citsens bio technical data sheet - c-cit sensors ag...

6
Technical Data Sheet CITSens Bio / MeMo Content CITSens Bio........................................................................................................................................ 2 CITSens MeMo................................................................................................................................... 3 Sensortypes..........................................................................................................................................4 PG 13.5 Sensor................................................................................................................................ 4 Polymer Coated Sensor....................................................................................................................5 Cap Sensor....................................................................................................................................... 6 Page 1/6 C-CIT Sensors AG TechSheetBio_V1

Upload: vubao

Post on 10-Mar-2018

221 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: CITSens Bio Technical Data Sheet - C-CIT Sensors AG ...c-cit.ch/wp-content/uploads/2017/07/TechSheet_CITSensBio.pdfTechnical Data Sheet CITSens Bio / MeMo Content CITSens Bio ... CITSens

Technical Data Sheet CITSens Bio / MeMo

Content CITSens Bio........................................................................................................................................2 CITSens MeMo...................................................................................................................................3 Sensortypes..........................................................................................................................................4

PG 13.5 Sensor................................................................................................................................4Polymer Coated Sensor....................................................................................................................5Cap Sensor.......................................................................................................................................6

Page 1/6 C-CIT Sensors AG TechSheetBio_V1

Page 2: CITSens Bio Technical Data Sheet - C-CIT Sensors AG ...c-cit.ch/wp-content/uploads/2017/07/TechSheet_CITSensBio.pdfTechnical Data Sheet CITSens Bio / MeMo Content CITSens Bio ... CITSens

CITSens Bio

Available Sensors

Screen Printed Electrode (SPE) with Immobilized Enzyme

Delivery Gamma irradiated (25 kGy), double packed

Dimension (SPE) Length: 230 mm or 330 mmTip Diameter: 8 mmThickness: 0.15 mm

Analytes GlucoseMeasuring range 0 - 30 mmol/L 0 - 5.4 g/LPrecision +/- 0.1 mmol/LResolution 0.1 mmol/L

LactateMeasuring range 0 - 15 mmol/L 0 – 1.35 g/LPrecision +/- 0.1 mmol/LResolution 0.1 mmol/L

Glutamate On request

Page 2/6 C-CIT Sensors AG TechSheetBio_V1

Page 3: CITSens Bio Technical Data Sheet - C-CIT Sensors AG ...c-cit.ch/wp-content/uploads/2017/07/TechSheet_CITSensBio.pdfTechnical Data Sheet CITSens Bio / MeMo Content CITSens Bio ... CITSens

CITSens MeMo

Available Sensors

Screen Printed Electrode (SPE)

Delivery Gamma irradiated (25 kGy), double packed

Dimension (SPE) Length: 230 mm or 330 mmTip Diameter: 8 mmThickness: 0.15 mm

Analytes Glucose / Lactate combined

GlucoseMeasuring range 0 - 30 mmol/L 0 - 5.4 g/LPrecision +/- 0.1 mmol/LResolution 0.1 mmol/L

LactateMeasuring range 0 - 15 mmol/L 0 – 1.35 g/LPrecision +/- 0.1 mmol/LResolution 0.1 mmol/L

Glucose / Glutamate combined

GlucoseMeasuring range 0 - 30 mmol/L 0 - 5.4 g/LPrecision +/- 0.1 mmol/LResolution 0.1 mmol/L

Glutamate On request

pH

pHMeasuring range 4 – 9 pHPrecision +/- 0.1 pHResolution 0.05 pH

Page 3/6 C-CIT Sensors AG TechSheetBio_V1

Available Winter 2

017 / 2018

Page 4: CITSens Bio Technical Data Sheet - C-CIT Sensors AG ...c-cit.ch/wp-content/uploads/2017/07/TechSheet_CITSensBio.pdfTechnical Data Sheet CITSens Bio / MeMo Content CITSens Bio ... CITSens

Sensortypes

PG 13.5 Sensor for SUB

The PG 13.5 Sensor is the best choice for any stirred bioreactors.

Through the shape based on a standard pH-probe the PG 13.5 Sensor is easily integradeable to any stirred bioreactor via lid or side port.

Using PEEK as main in process material the PG 13.5 sensor provides a high biosafety grade to not affect your culture's behaviour.

Sensor specifications:

Length: 40 – 300 mm Material: PEEK (USP Class VI)

In Process Time:Glucose: 2 – 3 WeeksLactate: 2 WeeksGlutamate: On request

Product Number Description Pcs / Unit Delivery time

3002-511.1 CITSens Bio Glucose Sensor, PG 13.5, short (-160mm) 12 3 Weeks

3002-511.2 CITSens Bio Glucose Sensor, PG 13.5, long (-300mm) 6 3 Weeks

3002-512.1 CITSens Bio Lactate Sensor, PG 13.5, short (-160mm) 12 3 Weeks

3002-512.2 CITSens Bio Lactate Sensor, PG 13.5, long (-300mm) 6 3 Weeks

3002-521.1 CITSens MeMo Glu / Lac Combi Sensor, PG 13.5, short (-160mm) 12 3 Weeks

3002-521.1 CITSens MeMo Glu / Lac Combi Sensor, PG 13.5, long (-300mm) 6 3 Weeks

+41 79 935 74 [email protected]

Page 4/6 C-CIT Sensors AG TechSheetBio_V1

Page 5: CITSens Bio Technical Data Sheet - C-CIT Sensors AG ...c-cit.ch/wp-content/uploads/2017/07/TechSheet_CITSensBio.pdfTechnical Data Sheet CITSens Bio / MeMo Content CITSens Bio ... CITSens

Polymer Coated Sensor

The Polymere Coated Sensor is the best choice for any static cultivation.

Using a polymere coating instead of PEEK materials makes the sensor capable to measure in small voluminas in almost every kind of reactor.

Through the elasticity of the screen printed electrode in combination with the polymer coating makes the sensor toour first choice when developing a customized solution.

Sensor specifications:

Length: 40 – 300 mm Material: Polymer (USP Class VI)

In Process Time:Glucose: 2 WeeksLactate: 2 WeeksGlutamate: On request

Product Number Description Pcs / Unit Delivery time

3002-511.1 CITSens Bio Glucose Sensor, PG 13.5, short (-160mm) 24 3 Weeks

3002-511.2 CITSens Bio Glucose Sensor, PG 13.5, long (-300mm) 24 3 Weeks

3002-512.1 CITSens Bio Lactate Sensor, PG 13.5, short (-160mm) 24 3 Weeks

3002-512.2 CITSens Bio Lactate Sensor, PG 13.5, long (-300mm) 24 3 Weeks

3002-521.1 CITSens MeMo Glu / Lac Combi Sensor, PG 13.5, short (-160mm) 24 3 Weeks

3002-521.1 CITSens MeMo Glu / Lac Combi Sensor, PG 13.5, long (-300mm) 24 3 Weeks

+41 79 935 74 [email protected]

Page 5/6 C-CIT Sensors AG TechSheetBio_V1

Page 6: CITSens Bio Technical Data Sheet - C-CIT Sensors AG ...c-cit.ch/wp-content/uploads/2017/07/TechSheet_CITSensBio.pdfTechnical Data Sheet CITSens Bio / MeMo Content CITSens Bio ... CITSens

Cap Sensor

The Cap Sensor is the best choice for long therm monitoring in agitated environments where the PG 13.5 Sensor is not suitable.

Using PEEK as main in process material the Cap Sensor provides a high biosafety grade to not affect your culture's behaviour.

Sensor specifications:

Length: 40 – 300 mm Material: Polymer (USP Class VI)

In Process Time:Glucose: 2-3 WeeksLactate: 2 WeeksGlutamate: On request

Product Number Description Pcs / Unit Delivery time

3002-501.1 CITSens Bio Glucose Sensor, Cap Sensor, short (-160mm) 24 3 Weeks

3002-501.2 CITSens Bio Glucose Sensor, Cap Sensor, long (-300mm) 24 3 Weeks

3002-502.1 CITSens Bio Lactate Sensor, Cap Sensor, short (-160mm) 24 3 Weeks

3002-502.2 CITSens Bio Lactate Sensor, Cap Sensor, long (-300mm) 24 3 Weeks

3002-521.1 CITSens MeMo Glu / Lac Combi Sensor, Cap Sensor, short (-160mm) 24 3 Weeks

3002-521.1 CITSens MeMo Glu / Lac Combi Sensor, Cap Sensor, long (-300mm) 24 3 Weeks

+41 79 935 74 [email protected]

Page 6/6 C-CIT Sensors AG TechSheetBio_V1