communication and information systems for harsh environments€¦ · •hands-free conversation on...
TRANSCRIPT
Page 1
ms Neumann Elektronik GmbH
Communication and Information Systems for Harsh Environments
Modern Fault Tolerant Scalable Unlimited
ms NEUMANN ELEKTRONIK GmbH
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
Page 2
ms NEUMANN ELEKTRONIK GMBH
● Company founded in 1948 as „Neumann Elektronik GmbH“
● Acquisition by Mattig Schauer in 2004 and renamed to
„ms Neumann Elektronik GmbH“
The
Company
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 3
ms NEUMANN ELEKTRONIK GMBH
● Managing directors: Jörg Michhöfer
● Production site in Germany
● Worldwide marketing, sales and support
The
Company
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 4
One System – One Partner Sy
stem
sol
utio
ns &
pro
duct
s Warning systems
Evacuation
systems
Hazard alarm
systems
Voice alarm
centres
Emergency call
applications
Telephone
applications
Call stations
Loudspeakers
Amplifiers Engi
neer
ing
Planning
Consulting
Project
management
Site surveys
Integration &
migration
Acoustic and
electric
studies
Generating of
text and alarm
signals Serv
ice
Installation &
commissioning
Maintenance &
support
Service hotline
24h
Remote
maintenance
Remote
configuration
Emergency
service
Training
The
Company
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 5
DS-6
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 6
DS-6
System
DS-6 Intercom System
• IP based intercom system
• No limited modular decentralised system structure
• Intercom and PA also for Ex-areas
• Highest voice quality (12 kHz)
• 99,9999% Availability due to redundant system structure
• Fault tolerant
• Easy maintenance and configuration
• Small footprint due to compact hardware
• Interfaces to other systems such as Telephone, Radio, CCTV, F&G etc.
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 7
System Overview DS-6
System
Configuration + Service
MTSD DS-6 digital
WF AK analogue
WFA / WFA-Ex analogue
WFD / WFD-Ex digital
DS-6node
PC-call station
WFD digital free selection
DS-6 Panel mounted call station
Gate intercom analogue
Actuators Sensors Loudspeaker
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 8
DS-6 Intercom System: Networking
DS-6Node
DS-6Node
DS-6Node
Node 1 Node 2 Node n
Copper, FO, Wireless LAN
Copper, FO, Wireless LAN
Subscriber in a LAN
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 9
Digital Intercom Call Stations
PC call station Desktop call stations
Weather- / explosionproof call stations
Panel mounted call stations
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 10
Digital Outdoor Call Stations
operating voltage range:
48 V - 60 V
ambient temperature:
-25°C - + 70°C
internal amplifier:
1 Watt
potentially explosive areas:
up to zone 2 ATEX
housing:
glassfibre, reinforced
ingress protection:
IP 66
25 W loudspeaker115 dB sound pressure
level at a distance of
30 cm
microphone withelectronic noise
compensation
and dynamic
compression
potentiometer toadjust
the microphone
sensitivity
and the volume of the
internal
loudspeaker
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 11
operating voltage range:
48 V - 60 V
ambient temperature:
-20°C - +70°C
ignition protection:
Zone 1 ATEX
EEx de ib IIC T4
housing:
glassfibre, reinforced
ingress protection:
IP 66
25 W loudspeaker115 dB sound pressure
level at a distance of 30 cm
microphone withelectronic noise compensation
and dynamic compression
potentiometer to adjust
the microphone sensitivity
and the volume of the internal
loudspeaker
Digital Explosion-proof Call Stations DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 12
Digital Desktop Call Stations – MTSD DS-6
Operating voltage range: 24V - 72V
Ambient temperature: 0°C - +50°C
Internal amplifier: 1 Watt
Protection class: IP30
• IP based call station
• Ethernet connection
• Up to 112 direct dialling keys
(with two additional casings)
• Flexible goose-neck microphone
• Internal loudspeaker (1 Watt)
• LED signalling
• Illuminated LCD
• Integrated voice memory
• Self-monitoring
• High voice quality 12 kHz
• Power over Ethernet (PoE)
• Redundant interfaces
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 13
DS-6 Panel-mounted Call Station
Operating voltage range: 24V - 72V
Ambient temperature: 0°C - +50°C
Loudspeaker: 1 Watt / 8
Protection class: IP20
• IP based call station
• Ethernet connection
• 12 to 48 direct dialling keys
• LED signalling
• Noise compensated goose-neck
microphone
• Loudspeaker (1 Watt / 8 )
• All components in instrument
housing of 110 x 230 mm
• Integrated voice memory
• Monitoring
• High voice quality 12 kHz
• Power over Ethernet (PoE)
Loudspeaker
Keypad
Noise compensating
goose-neck microphone
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 14
DS-6 Panel-mounted Call Station 19’’
Operating voltage range: 24V - 72V
Ambient temperature: 0°C - +50°C
Loudspeaker: 1 Watt / 8
Protection class: IP20
• IP based call station
• Ethernet connection
• 16 illuminated destination keys
• Special alarm key with closure lid
• LED signalling
• Noise compensated goose-neck
microphone
• Loudspeaker (1 Watt / 8 )
• Illuminated LCD
• Integrated voice memory
• Self-Monitoring
• High voice quality 12 kHz
• Power over Ethernet (PoE)
Loudspeaker Keypad
Noise compensating
goose-neck microphone
Alarm key
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 15
DS-6 PC Call Station
PC Call Station • Consisting of software package
NEMMS, loudspeaker andmicrophone or headset,interface to DS-6
• ca. 4095 keys programmable
• Free creatable screen layout
• Operation via mouse or touchscreen
• Monitoring by Audio Module
Organisation Panel: * changing between different
operation panels
e.g different plant-areas
Operation Panel: * programing of the key-functions
e.g speech connections, alarms,
general calls
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 16
DS-6 PC Call Station – Example for graphical layout DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 17
DS-6 PA System: Simplest System Structure Connection of amplifiers and loudspeaker circuits
MTSD DS-6
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 12
DS-6 PA-Control
2x250W Amplifier
Switch
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 18
Connection of outdoor call stations (digital/analogue)
UK0-Adapter/ Analogue adapter
MTSD DS-6
WFD 1/ WFA 1
WFD 8/ WFA 8
WFD 2/ WFA 2
DS-6 Intercom: Simplest System Structure DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
DS-6 UK0 Adapter digital (n x 8 ports) Page 19
DS-6 Uk0 Adapter System
structure
DS-6 Master
call station
16keys
Digital Ex-poof outdoor call-stations
Telefone cable
Cat.5e cable
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 20
Driller Floor
8
Monkey Board
2
Stabbing Board
1Strobe light for
optical display
an incomming
call
(optional)
Additional
loudspeaker
(optional)
Foot switch for
hands-free
communication
(optional)
• Hands-free communication in harsh work areas
• IP based DS-6 System•
easy extension of necessary devices•
Competitive price
Master Call Station
IP DS-6 Network
JB JB
System Application: Drilling Rig Intercom System DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 21
Redundant System StructureDS-6
System
Net Node 1
FO
FO
Net Node 2
Switch
DS-6 PA Control
Switch
(redundant)
Zone 1 Zone 6
Switch
DS-6 PA Control
Switch
(redundant)
Zone 1 Zone 6
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 22
Connection of a DECT Headset System DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 23
• Handsfree unattended conversation
• Optimal voice communication in noise environments
• Connections headset control room
• Also in ATEX-Version
• Possible application areas:
Chemical industry
Glass works
Steel works
Oil platforms
…
Connection of a DECT Headset System DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 24
DS-6
System
Modem for high distances between DS-6 indoor call stations and the DS-6 node
MTSD DS-6
Switch
DS-6
19‘‘ DSL mounting modem
ETH-2W Desk Top
DSL-Modem ETH-2W
Net node
2/4-lines
5,7/11,4 Mbit/s
100m
Distance: 3 km
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 25
Amplifier 1
Analogue Adapter
Call Station 1
PA via WireLess LAN in DS-6 Systems
DS-6 Network
Switch
DS-6 Network
Switch
Amplifier 8
Ethernet Ethernet
Line of sight connection
Access Point Access Point
LC 1 = Plant Zone 1 LC 2 = Plant Zone 2
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 26
Public Address via WireLess LAN in DS-6 Systems
• IP-based DS-6 system
• Easy system structure
• Easy extension of necessary devices
• Direct connection from the access points to the DS-6 network
• No interfering cables
• Announcements from the call station to the loudspeakers via Wireless LAN
• The distance between the two access points depends on the interference
factors
• Use of multiple Access Points without interruptions possible
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 27
Crane communication via WireLess LAN in DS-6 systemsDS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 28
The New Crane Call Station
Special features:
• Integrated power supply
• Connected by WLAN Access Point
• WLAN Access point supplied by call station (PoE)
• Distances of several 100m possible
• Easy mounting with 4 quick releases
• Hands-free voice communication with external foot
switch possible
Equipment features:
• 16-part keypad
• Electret microphone + high-quality loudspeaker
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 29
Crane Communication via WireLess LAN in DS-6 Systems
• Direct connection from the access points to the DS-6 network
• No interfering cables
• Hands-free conversation on the crane with foot switch
• Panel-mounted call station on the crane
• One access point integrated in the crane call station
• The other access point at the same height for sight connection
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 30
System Monitoring – DS-6 Manager
All components are
continously monitored:
- Call stations
- Loudspeakers
- Microphones
- Voice memories
- Amplifier
- Transmission paths
- etc.
Monitoring of all
cables for:
- Short-cut
- Damaged cable
- Bad data communication
- Call station not connected
- etc.
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 31
Diagnostic Function
Digital service call station
LCD-Display --> Indication of the actual status and
error messages
Dialling keypadis used for dialling
connections to all
subscribers of the
intercom system
internal loudspeaker
max. 112 direct keys free key configuration as intercom
destination keys or for local functions are used for e.g
- general call
- communication master call station
MAIN FEATURES:
• Visual and acoustic identification
of error messages• Diagnostic of failure shown on
the display
• Self-monitoring
noise compensated
goose neck microphone
with dynamic compression
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 32
Connection to further analogue or digital
intercom systems
DS-6 MDK MF84
as well as to older or foreign
intercom systems
Telephone System
Public Address System
Configuration
& Service
Digital (analogue) Stations of the
approved NEUMANN quality
I/O Module
Connection to other systems, e. g. for
• fire alarm
• remote control
• warning and alarm
Radio SystemIP based Communication
System DS-6
System Integration
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 33
Gate intercom
DS-6 node
Loudspeaker
Panel mounted
call station
Outdoor call station free selection
Wind sensor
Flashing beacon
Alarm horn
Ventilator
Gas detector
Door opener
Thermometer
PLC
Clock
Desktop call station
Actuators
Sensors
Outdoor call station
System Integration
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 34
Cabling Structure at a Conventional Centralised System DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 35
Cable Saving due to the Decentralised System DS-6
Netnode 1 Netnode 2
Netnode 3 Netnode n
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 36
„Single point of failure“ – Single fault leads to totalsystem shut down
Central unit has a failure
Filed devices
failed
Conventional Centralised System Failure Mode
Interface to other
systems failed
Remote Sub-
systems failed
Diagnostic and
alarms failed
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 37
Decentralised System Failure Mode
Remote sub
systems and field
devices still
operational
Part of the system
has a failure
No „Single point of failure“ – System is still operational
Interfaces to other
systems are still
operational
Diagnostic is still
operational
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 38
Decentralised Redundant System Failure Mode
Part of the system
has a fault
Fault Tolerant – System is fully operational
DS-6
System
Layer-A
Layer-B
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 39
PA DS-6 PA-Control
Configurable via DS6-Network DS-6 connection with audio transmission and fault reporting
Control 4 loudspeaker zones + 2 zones
Detection of amplifier faults and switching to backup amplifier
Impedance and ground fault monitoring
Loop monitoring of two zones
Environmental noise depending volume control
Wide range supply voltage input (18V – 60V)
All PA-GA-System Functions in one Controller
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 40
PA-System with DS-6 PA-Control PA
1
Backup
Amplifier
Redundant
network 2
250W
RJ45
Patch cable
…
AB
System cable
13 14
250W 250W
DS-6 net
LZ 4 LZ 3
LZ 2 LZ 1
same wiring to 50W and 100W
Neumann amplifier with the
Backplane 22 1 5004 150 0
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 41
DS-6 – At a Glance • IP based intercom system
• Intercom and PA also for Ex-areas
• PA system according to DIN EN 60489 and DIN EN 54-16
• Short startup phase (< 10 s)
• Highest voice quality (12 kHz)
• High distances possible
• Highest safety due to redundant system structure and monitoringpossibilities
• Easy maintenance and configuration
• Low use of hardware
• Scalable system structure
• Interfaces to existing systems
DS-6
System
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 42
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 43
TIMM (Total Information ManageMent) – Integrated System Solution TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 44
Integration of Our Systems into Existing Management Systems
Overall IP transmission network Telecommunication Video surveillance
Facility management
Intercom system
PA
General alarm
Emergency call
Fire alarm system
Management system
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 45
Focus on Voice Communication with Our Technology in Standardised IP Networks
DS-6node
StandardIP network
MDKexchange
Analogueexchange
TIMMPC call station
Software:TIMM Intercom server
TIMM Telephone server
DS-6node
GSM network
ISDN network
SIP
SIP
IP telephones (Protocol: SIP)
Gateway
Gateway
GatewayGateway
Gateway
Gateway
i.a. MZV
Com server
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 46
Physical System Structure (Example) MMS
ComServer ComServer (redundant) DS-6 Gateway
L2 Switches
(unmanaged)
L2 Switch (unmanaged)
DS-6 Gateway DS-6 Gateway
L2 Switches
(unmanaged)
Analog adapter Analog adapter
DS-6 DS-6
DS-6 Management system,
workstations
„Visualization and
operating layer“ Integrated
communication
system
Redundant
transmission
network (OSPF)
Redundant
self-sufficient
sub system
„process layer“
L3 Switch
L3 Switch L3 Switch
L3 Switch
Integrated
communication
system
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 47
Reference: BP-Lingen
Application Example TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 48
Reference: BP-Lingen – IP based warning system
• 5 LANs
• High reliability due to redundancy
• 325 call stations
• 1693 loudspeakers + PA in buildings
• Size of factory premises: 536.000 m²
• According to VDE 0828 resp. EN 60849 and DIN VDE 0833-4
• Integration of existing end devices
• Migration of existing exchanges
Application Example TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 49
Application Example TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 50
Voice Communication via Satellite TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 51
Requirements:
• Connection of 5 areas in 3 countries
• High availability
• High reliability
• Redundant network transnational
• Combination from intercom and telephony
Application Example TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 52
Application Example TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 53
Requirements:
• Modern IP system via existing cable infrastructure and DSL modems
• Centralised alarm control of a complete factory
• Connection of a PLC for controlling of automatic alarms (e.g. Wago,Siemens, Beckhoff, etc.)
• Connection of existing subsystems (e.g. analogue intercom exchange)• Voice recording• PC call stations which are configurable by the customer
• Large screen for illustration and controlling of the alarm processes(Mimic display)
• Connection of a PABX
• Redundant system structure
Application Example TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 54
Connection to a SCADA System via OPC
• Typical applications for SCADA systems:
Process visualisation and controlling in power plants, oil and gas facilities
Information systems for monitoring of highways and tunnel systems
Management systems in production plants, etc.
• OPC = Standard for communication between different manufacturers
Controlling and monitoring of different manufacturers in one common
flexible network
Standardised interface for the data exchange with SCADA systems
Integration into a central management system:
Control connections
Standardised visualisation of fault and status messages
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 55
DS-6 LAN1
ComServer 1
Gateway 1
TIMM Netzwerk TCP/IP
OPC Server 1
SCADA System
IP Network
SCADA System for
DS-6/TIMM TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 56
Connection to a SCADA System via OPC TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 57
Example: Tunnel Aalsmeer – Project Description
• Twin tube road tunnel
• 37 IP phones, 3 IP emergency call pillars
• 3 operator stations:
IP phone at the management system
Softphone inside the monitor of the management system
IP service phone at the netnode cabinet
• Switching to the communication exchange Siemens HIPATH possible
• All control tasks of the emergency call system provides the
TIMM ComServer
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 58
Example: Tunnel Aalsmeer – Special Features
• High level of voice quality at the IP phones (> 0,6 STI)
• Redundant OPC interface for secure transfer of the fault messages
and illustration at the centralised management system
• Service PC with NEMMS user interface in the network cabinet
• Volume adjustment of the emergency call phones to the ambient noise
in the tunnel
• Detecting and forwarding of fault messages to the management
system as well as to the service PC
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 59
Example: Tunnel Aalsmeer – System Overview TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 60
Example: Controlling and monitoring with existing management system
Customer Network
DS-6 DS-6
SIP-Trunk
30 Channels
TIMM ComServer (redundant)
TIMM OPC Server
DS-6 DS-6
Management System
TIMM Multi Audio Server (redundant)
MMS
Workstation
TIMM DS-6 Gateway
(redundant)
PLCPLC
PC Call Station
TIMM DS-6 Gateway
(redundant)
TIMM DS-6 Gateway
(redundant)
TIMM DS-6 Gateway
(redundant)
PC Call Station
Voice over IP
System
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 61
Fault Management via SNMP with TIMM View TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 62
• Standard functions from DS-6
e.g. single calls, group/all calls, alarm functions,
dynamic group calls, voice memory etc.
• Standard functions from telephony
e.g. conferences, forwarding, parking etc.
• Combined functions from intercom and telephony
• Cross-section functions for diagnostic and maintenance
TIMM Functions TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 63
TIMM Functions • Interconnection of intercom, PA and telephony
• Equipping of telephones with additives for monitoringand evacuation
• Using a telephone like an intercom call station
(priorities, hands-free communication, …)
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 64
PA from a Phone
• Manual and automatic PA
• Speaking from a phone directly toone or more loudspeaker circuits
• Internal and external phoneconnections possible(even from mobile phone)
• Special feature:acoustic signal for connections
• Retrieving a saved text or tone andoutput to the destination
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Connection Phone – Call Station
• Connection between phone andDS-6 call station by DS-6 gateway
• Call controlling by the keys from the callstation
• Termination of the call
- by hang up the phone subscriber
- by delete key at the call station
- by request by a configured timer
TIMM
Page 65
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 66
Retrieval of Recorded Alarm Announcements from a Phone
• Recording and saving of alarm announcements in
TIMM Telephone Server
• Retrieval of the recorded alarms from a phone
• Selection of a text (alarm) via voice menu
Speech Boxes
• Recording of manual announcements at a call station
• Saving these announcements in speech boxes
• Output of the announcements at the own call station or other
defined destinations
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 67
Cross-section Functions for Diagnostic and Maintenance
• Voice recording (DS-6 Recorder, Voice boxes)
• Protocol recording:
Registering all important messages and status information
Retrieval via WEB-Server
• Connection to a network management
• Graphical fault illustration (SNMP-MIB)
• Time server connection (NTP-Server = Network Time Protocol Server)
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 68
TIMM (Total Information ManageMent) – At a glance
• Integrated safety solution with IP technology for intercom, PA,telephony, video, …
• Use of standardised IP networks
• No proprietary networks required
• Low hardware effort
• High reliability due to independent subsystems (DS-6, MDK, …)
• Easy extensions due to modular system structure
• High reliability due to redundancy
• High flexibility due to many interfaces
• Integration into existing management systems
TIMM
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH
Page 69
Communication and Information Systems in Harsh Environments
Specialisten in communicatie www.telecomsystems.nl Tel. +31 (0)10-2660111
ms NEUMANN ELEKTRONIK GmbH