client: jt + gl project: proposed alterations + …

13
DWG NO. TP.00 TP.01 TP.02 TP.03 TP.04 TP.05 TP.06 TP.07 TP.08 TP.09 TP.10 TP.11 TP.12 DRAWING TITLE COVER PAGE, DRAWING REGISTER + SITE CONTEXT PLAN EXISTING SITE PLAN EXISTING FLOOR PLAN EXISTING ROOF PLAN EXISTING ELEVATIONS EXISTING ELEVATIONS DEMOLITION PLAN PROPOSED SITE PLAN PROPOSED GROUND FLOOR PLAN PROPOSED FIRST FLOOR PLAN PROPOSED ROOF PLAN PROPOSED ELEVATIONS PROPOSED ELEVATIONS REVISION - - - - - - - - - - - - - DATE 20.08.2021 20.08.2021 20.08.2021 20.08.2021 20.08.2021 20.08.2021 20.08.2021 20.08.2021 20.08.2021 20.08.2021 20.08.2021 20.08.2021 20.08.2021 TP.00 DWG NO: REV: SCALE N/A DATE - PROJECT NO. COMPANY: FRECKLE ARCHITECTURE PTY LTD CONTACT: SHINAE VREDENBREGT PHONE: 0422 687 188 EMAIL: [email protected] ADDRESS: PO BOX 762, OCEAN GROVE, VIC, 3226 ABN: 95 638 677 184 CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + ADDITIONS ADDRESS: 8 CHESHUNT STREET, POINT LONSDALE, 3225 DRAWING REGISTER 1. BUILDER TO CHECK ALL DIMENSIONS BEFORE COMMENCING WORKS ON SITE 2. BUILDER TO REFER ANY DESCREPANCIES TO THE ARCHITECT FOR CLARIFICATION. 3. DO NOT SCALE FROM DRAWINGS. 4. ALL DIMENSIONS ARE STRUCTURAL. DRAWING COVER PAGE, DRAWING TRANSMITTAL + SITE CONTEXT PLAN PROJECT CLIENT DRAFT ONLY. NOT FOR CONSTRUCTION. 2021_03 8 CHESHUNT STREET, POINT LONSDALE JT + GL 20.08.2021 N D 1 SITE CONTEXT PLAN A C CHESHUNT STREET CHESHUNT STREET POINT LONSDALE ROAD POINT LONSDALE SHOPS KIRK ROAD A No. 8 CHESHUNT No.8 No.6 No.10 B B No. 8 CHESHUNT C No. 10 CHESHUNT D No. 6 CHESHUNT LEGEND ACU AIR-CONDITIONING EXTERNAL UNIT CP COMMUNICATIONS PIT DR DRAIN HWex HOT WATER UNIT EXISTING EM ELECTRICAL METER EP ELECTRICAL POLE EPt ELECTRICAL PIT EOH ELECTRICAL OVERHEAD LINE FFLx FINISHED FLOOR LEVEL EXISTING FFL FINISHED FLOOR LEVEL GM GAS METER HP HYDRONIC HEATING PANEL HW HABITABLE WINDOW HWS HOT WATER SERVICE MH MAN HOLE NHW NON-HABITABLE WINDOW SLex SKYLIGHT EXISTING SL SKYLIGHT PROPOSED SP SEWER PIT SRZ STRUCTURAL ROOT ZONE T.01 TREE No.1 TP TELSTRA PIT TPZ TREE PROTECTION ZONE WM WATER METER WT WATER TAP MATERIAL LEGEND BRK1 BRICKWORK- DARK TIM1 TIMBER CLADDING WBD WEATHERBOARD- EXISTING FCS1 FIBRE CEMENT SHEET AND BATTENS- EXISTING FCS2 JAMES HARDIE SCYON STRIA CLADDING- WHITE PAINT FINISH- HORIZONTAL FCS3 JAMES HARDIE SCYON STRIA CLADDING- CHARCOAL PAINT FINISH- VERTICAL

Upload: others

Post on 12-Jan-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

DWG NO.

TP.00

TP.01

TP.02

TP.03

TP.04

TP.05

TP.06

TP.07

TP.08

TP.09

TP.10

TP.11

TP.12

DRAWING TITLE

COVER PAGE, DRAWING REGISTER + SITE CONTEXT PLAN

EXISTING SITE PLAN

EXISTING FLOOR PLAN

EXISTING ROOF PLAN

EXISTING ELEVATIONS

EXISTING ELEVATIONS

DEMOLITION PLAN

PROPOSED SITE PLAN

PROPOSED GROUND FLOOR PLAN

PROPOSED FIRST FLOOR PLAN

PROPOSED ROOF PLAN

PROPOSED ELEVATIONS

PROPOSED ELEVATIONS

REVISION

-

-

-

-

-

-

-

-

-

-

-

-

-

DATE

20.08.2021

20.08.2021

20.08.2021

20.08.2021

20.08.2021

20.08.2021

20.08.2021

20.08.2021

20.08.2021

20.08.2021

20.08.2021

20.08.2021

20.08.2021

TP.00DWG NO:

REV:SCALEN/ADATE

-

PROJECT NO.

COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

CLIENT: JT + GL

PROJECT: PROPOSED ALTERATIONS + ADDITIONS

ADDRESS: 8 CHESHUNT STREET, POINT LONSDALE, 3225

DRAWING REGISTER

1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE

2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.

3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.

DRAWINGCOVER PAGE, DRAWING TRANSMITTAL + SITE CONTEXT PLANPROJECT

CLIENT

DRAFT ONLY. NOT FOR CONSTRUCTION.

2021_038 CHESHUNT STREET, POINT LONSDALE

JT + GL

20.08.2021

N

D

1 SITE CONTEXT PLAN

A

C

CHESHUNT STREET

CHESHUNT STREET

POIN

T LO

NSDA

LE R

OAD

POIN

T LO

NSDA

LE S

HOPS

KIRK ROAD

A No. 8 CHESHUNT

No.8

No.6

No.10

B

B No. 8 CHESHUNT

C No. 10 CHESHUNT

D No. 6 CHESHUNT

LEGENDACU AIR-CONDITIONINGEXTERNAL UNITCP COMMUNICATIONSPITDR DRAINHWex HOT WATERUNIT EXISTING

EM ELECTRICAL METEREP ELECTRICAL POLEEPt ELECTRICAL PITEOH ELECTRICALOVERHEAD LINEFFLx FINISHED FLOORLEVEL EXISTINGFFL FINISHED FLOOR

LEVELGM GAS METERHP HYDRONIC HEATINGPANELHW HABITABLE WINDOWHWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE

WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOTZONET.01 TREE No.1TP TELSTRA PIT

TPZ TREE PROTECTIONZONEWM WATER METERWT WATER TAP

MATERIAL LEGEND

BRK1 BRICKWORK- DARK

TIM1 TIMBER CLADDING

WBD WEATHERBOARD- EXISTING

FCS1 FIBRE CEMENT SHEET AND BATTENS- EXISTING

FCS2 JAMES HARDIE SCYON STRIA CLADDING- WHITE PAINT FINISH- HORIZONTAL

FCS3 JAMES HARDIE SCYON STRIA CLADDING- CHARCOAL PAINT FINISH- VERTICAL

Page 2: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

+ 6.09

+ 6.12

+ 6.20

+ 6.33

+ 6.40

+ 6.22

+ 5.80

+ 6.00

+ 5.60

+ 5.40

+ 5.05

+ 5.20

+ 4.86

+ 5.40

+ 5.60

+ 5.80

+ 6.00

+ 6.20

+ 4.89

+ 6.56

+ 5.32

EXISTING AREA ANALYSIS

SITE AREA= 613m²

SITE COVERAGE= 228m²(roofed area)

PERCENTAGE= 37%*should not exceed 40% DD04

GARDEN AREA= 315m²PERCENTAGE= 51%*Minimum 30% required- GRZ1

PERMEABLE AREA= 363m²PERCENTAGE= 59%*Minimum 30% required- DD04

DWG NO:

REV:SCALE1:200 @ A3DATE

-

PROJECT NO.2021_03

COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

DRAFT ONLY. NOT FOR CONSTRUCTION.1. BUILDER TO CHECK ALL DIMENSIONS BEFORE

COMMENCING WORKS ON SITE2. BUILDER TO REFER ANY DESCREPANCIES TO

THE ARCHITECT FOR CLARIFICATION.3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.

DRAWINGEXISTING SITE PLANPROJECT8 CHESHUNT STREET, POINT LONSDALE

CLIENT

20.08.2021

TP.01

8 CHESHUNTSTREET

BOUNDARY

BOUN

DARY BO

UNDA

RY

BOUNDARY

EM GM

LEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

WM

EP

GRAVEL CROSSOVER

GRAVEL DRIVEWAY

40.64205°00'

FENCE

40.64205°00'

No.1 ALBERT STREET- SINGLE STOREY BRICKBUILDING METAL ROOF- CHURCH HALL

No.6 CHESHUNT STREETDOUBLE STOREY TIMBERCLAD DWELLINGMETAL ROOF

No.10 CHESHUNT STREETDOUBLE STOREY LIGHTWEIGHTCLAD DWELLINGMETAL ROOF

CP

15.0

929

5°00

'

2.2 HIGH PALING FENCE

1.6

HIGH

PAL

ING

FENC

E15

.09

115°

00'

HEDGE

EOH

EOH

2.2 HIGH PALING FENCE WITH 0.5 SCREEN

T.01

T.02

T.03

T.04

T.05

T.06T.07T.08T.09T.10T.11

T.12T.13T.14T.15T.16

T.17T.18T.19

T.20T.21T.22

T.23

T.24

T.25

SRZTPZ

SRZ

TPZ

N

HW HW NHW NHW

HW HW

HW

NHW

NHW NHW NHW

POOL

CHES

HUNT

STR

EET

JT + GL

Page 3: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

+ 6.09

+ 6.12

+ 6.20

+ 6.33

+ 6.40

+ 6.22

+ 5.80

+ 6.00

+ 5.60

+ 5.40

+ 5.20

+ 5.40

+ 5.60

+ 5.80

+ 6.00

+ 6.20

+ 6.56

1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE

2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.

3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL. TP.02

DWG NO:

REV:SCALE1:100 @ A3DATE

-

PROJECT NO.

DRAWING

PROJECT

CLIENTCOMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

DRAFT ONLY. NOT FOR CONSTRUCTION.EXISTING GROUND FLOOR PLAN

2021_038 CHESHUNT STREET, POINT LONSDALE

20.08.2021

LIVINGTIMex

BED 1TIMex

BED 2TIMex

CH 3035 CH 3035

CH 4380

CH 3050

HPexHPex

SLex SLex

BED 3CPTex

CH 2580

BED 4CPTex

CH 2580

WCLAMex

BATHLAMex

SHRLAMex

ENSLAMex

CH 2380

KITCHENLAMex

CH 2580

CH 2

810

CH 2

550

CH 2580

CH 2580

MH

1

2

3

4

EM

SIDE GATE

GM

HPex

HPex

HPex

HPex

HPex

DININGTIMex

HWS

BRKex

900mm

1500mmSIDE GATE

DR

DR

BOUNDARY

BOUN

DARY

FIRE

PLAC

E AN

D CH

IMNE

Y

BOUNDARY

SLex

FFLx 6.13

FENC

E

BASIC DETAIL SHOWN OF TWO STOREYBRICK AND WEATHERBOARD STRUCTURE

PROPOSED TO BE DEMOLISHED.

DETACHED DWELLING CONSISTS OF ABEDROOM, BATHROOM, KITCHEN, LIVING,

LAUNDRY AND STORAGE

CUBBY

FENCE

FENCE

T.06

T.08T.09T.10T.11T.12T.13T.14

T.15T.16

T.17T.18T.19

T.20T.21T.22

T.25

T.01

T.02

T.03

T.04

T.07

T.05

40.64205°00'

40.64205°00'

15.0

911

5°00

'

SRZ

TPZ

SRZ

TPZ

N

13700

1400

EXIS

TING

- NOM

INAL

HW HW NHW NHW

HW

HW

NHW

NHW NHW NHW

HW

EXISTING- NOMINAL

3815

.00

EXIS

TING

- NOM

INAL

8890.01

1182

9.53

JT + GLLEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

Page 4: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

+ 6.09

+ 6.12

+ 6.20

+ 6.33

+ 6.40

+ 6.22

+ 5.80

+ 6.00

+ 5.60

+ 5.40

+ 5.40

+ 5.60

+ 5.80

+ 6.00

+ 6.20

+ 6.56

TP.03DWG NO:

REV:SCALE1:100 @ A3DATE

-

PROJECT NO.

COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

20.08.2021

1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE

2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.

3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.

DRAWINGEXISTING ROOF PLANPROJECT

CLIENT

DRAFT ONLY. NOT FOR CONSTRUCTION.

2021_038 CHESHUNT STREET, POINT LONSDALE

DPDP

DP

DP

SLex SLex

SLex

BOUNDARYFENCE

N

SIDE GATEBO

UNDA

RY

BOUNDARY

FENC

E

CUBBY

FENCET.06

T.08T.09T.10T.11T.12T.13T.14

T.15T.16

T.17T.18T.19

T.20T.21T.22

T.25

T.01

T.02

T.03

T.04

T.07

40.64205°00'

40.64205°00'

15.0

911

5°00

'

SRZ

TPZ

SRZ

TPZ

HW HW NHW NHW

HW

HW

NHW

NHW NHW NHW

HW

JT + GLLEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

Page 5: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

+ 5.05

+ 5.32

+ 13.15

+ 5.40

+ 5.60

+ 5.80

+ 6.00

+ 6.10

+ 6.20

+ 6.22

+ 13.15

DWG NO:

REV:SCALE1:100 @ A3DATE

-

PROJECT NO.

COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE

2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.

3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.

DRAWINGEXISTING ELEVATIONSPROJECT

CLIENT

TP.04

BOUN

DARY

FENC

E

BOUN

DARY

FENC

E

1 SOUTH-WEST ELEVATION (STREET)1:100

No. 8 CHESHUNT No.6 CHESHUNTNo.10 CHESHUNT

2 SOUTH-EAST ELEVATION (STREET)1:100

BOUN

DARY

FENC

E

2021_038 CHESHUNT STREET, POINT LONSDALE

20.08.2021

FFL 6.130

ES

SC

B

FFL 6.13

DRAFT ONLY. NOT FOR CONSTRUCTION.

DPDP

BASIC DETAIL SHOWN OF TWOSTOREY BRICK ANDWEATHERBOARD STRUCTUREPROPOSED TO BE DEMOLISHED

BASIC DETAIL SHOWN OFDETACHED TWO STOREY BRICKAND WEATHERBOARDSTRUCTURE PROPOSED TO BEDEMOLISHED AT REAR OFPROPERTY

GROUND LINE AT REARBUILDING

GROUND LINE AT HOUSE

GROUND LINE AT FRONTBOUNDARY

NJT + GL

LEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

Page 6: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

+ 6.10

+ 6.10

+ 13.15

+ 6.56

+ 6.40

+ 6.33

+ 6.20

+ 6.12

+ 6.00

+ 5.80

+ 5.60

+ 5.40

+ 13.15

DWG NO:

REV:SCALE1:100 @ A3DATE

-

PROJECT NO.

COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE

2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.

3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.

DRAWINGEXISTING ELEVATIONSPROJECT

CLIENT

TP.05

3 NORTH- EAST ELEVATION (GARDEN)1:100

No.10 CHESHUNTNo.6 CHESHUNT

4 NORTH-WEST ELEVATION1:100

No. 8 CHESHUNT

2021_038 CHESHUNT STREET, POINT LONSDALE

20.08.2021

FFL 6.130

FFL 6.130

DRAFT ONLY. NOT FOR CONSTRUCTION.

B

GM

EM

TB

SPSPSPSP

GPWT

SPSC

F

BOUN

DARY

FENC

E

BOUN

DARY

FENC

E

DP

DP

BASIC DETAIL SHOWN OF TWOSTOREY BRICK ANDWEATHERBOARD STRUCTUREPROPOSED TO BE DEMOLISHED

BOUN

DARY

FENC

E

OUTLINE OF TWO STOREY BRICKAND WEATHERBOARDSTRUCTURE PROPOSED TO BEDEMOLISHED SHOWN DASHEDFORWARD OF HOME

NJT + GL

LEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

Page 7: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

+ 6.09

+ 6.12

+ 6.20

+ 6.33

+ 6.40

+ 6.22

+ 5.80

+ 6.00

+ 5.60

+ 5.40

+ 5.20

+ 5.40

+ 5.60

+ 5.80

+ 6.00

+ 6.20

+ 6.56

1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE

2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.

3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL. TP.06

DWG NO:

REV:SCALE1:100 @ A3DATE

-

PROJECT NO.

DRAWING

PROJECT

CLIENTCOMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

DRAFT ONLY. NOT FOR CONSTRUCTION.DEMOLITION PLAN

2021_038 CHESHUNT STREET, POINT LONSDALE

20.08.2021

LIVINGTIMex

BED 1TIMex

BED 2TIMex

CH 3035 CH 3035

CH 4380

CH 3050

HPexHPex

SLex SLex

BED 3CPTex

CH 2580

BED 4CPTex

CH 2580

WCLAMex

BATHLAMex

SHRLAMex

ENSLAMex

CH 2380

KITCHENLAMex

CH 2580

CH 2

810

CH 2

550

CH 2580

CH 2580

MH

1

2

3

4

EM

SIDE GATE

GM

HPex

HPex

HPex

HPex

HPex

DININGTIMex

HWS

BRKex

900mm

1500mmSIDE GATE

DR

DR

BOUNDARY

BOUN

DARY

FIRE

PLAC

E AN

D CH

IMNE

Y

BOUNDARY

SLex

FFL 6.13

FENC

E

BASIC DETAIL SHOWN OF TWO STOREYBRICK AND WEATHERBOARD

STRUCTURE PROPOSED TO BEDEMOLISHED

CUBBY

FENCE

FENCE

T.06

T.08T.09T.10T.11T.12T.13T.14

T.15T.16

T.17T.18T.19

T.20T.21T.22

T.25

T.01

T.02

T.03

T.04

T.07

T.05

40.64205°00'

40.64205°00'

15.0

911

5°00

'

SRZ

TPZ

SRZ

TPZ

N

EXISTING ELECTRICAL POWER LINE CONNECTIONFROM MAIN HOUSE TO DETACHED DWELLING TOBE DISCONNECTED BEFORE DEMOLITION

EXTENT OF DEMOLITION ANDREMOVAL OF TREES/VEGETATIONSHOWN IN RED.

JT + GL

TREE LIMB AND TRIMMINGAS REQUIRED FORPROPOSED POOL

MINOR TRIMMING OF LOW TREE LIMBS TO INCREASESITE ACCESS OF TREES ALONG EASTERN BOUNDARYAS REQUIRED.

LEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

Page 8: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

+ 6.09

+ 6.12

+ 6.20

+ 6.33

+ 6.40

+ 6.22

+ 5.80

+ 6.00

+ 5.60

+ 5.40

+ 5.05

+ 5.20

+ 4.86

+ 5.40

+ 5.60+ 5.80

+ 6.00

+ 6.20

+ 4.89

+ 6.56

+ 5.32

DWG NO:

REV:SCALE1:200 @ A3DATE

-

PROJECT NO.2021_03

COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

DRAFT ONLY. NOT FOR CONSTRUCTION.1. BUILDER TO CHECK ALL DIMENSIONS BEFORE

COMMENCING WORKS ON SITE2. BUILDER TO REFER ANY DESCREPANCIES TO

THE ARCHITECT FOR CLARIFICATION.3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.

NDRAWINGPROPOSED SITE PLANPROJECT8 CHESHUNT STREET, POINT LONSDALE

CLIENT

20.08.2021

TP.07

8 CHESHUNTSTREET

BOUNDARY

BOUN

DARY BO

UNDA

RY

BOUNDARY

EM GMWM

EP

GRAVEL CROSSOVER

GRAVEL DRIVEWAY

40.64205°00'

FENCE

40.64205°00'

No.1 ALBERT STREET- SINGLE STOREY BRICKBUILDING METAL ROOF- CHURCH HALL

No.6 CHESHUNT STREETDOUBLE STOREY TIMBERCLAD DWELLINGMETAL ROOF

No.10 CHESHUNT STREETDOUBLE STOREY LIGHTWEIGHTCLAD DWELLINGMETAL ROOF

CP

15.0

929

5°00

'

2.2 HIGH PALING FENCE

1.6

HIGH

PAL

ING

FENC

E15

.09

115°

00'

HEDGE

EOH

2.2 HIGH PALING FENCE WITH 0.5 SCREEN

T.03

T.05

T.06T.07T.08T.09T.10T.11

T.12T.13T.14T.15T.16

T.17T.18T.19

T.20T.21T.22

T.23

T.24

T.25

SRZTPZ

SRZ

TPZPOOL

PROPOSED AREA ANALYSIS

SITE AREA= 613m²

SITE COVERAGE PROPOSED= 201m²(roofed area)

PERCENTAGE= 33%*should not exceed 40% DD04

GARDEN AREA= 359m²PERCENTAGE= 58%*Minimum 30% required- GRZ1

PERMEABLE AREA= 386m²PERCENTAGE= 62%*Minimum 30% required- DD04

HW HW NHW NHW

HW HW

HW

NHW

NHW NHW NHW

POOL

JT + GL

NATURE STRIP TREEPROPOSED TO BETRIMMED AND LIMBSLOPPED TO ALLOWINCREASED SITE ACCESSAND TO CLEAR EXISTINGDRIVEWAY

LEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

Page 9: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

+ 6.09

+ 6.12

+ 6.20

+ 6.22

+ 5.80

+ 6.00

+ 5.60

+ 5.40

+ 5.20

+ 5.40

+ 5.60

+ 5.80

+ 6.00

+ 6.20

+ 6.56

1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE

2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.

3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL. TP.08

DWG NO:

REV:SCALE1:100 @ A3DATE

-

PROJECT NO.

DRAWING

PROJECT

CLIENTCOMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

DRAFT ONLY. NOT FOR CONSTRUCTION.PROPOSED GROUND FLOOR PLAN

2021_038 CHESHUNT STREET, POINT LONSDALE

20.08.2021

LIVINGTIMex

BED 1TIMex

CH 3035

CH 4380

CH 3050

SLex SLex

WC

BED 2 ENSKITCHEN

CH 2

550

CH 2580

1

2

3

4

EMGM

HPex

HPex

HPex

HPex

DININGTIMex

FIRE

PLAC

E

FFLx 6.13

T.05

12345

6

78 9

10

11

FRIDGE

PANTRY

UNDERSTAIRSTORAGE

LINE

N

WM

COAT

HOO

KS E

TC

STAI

R

ROBE

DESK

SHELF

L'DRYHALL

BUILT IN CHAIR

FURN

ITUR

E

FURNITUREFURNITURE

1 GROUND FLOOR PLAN1:100

WIR

ROBE

ROBE

SL

SHOWER

ENSUITE

BUIL

T IN

CHA

IR

SL

9'6EXTERNALSTORAGE(LAWN MOWER,GARDENINGTOOLS, ETC)

GASFIRE

STUDIO

SL

POOL

DR

2 3 4 5 67

8

9

10

STAIR1

SIDE GATE

900mm

1500mmSIDE GATE

BOUNDARY

BOUN

DARY

FENC

E

FENCE

T.06

T.08T.09T.10T.11T.12T.13T.14

T.15T.16

T.17T.18T.19

T.20T.21T.22

T.25

T.03

T.07

40.64205°00'

40.64205°00'

15.0

911

5°00

'

SRZ

TPZ

SRZ

TPZ

NEXISTING WALLS TO BE RETAINEDSHOWN IN SOLID HATCH

EXISTING TO RETAINED SHOWN INGREY HATCH

FFL 6.50

8760

1400

EXIS

TING

- NOM

INAL

HW HW NHW NHW

HW

HW

NHW

NHW NHW NHW

HW

4100

9590

13700

22250

77003940

EXTE

RNAL

STO

RAGE

150

6180

150

JT + GL

DECK

FFLx 6.13

LEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

Page 10: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

+ 6.09

+ 6.12

+ 6.20

+ 6.22

+ 5.80

+ 6.00

+ 5.60

+ 5.40

+ 5.20

+ 5.40

+ 5.60

+ 5.80

+ 6.00

+ 6.20

+ 6.56

1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE

2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.

3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL. TP.09

DWG NO:

REV:SCALE1:100 @ A3DATE

-

PROJECT NO.

DRAWING

PROJECT

CLIENTCOMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

DRAFT ONLY. NOT FOR CONSTRUCTION.PROPOSED FIRST FLOOR PLAN

2021_038 CHESHUNT STREET, POINT LONSDALE

20.08.2021

EM GM

BOUNDARYFENCE

T.05

40.64205°00'

STORAGE/SHELVING/DESK SPACE

BED 4

2345

6

78 9

10

11121314151617

BED 3 STAI

R

3 FIRST FLOOR PLAN1:100

SL

SL

SLSTUDIO

SHOWER

BATH

HALL

2 3 4 5 67

8

9

10

STAIR

11121314151617

WC

1SL

BALUSTRADE

VOID

DPDP

SLex SLex

POOL

BOUNDARY

BOUN

DARY

FENC

E

FENCE

T.06

T.08T.09T.10T.11T.12T.13T.14

T.15T.16

T.17T.18T.19

T.20T.21T.22

T.25

T.03

T.07

40.64205°00'

40.64205°00'

15.0

911

5°00

'

SRZ

TPZ

SRZ

TPZ

N

SHOWER/BATH

BATHWC

LINE

N

DECK

VERANDAH

SHELF

HW HW NHW NHW

HW

HW

NHW

NHW NHW NHW

HW

1100

1100

150

950

4650

7100

1100

4400

1200

8385

13700 4540 150

9340

3365

9m OVE

RLOOKIN

G ARC 45° 9m OVERLOOKING ARC 45°

9m OVERLOOKING ARC 45°

9m OVE

RLOOKIN

G ARC 45°

9m OVE

RLOOKIN

G ARC 45°

NON HABITABLE WINDOWSILL HEIGHT 1700mm

SILL

HEI

GHT

1700

mm

SILL

HEI

GHT

1700

mm

SILL HEIGHT 1700mmSILL HEIGHT 1700mmSILL HEIGHT 1700mmSILL HEIGHT 1700mmSILL HEIGHT 1700mm

NON HABITABLE WINDOWNON HABITABLE WINDOW

JT + GL

FFL 9.55

FFL 9.15

EXISTING WALLS TO BE RETAINEDSHOWN IN SOLID HATCH

EXISTING TO RETAINED SHOWN INGREY HATCH

LEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

Page 11: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

+ 6.09

+ 6.12

+ 6.20

+ 6.22

+ 5.80

+ 6.00

+ 5.60

+ 5.40

+ 5.40

+ 5.60

+ 5.80

+ 6.00

+ 6.20

+ 6.56

TP.10DWG NO:

REV:SCALE1:100 @ A3DATE

-

PROJECT NO.

COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

20.08.2021

1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE

2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.

3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.

DRAWINGPROPOSED ROOF PLANPROJECT

CLIENT

DRAFT ONLY. NOT FOR CONSTRUCTION.

2021_038 CHESHUNT STREET, POINT LONSDALE

BOUNDARY

SLex SLex

BOUNDARY

BOUN

DARY

BOUNDARY

FENC

E

FENCE

FENCE

N

DECK

POOL

BOUNDARY

BOUN

DARY

FENC

E

FENCE

T.06

T.08T.09T.10T.11T.12T.13T.14

T.15T.16

T.17T.18T.19

T.20T.21

T.25

T.03

T.07

40.64205°00'

40.64205°00'

15.0

911

5°00

'

SRZ

TPZ

SRZ

TPZ

HW HW NHW NHW

HW

HW

NHW

NHW NHW NHW

HW

SL

SL

SLSL

SL

JT + GL

PROPOSED LOCATION FOR SOLAR PANELS

EXISTING WALLS TO BE RETAINEDSHOWN IN SOLID HATCH

EXISTING TO RETAINED SHOWN INGREY HATCH

LEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

Page 12: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

DWG NO:

REV:SCALE1:100 @ A3DATE

-

PROJECT NO.

COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE

2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.

3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.

DRAWINGPROPOSED ELEVATIONSPROJECT

CLIENT

TP.11

BOUN

DARY

FENC

E

BOUN

DARY

FENC

E

1 PROPOSED SOUTH-WEST ELEVATION (STREET)1:100

No. 8 CHESHUNT No.6 CHESHUNTNo.10 CHESHUNT

3 PRPOSED SOUTH-EAST ELEVATION1:100

BOUN

DARY

FENC

E

2021_038 CHESHUNT STREET, POINT LONSDALE

20.08.2021

FFLx 6.130

FFLx 6.13

DRAFT ONLY. NOT FOR CONSTRUCTION.

NEW SKYLIGHT INTEGRATED INTO EXISTING ROOF

NEW PORCH POSTS AND BALUSTRADE PROPOSED

DESIGN DEVELOPMENT OVERLAY MAXIMUMBUILDING HEIGHT RESTRICTION OF 8.5 METRESSHOWN ABOVE NATURAL GROUND LINE

OUTLINE OF EXISTING REAR STRUCTURE SHOWNFOR COMPARISON OF EXISTING AND PROPOSED.

EXISTING GROUND LINE AT FRONT BOUNDARY

EXISTING GROUND LINE AT EXISTING HOUSE

EXISTING GROUND LINE AT REAR DWELLING

NEW TIMBER CLADDING PROPOSED TO FRONTDWELLING AND PORCH AREA.

NEW TIMBER CLADDING PROPOSED TO FRONTPORCH AREA WITH NEW POSTS AND BALUSTERS

NEW FIRST STORY EXTENSION

ENCROACHMENT AREA OF PROPOSED DWELLINGREQUIRING CONSENT TO BUILD WITHIN SETBACK.

OUTLINE OF EXISTING REAR STRUCTURE SHOWNFOR COMPARISON OF EXISTING AND PROPOSED.

N

2 PROPOSED SOUTH-WEST ELEVATION (STUDIO)1:100

BOUN

DARY

FENC

E

ENCROACHMENT AREA OF PROPOSED DWELLINGREQUIRING CONSENT TO BUILD WITHIN SETBACK.

PROPOSED NEW DETACHED STUDIO OUTLINEDBEYOND. NOTE- HIGHER GROUND BEYOND

JT + GL

FCS1

FCS2

FCS2FCS2WBD

WBDWBD

TIM1

TIM

1

FCS3

FCS3

TIM1

TIM

1

1700

FFL 6.50

FFL 9.55

FFL 6.50

FFL 9.55

2200

FFL 9.150

WBD

7700

7250

TIM1

FCS2

EXISTING WALLS TO BE RETAINEDSHOWN IN SOLID HATCH

EXISTING TO RETAINED SHOWN INGREY HATCH

LEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

TIM1

TIM1

4000

2400

FFL 9.150

Page 13: CLIENT: JT + GL PROJECT: PROPOSED ALTERATIONS + …

DWG NO:

REV:SCALE1:100 @ A3DATE

-

PROJECT NO.

COMPANY: FRECKLE ARCHITECTURE PTY LTDCONTACT: SHINAE VREDENBREGTPHONE: 0422 687 188EMAIL: [email protected]: PO BOX 762, OCEAN GROVE, VIC, 3226ABN: 95 638 677 184

1. BUILDER TO CHECK ALL DIMENSIONS BEFORECOMMENCING WORKS ON SITE

2. BUILDER TO REFER ANY DESCREPANCIES TOTHE ARCHITECT FOR CLARIFICATION.

3. DO NOT SCALE FROM DRAWINGS.4. ALL DIMENSIONS ARE STRUCTURAL.

DRAWINGPROPOSED ELEVATIONSPROJECT

CLIENT

TP.12

4 PROPOSED MAIN HOUSE NORTH- EAST ELEVATION (GARDEN)1:100

6 PROPOSED NORTH-WEST ELEVATION1:100

2021_038 CHESHUNT STREET, POINT LONSDALE

20.08.2021

FFLx 6.130

FFL 6.500

DRAFT ONLY. NOT FOR CONSTRUCTION.

B

GM

EM

TB

BOUN

DARY

FENC

E

BOUN

DARY

FENC

E

BOUN

DARY

FENC

E

FFL 9.150

OUTLINE OF EXISTING REAR STRUCTURE SHOWNFOR COMPARISON OF EXISTING AND PROPOSED.

EXISTING HOME SHOWN HATCHED GREY ASEXISTING CONDITIONS

NEW FIRST FLOOR DECK AND BALUSTRADE. COUNCIL CONSENT REQUIRED FOR AREAS OFENCROACHMENT WITHIN STANDARD BUILDINGREGULATION AND DESIGN DEVELOPMENTOVERLAY SIDE SETBACK LINE.

N

FFLx 6.130

5 PROPOSED STUDIO NORTH- EAST ELEVATION (GARDEN)1:100

EXISTING SINGLE STOREY DWELLING SHOWNOUTLINED BEYOND

OUTLINE OF EXISTING REAR STRUCTURE SHOWNFOR COMPARISON OF EXISTING AND PROPOSED.

FFL 6.500

JT + GL

1700

NEW BALUSTRADE OUTLINE BEYOND

DESIGN DEVELOPMENT OVERLAY MAXIMUMBUILDING HEIGHT RESTRICTION OF 8.5 METRESSHOWN ABOVE NATURAL GROUND LINE.

OUTLINE OF EXISTING REAR STRUCTURE SHOWNFOR COMPARISON OF EXISTING AND PROPOSED.TIM1

WBD

TIM1

FCS1

FCS2BRK1

FCS2

FCS2

WBD

FFL 9.150

BRK1

FCS3

FFL 9.55

NON HABITABLE WINDOW

2200

EXISTING WALLS TO BE RETAINEDSHOWN IN SOLID HATCH

EXISTING TO RETAINED SHOWN INGREY HATCH

LEGENDACU AIR-CONDITIONING EXTERNAL

UNITCP COMMUNICATIONS PITDR DRAINHWex HOT WATER UNIT EXISTINGEM ELECTRICAL METEREP ELECTRICAL POLE

EPt ELECTRICAL PITEOH ELECTRICAL OVERHEAD LINEFFLx FINISHED FLOOR LEVEL

EXISTINGFFL FINISHED FLOOR LEVELGM GAS METERHP HYDRONIC HEATING PANELHW HABITABLE WINDOW

HWS HOT WATER SERVICEMH MAN HOLENHW NON-HABITABLE WINDOWSLex SKYLIGHT EXISTINGSL SKYLIGHT PROPOSEDSP SEWER PITSRZ STRUCTURAL ROOT ZONET.01 TREE No.1

TP TELSTRA PITTPZ TREE PROTECTION ZONEWM WATER METERWT WATER TAP

3900

3700

7600

3900

2400

1300

7600

1300

2400

4000

7700

5800

1450

1450

6200

FFL 9.550