comandos mml reunion corto
TRANSCRIPT
NOKIA BSC COMMANDS
1. ZEEI ; - used to show the status of all sites in BSC2. ZEEI :BCF=(bcf no); - used to check status of particular BCF3. ZEOL:(BCF NO); - used to check alarm of particular Site.4. ZQSI ; - used to check status of X.25 link5. ZNEL; - to check status of all TCSM.
6. ZEFS:(bcf no):L/U; - used to lock/unlock BCF.7. ZEQS:BTS=(BTS no):L/U; - used to lock and unlock sector.8. ZERS:BTS=(BTS no):TRX=(TRx no):L/U; Used to lock/unlock individual TRx9. ZEFR:BCF NUM:OMU/SITE; OMU/SITE RESET10. ZAHO:ET,(ET.no) ; - To check alarm on ET. 30,3711. ZUSC:ET,E.no:BL/WO; - Used for making ET block and working. 12. ZDTF:TCSM,E.no ; - State checking of ET.13. ZEEL; -To see no. of calls continuing in a BSC
14. ZAHO; -To see all BSC related alarm37. ZAHP:::yyyy-mm-dd; -To know the alarm history of BSC
21. ZIGO; - To know the MML application done with BSC since the last two remote session
15. ZEOL:(BCF no); -To see all alarm related to one BCF16. ZEOH:::BCF=BCF num; To see alarm history of a site17. ZEOL::NR=7706; -To see all sites having OMU blocked18. ZEOL::NR=7704; -To see all sites having PCM blocked19. ZEOL::NR=7705; -To see all sites having LAPD failure20. ZEOL::NR=7411; -To see all sites on battery21. ZQUS(Enter twice):BCF=(BCF no):TRE=1:2;7(Enter)1(Enter)200(Enter) - To
know the receiving power of a PDH link :ODU:22. ZEEL:BCF(Enter)Select Option; -To know the blocked
BCF/BTS/TRx category ZEEL:BL-USR:BCF= ;
25. ZYMO:ET,E.no ; - to check slips on ET23. ZYEF:ET,(ET no); - Checking loop in ET24. ZEOH:yy-mm-dd:hh-mm-ss:bcf=(bcf no); - Alarm related to particular date and
time26. ZZZZ; - to terminate a remote session 27. ZDSB:::PCM=(ET no); - To find BCF no from a ET no/ Shows D channel
details 28. ZDTI:::PCM=(ET num); -To find D channel details29. ZEOH::NR=7767; -To see the alarm num history in BSC for the last 00.00.00
hours 30. ZEOL::NR=7767; -To find out the sectors down in one BSC
31. ZQSC(ENTER) QSC:0(ENTER) QSC:0,UNL;(ENTER) Command to change physical address ZQSC(ENTER) QSC:1(ENTER) QSC:1,UNL;(ENTER)
32. ZQLG(ENTER) QLG:0(ENTER) QLG:0;X2(ENTER) QLG:0:X25:UNL;(ENTER) Command to change linkage ZQLG(ENTER) QLG:1(ENTER) QLG:1;X2(ENTER) QLG:1:X25:UNL;(ENTER)
Comment- If the X.25 link of BSC is locked from remote end the this command is used to unlock the X.25 link from local BSC end. Then both the command (28,29) should be executed
33. ZDSB:::PCM=(ET NO); To know wheather a ET is in use or not in use34. ZWUP:ET NUM; - To know a ET type(TCSM/Abis) 35. ZQNI; -To know the numerical ID of a BSC 36. ZQRI:OMU; -To know the local IP allotted to BSC38. ZERO:BCF=(BCF NUM); -To know the TSC value for each trx39. ZQWL:BCF=76; TO know the Q1 address of FIU s present in a
site40. ZEFO:BCF ID:IOP; To know the alarm configuration in a bts site41. ZEFX:BCF NUM:INBR=alarm number:POL=OPEN/CLOSE; To change
polarity of an external alarm42. ZEFE: -External Alarm text modification command43. ZDTC: D-channel name: BL/ WO; To change the state of D-channel 44. ZERC: Trx creation45. ZERD: Trx Deletion (trx should be locked before deletion)
46. ZDSE: Lap-D creation
///////////////////////////////////////////////////////////////////////////////////////////////////
1 open0 close
ZEFX:361:INBR=15:POL=CLOSED,ROU=ACT,:SEV=AL2,TID=15,:; (bcf) posicionPolaridadNORMAMENTE CERRADA NUM AL
///////////////////////////////////////////////////////////////////////////////////////////////////////////////
Nokia Command List
NOKIA COMMANDS:
Hot Keys:
Ctrl + B repeats last and previous commands on the MML
Ctrl + Y interrupts current command being typed or run
Alarm monitoring:
ZAHO; displays current active alarms in actual MSC and BSC only
ZEOL:#; displays active alarms on BCF (BCF = Site Manager or CF)
ZEEI:BCF=#; displays the operational state of the site
ZEOH:date,time:BCF=#; displays alarm history for site for the date and time listed
ZAHO:ET,#; displays current alarms for that ET (PCM)
ZAHP:ET,#; displays alarm history for that ET
ZEEL:BL; displays locked Sites, Sectors and TRXs on BSC
/////////////Zefo:#BCF:IOP; Muestra alarmas configuradas////////
Investigating Clear Codes:
ZTUT:CLR; displays current clear codes on the MSC
ZTUL:CLR; displays latest history of clear codes
Canceling Bogus alarms on a Site: (Perform both commands)
ZEOR:#:alarm #; cancels alarm on site
ZEFR:#:OMU; resets the OMU (Operations and Maintenance Unit)
Canceling Bogus alarms on a BSC:
ZACC:####; cancels the alarm using the consecutive # in which it came in
ZACA:####; cancels the alarm using the alarm identifier #
Locking and unlocking a Site:
ZEFS:bcf #:L; locks entire Site without Forced Handover
ZEFS:bcf #:U; unlocks entire Site
Locking and unlocking Sectors:
ZEQS:BTS=#:L; locks entire sector down without Forced Handover
ZEQS:BTS=#:L:FHO,#; shuts down entire sector with Forced Handover
ZEQS:BTS=#:U; unlocks entire sector
Locking and unlocking TRXs:
ZERS:BTS=#,TRX=#:L; locks TRX down without Forced Handover (bts es en zeei, ejemplo 1237 en bcf pero en zeeil es 1238)
ZERS:BTS=#,TRX=#:L:FHO,#; shuts down TRX with Forced Handover
ZERS: BTS=#,TRX=#:U; unlocks TRX
Resetting the Site or OMU:
ZEFR:#:SITE; restarts SITE (PARA RESETEAR SITIO EN GSM)
ZEFR:#:OMU; restarts OMU
Bouncing Lap D’s on a Site:
ZDTI:::PCM=#; displays Lap D channels for entire site
ZDTC:lap d #:BL; blocks desired Lap D channel
ZDTC:lap d #:WO; places Lap D channel in working state
Error Checking on an ET (PCM):
ZYMO:ET,#; checks error counter for specific ET
ZYEU:ET,#:SLIDL=5; resets error counter for specific ET
Querying the # of calls on a site:
ZERO:BTS=#; displays all calls on desired sector
ZERO:BTS=#,TRX=#; displays all calls on desired TRX only
Sparing or Rolling a BCSU:
ZUSI:BCSU; displays what BCSU the SP was previously on
ZFWO:BCSU=0&&8; displays what BCSU the BL condition is on
ZUSC:BCSU,#:SP; spares the BCSU with the BL condition on it
Y for Yes executes the command
Statusing Timeslots:
ZEEL::BCF=#; Status the timeslots on a BCF
Status ET alarms on a BSC
ZAHP:ET,:::; Show all ET's that are in alarm
Taking an ET out of Seperated State
ZUSC:ET,#:SE; Will place the ET in a Separated - No Hardware state
(SE-NH)
Status session for User ID and commands:
ZIGO: Displays commands run for BSC on specific date and time.
Reloading software on a site:
ZEWV:BCF #:BU; Reloads the software on a BCF
Checking OMC alarms:
Open a terminal and telnet to the IP
Log in
Run the following command: df –k
Taking an ET out of BL state:
ZUSC:ET,#:
WORKING
BLOCKED
TEST
SEPERATED
SEPERATED-NO HARDWARE
Go back up the tree to get it back into Working
Rolling the BCCH on a Sector:
ZDTI:::PCM=#; Find out what TSL the radio is on that you want the BCCH on
ZDTC:lapd:BL; Block the TSL on the radio that the BCCH is going to
ZDTC:lapd:AL; Allow activation of the TSL that the BCCH is going to
ZDTC:lapd:WO; Brings TSL to a working state that the BCCH is going to
ZDTI:::PCM=#; Find out what TSL the radio that HAD the BCCH is on
ZDTC:lapd:AD; Deny Activation of the TSL that HAD the BCCH on it
ZDTC:lapd:BL; Block the TSL that the BCCH was on
ZDTC:lapd:WO; Brings the TSL to a working state
Clearing Circuit Releasing Failed in CAS alarms:
The alarm that you are talking about happens on MF circuits and is caused by the LEC not releasing or acknowledging us quick enough. Do to the latency, the Nokia locks out the trunk in question. When you see this alarm you should assume that it is 911 related and the issue needs to be corrected ASAP. The alarm field will be shown below.
<HIST> SLMSC001 CASU-1 SWITCH 2005-11-27 00:07:37.44
*** ALARM CASU-1 1E001-00 SI9_SO
(9952) 2153 CIRCUIT RELEASING FAILED IN CAS
1081d 13d 29 0823 01 FF 01 02 01 01 10 00 00 00
If you look above I have highlighted in red the circuit that needs to be reset (1081-13). If you take the circuit to a NU state for about 30 seconds and then back to WO it should clear.
ZCEC:CRCT=1081-1:BA;
ZCEC:CRCT=1081-1:NU;
ZCEC:CRCT=1081-1:BA;
ZCEC:CRCT=1081-1:WO;
Also, you should get a Low Traffic Capacity alarm with supplementary information. I have the alarm listed below and the supplementary info is in red (02 0386). If you convert 386 from HEX to Decimal it comes out to 902. At that time you can do the command ZRCI:SEA=3:CGR=902:PRINT=5:; and look at the circuit group.
<HIST> SLMSC001 CM-1 SWITCH 2005-11-29 08:07:22.06
CANCEL CM-1 1A003-03 KICKER
(0178) 2087 LOW TRAFFIC CAPACITY ON CIRCUIT GROUP
02 0386
//////////////////////////////////////////////////////////////////////////
PARA ARMAR UN COMANDO SE UTILIZA EL SISTEMA ARBOL
Z Z? A A? H H? O O?
EJEMPLOS:
ZAHO: ; Para mirar alarmas actuales.
ZAHP: ; Histórico de alarmas.
ZEEI: ; Para mirar estado y que ET está relacionada con la BCF.
ZOLT: ; Carga de señalizadores de la BSC.
***** PASSWORD *****
ZIAG; Para cambiar password.
***** ALARMAS *****
ZAHO:ET,# et; Da las alarmas activas del ET. Se pueden ver las alarmas de otros dispositivos.
ZAHP:ET,# et::AAAA-MM-DD; Lista el historial de alarmas del ET desde una fecha determinada.
ZEFO; Muestra las alarmas creadas en la BSC.
ZEFP; Muestra los textos de alarmas creadas en la BSC.
ZEEF:TID=(posición del texto):TEXT=”texto”; Crea texto de alarma en la BSC.
ZEFO:# bcf:IOP; Muestra las alarmas creadas en la BCF.
ZEFX:#bcf:INBR=(posición):POL=OPEN/CLOSED,ROU=ACT,:SEV=AL1/2/3,TID=#referente al texto creado en la bsc,:; Crea alarma en la BCF.
ZEFX:#bcf:INBR=#alarma::TID=0 Borra alarma en la BCF
ZEOL:#bcf; Muestra las alarmas activas (presentes) en la BCF.
ZEOH:AAAA-MM-DD,:BCF=# bcf; Muestra el historial de alarmas de la BCF desde una fecha determinada.
ZEOR:#bcf:#alarma; Resetea alarma.
ZEOU:XX; Habilita puerto de alarma.
ZEOB:XX; Bloquea puerto de alarma.
***** ET *****
ZUSI:ET,# et; Indica el estado administrativo del ET, puede estar BL o WO.
ZYEF:ET,# et; Indica el estado de operación del ET.
ZYMO:ET,# et; Muestra las estadísticas del ET.
ZUSC:ET,# et:TE; Permite hacer un test al ET, además es posible cambiar el estado administrativo.
ZUSU:ET,# et; Reinicia el ET.
ZAHP :ET,#et ::2008-03-25 ; Muestra historial de alarmas del ET.
ZAHO :ET,#et ; Muestra las alarmas activas en la ET.
ZAHP ::CLS=AL2 :2008-03-29 ; Muestra historial alarmas AL2.
CLS =AL3 *** alarms (require IMMEDIATE action)CLS = AL2 ** alarms (require action during the working
day)CLS = AL1 * alarms (do not require any action)CLS = DST disturbances (do not require any action)CLS = NTC notices (do not require any action)
***** PCM *****
ZDSB:::PCM=# pcm; Muestra el estado de trabajo del PCM. Indica el número del sitio (BCF) al que esta conectado el ET/PCM. Aparece por ejemplo B0153, el 153 es el numero del sitio.
ZYEF:ET,# pcm:; Indica estado del PCM.
ZDTI :::PCM=#pcm :; Estado del PCM.
ZRCI:SEA=4:CRCT=680 -0&&-31; Permite observar los circuitos del PCM 680 (desde el 0 al 31) y el nombre y numero del grupo troncal al que pertenece.
ZMCJ: PCM 431-31: se ven que slots tienen llamadas en curso.
ZCEC: CRT-431-31:BL; Bloque time slot 31 del pcm 431
ZRCI:SEA=3:GRC=571:PRINT=5; Muestra los PCM que pertenecen al grupo troncal 571.
ZNSI:NA0,3FDE; Da la pareja de links que estan asociados al Signlling Link Point 3FDE. Este codigo lo da la alarma Link Set Unavailable. Ej. 448 y 449.
ZNLI:448 & 449; Indica el estado de los Signalling Link 448 y 449. Dice tambien con que sitio estan conectados estos enlaces Ej, BSPA3 (BSC Parque 3).
ZDTI:NAME=B0120; Da el estado del canal D-channel B0120. Este nombre puede obtenerse utilizando el comando ZEEI.
ZDTC:B0181:WO; Sirve para activar o desactivar el canal D-channel con nombre B0181.
ZEFR:(BCF):OMU:; Resetea el OMU.
ZNLI; Da el estdo de todos los enlaces de señalizacion.
ZNEL:768&769; Indica los ET a los que se conectan los enlaces 768 y 769.
ZNLC:23,ACT; Activa el enlace 23.
ZNET:NA0; Da los ET y el enlace a los que pertenecen.
***** SUBIR OMUSIG, TRXSIG, TRX, BTS, Y BCF *****
ZUSI:ET,#et :; Estado ET.
ZDTI :::PCM=#pcm :; Estado de OMUSIG y TRXSIG (B0..., T1...) en el PCM.
ZDTC:B0###:WO:; Desbloquea el OMUSIG (Señalizador).
ZDTI:::PCM=#pcm:; Comprobar estado OMUSIG.
ZDTC:T1###:WO:; Desbloquea los TRXSIG.
ZDTI:::PCM=#pcm:; Comprobar estado TRXSIG.
ZERS:NAME=GL###,TRX=#trx:U:; Desbloquea TRX.ZERS:BTS=#bts,TRX=#trx:U:; Desbloquea TRX.
ZEQS :BTS=#bts :U:; Desbloquea BTS.
ZEFS:#bcf:U:; Desbloquea BCF.
ZEEI:BCF=#bcf; Estado BCF.
***** BCF *****
ZEEI:NAME=GL####; Indica que BCF está asociada a ese GL (#### No.GL y Sector).
ZEEI:BCF=# bcf; Indica el estado general de la BCF, sus BTS, sus TRX, permite saber que ET/PCM esta conectado a dicha BCF y su estado, el nombre del enlace D (OMUSIG) de esa BCF, GPRS y el numero de llamadas en cada BTS.
ZEFS:# bcf:L:; Bloquea la BCF.
ZEFS:# bcf:U:; Desbloquea la BCF.
ZEFR:#bcf:OMU; Reinicia la BCF (OMU). ZEFR:# bcf:SITE; Reinicia toda la BCF 23.
ZEDO; Lista las BCF que se encuentran bloqueadas.
***** BTS *****
ZEQS:BTS=# bts:L:FHO,20:; Bloquea BTS sin tumbar llamadas.
ZEQS:BTS=# bts:U:; Desbloquea BTS.
ZEQO:BTS=# bts:ALL:; Muestra parámetros de la BTS.
ZEQO:BTS=40:GPRS; Se ve el estado de la bts para GPRS entre otros datos
ZEQV:BTS=40:Y; habilito GPRS para esa bts
***** TRX *****
ZERO:BCF=# bcf:TRX=# trx; Permite ver el estado y parámetros de un TRX de una BCF.
ZERO:BCF=99,TRX=1; Entrega el estado del TRX 1 y de sus Canales, de la BCF 99.
ZERS:BTS=# bts,TRX=#trx,:L:FHO,20; Bloquea TRX sin tumbar llamadas.
ZERS:BTS=# bts,TRX=#trx,:U:; Desbloquea TRX.
ZERS:BTS=# bts:TRX=# trx,CH=# ch:L:FHO,20; Bloquea un Canal del TRX de una BTS.
ZERS:BTS=# bts:TRX=# trx,CH=# ch:U:; Desbloquea un Canal del TRX de una BTS.
ZERM:BTS=# bts,TRX=# trx:PREF=P; Configura al TRX de la BTS como canal de control preferido, es decir que este TRX tendrá el canal de control siempre, a menos que este dañado.
ZMCJ:PCM=431-31; Para mirar que slots tienen llamadas en curso.
***** PARAMETRO MAL *****
ZEBI; Para mirar MAL creadas en la BSC
ZEBE:33,800:FREQ=247&248&249&250&251:; Para crear MAL con sus frec. Hoping.
ZEBI:##; Para mirar MAL ##.
ZEQO:BTS=###:ALL; Para mirar MAL asignada a esa BTS.
ZEQS:NAME=GL####:L:FHO,20; Bloquea BTS.
ZEQA:BTS=223:MAL=33,MO=0,MS=1; Para asignar o cambiar MAL y parámetros MO y MS.
ZEQA:NAME=GL####:MAL=##; Para cambiar MAL.
ZEQS:NAME=GL####:U:FHO,20; Desbloquea BTS.
***** CAMBIAR FRECUENCIAS *****
ZERS:BTS=# bts,TRX=#trx,:L:FHO,20:; Bloquea TRX sin tumbar llamadas.
ZEQS:BTS=#bts:L:FHO,20:; Bloquea BTS sin tumbar llamadas.
ZERM:BTS=#bts,TRX=#trx:FREQ=###:; Setea frecuencia al TRX.
***** PARAMETROS NCC Y BCC *****
NOTA: Siempre el TSC debe ser igual al BCC.
ZEEI:NAME=GL####; Estado sector.
ZERO:BTS=###; Para mirar parámetros de los TRX como TSC.
ZERS:BTS=###,TRX=#,:L:FHO,20; Bloquea TRX sin tumbar llamadas.
ZERM:BTS=###,TRX=#:TSC=3: Cambia parámetro TSC.ZERO:BTS=###; Para mirar parámetros de los TRX como TSC.
ZEQS:BTS=###:L:FHO,20:; Bloquea BTS sin tumbar llamadas.
ZEQE:BTS=###:NCC=4,BCC=3; Cambia parámetros NCCy BCC.
ZEQO:BTS=###:ALL:; Para mirar parámetros de la BTS.
ZERS:BTS=###,TRX=#,:U:; Desbloquea TRX.
ZEQS:BTS=###:U:; Desbloquea BTS.
ZEEI:NAME=GL####; Estado sector.***** CREAR VECINDADES *****
PARA CREAR VECINDADES:EL AUCL=-47 EN LA MISMA BANDA Y DE 1900 A 850EL AUCL=-82 DE 850 A 1900EL PMRG=63 DE 1900 A 850EL PMRG=4 EN LA MISMA BANDA Y DE 850 A 1900
ZEAO:NAME=GL####; PARA MIRAR LAS VECINDADES CREADAS A ESA BTS.
ZEAC:NAME=GL####::ANAME=GL####::PMRG=63(1900850)4(LOSDEMAS),SL=-###,AUCL=-##,DRT=-##,:;
ZEAC:NAME=GL####::MCC=732,MNC=123,LAC=####,CI=4###:NCC=#,BCC=#,FREC=###:PMRG=63(1900850) 4 (LOS DEMAS) CREA VECINDAD EN BSC DIFERENTES.
***** PARAMETRO DE POTENCIA PMAX *****
ZEUO:BTS=###:; Para mirar PMAX.
ZEUG:BTS=###,PMAX1=#,PMAX2=#,:; Cambia parámetro PMAX.
***** PARAMETRO DE POTENCIA DMAX ***** MISZEQO:BTS=###:ALL; Para mirar DMAX. ZEQM:BTS=###:DMAX=##; Cambia parámetro DMAX.
***** PARAMETRO AUCL *****
ZEAM:NAME=GL###::LAC=4061o###,CI=4####::AUCL=##;PARA CAMBIAR AUCL EN BSC DIFERENTE.ZEAM:BTS=#bcf::ABTS=##::AUCL=##; Para cambiar AUCL.ZEAM:NAME=GL###::ANAME=GL###::AUCL=##; Para cambiar AUCLZEAM:NAME=GL###:::ASEG=###::AUCL=-##; Para AUCL hacia sector segmentado.ZEAM:SEG=###::ANAME=GL###::AUCL=-##; Para AUCL desde sector segmentado.ZEAM:SEG=###::ASEG=###::AUCL=-##; Para AUCL de sector segmentado hacia sector segmentado.
***** PARAMETRO PMRG *****
ZEAM:NAME=GL###::LAC=4061o###,CI=4####::PMRG=##;PARA CAMBIAR PMRG EN BSC DIFERENTE.ZEAM:NAME=GL###::ANAME=GL###::PMRG=##; Para cambiar PMRG
***** PARA MIRAR Y HABILITAR GPRS *****
ZEEI:BCF=#bcf; Los últimos números muestran HR y FR (Half y Full Rate) y el número debajo, son los canales GPRS (>=1) habilitados, si tiene 0 es porque no está habilitado.
SE HABILITA EL GPRS EN EL TRX QUE TIENE EL BCCH.ZERM:BTS=#bts,TRX=#trx:GTRX=Y; Habilita GPRS en el TRX.
ZERV:BTS=#bts:GENA=Y; Habilita GPRS en la BTS.
ZEQO:BTS=#bts:GPRS; Mirar estado de la BTS para GPRS.ZEQV:BTS=#bts:Y; Habilitar GPRS a la BTS.
***** SETEAR DFCA A UN TRX *****
ZERS:BTS=###,TRX=##:L:FHO,20; Bloquea TRX sin tumbar llamadas.ZERM:BTS=###,TRX=##:DFCA=Y; Pone DFCA.ZERS:BTS=###,TRX=##:U:; Desbloquea TRX.
***** PARAMETRO REO *****
ZEQM:BTS=#bts::REO=##; Para cambiar REO.
***** PARAMETRO LDR *****
ZEHS:BTS=#bts:LDR=##; Para cambiar LDR.
***** PARAMETRO EMS *****
ZEHG:NAME=GL####:EMS=Y;
***** PARAMETRO MSR *****
ZEHD:NAME=GL####:MSR=#;
***** PARAMETRO MSP *****
ZEHD:NAME=GL####:MSP=#;
***** PARAMETRO MSN *****
ZEHD:NAME=GL####:MSN=#;
***** PARAMETRO SL *****
ZEAM:NAME=GL####:ANAME=GL####:SL=-###;
***** PARAMETRO RXP *****
ZEOG:NAME=GL####:RXP=-###;
***** PARAMETROS FRL FRU *****
ZEQO:BTS=#bts:MIS:; Para mirar parametros FRL y FRU.
ZEQM:…………………:; Para cambiar valores.
***** PASOS PARA CREAR CELDA GSM *****
1- CREAR SEÑALIZADORES: LAPD’S : OMUSIG – TRX SIG’S
2- CREAR BCF.
3- CREAR BTS’S
4- CREAR PARAMETROS DE HOP ( HAND OVER )
5- CREAR PARAMETROS DE POC ( POTENCIA )
6- CREAR TRX’S
7- CREAR ADYACENCIAS
8- CREARLA CELDA EN EL MSC BTSM ( BTS EN MSC )
***** BORRAR BCF COMPLETAMENTE DE UNA BSC CUANDO ESTA HA TENIDO DFCA *****
ZEFM:25:SENA=F,;
ZEFM:25:CS=NONE,;
ZEXR:LMUA=25:;
ZQWR:BCF=25:TRE=2:;
ZEFD:25:;
ZEFL;
ZEXI;
ZQWL;
***** ESTADOS DE OPERACIÓN *****
EX EXECUTING
INU INACTIVATED BY USER
INS INACTIVATED BY SYSTEM
BLU BLOCKED BY USER
BLR BLOCKED BY REMOTE EXCHANGE
BLB BLOCKED BY USER AND REMOTE EXCHANGE
TST DATALINK TESTING
IBL INHIBITED LOCAL
IBR INHIBITED REMOTE
IBB INHIBITED LOCAL AND REMOTE
AD ACTIVATION DENIED
WO-EX normal working state.
WO-BU normal working state; device busy
WO-ID normal working state; device idle
WO-CL normal working state; device changing from WO-BU to WO-ID
BL-SY blocked by system
BL-US blocked by user
TE-AC test active
TE-ID test idle
MI-SY device missing; default state after restart
MI-US device missing; state set by the user
WO-EX: NORMALSP-EX: NORMALSE-NH: NORMAL
SE-OU: INCORRECTO (PROBLEMA)TE-EX: INCORRECTO (PROBLEMA)
*****************************************************************************************************************************
********************************************** MODELO PARA AMPLIACION **********************************************************************************************************************************************************
************
====================================================================Ampliación 850====================================================================
!Ver distriducion BCF y PCMZEEI:BCF=103;ZDTI:::PCM=110;
!Bloquear TRX 5,6,7,8 (Sector 2) y 9,10,11,12 (Sector 3)ZERS:BTS=103,TRX=1,:L:FHO,20:;ZERS:BTS=103,TRX=2,:L:FHO,20:;ZERS:BTS=103,TRX=3,:L:FHO,20:;ZERS:BTS=103,TRX=4,:L:FHO,20:;ZERS:BTS=104,TRX=5,:L:FHO,20:;ZERS:BTS=104,TRX=6,:L:FHO,20:;ZERS:BTS=104,TRX=7,:L:FHO,20:;ZERS:BTS=104,TRX=8,:L:FHO,20:;ZERS:BTS=105,TRX=9,:L:FHO,20:;ZERS:BTS=105,TRX=10,:L:FHO,20:;ZERS:BTS=105,TRX=11,:L:FHO,20:;ZERS:BTS=105,TRX=12,:L:FHO,20:;ZEEI:BCF=103;
!Bloquear BTS Sector 2 y 3ZEQS:BTS=103:L:;ZEQS:BTS=104:L:;ZEQS:BTS=105:L:;ZEEI:BCF=103;
!Bloquear BCFZEFS:103:L:;ZEEI:BCF=103;
!Borrar TRX 5,6,7,8 (Sector 2) y 9,10,11,12 (Sector 3)ZERD:BTS=104,TRX=5;
ZERD:BTS=104,TRX=6;ZERD:BTS=104,TRX=7;ZERD:BTS=104,TRX=8;ZERD:BTS=105,TRX=9;ZERD:BTS=105,TRX=10;ZERD:BTS=105,TRX=11;ZERD:BTS=105,TRX=12;ZEEI:BCF=103;
!Borrar BTS Sector 3 (105)ZEQD:BTS=105:Y:;ZEEI:BCF=103;
!Borrar TRX SIG 5,6,7,8 (Sector 2) y 9,10,11,12 (Sector 3)ZDTC:T1035:BL:;ZDTC:T1035:AD:;ZDSD:T1035;ZDTC:T1036:BL:;ZDTC:T1036:AD:;ZDSD:T1036;ZDTC:T1037:BL:;ZDTC:T1037:AD:;ZDSD:T1037;ZDTC:T1038:BL:;ZDTC:T1038:AD:;ZDSD:T1038;ZDTC:T1039:BL:;ZDTC:T1039:AD:;ZDSD:T1039;ZDTC:T103A:BL:;ZDTC:T103A:AD:;ZDSD:T103A;ZDTC:T103B:BL:;ZDTC:T103B:AD:;ZDSD:T103B;ZDTC:T103C:BL:;ZDTC:T103C:AD:;ZDSD:T103C;ZDTI:::PCM=110;
!CREAR TRX SIG 5 (Sector 1) ZDSE:T1035:BCSU,6:0,5:32,110-27,0:;ZDTI:::PCM=110;
!CREAR TRX 5 (Sector 1) ZERC:BTS=103,TRX=5:PREF=N,:FREQ=210,TSC=5,PCMTSL=110-9:DNAME=T1035:CH0=TCHD,CH1=-CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:; ZEEI:BCF=103;
!CREAR TRX SIG 7,8,9,10 (Sector 2) ZDSE:T1037:BCSU,6:0,7:32,110-28,0:;ZDSE:T1038:BCSU,5:0,8:32,110-28,4:;ZDSE:T1039:BCSU,6:0,9:32,110-29,0:;ZDSE:T103A:BCSU,6:0,10:32,110-29,4:;ZDTI:::PCM=110;
!CREAR TRX 7,8,9,10 (Sector 2) ZERC:BTS=104,TRX=7:PREF=P,GTRX=Y,:FREQ=213,TSC=5,PCMTSL=110-13:DNAME=T1037:CH0=-CH0=MBCCH,CH1=SDCCH,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:; ZERC:BTS=104,TRX=8:PREF=N,:FREQ=231,TSC=5,PCMTSL=110-15:DNAME=T1038:CH0=TCHD,CH1=-CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:; ZERC:BTS=104,TRX=9:PREF=N,:FREQ=240,TSC=5,PCMTSL=110-17:DNAME=T1039:CH0=TCHD,CH1=-CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:; ZERC:BTS=104,TRX=10:PREF=N,:FREQ=229,TSC=5,PCMTSL=110-19:DNAME=T103A:CH0=TCHD,CH1=-CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:; ZEEI:BCF=103;
!SECTOR 3____________________________________________________________________--------------------------------------------------------------------Borrar BCF = 280 (Sector 6)--------------------------------------------------------------------
!Bloquear TRX 1,2,3,4,5 (Sector 6) ZERS:BTS=108,TRX=1,:L:FHO,20:;ZERS:BTS=108,TRX=2,:L:FHO,20:;ZERS:BTS=108,TRX=3,:L:FHO,20:;ZERS:BTS=108,TRX=4,:L:FHO,20:;ZERS:BTS=108,TRX=5,:L:FHO,20:;ZEEI:BCF=280;
!Bloquear BTS Sector 6ZEQS:BTS=108:L:;ZEEI:BCF=280;
!Bloquear BCFZEFS:280:L:;ZEEI:BCF=280;
!Borrar TRX 1,2,3,4,5 (Sector 6) ZERD:BTS=108,TRX=1;ZERD:BTS=108,TRX=2;ZERD:BTS=108,TRX=3;ZERD:BTS=108,TRX=4;ZERD:BTS=108,TRX=5;ZEEI:BCF=280;
!Borrar BTS Sector 6 (108)ZEQD:BTS=108:Y:;ZEEI:BCF=280;
!Borrar BCF=280ZEFD:280;ZEEI:BCF=280;
!Borrar TRX SIG 1,2,3,4,5 (Sector 6)ZDTC:T2801:BL:;ZDTC:T2801:AD:;ZDSD:T2801;ZDTC:T2802:BL:;ZDTC:T2802:AD:;ZDSD:T2802;ZDTC:T2803:BL:;ZDTC:T2803:AD:;ZDSD:T2803;ZDTC:T2804:BL:;ZDTC:T2804:AD:;ZDSD:T2804;ZDTC:T2805:BL:;ZDTC:T2805:AD:;ZDSD:T2805;ZDTI:::PCM=111;
ZDTC:T1065:BL:;ZDTC:T1065:AD:;ZDSD:T1065;ZDTC:T106B:BL:;ZDTC:T106B:AD:;ZDSD:T106B;
ZDTI:::PCM=250;
!Borrar OMU SIG BCF=280ZDTC:B0280:BL:;ZDTC:B0280:AD:;ZDSD:B0280;ZDTI:::PCM=250;____________________________________________________________________
!CREAR OMUSIG BCF=280 NUEVA. EXISTE GROOMING.ZDSE:B0280:BCSU,2:62,1:32,250-31,0:; ZDTI:::PCM=250;
!CREAR TRX SIG SECTOR 3 (1,2,3,4,5) NUEVOSZDSE:T2801:BCSU,2:0,1:32,250-25,0:;ZDSE:T2802:BCSU,2:0,2:32,250-25,4:;ZDSE:T2803:BCSU,6:0,3:32,250-26,0:;ZDSE:T2804:BCSU,5:0,4:32,250-26,4:;ZDSE:T2805:BCSU,3:0,5:32,250-27,0:;ZDTI:::PCM=250;
!CREAR BASE CONTROL FUNCTION (BCF=280 850)ZEFC:0280,P:DNAME=B0280,REF=013,::::;ZEEI:BCF=280;
!CREAR BTS=280 SECTOR 3 850ZEQC:BCF=280,BTS=280,NAME=GL1413,REF=13:BAND=800,CI=41413:NCC=3,BCC=5:MCC=732,MNC=123,LAC=4061:HOP=RF,HSN1=10,:GENA=Y,RAC=60,;ZEQA:BTS=280:MAL=33,MO=2,MS=3,;
ZEEI:BCF=280;
!MODIFY CELL ACCESS PARAMETERSZEQF:BTS=280:BAR=N,;
!CREAR TRX SECTOR 3 (1,2,3,4,5) NUEVOSZERC:BTS=280,TRX=1:PREF=P,GTRX=Y,:FREQ=222,TSC=5,PCMTSL=250-1:DNAME=T2801:CH0=MBCCH,CH1=SDCCH,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:;ZERC:BTS=280,TRX=2:PREF=N,:FREQ=240,TSC=5,PCMTSL=250-3:DNAME=T2802:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:;ZERC:BTS=280,TRX=3:PREF=N,:FREQ=231,TSC=5,PCMTSL=250-5:DNAME=T2803:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:;ZERC:BTS=280,TRX=4:PREF=N,:FREQ=229,TSC=5,PCMTSL=250-7:DNAME=T2804:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:;ZERC:BTS=280,TRX=5:PREF=N,:FREQ=242,TSC=5,PCMTSL=250-9:DNAME=T2805:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:;ZEEI:BCF=280;
!CREATE POWER CONTROL PARAMETERSZEUC:BTS=280,REF=13:;
!CREATE HANDOVER CONTROL PARAMETERSZEHC:BTS=280,REF=13;
====================================================================Ampliación 1900====================================================================
!Ver distriducion BCF y PCMZEEI:BCF=106;ZDTI:::PCM=111;
!Bloquear TRX 5 (Sector 4) y 7,8,9,10,11(Sector 5)ZERS:BTS=106,TRX=1,:L:FHO,20:;ZERS:BTS=106,TRX=2,:L:FHO,20:;ZERS:BTS=106,TRX=3,:L:FHO,20:;ZERS:BTS=106,TRX=4,:L:FHO,20:;ZERS:BTS=106,TRX=5,:L:FHO,20:;ZERS:BTS=107,TRX=7,:L:FHO,20:;ZERS:BTS=107,TRX=8,:L:FHO,20:;ZERS:BTS=107,TRX=9,:L:FHO,20:;ZERS:BTS=107,TRX=10,:L:FHO,20:;ZERS:BTS=107,TRX=11,:L:FHO,20:;ZEEI:BCF=106;
!Bloquear BTS Sector 4 y 5ZEQS:BTS=106:L:FHO,20:;ZEQS:BTS=107:L:FHO,20:;ZEEI:BCF=106;
!Bloquear BCFZEFS:106:L:;ZEEI:BCF=106;
!Borrar TRX 5 (Sector 4) y 7,8,9,10,11 (Sector 5)ZERD:BTS=106,TRX=5;ZERD:BTS=107,TRX=7;ZERD:BTS=107,TRX=8;ZERD:BTS=107,TRX=9;ZERD:BTS=107,TRX=10;ZERD:BTS=107,TRX=11;ZEEI:BCF=106;
!Borrar TRX SIG 5 (Sector 4) y 7,8,9,10,11 (Sector 5)ZDTC:T1065:BL:;ZDTC:T1065:AD:;ZDSD:T1065;ZDTC:T1067:BL:;ZDTC:T1067:AD:;ZDSD:T1067;ZDTC:T1068:BL:;ZDTC:T1068:AD:;ZDSD:T1068;ZDTC:T1069:BL:;ZDTC:T1069:AD:;ZDSD:T1069;ZDTC:T106A:BL:;ZDTC:T106A:AD:;ZDSD:T106A;ZDTC:T106B:BL:;ZDTC:T106B:AD:;ZDSD:T106B;ZDTI:::PCM=111;ZDTI:::PCM=250;
!CREAR TRX SIG 5 (Sector 4) ZDSE:T1065:BCSU,3:0,5:32,111-27,0:;ZDTI:::PCM=111;
!CREAR TRX 5 (Sector 4) ZERC:BTS=106,TRX=5:PREF=N,:FREQ=636,TSC=5,PCMTSL=111-9:DNAME=T1065:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:; ZEEI:BCF=106;
!CREAR TRX SIG 7,8,9,10,11 (Sector 5) ZDSE:T1067:BCSU,4:0,7:32,111-28,0:;ZDSE:T1068:BCSU,5:0,8:32,111-28,4:;ZDSE:T1069:BCSU,6:0,9:32,111-29,0:;ZDSE:T106A:BCSU,3:0,10:32,111-29,4:;ZDSE:T106B:BCSU,2:0,11:32,111-30,0:;ZDTI:::PCM=111;
!CREAR TRX 7,8,9,10,11 (Sector 5)
ZERC:BTS=107,TRX=7:PREF=P,GTRX=Y,:FREQ=613,TSC=5,PCMTSL=111-13:DNAME=T1067:CH0=MBCCH,CH1=SDCCH,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:; ZERC:BTS=107,TRX=8:PREF=N,:FREQ=640,TSC=5,PCMTSL=111-15:DNAME=T1068:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:; ZERC:BTS=107,TRX=9:PREF=N,:FREQ=642,TSC=5,PCMTSL=111-17:DNAME=T1069:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:; ZERC:BTS=107,TRX=10:PREF=N,:FREQ=638,TSC=5,PCMTSL=111-19:DNAME=T106A:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:;ZERC:BTS=107,TRX=11:PREF=N,:FREQ=636,TSC=5,PCMTSL=111-21:DNAME=T106B:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:; ZEEI:BCF=106;
!SECTOR 6
!CREAR OMUSIG BCF=281 NUEVA. EXISTE GROOMING.ZDSE:B0281:BCSU,3:62,1:32,250-31,4:; ZDTI:::PCM=250;
!CREAR TRX SIG SECTOR 3 (1,2,3,4) NUEVOSZDSE:T2811:BCSU,6:0,1:32,250-28,0:;ZDSE:T2812:BCSU,5:0,2:32,250-28,4:;ZDSE:T2813:BCSU,4:0,3:32,250-29,0:;ZDSE:T2814:BCSU,3:0,4:32,250-29,4:;ZDSE:T2815:BCSU,2:0,5:32,250-30,0:;ZDTI:::PCM=250;
!CREAR BASE CONTROL FUNCTION (BCF=281 1900)ZEFC:0281,P:DNAME=B0281,REF=016,::::;ZEEI:BCF=281;
!CREAR BTS=281 SECTOR 3 1900ZEQC:BCF=281,BTS=281,NAME=GL1416,REF=16:BAND=1900,CI=41416:NCC=3,BCC=5:MCC=732,MNC=123,LAC=4061:HOP=RF,HSN1=10,:GENA=Y,RAC=60,;ZEQA:BTS=281:MAL=60,MO=2,MS=3,;ZEEI:BCF=281;
!MODIFY CELL ACCESS PARAMETERSZEQF:BTS=281:BAR=N,;
!CREAR TRX SECTOR 6 (1,2,3,4,5) NUEVOSZERC:BTS=281,TRX=1:PREF=P,GTRX=Y,:FREQ=622,TSC=5,PCMTSL=250-13:DNAME=T2811:CH0=MBCCH,CH1=SDCCH,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:;ZERC:BTS=281,TRX=2:PREF=N,:FREQ=642,TSC=5,PCMTSL=250-15:DNAME=T2812:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:;ZERC:BTS=281,TRX=3:PREF=N,:FREQ=638,TSC=5,PCMTSL=250-17:DNAME=T2813:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:;
ZERC:BTS=281,TRX=4:PREF=N,:FREQ=640,TSC=5,PCMTSL=250-19:DNAME=T2814:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:;ZERC:BTS=281,TRX=5:PREF=N,:FREQ=636,TSC=5,PCMTSL=250-21:DNAME=T2815:CH0=TCHD,CH1=TCHD,CH2=TCHD,CH3=TCHD,CH4=TCHD,CH5=TCHD,CH6=TCHD,CH7=TCHD,:;ZEEI:BCF=281;
!CREATE POWER CONTROL PARAMETERSZEUC:BTS=281,REF=16:;
!CREATE HANDOVER CONTROL PARAMETERSZEHC:BTS=281,REF=16;
====================================================================SUBIR BCF 850 (103)====================================================================
!VER DISTRIBUCION ACTUAL BCF Y PCMZEEI:BCF=103;ZDTI:::PCM=110;
!PASAR TRXSIG SECTOR 1 (5) Y SECTOR 2 (7,8,9,10) A ESTADO WORKINGZDTC:T1035:WO;ZDTC:T1037:WO;ZDTC:T1038:WO;ZDTC:T1039:WO;ZDTC:T103A:WO;ZDTI:::PCM=110;
!DESBLOQUEAR TRX SECTOR 1 (1,2,3,4,5) Y SECTOR 2 (7,8,9,10)ZERS:BTS=103,TRX=1:U:;ZERS:BTS=103,TRX=2:U:;ZERS:BTS=103,TRX=3:U:;ZERS:BTS=103,TRX=4:U:;ZERS:BTS=103,TRX=5:U:;ZERS:BTS=104,TRX=7:U:;ZERS:BTS=104,TRX=8:U:;ZERS:BTS=104,TRX=9:U:;ZERS:BTS=104,TRX=10:U:;ZEEI:BCF=103;
!DESBLOQUEAR BTS DE SECTOR 2ZEQS:BTS=103:U:;ZEQS:BTS=104:U:;ZEEI:BCF=103;
!DESBLOQUEAR BCFZEFS:103:U;ZEEI:BCF=103;
====================================================================SUBIR BCF 1900 (106)====================================================================
!Ver distriducion BCF y PCMZEEI:BCF=106;ZDTI:::PCM=111;
!PASAR TRXSIG SECTOR 4 (5) Y SECTOR 2 (7,8,9,10,11) A ESTADO WORKINGZDTC:T1065:WO;ZDTC:T1067:WO;ZDTC:T1068:WO;ZDTC:T1069:WO;ZDTC:T106A:WO;ZDTC:T106B:WO;ZDTI:::PCM=111;
!DESBLOQUEAR TRX SECTOR 4 (5) Y SECTOR 2 (7,8,9,10,11)ZERS:BTS=106,TRX=1:U:;ZERS:BTS=106,TRX=2:U:;ZERS:BTS=106,TRX=3:U:;ZERS:BTS=106,TRX=4:U:;ZERS:BTS=106,TRX=5:U:;ZERS:BTS=107,TRX=7:U:;ZERS:BTS=107,TRX=8:U:;ZERS:BTS=107,TRX=9:U:;ZERS:BTS=107,TRX=10:U:;ZERS:BTS=107,TRX=11:U:;ZEEI:BCF=106;
!DESBLOQUEAR BTS DE SECTOR 4,5ZEQS:BTS=106:U:;ZEQS:BTS=107:U:;ZEEI:BCF=106;
!DESBLOQUEAR BCFZEFS:106:U;ZEEI:BCF=106;
====================================================================SUBIR BCF 850/1900 (280/281)====================================================================
!VER DISTRUBUCION ACTUAL BCF Y PCMZEEI:BCF=280;ZEEI:BCF=281;ZDTI:::PCM=250;
!PASAR TRXSIG Y OMUSIG (1,2,3,4,5 SEC 3)850 (1,2,3,4,5 SEC 6)1900 A ESTADO WORKINGZDTC:B0280:WO;ZDTC:T2801:WO;ZDTC:T2802:WO;ZDTC:T2803:WO;ZDTC:T2804:WO;ZDTC:T2805:WO;ZDTC:B0281:WO;ZDTC:T2811:WO;ZDTC:T2812:WO;ZDTC:T2813:WO;ZDTC:T2814:WO;
ZDTC:T2815:WO;ZDTI:::PCM=250;
!DESBLOQUEAR TRX (1,2,3,4,5 SEC 3)850 (1,2,3,4,5 SEC 6)1900ZERS:BTS=280,TRX=1:U:;ZERS:BTS=280,TRX=2:U:;ZERS:BTS=280,TRX=3:U:;ZERS:BTS=280,TRX=4:U:;ZERS:BTS=280,TRX=5:U:;ZEEI:BCF=280;ZERS:BTS=281,TRX=1:U:;ZERS:BTS=281,TRX=2:U:;ZERS:BTS=281,TRX=3:U:;ZERS:BTS=281,TRX=4:U:;ZERS:BTS=281,TRX=5:U:;ZEEI:BCF=281;
!DESBLOQUEAR BTS DE SECTOR 3 (850/1900)ZEQS:BTS=280:U:;ZEEI:BCF=280;ZEQS:BTS=281:U:;ZEEI:BCF=281;
!DESBLOQUEAR BCFZEFS:280:U;ZEEI:BCF=280;ZEFS:281:U;ZEEI:BCF=281;
====================================================================CREAR VECINDADES BTS 280 (Sector 3 850)====================================================================
PARA CREAR VECINDADES:EL AUCL=-47 EN LA MISMA BANDA Y DE 1900 A 850EL AUCL=-82 DE 850 A 1900EL PMRG=63 DE 1900 A 850EL PMRG=4 EN LA MISMA BANDA Y DE 850 A 1900
SALIENTESZEAC:NAME=GL1413::ANAME=GLO221::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO223::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO224::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO571::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO572::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO573::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO574::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO575::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO576::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO663::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO666::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO923::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GLO926::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GL1411::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GL1412::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GL1414::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;
ZEAC:NAME=GL1413::ANAME=GL1415::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GL2502::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GL2505::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAO:NAME=GL1413;
ENTRANTESZEAC:NAME=GL0221::ANAME=GL1413::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0223::ANAME=GL1413::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0224::ANAME=GL1413::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0571::ANAME=GL1413::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0572::ANAME=GL1413::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0573::ANAME=GL1413::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0574::ANAME=GL1413::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0575::ANAME=GL1413::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0576::ANAME=GL1413::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0663::ANAME=GL1413::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0666::ANAME=GL1413::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0923::ANAME=GL1413::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0926::ANAME=GL1413::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1411::ANAME=GL1413::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1412::ANAME=GL1413::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1414::ANAME=GL1413::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1415::ANAME=GL1413::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GL1413::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL2502::ANAME=GL1413::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL2505::ANAME=GL1413::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;
====================================================================CREAR VECINDADES BTS 281 (Sector 6 1900)====================================================================
SALIENTESZEAC:NAME=GL1416::ANAME=GLO221::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GLO223::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GLO224::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GLO572::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GLO573::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GLO574::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GLO575::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GLO576::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GLO923::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GLO926::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GL1411::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GL1412::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GL1413::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GL1414::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GL1415::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GL2502::PMRG=63,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1416::ANAME=GL2505::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAO:NAME=GL1416;
ENTRANTESZEAC:NAME=GL0221::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0223::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;
ZEAC:NAME=GL0224::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0572::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0573::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0574::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0575::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0576::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0923::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL0926::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1411::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1412::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1413::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1414::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL1415::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL2502::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;ZEAC:NAME=GL2505::ANAME=GL1416::PMRG=4,SL=-102,AUCL=-82,DRT=-85,:;
*****************************************************************************************************************************
***************************************** MODELO CREACION DE ALARMAS ********************************************************************************************************************************************************
************
ZEFX:217:INBR=1:ROU=NOT,POL=OPEN,:SEV=AL3,TID=0:;
ZEFX:217:INBR=2:ROU=ACT,POL=OPEN,:SEV=AL2,TID=32:;
ZEFX:217:INBR=3:ROU=ACT,POL=OPEN,:SEV=AL3,TID=33:;
ZEFX:217:INBR=4:ROU=ACT,POL=OPEN,:SEV=AL3,TID=34:;
ZEFX:217:INBR=5:ROU=ACT,POL=OPEN,:SEV=AL2,TID=35:;
ZEFX:217:INBR=6:ROU=ACT,POL=OPEN,:SEV=AL3,TID=36:;
ZEFX:217:INBR=7:ROU=NOT,POL=OPEN,:SEV=AL3,TID=0:;
ZEFX:217:INBR=8:ROU=ACT,POL=OPEN,:SEV=AL2,TID=38:;
ZEFX:217:INBR=9:ROU=ACT,POL=CLOSED,:SEV=AL3,TID=39:;
ZEFX:217:INBR=10:ROU=NOT,POL=OPEN,:SEV=AL3,TID=0:;
ZEFX:217:INBR=11:ROU=ACT,POL=OPEN,:SEV=AL1,TID=41:;
ZEFX:217:INBR=12:ROU=ACT,POL=OPEN,:SEV=AL3,TID=42:;
ZEFX:217:INBR=13:ROU=NOT,POL=OPEN,:SEV=AL3,TID=0:;
ZEFX:217:INBR=14:ROU=NOT,POL=OPEN,:SEV=AL3,TID=0:;
ZEFX:217:INBR=15:ROU=ACT,POL=CLOSED,:SEV=AL2,TID=45:;
ZEFX:217:INBR=16:ROU=NOT,POL=OPEN,:SEV=AL3,TID=0:;
ZEFX:217:INBR=17:ROU=ACT,POL=CLOSED,:SEV=AL3,TID=47:;
ZEFX:217:INBR=18:ROU=ACT,POL=CLOSED,:SEV=AL1,TID=48:;
ZEFX:217:INBR=19:ROU=ACT,POL=CLOSED,:SEV=AL3,TID=49:;
ZEFX:217:INBR=20:ROU=NOT,POL=OPEN,:SEV=AL3,TID=0:;
ZEFX:217:INBR=21:ROU=NOT,POL=OPEN,:SEV=AL3,TID=0:;
ZEFX:217:INBR=22:ROU=NOT,POL=OPEN,:SEV=AL3,TID=0:;
ZEFX:217:INBR=23:ROU=ACT,POL=OPEN,:SEV=AL2,TID=53:;
ZEFX:217:INBR=24:ROU=NOT,POL=OPEN,:SEV=AL3,TID=0:;
ZEOL:217;
ZEFO:217:IOP;
*****************************************************************************************************************************
************************************************ MODELO PARA DFCA *****************************************************************************************************************************************************************
************************************************* DATA STANDBY *************************************
! CREACION DE Q1 !ZQWA:BCF=163:TRE=2:10;
! CREACION DE LMU AREA !ZEXA:LMUA=163::BCF=163,TRE=2,FNO=14,:LTO=1;
! CREACION DE LA CADENA DE SINCRONISMO !ZEFM:163:CS=LAB,SENA=T,ADD=166;
! CREACION DE LISTAS BAL !ZEBC:54,MULTI:210&211&212&213&214&215&216&217&218&219&220&221&222&223&224&225&226&227&247&613&617&618&619&621&622&623&626;ZEBC:55,MULTI:210&211&212&213&214&215&216&217&218&219&220&221&222&223&224&225&226&227&247&612&617&621&624&626;ZEBC:56,MULTI:210&211&212&213&214&215&216&217&218&219&220&221&222&223&224&225&226&227&247&614&615&617&619&621&624&626;ZEBC:57,MULTI:612&613&614&615&616&617&618&619&620&621&622&623&624&625&626&627&629&631&213&214&217&218&219&221&222&226;ZEBC:58,MULTI:612&613&614&615&616&617&618&619&620&621&622&623&624&625&626&627&629&631&217&221&226&227;ZEBC:59,MULTI:612&613&614&615&616&617&618&619&620&621&622&623&624&625&626&627&629&631&214&217&219&221&224&226&227;
! ATACHADO DE LISTAS BAL A LAS BTS !ZEQB:BTS=163:IDLE=54,ACT=IDLE;ZEQB:BTS=164:IDLE=55,ACT=IDLE;ZEQB:BTS=165:IDLE=56,ACT=IDLE;ZEQB:BTS=166:IDLE=57,ACT=IDLE;ZEQB:BTS=167:IDLE=58,ACT=IDLE;ZEQB:BTS=168:IDLE=59,ACT=IDLE;
! COLOCAR BTS EN MODO STANDBY !ZEQM:BTS=163::::DMOD=1;ZEQM:BTS=164::::DMOD=1;ZEQM:BTS=165::::DMOD=1;ZEQM:BTS=166::::DMOD=1;ZEQM:BTS=167::::DMOD=1;ZEQM:BTS=168::::DMOD=1;
Nota: si la orden manda a modificar algún parámetro. Realizarlo antes de desbloquear la celda nueva.
ZEQY:BTS=163:ARLT=20;ZEQY:BTS=164:ARLT=20;ZEQY:BTS=165:ARLT=20;ZEQY:BTS=166:ARLT=20;
ZEQY:BTS=167:ARLT=20;ZEQY:BTS=168:ARLT=20;
ZEQG:BTS=163:RLT=20;ZEQG:BTS=164:RLT=20;ZEQG:BTS=165:RLT=20;ZEQG:BTS=166:RLT=20;ZEQG:BTS=167:RLT=20;ZEQG:BTS=168:RLT=20;
********************************** DATA ACTIVA ***** *****************************
! REALIZAR UN FALL BACK ANTES DE COMENZAR !
! Creación y Activación de Listas DMAL !
Estas ya deben estar creadas.
! Creación de Listas DUMAL !
Estas ya deben estar creadas.
! CAMBIAR FLAG EN TRX - Online !
ZERM:BTS=163,TRX=2:DFCA=Y;ZERM:BTS=163,TRX=3:DFCA=Y;ZERM:BTS=163,TRX=4:DFCA=Y;ZERM:BTS=164,TRX=6:DFCA=Y;ZERM:BTS=164,TRX=7:DFCA=Y;ZERM:BTS=164,TRX=8:DFCA=Y;ZERM:BTS=165,TRX=10:DFCA=Y;ZERM:BTS=165,TRX=11:DFCA=Y;ZERM:BTS=165,TRX=12:DFCA=Y;ZERM:BTS=166,TRX=2:DFCA=Y;ZERM:BTS=166,TRX=3:DFCA=Y;ZERM:BTS=166,TRX=4:DFCA=Y;ZERM:BTS=167,TRX=6:DFCA=Y;ZERM:BTS=167,TRX=7:DFCA=Y;ZERM:BTS=167,TRX=8:DFCA=Y;ZERM:BTS=168,TRX=10:DFCA=Y;ZERM:BTS=168,TRX=11:DFCA=Y;ZERM:BTS=168,TRX=12:DFCA=Y;
! COLOCAR DFCA ACTIVO Y CAMBIAR PARAMETROS DE BTS Y GPRS ! - OFFLINE
ZEFS:163:L;ZEFS:166:L;
ZEQS:BTS=163:L;ZEQS:BTS=164:L;ZEQS:BTS=165:L;ZEQS:BTS=166:L;ZEQS:BTS=167:L;ZEQS:BTS=168:L;
ZEQM:BTS=163:MBR=1,TRP=2,ULN=-110,DLN=-110,TRIH=1,FRL=55,FRU=75:::DMOD=2,FHR=15,FAHT=10,FHH=3;ZEQM:BTS=164:MBR=1,TRP=2,ULN=-110,DLN=-110,TRIH=1,FRL=55,FRU=75:::DMOD=2,FHR=15,FAHT=10,FHH=3;ZEQM:BTS=165:MBR=1,TRP=2,ULN=-110,DLN=-110,TRIH=1,FRL=55,FRU=75:::DMOD=2,FHR=15,FAHT=10,FHH=3;ZEQM:BTS=166:MBR=2,TRP=2,ULN=-110,DLN=-110,TRIH=1,FRL=55,FRU=75:::DMOD=2,FHR=15,FAHT=10,FHH=3;ZEQM:BTS=167:MBR=2,TRP=2,ULN=-110,DLN=-110,TRIH=1,FRL=55,FRU=75:::DMOD=2,FHR=15,FAHT=10,FHH=3;ZEQM:BTS=168:MBR=2,TRP=2,ULN=-110,DLN=-110,TRIH=1,FRL=55,FRU=75:::DMOD=2,FHR=15,FAHT=10,FHH=3;
ZEQV:BTS=163:CDED=1,CDEF=35,BFG=1;ZEQV:BTS=164:CDED=1,CDEF=35,BFG=1;ZEQV:BTS=165:CDED=1,CDEF=35,BFG=1;ZEQV:BTS=166:CDED=1,CDEF=35,BFG=1;ZEQV:BTS=167:CDED=1,CDEF=35,BFG=1;ZEQV:BTS=168:CDED=1,CDEF=35,BFG=1;
ZEQA:BTS=163:DUMAL=600,DMAL=2001&2002,OPE=A;ZEQA:BTS=164:DUMAL=600,DMAL=2001&2002,OPE=A;ZEQA:BTS=165:DUMAL=600,DMAL=2001&2002,OPE=A;ZEQA:BTS=166:DUMAL=601,DMAL=2003&2004,OPE=A;ZEQA:BTS=167:DUMAL=601,DMAL=2003&2004,OPE=A;ZEQA:BTS=168:DUMAL=601,DMAL=2003&2004,OPE=A;
ZEQS:BTS=163:U;ZEQS:BTS=164:U;ZEQS:BTS=165:U;ZEQS:BTS=166:U;ZEQS:BTS=167:U;ZEQS:BTS=168:U;
ZEFS:163:U;ZEFS:166:U;
! PARAMETROS HOC ! - ONLINE
ZEHG:BTS=163:EIC=Y,EIH=Y;ZEHG:BTS=164:EIC=Y,EIH=Y;ZEHG:BTS=165:EIC=Y,EIH=Y;ZEHG:BTS=166:EIC=Y,EIH=Y;ZEHG:BTS=167:EIC=Y,EIH=Y;ZEHG:BTS=168:EIC=Y,EIH=Y;
ZEHB:BTS=163:IHRF=1,IHRH=5,QDRF=4,QDRH=3,QURF=4,QURH=3;ZEHB:BTS=164:IHRF=1,IHRH=5,QDRF=4,QDRH=3,QURF=4,QURH=3;
ZEHB:BTS=165:IHRF=1,IHRH=5,QDRF=4,QDRH=3,QURF=4,QURH=3;ZEHB:BTS=166:IHRF=1,IHRH=5,QDRF=4,QDRH=3,QURF=4,QURH=3;ZEHB:BTS=167:IHRF=1,IHRH=5,QDRF=4,QDRH=3,QURF=4,QURH=3;ZEHB:BTS=168:IHRF=1,IHRH=5,QDRF=4,QDRH=3,QURF=4,QURH=3;
ZEHI:BTS=163:IDR=-70,IDP=2,IDN=3,IUR=-70,IUP=2,IUN=3;ZEHI:BTS=164:IDR=-70,IDP=2,IDN=3,IUR=-70,IUP=2,IUN=3;ZEHI:BTS=165:IDR=-70,IDP=2,IDN=3,IUR=-70,IUP=2,IUN=3;ZEHI:BTS=166:IDR=-70,IDP=2,IDN=3,IUR=-70,IUP=2,IUN=3;ZEHI:BTS=167:IDR=-70,IDP=2,IDN=3,IUR=-70,IUP=2,IUN=3;ZEHI:BTS=168:IDR=-70,IDP=2,IDN=3,IUR=-70,IUP=2,IUN=3;
! PARAMETROS POC ! - ONLINE
ZEUS:BTS=163:LDR=-87,UDR=-75,LUR=-87,UUR=-75;ZEUS:BTS=164:LDR=-87,UDR=-75,LUR=-87,UUR=-75;ZEUS:BTS=165:LDR=-87,UDR=-75,LUR=-87,UUR=-75;ZEUS:BTS=166:LDR=-87,UDR=-75,LUR=-87,UUR=-75;ZEUS:BTS=167:LDR=-87,UDR=-75,LUR=-87,UUR=-75;ZEUS:BTS=168:LDR=-87,UDR=-75,LUR=-87,UUR=-75;
ZEUQ:BTS=163:LDR=4,LDP=1,LDN=1,UDR=2,UDP=1,UDN=1,LUR=4,LUP=1,LUN=1,UUR=2,UUP=1,UUN=1;ZEUQ:BTS=164:LDR=4,LDP=1,LDN=1,UDR=2,UDP=1,UDN=1,LUR=4,LUP=1,LUN=1,UUR=2,UUP=1,UUN=1;ZEUQ:BTS=165:LDR=4,LDP=1,LDN=1,UDR=2,UDP=1,UDN=1,LUR=4,LUP=1,LUN=1,UUR=2,UUP=1,UUN=1;ZEUQ:BTS=166:LDR=4,LDP=1,LDN=1,UDR=2,UDP=1,UDN=1,LUR=4,LUP=1,LUN=1,UUR=2,UUP=1,UUN=1;ZEUQ:BTS=167:LDR=4,LDP=1,LDN=1,UDR=2,UDP=1,UDN=1,LUR=4,LUP=1,LUN=1,UUR=2,UUP=1,UUN=1;ZEUQ:BTS=168:LDR=4,LDP=1,LDN=1,UDR=2,UDP=1,UDN=1,LUR=4,LUP=1,LUN=1,UUR=2,UUP=1,UUN=1;
ZEUB:BTS=163:LDRF=4,UDRF=2,LURF=4,UURF=2,LDRH=2,UDRH=0,LURH=2,UURH=0;ZEUB:BTS=164:LDRF=4,UDRF=2,LURF=4,UURF=2,LDRH=2,UDRH=0,LURH=2,UURH=0;ZEUB:BTS=165:LDRF=4,UDRF=2,LURF=4,UURF=2,LDRH=2,UDRH=0,LURH=2,UURH=0;ZEUB:BTS=166:LDRF=4,UDRF=2,LURF=4,UURF=2,LDRH=2,UDRH=0,LURH=2,UURH=0;ZEUB:BTS=167:LDRF=4,UDRF=2,LURF=4,UURF=2,LDRH=2,UDRH=0,LURH=2,UURH=0;ZEUB:BTS=168:LDRF=4,UDRF=2,LURF=4,UURF=2,LDRH=2,UDRH=0,LURH=2,UURH=0;
! CAMBIO DE TIMERS EN LOS BCF ! - ONLINE
ZEFM:163::T200F=240;ZEFM:166::T200F=240;
DAR UN UPLOAD DEL BSC
******************************************* COMANDOS DE MSC *******************************************
ZQRI; Entrega la dirección IP del elemento en que este abierta la sesión MML.
ZQNS; Permite ver las sesiones MML que se encuentren abiertas en un dispositivo. También entrega los nombres de usuario que han abierto las sesiones.ZEFS
ZEOL::NR=7745; Lista todas las alarmas 7745 en la BSC donde este abierta la sesión MML.
ZMVP:MSISDN:573103804552; Indica el numero serial del teléfono (IMEI).
ZMIO:MSISDN:573103804552; (HLR) Muestra las características del movil cuyo numero es el 310380452.
ZMSO:IMSI=732101000009266; (HLR) Muestra los servicios suplementarios del movil.
ZMAN:IMSI=732101000009266; (HLR) Verifica si la intedridad en el AUC es correcta.
ZMAO:IMSI=732101000009266; (HLR) Verifica algoritmos A3 A8 y encripcion.
ZMEO:IMEI=01013750033161; (HLR) Verifica si un serial esta en una lista y muestra la causa
ZMVO:MSISDN=573103804552; (VLR) Da la ubicación del móvil con el numero indicado. El resultado es de la forma 053d, donde 05 es el numero de BCF y 3 es el sector.
ZSUC:TCSM,72:SE; Coloca al transcoder 72 en estado Separate Out of Service. Para pasar al estado Working (WO) se debe pasar antes por el modo Test (TE).
ZUSI:TCSM; Entrega el estado de todos los transcoder.
ZUSU:TCSM,40:C=TOT; Reinicia el transcoder 40.
ZIFI:STU:GSMCHA:S; Indica el porcentaje de ocupación del dispositivo de agravación GSMCHA (Charging).
ZWAE:1A; Da las alarmas de Hardware del gabinete 1 de la fila A de la MSC o sistema donde se digite. El formato de coordenadas es 1A002-01, donde 002 es el nivel dentro del gabinete 1A y el 01 es la posición dentro del nivel 002.
ZWIT:U:; Entrega un listado de todos los dispositivos y sus coordenadas.
ZIFO:STU:GSMCHA:; ( miramos estado) todos los archivos estan Full en el HLR.
ZIFS:STU:GSMCHA:,FUL,:T:; esto transfiere archivos en forma manual en el HLR.
ZIFO:CHU,0:GSMCHA:; ( miramos estado) todos los archivos estan Full en la MSC.
ZIFS:CHU,0:GSMCHA:,FUL,:T:; esto transfiere archivos en forma manual en la MSC.
ZMXM::AUTH=N; Para deshabilitar la autenticacion en los MSC:
ZMXM::AUTH=Y; Para habilitar la autenticacion en MSC:
ZWQO:CR; Lista los Fall Back creados en el SOMAFI.
ZWQD:DIRE= FB220603:MAFILE; Borra el Fall Back FB220603.
ZWKS:MODE=FULL,NAME=FB240703,DIRE=FB240703; Crea el Fall Back FB240703.
ZWKI; Indica como va el proceso de creasion del Fall Back.