COAXIAL BARRIER SEAL OPERATED AS A SEPARATION SEAL IN A PIPELINE COMPRESSOR 41 st Turbomachinery Symposium Henk Blekkenhorst Huub de Bruijn H d f th C S i Henk Blekkenhorst Senior Compressor Engineer Siemens Energy Service Hengelo, Netherlands Head of the Compressor Service Product Management Department Siemens Energy Service Hengelo, Netherlands Christian Bonfert Senior Expert Compressor Seals and Systems EagleBurgmann Germany GmbH & Co. KG Wolfratshausen, Germany Ferdinand Werdecker Head of Engineering Compressor Seals EagleBurgmann Germany GmbH & Co. KG Wolfratshausen, Germany 1

Upload: others

Post on 07-Apr-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

COAXIAL BARRIER SEAL OPERATED AS A SEPARATION SEAL IN A PIPELINE COMPRESSOR

41st Turbomachinery Symposium

Henk Blekkenhorst Huub de BruijnH d f th C S iHenk Blekkenhorst

Senior Compressor EngineerSiemens Energy Service

Hengelo, Netherlands

Head of the Compressor Service Product Management Department

Siemens Energy ServiceHengelo, Netherlands

Christian BonfertSenior Expert Compressor Seals and Systems

EagleBurgmann Germany GmbH & Co. KGWolfratshausen, Germany

Ferdinand WerdeckerHead of Engineering Compressor Seals

EagleBurgmann Germany GmbH & Co. KGWolfratshausen, Germany

1

Content

Purpose of modificationThis presentation will provide

details of the first application of a Coaxial Barrier Seal in a pipeline

Preparation / Qualification

Installation

Coaxial Barrier Seal in a pipeline compressor

Installation

Commissioning

Evaluation

Conclusion

2

Purpose of Project

Optimize compressor sealing system design for safe and reliableOptimize compressor sealing system design for safe and reliable operation with lower emissions

I d ti b t l b il dImproved separation between lube oil and process gas

Simplified seal arrangement

Reduced N2 consumption

Safe and secure gas seal monitoring system

Increased gas seal life time prolonged MTBF / MTBM

3

Qualification tests of Coaxial Barrier Seal (prototype testing)

B i S l S li Sh T S UBarrier Seal Supplier Shop Test Set Up

4

Qualification tests of Coaxial Barrier Seal

Static test – gas separation

Normal operation – leakage rates

Low backpressure leakage p g

High backpressure leakage

Gas consumption at high vent back pressure (with PDCV)

Simulation closed supply lineSimulation closed supply line

Long term tests with permanent pressurization of vent cavity

5

Qualification tests of Coaxial Barrier Seal

Qualification tests (static test)Qualification tests (static test)

Supply pressure

Leakage flowVent pressureLeakage flow

6Time

Qualification tests of Coaxial Barrier Seal

Qualification tests (normal operation)Qualification tests (normal operation)Supply pressureSpeed

Leakage flow

Leakage flow

Seal facetemperatures

7Time

Qualification tests of Coaxial Barrier Seal

Qualification tests (low back pressure/axial shift)Qualification tests (low back pressure/axial shift)

Supply pressure

Leakage flow

Leakage flow

8Time

Qualification tests of Coaxial Barrier Seal)

Qualification tests (high back pressure/trip)Qualification tests (high back pressure/trip)

Speed Leakage flow

Leakage flow

Seal face Vent pressureSeal facetemperatures

Vent pressure

Supply pressure

9Time

Qualification tests of Coaxial Barrier Seal

Qualification tests (N supply failure)Qualification tests (N2 supply failure)

Speed

Seal facetemperatures

Supply pressure

Leakage flowLeakage flow

10Time

Qualification tests of Coaxial Barrier Seal - Results

Visual inspection of seal faces (standard at seals suppliers) didn’t showed contact marks – like new

Leakage rates during normal operation was within the specificationp

Leakage rates at upset operating conditions even lower than expectedexpected

Stable operation behavior of the coaxial barrier seal during all tests has been observedtests has been observed

RESULTED IN DELIVERY AND INSTALLATION

11

RELEASE OF THE SEAL

Installation

Application: Compressor Station

Location: Nether Kellet, Lancashire, United Kingdom

End User: National Grid Transco plc.

12

Courtesy of Official National Grid Website

Installation

Compressor Set UpCo p esso Set Up

Barrier Seal t pe CBStype CBS

Main Seal type DGS

13

yp

* Comparison at set process conditions

Installation

Proposed modificationsto P&ID includeto P&ID include

- Low and high alarm / trip coaxialbarriersealbarrierseal

- Flow measurement new Coaxial Barrier Sealnew Coaxial Barrier Seal

- PCV N2 supply new internals

- New orifice N2 supply

14

- PALL primary vent

Evaluation – Operation after start up with new barrier seal

DCS Overview :At normal load

N2 leakage rate 6 Nl/min

15

Evaluation – Operation after start up with new barrier seal

DCS Overview :At maximum load

N2 leakage rate 8 Nl/min

16

Evaluation – End User feedback

Operating statusEnd User quote

”I l h i f hp g

Start up on 2011-09-08

”In general, the operation of the CBS is already proving to be a

success. There has been a lot of stop – start operation, including ESD t i d it h d d th

Status on 2012-02-20- 1,269 operating hours

65 St t

ESD trips and it has endured the harshest of tests; performance

testing of the compressor during which time the actual S li l tt d Th- 65 Starts

- 19 Running Trips- 11 Starting Trips

Surge line was plotted. There has not been one issue with its operation since installation.”

E d U t- 35 Normal Stops End User unquote

17

Conclusion

UPGRADE JOB TO COAXIAL BARRIER SEAL WAS A FULL SUCCESS STORY!

Main challenges on this pilot projectg p p j

Understanding the components to be improved on the existing sealing systemsealing system

Providing a technology which is able to eliminate the existing limitationslimitations

Implementation of new technology in an existing system

Coordination of the work with all involved parties

18

RESULTED IN THE FIRST RUNNING REFERENCE OF THE NEW COAXIAL BARRIER SEAL TYPE