Page 1: CO and Diode Laser Platform: 2light-sys.com/images/Broshuri/SmartXide.pdfTechnical Specifications of CO 2 Sources Models C40* C60 and C60H C80 and C80H Type of Laser CO 2 RF - PSD®

CO2 and Diode Laser Platform:Unique, Versatile, Multidisciplinary

SMARTXIDE2

MEDICINE AND AESTHETICS - V2LR SURGERY - DENTISTRY

SM

ARTX

IDE

2

Page 2: CO and Diode Laser Platform: 2light-sys.com/images/Broshuri/SmartXide.pdfTechnical Specifications of CO 2 Sources Models C40* C60 and C60H C80 and C80H Type of Laser CO 2 RF - PSD®

10

Dedicated Pulse Shape for each Application DEKA presents the first and only CO2 laser with exclusive PSD® technology granting the choice of the optimal pulse shape: S-pulse, D-pulse, H-pulse, U-pulse and CW mode. The operator can choose the most suitable pulse mode for each treatment, obtaining maximum benefit with minimum invasiveness and the best possible results.

CO2 LASER SOURCE WITH PSD® TECHNOLOGY

SMARTXIDE2

The SmartXide2 system brings together scientific DEKA know-how and technological innovation. The multidisciplinary and multifunctional features of DEKA’s new SmartXide2 system make it an authentic novelty in the world of laser platforms by combining CO2 and diode lasers in one system. SmartXide2 comes fully equipped with a range of features and accessories that make it equally suitable for use in:

• Dermatology, Plastic Surgery and Aesthetics

• ENT

• Gynaecology

• V2LR (Vulvo-Vaginal Laser Reshaping)

• Neurosurgery

• General Surgery

• Dentistry

Each system is equipped with a complete multidisciplinary database and dedicated handpieces, as well as optional accessories such as scanners and micromanipulator designed to enhance and optimize the operative performances.

SMARTXIDE2: SCIENTIFIC KNOWLEDGE AND TECHNOLOGICAL INNOVATION

SmartXide2 is the only CO2 laser system offering the option of incorporating a diode laser module, even through an after-sales upgrade.Diode lasers are well known and extensively used in many medical fields thanks to user-friendliness and advantages of fibre optic beam delivery. Diode laser is available with 2 wavelengths (940 nm or 980 nm) and 2 maximum powers (30 W and 50 W). A wide range of optical fibres from 200 to 600 microns, single use or 10-time sterilisable can be chosen.

DIODE LASER

Pow

er

ms

DEKAPulse (DP)

Pulse Duration

kW Ablation

Thermal Effect

µs

UltraPulse (UP) kW

Pow

er

Ablation

Pulse Duration

Pow

er

ms

SmartPulse (SP) kW

Ablation

Thermal Effect

Pulse Duration

µs

HighPulse (HP)

Pow

er

Ablation

Pulse Duration

kW

Thermal EffectAblation

Power Dwell

Not to scale

Page 3: CO and Diode Laser Platform: 2light-sys.com/images/Broshuri/SmartXide.pdfTechnical Specifications of CO 2 Sources Models C40* C60 and C60H C80 and C80H Type of Laser CO 2 RF - PSD®

Technical Specifications of CO2 Sources

Models C40* C60 and C60H C80 and C80HType of Laser CO2 RF - PSD®

Wavelength 10.6 µm

Emission Beam TEM00

Emission Modes CW - SP - DP - HP CW - SP - DP - UP - HP

CW Power From 0.5 to 40 W From 0.5 to 60 W From 0.5 to 70 W

SP Power From 0.1 to 12 W From 0.1 to 15 W From 0.1 to 15 W

DP Power From 0.2 to 12 W From 0.2 to 15 W From 0.2 to 15 W

HP Power From 0.1 to 4 W From 0.1 to 8 W From 0.1 to 15 W

UP Power N/A From 0.5 to 60 W From 0.5 to 80 W

Emission Time From 0.01 to 0.9 seconds.

Delay Emission Time From 0.3 to 5 seconds.

Beam Delivery 7 Mirrors articulated arm with counterweight

Aiming BeamLaser diode @ 635 nm - 4 mW

Adjustable intensity from 2% to 100% Aiming light OFF or Diode OFF while lasering (DOWL).

Internal DatabaseAbout 150 factory stored protocols, upgradable by USB.

Possibility of storing unlimited number of custom user’s protocols.

Control Panel LCD Colour Touch Screen Touch 10.4”.

Electrical Requirements

From 100 to 120 Vac - 50/60 Hz From 220 to 230 Vac 50 Hz - 1,600 VA

Dimensions** and Weight

162 (H) x 59 (W) x 56 (D) cm - 95 kg for C40, C60 and C80.192 (H) x 59 (W) x 56 (D) cm - 100 kg for C60H and C80H.

63.8” (H) x 23.2” (W) x 22.0” (D) 267 lb for C40, C60 and C80.

75.6” (H) x 23.2” (W) x 22.0” (D) 281 lb for C60H and C80H.

Application FieldsDERMATOLOGY AND PLASTIC SURGERY, V2LR, AESTHETICS, ENT, GYNAECOLOGY, DENTISTRY,

NEUROSURGERY, GENERAL SURGERY

* For model C40 the upgrade to C60 is available. ** Height with folded articulated arm.

Technical Specifications of Integrated Diode Source (Optional. Also available as upgrade)Wavelength 940 nm or 980 nmCW Power 30 W 50 WOperating Modes

CW and PW

Exposure Modes

Continuous, single pulse, burst or repeated burst

Emission time in PW (Ton)

From 5 ms to 2,000 ms

Delay Emission Time in PW (Toff)

From 5 ms to 2,000 ms

Burst pulses in PW

From 2 to 50

Delay between bursts

From 0.5 s to 5 s

Beam DeliveryOptical Fibers of 200 µm, 300 µm, 400 µm, 500 µm and 600 µm, single use or 10 times sterilisable, with chip; SMA 905 connector.

Application Fields

ENT, MEDICINE AND AESTHETICS, DENTISTRY, GYNAECOLOGY.

H Model

Page 4: CO and Diode Laser Platform: 2light-sys.com/images/Broshuri/SmartXide.pdfTechnical Specifications of CO 2 Sources Models C40* C60 and C60H C80 and C80H Type of Laser CO 2 RF - PSD®

10HiScan DOT/RF is an innovative and exclusive scanning system developed for aesthetic treatments and Dermatology. It introduces for the very first time the combined action of CO2 laser and bipolar RF. The synergy between the two energies allows the HiScan DOT/RF to selectively reach all the skin layers. This generates a perfectly controlled heating of both the surface tissues and the deeper layers, with a rapid and efficacious action that gives excellent results with quicker recovery time and less downtime with enormous benefits to the patient.

HISCAN DOT/RF: INNOVATIVE COMBINED ACTION

HiScan DOT/RF Scanner System

Max Scanning Area 15 x 15 mm

Dwell Time From 100 µs to 2,000 µs, steps of 100 µs

DOT Spacing From 0 to 2,000 μm, steps of 50 µm

Scanning ShapesDOT, Line, Triangle, Parallelogram,Exagon, Square

SmartStack From 1 to 5

RF Power From 5 to 50 W

RF Dwell Time From 0.5 to 10 seconds

Emission ModesSP, DP, HP* (DOT Fractional Scanning Mode)CW (Standard Scanning Mode)

Application FieldsAESTHETICS, DERMATOLOGY AND PLASTIC SURGERY

ApplicationsFractional Skin Resurfacing (DOT Therapy), “DOT Therapy + RF” Combined Treatment, Tightening, Traditional Skin Resurfacing.

* Not available for C40 model.

Page 5: CO and Diode Laser Platform: 2light-sys.com/images/Broshuri/SmartXide.pdfTechnical Specifications of CO 2 Sources Models C40* C60 and C60H C80 and C80H Type of Laser CO 2 RF - PSD®

10With the introduction of fractional CO2 laser technology, called V2LR procedures, DEKA has given a new boost to the development in the treatment of the female genital apparatus. As part of this procedures, MonaLisa Touch® improves and replaces the most common techniques for treating vaginal atrophy, but it is also effective in treating vaginal laxity, usually referred as “wide vagina”. When inserted in the vagina, using special probes of the HiScan V2LR scanning system, the CO2 laser acts directly on the vaginal mucosa inducing collagen regeneration by delivering energy pulses through the exclusive DEKA DOT Therapy. Results on vagina walls are immediate, restablishing tone, trophism and elasticity.

HISCAN V2LR (VULVO-VAGINAL LASER RESHAPING) : A NEW APPROACH TO VAGINAL ATROPHY

HiScan V2LR (Vulvo-Vaginal Laser Reshaping) Scanner System

Max Scanning Area Square 8 x 8 mm (for single-angle and vulvar probes)

Dwell Time From 100 to 2,000 µs

DOT Spacing From 0 to 2,000 µm

SmartStack Level From 1 to 5

Scanning Methods Normal, Interlaced, SmartTrack.

Emission Modes SP - DP - HP*

AccessoriesVaginal Probes: 360° full-angle, 90° single-angle “closed” (optional), 90° single-angle “open” (optional). Vulvar Probe.

Application Field V2LR (Vulvo-Vaginal Laser Reshaping)

ApplicationsAtrophic Vaginitis, Vaginal Laxity, Stress Urinary Incontinence, Postpartum Perineal Trauma, Genital Functional and Cosmetic Laser Surgery

* Not available for C40 model.

®

www.monalisatouch.com

Page 6: CO and Diode Laser Platform: 2light-sys.com/images/Broshuri/SmartXide.pdfTechnical Specifications of CO 2 Sources Models C40* C60 and C60H C80 and C80H Type of Laser CO 2 RF - PSD®

10EasySpot Hybrid offers exclusive technical advantages in microscopic surgery granting full control in areas requiring extreme precision and utmost accuracy. Combining holographic lens and high reflectivity mirrors hybrid technology produces micro spots and the largest scanning figures in the market. The main scanning functions are microswitch-controlled by the joystick allowing the surgeon to operate without ever taking their eyes off the microscope.

EASYSPOT HYBRID MICROMANIPULATOR: THE NEW GOLD STANDARD IN MICROSURGERY

Hybrid EasySpot Micromanipulator

Optical Technology Hybrid - Holographic lens and mirrors.

Spot Size Min 140 μm - Max 4.5 mm

Operative Field @ 400 mm EFL Min 20x18 mm - Max 55x40 mm

Joystick Controls Rotation and ablation shape dimensions, Scan-ON/Scan-OFF, Centering fine tuning

Application Fields ENT, GYNAECOLOGY, NEUROSURGERY

Adaptable to the most common surgical microscopes and colposcopes

HISCAN Surgical scanning system coupled with EasySpot Hybrid micromanipulator.

Page 7: CO and Diode Laser Platform: 2light-sys.com/images/Broshuri/SmartXide.pdfTechnical Specifications of CO 2 Sources Models C40* C60 and C60H C80 and C80H Type of Laser CO 2 RF - PSD®

10HiScan Surgical Scanner System

Max Scanning Area

6.3 mm x 6.3 mm @ 400 mm EFL

Dwell Time From 100 μs to 45 ms

Selectable Ablation Depth From 0.2 to 2 mm

Scanning Modes Power Mode and Depth Mode

Scanning ShapesPoint, Line, Arcs of circle up to complete circle, Spiral, Clover, Hexagon (progressive and interlaced scanning).

Emission Modes CW - UP

Application Fields ENT, GYNAECOLOGY, NEUROSURGERY

HiScan Surgical is a double-galvanometer system patented by DEKA. It allows the robotic technology use in microsurgery. The laser beam focused by the zoom of the hybrid micromanipulator in spots of few microns is rapidly moved offering:

• optimal scanning figures for cutting and ablation of tissues.• minimum lateral thermal damage to tissues;• selection of the ablation depth of each single scan (depth mode); • reduced learning curve.

HISCAN SURGICAL: NEW ADVANCEMENT IN SCANNER-ASSISTED MICROSURGERY IN ENT, NEUROSURGERY AND COLPOSCOPIC GYNAECOLOGY

EndoScan ultra miniaturised scanning system, patented and exclusive to DEKA, can be used coupled with handpieces as well as laparoscopes and surgical micromanipulators.

ENDOSCAN: NEW HORIZONS IN LAPAROSCOPIC GYNAECOLOGICAL SURGERY AND GENERAL SURGERY

EndoScan Scanner System

Max Scanning Size

5 mm @ 300 mm EFL ; 6.3 mm @ 400 mm

Dwell Time From 100 μs to 1,000 μs

Scanning Shapes Cut Mode (Point), Circle, Clover.

Emission Modes CW - UP

Application Fields ENT, GYNAECOLOGY, GENERAL SURGERY

Top image, Endoscan scanner system. Bottom image Endoscan coupled with surgical laparoscopes.

Page 8: CO and Diode Laser Platform: 2light-sys.com/images/Broshuri/SmartXide.pdfTechnical Specifications of CO 2 Sources Models C40* C60 and C60H C80 and C80H Type of Laser CO 2 RF - PSD®

MEDICINE AND AESTHETICS - ENT - GYNAECOLOGY DERMATOLOGY AND PLASTIC SURGERY - V2LRNEUROSURGERY - GENERAL SURGERY - DENTISTRY

Dealer stamp

C40

C60

- C60

H

C80 -

C80

H

Diod

e 30

W

Diod

e 50

W

Mic

ro H

ybri

d

HiS

can

DO

T/RF

HiS

can

Surg

HiS

can

V2 LR

Endo

Sca

n

Dermatology and Aesthetics

Pharyngeal ENT

Laryngeal ENT

Ear ENT

Nose ENT

Endoscopic Gynaecology

Colposcopic Gynaecology

V2LR - MonaLisa Touch®

Dentistry

Top choice Minimum choice Possible

The SmartXide2 system also comprises a wide range

of specific handpieces for the various sectors of

application: Aesthetic, Dermatolgy, ENT,

Gynaecology, V2LR, Neurosurgery,

General Surgery and Dentistry.

SMARTXIDE2 : SPECIFIC HANDPIECES FOR EACH SYSTEM

VISIBLE AND INVISIBLE LASER RADIATIONAVOID EYE OR SKIN EXPOSURE TODIRECT OR SCATTERED RADIATION

CLASS 4 LASER PRODUCT

Max. diode laser power @ 980±10nm: 50WMax. pilot laser power @ 630÷670nm: 3mW

Classi�ed by IEC 60825-1 (2007-03)

VISIBLE AND INVISIBLE LASER RADIATIONAVOID EYE OR SKIN EXPOSURE TODIRECT OR SCATTERED RADIATION

CLASS 4 LASER PRODUCTMax. CO2 laser power @ 10.6µm: 80W

Max. pulse length: 80msMax. pilot laser power @ 630÷670nm: 5mW

Classi ed by IEC 60825-1 (2007-03)

DEKA M.E.L.A. s.r.l. - All rights reserved - In order to improve its products the company reserves the right to modify these specifications without prior notice.Document Reserved for Health Professionals Only.

This brochure is not intended for the market of USA.

Follow us on

© D

EK

A 0

03-0

125-

10-0

20 R

ev.7

.2

www.dekalaser.com

DEKA M.E.L.A. s.r.l.Via Baldanzese,17 - 50041 Calenzano (FI) - Italy

Tel. +39 055 8874942 - Fax +39 055 8832884

DEKA The Code of ExcellenceA spin-off of the El.En. Group, DEKA is a world-class leader in the design and manufacture of lasers and light sources for applications in the medical field. DEKA markets its devices in more than 80 countries throughout an extensive network of international distributors as well as direct offices in Italy, France, Germany, Japan and USA. Excellence is the hallmark of DEKA’s experience and recognition garnered in the sphere of R&D in over thirty years of activity. Quality, innovation and technological excellence place DEKA and its products in a unique and distinguished position in the global arena. DEKA manufactures laser devices in compliance with the specifications of Directive 93/42/EEC and its quality assurance system, certified by is in accordance with the ISO 9001 and ISO 13485 standards.