clean room labs start this week lectures will only be on tuesday until further notice lectures will...
TRANSCRIPT
Clean Room Labs Clean Room Labs Start this weekStart this week
•Lectures will only be on Tuesday Lectures will only be on Tuesday
until further noticeuntil further notice•You will meet in the Cameron clean You will meet in the Cameron clean room at your Team designated timeroom at your Team designated time
•Do not miss a Clean Room labDo not miss a Clean Room lab•If you do miss a clean room lab, you If you do miss a clean room lab, you can attend another team’s time to can attend another team’s time to
get caught upget caught up
CAMERON Hall CAMERON Hall formerly know as Cameron Applied research formerly know as Cameron Applied research
Center (CARC)Center (CARC)
Craver Craver RoadRoad
Main Entrance Main Entrance The clean room is just at the top of the stairs The clean room is just at the top of the stairs
Side entrance – Second FloorSide entrance – Second FloorThe clean room is just inside these doorsThe clean room is just inside these doors
Second floor rear entrance Second floor rear entrance to Cameron to Cameron
The clean room is in the opposite corner The clean room is in the opposite corner from this entrance, on the same floorfrom this entrance, on the same floor
Main viewing window into Main viewing window into the clean roomthe clean room
Door to Door to clean clean
room is room is herehere
Enter the clean room Enter the clean room gowning area – The TA will gowning area – The TA will
let you inlet you in
Door to the clean roomDoor to the clean room
Remove coats, hats, back packs, Remove coats, hats, back packs, etc. and prepare to put on the etc. and prepare to put on the
clean room garments clean room garments
Following the TA’s Following the TA’s instructions – put on the instructions – put on the
clean room garmentsclean room garments
Sign in sheet is located on wire table inside the garment Sign in sheet is located on wire table inside the garment change roomchange room
Be sure to sign in – credit for attending the clean room Be sure to sign in – credit for attending the clean room sessions are taken from the sign in sheetsessions are taken from the sign in sheet
Locate and Locate and understand understand how to use how to use the safety the safety apparatusapparatus
Each team will receive a wafer Each team will receive a wafer box and 8 100mm silicon box and 8 100mm silicon
waferswafers
Special Special tweezers tweezers
are used to are used to handle handle silicon silicon waferswafers
Engr 1202 ECE LabEngr 1202 ECE LabMicro Planar Antenna TravelerMicro Planar Antenna Traveler
OPERATION DATE DATE DATE DATE DATE DATE DATE DATE PROCESSNAME WF 1 WF 2 WF 3 WF 4 WF 5 WF 6 WF 7 WF 8 DESCRIPTION
Starting Material Silicon 100mm or other substrateClean Clean H2O2 / H2SO4 2:3 for 10 min Use 100ml:150ml for single wafer Rinse - DIH2O - 5 min minimum
Dip - 10:1 - DIH2O/HF - 10 secRinse - DIH2O - 15 minutes max Record resistivity ______________Dry - Rinser/Dryer - Dry only cycle
Dielectric Formation Use 1100C oxidation furnace # 6 Load wafers, N2 running
5' N2 to stabilize temperature5' N2 + O230' N2 + O2 + H2 (steam)5' N2 + O2Unload, N2 running
Deposit Conductor Conductor material ____________________Load conductor if necessary. Record machine name/number _________Start pump down cycle Record time at start _____________Begin deposition Record pressure at start _____________Record final thickness ____________AVent chamber and unload wafers
Create Mask Create autocad drawingArray drawing and print directly on to ink-jet transparency
Trim Mask Trim mask to about 105 mm diameterConductor Spin photoresist - 60 sec @ 4K rpm - Microposit 1813 photoresist Photolithography Soft bake - 60 sec hotplate @ 115C
Align - align wafer flat to stop on wafer chuckCheck mask aligner UV lamp intensityExpose - typical 10-15 sec.Develop - use either spray developer or manual developingInspect - lab manager or TA Strip PR and repeat if necessaryHard bake - 10' @ 90C (optional)
Conductor Etch Etch with appropriate etch solution. Record etch solution _____________Rinse in DIH2O for 10 minDry - Rinser/Dryer - Dry only cycle
Inspect - lab manager or TAPR strip 5' Acetone + 5' Methanol + 5' DIH2o rinse + N2 dryDice Saw cut with microautomation 1100 diamond saw Clean and dry
Homework AssignmentHomework Assignment
1.1. Meet as a teamMeet as a team2.2. Select a team leaderSelect a team leader3.3. Use the form listed for Assignment #6Use the form listed for Assignment #64.4. Record members in attendance and time Record members in attendance and time
of meetingof meeting5.5. Decide on application, Cellular, Decide on application, Cellular,
Bluetooth/Wi-Fi, RFIDBluetooth/Wi-Fi, RFID6.6. Team leader to e-mail me with the time of Team leader to e-mail me with the time of
meeting, team members in attendance, meeting, team members in attendance, and your team’s choice of applicationand your team’s choice of application
7.7. Preliminary choice - can be changed laterPreliminary choice - can be changed later