNP
S52
01-M
NET-D
NPSN
ET
PLX3
1-EIP
-MBT
CPPL
X32-
EIP-M
BTCP
PLX3
2-EIP
-MBT
CP-U
A
5507
-PDP
S-HAR
T
OPC
UAPL
X32-
EIP-M
BTCP
-UA
PROF
IBUS
DP
5105
-ASC
II-PD
PS51
04-D
FCM
PDPM
5105
-DFC
M-PD
PS51
05-D
NPS-P
DPS
5205
-DNP
SNET
-PDP
S52
04-D
FNT-P
DPMV
152
05-D
FNT-P
DPS
PROF
INET
PL
X31-
EIP-P
NDPL
X32-
EIP-P
NDPL
X82-
EIP-P
NC
Siem
ens®
Indu
stria
l Eth
erne
tPL
X31-
EIP-SI
EPL
X32-
EIP-SI
E
14 www.prosoft-technology.com
Stand-Alone Gateways Product Selection Chart
Prot
ocol
/App
licat
ion
Appl
icat
ion/
Prot
ocol
HART
®
Mul
ti-dr
op
(8 c
hann
els)
IEC
6087
0-5-
101
Slav
eIE
C 60
870-
5-10
4 Se
rver
Mod
bus®
Ser
ial
Mod
bus®
Plu
sM
odbu
s® T
CP/IP
OPC
UAPR
OFIB
US D
P M
aste
rPR
OFIB
US D
P
Slav
ePR
OFIN
ET
Alle
n-Br
adle
y® R
emot
e I/O
™52
10-M
NET-R
IO
ASCI
I51
02-M
CM-A
SCII3
5301
-MBP
-ASC
II53
02-M
BP-A
SCII4
5201
-MNE
T-ASC
II52
02-M
NET-A
SCII4
5105
-ASC
II-PD
PS
BACn
et®
/IPPS
-QS-1
010-
0757
(250
Point
)PS
-QS-1
510-
0757
(500
Point
)PS
-QS-1
010-
0757
(250
Point
)PS
-QS-1
510-
0757
(500
Point
)
BACn
et®
MS/
TPPS
-QS-1
010-
0757
(250
Point
)PS
-QS-1
510-
0757
(500
Point
)PS
-QS-1
010-
0757
(250
Point
)PS
-QS-1
510-
0757
(500
Point
)
DF1
Mas
ter/
Slav
e51
02-D
FCM3
-101
S51
02-M
CM4-
DFCM
453
01-M
BP-D
FCM
5302
-MBP
-DFC
M452
01-M
NET-D
FCM
5202
-MNE
T-DFC
M451
04-D
FCM-
PDPM
5105
-DFC
M-PD
PS
DNP3
Ser
ial
5102
-DNP
M-MC
M351
02-D
NPS-M
CM3
5301
-MBP
-DNP
S52
01-M
NET-D
NPM
5201
-MNE
T-DNP
S51
04-D
NPS-P
DPM
5105
-DNP
M-PD
PS51
05-D
NPS-P
DPS
DNP3
Eth
erne
t52
01-D
NPSN
ET-M
CM52
01-M
NET-D
NPSN
ET52
05-D
NPSN
ET-P
DPS
Ethe
rNet
/IP™
5201
-DFN
T-104
SPL
X31-
EIP-M
BSPL
X31-
EIP-M
BS4
5303
-MBP
-DFN
T
PLX3
1-EIP
-MBT
CPPL
X32-
EIP-M
BTCP
PLX3
2-EIP
-MBT
CP-U
A
PLX3
2-EIP
-MBT
CP-U
A52
04-D
FNT-P
DPM
5205
-DFN
T-PDP
SPL
X31-
EIP-P
NDPL
X32-
EIP-P
NDPL
X82-
EIP-P
NC
HART
® A
nalo
gPL
X51-
HART
-4I
HART
® M
ulti-
drop
(4
cha
nnel
s)51
07-M
CM-H
ART
5307
-MBP
-HAR
TPL
X51-
HART
-4I
5507
-PDP
S-HAR
T
IEC
6087
0-5-
101
Slav
e51
02-M
CM3-
101S
5201
-MNE
T-101
S51
05-1
01S-P
DPS
IEC
6087
0-5-
104
Serv
er52
01-1
04S-M
CM
5202
-104
S-MCM
453
03-M
BP-1
04S
5201
-MNE
T-104
S
IEC
6185
0PL
X81-
MNET
-618
50PL
X82-
MNET
-618
50
LonW
orks
™PS
-QS-1
011-
0154
(250
Point
)PS
-QS-1
511-
0154
(500
Point
)PS
-QS-1
011-
0154
(250
Point
)PS
-QS-1
511-
0154
(500
Point
)
Met
asys
® N
2PS
-QS-1
010-
0117
(250
Point
)PS
-QS-1
510-
0117
(500
Point
)PS
-QS-1
010-
0117
(250
Point
)PS
-QS-1
510-
0117
(500
Point
)
Mod
bus®
Ser
ial
5127
-MCM
-HAR
T51
02-M
CM3-
101S
5201
-104
S-MCM
5202
-104
S-MCM
4
5102
-MBS
3-MB
M51
02-M
CM4-
DFCM
4PL
X51-
DL-2
32
5301
-MBP
-MCM
5302
-MBP
-MCM
451
04-M
CM-P
DPMV
151
05-M
CM-P
DPS
PLX3
1-PN
D-MB
SPL
X31-
PND-
MBS4
Mod
bus®
Plu
s53
03-M
BP-M
NET
5305
-MBP
-PDP
S
Mod
bus®
TCP
/IP52
01-M
NET-1
01S
5201
-MNE
T-104
S,
5303
-MBP
-MNE
TPL
X51-
DL-2
32PL
X32-
EIP-M
BTCP
-UA
5204
-MNE
T-PDP
M52
05-M
NET-P
DPS
PLX3
1-MB
TCP-
PND
PLX3
2-MB
TCP-
PND
PLX8
2-M
BTCP
-PNC
OPC
UAPL
X32-
EIP-M
BTCP
-UA
PROF
IBUS
DP
5105
-101
S-PDP
S52
05-1
04S-P
DPS
5105
-MCM
-PDP
S53
04-M
BP-P
DPMV
153
05-M
BP-P
DPS
5204
-MNE
T-PDP
MV1
5205
-MNE
T-PDP
S
PROF
INET
PL
X31-
PND-
MBS
PLX3
1-PN
D-MB
S4
PLX3
1-MB
TCP-
PND
PLX3
2-MB
TCP-
PND
PLX8
2-M
BTCP
-PNC
Siem
ens®
Indu
stria
l Eth
erne
tPL
X31-
MBTC
P-SIE
PLX3
2-MB
TCP-S
IE
15www.prosoft-technology.com
Stand-Alone Gateways Product Selection Chart
Worldwide Offices
CATALOG_RA_2019_EN
Asia PacificRegional OfficePhone: [email protected] spoken: Bahasa, Chinese, English, Japanese, Korean
REGIONAL TECH SUPPORT [email protected]
North Asia (China, Hong Kong)Phone: [email protected] spoken: Chinese, English
REGIONAL TECH SUPPORT [email protected]
Southwest Asia (India, Pakistan)Phone: [email protected] spoken: English, Hindi, Urdu
Australasia (Australia, New Zealand)Phone: [email protected] spoken: English
Southeast Asia (Singapore, Indonesia, Philippines Brunei, Myanmar, Cambodia & Laos)Phone: [email protected] spoken: English, Bahasa,
Northeast & Southeast Asia (Japan, Taiwan, Thailand, Vietnam, Malaysia)Phone: [email protected] spoken: English, Chinese, Japanese
Korea Phone: [email protected] spoken: English, Korean
Europe / Middle East / AfricaRegional OfficePhone: +33.(0)[email protected] spoken: French, English
REGIONAL TECH SUPPORT [email protected]
Middle East & AfricaPhone: [email protected] spoken: Hindi, English
REGIONAL TECH SUPPORT [email protected]
North Western Europe(UK, IE, IS, DK, NO, SE)Phone: +44.(0)[email protected] spoken: English
Central & Eastern Europe, [email protected] spoken: Polish, English
Russia & [email protected] spoken: Russian, English
Austria, Germany, SwitzerlandPhone: +49.(0)[email protected] spoken: German, English
BeNeLux, France, North AfricaPhone: +33.(0)[email protected] spoken: French, English
Mediterranean CountriesPhone: [email protected] spoken: Italian, English, Spanish
Latin AmericaBrazil, Argentina, UruguayPhone: [email protected] spoken: Portuguese, English, Spanish
REGIONAL TECH SUPPORT [email protected]
MexicoPhone: [email protected] spoken: Spanish, English
REGIONAL TECH SUPPORT [email protected]
Andean Countries, Central America, Caribbean, Chile, Bolivia, Paraguay Phone: [email protected] spoken: Spanish, English
REGIONAL TECH SUPPORT [email protected]
North AmericaRegional OfficePhone: [email protected] spoken: Spanish, English
REGIONAL TECH SUPPORT [email protected]
© 2001–2019by ProSoft Technology, Inc.All rights reserved.
www.prosoft-technology.com
Tech SupportProSoft Technology's technical support is unparalleled in the industrial automation industry. To continue our world-class technical support, we have opened offices in most time zones in an effort to support our customers at a local level. See Regional Tech Support contact information above.