cisco telepresence system tx1310 65 room recommendations · cisco telepresence system tx1310 65...
TRANSCRIPT
Cisco TelePresence System TX1310 65 Assembly, OL-26384-01
C H A P T E R 1
Cisco TelePresence System TX1310 65 Room RecommendationsRevised: February 17, 2014, OL-26384-01
The Cisco TelePresence System TX1310 65 (TX1310 65) is designed to be used in a multipurpose room (for example, a conference room). However, to ensure that you have the best conferencing experience, Cisco recommends that you optimize your room by using the guidelines and recommendations in this chapter.
This chapter includes the following sections:
• General Room Requirements and Recommendations, page 1-1.
• Supported Table Types and Minimum Room Dimensions, page 1-2
• Recommended Table Height, page 1-10
• Recommended Table Finishes, page 1-10
• Room Color Recommendations, page 1-11
• Lighting Recommendations, page 1-11
• Acoustic Recommendations, page 1-12
• Power Requirements, page 1-12
• HVAC Considerations, page 1-13
General Room Requirements and RecommendationsThe following are required elements for a TX1310 65 room:
• You must use an enclosed space.
• You must have a room with the minimum dimensions that are specified in the “Supported Table Types and Minimum Room Dimensions” section on page 1-2.
• The room must meet minimum heating, ventilation and air conditioning (HVAC) requirements that are provided in the “HVAC Considerations” section on page 1-13.
• The room must be supplied with electrical power as specified in the “Power Requirements” section on page 1-12.
• The power and Ethernet outlets must not be positioned directly behind the TX1310 65 unit.
1-1First-Time Setup, and Field Replaceable Unit Guide
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsSupported Table Types and Minimum Room Dimensions
• If you install two TX1310 65 systems in rooms that share a wall, you must not mount the systems on the same wall; mount the two TX1310 65 systems on separate walls.
• The walls in the room must meet the structural guidelines as specified in the “Important Warnings and Cautions” section on page 2-1 in Chapter 2, “Assembling and Mounting a Cisco TelePresence System TX1310 65.”
The following recommendations or guidelines ensures that you have the best possible conferencing experience:
• A white room is acceptable but not recommended for the best experience. Neutral colors work best for the floors and walls.
You can use color, décor, and signage in the room to communicate your brand and corporate identity.
Cisco recommends that you do not use colors with high contrast.
For more color information, see the “Room Color Recommendations” section on page 1-11.
• Normal office lighting is usually sufficient for a good conferencing experience. However, Cisco recommends that you perform the following actions for the best experience:
– Use indirect florescent lighting and avoid any direct lighting.
– If your room has windows, install shades to reduce glare, especially for any windows that are directly behind the participants.
For more information about lighting, see the “Lighting Recommendations” section on page 1-11.
• The TX1310 65 was designed to well in an office with normal sound levels. Large rooms, or rooms with high ceilings, can cause echo and reverberation issues. For more information about acoustics, see the “Acoustic Recommendations” section on page 1-12.
Supported Table Types and Minimum Room DimensionsThe minimum required room size is 18 x 13 feet (5.5 meters x 4 meters). The table configurations shown in Figure 1-1 and Figure 1-3 require a minimum room size of 23 x 13 feet (7 meters x 4 meters).
Figure 1-1 through Figure 1-8 show the types of tables that the TX1310 65 supports and the minimum room size for each type of table. To see the recommended table finishes, see the “Recommended Table Finishes” section on page 1-10.
All rooms must have a minimum room height of 8 feet (2.44 meters).
Cisco recommends that you use a table where at least four people sit in a straight line facing the camera. Figure 1-1 through Figure 1-7 illustrate tables that provide the best conferencing experience.
Some of these figures show the microphone placement for more than three microphones. These additional microphones are used for audio conferences only. For information about configuring these additional microphones, see the “Configuring Additional Microphones for Audio-Only Conferences” section on page 3-39.
1-2Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsSupported Table Types and Minimum Room Dimensions
Figure 1-1 TX1310 65 with Long Rectangular Table
Table and room dimensions for this configuration are as follows:
• Minimum room size is 23 x 13 feet (7 meters x 4 meters)
• This table is a maximum of 16 feet, 4 inches (5 meters) wide
• Allows all participants to sit in a straight line facing the camera, with a recommended distance between participants of 30 inches (76 centimeters)
• Minimum distance between the TX1310 65 screen and the near edge of the table is 44 inches (112 cm)
• Maximum distance between the TX1310 65 screen and the far edge of the table is 120 inches (305 cm)
• For the minimum distance between the rear edge of the table and the system, see the “Positioning the Table and Starting the Calibration Procedure” section on page 3-10
Figure 1-2 shows the table with three additional microphones that can be used with an audio-only conference.
Note For some custom installation configurations that are not shown in these figures, you can configure the additional microphones to be used during a video conference, as well as an audio conference. For more information, see the “Configuring Additional Microphones for Audio-Only Conferences” section on page 3-39.
96”(244 cm)Minimum
44”(112 cm)Minimum
3433
82
1 2 3 4 5 6
180”(472 cm)Minimum
18 inches(46 cm)
18 inches(46 cm)
18 inches(46 cm)
30”(76.2 cm)
1-3Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsSupported Table Types and Minimum Room Dimensions
Figure 1-2 TX1310 65 with Long Rectangular Table and Three Extra Microphones for Audio-Only Conferencing
96”(244 cm)Minimum
44”(112 cm)Minimum
3433
78
1 2 3 4 5 6
12 11 10 9 8 7
180”(472 cm)Minimum
18 inches(46 cm)
18 inches(46 cm)
18 inches(46 cm)
30”(76.2 cm)
1-4Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsSupported Table Types and Minimum Room Dimensions
Figure 1-3 TX1310 65 with Long Racetrack Table
Table and room dimensions for this configuration are as follows:
• Minimum room size is 23 x 13 feet (7 meters x 4 meters)
• This table is a maximum of 16 feet, 4 inches (5 meters) wide
• Allows all participants to sit in a straight line facing the camera, with a recommended distance between participants of 30 inches (76 centimeters)
• Minimum distance between the TX1310 65 screen and the near edge of the table is 44 inches (112 cm)
• Maximum distance between the TX1310 65 screen and the far edge of the table is 120 inches (305 cm)
• For the minimum distance between the rear edge of the table and the system, see the “Positioning the Table and Starting the Calibration Procedure” section on page 3-10
Figure 1-2 shows the table with three additional microphones that can be used with an audio-only conference.
Note For some custom installation configurations that are not shown in these figures, you can configure the additional microphones to be used during a video conference, as well as an audio conference. For more information, see the “Configuring Additional Microphones for Audio-Only Conferences” section on page 3-39.
1
2 3 4 5
6
96”(37.8 cm)Minimum
44”(17.3 cm)Minimum
3433
80
18 inches(46 cm)
18 inches(46 cm)
18 inches(46 cm)
30”(76.2 cm)
1-5Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsSupported Table Types and Minimum Room Dimensions
Figure 1-4 TX1310 65 with Long Racetrack Table and Three Extra Microphones for Audio-Only Conferencing
1
2 3 4 5
6
12
11 10 9 8
796”
(37.8 cm)Minimum
44”(17.3 cm)Minimum
3433
76
18 inches(46 cm)
18 inches(46 cm)
18 inches(46 cm)
18 inches(46 cm)
30”(76.2 cm)
18 inches(46 cm)
1-6Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsSupported Table Types and Minimum Room Dimensions
Figure 1-5 TX1310 65 with Short Rectangular Table
Table and room dimensions for this configuration are as follows:
• Minimum room size is 18 x 13 feet (5.5 meters x 4 meters)
• This table is at least 6 feet (1.8 meters) wide
• Allows four participants to sit in a straight line facing the camera, and two participants to sit at the corner (one on each side), with a recommended distance between participants of 30 inches (76 centimeters)
• Minimum distance between the TX1310 65 screen and the near edge of the table is 44 inches (112 cm)
• Maximum distance between the TX1310 65 screen and the far edge of the table is 120 inches (305 cm)
• For the minimum distance between the rear edge of the table and the system, see the “Positioning the Table and Starting the Calibration Procedure” section on page 3-10
102”(259 cm)Minimum
44”(112 cm)Minimum
3433
81
1
2 3 4 5
6
30”(176 cm)
60”(153 cm)
120”(305 cm)
18 inches(46 cm)
18 inches(46 cm)
1-7Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsSupported Table Types and Minimum Room Dimensions
Figure 1-6 shows the table with two additional microphones that can be used with an audio-only conference.
Figure 1-6 TX1310 65 with Short Rectangular Table and Three Extra Microphones for Audio-Only Conferencing
102”(259 cm)Minimum
44”(112 cm)Minimum
3433
77
1
2 3 4 5
6
12
11 10 9 8
7
30”(176 cm)
60”(153 cm)
120”(305 cm)
18 inches(46 cm)
18 inches(46 cm)
1-8Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsSupported Table Types and Minimum Room Dimensions
Figure 1-7 TX1310 65 with Short Racetrack Table
Table and room dimensions for this configuration are as follows:
• Minimum room size is 18 x 13 feet (5.5 meters x 4 meters)
• This table is at least 6 feet (1.8 meters) wide
• Allows four participants to sit in a straight line facing the camera, and two participants to sit at the corner (one on each side), with a recommended distance between participants of 30 inches (76 centimeters)
• Minimum distance between the TX1310 65 screen and the near edge of the table is 44 inches (112 cm)
• Maximum distance between the TX1310 65 screen and the far edge of the table is 120 inches (305 cm)
• For the minimum distance between the rear edge of the table and the system, see the “Positioning the Table and Starting the Calibration Procedure” section on page 3-10
1
2
3 4 5
5
6
96”(244 cm)Minimum
44”(112 cm)Minimum
52”(132 cm)
3433
83
96”(234 cm)
18 inches(46 cm)
18 inches(46 cm)
30”(76.2 cm)
1-9Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsRecommended Table Height
Figure 1-6 shows the table with two additional microphones that can be used with an audio-only conference.
Figure 1-8 TX1310 65 with Short Racetrack Table and Two Extra Microphones for Audio-Only Conferencing
Recommended Table Height For all table types, the table must be 28 to 32 inches (71 to 82cm) high. 30 inches (76 cm) is the optimal table height.
Recommended Table FinishesCisco recommends that the table in your TX1310 65 room have the following characteristics:
• The table tops should have a low-gloss finish (non-reflective surface)
• If you use wood a table, the wood should be a neutral, light color
• If you use a laminate or plastic table, the table top should be a neutral, light color (for example, off-white or light gray)
Cisco does not recommend using the following types of table tops:
• A table that uses a very dark or heavily saturated color (for example, wood that is reddish in color, or uses a dark wood stain)
• A table with a glass top
1
2
3 4 5
9 8
5
6
710
96”(244 cm)Minimum
44”(112 cm)Minimum
52”(132 cm)
3433
79
96”(234 cm)
18 inches(46 cm)
18 inches(46 cm)
18 inches(46 cm)
18 inches(46 cm)
30”(76.2 cm)
1-10Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsRoom Color Recommendations
• Any table top that has a reflective surface
Figure 1-9 shows examples of unacceptable table colors.
Figure 1-9 Unacceptable Table Color Examples
Room Color RecommendationsFor information about room color recommendations, refer to the Cisco TelePresence Wall Color Reference Guide.
Lighting RecommendationsThe cameras that are used in the TX1310 65 are designed to work well using normal office lighting. However, Cisco recommends that you use well dispersed, ambient light throughout the room.
The ideal lighting environment is to use indirect fluorescent lighting that uses bulbs with a rating of 4,100 Kelvins (4100k). You can supply the lighting either through recessed fixtures or pendant fixtures. Pendant lighting is best if your room is more than 9 feet (2.7 meters) high. Cisco does not recommend direct lighting.
For best results, one set of lighting should be in front of conference participants, and one set should be behind the participants.
The lighting in the room should be well controlled. You should block natural sunlight or other light that could enter through glass or thin blinds.
Cisco strongly recommends that your fluorescent lighting use electronic ballasts.
It is important to consider the direction of the lighting in your room. For conferencing purposes, lighting can come from three directions:
• Key Light—This is the primary source of lighting and typically the strongest source of lighting. Key light is built-in to the TX1310 65 light reflector.
• Fill light—This light is created primarily from the overhead lights in the room, and secondarily from the TX1310 65 light reflector. Fill light can reduce or eliminate shadowing on the conference participants that is created by the key light.
• Back light—This optional light is projected behind the conference participants. Back light is generally indirect and creates separation between the participants and the room background.
1-11Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsAcoustic Recommendations
If measuring light in the room, the light range should be between 250 and 800 lux.
For specific lux measurement specifications, see Table 1-1.
Acoustic RecommendationsThe TX1310 65 microphones and speakers are designed to be used in rooms that have typical office noise levels.
Rooms with excessive noise (greater than 55 decibels (dBA) might not provide the best conference experience.
Large rooms, high ceilings, or rooms that have a large amount of glass may experience reverberation. If possible, reduce reverberation to a level that is below 700 milliseconds across the voice spectrum (between 300 and 3000 Hertz).
Power RequirementsThe Cisco TelePresence System TX1310 65 requires one 20amp circuit @100V 120V (US electrical code requires maximum 16amp on a 20amp circuit) or one 10amp circuit @ 240V. Two receptacles must be provided for these circuits. The receptacles should be located on the wall near the intended location of the endpoint but not directly behind the endpoint.
Note Peripherals such as document cameras or alternate displays will require additional circuits and receptacles. Placement will depend on the type and location of the peripheral device.
Table 1-1 Lighting Measurement Recommendations
IlluminationTarget Measurement in Lux (= lm/m2) Tolerance Notes
Overall illumination 300-400 lux 50 lux
All lighting should be evenly dispersed. There should not be areas of 250 and 450 lux in the same room.
Measured vertically with the light sensor pointed at wall or intended camera location (not pointed at the ceiling).
Shoulder light/Direct down light
600-700 lux Generally, shoulder lighting should not be more the 400 lux greater than the overall illumination of the room, and should never exceed 800 lux
Measured horizontally at table height, with the light sensor pointed at the ceiling
1-12Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsHVAC Considerations
HVAC ConsiderationsPlanning the cooling for a TX1310 65 TelePresence room is important to insure the room remains comfortable for participants and the equipment is kept safe. As outlined in the overview section of this document, HVAC considerations should be given from the initial phase of choosing a room. The detail in the table below outlines the specific BTU output of a TX1310 65 when deployed as recommend and under typical operating conditions. Typical assumes normal usage conditions such that the system is not subject to 100 percent utilization rates and deployment following Cisco recommendations. i.e. room located on interior, proper air circulation, walls painted with neutral colors, temperature expected 72-76 degrees F. Within these guidelines and typical usage, diversity of 25 percent can be equated which lowers cooling requirements and increases overall efficiency. HVAC considerations should be given from the initial phase of choosing a room. Installing new cooling (or heating) systems can be time-consuming.
Note Conditions not consistent with these recommendations or typical usage may require additional cooling. Consult with an HVAC engineer to define building envelope and unique requirements. Additional equipment such as data displays, document cameras, etc. will require additional cooling.
Table 1-2 TX1310 65 Power Consumption
Component Maximum Typical Idle
W Amperage @120V
W Amperage @120V
W Amperage @120V
65” Plasma Display 580.8 4.84 544.8 4.54 55.2 0.46
Lights 243.6 2.03 242.4 2.02 0 0
Codec w/CTT 12 and LCU
80.4 0.67 76.8 0.64 74.4 0.62
Audio/Video Extension Unit
26.4 0.22 24.0 0.2 24.0 0.2
POWER TOTAL for TX1310 65
931.2 W7.76 amps @ 120V
888 W7.4 amps @ 120V
153.6 W1.28 amps @ 120V
Table 1-3 TX1310 65 BTU Output with 25% diversity
SourceTypical KW Typical Usage
BTUs/hr
System Power 0.75 1930
System Lighting 0.24 602
4 Participants (Avg) 0.39 998
3 Laptops (Avg) 0.17 422
Ceiling Lights for 234 sq ft room (1.4w/sqft)
0.33 837
Total Typical Heat Dissipation
4,500 BTU/Hr
1-13Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsHVAC Considerations
Figure 1-10 HVAC Diffuser Locations
Figure 1-11 NC 30 Rated Diffuser
1-14Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsHVAC Considerations
1-15Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01
Chapter 1 Cisco TelePresence System TX1310 65 Room RecommendationsHVAC Considerations
1-16Cisco TelePresence System TX1310 65 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-26384-01