click to edit master subtitle style chapter 3: networking topologies, connectors and wiring...
TRANSCRIPT
![Page 1: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/1.jpg)
• Click to edit Master subtitle style
Chapter 3: Networking Topologies, Connectors and Wiring StandardsInstructor:
![Page 2: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/2.jpg)
Chapter 3: Objectives3.1 Categorize standard media types and associated
properties.
Fiber:
• Multimode• Singlemode
Copper:• UTP• STP• CAT3• CAT5• CAT5e• CAT6• CAT6a• Coaxial• Crossover• T1 Crossover• Straight-through
2
![Page 3: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/3.jpg)
Chapter 3 Objectives (cont.)
• Media converters:– Singlemode fiber to Ethernet
– Multimode fiber to Ethernet
– Fiber to Coaxial
– Singlemode to multimode fiber
• Distance limitations and speed limitations• Broadband over powerline
3.2 Categorize standard connector types based on
network media.• Fiber:
– ST
– SC
– LC
– MTRJ
3
![Page 4: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/4.jpg)
Chapter 3 Objectives (cont.)• Copper:
– RJ-45
– RJ-11
– BNC
– F-connector
– DB-9 (RS-232)
– Patch panel
– 110 block (T568A, T568B)
3.8 Identify components of wiring distribution.• IDF• MDF• Demarc• Demarc extension• Smart jack• CSU/DSU
4
![Page 5: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/5.jpg)
Physical Media
5
Let’s take a look at the three types of popular cables used in modern networking designs: – Coaxial– Twisted pair– Fiber optic
![Page 6: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/6.jpg)
Coax
6
• Coaxial cable, referred to as coax, contains a center conductor made of copper that’s surrounded by a plastic jacket with a braided shield over it.
• A plastic such as polyvinyl chloride (PVC, commonly known as Teflon) covers this metal shield.
• The Teflon-type covering is frequently referred to as a plenum-rated coating, and it’s often mandated by local or municipal fire code when cable is hidden in walls and ceilings.
![Page 7: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/7.jpg)
Thinnet Coax
7
![Page 8: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/8.jpg)
BNC Connectors
8
![Page 9: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/9.jpg)
Twisted-Pair Cable
9
• Twisted-pair cable consists of multiple individually insulated wires that are twisted together in pairs.
• Sometimes a metallic shield is placed around them; hence the name shielded twisted-pair (STP).
• Cable without outer shielding is called unshielded twisted-pair (UTP), and it’s used in twisted-pair Ethernet (10Base-T, 100Base-TX, 1000Base-TX) networks.
• So why are the wires in this cable type twisted? Because when electromagnetic signals are conducted on copper wires in close proximity—like inside a cable—it causes interference called crosstalk. Twisting two wires together as a pair minimizes interference and even protects against interference from outside sources.
![Page 10: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/10.jpg)
Unshielded Twisted-pair
10
This cable type is the most common today for the following reasons:
• It’s cheaper than other types of cabling.• It’s easy to work with.• It allows transmission rates that were impossible
10 years ago.• UTP cable is rated in these categories:
– Cat1– Cat2– Cat3– Cat4– Cat5– Cat5e– cat6
![Page 11: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/11.jpg)
Cat 5e UTP Cable
11
![Page 12: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/12.jpg)
RJ Connectors
12
![Page 13: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/13.jpg)
Fiber Optic
13
• Because fiber-optic cable transmits digital signals using light impulses rather than electricity, it’s immune to EMI and RFI.
• The cable itself comes in either single-mode fiber (SMF) or multimode fiber (MMF); the difference between them is in the number of light rays (the number of signals) they can carry. Multimode fiber is most often used for shorter-distance applications and single-mode fiber for spanning longer distances.
![Page 14: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/14.jpg)
Fiber Optic
14
Although fiber-optic cable may sound like the solution to many problems, it has pros and cons just like the other cable types.
Here are the pros:• Is completely immune to EMI and RFI• Can transmit up to 40 kilometers (about 25 miles)
And here are the cons:• Is difficult to install• Is more expensive then twisted-pair• Troubleshooting equipment is more expensive then
twisted-pair test equipment• Is harder to troubleshoot
![Page 15: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/15.jpg)
ST Connector Examples
15
![Page 16: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/16.jpg)
SC Connector Examples
16
![Page 17: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/17.jpg)
MT-RJ and LC Fiber Connectors
17
![Page 18: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/18.jpg)
Media Converters
![Page 19: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/19.jpg)
Media Converters (Cont.)
![Page 20: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/20.jpg)
Broadband over Power Line
![Page 21: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/21.jpg)
Serial Cables
![Page 22: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/22.jpg)
Universal Serial Bus
![Page 23: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/23.jpg)
Cable Properties
•Transmission Speeds
•Distance
•Duplex
•Noise Immunity (Security, EMI)
•Frequency
![Page 24: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/24.jpg)
Wiring Standards
24
There are different types of Ethernet wiring standards available:
• Straight-through cable (586A)• Crossover cable (586B)• Rolled cable (rollover)• Hardware loopback
![Page 25: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/25.jpg)
568A vs. 568B
25
568A+568A = straight through568B+568B = straight through568A+568B = crossover
![Page 26: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/26.jpg)
Straight-through Ethernet Cable
26
![Page 27: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/27.jpg)
Crossover Cable
27
![Page 28: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/28.jpg)
Rollover/Rolled Cable
28
![Page 29: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/29.jpg)
T1 Crossover Cable
29
![Page 30: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/30.jpg)
Installing Wiring Distributions
30
• MDF/IDF
• 25 Pair
• 110 Block
• Demarc/Demarc Extension
• Smart Jack
![Page 31: Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649da15503460f94a8ccd6/html5/thumbnails/31.jpg)
Summary
31
• Summary
• Exam Essentials Section
• Written Labs
• Review Questions