classroom & conference cleaning - global industrial
TRANSCRIPT
Classroom & Conference Cleaning
COST-EFFECTIVE EASY-TO-USEPOWERFUL
✓ Powerful
XPOWER’s Ozone Generator has a powerful extended airflow specifically suited to quickly cover large areas (up to 2,000 ft2) in minimal time.
✓ Technological Design
The combination of air mover and commercial ozone generator are the critical components designed to increase air flow to maximize efficiency in generating ozone gas.
✓ Refresh the Air
The Air Mover replaces stale air and bad odors with fresh air post-Ozone Treatment to provide for a clean environment.
XPOWER’s Ozone
Generator helps disinfect
your classrooms and
conference rooms to
keep people safe.
XPOWER Ozone Generator
M-25 & M-27
• High concentrations of ozone gas capable of killing microorganisms like bacteria, fungus mold, and viruses.
• Integrated axial air mover increases efficiency of ozone generator and delivers O3 quickly and evenly across large areas.
• Timer for easy, hands-off usage. We recommend it to be set for 1-2 hours for treatment.
• Speed control for air mover that can also operate as a ventilator to help reduce ozone concentration to safe levels.
The Technology
Timer Speed Control
What To Know About
Ozone Generator Use
• PLEASE NOTE: Ozone Treatment must occur in enclosed spaces. The treatment can only take place when PPP are removed from the space: People, Pets, and Plants.
• An ozone concentration above 2 ppm is sufficient for sanitation.1
• After the Ozone Treatment, you can use an ozone meter to measure safe levels of ozone (below 0.2 ppm), typically around 10 minutes after treatment depending on the size of your space.2
1. Source: Dubuis ME, Dumont-Leblond N, Laliberté C, Veillette M, Turgeon N, Jean J, Duchaine. “Ozone efficacy for the control of airborne viruses: Bacteriophage and norovirus models.” 2020, PLoSONE 15(4): e0231164. https://doi.org/10.1371/journal.pone.0231164 Accessed 27 Apr. 2020.
2. Source: Occupational Safety and Health Administration (OSHA), OSHA Occupational Chemical Database, https://www.osha.gov/chemicaldata/chemResult.html?RecNo=9.
Examples of Ozone Meters
The Air Mover increases the air flow provided to the Generator. This allows the Generator to produce a greater amount of ozone
particles to be distributed throughout the space.
Increased Air Flow → Increased Efficiency
How To Use
Ensure the space is empty of people, pet, and plants to begin operating the Ozone Treatment Safely.
Turn on the machine to start the Ozone Treatment
Turn the air mover speed to maximum or according to the
size of space.
Turn on the Ozone generator
Set the timer according to the
size of your space
a. b. c.
Ozone levels should be built to a concentration of 2-4 PPM in order to effectively sanitize
1.)
2.)
How To Use
Ozone levels will naturally dissipate to safe levels (<0.2 PPM) automatically after 10 minutes of shutting down ozone generator.
Eliminate odors, freshen indoor air and ventilate spaces by opening doors and windows while directing air outward with our Axial Air Mover with Ozone Generator set to off.
Once ozone treatment is complete, please store unit in a safe place for future use.
3.)
4.)
5.)
Example Spaces Size Tools Treatment Time
Seminar Room 300 sq ft M-25 (5g)
Ozone 60 min
Clean Air 30 min
Total 90 min
Conference Room 600 sq ft M-25 (5g)
Ozone 90 min
Clean Air 30 min
Total 120 min
Lecture Hall 1,000 sq ft M-27 (10g)
Ozone 90 min
Clean Air 30 min
Total 120 min
Ampitheatre 2,000 sq ft 2 x M-27 (10g)
Ozone 120 min
Clean Air 30 min
Total 150 min
What will my space need?