Sheet No. 1 OF 5 1 Plan prepared by: Schlumberger Water Services USA Inc. 1567 Hayley Ln, Ste 202 Fort Myers, FL 33907 Ph. (239) 481-6494 Engineer CA License No. 27716 William S. Manahan, P.E. Florida Professional Engineer License No. 51423 Drawn by: Designed by: Checked by: Approved by: Scale: WSM WDW RGM WSM NTS Date: 02/03/2016 Project No. 0130-0563 Date: 03/04/2016 Project Phase No. 3 COLLIER COUNTY PUBLIC UTILITIES DIVISION SOUTH RO WELLFIELD IMPROVEMENTS PROJECT LOCATION MAP COLLIER COUNTY, FLORIDA BOARD OF COUNTY COMMISSIONERS Donna Fiala DISTRICT 1 COMMISSIONER Georgia A. Hiller DISTRICT 2 COMMISSIONER Tom Henning DISTRICT 3 COMMISSIONER Penny Taylor DISTRICT 4 COMMISSIONER Tim Nance DISTRICT 5 COMMISSIONER PUBLIC UTILITIES DIVISION LEO E. OCHS, JR. COUNTY MANAGER GEORGE YILMAZ, Ph.D., P.E. PUBLIC UTILITIES ADMINISTRATOR STEVE MESSNER WATER DIRECTOR ALICIA ABBOTT COUNTY PROJECT MANAGER PAM LIBBY DISTRIBUTION AND WELLFIELD MANAGER SHEET TITLE 1 TITLE SHEET & LOCATION MAP 2 GENERAL NOTES / SITE MAP 3 TYPICAL WELLHEAD PLANS AND SECTIONS 4 TYPICAL WELLHEAD PHOTOS 5 SPECIFICATIONS COLLIER COLLIER LEE LEE HENDRY HENDRY I-75 Alico Rd Corkscrew Rd S T a m i a m i Trl E s t e r o B lvd O l d41 R d I m p e r i a l P k w y Coconut Rd Williams Rd Hickory Blvd I-75 § ¨ ¦ 75

Upload: vucong

Post on 14-Feb-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Sheet No.

1 OF 5

1

Plan prepared by:Schlumberger Water Services USA Inc.

1567 Hayley Ln, Ste 202Fort Myers, FL 33907Ph. (239) 481-6494

Engineer CA License No. 27716William S. Manahan, P.E.

Florida Professional Engineer License No. 51423

Drawn by:

Designed by:

Checked by:

Approved by:

Scale:

WSM

WDW

RGM

WSM

NTS

Date: 02/03/2016

Project No. 0130-0563

Date: 03/04/2016

Project Phase No. 3

COLLIER COUNTY PUBLIC UTILITIES DIVISIONSOUTH RO WELLFIELD IMPROVEMENTS

PROJECT LOCATION MAPCOLLIER COUNTY, FLORIDA

BOARD OF COUNTY COMMISSIONERS

Donna Fiala DISTRICT 1 COMMISSIONERGeorgia A. Hiller DISTRICT 2 COMMISSIONERTom Henning DISTRICT 3 COMMISSIONERPenny Taylor DISTRICT 4 COMMISSIONERTim Nance DISTRICT 5 COMMISSIONER

PUBLIC UTILITIES DIVISION

LEO E. OCHS, JR. COUNTY MANAGERGEORGE YILMAZ, Ph.D., P.E. PUBLIC UTILITIES ADMINISTRATORSTEVE MESSNER WATER DIRECTORALICIA ABBOTT COUNTY PROJECT MANAGERPAM LIBBY DISTRIBUTION AND WELLFIELD MANAGER

SHEET TITLE

1 TITLE SHEET & LOCATION MAP

2 GENERAL NOTES / SITE MAP

3 TYPICAL WELLHEAD PLANS AND SECTIONS

4 TYPICAL WELLHEAD PHOTOS

5 SPECIFICATIONS

COLLIERCOLLIER

LEELEE

HE

ND

RY

HE

ND

RY

I-75

Alico Rd

Corkscrew Rd

ST a

mia

miT

rlEs ter

oB

lvd

Ol d

41

Rd

Impe ria

lP

kw

y

Coconut Rd

Williams Rd

Hickory

Blvd

I-75

§̈¦75

Sheet No.

2 OF 5

2

Plan prepared by:Schlumberger Water Services USA Inc.

1567 Hayley Ln, Ste 202Fort Myers, FL 33907Ph. (239) 481-6494

Engineer CA License No. 27716William S. Manahan, P.E.

Florida Professional Engineer License No. 51423

Drawn by:

Designed by:

Checked by:

Approved by:

Scale:

WSM

WDW

RGM

WSM

NTS

Date: 02/03/2016

Project No. 0130-0563

Date: 02/03/2016

Project Phase No. 3

Location Map

GENERAL PROJECT INFORMATION1. THE INTENT OF THIS PROJECT IS TO IMPROVE THE EXISTING WELLHEAD INFRASTRUCTURE FOR TWENTY (20) WELLS IN THE COLLIER COUNTY SOUTH RO WELLFIELD. THESE INCLUDE WELLS 18S THROUGH 38S WITH THE EXCEPTION OF WELL 32S, AS DETAILED IN THE PLANS. THE IMPROVEMENTS INCLUDE THE INSTALLATION OF 6-INCH DIAMETER ISOLATION VALVES, STAINLESS STEEL PIPING AS NEEDED, AND NEW CHECK VALVES. ALL MATERIALS SHALL BE 316 STAINLESS STEEL, PICKLED AND PASSIVIZED. THE CONTRACTOR WILL NEED TO PERFORM FIELD MEASUREMENTS TO VERIFY DIMENSIONS FOR PROPER FITTING. SPACERS OR ALTERATIONS TO THE PIPING LENGTHS MAY BE REQUIRED INCLUDING CUTTING AND WELDING STAINLESS STEEL PIPING, IF NECESSARY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECONNECTING THE AIR RELEASE VALVES AND OTHER APPURTENANCES, IF NECESSARY.2. ALL WELLS OPERATE UNDER ARTESIAN PRESSURE. IN ORDER TO PERFORM THE PROPOSED IMPROVEMENTS, THE CONTRACTOR MUST FIRST SUBCONTRACT THE WORK TO A FLORIDA LICENSED DRILLER TO SUPPRESS THE ARTESIAN FLOW IN EACH WELL. THE TECHNICAL SPECIFICATIONS FOR SALT PLUGGING THE WELLS ARE LOCATED BELOW. THIS PROCEDURE MUST BE PERFORMED BEFORE REPLACEMENT OF ANY INFRASTRUCTURE. THE CONTRACTOR SHALL SUBMIT A CONSTRUCTION SEQUENCING SCHEDULE AS PART OF INITIAL SUBMITTALS. ONLY TWO WELLS MAY BE TAKEN OUT OF SERVICE AT A TIME. THE CONTRACTOR SHALL COORDINATE WITH THE COUNTY AND PROVIDE A 24-HOUR NOTIFICATION PRIOR TO INITIATING SALT PLUGGING ON ANY WELL. ALL NEW MATERIALS SHALL BE ONSITE PRIOR TO INITIATING SALT PLUGGING. IT IS RECOMMENDED THE CONTRACTOR PERFORM A SITE VISIT TO EACH WELL SITE AS WELL AS THE DEEP INJECTION WELL SYSTEM AT THE SCRWTP PRIOR TO BIDDING THE PROJECT TO FAMILIARIZE THEMSELVES WITH EACH WELL AND PIPING CONFIGURATION. THE WATER/WASTEWATER GENERATED FROM THE WELL KILLING PROCESS PRIOR TO THE NEW VALVE WORK AND POST FLUSHING MUST BE RECOVERED AND DISPOSED OF, AS DIRECTED BY SCRWTP PLANT STAFF, VIA THE DEEP INJECTION WELL SYSTEM LOCATED AT THE SCRWTP.

GENERAL PROJECT DATA1. PLANS FOR THESE DRAWINGS WERE BASED ON VISUAL INSPECTION AND THE AS BUILT DRAWINGS FOR THE WELLFIELD. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND LENGTHS.2. ANY CHARACTERISTICS OR CONFLICTS IN THE DRAWINGS AND SPECIFICATIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND CLARIFICATION ISSUED BEFORE THE CONTRACTOR SUBMITS HIS BID. THE CONTRACTOR SHALL CONTACT THE ENGINEER/OWNER IMMEDIATELY IF ANY CONFLICTS ARE FOUND DURING CONSTRUCTION.3. DAMAGE TO EXISTING FACILITIES DURING CONSTRUCTION SHALL BE REPAIRED AND/OR REPLACED AT CONTRACTORS EXPENSE.4. PERFORM ALL WORK IN A SAFE MANNER, FOLLOW ALL SAFETY RULES AND GUIDELINES OF OSHA. THE CONTRACTOR IS WHOLLY RESPONSIBLE FOR ANY INJURIES OF HIS EMPLOYEES, INTRUDERS, AND ANY DAMAGE TO PRIVATE PROPERTY OR PERSONS DURING THE COURSE OF THIS PROJECT.5. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED AS RECOMMENDED BY THE MANUFACTURER.SUBMITTALS.1. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER FOR APPROVAL PRIOR TO ORDERING THE MATERIALS IF REQUIRED FOR CONSTRUCTION. NO MATERIALS SHALL BE BROUGHT ONSITE WITHOUT SHOP DRAWING APPROVAL. CUT SHEETS FOR THE MATERIALS TO BE PROVIDED BY COLLIER COUNTY ARE ATTACHED.2. CONTRACTOR SHALL EXERCISE CARE IN TRANSPORTING AND HANDLING ALL MATERIALS IN ORDER TO AVOID DAMAGE. LIFTING SHALL BE BY HOIST OR SKIDS WHEN HAND LIFTING IS NOT FEASIBLE. STORE MATERIALS AS RECOMMENDED BY THE MANUFACTURER. DAMAGED MATERIALS SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE.

BUTTERFLY VALVES1. TWENTY BUTTERFLY VALVES (6” DEZURIK HP LUG BFV 316SS) WILL BE PROVIDED BY COLLIER COUNTY AND SHALL MEET OR EXCEED THE DESIGN STRENGTH, TESTING AND PERFORMANCE REQUIREMENTS OF AWWA C504, CLASS 150. A COMPLETE PARTS LIST OF MATERIAL TO BE PROVIDED BY THE COUNTY IS ATTACHED. THE TEXT BELOW IS FOR INFORMATIONAL PURPOSES ONLY. 2. THE COUNTY SHALL PROVIDE NUTS, BOLTS, WASHERS, AND GASKETS FOR INSTALLATION OF THE BUTTERFLY VALVE AND CHECK VALVES. 3. VALVE BODY SHALL BE MECHANICAL JOINT END TYPE VALVE CONSTRUCTED OF 316 SS, PICKLED AND PASSIVIZED. 4. DISC SHALL BE ONE PIECE CAST DESIGN WITH NO EXTERNAL RIBS TRANSVERSE TO FLOW. DISC SHALL BE CAST IRON OR DUCTILE IRON.5. THE RESILIENT SEAT SHALL BE BONDED TO THE VALVE BODY AND SHALL MATE WITH THE 316 STAINLESS STEEL SURFACE.6. VALVE SHAFTS SHALL BE ONE PIECE EXTENDED COMPLETELY THROUGH THE DISC OR STUB SHAFTS EXTENDING 1½ TIMES THE SHAFT DIAMETER INTO THE DISC. VALVE SHAFT DIAMETER SHALL BE AS REQUIRED BY AWWA C504. VALVE SHAFTS SHALL BE OF 316 STAINLESS STEEL. DISC TO STEM CONNECTIONS OR TURNED DOWN PORTIONS OF THE SHAFTS SHALL BE DESIGNED TO TRANSMIT SHAFT TORQUE EQUIVALENT TO 75% OF THE REQUIRED SHAFT DIAMETER. BUSHINGS SHALL BE OF STAINLESS STEEL. SEALS MAY BE PRE-LOADED BY PACKING GLAND MECHANISM.7. MANUAL VALVE OPERATORS SHALL BE DESIGNED TO HOLD THE VALVE DISC IN ANY INTERMEDIATE POSITION BETWEEN FULLY OPENED AND FULLY CLOSED WITHOUT CREEPING OR FLUTTERING. THE OPERATOR SHALL BE CAPABLE OF TRANSMITTING SUFFICIENT TORQUE TO OPEN OR CLOSE EACH VALVE UNDER THE MOST ADVERSE OPERATING CONDITIONS. AN INDICATING ARROW SHALL BE PROVIDED TO GIVE FULL CLOSED, FULL OPEN, OR INTERMEDIATE DISC POSITION INDICATORS.8. VALVES ARE DEZURIK, PER THE COUNTY'S APPROVED PRODUCT LIST, OR EQUAL.9. THE HEIGHT OF THE VALVE SHALL CONFORM TO THE HEIGHT OF THE CONNECTING PIPE. VALVES SHALL BE SET IN A VERTICAL POSITION UNLESS OTHERWISE INDICATED ON THE DRAWINGS. STEMS SHALL NEVER BE BELOW A HORIZONTAL POSITION.10. OPEN AND CLOSE EACH VALVE OBSERVING FULL OPERATION PRIOR TO INSTALLING SUCCESSIVE LENGTHS OF PIPE.

CONTROL VALVES1. THE CONTRACTOR SHALL INSTALL A CHECK VALVE AT THE LOCATION SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. TWENTY CHECK VALVES (APCO RUBBER FLAPPER SWING 6” CHECK VALVE MODEL 100SR) WILL BE SUPPLIED BY COLLIER COUNTY. A COMPLETE PARTS LIST OF MATERIAL TO BE PROVIDED BY THE COUNTY IS ATTACHED. VALVE AND BODY INTERNAL SHALL BE SUITABLE FOR AGGRESSIVE WATER CONDITIONS WITH A HIGH SALINITY CONTENT.2. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, AND INCIDENTALS REQUIRED FOR THE PROPER COMPLETION OF THE WORK. ANY INCIDENTALS OR MISSING EQUIPMENT REQUIRED FOR A COMPLETE INSTALLATION SHALL BE PROVIDED BY THE CONTRACTOR AT NO EXTRA COST, IF NECESSARY.3. COUNTY STAFF WILL COLLECT WATER QUALITY SAMPLES FROM EACH WELL PRIOR TO AND AFTER WORK IS COMPLETED. EACH SAMPLE WILL BE ANALYZED FOR SPECIFIC CONDUCTIVITY AND TURBIDITY. EACH WELL WILL NEED TO BE FLUSHED UNTIL THE WELL HAS REACHED BACKGROUND CONDITIONS.4. THE CONTRACTOR SHALL PERFORM THE 2 DAY BAC T SAMPLING PURSUANT TO FDEP SOP.5. HYDRAULIC NON-SLAM CHECK VALVE (THE TEXT BELOW IN THIS SECTION IS FOR INFORMATIONAL PURPOSES ONLY.)6. FUNCTION: THE HYDRAULIC NON-SLAM CHECK VALVE WILL BE PROVIDED BY COLLIER COUNTY AND SHALL BE A DOUBLE CHAMBERED DESIGN, HYDRAULICALLY OPERATED, DIAPHRAGM ACTUATED CONTROL VALVE. THE DIAPHRAGM ACTUATED CONTROL VAL VE SHALL BE HYDRAULICALLY POWERED TO THE FULLY OPEN POSITION DURING SYSTEM FLOW WHEN UPSTREAM PRESSURE EXCEEDS DOWNSTREAM PRESSURE. IF PRESSURE CONDITIONS REVERSE, THE MAIN VALVE SHALL CLOSE OFF DRIP TIGHT PREVENTING BACK FLOW.7. DESCRIPTION: THE VALVE SHALL BE HYDRAULICALLY OPERATED, DIAPHRAGM ACTUATED, Y-PATTERN GLOBE STYLE. 8. VALVE BODY: THE VALVE BODY AND COVER SHALL BE CONSTRUCTED OF A HIGH STRENGTH DUCTILE IRON CONFORMING TO ASTM A536. THE VALVE SHALL BE PRESSURE RATED AT 250 PSI. THE VALVE BODY SHALL BE INTERNALLY AND EXTERNALLY COATED WITH AN NSF 61 APPROVED EPOXY POWDER- FUSION BONDED.THE VALVE STEM AND SEAT SHALL BE CONSTRUCTED OF 316 STAINLESS STEEL. ALL REPAIRS SHALL BE POSSIBLE WITHOUT REMOVING THE VALVE BODY FROM THE LINE. THE VALVE BODY SHALL HAVE INTEGRAL FLANGES, FACED AND DRILLED PER ANSI CLASS 150. THE SEAT AREA SHALL HAVE A FLOW OPENING WITHOUT STEM GUIDES, BEARINGS OR SUPPORTING RIBS.ACTUATOR: THE ACTUATOR ASSEMBLY SHALL BE DOUBLE CHAMBERED DIAPHRAGM OPERATED. THE ACTUATOR SHALL BE CAPABLE OF BEING CHANGED TO A SINGLE CHAMBER CONFIGURATION IN THE FIELD WITHOUT THE ADDITION OR SUBTRACTION OF ANY PARTITIONS OR CHAMBERS. THE VALVE STEM SHALL BE GUIDED BY A REPLACEABLE BEARING BUSHINGS TO ASSURE ALIGNMENT FOR TRUE SEAL AND CONTROL. THE DIAPHRAGM SHALL CONSIST OF NYLON FABRIC, BONDED WITH EPDM ELASTOMERS, COMPATIBLE WITH THE OPERATING FLUID. THE ENTIRE ACTUATOR ASSEMBLY CONSISTING OF THE V-PORT THROTTLING PLUG, VALVE SHAFT, BEARING, DIAPHRAGM ASSEMBLY, SEPARATING PARTITION AND TOP COVER MUST BE REMOVABLE FROM THE VALVE AS A SINGLE UNIT. THE CONTROL CHAMBER BETWEEN THE DIAPHRAGM AND THE SEPARATING PARTITION SHALL BE CAPABLE OF BEING OPEN TO OR ISOLATED FROM THE VALVE INTERNAL BODY PRESSURE. NO PISTON VALVE OPERATED ACTUATORS WILL BE ACCEPTED. THE ACTUATOR SHALL INCLUDE AN AV-PORT THROTTLING PLUG FOR SMOOTH VALVE OPERATION.9. PILOT CONTROL SYSTEM: THE CONTROL LOOP SHALL CONTAIN BOTH AN ADJUSTABLE OPENING AND CLOSING SPEED CONTROL THAT PROVIDES FOR A SMOOTH NON-SLAM CLOSING OF THE MAIN VALVE. THE SPEED CONTROLS SHALL ALL BE REPLACEABLE WITHOUT TAKING THE MAIN VALVE OUT OF SERVICE. COCK VALVES AND FILTERS MUST BE SUPPLIED IN THE CONTROL LOOP.10. TESTING: PRIOR TO SHIPMENT, THE VALVE SHALL PASS STANDARD TESTS THAT INCLUDE A PRESSURE TEST AND A FULL FUNCTION, OPERATIONAL TEST. TEST RESULTS SHALL BE SUBMITTED PRIOR TO INSTALLATION.9. WARRANTY: THE VALVE MANUFACTURER SHALL WARRANT THE VALVE TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF 1 YEAR FROM THE DATE OF SHIPMENT.11. WARRANTY: THE VALVE MANUFACTURER SHALL WARRANT THE VALVE TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FORA PERIOD OF 1 YEAR FROM THE DATE OF SHIPMENT.

PIPING ACCESSORIES1. PIPING ACCESSORIES WILL BE SUPPLIED BY COLLIER COUNTY. A COMPLETE PARTS LIST OF MATERIAL TO BE PROVIDED BY THE COUNTY IS ATTACHED. (THE TEXT BELOW IN THIS SECTION IS FOR INFORMATIONAL PURPOSES ONLY.) BOLTS AND NUTS FOR FLANGES SHALL BE TYPE 316 STAINLESS STEEL CONFORMING TO ASTM A 193, GRADE B8M, FOR BOLTS, AND ASTM A 194, GRADE SM, FOR NUTS. PROVIDE WASHER FOR EACH NUT, WASHERS SHALL BE OF SIMILAR MATERIAL AS THE NUTS. ANY INCIDENTALS OR MISSING EQUIPMENT REQUIRED FOR A COMPLETE INSTALLATION SHALL BE PROVIDED BY THE CONTRACTOR AT NO EXTRA COST, IF NECESSARY.2. COUNTY WILL PROVIDE GASKETS FOR FLANGES, AS REQUIRED. GASKETS SHALL BE COMPOSED OF NSF APPROVED MATERIAL FOR WATER SERVICE OF AMBIENT TEMPERATURE.

PRESSURE AND LEAKAGE TESTING1. PIPING SHALL BE SLOWLY FILLED WITH WATER AND ALL AIR EXPELLED. CARE SHALL BE TAKEN THAT ALL AIR VALVES ARE INSTALLED AND OPEN IN THE SECTION BEING FILLED, AND THAT THE RATE OF FILLING DOES NOT EXCEED THE VENTING CAPACITY OF THE AIR VALVES.2. APPLY HYDROSTATIC TEST PRESSURE OF 150 PSI FOR 10 MINUTES AND FOR SUCH ADDITIONAL PERIOD NECESSARY FOR THE ENGINEER TO COMPLETE THE INSPECTION OF THE LINE UNDER TEST. DO NOT EXCEED PIPE MANUFACTURER'S SUGGESTED TIME DURATION AT THE TEST PRESSURE. IF DEFECTS ARE NOTED, REPAIRS SHALL BE MADE AND THE TEST REPEATED UNTIL ALL PARTS OF THE LINE WITHSTAND THE TEST PRESSURE.3. APPLY LEAKAGE TEST PRESSURE OF 150 PSI. MAINTAIN PRESSURE AT A MAXIMUM VARIATION OF 5 PERCENT DURING THE ENTIRE LEAKAGE TESTS THE DURATION OF THE LEAKAGE TEST SHALL BE TWO HOURS MINIMUM, AND FOR SUCH ADDITIONAL TIME NECESSARY FOR THE ENGINEER TO COMPLETE INSPECTION OF THE SECTION OF LINE UNDER TESTS LEAKAGE MEASUREMENTS SHALL NOT BE STARTED UNTIL A CONSTANT TEST PRESSURE HAS BEEN ESTABLISHED.4. NO LEAKAGE IS ALLOWED IN EXPOSED PIPING, BURIED PIPING WITH FLANGED, THREADED, OR WELDED JOINTS ON THE POTABLE WATER LINES.5. ALL APPARENT LEAKS DISCOVERED WITHIN ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE OF THE WORK BY THE OWNER SHALL BE LOCATED AND REPAIRED BY CONTRACTOR, REGARDLESS OF THE TOTAL LINE LEAKAGE RATE.

SEQUENCE OF TESTING AND DISINFECTIONTHE SEQUENCE OF TESTING AND DISINFECTION SHALL BE AS FOLLOWS:1. CONDUCT PRESSURE AND LEAKAGE TESTING2. PERFORM FLUSHING3. DISINFECT THE WATER MAIN, INCLUDING VALVES AND FITTINGS4. FLUSH AFTER DISINFECTION.5. PERFORM REQUIRED BAC-T SAMPLING AND ANALYSESSITE RESTORATIONTHE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DISTURBED AREAS BACK TO ORIGINAL CONDITION.

PRODUCTION WELL KILL CALCULATIONS AND PROCEDURE1. DETERMINE THE DIAMETER OF THE WELL.2. DETERMINE THE “SHUT IN” PRESSURE OF THE WELL EITHER IN PSI OR FEET OF HEAD.3. CALCULATE THE FORCE ON THE WELLHEAD.a. INSIDE DIAMETER OF WELL CASING DIVIDED BY 2. (16” HOLE = 8)b. SQUARE THAT NUMBER. (8X8 = 64)c. MULTIPLY BY 3.14 (64 X 3.14 = 200.96)d. THE RESULT IS THE TOTAL SQUARE INCHES OF THE WELLHEAD.e. MULTIPLY THAT NUMBER BY THE “SHUT IN” PRESSURE OF THE WELL. ADD ANY ADDITIONAL AMOUNT FOR REDUCING THE WATER LEVEL BELOW GROUND. SOUTH COUNTY WTP: IT WAS DOCUMENTED THAT THE SHUT IN PRESSURE OF THE WELLS ARE APPROXIMATELY 10.82 PSI (ABOVE LAND SURFACE), AND YOU WANT TO KILL THE WELL TO 10 FEET BELOW GROUND, ADD 10 FEET OF HEAD TO YOUR CALCULATION (10' / 2.31 FEET PER POUND PRESSURE = 4.33 POUNDS ADDITIONAL PRESSURE TO REDUCE) ADD THE TWO TOGETHER (10.82+4.33 = 15.15 PSI)f. MULTIPLY THE TOTAL PRESSURE REDUCTION NEEDED BY THE SQUARE INCHES OF THE WELLHEAD FROM ABOVE.(15.15 PSI X 201.1 SQ INCHES = 3,047 POUNDS FORCE)g. THE RESULTING NUMBER IS THE THEORETICAL AMOUNT OF WEIGHTING OR “KILL” MATERIAL NEEDED TO REDUCE THE WELLHEAD PRESSURE.4. CONNECT TO THE 6‐INCH DIAMETER BLOW‐OFF PIPE WITH THE PRESSURE LINE.5. MIX CALCULATED AMOUNT OF KILL MATERIAL PLUS 20%, IN MIXING TANK. IF USING SALT, MIX WATER AND SALT INTO BRINE SLURRY.6. OPEN APPROPRIATE VALVES AND PUMP KILL SOLUTION DOWN WELL.7. CHECK PRESSURES OR WATER LEVEL IN WELL.8. MIX ANOTHER BATCH OF BRINE OR KILL SOLUTION IF NECESSARY AND REPEAT THE PROCESS.9. MONITOR WATER LEVEL IN WELL AND ADD WEIGHT MATERIAL AS NEEDED.10. ONCE ALL REPAIRS/FABRICATIONS HAVE BEEN COMPLETED, THE PRODUCTION WELL(S) WILL NEED TO BE PUMPED TO BACKGROUND CONDITIONS. ALL DEVELOPED WATER MUST BE CONTAINED AND DISPOSED OF AT AN APPROVED LOCATION.NOTE: THERE ARE SEVERAL METHODS OF DETERMINING THE DIMENSIONS OF THE WELL. THE CALCULATION USED ABOVE IS ONLY ONE OF THOSE METHODS.

THE CONTRACTOR SHALL INSTALL A BUTTERFLY VALVE AT THE LOCATION SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN.

Sheet No.

4 OF 5

4

Plan prepared by:Schlumberger Water Services USA Inc.

1567 Hayley Ln, Ste 202Fort Myers, FL 33907Ph. (239) 481-6494

Engineer CA License No. 27716William S. Manahan, P.E.

Florida Professional Engineer License No. 51423

Drawn by:

Designed by:

Checked by:

Approved by:

Scale:

WSM

WDW

RGM

WSM

NTS

Date: 11/16/2015

Project No. 0130-0563

Date:

Project Phase No. 3

EXISTING SPACER TO BEREPLACED WITH BUTTERFLY VALVE

EXISTING CHECK VALVETO BE REPLACED WITH

NEW CHECK VALVE

WELLHEAD WITH IMPROVEMENTSEXISTING WELLHEAD OVERVIEW

NEWCHECK VALVE

NEWBUTTERFLY VALVE

Well 33S

Well 16S

THIS PICTURE SHOWS THE CURRENT OR TYPICAL CONFIGURATION OF MOST OF THE WELLHEADS.THE CHECK VALVE WILL BE REPLACED AND A BUTTERFLY VALVE INSTALLED AT THE SPACER LOCATION.

THIS PICTURE SHOWS A WELLHEADWITH THE PROPOSED IMPROVEMENTS COMPLETED.

Sheet No.

5 OF 5

5

Plan prepared by:Schlumberger Water Services USA Inc.

1567 Hayley Ln, Ste 202Fort Myers, FL 33907Ph. (239) 481-6494

Engineer CA License No. 27716William S. Manahan, P.E.

Florida Professional Engineer License No. 51423

Drawn by:

Designed by:

Checked by:

Approved by:

Scale:

WSM

WDW

RGM

WSM

NTS

Date: 11/16/2015

Project No. 0130-0563

Date:

Project Phase No. 3

EXISTING SPOOL PIECE TO BEMODIFIED WITH BUTTERFLY VALVE

EXISTING CHECK VALVETO BE REPLACED WITH

NEW CHECK VALVE

EXISTING WELLHEAD OVERVIEWWELL 19

PROPOSEDCHECK VALVE

PROPOSEDBUTTERFLY VALVE

Well 19S Well 19S

EXISTING SPOOL PIECE TO BEMODIFIED WITH BUTTERFLY VALVE

EXISTING CHECK VALVETO BE REPLACED WITH

NEW CHECK VALVE

THIS WELL HAS A STAINLESS STEEL SPOOL PIECE IN LIEU OF THE SPACER.THE SPOOL PIECE WILL NEED TO BE MODIFIED TO ACCOMMODATE THE BUTTERFLY VALVE.

THIS PICTURE IS AN ALTERNATIVE VIEW OF THE WELLHEAD.

BULLETIN 100

AUGUST 2011

APCO RUBBER FLAPPER SWING CHECK VALVES

Series 100Series 100RSeries 100SRSeries 100SA

- Ductile Iron Standard 2"-24" (50-600mm)

- For water or sewage applications

- Ultra simplicity in design engineering

- Relatively no maintenance required

- Precision molded, steel reinforced rubber flapper

- Bubble tight seating

- Unrestricted full flow area

- ISO flange connections available

- Meets AWWA C508

Model 100SR

Description of Operation and MaterialsAPCO rubber flapper swing check valves are uniquely simple in design but durable for use on a variety of applications.

With only three major parts: Body, Flapper & Cover, there is relatively no maintenance. However, should maintenance be required, the flapper can be replaced in a matter of minutes. The valve body seat is on an angle of 45° to the centerline of the pipe, permitting horizontal or vertical flow up installation. With the flapper full open, there is a straight unobstructed flow passage, so all foreign matter is flushed away by the flowing medium. This eliminates clogging. Due to this unobstructed flow passage the pressure drop is considerably lower through the APCO Rubber Flapper Check than through conventional swing check valves.

Normally made of Cast or Ductile Iron, but readily supplied in Stainless Steel or Bronze, the valve can be lined or coated with various materials.

The flapper is normally Buna-N but can be compression molded from various synthetic rubbers. A steel disc for strength and a steel bar are molded inside the flapper. A hi-strength fabric is integrally molded over the disc and bar to form a flexible joint permitting millions of flexes without failure. For operation with aggressive media, Buna-N has excellent abrasion resistant qualities. When the valve is assembled the flapper is firmly clamped between body and cover. This feature eliminates problems of moving parts, shafts, pins, bearings, bushings, packings (as required in conventional check valves). Further, this flapper design eliminates jamming or sticking in the open position and the O-ring seal molded into the disc face assures positive sealing, even at lower pressures. Recommended for buried service with stainless steel cover bolts. Rated 125#/150# Class for 175 psi differential pressure. Higher pressure class available.

Backflow Device Optional Feature on 3" and LargerOften Pump Station Operators find it convenient to force open the Swing Check Valve by its outside lever, for the purpose of Backflushing, Priming Pumps, or to Drain the System. This is a dangerous procedure! The APCO Backflow Device meets OSHA requirements for safety because it is easily activated without risk of injury to operating personnel during a

backflow procedure. This Backflow Device is positive and will not slip during full backflow.

The Backflow Device can be removed for service without removing the check valve or taking the pump out of service. Size 3" and 4" (80 and 100mm) Backflow Devices are constructed of Bronze ASTM B-584 as approved by U.S. Navy for fleet service.

Should your next pump station design require a by-pass or backflow through the check valve for any reason…do it safely!

Specify APCO Series 100 Rubber Flapper Swing Check Valves with a Backflow Device.

104P3 StoryNotice there are two 4" (100mm) APCO Rubber Flapper Swing Check Valves!

Model 104 is a full size 4" (100mm) check valve for normal water service.

Model 104P3, designed specifically for raw sewage with a flow area thru the seat almost twice (23.76", 604mm) that of standard pipe (12.73", 323mm), permitting the 104P3 to pass a 3" (76mm) diameter solid as required by many states and municipalities for 4" (100mm) check valves used on sewage.

This feature is of special interest to sewage lift station designers.

Flow Control Option Need to Throttle or Shut-Off Flow?The Flow Control device is used to restrict the position of the flapper for the purpose of regulating flow into the system or to create a false head on the pump.

The device is mounted on the cover of the valve and when manually operated will prevent the flapper from fully opening. With this device, the Rubber Flapper Check Valve can be used as a stop check.

Proximity Switch Option Need a Signal That the Check Valve is Open?An inductive type Proximity Switch can be furnished mounted on the valve body with its target mounted internally on the flapper. This transmits an electrical signal indicating when the flapper is open or closed. Available on Series 100 and 100R.

© 2011 DeZURIK, Inc.2

APCO Rubber Flapper Swing Check Valves

Target Sensor

BackflowDevice

3

Standard Rubber Hardness Durometer of Flapper to be Determined by Operating Pressure.

Valve Size Operating Pressure, PSI

10 to 80 81 to 175

2" (50mm) to 8" (200mm) 45 Durometer 70 Durometer

10" (250mm) and Larger 70 Durometer

Always specify operating pressure when ordering.

Lining and Flapper Materials

Lining FlapperOperating Temperature Range

Valve Size

ºF ºC

— Buna-N -70 to 250 -57 to 121

Rubber — -40 to 180 -40 to 82

Neoprene Neoprene -40 to 250 -40 to 121

Hypalon Hypalon -40 to 195 -40 to 90

— Viton* -40 to 450 -40 to 232

Other Materials Available.

* Viton is a registered name of DuPont.

Applications:

- Raw Sewage

- Water Systems

- Industrial Wastes

- Chemical Lines

- Erosive Services

- Ash Service

- Acid Lines

- Tailings Systems

- Light Slurries

- Corrosive Services

- Leaching Lines

- Scrubbers

- Brine & Salt Water Systems

- Unique 45° Angle Seat Provides Non-Slamming Feature

- Cycle Tested Flapper

Materials of Construction:

- Cast Iron

- Ductile Iron

- Bronze

- Stainless Steel

BC

AD

FLOW

Easy Cover and Flapper Removal

EqualsFull Pipe

Area

SteelReinforced

Flapper

TightO-RingSeating

Body Plug

APCO Series 100 & 100R

Dimensions for 125#/150 Class Valves

Model Size A B C D

No. of Flange Bolts/

Hole Size

Weight(Approx. lbs/kg)

102 2" 50

8203

6152

4.75121

.62516 4 - .625

16198.6

102.5 2.5" 65

8.5216

7178

5.5140

.68817 4 - .625

16209

103 3" 80

9.5241

7.5191

6152

.7519 4 -

.62516

2110

104 4" 100

11.5292

9229

7.5191

.93824 8 - .625

163817

*104P3 4" 100

13.75349

9229

7.5191

.93824 8 -

.62516

7032

105 5" 125

13.75349

10254

8.5216

.93824 8 -

.7519

7434

106 6" 150

15381

11279

9.5241

125 8 -

.7519

10045

108 8" 200

19.5495

13.5343

11.75298

1.12529 8 -

.7519

18584

110 10" 250

24.5622

16406

14.25362

1.18830 12 - .875

22335152

112 12" 300

27.5699

19483

17432

1.2532 12 - .875

22475215

114 14" 350

31787

21533

18.75476

1.37535 12 - 1

25640290

116 16" 400

32813

23.5597

21.25540

1.43837 16 - 1

25950431

118 18" 450

36914

25635

22.75578

1.56340 16 - 1.125

291250567

120 20" 500

401016

27.5699

25635

1.68843 20 - 1.125

291550703

124 24" 600

481219

32813

29.5749

1.87548 20 - 1.25

322000907

* Will pass a 3" diameter solid. Larger sizes through 48" available on request. Higher pressure class available.

InchMillimeter

FLOW

Series 100R Rubber Lined Check ValveEngineer: Note that unlike other check valves, our Rubber Flapper Swing Check Valve is specially designed for rubber lining. Sharp corners and crevices are not present and the smooth body and cover contours readily accept lining or coating. The result after lining is a totally encapsulated valve without any exposed metal surfaces.

4

APCO Series 100SR - Spring Return Check Valve

Dimensions for 125# Class Valves

Model Size A B C D E

No. of Flange Bolts/

Hole Size

103SR 3" 80

9.5241

7.5191

6152

.7519

8203 4 - .75

19

104SR 4" 100

11.5292

9229

7.5191

.93824

8203 8 - .75

19

104P3SR 4" 100

13.75349

9229

7.5191

.93824

12.25311 8 - .75

19

105SR 5" 125

13.75349

10254

8.5216

.93824

12.25311 8 - .875

22

106SR 6" 150

15381

11279

9.5241

125

12.25311 8 - .875

22

108SR 8" 200

19.5495

13.5343

11.75298

1.12529

16406 8 - .875

22

110SR 10" 250

24.5622

16406

14.25362

1.18830

18.375467 12 - 1

25

112SR 12" 300

27.5699

19483

17432

1.2532

18.375467 12 - 1

25

114SR 14" 350

31787

21533

18.75476

1.37535

22.5572 12 - 1.125

29

116SR 16" 400

32813

23.5597

21.25540

1.43837

22.5572 16 - 1.125

29

118SR 18" 450

36914

25635

22.75578

1.56340

23584 16 - 1.25

32

120SR 20" 500

401016

27.5699

25635

1.68843

23584 20 - 1.25

32

124SR 24" 600

481219

32813

29.5749

1.87548

24.625625 20 - 1.375

35

InchMillimeter

FLOW

AD

BC

E

Spring is adjustable without shutting

down your system

APCO has manufactured Rubber Flapper Swing Check Valves (RFSCV) since 1965. We have many thousands of units in the field that have been operating successfully for decades. From time to time, engineers or end users have a difficult high head application where rapid flow reversal causes standard style Swing Check Valves to slam. The APCO 100SR was developed in 1978 to eliminate or minimize slam in these types of installations. The APCO 100SR has successfully managed surges (due to rapid flow reversal) even in tough vertical ‘flow up’ installations. See comparison graph on page 5.

The Standard Series-100 RFSCV has a 35º Disc Stroke and will close relatively quickly. This Stroke is very short compared to conventional Style Swing Check Valves which typically have 80º to 90º disc travel. When you add the spring return to the RFSCV it causes the disc to speed up or accelerate to valve closure. Having the Valve closed before reverse flow takes place can in many instances, drastically reduce or even eliminate valve slam.*

Simplified Spring design also available. 100SA

Position Disc Indicator also available on all Rubber Flapper Check Valve Series

5

Time/Seconds

Po

un

ds

per

Sq

uar

e In

ch

Pressure Rise in PSIG.BLUE = without Spring ReturnBLACK = with Spring Return

Pump Stopped

Valve Closed

Comparison GraphComparison Graph

This graph compares the closing characteristics of the check valve with and without the spring assisted closure. The installation is vertical “flow up” and the power failure simulation for the test is identical. The pressure rise (blue line) generated from the valve closure without the spring assist is 120 psi. The pressure rise (black line) with the spring assisted closure is only 23 psi. This represents a 97 psi reduction in the pressure surge. Also, subsequent wave patterns are more subdued and rounded. On site closure noise (valve slam) and pipe displacement disappeared with the APCO 100SR.

The PDI is mounted to the cover and clearly identifies the position of the flapper.

APCO, the originator of the Spring Return Rubber Flapper Swing Check Valve.Position Disc Indicator (PDI) Available Sizes 4" to 24"

6

SpecificationsSeries 100 Rubber Flapper Swing Check ValveThe Rubber Flapper Swing Check Valve shall have a heavily constructed cast or ductile iron body and cover. The body shall be long pattern design (not wafer) with integrally cast-on end flanges. The flapper shall be Buna-N having an O-ring seating edge and be internally reinforced with steel.

Flapper to be captured between the body and the body cover in a manner to permit the flapper to flex from closed to full open position. Flapper shall be easily removed without the need to remove the valve from line. Check Valves to have full pipe size flow area. Seating surface to be on a 45° angle requiring the flapper to travel only 35° from closed to full open position for minimum head loss, and non-slam closure characteristics.

Buna-N flapper which creates an elastic spring effect to assist the flapper to close against a slight head to prevent or minimize slamming.

Valve designed for 175 psi differential pressure for water, sewage, oil or gas (higher pressures available). The valve shall be suitable for buried service, in which case, stainless cover bolts must be furnished.

When necessary to prime or backflush a clogged pump, an external backflow device can be furnished— sizes 3" (80mm) and larger.

Cast iron ASTM A126 GR.B Bronze ASTM 584 Body & cover Stainless steel ASTM A296 or 351 Ductile iron (Standard 2"-24")(50-600mm) ASTM A536 Gr.65-45-12 Flapper Buna-N or other elastomers Exterior paint Universal Metal Primer FDA approved for potable water contact

*Bronze components meet current lead-free requirements.

Series 100R Rubber Flapper Swing Check ValveThe Rubber Flapper Swing Check Valve shall have a heavily constructed ductile iron body and cover. The body shall be long pattern design (not wafer), with integrally cast-on end flanges. The flapper shall be Buna-N (or other elastomers) having an O-ring seating edge and be internally reinforced with steel.

The body and cover shall be lined with 1/8" (3mm) thick natural rubber. The lining shall be autoclaved to the body and cover and cured to 55 durometer shore A ± 5. the lining shall be tested in conformance with ASTM d573.

Flapper to be captured between the body and the body cover in a manner to permit the flapper to flex from closed to full open position during flow through the valve. Flapper shall be easily removed without need to remove valve from line. Check Valves to have full pipe size flow area. Seating surface to be on a 45° angle requiring the flapper to travel only 35° from closed to full open position.

Buna-N flapper (hi-strength coated fabric) which creates an elastic spring effect, molded internally to assist the flapper to close against a slight head to prevent slamming.

When necessary to prime or backflush a clogged pump, an external backflow device can be furnished— sizes 3" (80mm) and larger.

Materials of construction shall be certified in writing to conform to ASTM specifications as follows:

Body & cover Cast or Ductile Iron (2"-24")(50-600mm) ASTM A536 Gr.65-45-12 Flapper Buna-N Lining Natural Rubber Exterior paint Universal Metal Primer FDA approved for potable water contact

7

Flow Tests Conducted September 1975Colorado State UniversityComplete Test Report Available Upon Request

0 1 2 3 4 5 6 7 8 9 10.8

.7

.6

.5

.4

.3

.2

.1

00 5 10 15 20 25 30

8

7

6

5

4

3

2

1

0

Velocity in Pipe, fps.

Velocity in Pipe, fps.

Pre

ssu

re L

oss

, psi

.

Pre

ssu

re L

oss

, psi

.

12" Rubber FlapperSwing Check Valve

Tests indicate losses are slightly higher for smaller sizes and lower for larger

sizes than shown here

Actual Test Points

Pressure head to unseat flapper with downstream pipe full (discharge side). Flapper submerged and bouyant

Pressure head to unseat flapper, downstream pipe empty

DeZURIK, Inc. reserves the right to incorporate our latest design and material changes without notice or obligation. Design features, materials of construction and dimensional data, as described in this bulletin, are provided for your information only

and should not be relied upon unless confirmed in writing by DeZURIK, Inc. Certified drawings are available upon request.

Printed in the U.S.A.

250 Riverside Ave. N. Sartell, Minnesota 56377 • Phone: 320-259-2000 • Fax: 320-259-2227

For information about our worldwide locations, approvals, certifications and local representative:Web Site: www.dezurik.com E-Mail: [email protected]

Sales and Service