clear as the light of day: energy and more! · representations abroad africa angola egypt...

4
www.hensel.in Representations abroad Africa Angola Egypt Mozambique South Africa America Argentina USA Asia Bangladesh Bhutan Cambodia Georgia India Indonesia Kazakhstan Malaysia Maldives Myanmar Pakistan China Philippines Singapore South Korea Sri Lanka Taiwan Thailand Europe Austria Belgium Bulgaria Croatia Czech Republic Denmark Estonia Finland France Great Britain Greece Hungary Iceland Ireland Israel Italy Latvia Lithuania Luxembourg Montenegro Netherlands Norway Poland Portugal Romania Russia Serbia and Slovakia Spain Sweden Switzerland Turkey Ukraine Middle East United Arab Emirates Bahrain Iran Kuwait Oman Qatar Saudi Arabia Oceania Australia New Zealand Clear as the light of day: Energy and More! Photovoltaic Plants RF CO ORDINATOR MODBUS RTU FRONT END SMU 8/12/14/16/20/24 Customised solutions with String Monitoring String Monitoring solution for power plants with RS485 String Monitoring solution for power plants with RF Hensel Electric India Pvt. Ltd. Industrial Electrical Power Distribution Systems 35 Kunnam Village, Sunguvarchathram Walajabad Road Sriperumbudur - 631 604 Kanchipuram Dist., Tamil Nadu INDIA Phone: +91-44-3727 0202 Fax: +91-44-3727 0200 E-Mail: [email protected] www.hensel.in Technical Specifications & Features Individual Channel current measurement using Hall sensors for up to 24 PV strings Nominal current in each string 0-25A, maximum 30A Accuracy ±1% operating throughout the range Maximum current in each independent string is ± 30A Isolated DC power supply for the card through DC/DC converter DC Bus Voltage measurement range 0 - 1200V DC Calculated power measurements for each string (Optional) Temperature Measurements On board temperature sensor for measuring enclosure inside temperature 0-125 deg C 2 number of PT-100 inputs for measuring the external PV panel temperatures PT100 measurement range -40 to 160 deg C (0-160 deg nominal, -40 deg C optional) Accuracy of temperature measurements ± 2DegC Digital I/O Isolation Voltage (2.5KV) / Status input Voltage of 24V/48V DC Electrical Parameters Input Auxiliary DC power supply 24V DC @200mA (18 to 36V DC) AC input power supply (Optional) Transient voltage protection for the RS-485 ports Recommended surge suppression – 1000V, Class II, 40KA for DC bus bar Recommended surge suppression – 24V, Class II, 20KA for RS485 Communication Parameters RS485 isolated port for data communication using 2-wire half duplex communication RF-Mesh network communication module (Optional) Configurable Band rates from 1200 bps to 115200 bps Default and recommended communication band rate is set at 9600bps Communication Protocol MODBUS-RTU on RS-485 port Up to 100 SMU cards can be multi-dropped on RS485 network without any repeater SMU 8/12/14/16/20/24 FRONT END

Upload: lyliem

Post on 19-Aug-2019

218 views

Category:

Documents


0 download

TRANSCRIPT

www.hensel.in

Representations abroad

Africa

AngolaEgyptMozambiqueSouth Africa

America

ArgentinaUSA

Asia

BangladeshBhutan CambodiaGeorgiaIndiaIndonesiaKazakhstanMalaysiaMaldivesMyanmarPakistan

ChinaPhilippines SingaporeSouth KoreaSri LankaTaiwan Thailand

Europe

AustriaBelgiumBulgariaCroatiaCzech Republic DenmarkEstonia

FinlandFranceGreat BritainGreeceHungaryIcelandIrelandIsraelItalyLatviaLithuaniaLuxembourgMontenegroNetherlands NorwayPolandPortugalRomaniaRussiaSerbia andSlovakiaSpainSwedenSwitzerlandTurkeyUkraine

Middle East

United Arab Emirates BahrainIranKuwaitOmanQatarSaudi Arabia

Oceania

AustraliaNew Zealand

Clear as the light of day: Energy and More!Photovoltaic Plants

RF

CO ORDINATOR

MODBUS

RTU

FRONT END

SMU

8/12/14/16/20/24

Customised solutions with String Monitoring

String Monitoring solution for power plants with RS485

String Monitoring solution for power plants with RF

Hensel Electric India Pvt. Ltd.Industrial Electrical Power Distribution Systems

35 Kunnam Village, Sunguvarchathram Walajabad RoadSriperumbudur - 631 604Kanchipuram Dist., Tamil NaduINDIA

Phone: +91-44-3727 0202Fax: +91-44-3727 0200E-Mail: [email protected]

Technical Specifications & FeaturesIndividual Channel current measurement using Hall sensors

for up to 24 PV strings

Nominal current in each string 0-25A, maximum 30A

Accuracy ±1% operating throughout the range

Maximum current in each independent string is ± 30A Isolated DC power supply for the card through DC/DC converter

DC Bus Voltage measurement range 0 - 1200V DC

Calculated power measurements for each string (Optional)

• • •

• •

Temperature MeasurementsOn board temperature sensor for measuring enclosure

inside temperature 0-125 deg C

2 number of PT-100 inputs for measuring the external PV panel temperatures

PT100 measurement range -40 to 160 deg C (0-160 deg nominal, -40 deg C optional)

Accuracy of temperature measurements ± 2DegC Digital I/O

Isolation Voltage (2.5KV) / Status input Voltage of 24V/48V DC

Electrical ParametersInput Auxiliary DC power supply 24V DC @200mA (18 to 36V DC)

AC input power supply (Optional)

Transient voltage protection for the RS-485 ports

Recommended surge suppression – 1000V, Class II, 40KA for DC bus bar

Recommended surge suppression – 24V, Class II, 20KA for RS485

• • • • •

Communication ParametersRS485 isolated port for data communication using 2-wire

half duplex communication

RF-Mesh network communication module (Optional)

Configurable Band rates from 1200 bps to 115200 bps

Default and recommended communication band rate is set at 9600bps

Communication Protocol MODBUS-RTU on RS-485 port

Up to 100 SMU cards can be multi-dropped on RS485 network without any repeater

• • • • •

SMU

8/12/14/16/20/24

FRONT END

Protective device

with String monitoring Suitable for armoured cables accordingto British Standard

Connection of geneDisconnection switch

DC String Combiner Box Fused up to 1000V

Ideal for commercial PV systems of 3 and 4 string design, the PV combiner box from IPD provides overcurrent protection as well as DC isolation. Fitted with the latest Telergon DC isolator this 4-string combiner is easy to install and quick to connect.

Switching Designed around the latest high current DC switch from Telergon, ZFV55, the IPD combiner box includes multiple knock-out entries as well as high UV stability. The ZFV55 is tested to meet the latest International Standard IEC 60947.3 with switching capability of DC21B. The ZFV55 complies with the requirements of AS5033 2014.

Overcurrent The Mersen PV fuse links used in this combiner box are tested to the latest fuse Standard IEC 60269.6. This Standard was released in 2011 and is specifically included in the fuse standard to test the cyclic loading and long term reliability of fuses when used in photovoltaic systems.

Enclosure The high-quality Hensel enclosure products are made of material that is UV, impact, dust and waterproof, self-extinguishing, flame-retardant, halogen and silicone-free. This product and quality philosophy has made Hensel the world Number 1 brand for electrical distribution solutions in difficult environments

A = DC String Combiner boxes

B = AC String Inverter Panels C = AC Distribution Panels D = AC Grid Protection Panels

Note: Available with optional Dehn Photovoltaic surge protection on request, ask your local IPD rep for details.

Features:-

Description: Small DC String combiner box including Overcurrent and DC isolation functions. Optional Surge protection.

Application: PV string protection and isolation.

Certification: International Electrotechnical Commission IEC 60947.3, IEC 60269.6, IEC 529

Number DC

Strings

Max

Voltage

Surge

Protection

Catalogue

Number

4 1000V DC

- PVDC041

4 Included PVDC41/S

Notes: For the requirements of AS 5033 2012 Appendix B, with 2x contacts in series in Positive (+) and 2x contacts in series in the negative (-):-

900V Voc string, 4 x strings with Isc max of 8.9A (before Table 4.2 of AS 5033 2014)

1000V Voc string, 3 x Strings with Isc max of 8.9A (before Table 4.2 of AS 5033 2014)

Voc string = Voc ARRAY + Yv x Tmin x TSTC x M (as per Clause 4.2 of AS5033 2014).

Circuit

Dimensions

Spec Sheet: DC combiner Box

Grid Customers MSBD

Up to 4 strings inputs

Inverter

Knock-Outs/Entries

10 x M20 28 x M25 2 x M32/40 6 x M40/50

Optional Grid

Protection