client: jt + gl project: proposed alterations + …
TRANSCRIPT
DWG NO.
TP.00
TP.01
TP.02
TP.03
TP.04
TP.05
TP.06
TP.07
TP.08
TP.09
TP.10
TP.11
TP.12
DRAWING TITLE
COVER PAGE, DRAWING REGISTER + SITE CONTEXT PLAN
EXISTING SITE PLAN
EXISTING FLOOR PLAN
EXISTING ROOF PLAN
EXISTING ELEVATIONS
EXISTING ELEVATIONS
DEMOLITION PLAN
PROPOSED SITE PLAN
PROPOSED GROUND FLOOR PLAN
PROPOSED FIRST FLOOR PLAN
PROPOSED ROOF PLAN
PROPOSED ELEVATIONS
PROPOSED ELEVATIONS
REVISION
-
-
-
-
-
-
-
-
-
-
-
-
-
DATE
20.08.2021
20.08.2021
20.08.2021
20.08.2021
20.08.2021
20.08.2021
20.08.2021
20.08.2021
20.08.2021
20.08.2021
20.08.2021
20.08.2021
20.08.2021
TP.00DWG NO:
REV:SCALEN/ADATE
-
PROJECT NO.
COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
CLIENT: JT + GL
PROJECT: PROPOSED ALTERATIONS + ADDITIONS
ADDRESS: 8 CHESHUNT STREET, POINT LONSDALE, 3225
DRAWING REGISTER
1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE
2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.
3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.
DRAWINGCOVER PAGE, DRAWING TRANSMITTAL + SITE CONTEXT PLANPROJECT
CLIENT
DRAFT ONLY. NOT FOR CONSTRUCTION.
2021_038 CHESHUNT STREET, POINT LONSDALE
JT + GL
20.08.2021
N
D
1 SITE CONTEXT PLAN
A
C
CHESHUNT STREET
CHESHUNT STREET
POIN
T LO
NSDA
LE R
OAD
POIN
T LO
NSDA
LE S
HOPS
KIRK ROAD
A No. 8 CHESHUNT
No.8
No.6
No.10
B
B No. 8 CHESHUNT
C No. 10 CHESHUNT
D No. 6 CHESHUNT
LEGENDACU AIR-CONDITIONINGEXTERNAL UNITCP COMMUNICATIONSPITDR DRAINHWex HOT WATERUNIT EXISTING
EM ELECTRICAL METEREP ELECTRICAL POLEEPt ELECTRICAL PITEOH ELECTRICALOVERHEAD LINEFFLx FINISHED FLOORLEVEL EXISTINGFFL FINISHED FLOOR
LEVELGM GAS METERHP HYDRONIC HEATINGPANELHW HABITABLE WINDOWHWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE
WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOTZONET.01 TREE No.1TP TELSTRA PIT
TPZ TREE PROTECTIONZONEWM WATER METERWT WATER TAP
MATERIAL LEGEND
BRK1 BRICKWORK- DARK
TIM1 TIMBER CLADDING
WBD WEATHERBOARD- EXISTING
FCS1 FIBRE CEMENT SHEET AND BATTENS- EXISTING
FCS2 JAMES HARDIE SCYON STRIA CLADDING- WHITE PAINT FINISH- HORIZONTAL
FCS3 JAMES HARDIE SCYON STRIA CLADDING- CHARCOAL PAINT FINISH- VERTICAL
+ 6.09
+ 6.12
+ 6.20
+ 6.33
+ 6.40
+ 6.22
+ 5.80
+ 6.00
+ 5.60
+ 5.40
+ 5.05
+ 5.20
+ 4.86
+ 5.40
+ 5.60
+ 5.80
+ 6.00
+ 6.20
+ 4.89
+ 6.56
+ 5.32
EXISTING AREA ANALYSIS
SITE AREA= 613m²
SITE COVERAGE= 228m²(roofed area)
PERCENTAGE= 37%*should not exceed 40% DD04
GARDEN AREA= 315m²PERCENTAGE= 51%*Minimum 30% required- GRZ1
PERMEABLE AREA= 363m²PERCENTAGE= 59%*Minimum 30% required- DD04
DWG NO:
REV:SCALE1:200 @ A3DATE
-
PROJECT NO.2021_03
COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
DRAFT ONLY. NOT FOR CONSTRUCTION.1. BUILDER TO CHECK ALL DIMENSIONS BEFORE
COMMENCING WORKS ON SITE2. BUILDER TO REFER ANY DESCREPANCIES TO
THE ARCHITECT FOR CLARIFICATION.3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.
DRAWINGEXISTING SITE PLANPROJECT8 CHESHUNT STREET, POINT LONSDALE
CLIENT
20.08.2021
TP.01
8 CHESHUNTSTREET
BOUNDARY
BOUN
DARY BO
UNDA
RY
BOUNDARY
EM GM
LEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
WM
EP
GRAVEL CROSSOVER
GRAVEL DRIVEWAY
40.64205°00'
FENCE
40.64205°00'
No.1 ALBERT STREET- SINGLE STOREY BRICKBUILDING METAL ROOF- CHURCH HALL
No.6 CHESHUNT STREETDOUBLE STOREY TIMBERCLAD DWELLINGMETAL ROOF
No.10 CHESHUNT STREETDOUBLE STOREY LIGHTWEIGHTCLAD DWELLINGMETAL ROOF
CP
15.0
929
5°00
'
2.2 HIGH PALING FENCE
1.6
HIGH
PAL
ING
FENC
E15
.09
115°
00'
HEDGE
EOH
EOH
2.2 HIGH PALING FENCE WITH 0.5 SCREEN
T.01
T.02
T.03
T.04
T.05
T.06T.07T.08T.09T.10T.11
T.12T.13T.14T.15T.16
T.17T.18T.19
T.20T.21T.22
T.23
T.24
T.25
SRZTPZ
SRZ
TPZ
N
HW HW NHW NHW
HW HW
HW
NHW
NHW NHW NHW
POOL
CHES
HUNT
STR
EET
JT + GL
+ 6.09
+ 6.12
+ 6.20
+ 6.33
+ 6.40
+ 6.22
+ 5.80
+ 6.00
+ 5.60
+ 5.40
+ 5.20
+ 5.40
+ 5.60
+ 5.80
+ 6.00
+ 6.20
+ 6.56
1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE
2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.
3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL. TP.02
DWG NO:
REV:SCALE1:100 @ A3DATE
-
PROJECT NO.
DRAWING
PROJECT
CLIENTCOMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
DRAFT ONLY. NOT FOR CONSTRUCTION.EXISTING GROUND FLOOR PLAN
2021_038 CHESHUNT STREET, POINT LONSDALE
20.08.2021
LIVINGTIMex
BED 1TIMex
BED 2TIMex
CH 3035 CH 3035
CH 4380
CH 3050
HPexHPex
SLex SLex
BED 3CPTex
CH 2580
BED 4CPTex
CH 2580
WCLAMex
BATHLAMex
SHRLAMex
ENSLAMex
CH 2380
KITCHENLAMex
CH 2580
CH 2
810
CH 2
550
CH 2580
CH 2580
MH
1
2
3
4
EM
SIDE GATE
GM
HPex
HPex
HPex
HPex
HPex
DININGTIMex
HWS
BRKex
900mm
1500mmSIDE GATE
DR
DR
BOUNDARY
BOUN
DARY
FIRE
PLAC
E AN
D CH
IMNE
Y
BOUNDARY
SLex
FFLx 6.13
FENC
E
BASIC DETAIL SHOWN OF TWO STOREYBRICK AND WEATHERBOARD STRUCTURE
PROPOSED TO BE DEMOLISHED.
DETACHED DWELLING CONSISTS OF ABEDROOM, BATHROOM, KITCHEN, LIVING,
LAUNDRY AND STORAGE
CUBBY
FENCE
FENCE
T.06
T.08T.09T.10T.11T.12T.13T.14
T.15T.16
T.17T.18T.19
T.20T.21T.22
T.25
T.01
T.02
T.03
T.04
T.07
T.05
40.64205°00'
40.64205°00'
15.0
911
5°00
'
SRZ
TPZ
SRZ
TPZ
N
13700
1400
EXIS
TING
- NOM
INAL
HW HW NHW NHW
HW
HW
NHW
NHW NHW NHW
HW
EXISTING- NOMINAL
3815
.00
EXIS
TING
- NOM
INAL
8890.01
1182
9.53
JT + GLLEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
+ 6.09
+ 6.12
+ 6.20
+ 6.33
+ 6.40
+ 6.22
+ 5.80
+ 6.00
+ 5.60
+ 5.40
+ 5.40
+ 5.60
+ 5.80
+ 6.00
+ 6.20
+ 6.56
TP.03DWG NO:
REV:SCALE1:100 @ A3DATE
-
PROJECT NO.
COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
20.08.2021
1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE
2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.
3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.
DRAWINGEXISTING ROOF PLANPROJECT
CLIENT
DRAFT ONLY. NOT FOR CONSTRUCTION.
2021_038 CHESHUNT STREET, POINT LONSDALE
DPDP
DP
DP
SLex SLex
SLex
BOUNDARYFENCE
N
SIDE GATEBO
UNDA
RY
BOUNDARY
FENC
E
CUBBY
FENCET.06
T.08T.09T.10T.11T.12T.13T.14
T.15T.16
T.17T.18T.19
T.20T.21T.22
T.25
T.01
T.02
T.03
T.04
T.07
40.64205°00'
40.64205°00'
15.0
911
5°00
'
SRZ
TPZ
SRZ
TPZ
HW HW NHW NHW
HW
HW
NHW
NHW NHW NHW
HW
JT + GLLEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
+ 5.05
+ 5.32
+ 13.15
+ 5.40
+ 5.60
+ 5.80
+ 6.00
+ 6.10
+ 6.20
+ 6.22
+ 13.15
DWG NO:
REV:SCALE1:100 @ A3DATE
-
PROJECT NO.
COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE
2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.
3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.
DRAWINGEXISTING ELEVATIONSPROJECT
CLIENT
TP.04
BOUN
DARY
FENC
E
BOUN
DARY
FENC
E
1 SOUTH-WEST ELEVATION (STREET)1:100
No. 8 CHESHUNT No.6 CHESHUNTNo.10 CHESHUNT
2 SOUTH-EAST ELEVATION (STREET)1:100
BOUN
DARY
FENC
E
2021_038 CHESHUNT STREET, POINT LONSDALE
20.08.2021
FFL 6.130
ES
SC
B
FFL 6.13
DRAFT ONLY. NOT FOR CONSTRUCTION.
DPDP
BASIC DETAIL SHOWN OF TWOSTOREY BRICK ANDWEATHERBOARD STRUCTUREPROPOSED TO BE DEMOLISHED
BASIC DETAIL SHOWN OFDETACHED TWO STOREY BRICKAND WEATHERBOARDSTRUCTURE PROPOSED TO BEDEMOLISHED AT REAR OFPROPERTY
GROUND LINE AT REARBUILDING
GROUND LINE AT HOUSE
GROUND LINE AT FRONTBOUNDARY
NJT + GL
LEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
+ 6.10
+ 6.10
+ 13.15
+ 6.56
+ 6.40
+ 6.33
+ 6.20
+ 6.12
+ 6.00
+ 5.80
+ 5.60
+ 5.40
+ 13.15
DWG NO:
REV:SCALE1:100 @ A3DATE
-
PROJECT NO.
COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE
2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.
3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.
DRAWINGEXISTING ELEVATIONSPROJECT
CLIENT
TP.05
3 NORTH- EAST ELEVATION (GARDEN)1:100
No.10 CHESHUNTNo.6 CHESHUNT
4 NORTH-WEST ELEVATION1:100
No. 8 CHESHUNT
2021_038 CHESHUNT STREET, POINT LONSDALE
20.08.2021
FFL 6.130
FFL 6.130
DRAFT ONLY. NOT FOR CONSTRUCTION.
B
GM
EM
TB
SPSPSPSP
GPWT
SPSC
F
BOUN
DARY
FENC
E
BOUN
DARY
FENC
E
DP
DP
BASIC DETAIL SHOWN OF TWOSTOREY BRICK ANDWEATHERBOARD STRUCTUREPROPOSED TO BE DEMOLISHED
BOUN
DARY
FENC
E
OUTLINE OF TWO STOREY BRICKAND WEATHERBOARDSTRUCTURE PROPOSED TO BEDEMOLISHED SHOWN DASHEDFORWARD OF HOME
NJT + GL
LEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
+ 6.09
+ 6.12
+ 6.20
+ 6.33
+ 6.40
+ 6.22
+ 5.80
+ 6.00
+ 5.60
+ 5.40
+ 5.20
+ 5.40
+ 5.60
+ 5.80
+ 6.00
+ 6.20
+ 6.56
1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE
2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.
3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL. TP.06
DWG NO:
REV:SCALE1:100 @ A3DATE
-
PROJECT NO.
DRAWING
PROJECT
CLIENTCOMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
DRAFT ONLY. NOT FOR CONSTRUCTION.DEMOLITION PLAN
2021_038 CHESHUNT STREET, POINT LONSDALE
20.08.2021
LIVINGTIMex
BED 1TIMex
BED 2TIMex
CH 3035 CH 3035
CH 4380
CH 3050
HPexHPex
SLex SLex
BED 3CPTex
CH 2580
BED 4CPTex
CH 2580
WCLAMex
BATHLAMex
SHRLAMex
ENSLAMex
CH 2380
KITCHENLAMex
CH 2580
CH 2
810
CH 2
550
CH 2580
CH 2580
MH
1
2
3
4
EM
SIDE GATE
GM
HPex
HPex
HPex
HPex
HPex
DININGTIMex
HWS
BRKex
900mm
1500mmSIDE GATE
DR
DR
BOUNDARY
BOUN
DARY
FIRE
PLAC
E AN
D CH
IMNE
Y
BOUNDARY
SLex
FFL 6.13
FENC
E
BASIC DETAIL SHOWN OF TWO STOREYBRICK AND WEATHERBOARD
STRUCTURE PROPOSED TO BEDEMOLISHED
CUBBY
FENCE
FENCE
T.06
T.08T.09T.10T.11T.12T.13T.14
T.15T.16
T.17T.18T.19
T.20T.21T.22
T.25
T.01
T.02
T.03
T.04
T.07
T.05
40.64205°00'
40.64205°00'
15.0
911
5°00
'
SRZ
TPZ
SRZ
TPZ
N
EXISTING ELECTRICAL POWER LINE CONNECTIONFROM MAIN HOUSE TO DETACHED DWELLING TOBE DISCONNECTED BEFORE DEMOLITION
EXTENT OF DEMOLITION ANDREMOVAL OF TREES/VEGETATIONSHOWN IN RED.
JT + GL
TREE LIMB AND TRIMMINGAS REQUIRED FORPROPOSED POOL
MINOR TRIMMING OF LOW TREE LIMBS TO INCREASESITE ACCESS OF TREES ALONG EASTERN BOUNDARYAS REQUIRED.
LEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
+ 6.09
+ 6.12
+ 6.20
+ 6.33
+ 6.40
+ 6.22
+ 5.80
+ 6.00
+ 5.60
+ 5.40
+ 5.05
+ 5.20
+ 4.86
+ 5.40
+ 5.60+ 5.80
+ 6.00
+ 6.20
+ 4.89
+ 6.56
+ 5.32
DWG NO:
REV:SCALE1:200 @ A3DATE
-
PROJECT NO.2021_03
COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
DRAFT ONLY. NOT FOR CONSTRUCTION.1. BUILDER TO CHECK ALL DIMENSIONS BEFORE
COMMENCING WORKS ON SITE2. BUILDER TO REFER ANY DESCREPANCIES TO
THE ARCHITECT FOR CLARIFICATION.3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.
NDRAWINGPROPOSED SITE PLANPROJECT8 CHESHUNT STREET, POINT LONSDALE
CLIENT
20.08.2021
TP.07
8 CHESHUNTSTREET
BOUNDARY
BOUN
DARY BO
UNDA
RY
BOUNDARY
EM GMWM
EP
GRAVEL CROSSOVER
GRAVEL DRIVEWAY
40.64205°00'
FENCE
40.64205°00'
No.1 ALBERT STREET- SINGLE STOREY BRICKBUILDING METAL ROOF- CHURCH HALL
No.6 CHESHUNT STREETDOUBLE STOREY TIMBERCLAD DWELLINGMETAL ROOF
No.10 CHESHUNT STREETDOUBLE STOREY LIGHTWEIGHTCLAD DWELLINGMETAL ROOF
CP
15.0
929
5°00
'
2.2 HIGH PALING FENCE
1.6
HIGH
PAL
ING
FENC
E15
.09
115°
00'
HEDGE
EOH
2.2 HIGH PALING FENCE WITH 0.5 SCREEN
T.03
T.05
T.06T.07T.08T.09T.10T.11
T.12T.13T.14T.15T.16
T.17T.18T.19
T.20T.21T.22
T.23
T.24
T.25
SRZTPZ
SRZ
TPZPOOL
PROPOSED AREA ANALYSIS
SITE AREA= 613m²
SITE COVERAGE PROPOSED= 201m²(roofed area)
PERCENTAGE= 33%*should not exceed 40% DD04
GARDEN AREA= 359m²PERCENTAGE= 58%*Minimum 30% required- GRZ1
PERMEABLE AREA= 386m²PERCENTAGE= 62%*Minimum 30% required- DD04
HW HW NHW NHW
HW HW
HW
NHW
NHW NHW NHW
POOL
JT + GL
NATURE STRIP TREEPROPOSED TO BETRIMMED AND LIMBSLOPPED TO ALLOWINCREASED SITE ACCESSAND TO CLEAR EXISTINGDRIVEWAY
LEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
+ 6.09
+ 6.12
+ 6.20
+ 6.22
+ 5.80
+ 6.00
+ 5.60
+ 5.40
+ 5.20
+ 5.40
+ 5.60
+ 5.80
+ 6.00
+ 6.20
+ 6.56
1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE
2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.
3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL. TP.08
DWG NO:
REV:SCALE1:100 @ A3DATE
-
PROJECT NO.
DRAWING
PROJECT
CLIENTCOMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
DRAFT ONLY. NOT FOR CONSTRUCTION.PROPOSED GROUND FLOOR PLAN
2021_038 CHESHUNT STREET, POINT LONSDALE
20.08.2021
LIVINGTIMex
BED 1TIMex
CH 3035
CH 4380
CH 3050
SLex SLex
WC
BED 2 ENSKITCHEN
CH 2
550
CH 2580
1
2
3
4
EMGM
HPex
HPex
HPex
HPex
DININGTIMex
FIRE
PLAC
E
FFLx 6.13
T.05
12345
6
78 9
10
11
FRIDGE
PANTRY
UNDERSTAIRSTORAGE
LINE
N
WM
COAT
HOO
KS E
TC
STAI
R
ROBE
DESK
SHELF
L'DRYHALL
BUILT IN CHAIR
FURN
ITUR
E
FURNITUREFURNITURE
1 GROUND FLOOR PLAN1:100
WIR
ROBE
ROBE
SL
SHOWER
ENSUITE
BUIL
T IN
CHA
IR
SL
9'6EXTERNALSTORAGE(LAWN MOWER,GARDENINGTOOLS, ETC)
GASFIRE
STUDIO
SL
POOL
DR
2 3 4 5 67
8
9
10
STAIR1
SIDE GATE
900mm
1500mmSIDE GATE
BOUNDARY
BOUN
DARY
FENC
E
FENCE
T.06
T.08T.09T.10T.11T.12T.13T.14
T.15T.16
T.17T.18T.19
T.20T.21T.22
T.25
T.03
T.07
40.64205°00'
40.64205°00'
15.0
911
5°00
'
SRZ
TPZ
SRZ
TPZ
NEXISTING WALLS TO BE RETAINEDSHOWN IN SOLID HATCH
EXISTING TO RETAINED SHOWN INGREY HATCH
FFL 6.50
8760
1400
EXIS
TING
- NOM
INAL
HW HW NHW NHW
HW
HW
NHW
NHW NHW NHW
HW
4100
9590
13700
22250
77003940
EXTE
RNAL
STO
RAGE
150
6180
150
JT + GL
DECK
FFLx 6.13
LEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
+ 6.09
+ 6.12
+ 6.20
+ 6.22
+ 5.80
+ 6.00
+ 5.60
+ 5.40
+ 5.20
+ 5.40
+ 5.60
+ 5.80
+ 6.00
+ 6.20
+ 6.56
1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE
2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.
3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL. TP.09
DWG NO:
REV:SCALE1:100 @ A3DATE
-
PROJECT NO.
DRAWING
PROJECT
CLIENTCOMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
DRAFT ONLY. NOT FOR CONSTRUCTION.PROPOSED FIRST FLOOR PLAN
2021_038 CHESHUNT STREET, POINT LONSDALE
20.08.2021
EM GM
BOUNDARYFENCE
T.05
40.64205°00'
STORAGE/SHELVING/DESK SPACE
BED 4
2345
6
78 9
10
11121314151617
BED 3 STAI
R
3 FIRST FLOOR PLAN1:100
SL
SL
SLSTUDIO
SHOWER
BATH
HALL
2 3 4 5 67
8
9
10
STAIR
11121314151617
WC
1SL
BALUSTRADE
VOID
DPDP
SLex SLex
POOL
BOUNDARY
BOUN
DARY
FENC
E
FENCE
T.06
T.08T.09T.10T.11T.12T.13T.14
T.15T.16
T.17T.18T.19
T.20T.21T.22
T.25
T.03
T.07
40.64205°00'
40.64205°00'
15.0
911
5°00
'
SRZ
TPZ
SRZ
TPZ
N
SHOWER/BATH
BATHWC
LINE
N
DECK
VERANDAH
SHELF
HW HW NHW NHW
HW
HW
NHW
NHW NHW NHW
HW
1100
1100
150
950
4650
7100
1100
4400
1200
8385
13700 4540 150
9340
3365
9m OVE
RLOOKIN
G ARC 45° 9m OVERLOOKING ARC 45°
9m OVERLOOKING ARC 45°
9m OVE
RLOOKIN
G ARC 45°
9m OVE
RLOOKIN
G ARC 45°
NON HABITABLE WINDOWSILL HEIGHT 1700mm
SILL
HEI
GHT
1700
mm
SILL
HEI
GHT
1700
mm
SILL HEIGHT 1700mmSILL HEIGHT 1700mmSILL HEIGHT 1700mmSILL HEIGHT 1700mmSILL HEIGHT 1700mm
NON HABITABLE WINDOWNON HABITABLE WINDOW
JT + GL
FFL 9.55
FFL 9.15
EXISTING WALLS TO BE RETAINEDSHOWN IN SOLID HATCH
EXISTING TO RETAINED SHOWN INGREY HATCH
LEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
+ 6.09
+ 6.12
+ 6.20
+ 6.22
+ 5.80
+ 6.00
+ 5.60
+ 5.40
+ 5.40
+ 5.60
+ 5.80
+ 6.00
+ 6.20
+ 6.56
TP.10DWG NO:
REV:SCALE1:100 @ A3DATE
-
PROJECT NO.
COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
20.08.2021
1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE
2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.
3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.
DRAWINGPROPOSED ROOF PLANPROJECT
CLIENT
DRAFT ONLY. NOT FOR CONSTRUCTION.
2021_038 CHESHUNT STREET, POINT LONSDALE
BOUNDARY
SLex SLex
BOUNDARY
BOUN
DARY
BOUNDARY
FENC
E
FENCE
FENCE
N
DECK
POOL
BOUNDARY
BOUN
DARY
FENC
E
FENCE
T.06
T.08T.09T.10T.11T.12T.13T.14
T.15T.16
T.17T.18T.19
T.20T.21
T.25
T.03
T.07
40.64205°00'
40.64205°00'
15.0
911
5°00
'
SRZ
TPZ
SRZ
TPZ
HW HW NHW NHW
HW
HW
NHW
NHW NHW NHW
HW
SL
SL
SLSL
SL
JT + GL
PROPOSED LOCATION FOR SOLAR PANELS
EXISTING WALLS TO BE RETAINEDSHOWN IN SOLID HATCH
EXISTING TO RETAINED SHOWN INGREY HATCH
LEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
DWG NO:
REV:SCALE1:100 @ A3DATE
-
PROJECT NO.
COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE
2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.
3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.
DRAWINGPROPOSED ELEVATIONSPROJECT
CLIENT
TP.11
BOUN
DARY
FENC
E
BOUN
DARY
FENC
E
1 PROPOSED SOUTH-WEST ELEVATION (STREET)1:100
No. 8 CHESHUNT No.6 CHESHUNTNo.10 CHESHUNT
3 PRPOSED SOUTH-EAST ELEVATION1:100
BOUN
DARY
FENC
E
2021_038 CHESHUNT STREET, POINT LONSDALE
20.08.2021
FFLx 6.130
FFLx 6.13
DRAFT ONLY. NOT FOR CONSTRUCTION.
NEW SKYLIGHT INTEGRATED INTO EXISTING ROOF
NEW PORCH POSTS AND BALUSTRADE PROPOSED
DESIGN DEVELOPMENT OVERLAY MAXIMUMBUILDING HEIGHT RESTRICTION OF 8.5 METRESSHOWN ABOVE NATURAL GROUND LINE
OUTLINE OF EXISTING REAR STRUCTURE SHOWNFOR COMPARISON OF EXISTING AND PROPOSED.
EXISTING GROUND LINE AT FRONT BOUNDARY
EXISTING GROUND LINE AT EXISTING HOUSE
EXISTING GROUND LINE AT REAR DWELLING
NEW TIMBER CLADDING PROPOSED TO FRONTDWELLING AND PORCH AREA.
NEW TIMBER CLADDING PROPOSED TO FRONTPORCH AREA WITH NEW POSTS AND BALUSTERS
NEW FIRST STORY EXTENSION
ENCROACHMENT AREA OF PROPOSED DWELLINGREQUIRING CONSENT TO BUILD WITHIN SETBACK.
OUTLINE OF EXISTING REAR STRUCTURE SHOWNFOR COMPARISON OF EXISTING AND PROPOSED.
N
2 PROPOSED SOUTH-WEST ELEVATION (STUDIO)1:100
BOUN
DARY
FENC
E
ENCROACHMENT AREA OF PROPOSED DWELLINGREQUIRING CONSENT TO BUILD WITHIN SETBACK.
PROPOSED NEW DETACHED STUDIO OUTLINEDBEYOND. NOTE- HIGHER GROUND BEYOND
JT + GL
FCS1
FCS2
FCS2FCS2WBD
WBDWBD
TIM1
TIM
1
FCS3
FCS3
TIM1
TIM
1
1700
FFL 6.50
FFL 9.55
FFL 6.50
FFL 9.55
2200
FFL 9.150
WBD
7700
7250
TIM1
FCS2
EXISTING WALLS TO BE RETAINEDSHOWN IN SOLID HATCH
EXISTING TO RETAINED SHOWN INGREY HATCH
LEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
TIM1
TIM1
4000
2400
FFL 9.150
DWG NO:
REV:SCALE1:100 @ A3DATE
-
PROJECT NO.
COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184
1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE
2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.
3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.
DRAWINGPROPOSED ELEVATIONSPROJECT
CLIENT
TP.12
4 PROPOSED MAIN HOUSE NORTH- EAST ELEVATION (GARDEN)1:100
6 PROPOSED NORTH-WEST ELEVATION1:100
2021_038 CHESHUNT STREET, POINT LONSDALE
20.08.2021
FFLx 6.130
FFL 6.500
DRAFT ONLY. NOT FOR CONSTRUCTION.
B
GM
EM
TB
BOUN
DARY
FENC
E
BOUN
DARY
FENC
E
BOUN
DARY
FENC
E
FFL 9.150
OUTLINE OF EXISTING REAR STRUCTURE SHOWNFOR COMPARISON OF EXISTING AND PROPOSED.
EXISTING HOME SHOWN HATCHED GREY ASEXISTING CONDITIONS
NEW FIRST FLOOR DECK AND BALUSTRADE. COUNCIL CONSENT REQUIRED FOR AREAS OFENCROACHMENT WITHIN STANDARD BUILDINGREGULATION AND DESIGN DEVELOPMENTOVERLAY SIDE SETBACK LINE.
N
FFLx 6.130
5 PROPOSED STUDIO NORTH- EAST ELEVATION (GARDEN)1:100
EXISTING SINGLE STOREY DWELLING SHOWNOUTLINED BEYOND
OUTLINE OF EXISTING REAR STRUCTURE SHOWNFOR COMPARISON OF EXISTING AND PROPOSED.
FFL 6.500
JT + GL
1700
NEW BALUSTRADE OUTLINE BEYOND
DESIGN DEVELOPMENT OVERLAY MAXIMUMBUILDING HEIGHT RESTRICTION OF 8.5 METRESSHOWN ABOVE NATURAL GROUND LINE.
OUTLINE OF EXISTING REAR STRUCTURE SHOWNFOR COMPARISON OF EXISTING AND PROPOSED.TIM1
WBD
TIM1
FCS1
FCS2BRK1
FCS2
FCS2
WBD
FFL 9.150
BRK1
FCS3
FFL 9.55
NON HABITABLE WINDOW
2200
EXISTING WALLS TO BE RETAINEDSHOWN IN SOLID HATCH
EXISTING TO RETAINED SHOWN INGREY HATCH
LEGENDACU AIR-CONDITIONING EXTERNAL
UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE
EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL
EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW
HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1
TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP
3900
3700
7600
3900
2400
1300
7600
1300
2400
4000
7700
5800
1450
1450
6200
FFL 9.550