Hollow Floor Combi T ThermoHeating Pipe grid 100 Pipe grid 150
HeatflowdensityqGacc.toDINEN1264-2(withoutcovering,R=0,00mK/W)
77W/m 60W/m
atstandardheatingliquidovertemperatureH 12K 12K
HeatflowdensityqGacc.toDINEN1264-2(withcovering,R=0,15mK/W)
89W/m
78W/m
atstandardheatingliquidovertemperatureH 26K 29K
R,Bcarpet 0,070,23mK/W 0,070,23mK/W
R,Bceramictile/stone 0,02mK/W 0,02mK/W
R,BPVC 0,01mK/W 0,01mK/W
Cooling
Specificcoolingcapacityacc.toDINEN1264-5
38,2W/m 28,7W/m
CoolingliquidtemperatureH 8K 8K
Heating and cooling
Anadequatetemperatureisimportantforacomfortableindoorclimateandagoodplacetowork.Afurtheradvan-tageinofficesistheinvisibleinstalla-tionofsupplylines.TheMEROhollowfloorCombiTTher-mocombinesthesetwocharacteris-tics.TheMEROCombiTThermocanbeusedinalmostallareas,whetherit
concernsnewbuildingsortherefur-bishmentofoldbuildings.Thesystemdoesnotrequireanyspecificheatingcircuitconnections.Allfloorcoveringssuitableforunderfloorheatingasstoneandceramictiles,textilefloorcover-ings,dimensionallystablefloorcover-ingsanddifferenttypesofparquetcanbeappliedonMEROCombiTThermo.
TVcertifiedsince1997
Ourco-operationpartner:
TheMEROhollowfloorCombiTThermoistestedacc.toDINEN1264-2/3/4no.7F249-Fand7F250-Fandcertifiedbyindependentinstitutes. MERO-TSK International GmbH & Co. KG
Technicaldata*: Combi T ThermoAccessories: Drillingisdoneatfactoryoronsitefor:Powersupplyandtwist-airoutletsExpansionjoints/constructionjoints/jointsRevisionopeningsAccessfloorductsCutoutsSpecialwallconnectionsFasciaBridgingAdditionalinsulation(heat,impactsound)Stairs,rampsFloorcoveringsasstone,parquetetc.
*For further detailed technical datapleaseaskforourproductdatasheets.
Bearing layer:
Dimensions: 600x600Systemweight: 56kg/mto66kg/mPanelmaterial: Calciumsulphatepanel(fiber-reinforcedcalciumsulphate)Adhesive: Highqualitysolvent-freeadhesiveforthe
adhesionofthetoothing
Substruction
Module: 600x600mmPedestalmaterial: GalvanizedsteelConstructionheight: From50mmPedestalbonding: Normallygluedwiththesubfloorandthe
panel;continuouslyadjustabletoheight
Floor coverings
Textileundelasticfloorcoverings,parquet,naturalstone,artificialstone,liquidcoating
Load values Pointload:Valuedacc.toDINEN13213:Ultimateload:
3.0005.000NClass25>6.00010.000N
Fire protection
BuildingmaterialclassbearingpanelAcc.toEN13501T1: A1Fireresistanceclassacc.toDIN4102T2: F30possible
Acoustic values
(dependingonsystemandfloorcovering)
SoundreductionindexRL,w,P 3954dBNormalizedimpactsoundpressurelevelLn,w,P 4291dBImprovementofsoundpressurelevelLw,P 1029dB
NewdenominationaccordingtoDINENNormalizedflankleveldifferenceDn,f,w,PNormalizedflankimpactsoundpressureLn,f,w,PImprovementofsoundpressurelevelLw,P
Heat flow density of the FH at pipe grid galv. = 100 mm
Hea
t flo
w d
ensi
ty q
[W/m
]
Limiting curve living zone 9K
Limiting curve perimeter area 15K stone 18 mm
Heating liquid over temperature [K]
Heat flow density of the FH at pipe grid galv. = 150 mm
Limiting curve living zone 9K
Limiting curve living zone 15K stone 18 mm
Limiting curve living zone 9K
Stone 18 mm
Limiting curve living zone 15K stone 18 mm
Heating liquid over temperature [K]
Hea
t flo
w d
ensi
ty q
[W/m
]
Cooling capacity of the FH at pipe grid galv. = 100 mm
0
5
10
15
20
25
30
35
40
0 2 4 6 8 10
Cooling liquid under temperature T [K]
Coo
ling
flow
den
sity
q [W
/m2 ]
0,000
0,050
0,100
0,150
Stone 18 mm
Nominal cooling capacity at 8K
Coo
ling
flow
den
sity
q [W
/m2 ]
Cooling capacity of the FH at pipe grid galv. = 150 mm
0
5
10
15
20
25
30
35
40
0 2 4 6 8 10
0,000
0,050
0,100
0,150
Stone18 mm
Nominal cooling capacity 8 K
Cooling liquid under temperature T [K]
Headoffice:
MERO-TSKInternational GmbH & Co. KG
Max-Mengeringhausen-Str.5
97084Wrzburg,Germany
Postaladress:
MERO-TSKInternational GmbH & Co. KG
ProductDivisionFloorSystems
LauberStrae11
97357Prichsenstadt,Germany
Phone.:+49(0)9383203-603
Fax:+49(0)9383203-629
E-mail:[email protected]
Internet:www.mero.de
-
Foreconomicandecologicalreasons,roomstodayaremoreandmoreheatedandcooledbyactivatedspaces.Thelargertheheatedpartofthespace,thelowertheenergyrequired.Thisredu-cesthecostofheatingandcooling.TheMEROCombiTThermoisadryhollowfloorwithafloorheatingandcoolingsystem.
Fields of application
TheMEROCombiTThermocanbeusedinalmostallareas,whetheritconcernsnewbuildingsortherefur-bishmentofoldbuildings.Inprinci-ple,allfloorcoveringssuitableforfloorheatingcanbeinstalledonMEROCombiTThermo:
stoneandceramictiles
textilefloorcoverings
dimensionallystableelasticfloorcoverings
differenttypesofparquet
Advantages
Especially suitable for low tem-perature plants according to EnEV
Extremelyshortconstructiontime
MaximumsystemsafetyduetotightnesstestaccordingtoDINUponorPE-Xatube
CombiTThermoisprovedashea-tingandcoolingsystemacc.toDINandcertifiedacc.toDINCertco
Variousgridsandvariableconstructionheightsarepossible
Verygoodstructural-physicalcha-racteristics
Favourablecooling,especiallywithgroundwaterheatpumps
Healthyindoorclimatethroughra-diantheat
TheMEROdryhollowfloorwithpre-fabricatedgroovesfortheheatingpipesisinstalledaccordingtothelayoutdrawing.
Theplasticpipeisplacedintothegrooves.
Thecutoutsareprefabricated(e.g.forelectricunderfloortankswhicharein-stalledonsite)
Priortothegroutingofthebodyfiller,allpipesaretestedforleaks.
Theprotrudingbodyfillerwillbere-movedfromthesupportingpanel.
AftertheoperationalheatingtheMEROCombiTThermoisreadyfortheappli-cationofthefloorcovering.
System floor
Planning instructions
Theplanningandsettingofthehea-tingandcoolingcircuitsiscarriedouttogetherwiththeTGAplanner.Onrequest,thecalculationofthepipenetworkcanbedonebyMERO.TheMEROCombiTThermocanalsobeoperatedalongthemethodofTi-chelmann.Withafewstandardpa-nelswemeetallstructuralrequire-ments.
Construction principle
Thesupportingpanelsconsistofin-combustiblefiber-reinforcedcalciumsulphate,whichguaranteeanopti-malheattransmission.Specialmilledgroovesfortheinstallationandfix-ingofthepipeworkintegratethefloorheatingintothefloorpanel.Aftertheinstallationoftheheatingpipe,thegroovesarefilledwithbodyfillerflushwiththesurface.Thermallyinsulatedconnectingpipesensureanoptimalenergysupply.Duetothedewpointcontroltheac-cumulationofcondensedwatercanbeavoided.
5
2
1
54
31.Supportingpanelwith groovesfortheheatingpipes2.Heatingpipe3.Bodyfiller4.Pedestal5.Perimeterstrip
Weuseplasticpipesconsistingofhigh-lycross-linkedpolyethylene.Thepipestructurehasanoxygenbarrierwhichexceedsbyfarthestandardrequire-mentsregardingoxygentightness.Thesubstructureconsistsofsteelpedes-tals.Theirheightcanbeexactlyadjus-ted.Allpedestalsareprotectedagainstcorrosionbygalvanizationandpassiva-tion.Thepedestalbaseplatesaregluedtotherawsubfloor.Dependingontherequirements,variouspaneltypesareavailable.
Construction process
2MERO-TSK International GmbH & Co. KG
4MERO-TSK International GmbH & Co. KG
-
Foreconomicandecologicalreasons,roomstodayaremoreandmoreheatedandcooledbyactivatedspaces.Thelargertheheatedpartofthespace,thelowertheenergyrequired.Thisredu-cesthecostofheatingandcooling.TheMEROCombiTThermoisadryhollowfloorwithafloorheatingandcoolingsystem.
Fields of application
TheMEROCombiTThermocanbeusedinalmostallareas,whetheritconcernsnewbuildingsortherefur-bishmentofoldbuildings.Inprinci-ple,allfloorcoveringssuitableforfloorheatingcanbeinstalledonMEROCombiTThermo:
stoneandceramictiles
textilefloorcoverings
dimensionallystableelasticfloorcoverings
differenttypesofparquet
Advantages
Especially suitable for low tem-perature plants according to EnEV
Extremelyshortconstructiontime
MaximumsystemsafetyduetotightnesstestaccordingtoDINUponorPE-Xatube
CombiTThermoisprovedashea-tingandcoolingsystemacc.toDINandcertifiedacc.toDINCertco
Variousgridsandvariableconstructionheightsarepossible
Verygoodstructural-physicalcha-racteristics
Favourablecooling,especiallywithgroundwaterheatpumps
Healthyindoorclimatethroughra-diantheat
TheMEROdryhollowfloorwithpre-fabricatedgroovesfortheheatingpipesisinstalledaccordingtothelayoutdrawing.
Theplasticpipeisplacedintothegrooves.
Thecutoutsareprefabricated(e.g.forelectricunderfloortankswhicharein-stalledonsite)
Priortothegroutingofthebodyfiller,allpipesaretestedforleaks.
Theprotrudingbodyfillerwillbere-movedfromthesupportingpanel.
AftertheoperationalheatingtheMEROCombiTThermoisreadyfortheappli-cationofthefloorcovering.
System floor
Planning instructions
Theplanningandsettingofthehea-tingandcoolingcircuitsiscarriedouttogetherwiththeTGAplanner.Onrequest,thecalculationofthepipenetworkcanbedonebyMERO.TheMEROCombiTThermocanalsobeoperatedalongthemethodofTi-chelmann.Withafewstandardpa-nelswemeetallstructuralrequire-ments.
Construction principle
Thesupportingpanelsconsistofin-combustiblefiber-reinforcedcalciumsulphate,whichguaranteeanopti-malheattransmission.Specialmilledgroovesfortheinstallationandfix-ingofthepipeworkintegratethefloorheatingintothefloorpanel.Aftertheinstallationoftheheatingpipe,thegroovesarefilledwithbodyfillerflushwiththesurface.Thermallyinsulatedconnectingpipesensureanoptimalenergysupply.Duetothedewpointcontroltheac-cumulationofcondensedwatercanbeavoided.
5
2
1
54
31.Supportingpanelwith groovesfortheheatingpipes2.Heatingpipe3.Bodyfiller4.Pedestal5.Perimeterstrip
Weuseplasticpipesconsistingofhigh-lycross-linkedpolyethylene.Thepipestructurehasanoxygenbarrierwhichexceedsbyfarthestandardrequire-mentsregardingoxygentightness.Thesubstructureconsistsofsteelpedes-tals.Theirheightcanbeexactlyadjus-ted.Allpedestalsareprotectedagainstcorrosionbygalvanizationandpassiva-tion.Thepedestalbaseplatesaregluedtotherawsubfloor.Dependingontherequirements,variouspaneltypesareavailable.
Construction process
2MERO-TSK International GmbH & Co. KG
4MERO-TSK International GmbH & Co. KG
-
Foreconomicandecologicalreasons,roomstodayaremoreandmoreheatedandcooledbyactivatedspaces.Thelargertheheatedpartofthespace,thelowertheenergyrequired.Thisredu-cesthecostofheatingandcooling.TheMEROCombiTThermoisadryhollowfloorwithafloorheatingandcoolingsystem.
Fields of application
TheMEROCombiTThermocanbeusedinalmostallareas,whetheritconcernsnewbuildingsortherefur-bishmentofoldbuildings.Inprinci-ple,allfloorcoveringssuitableforfloorheatingcanbeinstalledonMEROCombiTThermo:
stoneandceramictiles
textilefloorcoverings
dimensionallystableelasticfloorcoverings
differenttypesofparquet
Advantages
Especially suitable for low tem-perature plants according to EnEV
Extremelyshortconstructiontime
MaximumsystemsafetyduetotightnesstestaccordingtoDINUponorPE-Xatube
CombiTThermoisprovedashea-tingandcoolingsystemacc.toDINandcertifiedacc.toDINCertco
Variousgridsandvariableconstructionheightsarepossible
Verygoodstructural-physicalcha-racteristics
Favourablecooling,especiallywithgroundwaterheatpumps
Healthyindoorclimatethroughra-diantheat
TheMEROdryhollowfloorwithpre-fabricatedgroovesfortheheatingpipesisinstalledaccordingtothelayoutdrawing.
Theplasticpipeisplacedintothegrooves.
Thecutoutsareprefabricated(e.g.forelectricunderfloortankswhicharein-stalledonsite)
Priortothegroutingofthebodyfiller,allpipesaretestedforleaks.
Theprotrudingbodyfillerwillbere-movedfromthesupportingpanel.
AftertheoperationalheatingtheMEROCombiTThermoisreadyfortheappli-cationofthefloorcovering.
System floor
Planning instructions
Theplanningandsettingofthehea-tingandcoolingcircuitsiscarriedouttogetherwiththeTGAplanner.Onrequest,thecalculationofthepipenetworkcanbedonebyMERO.TheMEROCombiTThermocanalsobeoperatedalongthemethodofTi-chelmann.Withafewstandardpa-nelswemeetallstructuralrequire-ments.
Construction principle
Thesupportingpanelsconsistofin-combustiblefiber-reinforcedcalciumsulphate,whichguaranteeanopti-malheattransmission.Specialmilledgroovesfortheinstallationandfix-ingofthepipeworkintegratethefloorheatingintothefloorpanel.Aftertheinstallationoftheheatingpipe,thegroovesarefilledwithbodyfillerflushwiththesurface.Thermallyinsulatedconnectingpipesensureanoptimalenergysupply.Duetothedewpointcontroltheac-cumulationofcondensedwatercanbeavoided.
5
2
1
54
31.Supportingpanelwith groovesfortheheatingpipes2.Heatingpipe3.Bodyfiller4.Pedestal5.Perimeterstrip
Weuseplasticpipesconsistingofhigh-lycross-linkedpolyethylene.Thepipestructurehasanoxygenbarrierwhichexceedsbyfarthestandardrequire-mentsregardingoxygentightness.Thesubstructureconsistsofsteelpedes-tals.Theirheightcanbeexactlyadjus-ted.Allpedestalsareprotectedagainstcorrosionbygalvanizationandpassiva-tion.Thepedestalbaseplatesaregluedtotherawsubfloor.Dependingontherequirements,variouspaneltypesareavailable.
Construction process
2MERO-TSK International GmbH & Co. KG
4MERO-TSK International GmbH & Co. KG
-
Floor Systems
MERO Hollow Floor Combi T ThermoInnovative solutions from one source
Development
Consulting
Planning
Manufacturing
Installation
AccessFloor
HollowFloor
Floorcoveringand
Installation
Services
EnEV-prov
ed
06.13/C
ombiTThe
rmo
Subjecttotech
nicalcha
ngesw
ithou
tprio
rnotice
Hollow Floor Combi T ThermoHeating Pipe grid 100 Pipe grid 150
HeatflowdensityqGacc.toDINEN1264-2(withoutcovering,R=0,00mK/W)
77W/m 60W/m
atstandardheatingliquidovertemperatureH 12K 12K
HeatflowdensityqGacc.toDINEN1264-2(withcovering,R=0,15mK/W)
89W/m
78W/m
atstandardheatingliquidovertemperatureH 26K 29K
R,Bcarpet 0,070,23mK/W 0,070,23mK/W
R,Bceramictile/stone 0,02mK/W 0,02mK/W
R,BPVC 0,01mK/W 0,01mK/W
Cooling
Specificcoolingcapacityacc.toDINEN1264-5
38,2W/m 28,7W/m
CoolingliquidtemperatureH 8K 8K
Heating and cooling
Anadequatetemperatureisimportantforacomfortableindoorclimateandagoodplacetowork.Afurtheradvan-tageinofficesistheinvisibleinstalla-tionofsupplylines.TheMEROhollowfloorCombiTTher-mocombinesthesetwocharacteris-tics.TheMEROCombiTThermocanbeusedinalmostallareas,whetherit
concernsnewbuildingsortherefur-bishmentofoldbuildings.Thesystemdoesnotrequireanyspecificheatingcircuitconnections.Allfloorcoveringssuitableforunderfloorheatingasstoneandceramictiles,textilefloorcover-ings,dimensionallystablefloorcover-ingsanddifferenttypesofparquetcanbeappliedonMEROCombiTThermo.
TVcertifiedsince1997
Ourco-operationpartner:
TheMEROhollowfloorCombiTThermoistestedacc.toDINEN1264-2/3/4no.7F249-Fand7F250-Fandcertifiedbyindependentinstitutes. MERO-TSK International GmbH & Co. KG
Technicaldata*: Combi T ThermoAccessories: Drillingisdoneatfactoryoronsitefor:Powersupplyandtwist-airoutletsExpansionjoints/constructionjoints/jointsRevisionopeningsAccessfloorductsCutoutsSpecialwallconnectionsFasciaBridgingAdditionalinsulation(heat,impactsound)Stairs,rampsFloorcoveringsasstone,parquetetc.
*For further detailed technical datapleaseaskforourproductdatasheets.
Bearing layer:
Dimensions: 600x600Systemweight: 56kg/mto66kg/mPanelmaterial: Calciumsulphatepanel(fiber-reinforcedcalciumsulphate)Adhesive: Highqualitysolvent-freeadhesiveforthe
adhesionofthetoothing
Substruction
Module: 600x600mmPedestalmaterial: GalvanizedsteelConstructionheight: From50mmPedestalbonding: Normallygluedwiththesubfloorandthe
panel;continuouslyadjustabletoheight
Floor coverings
Textileundelasticfloorcoverings,parquet,naturalstone,artificialstone,liquidcoating
Load values Pointload:Valuedacc.toDINEN13213:Ultimateload:
3.0005.000NClass25>6.00010.000N
Fire protection
BuildingmaterialclassbearingpanelAcc.toEN13501T1: A1Fireresistanceclassacc.toDIN4102T2: F30possible
Acoustic values
(dependingonsystemandfloorcovering)
SoundreductionindexRL,w,P 3954dBNormalizedimpactsoundpressurelevelLn,w,P 4291dBImprovementofsoundpressurelevelLw,P 1029dB
NewdenominationaccordingtoDINENNormalizedflankleveldifferenceDn,f,w,PNormalizedflankimpactsoundpressureLn,f,w,PImprovementofsoundpressurelevelLw,P
Heat flow density of the FH at pipe grid galv. = 100 mm
Hea
t flo
w d
ensi
ty q
[W/m
]
Limiting curve living zone 9K
Limiting curve perimeter area 15K stone 18 mm
Heating liquid over temperature [K]
Heat flow density of the FH at pipe grid galv. = 150 mm
Limiting curve living zone 9K
Limiting curve living zone 15K stone 18 mm
Limiting curve living zone 9K
Stone 18 mm
Limiting curve living zone 15K stone 18 mm
Heating liquid over temperature [K]
Hea
t flo
w d
ensi
ty q
[W/m
]
Cooling capacity of the FH at pipe grid galv. = 100 mm
0
5
10
15
20
25
30
35
40
0 2 4 6 8 10
Cooling liquid under temperature T [K]
Coo
ling
flow
den
sity
q [W
/m2 ]
0,000
0,050
0,100
0,150
Stone 18 mm
Nominal cooling capacity at 8K
Coo
ling
flow
den
sity
q [W
/m2 ]
Cooling capacity of the FH at pipe grid galv. = 150 mm
0
5
10
15
20
25
30
35
40
0 2 4 6 8 10
0,000
0,050
0,100
0,150
Stone18 mm
Nominal cooling capacity 8 K
Cooling liquid under temperature T [K]
Headoffice:
MERO-TSKInternational GmbH & Co. KG
Max-Mengeringhausen-Str.5
97084Wrzburg,Germany
Postaladress:
MERO-TSKInternational GmbH & Co. KG
ProductDivisionFloorSystems
LauberStrae11
97357Prichsenstadt,Germany
Phone.:+49(0)9383203-603
Fax:+49(0)9383203-629
E-mail:[email protected]
Internet:www.mero.de
-
Floor Systems
MERO Hollow Floor Combi T ThermoInnovative solutions from one source
Development
Consulting
Planning
Manufacturing
Installation
AccessFloor
HollowFloor
Floorcoveringand
Installation
Services
EnEV-prov
ed
06.13/C
ombiTThe
rmo
Subjecttotech
nicalcha
ngesw
ithou
tprio
rnotice
Hollow Floor Combi T ThermoHeating Pipe grid 100 Pipe grid 150
HeatflowdensityqGacc.toDINEN1264-2(withoutcovering,R=0,00mK/W)
77W/m 60W/m
atstandardheatingliquidovertemperatureH 12K 12K
HeatflowdensityqGacc.toDINEN1264-2(withcovering,R=0,15mK/W)
89W/m
78W/m
atstandardheatingliquidovertemperatureH 26K 29K
R,Bcarpet 0,070,23mK/W 0,070,23mK/W
R,Bceramictile/stone 0,02mK/W 0,02mK/W
R,BPVC 0,01mK/W 0,01mK/W
Cooling
Specificcoolingcapacityacc.toDINEN1264-5
38,2W/m 28,7W/m
CoolingliquidtemperatureH 8K 8K
Heating and cooling
Anadequatetemperatureisimportantforacomfortableindoorclimateandagoodplacetowork.Afurtheradvan-tageinofficesistheinvisibleinstalla-tionofsupplylines.TheMEROhollowfloorCombiTTher-mocombinesthesetwocharacteris-tics.TheMEROCombiTThermocanbeusedinalmostallareas,whetherit
concernsnewbuildingsortherefur-bishmentofoldbuildings.Thesystemdoesnotrequireanyspecificheatingcircuitconnections.Allfloorcoveringssuitableforunderfloorheatingasstoneandceramictiles,textilefloorcover-ings,dimensionallystablefloorcover-ingsanddifferenttypesofparquetcanbeappliedonMEROCombiTThermo.
TVcertifiedsince1997
Ourco-operationpartner:
TheMEROhollowfloorCombiTThermoistestedacc.toDINEN1264-2/3/4no.7F249-Fand7F250-Fandcertifiedbyindependentinstitutes. MERO-TSK International GmbH & Co. KG
Technicaldata*: Combi T ThermoAccessories: Drillingisdoneatfactoryoronsitefor:Powersupplyandtwist-airoutletsExpansionjoints/constructionjoints/jointsRevisionopeningsAccessfloorductsCutoutsSpecialwallconnectionsFasciaBridgingAdditionalinsulation(heat,impactsound)Stairs,rampsFloorcoveringsasstone,parquetetc.
*For further detailed technical datapleaseaskforourproductdatasheets.
Bearing layer:
Dimensions: 600x600Systemweight: 56kg/mto66kg/mPanelmaterial: Calciumsulphatepanel(fiber-reinforcedcalciumsulphate)Adhesive: Highqualitysolvent-freeadhesiveforthe
adhesionofthetoothing
Substruction
Module: 600x600mmPedestalmaterial: GalvanizedsteelConstructionheight: From50mmPedestalbonding: Normallygluedwiththesubfloorandthe
panel;continuouslyadjustabletoheight
Floor coverings
Textileundelasticfloorcoverings,parquet,naturalstone,artificialstone,liquidcoating
Load values Pointload:Valuedacc.toDINEN13213:Ultimateload:
3.0005.000NClass25>6.00010.000N
Fire protection
BuildingmaterialclassbearingpanelAcc.toEN13501T1: A1Fireresistanceclassacc.toDIN4102T2: F30possible
Acoustic values
(dependingonsystemandfloorcovering)
SoundreductionindexRL,w,P 3954dBNormalizedimpactsoundpressurelevelLn,w,P 4291dBImprovementofsoundpressurelevelLw,P 1029dB
NewdenominationaccordingtoDINENNormalizedflankleveldifferenceDn,f,w,PNormalizedflankimpactsoundpressureLn,f,w,PImprovementofsoundpressurelevelLw,P
Heat flow density of the FH at pipe grid galv. = 100 mm
Hea
t flo
w d
ensi
ty q
[W/m
]
Limiting curve living zone 9K
Limiting curve perimeter area 15K stone 18 mm
Heating liquid over temperature [K]
Heat flow density of the FH at pipe grid galv. = 150 mm
Limiting curve living zone 9K
Limiting curve living zone 15K stone 18 mm
Limiting curve living zone 9K
Stone 18 mm
Limiting curve living zone 15K stone 18 mm
Heating liquid over temperature [K]
Hea
t flo
w d
ensi
ty q
[W/m
]
Cooling capacity of the FH at pipe grid galv. = 100 mm
0
5
10
15
20
25
30
35
40
0 2 4 6 8 10
Cooling liquid under temperature T [K]
Coo
ling
flow
den
sity
q [W
/m2 ]
0,000
0,050
0,100
0,150
Stone 18 mm
Nominal cooling capacity at 8K
Coo
ling
flow
den
sity
q [W
/m2 ]
Cooling capacity of the FH at pipe grid galv. = 150 mm
0
5
10
15
20
25
30
35
40
0 2 4 6 8 10
0,000
0,050
0,100
0,150
Stone18 mm
Nominal cooling capacity 8 K
Cooling liquid under temperature T [K]
Headoffice:
MERO-TSKInternational GmbH & Co. KG
Max-Mengeringhausen-Str.5
97084Wrzburg,Germany
Postaladress:
MERO-TSKInternational GmbH & Co. KG
ProductDivisionFloorSystems
LauberStrae11
97357Prichsenstadt,Germany
Phone.:+49(0)9383203-603
Fax:+49(0)9383203-629
E-mail:[email protected]
Internet:www.mero.de