CITY ENGINEERING CONSULTANTS.
Project -
Plot No # 1096, Sector # South, Area # Al - Rawdha 2
01 to 07 Architectural Drawings
08 to 15
Sewerage / Water Supply 16 to 19
Structural Drawings
20 to 22 General Notes
CONSULTING ARCHITECTS & ENGINEERSTEL. 06-7473399, FAX 06-7473393, E-mail : [email protected]
OWNER :
Proposed Building Ground Floor
L.L.C
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA
JABBAR MAHMOUD SHAQALAIH
PROPOSED BUILDING GROUND FLOOR
R O A D
P L O T
P
L
O
T P
L O T
300 2400 300
3000 cm
30
00
cm
30
02
70
0
TEMPORARY FENCING LAYOUTSCALE - 1 : 100
LOCATION PLANN.T.S
1096
1094
R O A D
1093
1092
1098
10991095
510
PUMP Rm TELE.Rm
200
170
200
200
TEMPORARY FENCING LAYOUT
1:100 01
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
100
Alum
inum
she
et22
0
Steel pipe
Steel pipe
Concrete Blocks
Elevation
Section
TEMPORARY FENCING LAYOUT
UNDER GROUND WATER TANK
TOTAL 8,000 GALS CAPACITY
3000 GALS FOR FIRE USE
5000 GALS FOR DOMESTIC USE
ELEC.ROOM
220
400
TRANSFORMER ROOM
2500
PROPOSED BUILDING GROUND FLOOR
R O A D
P L O T
P L
O
T P
L O T
300 2400 300
3000 cm
30
00
cm
30
02
70
0
15
0
SETTING OUT PLANSCALE - 1 : 100
LOCATION PLANN.T.S
1096
1094
R O A D
1093
1092
1098
10991095
510
PUMP Rm
TELE.Rm200
170
200
200
SETTING OUT PLAN
1:100 02
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
1. This drawing is the copy right of CITY ENGINEERING
Consultants, Ajman, U.A.E. and must not be retained,
copied or used without the above consultants authority.
2. Do not scale the drawing for dimensions.
3. All dimensions are in centimeters, unless otherwise
specified. All dimensions to be verified on site and
approved by the consultants engineer.
4. The Contractor should read all the drawings thoroughly
before proceeding the works. If any discrepancy with the
relevant drawing, they should brought the notice to the
consultant immediately.
GENERAL NOTES.
AREA DETAILS:- Ground Floor Building
Ground Floor
SQMT. FLOORS
TOTAL ( AREA )
Tower FloorUNDER GROUND WATER TANK
TOTAL 8,000 GALS CAPACITY
3000 GALS FOR FIRE USE
5000 GALS FOR DOMESTIC USE
400
ELEC.ROOM
220
TRANSFORMER ROOM
400
6 cm thick interlock Red colour
UPSTAND CURB STONE
8 cm thick interlock
Gray colour
8 cm thick interlock
Gray colour
FLUSH CURBFLUSH CURBFLUSH CURB
UPSTAND CURB STONE
20
06
00
80
0
SEP
TIC N
o # 6
TAN
K
SW.
GROUND FLOOR PLAN
1:100 03
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
SHOP : 5 Nos
DOUBLE BED ROOM FLAT : 2 Nos
WATCH MAN ROOM
SINGLE BED ROOM FLAT : 2 Nos
BED ROOM
BED ROOM
LIVING ROOM
TOILETTOILET
BED ROOM
BED ROOM
LIVING ROOM
KITCHEN
TOILET TOILET
TOILET TOILET
KITCHEN
BED ROOM
LIVING ROOM
TOILETTOILET
KITCHEN
BED ROOM
LIVING ROOM
220
1
2 3
4
FIRE CAB.
LIFT
485
355
355
485
170
205
305360
540
360
540
485
360
480
350
225
370
350
560
320
475 205
190
200
190
170
200
170
240
170
240
330
350
530
260
250
170 240
190
240
190
240
215
KITCHEN
305
230
380350360380
400
390
690
910
510
PUMP Rm TELE.Rm
ELEC.ROOM
SHOP # 3SHOP # 2 SHOP # 4 SHOP # 5
SHOP # 1
155200
170
200
300
215
UP
120
120
WATCH MAN ROOM
295
TOILET
GROUND FLOOR PLANSCALE - 1 : 100
12023
0
230
120
240
190
260 190
180
200
A/W
A/W A/W
A/W
910
910
910
200
530
A A
P
A
S
S
A
G
E
120 120(for future)
GD1/FG LD
LD1
LD1
LD1
MD
D
DD
D D
FD
D1
D1
D1
D2
D2
D2 D2
D2
D1D1
D1
D1 D1
D1
D1
D1
D1
D2
V
V
V
V V
V
V
V
V
W
W
W W
W
W
W
W1
W2W2
W2 W2
167.50 150 167.50
105
150
100
65 100 140 140 100 65 167.50 150 167.50
100
150
100
9515
075
100
150
100
2512
040
10
8015
080
150
190 50
140
5070
245
355
185
880
990
B
B
185
160
UNDER GROUND WATER TANK
TOTAL 8,000 GALS CAPACITY
3000 GALS FOR FIRE USE
5000 GALS FOR DOMESTIC USE
220
TOILETPANTRYD2
V
D2
325
WW
W
9515
095
D2
740
100
11030
010
015
1516
515
1517
015
1547
5
172 15 15 168 45 15 15 125 95 15 15 205 15 15 115 110 15 15 50 163 15 15 173
475
1515
175
1515
165
1515
11015
1525
100
3515
8095
100
590
150110
1 2 3 4 6 7 8 9 10 11 125
A
C
D
F
G
H
J
I
K
E
B
10 410 85 315 50 210 120 120 260 315 75 420 10
240010
370
260
110
330
120
125
120
80
235
360
110
10
27
00
155
O
L
M
N
85
220
400
140
180
+30 CM LVL +30 CM LVL +30 CM LVL +30 CM LVL +30 CM LVL +30 CM LVL
+30 CM LVL
+30 CM LVL
+30 CM LVL
+150 CM LVL
+150 CM LVL
+7
5 C
M LV
L
GD1/FG GD1/FG GD1/FG GD1/FG
DESCRIPTION
PROTECTION ALUMINIUM GRILL & COLOUR APPROVED BY OWNER.
ALL ALUMINIUM WINDOWS SHOULD BE POWDER COATED REFLECTED GLASS WITHNOTE
SILL
SCHEDULE OF DOOR & WINDOWS
SIZETYPE
-----300 x 220MD1
ALUM. LOUVER DOUBLE LEAF HINGED DOOR.300 x 280LD -----
100W 150 x 120 ALUMINIUM GLAZED SLIDING WINDOW AS / ELEVATION
100W1 120 x 120
ALUMINIUM GLAZED HINGED WINDOW WITH FIXED GLASS & EXHAUST FAN
ALUMINIUM GLAZED DOUBLE LEAF HINGED DOOR & BOTH SIDE & TOP FIXED GLASS AS PER ELEVATION.SEE DETAILSGD/FG -----
110W2 100 x 70+ 40 ALUMINIUM GLAZED SLIDING WINDOW WITH 40cm H FIXED GLASS AS PER ELEVATION
ALUMINIUM GLAZED DOUBLE LEAF HINGED DOOR &
BOTH SIDE FIXED GLASS AS PER ELEVATION.
ALUM. LOUVER SINGLE LEAF HINGED DOOR.100 x 210LD1 -----
FD 100 x 210 SOLID CORE TEAK WOOD FIRE RESISTANT (2 HOURS) SINGLE LEAF DECOR DOOR-----
100 x 210D SOLID CORE TEAK WOOD FIRE RESISTANT (1HOURS) SINGLE LEAF DECOR DOOR
100 x 210D1 SOLID WOOD SINGLE LEAF DECORE DOOR .
80 x 210D2 SOLID WOOD SINGLE LEAF DOOR WITH FARAMIC COVERING.
-----
-----
-----
ALUMINIUM GLAZED SLIDING WINDOW AS / ELEVATION
V 50 x 40+30 160
7060
340
70
110
120
D2
120
6070
400
+30 CM LVL
TRANSFORMER ROOM
180
110
120
90
90 150 108
25
103 150 105
TOWER FLOOR PLAN
1:100 04
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
LIFT
UP
120
120
28
50
58
0
280
240
DN
190
180
TOWER FLOOR PLANSCALE - 1 : 100
A A
120
230
120
230
(for future)
B
B
D
120 120
SLOPE 1 : 90SLOPE 1 : 90
SLOPE 1 : 90 SLOPE 1 : 90
1 2 3 4 6 7 8 9 10 11 125
A
C
D
F
G
H
J
I
K
E
B
10 410 85 315 50 210 120 120 260 315 75 420 10
2400
10
370
260
110
330
120
125
120
80
235
360
110
10
27
00
155
O
L
M
N
85
220
DESCRIPTION
PROTECTION ALUMINIUM GRILL & COLOUR APPROVED BY OWNER.
ALL ALUMINIUM WINDOWS SHOULD BE POWDER COATED REFLECTED GLASS WITHNOTE
SILL
SCHEDULE OF DOOR & WINDOWS
SIZETYPE
-----300 x 220MD1
ALUM. LOUVER DOUBLE LEAF HINGED DOOR.300 x 280LD -----
100W 150 x 120 ALUMINIUM GLAZED SLIDING WINDOW AS / ELEVATION
100W1 120 x 120
ALUMINIUM GLAZED HINGED WINDOW WITH FIXED GLASS & EXHAUST FAN
ALUMINIUM GLAZED DOUBLE LEAF HINGED DOOR & BOTH SIDE & TOP FIXED GLASS AS PER ELEVATION.SEE DETAILSGD/FG -----
110W2 100 x 70+ 40 ALUMINIUM GLAZED SLIDING WINDOW WITH 40cm H FIXED GLASS AS PER ELEVATION
ALUMINIUM GLAZED DOUBLE LEAF HINGED DOOR &
BOTH SIDE FIXED GLASS AS PER ELEVATION.
ALUM. LOUVER SINGLE LEAF HINGED DOOR.100 x 210LD1 -----
FD 100 x 210 SOLID CORE TEAK WOOD FIRE RESISTANT (2 HOURS) SINGLE LEAF DECOR DOOR-----
100 x 210D SOLID CORE TEAK WOOD FIRE RESISTANT (1HOURS) SINGLE LEAF DECOR DOOR
100 x 210D1 SOLID WOOD SINGLE LEAF DECORE DOOR .
80 x 210D2 SOLID WOOD SINGLE LEAF DOOR WITH FARAMIC COVERING.
-----
-----
-----
ALUMINIUM GLAZED SLIDING WINDOW AS / ELEVATION
V 50 x 40+30 160
A/W A/W
A/W
A/W
260
180 240
190
630
FRONT ELEVATION & SECTION@A-A & B-B
1:100 05
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
FR0NT ELEVATIONSCALE - 1 : 100
3053
51
20
68
5
LEGEND
1 EPOXY PAINT - COLOUR 1 - EXTERNAL WALLS
FINISHING DETAILS
-2.5CM THICK PLASTERING DECORE WORK3
EPOXY PAINT - COLOUR 2( FOR PROJECTION & WINDOW FINS )2
POWDER COATED ALUMINIUM DECORE RAILING 4
GRANITE TREAD & RISERS5
DECORE STONE WORK6
38
0
WATCH MAN ROOMTOILET
10CM THICK P.C.C OVER 1000GUAGE POLYTHENE SHEET
CERAMIC TILES
COMPACTED EARTH FILLING
SECTION @ A-ASCALE - 1 : 100
CEMENT SAND SCREED LAID TO SLOPE
TORCH APPLIED BITUMAT POLYBOND -4mm THICK ON BITUMAN PRIMER
RCC SLAB AS PER STRUCTURAL DRAWING
WHITE CEMENT TILES
100 cm Alum. HandRail
TREAD : 30.00 cmRISER : 17.29 cm
535
21
03
25
12
0
SHOP # 4
P A S S A G E
CEMENT SAND SCREED LAID TO SLOPE
TORCH APPLIED BITUMAT POLYBOND -4mm THICK ON BITUMAN PRIMER
RCC SLAB AS PER STRUCTURAL DRAWING
WHITE CEMENT TILES
LIVING ROOM
305
35
12
0
10CM THICK P.C.C OVER 1000GUAGE POLYTHENE SHEET
CERAMIC TILES
COMPACTED EARTH FILLING SECTION @ B-BSCALE - 1 : 100
SCALE - 1 : 20
PARAPET DETAIL
BEAM AS/SCH.
SLAB AS/SCH.
12
0
10
02
0
35
10
10
10
0
8 8
20
41
5
15
0
15
0
FUTU
RE LI
FT
41
5
28
02
55
12
0
GATE LVL
PLINTH LVL (+30 )
G.F SLAB LVL (+565 )
PARAPET LVL (+1015 )
TOWER SLAB LVL (+915 )
30
53
53
50
10
0
10
15
GATE LVL
PLINTH LVL (+30 )
G.F SLAB LVL (+565 )
PARAPET LVL (+1015 )
TOWER SLAB LVL (+915 )
30
53
53
50
10
0
10
15
GATE LVL
PLINTH LVL (+30 )
G.F SLAB LVL (+565 )
30
53
51
20
68
5
PARAPET LVL (+685 )
ALUMINIUM ROOF (FOR FUTURE LIFT ROOM)
TEMPRORARY
GYPSUM DECORE WORK7
7
6
5
2
1
1
2
2
2
ALUMINIUM ROOF (FOR FUTURE LIFT ROOM)
TEMPRORARY
30
53
51
20
68
5
RIGHT SIDE ELEVATIONSCALE - 1 : 100
REAR SIDE ELEVATIONSCALE - 1 : 100
LEFT SIDE ELEVATIONSCALE - 1 : 100
RIGHT ,LEFT & REAR SIDE ELEVATION
1:100 06
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
1
11
1
1
1
1
7
7
3
3
3
4
55
5
2
2
2
2
2
2
2
2
GATE LVL
PLINTH LVL (+30 )
G.F SLAB LVL (+565 )
PARAPET LVL (+1015 )
TOWER SLAB LVL (+915 )
15
04
15
35
01
00
10
15
GATE LVL
PLINTH LVL (+30 )
G.F SLAB LVL (+565 )
PARAPET LVL (+1015 )
TOWER SLAB LVL (+915 )
15
04
15
35
01
00
10
15
GATE LVL
PLINTH LVL (+30 )
G.F SLAB LVL (+565 )
PARAPET LVL (+1015 )
TOWER SLAB LVL (+915 )
15
04
15
35
01
00
10
15
100
100110
100
LEGEND
1 EPOXY PAINT - COLOUR 1 - EXTERNAL WALLS
FINISHING DETAILS
-2.5CM THICK PLASTERING DECORE WORK3
EPOXY PAINT - COLOUR 2( FOR PROJECTION & WINDOW FINS )2
POWDER COATED ALUMINIUM DECORE RAILING 4
GRANITE TREAD & RISERS5
DECORE STONE WORK6
GYPSUM DECORE WORK7
DOOR & WINDOW SCHEDULES
1:100 07
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
300
210
100
210
100
DOOR " D" DOOR " D1"
210
100
FIRE DOOR " FD"LOUVER DOOR " LD1 "
LOUVER DOOR " LD "GLAZED DOOR " GD/FG "MAIN DOOR " MD "
16
070
VENTILATOR " V"
50
22
0
60 180 60
300
28
0
210
100
10
0120
150
10
0120
120
11
07
040
100
WINDOW " W " WINDOW " W1 " WINDOW " W2 "
DESCRIPTION
PROTECTION ALUMINIUM GRILL & COLOUR APPROVED BY OWNER.
ALL ALUMINIUM WINDOWS SHOULD BE POWDER COATED REFLECTED GLASS WITHNOTE
SILL
SCHEDULE OF DOOR & WINDOWS
SIZETYPE
-----300 x 220MD1
ALUM. LOUVER DOUBLE LEAF HINGED DOOR.300 x 280LD -----
100W 150 x 120 ALUMINIUM GLAZED SLIDING WINDOW AS / ELEVATION
100W1 120 x 120
ALUMINIUM GLAZED HINGED WINDOW WITH FIXED GLASS & EXHAUST FAN
ALUMINIUM GLAZED DOUBLE LEAF HINGED DOOR & BOTH SIDE & TOP FIXED GLASS AS PER ELEVATION.SEE DETAILSGD/FG -----
110W2 100 x 70+ 40 ALUMINIUM GLAZED SLIDING WINDOW WITH 40cm H FIXED GLASS AS PER ELEVATION
ALUMINIUM GLAZED DOUBLE LEAF HINGED DOOR &
BOTH SIDE FIXED GLASS AS PER ELEVATION.
ALUM. LOUVER SINGLE LEAF HINGED DOOR.100 x 210LD1 -----
FD 100 x 210 SOLID CORE TEAK WOOD FIRE RESISTANT (2 HOURS) SINGLE LEAF DECOR DOOR-----
100 x 210D SOLID CORE TEAK WOOD FIRE RESISTANT (1HOURS) SINGLE LEAF DECOR DOOR
100 x 210D1 SOLID WOOD SINGLE LEAF DECORE DOOR .
80 x 210D2 SOLID WOOD SINGLE LEAF DOOR WITH FARAMIC COVERING.
-----
-----
-----
210
80
DOOR " D2"
ALUMINIUM GLAZED SLIDING WINDOW AS / ELEVATION
V 50 x 40+30 160
40
30
F.F.L
F.F.L
F.F.L
22
06
0
300
60 180 60
10
06
0
300
COLUMN AXIS LAYOUT
1:100 08
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
1 2 3 4 6 7 8 9 10 11 125
A
C
D
F
G
H
J
I
K
E
B
10 410 85 315 50 210 120 120 260 315 75 420 10
2400
10
370
260
110
330
120
125
120
80
235
360
110
10
27
00
COLUMN AXIS LAYOUTSCALE - 1 : 100
155
O
L
40
C1C2 C2 C4 6
0
C2 50
50
12.50
50
10
C2 C1 40
10
50
C2 C6
15
C630 70
C6
12.50
C6
80
15
C6
80
C2
50
N.C
10
10 C2
50
10
C2
50
10
50
C2
60
15
C5
15
C3 50
70
15
C670C7*C7 70
30
C6 70
C7
70
C7*
70
20C5 15
C3
50
40
15
C7C8
90
10
C645
C630
25
C7
60
15
10
10 N.CC5
60
1560
10
C5C6
70
C560 N.C
10
10
C1
40
15 C520
C2
50
10
60
10 C3 N.C
10
10
C6
70
15 C5
60
15
C5
15
60
C5
60
15
65
10C5
C515
60
190
18
0
C1*M
10
50
C2
25
10C2
60
10
C3C2*
C2
30
60
25
55
10
N
20
50
20
15
101010
15
50
106
51
5
15
10
10
10
15
5 30
15
15
10
15 10
15
15
10
70
15
15
15
10
15 20
10
30
20
15
10
50
1010 210
10 10
10
LEGGS
SCHEDULE OF COLUMNS
SIZE STEEL
C1
C3
TYPE STIRRUPS
C2
NC
T 8 mm @ 20 cm c / c16 T 16
REMARKS
20 x 20 4 T 16 T 8 mm @ 20 cm c / c 2 LEGGED
C5
25 x 60 6 LEGGED
C4
UP TO TIE BEAM LVL.
C6
20 x 50 10 T 16 T 8 mm @ 20 cm c / c 4 LEGGED
20 x 60 14 T 16 T 8 mm @ 20 cm c / c 6 LEGGED
6 LEGGEDT 8 mm @ 20 cm c / c14 T 1625 x 70
6 LEGGEDT 8 mm @ 20 cm c / c16 T 1625 x 70
6 LEGGEDT 8 mm @ 20 cm c / c20 T 1625 x 80
25
90
6 LEGGED COLUMN " C8 "SCALE: - 1 : 20
20 T 16
STIR
RU
PS
Y 8
@2
0 c
m c
/ c
STIRRUPS
4 T 16
Y 8 @20 cm c / c20
20
2 LEGGED COLUMN " N.C "Up to Tie Beam Lvl
T 8
mm
@ 2
0 c
m c
/ c
50
20
10 T 16
COLUMN " C1 "SCALE 1 : 20
4 LEGGED
STIR
RU
PS
STIR
RU
PS
14 T 16
Y 8
@2
0 c
m c
/ c
20
60
6 LEGGED COLUMN " C2 "SCALE 1 : 20
70
25 6 LEGGED
COLUMN " C4 "
14 T 16
SCALE: - 1 : 20
STIR
RU
PS
Y 8
@2
0 c
m c
/ c
733
77340
25
35
-----------
-----------
-----------
-----------
-----------
-----------
C76 LEGGEDT 8 mm @ 20 cm c / c20 T 1630 x 80 Foundation To G.F.Slab
C8 6 LEGGEDT 8 mm @ 20 cm c / c20 T 1625 x 90 -----------
STIR
RU
PS
16 T 16
Y 8
@2
0 c
m c
/ c
25
60
6 LEGGED COLUMN " C3 "SCALE 1 : 20
70
25 6 LEGGED
COLUMN " C5 "
16 T 16
SCALE: - 1 : 20
STIR
RU
PS
Y 8
@2
0 c
m c
/ c
20 T 1625
80
6 LEGGED
STIR
RU
PS
Y 8
@2
0 c
m c
/ c
COLUMN " C6 "SCALE: - 1 : 20
20 T 1630
80
6 LEGGED
STIR
RU
PS
Y 8
@2
0 c
m c
/ c
COLUMN " C7 "Foundation To G.F.Slab
6 LEGGEDT 8 mm @ 20 cm c / c20 T 1625 x 80 G.F.Slab To Roof Slab
20 T 1625
80
6 LEGGED
STIR
RU
PS
Y 8
@2
0 c
m c
/ c
COLUMN " C7 " G.F.Slab To Roof Slab
SCALE: - 1 : 20 SCALE: - 1 : 20
Fcu = 400 Kg/Cm2
NOTES :
Fy = 4600 Kg/Cm2
SCALE: - 1 : 2085
220
UN
DER
GR
OU
ND
WA
TER
TA
NK
TO
TA
L 8,0
00
GA
LS C
AP
AC
ITY
30
00
GA
LS F
OR
FIR
E U
SE
50
00
GA
LS F
OR
DO
MESTIC
USE
NOTE:-
INDICATING COLUMN UP TO GROUND FLOOR SLAB LVL *
N.C 165
10 10
0
90
10N.C
10
FOUNDATION LAYOUT
1:100 09
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
BOTH WAYS
T 16 @ 10 CM C/C
150
150
150 150
300
'B' EXTRA AT BOTTOMSCALE 1:50
150
150
'C' EXTRA AT BOTTOMSCALE 1:50
15
01
50
150 150
30
0
BOTH WAYS
T 16 @ 15 CM C/C
BOTH WAYS
T 16 @ 20 CM C/C
150
150
150 150
300
'A' EXTRA AT BOTTOMSCALE 1:50
Fcu = 400 Kg/Cm2
NOTES :
Fy = 4600 Kg/Cm2
1 2 3 4 6 7 8 9 10 11 125
A
C
D
F
G
H
J
I
K
E
B
10 410 85 315 50 210 120 120 260 315 75 420 10
2400
10
370
260
110
330
120
125
120
80
235
360
110
10
27
00
RAFT FOUNDATION LAYOUTSCALE - 1 : 100
155
O
L
C1C2 C2
C4C2 C2 C1
C2 C6
C6
C6
C6
80
15
C6C2
N.C
10
10 C2
C2
C2
C5
C3
C6C7*C7C6
C7C7*
C5
C3
C7C8
C6 C6 C7
N.CC5
C5C6C5 N.C
C1 C5
C2
C3 N.C
C6 C5
C5C5
C5
C5
C1*M
C2
C2 C3C2*
C2
N
534881 865
1141767 864 538
896
866
733
773
773
434
756
1026
9501598
1504 1193
1440
964
320 405
914 1979 2036
2005
187018551039
829
538
1135
184 166
462
1845
1413
1870118 1613 1724 133
1452
18101496
17691978 1486
1415
770
131618881260
472
50
150
150
AA
B A
1598
C
CC
B
B
C A
C B
A
C
B
B A
A
B
Y 16 @15 CM c/c B/W BOTTOM45 cm THICK RAFT
Y 16 @20 CM c/c B/W TOP
85
220
NOTES :
* STRUCTURE DESIGNED FOR GROUND+2 ONLY
* EXCAVATION AS PER SOIL INVESTIGATION REPORT
* PROVIDED SOLID BLOCK WORK BELOW TIEBEAM LVL-
UNDER ALL INTERNAL & EXTERNAL WALLS.BOTTOM STEEL :-
LEGEND
TOP STEEL :-
ALL COLUMN LOADS ARE ULTIMATE LOAD IN KNS.
2T16
2T16
2T16
2T16
NOTE:-
INDICATING COLUMN UP TO GROUND FLOOR SLAB LVL *
190
18
0
300
30
0
300
30
0
300
30
0
300
30
0300
30
0
280
30
0
280
30
0
300
30
0
300
30
0
300
30
0
55 cm THICK
55 cm THICK
55 cm THICK 55 cm THICK
55 cm THICK
55 cm THICK
55 cm THICK
55 cm THICK
55 cm THICK 55 cm THICK
15
0
150
15
0
150
N.C
166
N.C
184
150
UN
DER
GR
OU
ND
WA
TER
TA
NK
TO
TA
L 8,0
00
GA
LS C
AP
AC
ITY
30
00
GA
LS F
OR
FIR
E U
SE
50
00
GA
LS F
OR
DO
MESTIC
USE
20
20
20
25
25
16
0
210
AS/
SCH
FLOOR LVL
N.T.S
COL.
AS PER SCH.
(INTER LOCK LVL)
45 RAFT
10
TYPICAL DETAIL OF RAFT(TO AT LEAST 98% OF M.D.D )WELL COMPACTED SUB GRADE
AS /
SIT
E CO
NDIT
ION
25 CM THICK WELL
COMPACTED ROAD BASE ( 3 LAYERS )
NGL
FINISHED
1000 GUAGE
POLYTHENE SHEET
10 CM THICK P.C.C.
2525
260
130
25
300
30
0
55 cm THICK
TOP EXTRA(TYP) T12@15CM BOTHWAYS
2700
2900
LIFT STEEL & RAFT DETAIL
1:50 10
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
FREE FROM IMPURITIES & OTHER INJURIOUS COMPOUNDS.
13. WATER BEING USED FOR CONSTRUCTION SHALL BE DRINKING WATER
12. USE WASHED AND CRUSHED AGGREGATES FOR CONSTRUCTION
10 . USE WATER PROOF PLY FOR FORM WORK.
9. STRUCTURE IS DESIGNED FOR GROUND +2 ONLY
FACTORY AVERAGE COMPRESSIVE STRENGTH OF SOLD BLOCK SHALL BE
8. ALL CEMENT CONCRETE BLOCKS SHALL BE FROM AUTOMATIC BLOCK
7. ALL CEMENT USED SHALL BE SHARJAH/RAK. MAKE.
6. ALL RE-INFORCEMENT SHALL BE QATAR ORIGIN HAVING A MINIMUM
RESISTING PORTLAND CEMENT
5. ALL BURIED CONCRETE MIXES SHALL BE DONE USING SULFATE
4. PLAIN CEMENT CONCRETE SHALL HAVE A MINIMUM 28 DAYS CUBE
3. UNLESS OTHER SPECIFIED REINFORCED CONCRETE SHALL HAVE A MINIMUM
CONSISTENCY AND MECHANICALLY VIBRATED TO THE MAXIMUM DENSITY
2. CONCRETE SHALL BE PREMIXED/MACHINE MIXED TO THE PROPER
1. CONCRETE MIX SHALL BE AS PER C 8110 -85
STRUCTURAL GENERAL NOTES
NOTES ABOUT SOIL REPORT:-
REF- CST 2015-0015
CONSULT SOIL TESTING LAB
DATE: 18/10/2015
From reading of the boreholes log and other data, shallow foundation ( isolated
footings with tie beams and/ or strip footing & Raft ) foundations are suitable to be
used in this project.
1.
Topsoil at the existing ground surface should be removed and excavated to a depth of
2.60m below the Existing Ground Floor Level.
2.
Place three (3)Layer of selected granular backfill materials (Road Base) 25cm thick
each to each the required foundation level.The layerb shall be compacted by heavy
vibratory roller to a degree of compaction not less than 98% of the maximum dry
density as obtained by modified proctor compaction test (ASTM D 1557-98)
4.
Shallow foundation can be placed on engineered fill. (i.e., Approximately -1.85m
below the existing ground surface level.
5.
The foundation settlement related to these values of pressure is less than the
tolerable limits of 1 inch (25mm) for the isolated and 2 inch (50mm) for Raft
foundation.
Adequate cover of backfill (minimum 0.5m) shall be provided above the top of the
foundation to protect the foundations ground from erosion and seasonal weather
variation
6.
ALLOWABLE BEARING CAPACITY FOR ISOLATED/ STRIP FOOTINGS
Width Of Footing Allowable Bearing Pressure Modulus Of Sub-grade
Up to 2.00m
Up to 3.00m
Up to 4.00m
Raft
FOUNDATIONAS /SCHEDULE
Y10@20cm c/c
Y12@15cm c/c
SECTION "Z-Z"
TO
RO
OF
FIRST FL.SLAB AS/PLAN
Y12@15cm c/c
Y10@20cm c/c
AS/
SCH
FLOOR LVL
N.T.S
COL.
AS PER SCH.
(INTER LOCK LVL)
45 RAFT
10
TYPICAL DETAIL OF RAFT(TO AT LEAST 98% OF M.D.D )WELL COMPACTED SUB GRADE
AS /
SIT
E CO
NDIT
ION
25 CM THICK WELL
COMPACTED ROAD BASE
( 3 LAYERS )
NGL
FINISHED
1000 GUAGE POLYTHENE SHEET
10 CM THICK P.C.C.
2525
Fcu = 400 Kg/Cm2
NOTES :
Fy = 4600 Kg/Cm2
260
130
DETAIL OF LIFT SHEAR WALLSCALE= 1:20
Y12@15cm c/c
10-T 16 (typ)
Y12@15cm C/C
8-T 16 (typ)
10-T 16 (typ)
8-T 16 (typ)
Y10@15cm C/C
190
18
0
Y10@15cm c/c
8T 20cm c/c(typ)
stirrups
ZZ
25
Compact using heavy rollers, the soil at the bottom of excavation at level of -2060m
below the existing ground surface level,to at least 95% of its maximum dry density at
its optimum moisture content obtained from Modified Proctor Compaction Test .The
foundation depth may vary according to architectural requirement.
3.
TIE BEAM LAYOUT
1:100 11
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2SouthEXTRA BARSTRAIGHT CURTAIL STRAIGHT
2 T 16
2 T 16
2 T 16
TB2
TB3
TB1
20 x 50 2 T 16
20 x 50
20 x 40 2 T 16 -------- T 8 mm @ 20 cm c / c---------
SCHEDULE OF TIE BEAMS
TYPEBOTTOM STEEL
SIZE STIRRUPSTOP STEEL FACE
T 8 mm @ 20 cm c / c
T 8 mm @ 20 cm c / c3 T 16
2 T 16TB4 20 x 50 3 T 16 T 8 mm @ 20 cm c / c
2 T 12
2 T 12
2 T 12
--------
-------- 2 T 16
--------
2 T 12
20
SOLID BLOCK
1010
SECTION @ S-SSCALE 1 : 50
20
GATE LVL
HOLLOW BLOCKGUAGE POLYTHENE SHEET
CERAMIC TILES
COMPACTED EARTH FILLING
10CM THICK P.C.C OVER 1000
+ 30 cm LVL
30
TIE BEAM AS/SCHED.
A- 142 MESH
20 cm THICK WELL COMPACTED
ROAD BASE.
5 T 12
T 12 mm @ 20 cm c / c
10 cm THICK PCC
4 T 12
T 8 mm @ 20 cm c / c10 cm / 20 cm THICKHOLLOW BLOCK WALL
F.F.L.
(20 x 20) COPING BEAM
20 cm THICK SOLID
BLOCK WALL
N.G.L.
VARI
ED
T 12 mm @ 20 cm c / c
5 T 12
COLD BITUMEN
201000 GUAGEPOLYTHENE SHEET
STRAP FOUNDATION
1010 10
2 COATS OF
20 cm THICK WELL COMPACTEDROAD BASE.
2510 10
SCALE 1 : 20
TYP. DETAIL OF SOLID BLOCK WALL 20/10 cm
130
20
10 cm THICK PCC
AS /
DRA
WIN
G
GATE LEVEL
10 cm THICKNESS P C C WITH
BRC MESH 6mm OVER OF POLYTHENE
SHEET 1000 GAUGE.
25
2 T 16TB5 20 x 60 3 T 16 T 8 mm @ 20 cm c / c2 T 12-------- 1 T 16
2 T 16TB6 20 x 60 3 T 16 T 8 mm @ 20 cm c / c2 T 12-------- 2 T 16
---------
1 T 16
TIE BEAM LAYOUTSCALE - 1 : 100
1 2 3 4 6 7 8 9 10 11 125
A
C
D
F
G
H
J
I
K
E
B
10 410 85 315 50 210 120 120 260 315 75 420 10
2400
10
370
260
110
330
120
125
120
80
235
360
110
10
27
00
155
O
L
M
N
85
220
NOTE:-
' SB ' INDICATING 20CM SOLID BLOCK .
- INDICATING TIEBEAM IS +30 CM LEVEL
ALL TIEBEAMS ARE +150 CM LEVEL
FLOOR LEVELS WILL BE ADJUSTED BY BLOCK WALL ** *Fcu = 400 Kg/Cm2
NOTES :
Fy = 4600 Kg/Cm2
SB
SB
SB
SB
SB
SB
SBSB
SBSB
SB SB
s
s
TB3** TB3** TB3** TB3** TB3** TB3**
TB6
TB6**
TB1**
TB1
TB4
TB4
TB4
TB1 TB1
TB1**
TB1**TB1**
TB1**
TB1**
TB7TB1
TB1 TB1TB1
TB7
TB6SB
SB
TB4**
TB4**
TB4**
TB4**
TB4**
TB4
TB6**
TB6**
TB6
TB6**
TB6**
TB6**TB2**
TB2**
TB4**
TB4**
TB4**
TB4**
TB4
TB4
TB4
TB4TB6
TB6
TB7
TB6
TB2 TB2
TB6
TB6
TB3
TB1 TB1
TB1TB3
TB3
SB SB
TB5
TB5 TB5 TB5
TB2
TB6
TB4
TB2
TB4
TB4TB6TB6TB6TB6
TB3 TB3
TB3
TB3
TB2
TB2
TB2
TB6
TB6 TB6
TB6
TB6 TB3
TB4
TB3
TB3TB1
TB1
TB6
TB2
TB6
TB5 TB5
TB6
TB1
TB2
TB5
TB5
3 T 16TB7 20 x 60 3 T 16 T 8 mm @ 20 cm c / c2 T 12-------- --------
TB3
SB
SB
TB6
TB3
UN
DER
GR
OU
ND
WA
TER
TA
NK
TO
TA
L 8,0
00
GA
LS C
AP
AC
ITY
30
00
GA
LS F
OR
FIR
E U
SE
50
00
GA
LS F
OR
DO
MESTIC
USE
TB6
25
150
15
149
10
GROUND FLOOR COVERING SLAB & BEAM LAYOUT
1:100 12
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
SCALE - 1 : 20
PARAPET DETAIL @ X-X
BEAM AS/SCH.
SLAB AS/SCH.
120
100
20
35
1010
100
8 8
20
10 T 7 NO'S
T 8@ 20 cm c/c
B1B1
B2 B2B1
B1
B5
B6
B6
B7 B7 B7 B7 B7 B7
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B5
B3
B3
B1
B3
GROUND FLOOR COVERING SLAB & BEAM LAYOUTSCALE - 1 : 100
TOP & BOTTOM Y 12 @20 CM c/c B/W
25 cm THICK SLAB
G
F
G
A F
B
C
A
A
B
GFAGF
G
G G
F G
G
F
F F C
E
F
G
STST
B1
F
CB1 CB1
FC FC
Y 12 @ 15 CM c/c
L= 3.0 M
B4 B4
Y 12 @ 15 CM c/c
L= 3.0 M
100100
B1
B1
B3
Y 1
2 @
20 C
M c
/c
L=
4.0
M
4 T 16T & B
4 T 16T & B
4 T 16T & B
6575
Y 1
6 @
20 C
M c
/c
L=
3.8
M380
150
150
150 150490Y
16 @
20 C
M c
/c
L=
3.5
0 M
350
150
150500
Y 1
2 @
15 C
M c
/c
L=
3.6
M360
100
100
Y 1
6 @
20 C
M c
/c
L=
3.0
M770
100
100
Y 1
6 @
20 C
M c
/c
L=
3.0
M 300
150
Y 1
6 @
20 C
M c
/c
L=
1.7
M
170
100
150
Y 1
6 @
20 C
M c
/c
L=
3.0
M 300
150
LIFT(for future)
4 T 16T & B
Y 12 @ 15 CM c/c
L= 2.0 M200
720
50
1 2 3 4 6 7 8 9 10 11 125
A
C
D
F
G
H
J
I
K
E
B
10 410 85 315 50 210 120 120 260 315 75 420 10
240010
370
260
110
330
120
125
120
80
235
360
110
10
270
0
155
O
L
M
N
85
220
XX
XX
DETAIL OF MAIN STEEL FOR FLAT SLABN.T.S
25
T 12 mm @ 20 cm c / c
T 12 mm @ 20 cm c / c
FLOOR FINISH15
BOTTOM STEEL :-
LEGEND
TOP STEEL :-
STIRRUPS
T 8 mm @ 20 cm c / c20 x 50
SIZE
SCHEDULE OF BEAM
20 x 50
TYPE
B1
B2
FACEBOTTOM STEEL TOP STEEL
STRAIGHT
2 T 16
CURTAIL
--------
STRAIGHT
2 T 16
EXTRA BARREMARKS
2 LEGGED
2 LEGGEDT 8 mm @ 20 cm c / c2 T 162 T 16 2 T 16
T 8 mm @ 20 cm c / c20 x 60B3 3 T 163 T 16 2 LEGGED
2 T 12
2 T 12
T 8 mm @ 20 cm c / c20 x 60B4 2 T 163 T 16 2 LEGGED
T 8 mm @ 20 cm c / c20 x 50B5 2 T 163 T 16 2 LEGGED------- 2 T 12
2 T 12
2 T 12
--------
--------
-------- --------
-------- 2 T 16
T 8 mm @ 20 cm c / c20 x 50CB1 4 T 162 T 16 2 LEGGED------- 2 T 12
T 8 mm @ 20 cm c / c20 x 50B6 2 T 164 T 16 2 LEGGED------- 2 T 12
T 10 mm @ 15 cm c / c80 x 70B7 12 T 1616 T 16 4 LEGGED------- 4 T 12--------
2 T 16
2 T 16
Fcu = 400 Kg/Cm2
NOTES :
Fy = 4600 Kg/Cm2
SCHEDULE OF STAIR WAIST SLAB
LONG SPANIN cm
THICK.TYPE
SHORT SPAN
STEELREMARKS
ST 22 cm T 12 mm @ 15 cm c / cT 16 mm @ 10 cm c / c
STAIR WAIST SLABTOP & BOTTOM STEEL
--------
NOTE:-
X- INDICATING COLUMN STOPPED UP TO GROUND FLOOR SLAB LVL
Y 1
2 @
20 C
M c
/c
L=
4.0
M
400
Y 1
2 @
20 C
M c
/c
L=
4.0
M
400
100
100
100 100
H
H H
H H
340
Y 1
6 @
20 C
M c
/c
L=
4 M
70
70
H
H
XX
YY
SCALE - 1 : 20
PARAPET DETAIL @ Y-Y
BEAM AS/SCH.
SLAB AS/SCH.
120
100
20
35
1010
100
8 8
20
8 mm STIRRUPS @ 15 cm C/CTIE WITH EXTERNAL COLUMNSAT ROOF WITH PARAPET WALL.
PHERIFEVAL COLUMN @ ROOF
B4
B4
400
EE
18 T 1620
80
6 LEGGED
STIR
RU
PS
Y 8
@2
0 c
m c
/ c
COLUMN " FC "SCALE: - 1 : 20
B2
B2
B1
B1
TOWER SLAB & BEAM LAYOUTSCALE - 1 : 100
TO
P &
BO
TTO
M
Y 1
2 @
20 C
M c
/c
B/W
22
cm
TH
ICK
SLA
B
TOWER SLAB & EXTRA DETAILS
1:100 13
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
T 16 @ 15 CM C/C @ TOP
15
01
50
150150
'A' EXTRA AT TOPSCALE :- 1 : 50
BOTH WAYS
T 25 @ 10 CM C/C @ TOP
15
01
50
150150'B' EXTRA AT TOP
BOTH WAYS
SCALE :- 1 : 50
T 16 @ 10 CM C/C @ TOP
15
01
50
150150'C' EXTRA AT TOP
BOTH WAYS
SCALE :- 1 : 50
T 16 @ 20 CM C/C @ TOP
15
01
50
150150
'D' EXTRA AT TOP
ONE WAY
SCALE :- 1 : 50
T 16 @ 20 CM C/C @ TOP
15
01
50
150150
'E' EXTRA AT TOP
BOTH WAYS
SCALE :- 1 : 50
T 16 @ 15 CM C/C @ TOP
15
01
50
150150
'F' EXTRA AT TOPSCALE :- 1 : 50
BOTH WAYS
T 20 @ 10 CM C/C @ TOP
15
01
50
150150'G' EXTRA AT TOP
BOTH WAYS
SCALE :- 1 : 50
STIRRUPS
T 8 mm @ 20 cm c / c20 x 50
SIZE
SCHEDULE OF BEAM
20 x 60
TYPE
B1
B2
FACEBOTTOM STEEL TOP STEEL
STRAIGHT
2 T 16
CURTAIL
--------
STRAIGHT
2 T 16
EXTRA BARREMARKS
2 LEGGED
2 LEGGEDT 8 mm @ 20 cm c / c3 T 163 T 16 2 T 12
2 T 12--------
--------
Fcu = 400 Kg/Cm2
NOTES :
Fy = 4600 Kg/Cm2
DETAIL OF MAIN STEEL FOR FLAT SLABN.T.S
22
T 12 mm @ 20 cm c / c
T 12 mm @ 20 cm c / c
--------
T 12 @ 20 CM C/C @ TOP
15
01
50
150150
'H' EXTRA AT TOP
BOTH WAYS
SCALE :- 1 : 50
280
580
UNDER GROUND WATER TANK DETAILS
1:100 14
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
1) - WATER PROOF SHOULD BE APPLIED FOR THE WATER TANK.
NOTE:-
OF ITS OPENING DIMENSION.2) - OPENING STEEL LENGTH SHOULD BE TWICE-
( BOTH WAYS )
Y 16 @ 15 CM T/BFINISHED FLOOR LVL
10
Y 12 @ 12 CM C/C T& B
INTER LOCK LVL /
POLYTHENE SHEET
10cm THICK P.C.C
N.T.S
SECTION 'Q-Q'
HEAVY DUTY MANHOLE ( TYPICAL )
WATER TIGHT 60 cm X 60 cm
+ 1000 G POLYTHENE
2 COAT HOT BITMIN
INTERNAL SIDE OF THE TANK SHALL BE WATER PROOFED
WITH NITO PROOF AND FINISHED WITH CERAMIC TILES
15
Y 16 @ 15 CM T/B
100
20
( BOTH WAYS )
T 16 @ 15CM C/C
T 16 @ 15CM C/C
1000 GUAGE
25
FREE BOARD LVL.
CJ-0725-3K
HYDROTITE
10
20
140
25
AS / SCHEDULE
WELL COMPACTED SUB GRADE
(to at least 95% of m.d.d )
25
RAFT 45
10
25
Y 16 @ 15 CM T/B
( BOTH WAYS )( BOTH WAYS )
Y 16 @ 15 CM T/B
First Pour
Second Pour
NOTES
PLAN OF UNDER GROUND WATER TANK
SCALE 1:50 SCALE 1:50
ROOF LAYOUT OF UNDER GROUND WATER TANK
180
890
360 60 345870
214
220
51
395
320
595
60
UNDER GROUND WATER TANKTOTAL 8,000 GALS CAPACITY
3000 GALS FOR FIRE USE5000 GALS FOR DOMESTIC USE
20
180
890
360 60 345
870
214
220
51
395
320
595
60
20
( TYP. )
4T16 Tx B
25 cm THICK SLABY16@15CM c/c BOTHWAYS T&B
725830
174
191
630
25
260cm
LV
L
(-175cm lvl )
(-130cm lvl )
(+20cm lvl )
(+30cm lvl )
(-5cm lvl )
(-105cm lvl )
(-260cm lvl )
STAIR CASE DETAILS
1:100 15
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
LANDING BEAM AS / SHEDULE
17
.29
T 12 @ 15 cm c/c
T 16 @ 10 cm c/c
THK. AS PER SHEDULE
30
TIE BEAM AS PER SHEDULE
T 8 mm ( TYP )
T 8 @ 20 cm c/c1
7.2
9
30
FIRST FLOOR LVL
LANDING LVL
LANDING LVL
G.F LVL
T 8 mm ( TYP )
T 8 @ 20 cm c/c
STAIR CASE DETAIL OF FIRST FLIGHTN.T.S
STAIR CASE DETAIL OF SECOND FLIGHT(TYPICAL)N.T.S
T 16 @ 10 cm c/c
T 12 @ 15 cm c/c
22
22
TREAD - 30. 00 cmRISER - 17.29 cm
Fcu = 400 Kg/Cm2
NOTES :
Fy = 4600 Kg/Cm2
PUMP ROOM
TELE.ROOM
PROPOSED BUILDING GROUND FLOOR
R O A D
P L O TP
L
O
T
P L O
T
300 2400 300
3000 cm3
00
0 c
m
30
02
70
0
15
0
LOCATION PLANN.T.S
1096
1094
R O A D
1093
1092
1098
10991095
64
0GENERATOR ROOM
Under Ground Water TankTotal 6,000 Gals Capacity3000 Gals For Fire Use
3000 Gals For Domestic Use
2"
Pip
e
WATER M.H
60X60X80 CM
FEWA MAIN CONECTION
SETTING OUT PLAN FOR WATER SUPPLYSCALE - 1 : 100
SETTING OUT PLAN FOR WATER SUPPLY
1:100 24
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
400
ELEC.ROOM
155
200
LD1220
TOILETPANTRYD2
V
GROUND FLOOR SANITARY LAYOUT PLAN
1:100 16
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
SANITARY LEGEND
SYMBOL
EXHAUST FAN
DESCRIPTION
COOKING RANGE
SINK
WATER HEATER
W.C. ( COMMODE )
MAN HOLE
WATER CLOSET
BIDET
HAND WASH BASSOON
BATH TUB
GULLY TRAP
FLOOR TRAP
WASHING MACHINE
SHOWER TRAY
SOIL PIPE ( S.P - 4" )
WAST PIPE ( W.P - 3" )
VENT PIPE ( W.P - 3" )
H
FT
BED ROOM
BED ROOM
LIVING ROOM
TOILET
TOILET
BED ROOM
BED ROOM
LIVING ROOM
KITCHEN
TOILET TOILET
TOILETTOILET
KITCHEN
BED ROOM
LIVING ROOM
TOILETTOILET
KITCHEN
BED ROOM
LIVING ROOM
FIRE CAB.
LIFT
KITCHEN
PUMP Rm TELE.Rm
ELEC.ROOM
SHOP # 3SHOP # 2 SHOP # 4 SHOP # 5
TRANSFORMER ROOM
SHOP # 1
UP
WATCH MAN ROOM
TOILET
A/W A/W
A/W
P
A
S
S
A
G
E
(for future)
TOILETPANTRY
FT
SLOPE - 1:60
15CM UPVC PIPE
SLOPE - 1:60
15CM UPVC PIPE
SLOPE - 1:60
15CM UPVC PIPE
SLOPE - 1:60
15CM UPVC PIPE
SLOPE - 1:60
15CM UPVC PIPE
SLOPE - 1:60
15CM UPVC PIPE
SEPTIC No # 6
TANK
SW.
SLOPE - 1:60
15CM UPVC PIPE
SLOPE - 1:60
15CM UPVC PIPE
SLOPE - 1:60
15CM UPVC PIPE
FT
FT
FT
FT
FT
FT
FT FT
FT FT
FT
FT
FT
FT
GROUND FLOOR SANITARY LAYOUT PLANSCALE - 1:100
A/W
120
90
SLOPE - 1:60
15CM UPVC PIPE
SLOPE - 1:60
15CM UPVC PIPE
Pum
p R
m
MM
MM
M3
03
03
03
0
WATER METER ROOM DETAIL
WATER METER ON WALL ( GROUND FLOOR ).
( FLAT # 01 to 04 & W. MAN RM)
All water supply pipes
should be concealed in wall
GROUND FLOOR WATER SUPPLY LAYOUT PLAN
1:100 17
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
SANITARY LEGEND
SYMBOL
EXHAUST FAN
DESCRIPTION
COOKING RANGE
SINK
WATER HEATER
W.C. ( COMMODE )
MAN HOLE
WATER CLOSET
BIDET
HAND WASH BASSOON
BATH TUB
GULLY TRAP
FLOOR TRAP
WASHING MACHINE
SHOWER TRAY
SOIL PIPE ( S.P - 4" )
WAST PIPE ( W.P - 3" )
VENT PIPE ( W.P - 3" )
H
FT
BED ROOM
BED ROOM
LIVING ROOM
TOILET
TOILET
BED ROOM
BED ROOM
LIVING ROOM
KITCHEN
TOILET TOILET
TOILETTOILET
KITCHEN
BED ROOM
LIVING ROOM
TOILETTOILET
KITCHEN
BED ROOM
LIVING ROOM
FIRE CAB.
LIFT
KITCHEN
PUMP Rm TELE.Rm
ELEC.ROOM
SHOP # 3SHOP # 2 SHOP # 4 SHOP # 5
SHOP # 1
UP
WATCH MAN ROOM
TOILET
A/W A/W
A/W
P
A
S
S
A
G
E
(for future)
TOILETPANTRY
FT
FT
FT
FT
FT
FT
GROUND FLOOR WATER SUPPLY LAYOUT PLANSCALE - 1:100
M M M MM
2"
Pip
e
FEWA MAIN CONECTION
TRANSFORMER ROOM
A/W
120
90
FT FT
FT FT
FT
FT
FT
FT
FT
2400
LIFT
2850
58
0
280
(for future)
TOWER FLOOR WATER SUPPLY LAYOUT PLAN
SCALE - 1:100
All water supply pipes
should be concealed in wall
( Cap. 1500 GL x 2 = 3000 GL )
For Domestic Use Only
Fro
m U
nder
Gro
und W
ate
r Tank
ROOF Water Tank
TOWER FLOOR WATER SUPPLY LAYOUT PLAN
1:100 18
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
SANITARY LEGEND
SYMBOL
EXHAUST FAN
DESCRIPTION
COOKING RANGE
SINK
WATER HEATER
W.C. ( COMMODE )
MAN HOLE
WATER CLOSET
BIDET
HAND WASH BASSOON
BATH TUB
GULLY TRAP
FLOOR TRAP
WASHING MACHINE
SHOWER TRAY
SOIL PIPE ( S.P - 4" )
WAST PIPE ( W.P - 3" )
VENT PIPE ( W.P - 3" )
H
FT
M M M MM
A/WA/W
GROUND LVL
GROUND FLOOR
SCHEMATIC DIAGRAM
TRANSFER PUMP SET VALVE CHAMBER
INCOMING WATER SUPPLY FROM FEWA
GRP WATER TANK ( TYP )
CAPACITY 1500 IMP.GLNS
8,000 GAL. UNDER GROUND WATER TANK
FOR FIRE FIGHTING USE 3,000 GLN
FOR DOMESTIC USE 5,000 GLN
( 2 Nos )
( 2 Nos )
SERVICE M.H
KITCHENTOILET
ROOF FLOOR
OVER FLOW WATER GOING TO
UNDER GROUND WATER TANK
DOBULE BED RM FLAT # 02
MMM
TERRACE FLOOR
WATCHMAN RM
M
TOILETTOILET
SINGLE BED RM FLAT # 01
1. TWO FLOAT VALVES TO BE FITTED AT THE END OF FEEDING LINE NEAR
M.H OF UNDER GROUND WATER TANK.
2. THE OPENING OF THE UNDER GROUND WATER TANK ( M.H ) NEAR THE
PUMP ROOM DOOR, WITH SIZE NOT LESS THAN 80 x 80 cm AND COVER25 cm ABOVE F.F.L.
3. MAINTAIN A DISTANCE OF 1.5 M AT LEAST BETWEEN ( WATER SUPPLY-
LINES & TANKS ) AND ( DRAINAGE LINES & TANKS ).
4. HEIGHT OF THE FEEDER LINE INLET IN THE O/G WATER TANK NOT
MORE THAN 1.5 M FROM GROUND LEVEL.
5. SECTION PANEL ( GR.P ) OR POLYETHEYLENE ( POLYCON ) TYPE
TO BE USED FOR O/G & O.H WATER TANK.
6. INCASE GRIUND WATER TANK INSIDE PUMP ROOM AT LEAST 65 cmTO BE LEFT BETWEEN THE WALL & THE TANK FROM 3 SIDE & 1.5 MFROM PUMP SIDE.
7. WATER REQUIRED FOR FIREFIGHTING PURPOSE SHOULD BE INGROUND WATER TANK.
8. CAPACITY OF OVER HED WATER TANKS NOT TO EXCEED THECAPACITY OF GRIUND WATER TANKS.
10. SUFFICIENT CLEARENCE TO BE GIVEN IN THE PUMP ROOM FORWATER PUMP AND FIRE FIGHTING PUMPS.
11. WATER METER FOR FIRE FIGHTING PUMP TO BE FITTED ON SUCTION
LINE NEVER THE DOOR OF PUMP ROOM & CLEARENCE NOT LESS THAN60 cm TO BE LEFT.
12. SERVICE WATER METER TO BE PROVIDED ON ROOF OF BUILDING &
FEEDS PUBLIC SERVICES IN ALL FLOORS.
13. 25 cm TO BE KEPT BETWEEN WATER METER INCASE OF 1 ROW &15 cm IN CASE OF 2 ROWS ( STAGGERED )
14. HEIGHT OF WATER METER FROM F.F.L IN THE LARG OF 90-150 cm.
15. LAST TWO FLOORS ONLY TO BE CONNECTED BY THE PRESSUREPUMP ON THE ROOF.
16. PRESSURE REDUCING VALVES ( P. R. V ) TO BE PROVIDE FROMFIFTH UPPER FLOOR TO THE GROUND FLOOR.
17. MAX.8 LITER CAPACITY FLUSH TANK FOR W/C TO BE USED -
WITH TWO BUTTONS.18. AUTOMATIC FLUSH SYSTEM WITH SEPARATE SENSOR FOR EACH
URINAL UNIT.
19. SELF CLOSING TIME FLOW TAPS TO BE USED FOR ABLUTION.20. LOW FLOW TAP SHOULD BE USED.
21. IT IS NOT ALLOWED TO USE DRINKING WATER FOR PLANTATIONUSE WELL WATER OR CREATED WATER FOR PLANTATION PURPOSE.
WATER SUPPLY GENEREL NOTES :
OVER HEAD WATER TANK
CLEAN OUT
BALL VALVE
FROM GROUND PUMP
FLOAT SWITCHVENT PIPE
OVER FLOW PIPE TO BE CONNECTED
TO THE NEAREST RAIN WATER OUT LET.
PSPSPG
NRV GVFCPV
Domestic pump
Domestic water
Fire water reservecapacity : 3,000 GL
Capacity : 3000 GL
Domestic Usuage
GV FC
DIESEL FIRE PUMP
FROM FEWA
FIRE PUMP SET:-
MAIN: ELECTRIC- 100 G/M AT 7 BAR
DIESEL: 100 G/M AT 7 BAR
2" Pipe
2" Pipe
PSPSPG
NRV GVFCPVGV FC
ELECTRIC FIRE PUMP
DETAILS OF FIRE FIGHTING PUMPS
2" Pipe
WATER HEATER
GATE VALVE
NON RETURN VALVE
STOP VALVE
M C W S
C W S
MAIN COLD WATER SUPPLY
COLD WATER SUPPLY
IV
FC
ST
ISOLATING VALVE
FLEXIBLE CONNECTION
STRAINER
H W S
B C W S
HOT WATER SUPPLY
BOOSTER COLD WATER SUPPLY
F / A
T / A
F / B
T / B
H / L
PG
PS
PV
FROM ABOVE
TO ABOVE
FROM BELLOW
TO BELLOW
HIGH LEVEL
PRESSURE GAUGE
PRESSURE SWITCH
PRESSURE VESSEL
KITCHEN
TOILET
KITCHENTOILET DOBULE BED RM FLAT # 03TOILET
KITCHENTOILET SINGLE BED RM FLAT # 04TOILET
PANTRYTOILET
M
SCHEMATIC DIAGRAM
1:100 19
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
FOOTING
TYPICAL DETAIL OF NIEGHBOURING
R.C.C (1:2:4)
PLAN
PLAN
LANDING BEAM AS PER SHEDULE
20
16.3
6
LANDING BEAM AS PER SHEDULE
T12@15cm c/c
T16@10cm. c/c
20
2020
10
50
20
30
30
30
20DIA
20 20
70
FROM SLAB
8 88
88
8
20
20
20
20
L3/4L2/4
L1/5
L1/4L/4
L/5
L3/5L2/5
L3
TOP EXTRA
L1
THK. AS PER SHEDULE
L1/4
L1/5
TYPICAL DETAIL OF BEAM USING
CURTIALMENT OF BARS
AS PER SHEDULE
L/7
STIRRUPS
RINGS L1/4 L1
L1/4
L
L2
L2/5
END(2)END OF TOP STRIGHT BAR BENEDED
CURTAILD BAR
END(1)
TYPICAL DETAIL OF BEAM WITH
TOP STRIGHT
BEND UP BARS
LAP LENGHT
SLAB (STEEL IS NOT SHOWN)
6T12
30
20
20
20
202020
20
202020
20
20
20
20
20
20
50
40
20
20
10
10
1020
30
60
20
20
.20 OR 10
5 cm. thk. insitu
4020
20
41
30
20
20
20
20
BOTTOM BARS 30 cm c/c
TYPICAL PARTITION WALL DETAIL
5415
G.L
1111
IN BLOCK WORK
6T1217 22 17
(1:3:6)
10 CM THK. WALL RESTING ON R.C.C SLAB
IN BLOCK WORK10 cm. PARTITION WALL
11
TYPICAL DETAIL OF SLAB PROJECTION
50
20
2020 10
20
20
30
20 CM THK. WALL RESTING ON R.C.C SLAB
SLAB (STEEL IS NOT SHOWN)
20 cm. PARTITION WALL
30
TYPICAL STAIRCASE DETAIL
PLINTH BEAM
AS PER DETAILCOLUMN REINFORCEMENT
LAP LENGTH 40 x DIA OR OVER
COLUMN REINFORCEMENT
PLINTH BEAM
AS PER DETAIL
COLUMN SIZE AS
PER SCHEDULE
50
TYP
LONG BAR AS PER SCHEDULE AS PER DETAIL
P.C.C (1:3:6)
ELEVATION
R.C.C (1:2:4)
LONG BAR AS PER
GL
SCHEDULE OR AS / DETAIL
LONG BAR AS PER SCHEDULE
CO
LUM
N B
IND
ERS
PCC(1:3:6)
A.
PC
C(1
:3:6
)
R.C
.C (
1:2
:4)
PC
C(1
:3:6
)
R.C
.C (
1:2
:4)
.
B
COLUMN REINFORCEMENT
PLINTH BEAM
AS PER DETAIL
LAP LENGTH 40 x DIA OR OVER
L/4
L/4
SLAB TH. AS PER SHEDULE
BEAM AS PER SHEDULE
L2/4
L2/4
40 x DIA OR OVER
LAP LENGTH
L/5
L/5
COLUMN SIZE AS
PER SCHEDULE
L
L
TYPICAL DETAIL OF SLAB
LONG BAR AS PER SCHEDULE D
ELEVATION
d
10
GL
BEAM IS SPECIFIEDB
d
LONG BAR ASPER SCHEDULE
10
D
ELEVATION
COLUMN BINDERS AS PER DETAIL
GL
R.C.C (1:2:4)
PCC(1:3:6)
MIN
IMU
M D
EPTH
OF
FOU
ND
ATI
ON
AS
PER
SIT
E C
ON
DIT
ION
CO
LUM
N B
IND
ERS
B
A
AS PER DETAILSCOLUMN REINFORCEMENT
LONG BAR ASPER SCHEDULE .
PCC(1:3:6)
R.C.C (1:2:4)
.
R.C
.C (
1:2
:4)
PC
C(1
:3:6
)
A
LONG BAR AS PER SCHEDULE
R.C.C (1:2:4)
PCC(1:3:6)
R.C.C (1:2:4)
PCC(1:3:6)
COLUMN SIZE AS
PER SCHEDULE
SLAB TH. AS PER SHEDULE
END OF BOTT. STRIGHT BAR BENEDED
END OF TOP STRIGHT BAR BENEDED
END OF BOTT. STRIGHT BAR BENEDED
AND MECHANICALLY VIBRATED TO THE
RESTIING PROTLAND CEMENT.
(A) FOOTINGS :- 50 mm FOR SLIDES AND 7.0mm FOR BOTTOM.
3. MINIMUM CLEAR CONCRETE COVER TO STEEL RIENFORCEMENT ARE AS FOLLOWS
SIZE SHALL BE BRDUGHT TO THE NOTICE OF THE CONSULTANT.
SHALL BE KEPT AS PER ARCHITECTURAL DRAWING,ANY DECREPANCY AT
2. ALL STRUCTURAL DRAWING SHALL BE READ IN CONJUNCITON
1. ALL DIMENSION ARE IN CENTIMETERS UNLESS OTHER WISE
HAVE A MIN.18 DAYS.CUBE STRENGHT OF 30 N/mm2.
3. ONLESS OTHERWISE SPECIFIED RILENFORCED CONCRETE SHALL
PROPER CONSISTANCY
2. CONCRETE SHALL BE READY READY MIX/ MACHINE MIXED TO THE
DONE USING SULPHATE
1. ALL CONCRETE MIX BELOW GROUND FLOOR LEVEL SHOULD BE
SPECIFIED.
MAXIMUM DENSITY.
B. GENERAL
A. CONCRETE MIX
STRUCTURAL GENERAL NOTE
UP.
DAYS).
NOTICE OF CONSULTING ENGINEER.
4. 25 mm. EXPANSION JOINT BETWEEN COLUNS TO BE FILLET WITH 25
REMOVAL ONLY WHEN THE PROPER COUNTER WEIGHT HAVE COME
2. THE CENTERING AND SHUTTERING OF CANTILEVER IS TO BE
IS TO BE REMOVAL ONLY WHEN THE PROPER COUNTER WEIGHT HAVE
C. REMOVAL OF PROPS TO BEAMS AND ARCHES UPTO CANTILEVER
B. REMOVAL OF PROPS TO SLAB UPTO 45m. SPAN - 7 DAYS (OVER 14
A. WALLS, COLUMNS AND VERTICAL SIDES OF BEAMS 24 TO 40 HRS.
USED FORMS MAY BE STRUCK AFTER EXPIRY OF THE FOLLOWING
1. IN NORMAL CIRCUMSTANCES AND ORDINARY PORTLAND CEMENT IS
8. CONCRETE USED FOR BUILDING LAYER UNDER R.C.C. FOOTING SHALL BE ]
7. THE FOUNDATION IS DESIGNED FOR GROUND+ONLY.
6. ALL R.C.C. WORKS BELOW GROUND LEVELS SHALL BE APPLIED TWO
SHALL BE ALIGNED CONCENTRIC IN BOTTOM DIRECTIONS AND SYMETRICAL.
5. UNLESS STAYTED OTHERWISE ALL THE FOOTLINGS AND COLUMNS
20 cm. DEPTH FOR EACH AND COMPACTED USING PLATE VIBRATOR
NON ORGANIC MATEREIAL WHICH IS TO BE PLACED IN LAYERS OF
4. BACKFILLING SHALL BE DONE USING SUITABLE AND APPROVED
3. LEVELS AND SETTING OUT SHALL BE DONE PROPERLY.
2 SAFE BEARING CAPACITY IS ASSUMED 10 T /M2.
FORM WORK
COME UP.
MM THK. FLEXIBLE SHEET.
INITIAL DEFLECITON.
PERIODS.
STEEL YIELD STRENGTH FY= 4600 KG/CM2
6. Y (OR) X INDICATES TOR STEEL DEFORMED HIGH YIELD STRENGTH
IF ANY OTHER CONDITION ARE THERE. THEY ARE BROUGHT TO THE
1. EARTH STRATA TO BE CHECKED AT 1.60 BELOW NATURAL GROUND
40mm FOR BLINDING BLINDING AND FOUNDATION CONC. 20 mm.
5. NOMINAL MAXIMUM SIZE OF AGG IGATE UNLESS SPECIFIED OTHERWISE,
PLAIN BARS IN TENSION = 40D IN COMPRESSION =30D
DEFORMED BARS IN TENSION = 50D IN COMPRESSION =40D
DRAWING BUT NOT LESS THAN D= DIA OF BAR.
4. LAP LENGHT OF REINFORCEMENT BAR SHALLBE AS SHOWN ONTHE
(C) R.C.C. WALL,STAIRS AND BEAMS 25mm.
FOUNDATION
FOR SUPER STRUCTURAL CONCRETE.
(E) SLABS :- 25mm.
(D) COLUMN :- 25mm.
(B) RETAINING WALL :- 50 mm FOR EARTHSIDE 70mm FOR BOTTOM.
WITH RELEVENT ARCHITECTURAL DRAWING. ALL DIMENSIONS,LEVELS ETC.
LEVEL SOIL IS CONSIDERED IN NORMAL AND REGULAR CONDITIONS.
AND WATER TO THE SUPERVISING ENGINEERS SATISFACTION.
COATS OF BITUMEN PAINT.
100mm.THK 1:2:4
3. PROPER CHAMBER IS TO BE PROVIDED IN THE SHUTTERING TO TAKE
22
STRUCTURAL GENERAL NOTE
1:100 20
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
CEILING FAN POINT
SYMBOL DESCRIPTION
FAN REGULATOR
FLORESCENT TUBE LIGHT
13 AMP. SOCKET
BRACKET POINT
CEILING POINT
CHANDELIER
BELL PUSH BUTTON
15 AMP. SOCKET
SWITCH
ELECTRICAL & SANITARY LEGEND
SINK
GALI TRAPGT
HAND WASH BASSOON
COOKING RANGE
FLUE ( SMOKE DUCT )
TELEPHONE SOCKET
ANTENNA SOCKET
FLOOR TRAP
MH ( 60 x 60 x 80 )
W.C. ( COMMODE )
FT
BIDET
SPLIT UNIT
WATER HEATER
AC FRAME ( 80 x 60 ) cm
SUB DISTRIBUTION BOARD
MAIN DISTRIBUTION BOARD
SP
SINK
BATH TUB
EXHAUST FAN
DIA 56" OR SPECIFIED
5 )
4 )
3 )
2 )
1 )
POLISHED WHITE / COLORED NATURAL MARBLE 2 cm THICK
WITH HAIRLINE JOINTS IN APPROVED PATTERN IN FLOORING
FINISHES NOTES
FINISHES CODES
OVER LEVELED CEMENT SAND SCREED.
JOINTS IN FLOORING OVER LEVELED CEMENT SAND SCREED.
POLISHED AGGLOMERATED MARBLE 1 : 2 cm THICK HAIRLINE
SAND SCREED INCLUDING MACHINE GRINDING WAX POLISHING
APPROVED TERRAZZO TILES IN FLOORING OVER LEVELED
TO ARCHITECTS APPROVAL.
FLOOR FINISHES
3 )
2 )
1 )
WALL
CEILING FLOOR
SKIRTING
2 )
SCREWS.
3 )
4 )
SKIRTING
1 )
SAME AS ABOVE EXCEPT IN TERRAZZO TILES CAST IN SITU TERRAZZO.
STAIRCASE NOSING AS PER DETAIL.
CORNER FIXED TO RENDERED WALL USING COUNTERSUNK BRASS
NATURAL MARBLE SKIRTING PIECE 2 cm THICK TO MATCH
SAME AS ABOVE EXCEPT IN AGGLOMERATED MARBLE.
STAIRCASE STEPS PROFILE 120 cm / 15 cm HIGH FROM
SAME AS ABOVE EXCEPT IN HARDWOOD WITH ROUNDED UPPER
CONJUNCTION WITH OTHER RELEVANT DRAWING.
SUPERVISION OF / OR BY LICENSED ELECTRICAL ENGINEER.
el.. EXHAUST FAN , CEILING FAN , FANCY LIGHTS ETC.
THIS DRAWING IS TO BE USED FOR ELECTRICAL PURPOSE ONLY & SHOULD BE READ IN
ALL WORKS INSTALL MATERIALS SHALL STRICTLY BE AS PER REGULATION FOR ELECT.
INSTALLATION WORK BY THE MINISTRY & RELEVANT BRITISH STANDARD AND OF BRITISH
MAKE UNLESS OTHERWISE STATED. ALL WORKS AT SITE SHALL BE CARRIED OUT UNDER
ALL WALL MOUNTED LIGHTS SHALL BE AT A HEIGHT OF 225 cm FROM FLOOR FINISHING
LEVEL OTHERWISE INDICATED. OUTLET JUNCTION BOX, TERMINAL BOX PROVIDED
FOR FLOURECENT FITTING SHALL BE 30 cm OFF CENTER IN LATERAL DIRECTION.
A CEILING ROSE SHALL BE PROVIDED FOR PORTABLE CONNECTION TO FIXED APPARATUS
AN EARTH CONTINUITY WIRE OF APPROPRIATE SIZE TO BE RUN ALL ALONG WITH WIRING
AS PER REGULATION & TO BE BONDED EFFECTIVELY WIT EVERY MATTEL PART.
ELECTRICAL NOTES
DIVIDED EQUALLY ON THREE PHASES.
CONDUIT LAYOUT.
13 )
15 )
14 )
12 )
11 )
TO A 15 AMP. CIRCUIT.
9 )
10 )
8 )
7 )
NON SLIPPERY CERAMICS TILES IN FLOORING OVER CEMENT
SAND SCREED LAID TO FALL THE JOINTS TO BE THROUGHLY
GROUTED WITH PROPRIETARY GROUP.
CEMENT SCREED FLOORING. TILES TO BE FIXED STRICTLY
PVC TILES TO ARCHITECT SECTION IN FLOORING OVER LEVELED
ACCORDANCE WITH MANUFACTURES INSTRUCTIONS.
CEMENT SLURRY & APPROVED QUALITY SURFACE HARDENER.
LEVELED CEMENT SCREED FINISHED SMOOTH WITH NEAT
SEPARATION LAYER ON 5 cm THICK APPROVED INSULATION
PLAIN CEMENT TILES ON CEMENT SAND SCREED OR EQUIVALENT
BOARDS OVER APPROVED QUALITY WATER PROOFING.
4 )
7 )
5 )
6 )
RENDERED WALL.
3 )
4 )
1 )
2 )
SAME AS ITEM No. 9 EXCEPT AS PER APPROVED PATTERN.
SAME AS ABOVE EXCEPT TREAD TO BE cm THICK & RISER TO
FIXING DETAILS TREADS TO HAVE 2 cm WIDE COUNTER SUNK
ONE PIECE PVC TREAD & RISER OF APPROVED COLOR AND
TO ARCHITECTS APPROVAL.
CARBORUNDUM ANTI SKIP STRIP.
THICK FOR STAIRCASE / ENTRANCE STEPS AS PER APPROVED
ONE PIECE NATURAL MARBLE TREAD 3 cm THICK & RISER 2 cm
STAIRCASE FLOORING
BE cm THICK.
3 )
4 )
2 )
1 )
MANUFACTURERS INSTRUCTIONS.
TROWEL APPLIED PLASTIC COATING OVER RENDERED WALL
EXTERNAL FINISHES
ELDORADO OR EQUIVALENT ARTIFICIAL STONES / CLADDING TO
HEAVY TEXTURE COAT OVER RENDERED WALLS.
SAND LIME FACING BRICKS FIXED USING NECESSARY FASTERNING OVER
ARCHITECT SELECTION OVER RENDERED WALLS FIXED AS PER
( PROFILE DECOR ).
17 )
BY THE ENGINEER.
TO ETISALAT DB ON GROUND FLOOR.
21 )
19 )
20 )
18 )
1 )
5 )
6 )
4 )
3 )
2 )
TO RENDERED WALL USING COUNTER SUNK BRASS SCREW.
WITH UPPER CORNERS & 1 cm x 1 cm REBATE BOTTOM FIXED
SAME AS ABOVE EXCEPT IN TERRAZZO TILES 2 cm THICK 12.5
POLISHED WITH COLORED MARBLE 2 cm THICK SKIRTING 120
- 125 cm HIGH FROM FINISHED FLOOR LVL. JOINTS TO MATCH
THICK 120 - 125 cm HIGH.
SAME AS ABOVE EXCEPT IN AGGLOMERATED MARBLE 1.2 cm
CERAMIC TILES DADO UP TO DOOR / CEILING HEIGHT JOINTS
TO MATCH FLOORING JOINTS & FILLED USING PROPRIETARY
STAINED POLISHED HARDWOOD SKIRTING EX 25 cm x 125 cm
-CTURERS INSTRUCTIONS.
cm HIGH.
GROUTS.
5 )
4 )
FLOORING JOINTS.
2 )
3 )
1 )
SKIRTING DADO
BUILDING AS PER DETAIL.
MACADAM TAR PAUING 7.5 cm THICK WITH APPROVED WEARING COAT OVER
PATTERNED INTERLOCK SAND LIME BRICKS PAUING 5 cm THE SAND BLINDING
BLINDING OVER WELL COMPACTED GROUND.
50 cm WIDE CONCRETE PLINTH PROTECTION AROUND PERIMETER OF THE
PRECAST CONCRETE KERB STONES TO APPROVED DETAIL.
LOOSE GRAVEL OVER LIGHTLY COMPACTED & LEVELED GROUND.
COMPACTED & LEVELED GROUND.
OVER TYPAR / TERRAM SHEET OVER WELL COMPACT GROUND.
5 cm EXPOSED AGGREGATE CONCRETE PAUING FLAGS OVER 5 cm SAND
EXTERNAL FINISHES ( PAUINGS )
FINISHED WITH 3 COATS OF APPROVED WARNISH.
NATURAL MOUNTAIN STONES / WADI CABLE OVER RENDERED WALLS5 )
16 )
PATTERN FIXED STRCTLY IN ACCORDANCE WITH MANUFA-
TO ENTER IN THE BUILDING SUPPLIED BY POWER HOUSE.
STRUCTURAL MEMBERS AND / OR CHASED INTO WALLS.
RIGHT LEFT SIDES AS PER ROOM CONDITIONS.
RIGHT LEFT SIDES AS PER ROOM CONDITIONS.
ALL 20 Amp. OR ABOVE POWER OUTLETS TO BE PILOT LAMP INDICATORS.
PROVIDED ONE No. BELL PUSH BUTTON POINT AT MAIN GATE.
MAIN CABLE TELEPHONE etc. MUST BE LEFT OUT.
250 WATTS OF FLUORESCENT LAMP OR OTHERWISE A 15 Amp. SWITCH SHALL BE USED.
BUT IT SHALL RUN IN RIG CIRCUIT. MORE THAN 3 KW LOAD SHALL NOT BE CONNECTED
TWO SOCKETS SHALL BE CONNECTED TO ONE CIRCUIT MAX. 6 OUTLETS CAN BE USED
IN CASE OF FUTURE EXTENSION OF BUILDING CONDUCTS FOR FUTURE UPPER STORY
TWO Nos. 100 mm PVC PIPER SHALL BE PROVIDED UNDER GROUND FOR SERVICE CABLE
IN CASE OF THREE PHASE SUPPLY ALL THE OUT LETS IN ONE ROOM SHALL BE FED ONLY
ON ONE PHASE & SO ARRANGED THAT THE TOTAL LOAD OF THE STRUCTURE SHALL
WIRING CONNECTION SHOWN ON THE DRAWING ARE INDICATIVE AND DOES NOT SHOW
ALL WIRING SHALL BE CONCEALED TYPE USING PVC CONDUCTS CAST INTO SLAB /
ALL SWITCHES, DIMMERS, REGULATORS etc. SHALL BE LOCATED 150 cm ABOVE FLOOR
ALL AC POWER OUTLETS SHALL BE LOCATED BELOW AC OPENING BOTTOM AND
ALL OTHER POWER OUTLETS SHALL BE 40 cm ABOVE FINISHED FLOOR LEVEL.
ALL KITCHEN POWER OUTLETS EXCEPT COOKER SHALL BE LOCATED BELOW WALL CABINET LVL.
TV / FM OUTLETS TO BE CONNECTED TO JUNCTION BOXES ON EACH FLOOR & CONNECTED
TELEPHONE OUTLETS TO BE CONNECTED TO FLOOR JUNCTION BOX & CONNECTED BY CONDUIT
ALL SWITCHES POWER / TEL.. / TV OUTLETS SHALL BE PLASTIC / METAL CLAD FINISH.
ON A SWITCH THE LIGHTING SHALL NOT BE MORE THAN 1000 WATTS INCANDESCENT AND6 )
ALL DRAWINGS SHALL BE READ CAREFULLY START OF WORK OF ANY DESCRENCIES SHOULD BE
BE BROUGHT TO THE NOTICE OF ENGINEERS.
PLINTH LEVEL TO BE ESTABLISHED AT SITE IN CONSOLATION WITH ENGINEER.
ALL DIMENSIONS ARE IN CENTIMETERS UNLESS OTHERWISE SPECIFIED.
ALL ROOMS & PASSAGES WITH MOSAIC / CERAMIC FLOORING, STAIRCASE WITH SINGLE SLAB
TOILETS, BATHS & KITCHEN WILL HAVE CERAMICS TILES FLOORING & DADO ON THE WALL WITH
GLAZED TILES UP TO DOOR / CEILING.
UNLESS STATED OTHERWISE MORTAR FOR BLOCK WORK 20 cm SHALL BE OF CEMENT SAND
( 1 : 6 ) 10 cm THICK SHALL BE OF CEMENT ( 1 : 4 ).
PLASTERING SHOULD BE 12.5 mm CEMENT MORTAR ( 1 : 6 ) ON EXTERNAL WALL 15 mm CEMENT
ARCHITECTURAL NOTES & SPECIFICATION
7 )
4 )
MARBLE.
6 )
5 )
2 )
3 )
1 )
REQUUIREMENT.
MORTAR ( 1 : 6 ( ON INTERNAL WALLS & 9.3 mm CEMENT MORTAR IN ( 1 : 4 ) ON CEILINGS.
ALL INTERNAL WALL FINISHED WITH 3 COATS OF EMULSION PAINTS APPROVED COLORS.
ALL BATH ROOMS & TOILETS WILL HAVE COMPLETE FILLING SUCH AS MIRROR, TOWEL RAILS,
ALL EXTERNAL WALL HAVE TYROLENCE / PAINTING FINISH OF APPROVED COLORS.
SOAP HOLDERS, PAPER HOLDER LIGHT ABOVE WASH BASON. THE TYPE OF WC SHALL BE AS
ALL ELECTRICAL WIRING SHOULD BE CONCEILED CARRIED OUT AS PER DRAWING & MINISTARY
ALUMINIUM RAILING WOODEN ALUMINIUM HAND RAIL TO BE PROVIDED FOR STAIRCASE.
WIRE WESH TO BE PROVIDED BEFORE PLASTERING BETWEEN RCC & BLOCK JOINTS.
G F / FIBER GLASS WATER WILL BE PROVIDED WITH APPROVED QUALITY & MAKE.
COMPOUND WALL TO BE OF 20 cm HOLLOW / SOLID BLOCK WITH PILLARS / WITHOUT PILLARS
SOLID BLOCK SHOULD BE BELOW PLINTH.
COOKING PLATFORM SHALL BE OF 18 mm PLYWOOD SHUTTER WITH FORMICA FINISH OR RCC
COVERINGS FOR WATER TANK AND AC TO BE PROVIDED WITH WOODEN FIBER GLASS / GRC.
PLATFORM WITH MARBLE FINISH.
WINDOW AC DRAINS TO BE CONNECTED TO 12 mm DIA DRAIN PIPE CONNECTED IN WALL.
TELEPHONE & WATER METER PITS TO BE PROVIDED AS PER DRAWING.
PER OWNER'S REQUIREMENT.
WITH LIGHTS & MS GATE AS PER DESIGN.
15 )
20 )
18 )
19 )
17 )
16 )
12 )
13 )
14 )
11 )
9 )
10 )
8 )
MINI. 15 x 35 cm.
ALL DOORS TO SET IN 5 cm THICK FULJAMB WIDTH HARD WOOD FRAMES, ARCHITRAVES TO BE
ALL ALUMINIUM WORKS SHALL BE SILVER / BRONZE ANODISED MEDIUM SECTION FOR WINDOWS
ALL ALUMINIUM WINDOWS / DOORS TO BE SET IN 2.5 cm x 10 cm MIRANTI FRAME.
& HEAVY SECTION FOR DOORS.
ALL GLAZING SHALL BE CLEAR / TINTED / MIRROR COATED PLAIN / WIRED / PATERNED GLASS
AS SPECIFIED 4 mm OR 6 mm.
ALUMINIUM WORKS SHALL BE INCLUSIVE OF LOCKS , HANDLES WEATHER, STRIPS/ GASKETS
MASTIC FILLING etc. AS PER ARCHITECTS APPROVAL.
ALUMINIUM DOOR TO BE PROVIDED WITH CYLENDER LOCKS.
WOODEN DOORS TO BE PROVIDED WITH BRASS / ALUMINIUM HINGES DOOR STOOPER CONCEALED
BOLTS EYE VIEWER CHAN STAYS AS APPROPRIATE LOCKS & LEVER SETS SHALL BE SELECTED AS
PER PC SUMS SPECIFIED ELSE WHERE.
GROUND FLOOR WINDOWS TO BE PROVED WITH APPROVED DESIGN ALUMINIUM / SECURITY GRILLS.
28 )
29 )
26 )
27 )
25 )
23 )
24 )
22 )
ALL HARD WOOD SHALL BE TEAK / RED MIRANTI.21 )
6 )
5 )
4 )
PAINT.
2 )
3 )
1 )
PLAIN DECORATIVE GYPSUM CORNER MOLDING TO APPROVED PATJERN.
NECESSARY FRAMING AS PER DETAIL.
PLAIN DECORATIVE GYPSUM BOARD SUSPENDED FALSE CEILING WITH
( PROFILE DECOR ) IN ACCORDANCE MANUFACTURERS INSTRUCTIONS.
MEDIUM LIGHT FIXTURE FINISH OVER RENDER WALL CEILING EQUIPMENT
TO JUTON MAGNUM 30 / FENOTEX.
APPROVED QUALITY MINERAL FIBER SUSPENDED FALSE CEILING.
SMOOTH FINISHED CEMENT PLASTER WITH 3 COATS OF EMULSION
SMOOTH FINISHED CEMENT PLASTER WITH POLYCHROME WALL
INTERNAL FINISHES WALL CEILING
GENERAL NOTES
1:100 21
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South
1 )
SANITATION & PLUMBING
PAPER ROLL HOLDER, MIRROR UNITS ETC.
NOTES
LENGTH 400 mm
4
4 Y 12
RCC BEAM 200 x 200 mm
200
VOID 1 / 3 ROOF BLOCK
3 )
4 )
AS PER MANUFACTURERS INSTRUCTIONS.
IN MASONARY OR UNDERGROUND.
5 )
7 )
8 )
6 )
9 )
10 )
OF MUNICIPALITY.
APPROVED BY THE LOCAL AUTHORITIES.
11 )
12 )
13 )
14 )
REINFORCEMENT ONLY.
SYMBOL
SANITARY LEGEND
STAINLESS STEEL SINK
DESCRIPTION
BIDET
GALI TRAP
FLOOR TRAP
BATH TUB
FT
GT
FLUE ( SMOKE DUCT )
MH ( 60 x 60 x 80 )
W.C. ( COMMODE )
HAND WASH BASSOON
COOKING RANGE
PART ELE. OF PERFORATEDWAY FOR SOAK AWAY
Y 8 mm @ 20 cm c /c
STIRRUPS
5 Y 8
CY 12 mm @ 15 cm c / c B / W
SIZE 50 TO 100 mm.STONE FILLING APPROX
RCC BEAM
7 Y 12
200
200200
400
200
VERY
ABLE
2 Y 14 mm EXT.
OF OPENING.
IN ALL SIDES
R = AS / REQ.
2 )
OUT LET
90 Kg AIR TIGHT.
C
0.24 mm MILD STEEL STEPS
@ 300 mm c / c STAGGAFO
REFER DETAIL
CHAMBER II
15cm
100 mm o UPVC
VENTILATION PIPE/
CHAMBER I
25cm
VERI
ABLE
5.10 %
CHAMBER III
DEPTHLIQUID
10cm
43cm
23cm
13cm
15cm
IN LET
150 mm o /
INVERT LEVEL OF INCOMING PIPE
UPVC PIPE
TOP CHANNEL
STOP INTESEPTIOM
G.LEVEL
N.T.S.
CHAMBER III 1/4 OF LENGTH
CHAMBER II 1/4 OF LENGTH
CHAMBER I 1/2 OF LENGTH
TO BE KEPT AS HIGH AS POSIBLE.
30cm
30cm
SECTION AT A - A
LENGTH
C.I. COVER & FRAME WIEGHT23 RCC SLAB
15 )
WITH ALL THE NECESSARY ACCESSORIES.
PIPE SIZING SHALL BE AS FOLLOWS.
WATER CONNECTIONS
16 )
DRAINAGE CONNECTIONS
DRAINAGE UNITS SHALL BE AS FOLLOWS.
/
/
C.W.L.
S.R.
/
/
COLD WATER LINE
o 4" UPVC PIIPE
o 3" UPVC PIPE
o 6" UPVC PIPE
o 2" UPVC PIIPE
BIB COCK SHOWER
SHOWER ROSE
H.W.L. HOT WATER LINE
1.00
1.00
1.00
1.25
1.25
2.00
DIA
Y 12 mm @ 15 cm c / c
DIST. BARS
2.50
2.60
3.00
2.50
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
MAIN BARSHEIGHT
SOAK WAY
200 mm THICK SOLID BLOCK WALL.
N.T.S.
SOLID BLOCK WALL
PLAN OF SOAK AWAY
1.45
D
1.10
W
1.50
1.50
1.40
1.35
1.651.50
1.501.50
L
5.56
OF TH TANKCU. METER
CAPACITY
CU. METEROF TH TANK
5.60
CAPACITY
9.50
8.10
12.87
11.25
9.20
7.40
12.80
11.00
1
TYPE
3
2
5
4 41 TO 50
51 TO 60
31 TO 40
21 TO 30
USERSLIMIT
10 TO 20
SEPTIC TANK SIZES ( m )
SCHEDULE OF STANDARD SEPTIC TANK
5.00
5.20
4.50
4.00
3.48 12 cm
THICK.
SLAB
15 cm
15 cm
15 cm
15 cm
1.50
1.50
1.50
1.50
1.75
1.75
1.75
1.75
1.30
3.00
3.00
4.00
3.50
Y 12 cm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
4.00
4.00
4.00
4.00
Y 8 mm @ 30 cm c / c
Y 8 mm @ 30 cm c / c
Y 8 mm @ 30 cm c / c
Y 8 mm @ 30 cm c / c
Y 14 mm @ 15 cm c / c
Y 14 mm @ 15 cm c / c
Y 14 mm @ 15 cm c / c
Y 14 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
Y 12 mm @ 15 cm c / c
3.00Y 12 mm @ 15 cm c / cY 12 mm @ 15 cm c / c10cm
1.70
1.65
1.80
1.70
1.70
1.70
2.00
1.80
1.70
1.70
2.25
2.00
1.802.50
2.50 1.70
1.651.70
18.05
16.36
20.06
18.05
18.20
16.40
20 .00
18.20
29.07
23.60
38.00
34.00
29.00
23.60
38.00
33.50
8
7
10
9
12
11
14
13 151 TO 175
176 TO 200
121 TO 150
101 TO 120
91 TO 100
81 TO 90
81 TO 90
71 TO 80
14.60 14.5061 TO 706 5.20
8.00
8.50
7.60
6.76
5.90
5.90
5.90
5.50
15 cm
15 cm
15 cm
15 cm
20 cm
20 cm
20 cm
20 cm
15 cm
A
/100 mm o VENT. PIPE
20cm
1 : 1 CEMENT SAND PLASTER
20cm
TRAVEL NEERO FINISH 3
20cm20cm
MAIN BARS
AS / B & S
2 Y 12 mmDISTRIBUTION BARS
AS PER SCHEDULE
5cm 5cm
20cm
A
20cm20cm
20cm
80cm
PLANN.T.S.
B
2 Y 12 mm
70cm
LENGTH ( L )
10cm 20cm
N.T.S.
16cm
N.T.S.
REINFORCEMENT DETAIL OF TOP SLAB
VARI
ABLE
2 Y 12 mm
20cm--
SECTION AT B -B
FOMMED CHANNAL
200 mm THICK SOLID BLOCK WALL.B
PLUMBING & DRAINAGE SHALL BE CONCEALED.
ALL BATHROOMS / TOILET SETS SHALL COMPARES OF THE UNITS SHOWN ON THE DRAWINGS
AND OTHER ACCESSORIES SUCH AS TAPS / VALVES, PANEL, SPRAY, SOAP TRAY, TOILET
COPPER & C.I. PIPES SHALL BE USED FOR COLD WATER CONNECTIONS & INSULATED COPPER
SHALL BE USED FOR PIPES HOT WATER CONNECTIONS WITH APPROPRIATE JUNCTIONS ETC.
FOR WATER SUPPLY G.I. PIPES OF APPROVED QUALITY & SIZE ARE TO BE USED & SHALL BE
COATED WITH BITUMINOUS AND COVERED WITH INSULATION TAPE BEFORE EMBEDDING IN
ALL THE PIPES SHALL LAID UNDERGROUND SHALL HAVE A MINIMUM EARTH COVER 60 cm
TO BE CUSHIONED & EMBEDDED HALF ROUND IN CEMENT CONCRETE ( 1 : 5 : 10 ) 10 cm TH.
6" DIA UNDERGROUND SEWER SHALL BE PITCHED FIBER PIPE OR UPVC LAID TO SLOPE 1 : 60.
WASH BASINS SHALL BE FIXED AT A HEIGHT OF 80 cm FROM FINISHED FLOOR LEVEL.
REGULATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE TO GET SEWAGE CONNECTIONS
ALL THE SANITARY & DRAINAGE WORKS SHALL BE ACCORDING TO SEWAGE AUTHORITIES
BEFORE STARTING ANY WORK REFERENCE SHOULD BE MADE TO THE DRAINAGE SECTION
THE CAPACITY OF SEPTIC TANK INCLUDES W.C. BATHS & KITCHEN WASTE. IF SEPTIC TANK IS
TO BUILT UNDER WATER TABLE ITS WALLS SHOULD BE 15 cm CONCRETE WITH TWO
MUNICIPAL CONNECTION 55 DIA
DISTRIBUTER DOWNTAXE 33 DIA
CONNECTION TO BATH / WATER HEATER 22 DIA
CONNECTION TO OTHER INDIVIDUAL UNITS 15 DIA
DOWNTAKE SOIL PIPE 110 DIA
FROM WATER CLOSETS 110 DIA
FROM FLOOR TRAPS 55 DIA
FROM WASH BASIN & BIDET 36 DIA
FROM SINK / BATH & SHOWER 42 DIA
DOWNTAKE WASTE PIPE 82 DIA
VENT PIPE & VENT STACK 55 DIA
DISTRIBUTER FOR BATH / TOILET & KITCHEN 22 DIA
PLAIN CONCRETE. THE BASE SHOULD BE OF THE SAME THICKNESS WITH ONE BASE LAYER
COVER OF SEPTIC TANK & SOAK WAY PIT HEAVY DUTY CAST IRON COVER.
ALL OTHER MANHOLE COVER SHALL BE DOUBLE SEAL / MEDIUM DUTY CAST IRON COVER.
APPROVED MAKE G.R.C. WATER TANKS SHALL BE PROVIDED AS SPECIFIED ON THE TERRACE
SEPTIC TANK & SOAK PIT AS / DETAILS SHALL BE BUILT IN SOLID / REINFORCED BLOCK.
LAYERS OF REINFORCEMENT OF 12mm Y BARS @ 15 cm c / c ( B / W ) IN EACH LAYER OF 230 mmW
IDTH
(W)
( CHRONIUM TYPE )2.05.00Y 8 mm @ 30 cm c / cY 14 mm @ 15 cm c / c2.03.095.0095.0016 500 16.0 20 cm
4.00Y 8 mm @ 30 cm c / cY 14 mm @ 15 cm c / c2.002.5050.0050.0015 201 TO 250 10.0 20 cm 1.75
SANITARY NOTES
1:100 22
MUNICIPALITY ENGINEER APPROVAL
CONSULTANT SIGNATURE AND STAMP
REVISIONS
OWNER:
PLOT NO.
PROJECT DESCRIPTION :
DRAWING TITILE :
ARCH. ENG.
SECTOR DISTRICT
Sami Abdel
STRUC. ENG. M.E.P. ENG.
Mohd.Yasith
DRAWN BY :
P.A.Rasooludheen
B-168
24/02/2016
JOB. NO. SCALE SHEET NO.
Mr. MARWAN RASHID SHAQAR ALAMI&ABDALLA JABBAR MAHMOUD SHAQALAIH
1096
PROPOSED BUILDING GROUND FLOOR
Al-Rawdha 2South