202
Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 526-4100 Cisco MDS 9000 Family Fabric Manager User Guide Cisco MDS SAN-OS Release 1.0(2) March 2003 Customer Order Number: DOC-7814895= Text Part Number: 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Upload: others

Post on 27-Dec-2019

25 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Cisco MDS 9000 Family Fabric Manager User GuideCisco MDS SAN-OS Release 1.0(2)March 2003

Corporate HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAhttp://www.cisco.comTel: 408 526-4000

800 553-NETS (6387)Fax: 408 526-4100

Customer Order Number: DOC-7814895=Text Part Number: 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 2: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.

THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.

The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.

NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.

IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

CCIP, the Cisco Arrow logo, the Cisco Powered Network mark, the Cisco Systems Verified logo, Cisco Unity, Follow Me Browsing, FormShare, iQ Breakthrough, iQ Expertise, iQ FastTrack, the iQ Logo, iQ Net Readiness Scorecard, Networking Academy, ScriptShare, SMARTnet, TransPath, and Voice LAN are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, Discover All That’s Possible, The Fastest Way to Increase Your Internet Quotient, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, the Cisco IOS logo, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherSwitch, Fast Step, GigaStack, Internet Quotient, IOS, IP/TV, LightStream, MGX, MICA, the Networkers logo, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, RateMUX, Registrar, SlideCast, StrataView Plus, Stratm, SwitchProbe, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries.

All other trademarks mentioned in this document or Web site are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0208R)

Cisco MDS 9000 Family Fabric Manager User GuideCopyright © 2002, 2003, Cisco Systems, Inc.All rights reserved.

Page 3: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C O N T E N T S

Preface ix

Audience ix

Organization ix

Conventions x

Related Documentation x

Obtaining Documentation xi

World Wide Web xi

Documentation CD-ROM xi

Ordering Documentation xi

Documentation Feedback xi

Obtaining Technical Assistance xii

Cisco.com xii

Technical Assistance Center xii

Cisco TAC Web Site xiii

Cisco TAC Escalation Center xiii

Getting Started with Cisco Fabric Manager 1-1

Managing Cisco MDS 9000 Family Switches 1-1

Cisco MDS 9000 Fabric Manager 1-1

Storage Management Solutions Architecture 1-2

Managing Cisco MDS 9000 Switches 1-3

Establishing Management Connectivity 1-4

In-Band Management and Out-of-Band Management 1-4

Using the Local Console Port and the CLI 1-5

Performing Fabric Management 1-6

Discovering and Viewing the Network Fabric 1-6

Controlling Administrator Access with Users and Roles 1-7

Performing Device Management 1-8

Accessing Cisco Fabric Manager 1-9

Connecting to a Supervisor Module 1-10

Launching Views 1-11

Troubleshooting Installation and Access 1-12

Using Cisco Fabric Manager and Device Manager 2-1

Summary of Fabric and Device Management Tasks 2-1

iiiCisco MDS 9000 Family Fabric Manager User Guide

Page 4: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Contents

Using Fabric Manager 2-2

Fabric Mangaer Main Window 2-2

Menu Bar, Toolbars, and Message Bar 2-4

VSAN/Switch Pane 2-4

Information Pane 2-5

Map Pane 2-6

Locating Other Switches 2-6

Modifying Device Grouping 2-7

Troubleshooting Switch Configuration 2-9

Analyzing Switch Device Health 2-9

Analyzing End-to-End Connectivity 2-10

Analyzing Switch Fabric Configuration 2-11

Analyzing the Results of Merging Zones 2-12

Using Other Troubleshooting Tools 2-13

Setting Preferences 2-14

Viewing Reports in Fabric Manager 2-16

ISL Statistics 2-16

ISLs 2-17

Switches 2-17

Hosts 2-18

Storage 2-18

LUNs 2-19

Using Device Manager 2-19

Overview of Device Manager 2-20

Launching Device Manager from Fabric Manager 2-20

Comparing Device Manager to Fabric Manager 2-21

Managing Ports 2-24

Setting Preferences 2-24

Using Summary View 2-26

Managing Zones and Zone Sets 3-1

Creating Zones and Zone Sets 3-1

Adding Zones to a Zone Set 3-4

Cloning Zones and Zone Sets 3-4

Assigning Zone Members 3-5

Activating or Enforcing Zone Sets 3-6

Managing Zones 3-6

Searching the Zone Database 3-6

Displaying Port Membership Information 3-7

ivCisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 5: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Contents

Deleting Zones, Zone Sets, and Members 3-7

Changing the Default Zone Policy 3-7

Viewing Zone Statistics 3-9

Managing VSANs 4-1

Adding and Configuring VSANs 4-1

Controlling In-Band Management Connectivity 4-4

Configuring IP Routing for Management Traffic 4-4

Managing IPFC Connectivity with Multiple VSANs 4-6

Viewing In-Band Management Information 4-7

Viewing IP Address Information 4-7

Enabling or Disabling IP Forwarding 4-7

Viewing TCP Information and Statistics 4-8

Viewing UDP Information and Statistics 4-9

Viewing IP Statistics 4-10

Viewing ICMP Statistics 4-12

Monitoring SNMP Traffic 4-14

Managing Administrator Access 5-1

Managing SNMP Users and Roles 5-1

Viewing SNMP Users, Roles, and Communities 5-1

Configuring SNMP Communities 5-3

Configuring User Roles 5-5

Role Views (Advanced) 5-7

Configuring RADIUS Security for CLI Access 5-8

Configuring RADIUS Authentication 5-8

Configuring RADIUS Servers 5-9

Managing Software and Configuration Files 6-1

Overview 6-1

Downloading Software Images 6-2

Copying Configuration Files 6-3

Saving Configurations 6-5

Managing Interfaces 7-1

Managing Ports 7-1

Enabling or Disabling Ports 7-1

Managing General Port Attributes 7-2

Managing Interface Attributes for Ports 7-4

Viewing FLOGI Attributes 7-5

vCisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 6: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Contents

Viewing Port ELP Attributes 7-7

Viewing Trunking Information 7-9

Managing Physical Attributes for a Port 7-10

Viewing Port Capability Attributes 7-11

Managing PortChannel Interfaces 7-12

Managing PortChannel General Attributes 7-12

Managing PortChannel Interface Attributes 7-14

Monitoring Port Statistics 7-16

Monitoring and Charting Traffic Statistics 7-16

Monitoring Port Traffic (Bytes) 7-17

Monitoring Port Traffic (Frames) 7-18

Monitoring Port Discards 7-18

Monitoring Port Class 2 Errors 7-19

Monitoring Port Link Errors 7-19

Monitoring Port Sequence Errors 7-20

Monitoring Port Frame Errors 7-21

Managing PortChannels 7-22

Managing Events and Alarms 8-1

Managing Events 8-1

Viewing the Events Log 8-2

Configuring Event Destinations 8-3

Configuring Event Security 8-5

Configuring Event Filters 8-6

Enabling RMON Alarms 8-7

Enabling RMON Alarms by Port 8-8

Enabling RMON Alarms for VSANs 8-9

Enabling RMON Alarms for Physical Components 8-10

Managing RMON Alarms and Events 8-10

Configuring RMON Controls 8-11

Managing RMON Alarms 8-11

Managing RMON Event Severity Levels 8-15

Viewing the RMON Log 8-16

Configuring the Call Home Feature 8-17

Overview of Features 8-17

Configuration Overview 8-17

Configuring Call Home Attributes 8-18

Configuring Call Home Destination Attributes 8-19

Configuring Call Home E-Mail Addresses 8-21

viCisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 7: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Contents

Configuring Call Home Alerts 8-21

Configuring Call Home Profiles 8-22

Configuring the Syslog 8-23

Configuring Syslog Attributes 8-24

Configuring Syslog Servers 8-25

Configuring Syslog Priorities 8-27

Managing the System and Components 9-1

Managing the Switch System 9-1

Viewing System Attributes 9-1

Viewing Running Processes 9-3

Viewing Flash File Information 9-4

Managing Inventory Information 9-4

Viewing Redundancy Information 9-5

Managing Card Attributes 9-6

Managing Temperature Sensor Information 9-7

Managing Power Supplies 9-7

Managing Fibre Channel Routing and FSPF 10-1

Configuring Fibre Channel Routing 10-1

Configuring Fibre Channel Routes 10-1

Configuring Fibre Channel Route Flows 10-3

Configuring FSPF 10-5

Managing FSPF General Attributes 10-6

Configuring FSPF Interfaces 10-7

Viewing FSPF Statistics 10-8

Viewing FSPF Interface Statistics 10-9

Viewing Link State Records 10-10

Viewing FSPF Links 10-11

Managing Advanced Features 11-1

Managing World Wide Names 11-1

Managing Domain Parameters 11-3

Managing Running Attributes for Domains 11-3

Configuring Domain Attributes 11-4

Viewing Domain Information 11-6

Viewing Domain Manager Statistics 11-6

Configuring Domain Interfaces 11-7

Viewing Domain Areas 11-8

Configuring Persistent FCIDs 11-8

viiCisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 8: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Contents

Viewing Domain Area Ports 11-10

Configuring the Name Server 11-10

Viewing General Attributes for the Name Server 11-10

Viewing Advanced Attributes for the Name Server 11-11

Proxy Ports for the Name Server 11-12

Viewing Name Server Statistics 11-13

Viewing LUN Information 11-13

Configuring LUN Discovery 11-13

Viewing Logical Unit Information 11-14

Viewing LUNs Information 11-15

Viewing RSCN Information 11-15

Viewing RSCN Nx Registrations 11-15

Viewing RSCN Statistics 11-16

Configuring Timers 11-16

Configuring Virtual Routing Redundancy Protocol (VRRP) 11-18

Configuring VRRP Operations Attributes 11-18

Managing IP Addresses for VRRP 11-20

Viewing VRRP Statistics 11-21

I N D E X

viiiCisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 9: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected].

Preface

This preface describes the audience, organization, and conventions of the Cisco MDS 9000 Family Fabric Manager User Guide. It also provides information on how to obtain related documentation.

AudienceThis guide is for system administrators who intend to use the Cisco Fabric Manager to configure and monitor the switches that build the network fabric.

You should be familiar with the basic concepts and terminology used in internetworking, and understand your network topology and the protocols that the devices in your network can use. You should also have a working knowledge of the operating system on which you are running Fabric Manager, such as Microsoft Windows, Linux, or Solaris.

OrganizationThis guide is organized as follows:

Chapter Title Description

Chapter 1 Getting Started with Cisco Fabric Manager

Provides an overview of the Cisco Fabric Manager system.

Chapter 2 Using Cisco Fabric Manager and Device Manager

Describes how to use the Cisco Fabric Manager views for performing the most important device and fabric management tasks.

Chapter 3 Managing Zones and Zone Sets Describes how to configure zones and zone sets.

Chapter 4 Managing VSANs Describes how to configure VSANs (virtual storage area networks).

Chapter 5 Managing Administrator Access Describes how to configure SNMP authentication, and how to set up RADIUS servers for authenticating command-line interface (CLI) access.

Chapter 6 Managing Software and Configuration Files

Describes how to manage configuration and image files.

ixCisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 10: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

PrefaceConventions

ConventionsThis guide uses the following conventions:

Note Means reader take note. Notes contain helpful suggestions or references to material not covered in the manual.

Caution Means reader be careful. In this situation, you might do something that could result in loss of data.

Related DocumentationRefer to the following documents for additional information:

• Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family

• Cisco MDS 9200 Series Hardware Installation Guide

• Cisco MDS 9500 Series Hardware Installation Guide

• Cisco MDS 9000 Family Configuration Guide

• Cisco MDS 9000 Family Command Reference

• Cisco MDS 9000 Family Fabric Manager User Guide

• Cisco MDS 9000 Family Troubleshooting Guide

Chapter 7 Managing Interfaces Describes how to view and configure physical port interfaces and PortChannels.

Chapter 8 Managing Events and Alarms Describes how to configure and monitor SNMP events (traps and informs), RMON alarms, Call Home alerts, and Syslog messaging.

Chapter 9 Managing the System and Components Describes how to monitor and configure the chassis and its components, including modules (line cards), temperature sensors, power supplies, and the fan assembly.

Chapter 10 Managing Fibre Channel Routing and FSPF

Describes how to configure Fibre Channel services, including Fibre Channel routes and flows, and FSPF (Fabric Shortest Path First) interfaces.

Chapter 11 Managing Advanced Features Describes how to configure advanced features, including:

• World wide names

• Domain parameters

• Name server

Chapter Title Description

xCisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 11: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

PrefaceObtaining Documentation

• Cisco MDS 9000 Family System Messages Guide

• Cisco MDS 9000 Family MIB Reference Guide

Obtaining DocumentationThese sections explain how to obtain documentation from Cisco Systems.

World Wide WebYou can access the most current Cisco documentation on the World Wide Web at this URL:

http://www.cisco.com

Translated documentation is available at this URL:

http://www.cisco.com/public/countries_languages.shtml

Documentation CD-ROMCisco documentation and additional literature are available in a Cisco Documentation CD-ROM package, which is shipped with your product. The Documentation CD-ROM is updated monthly and may be more current than printed documentation. The CD-ROM package is available as a single unit or through an annual subscription.

Ordering DocumentationYou can order Cisco documentation in these ways:

• Registered Cisco.com users (Cisco direct customers) can order Cisco product documentation from the Networking Products MarketPlace:

http://www.cisco.com/cgi-bin/order/order_root.pl

• Registered Cisco.com users can order the Documentation CD-ROM through the online Subscription Store:

http://www.cisco.com/go/subscription

• Nonregistered Cisco.com users can order documentation through a local account representative by calling Cisco Systems Corporate Headquarters (California, U.S.A.) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387).

Documentation FeedbackYou can submit comments electronically on Cisco.com. In the Cisco Documentation home page, click the Fax or Email option in the “Leave Feedback” section at the bottom of the page.

You can e-mail your comments to [email protected].

xiCisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 12: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

PrefaceObtaining Technical Assistance

You can submit your comments by mail by using the response card behind the front cover of your document or by writing to the following address:

Cisco SystemsAttn: Document Resource Connection170 West Tasman DriveSan Jose, CA 95134-9883

We appreciate your comments.

Obtaining Technical AssistanceCisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can obtain online documentation, troubleshooting tips, and sample configurations from online tools by using the Cisco Technical Assistance Center (TAC) Web Site. Cisco.com registered users have complete access to the technical support resources on the Cisco TAC Web Site.

Cisco.comCisco.com is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information, networking solutions, services, programs, and resources at any time, from anywhere in the world.

Cisco.com is a highly integrated Internet application and a powerful, easy-to-use tool that provides a broad range of features and services to help you with these tasks:

• Streamline business processes and improve productivity

• Resolve technical issues with online support

• Download and test software packages

• Order Cisco learning materials and merchandise

• Register for online skill assessment, training, and certification programs

If you want to obtain customized information and service, you can self-register on Cisco.com. To access Cisco.com, go to this URL:

http://www.cisco.com

Technical Assistance CenterThe Cisco Technical Assistance Center (TAC) is available to all customers who need technical assistance with a Cisco product, technology, or solution. Two levels of support are available: the Cisco TAC Web Site and the Cisco TAC Escalation Center.

Cisco TAC inquiries are categorized according to the urgency of the issue:

• Priority level 4 (P4)—You need information or assistance concerning Cisco product capabilities, product installation, or basic product configuration.

• Priority level 3 (P3)—Your network performance is degraded. Network functionality is noticeably impaired, but most business operations continue.

• Priority level 2 (P2)—Your production network is severely degraded, affecting significant aspects of business operations. No workaround is available.

xiiCisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 13: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

PrefaceObtaining Technical Assistance

• Priority level 1 (P1)—Your production network is down, and a critical impact to business operations will occur if service is not restored quickly. No workaround is available.

The Cisco TAC resource that you choose is based on the priority of the problem and the conditions of service contracts, when applicable.

Cisco TAC Web Site

You can use the Cisco TAC Web Site to resolve P3 and P4 issues yourself, saving both cost and time. The site provides around-the-clock access to online tools, knowledge bases, and software. To access the Cisco TAC Web Site, go to this URL:

http://www.cisco.com/tac

All customers, partners, and resellers who have a valid Cisco service contract have complete access to the technical support resources on the Cisco TAC Web Site. The Cisco TAC Web Site requires a Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or password, go to this URL to register:

http://www.cisco.com/register/

If you are a Cisco.com registered user, and you cannot resolve your technical issues by using the Cisco TAC Web Site, you can open a case online by using the TAC Case Open tool at this URL:

http://www.cisco.com/tac/caseopen

If you have Internet access, we recommend that you open P3 and P4 cases through the Cisco TAC Web Site.

Cisco TAC Escalation Center

The Cisco TAC Escalation Center addresses priority level 1 or priority level 2 issues. These classifications are assigned when severe network degradation significantly impacts business operations. When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC engineer automatically opens a case.

To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to this URL:

http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml

Before calling, please check with your network operations center to determine the level of Cisco support services to which your company is entitled: for example, SMARTnet, SMARTnet Onsite, or Network Supported Accounts (NSA). When you call the center, please have available your service agreement number and your product serial number.

xiiiCisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 14: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

PrefaceObtaining Technical Assistance

xivCisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 15: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected] documentation

Cisco MDS 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C H A P T E R 1

Getting Started with Cisco Fabric Manager

This chapter introduces the Cisco MDS 9000 Family Fabric Manager, provides background information, and describes how to start using the software. It includes the following sections:

• Managing Cisco MDS 9000 Family Switches, page 1-1

• Establishing Management Connectivity, page 1-4

• Performing Fabric Management, page 1-6

• Performing Device Management, page 1-8

• Accessing Cisco Fabric Manager, page 1-9

Managing Cisco MDS 9000 Family SwitchesThis section provides an overview of how you can use the Cisco Fabric Manager to manage Cisco MDS 9000 Family switches. It includes the following sections:

• Cisco MDS 9000 Fabric Manager, page 1-1

• Storage Management Solutions Architecture, page 1-2

• Managing Cisco MDS 9000 Switches, page 1-3

Cisco MDS 9000 Fabric ManagerThe Cisco Fabric Manager is a set of two network management tools that supports both version 2 and 3 of the Simple Network Management Protocol (SNMPv2 and SNMPv3). It provides a graphical user interface (GUI) that displays real-time views of your network fabric and lets you manage the configuration of Cisco MDS 9000 Family devices. The Cisco Fabric Manager tools are:

• Fabric Manager

• Device Manager

The Fabric Manager displays a map of your network fabric, including Cisco MDS 9000 Family switches, hosts, and storage devices. The Device Manager presents two views of a switch. Device View displays a graphic representation of the switch configuration and provides access to statistics and configuration information for a single switch. Summary View displays a summary of xEPorts (Inter-Switch Links), Fx Ports (fabric ports), and Nx Ports (attached hosts and storage) on the switch.

1-19000 Family Fabric Manager User Guide

Page 16: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 1 Getting Started with Cisco Fabric ManagerManaging Cisco MDS 9000 Family Switches

The Cisco Fabric Manager is an alternative to the command-line interface (CLI) for most switch configuration commands. For information on using the CLI to configure a Cisco MDS 9000 Family switch, refer to the Cisco 9000 Family Configuration Guide or the Cisco 9000 Family Command Reference.

Storage Management Solutions ArchitectureFigure 1-1 illustrates how the management services required for the storage environment can be divided into five “layers,” with the bottom layer being closest to the physical storage network equipment and the top layer managing the interface between applications and storage resources. The main Fabric Manager window is on the right, and Device Manager’s Device View is on the left.

Figure 1-1 Storage Management Solutions Architecture

Of these five layers of storage network management, Cisco Fabric Manager provides tools for device (element) management and fabric management. In general, the Device Manager is most useful for device management, while Fabric Manager is more efficient for performing fabric management operations involving multiple switches.

Tools for “upper-layer” management tasks can be provided by Cisco or by third-party storage and network management applications. The following summarizes the goals and function of each layer of storage network management:

• Device management provides tools to configure and manage a device within a system or a fabric. You use device management tools to perform tasks on one device at a time, such as initial device configuration, setting and monitoring thresholds, and managing device system images or firmware.

• Fabric management provides a system-oriented view of a fabric and its devices. Fabric management applications provide fabric discovery, fabric monitoring, reporting, and fabric configuration.

• Resource management provides tools for managing resources such as fabric bandwidth, connected paths, disks, I/O operations per second (IOPS), CPU, and memory.

Device management

Fabric management

Resourcemanagement

Datamanagement

Applicationmanagement

DatabasesERP

File systems

85043

1-2Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 17: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 1 Getting Started with Cisco Fabric ManagerManaging Cisco MDS 9000 Family Switches

• Data management provides tools for ensuring the integrity, availability, and performance of data. Data management services include redundant array of independent disks (RAID) schemes, data replication practices, backup or recovery requirements, and data migration.

• Application management provides tools for managing the overall system consisting of devices, fabric, resources, and data from the application. Application management integrates all these components with the applications that use the storage network.

Managing Cisco MDS 9000 SwitchesThe Cisco MDS 9000 Family of switches can be accessed and configured in many different ways, and support standard management protocols. The different protocols that are supported in order to access, monitor, and configure the Cisco MDS 9000 Family of switches are described in Table 1-1.

Table 1-1 Supported Management Protocols

Management Protocol Purpose

Telnet/SSH Provides remote access to the CLI for a Cisco MDS 9000 switch.

FTP/SFTP/TFTP Copies configuration and software images between devices.

SNMPv1, v2c, and v3 Includes over 50 distinct Management Information Bases (MIBs). Cisco MDS 9000 Family switches support SNMP version 1, 2, and 3 and RMON V1 and V2. RMON provides advanced alarm and event management, including setting thresholds and sending notifications based on changes in device or network behavior.

By default, the Cisco Fabric Manager communicates with Cisco MDS 9000 Family switches using SNMPv3, which provides secure authentication using encrypted user names and passwords. SNMPv3 also provides the option to encrypt all management traffic.

HTTP HTTP is only used for the distribution and installation of the Cisco Fabric Manager software. It is not used for communication between the Cisco Fabric Manager and Cisco MDS 9000 Family switches.

ANSI T11 FC-GS3 FC-GS3 in the definition of the management servers defines the Fabric Configuration Server (FCS), which is a standard mechanism to collect information about platforms (end devices) and interconnecting elements (switches) building the fabric.

The Cisco MDS 9000 uses the information provided by FCS on top of the information contained in the Name Server database and in the Firbe Channel Shortest Path First (FSPF) topology database to build a detailed topology view, and collect information for all the devices building the fabric.

1-3Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 18: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 1 Getting Started with Cisco Fabric ManagerEstablishing Management Connectivity

Establishing Management ConnectivityThis section describes how to establish management connectivity when using the Cisco Fabric Manager. It includes the following sections:

• In-Band Management and Out-of-Band Management, page 1-4

• Using the Local Console Port and the CLI, page 1-5

In-Band Management and Out-of-Band ManagementFigure 1-2 illustrates the in-band management and out-of-band management connections provided by Cisco MDS 9000 Family switches. As shown, the Cisco Fabric Manager requires an out-of-band (Ethernet) connection to at least one Cisco MDS 9000 Family switch.

Figure 1-2 Managing Cisco MDS 9000 Family Devices

The interface referred to as the out-of-band management connection is a 10/100 Mbps Ethernet interface on the supervisor module, labeled mgmt0. The mgmt0 interface can be connected to a management network to access the switch through IP over Ethernet. You must connect to at least one Cisco MDS 9000 Family switch in the fabric, through its Ethernet management port. You can then use this connection to manage the other switches using in-band (Fibre Channel) connectivity. Otherwise, you need to connect the mgmt0 port on each switch to your Ethernet network.

Each supervisor module has its own Ethernet connection; however, the two Ethernet connections in a redundant supervisor system operate in active or standby mode. The active supervisor module also hosts the active mgmt0 connection. When a failover event occurs to the standby supervisor module, the IP address and media access control (MAC) address of the active Ethernet connection are moved to the standby Ethernet connection.

You can also manage switches on a Fibre Channel network using an in-band IP connection (using IP over Fibre Channel - IPFC). The Cisco MDS 9000 Family supports RFC 2625 IP over Fibre Channel (IPFC), which defines an encapsulation method to trasnport IP over a Fibre Channel network.

Ethernetmanagement

network

Managment workstationCisco Fabric Manager

Out-of-bandmanagement

IP IPFC

IPFC

IPFC

In-bandmanagement

In-bandmanagement

In-bandmanagement

FibreChannel

Cisco MDS 9000family switch

Cisco MDS 9000family switch

Cisco MDS 9000family switch 85

044

1-4Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 19: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 1 Getting Started with Cisco Fabric ManagerEstablishing Management Connectivity

IPFC encapsulates IP packets into Fibre Channel frames so that management information can cross the Fibre Channel network without requiring a dedicated Ethernet connection to each switch. IP addresses are resolved to the Fibre Channel address through Address Resolution Protocol (ARP). This feature allows you to build a completely in-band management solution, in case of availability of servers mounting IP-enabled host bus adapters (HBAs).

Using the Local Console Port and the CLIThe first management interface you use to manage a Cisco MDS 9000 switch is the serial RJ-45 console connection on the supervisor module. This console connection provides access to the CLI and allows you to run the initial setup routine when you first turn on the switch.

You can use the CLI to perform many of the tasks you can perform using the Cisco Fabric Manager. However, complex tasks or tasks involving multiple switches may be easier to perform using the Cisco Fabric Manager. You need to use the CLI for the following tasks:

• Run the initial setup routine to complete the initial configuration required for establishing remote management connectivity

• Run debug and show commands for diagnostics and troubleshooting

• Write or run automated configuration scripts

For information about using the CLI, refer to the Cisco 9000 Family Configuration Guide and the Cisco 9000 Family Command Reference.

Figure 1-3 illustrates options for running the CLI with Cisco MDS 9000 Family switches.

Figure 1-3 Managing Cisco MDS 9000 Family Devices

When you connect to a Cisco MDS 9000 Family switch using the local console and start the switch for the first time, the system displays a setup routine that helps you perform the basic configuration required to manage and connect the switch to end nodes or other switches. The setup routine must be completed before you can connect to the switch or manage it using the Cisco Fabric Manager.

Ethernetmanagement

network

CLITelnet/SSH

Out-of-bandmanagement

IP IPFC

IPFC

IPFC

In-bandmanagement

In-bandmanagement

In-bandmanagement

FibreChannel

Cisco MDS 9000family switch

Cisco MDS 9000family switch

Cisco MDS 9000family switch 85

045

1-5Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 20: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 1 Getting Started with Cisco Fabric ManagerPerforming Fabric Management

The setup routine prompts for the following configuration values:

• Administrator password—you have the option to create a new login account or oeverwrite a pre-existing accound password.

• SNMPv3 user name and authentication password. SNMP community string.

• Switch name - This is your switch prompt.

• IP address for the switch's management interface - The management interface can be an out-of-band Ethernet interface or an in-band Fibre Channel interface.

• Subnet mask for the switch's management interface.

• The following IP addresses: Destination prefix, destination prefix subnet mask, and next hop IP address, if you want to enable IP routing. Also, provide the IP address of the default network. Otherwise, provide an IP address of the default gateway.

• DNS IP address (optional).

• Default domain name (optional).

• SSH service on the switch-if you wish to enable this service, then select the type of SSH key (dsa/rsa/rsa1) and number of key bits (768 to 2048).

• NTP server IP address (optional).

In addition to these settings, each Cisco MDS 9000 Family switch is configured with the following default values:

• VSAN membership—All ports are in VSAN 1

• Switch port speed and type—Autosense

Performing Fabric ManagementThis section describes the main tasks that you can perform with Fabric Manager and provides some background information for understanding how and when to implement a specific feature.

This section includes the following topics:

• Discovering and Viewing the Network Fabric, page 1-6

• Controlling Administrator Access with Users and Roles, page 1-7

Fabric Manager also provides a number of tools for troubleshooting connectivity between switches or between storage and end devices. For an overview of the options to use for performing all of these tasks, see Chapter 2, “Using Cisco Fabric Manager and Device Manager.”

Discovering and Viewing the Network FabricCisco Fabric Manager collects information on the fabric topology, sends SNMP queries to the SNMP agent running on the switch to which Fabric Manager is connected. The switch replies after having discovered all devices connected to the fabric by using the information coming from its FSPF technology database and the Name Server database, and collected using the Fabric Confguration Server’s request/response mechanisms defined by the FC-GS3 standard. When you start the Fabric Manager, you enter the IP address (or host name) of a “seed” switch.

After you start Fabric Manager and discovery completes, you see the Fabric Manager shown in Figure 1-4. It provides a view of your network fabric, including all discovered switches, hosts, and storage devices.

1-6Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 21: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 1 Getting Started with Cisco Fabric ManagerPerforming Fabric Management

Figure 1-4 Fabric Manager

You use the Fabric Manager to discover and view your fabric topology and to manage zones and zone sets. It is also convenient to use the Fabric Manager to manage other kinds of configuration involving more than one switch, such as VSANs and PortChannels. The following are some of the main fabric management tasks that you can perform using Fabric Manager:

• Managing zones and zone sets

• Managing VSANs

• Managing PortChannels

• Controlling management access with users and roles

Controlling Administrator Access with Users and RolesCisco MDS 9000 Family switches support role-based management access whether using the CLI or the Cisco Fabric Manager. This lets you assign specific management privileges to particular roles and then assign one or more users to each role.

Cisco Fabric Manager uses SNMPv3 to establish role-based management access. After completing the setup routine, a single role, user name, and password are established. The role assigned to this user allows the highest level of privileges, which includes creating new users and roles. Use the Cisco Fabric Manager to create roles, and users, and to assign passwords as required for secure management access in your network.

1-7Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 22: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 1 Getting Started with Cisco Fabric ManagerPerforming Device Management

To enable RADIUS authentication of CLI users or to establish SNMP users and roles, see Chapter 5, “Managing Administrator Access.”

Performing Device ManagementMost tasks that you can perform with Device Manager can also be performed for multiple switches using the Fabric Manager. However, Device Manager may be more convenient to use when you are working with a single switch. Also, the Device Manager provides more detailed information for verifying or troubleshooting device-specific configuration than what is available from the Fabric Manager.

When you start the Device Manager, you see the Device View, shown in Figure 1-5.

Figure 1-5 Device Manager’s Device View

The Device View provides a graphic representation of a Cisco MDS 9000 switch, including the installed switching modules, services modules, supervisor modules, and the status of each port within each module. You can use the Device View to perform any switch-level configuration tasks including the following:

1-8Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 23: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 1 Getting Started with Cisco Fabric ManagerAccessing Cisco Fabric Manager

• Manage ports, PortChannels, and trunking

• Manage SNMPv3 security access to switches

• Manage CLI security access to switches

• Manage alarms, events, and notifications

• Save and copy configuration files and software images

• View hardware configuration

• View chassis, module, and port status and statistics

Summary View provides a way of monitoring all of the ports on the switch, categorized by operative modes (Fx-Ports and E-Ports).

When you click the Summary tab on the Device Manager window, you see the Summary View shown in Figure 1-6. The Summary View provides summary information about the interfaces on a single switch.

Figure 1-6 Summary View

Accessing Cisco Fabric ManagerBefore you can access the Cisco Fabric Manager, you must complete the following tasks:

• A supervisor module must be installed on each switch that you want to manage.

• The supervisor module must be configured with the following values using the setup routine or the CLI:

– IP address assigned to the mgmt0 interface

– SNMPv3 user name and password, maintaining the same password for all the switches in the fabric (for information about managing SNMP security with the Fabric Manager, see Chapter 5, “Managing Administrator Access”

This section describes how to access the Cisco Fabric Manager. It includes the following topics:

1-9Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 24: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 1 Getting Started with Cisco Fabric ManagerAccessing Cisco Fabric Manager

• Connecting to a Supervisor Module, page 1-10

• Launching Views, page 1-11

• Troubleshooting Installation and Access, page 1-12

Connecting to a Supervisor ModuleThe Cisco Fabric Manager software executables reside on each supervisor module of each Cisco MDS 9000 Family switch in your network. The supervisor module provides an HTTP server that responds to browser requests and distributes the software to Windows or UNIX network management stations.

To install the software for the first time, or if you want to update or reinstall the software, access the supervisor module with a web browser. When you click the Install buttons on the web page that is displayed, the software running on your workstation is verified to make sure you are running the most current version of the software. If it is not current, the most recent version is downloaded and installed on your workstation.

To download and install the software on your workstation, follow these steps:

Step 1 Enter the IP address or host name of the supervisor module in the address or location field of your browser.

The supervisor module HTTP server displays the window shown in Figure 1-7.

Figure 1-7 Cisco MDS 9000 Family Supervisor Web Page

When you connect to the server for the first time, it checks to see if you have the correct Sun Java Virtual Machine version installed on your workstation. If not, a link is provided to the appropriate web page on Sun Microsystem’s website so you can install it.

Step 2 Click the link to the Sun Java Virtual Machine software (if required) and install the software.

Using the instructions provided by the Sun Microsystems website to reconnect to the supervisor module by reentering the IP address or host name in the Location or Address field of your browser.

Step 3 Click either installation link (Install Fabric Manager or Install Device Manager).

You see a prompt asking for permission to install the Java applets on your workstation, as shown in Figure 1-8.

1-10Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 25: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 1 Getting Started with Cisco Fabric ManagerAccessing Cisco Fabric Manager

Figure 1-8 Java Web Start Warning

Step 4 Click Start to begin installing the software.

The Java Web Start application is automatically downloaded and installed on your workstation. Once the installation is complete, you can start the Cisco Fabric Manager directly from the Fabric Manager icon or the Device Manager icon on your desktop, or from the options on the Windows Start menu.

Launching ViewsTo launch the Fabric Manager (Fabric View) or Fabric Device Manager (Device View and Summary View), follow these steps:

Step 1 Double-click the Fabric Manager icon or the Device Manager icon on your desktop or select the option from the Windows Start menu.

You see the login screen, shown in Figure 1-9.

Figure 1-9 Login Screen

1-11Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 26: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 1 Getting Started with Cisco Fabric ManagerAccessing Cisco Fabric Manager

Step 2 Enter the IP address or device name in the Device Name(s) field, or select an IP address from the list of previously accessed devices, accessible through the drop-down arrow to the right of the Device Name(s) field.

Step 3 Check the SNMPv3 check box to select SNMP version 3.

Note The default authentication digest used for storing user names and passwords is MD5. In case you selected SHA instead, the relative checkbox in the Fabric Manager initial login screen should be checked.

Step 4 Enter a user name and password.

Step 5 Enter the Privacy Password used for encrypting management traffic if the SNMPv3 Privacy option is enabled.

The Privacy option causes all management traffic to be encrypted while, with SNMPv3, user names and passwords are always encrypted.

To enable the Privacy option, see Chapter 5, “Managing Administrator Access.”

Step 6 Click Open.

You see either the Fabric Manager (Figure 2-1 on page 2-3) or the Device View (Figure 2-11 on page 2-21).

Troubleshooting Installation and AccessIf your network uses a proxy server for HTTP requests, make sure the Java Web Start Application Manager is properly configured with the IP address of your proxy server. To configure a proxy server in the Java Web Start Application Manager, follow these steps:

Step 1 Double-click the Java Web Start application manager icon on your Windows desktop, or Chose Program Files > Java Web Start.

Step 2 Select File > Preferences from the Java WebStart Application Manager.

Step 3 Click the Manual radio button and enter the IP address of the proxy server in the HTTP Proxy field.

Step 4 Enter the HTTP port number used by your proxy service in the HTTP Port field.

Step 5 Click OK.

Note For general problems installing or using the Fabric Manager software, refer to the Release Notes for the Cisco MDS 9000 Family. addlink

1-12Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 27: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected]

Cisco MDS 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C H A P T E R 2

Using Cisco Fabric Manager and Device Manager

This chapter describes how to use Cisco Fabric Manager and Device Manager, and it includes the following sections:

• Summary of Fabric and Device Management Tasks, page 2-1

• Using Fabric Manager, page 2-2

• Using Device Manager, page 2-19

• Using Summary View, page 2-26

Summary of Fabric and Device Management TasksTable 2-1 summarizes the tasks that you can perform using Fabric Manager and Device Manager. In general, you can perform tasks using Fabric Manager for multiple devices. Device Manager is more convenient to use when you are working with a single switch.

Table 2-1 Fabric and Device Management Tasks

Task Tool See

Troubleshoot connectivity and switch configuration.

Fabric Manager “Troubleshooting Switch Configuration” section on page 2-9

Perform fabric discovery and view network topology

Fabric Manager Chapter 1, “Getting Started with Cisco Fabric Manager”

Manage zones and activate zone sets Fabric Manager Chapter 3, “Managing Zones and Zone Sets”

Manage VSANs. Fabric Manager or Device Manager

Chapter 4, “Managing VSANs”

Enable or disable ports. Device Manager’s Device View “Managing Ports” section on page 2-24

Manage SNMP events and alarms. Fabric Manager or Device Manager

Chapter 8, “Managing Events and Alarms”

Manage SNMP and CLI Security Fabric Manager or Device Manager

Chapter 5, “Managing Administrator Access”

Copy and save configuration and image files

Fabric Manager or Device Manager

Chapter 6, “Managing Software and Configuration Files”

2-19000 Family Fabric Manager User Guide

Page 28: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Using Fabric ManagerThis section describes how to use Fabric Manager and summarizes the tasks that you can perform with it. It includes the following sections:

• Fabric Mangaer Main Window, page 2-2

• Locating Other Switches, page 2-6

• Modifying Device Grouping, page 2-7

• Troubleshooting Switch Configuration, page 2-9

• Setting Preferences, page 2-14

• Viewing Reports in Fabric Manager, page 2-16

Fabric Mangaer Main WindowThe Fabric Manager displays a view of your network fabric, including Cisco 9000 or third-party switches and end devices. To launch the Fabric Manager from your desktop, double-click the Fabric Manager icon and follow the instructions described in the “Launching Views” section on page 1-11. Figure 2-1 shows the Fabric Manager main window.

Note Changes made using Fabric Manager are applied to the running configuration of the switches you are managing and the changes may not be saved when the switch restarts. After you make a change to the configuration or perform an operation (such as activating zones), the system prompts you to save your changes before you exit.

View hardware configuration Fabric Manager or Device Manager

Chapter 9, “Managing the System and Components”

Manage Fibre Channel routing and FSPF. Fabric Manager or Device Manager

Chapter 10, “Managing Fibre Channel Routing and FSPF”

Manage advanced features Fabric Manager or Device Manager

Chapter 11, “Managing Advanced Features”

Table 2-1 Fabric and Device Management Tasks (continued)

Task Tool See

2-2Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 29: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Figure 2-1 Fabric Manager Main Window

The menu bar at the top of the Fabric Manager window provides access to options, that are organized by menus. The toolbar provides icons that duplicate the most commonly used options on the File, Tools, and Help menus.

The main window has a menu bar, toolbar, message bar, status bar, and three panes:

• VSAN/Switch pane—Displays a tree of configured VSANs and zones on the VSANs/Zones tab and a menu tree of available configuration tasks on the Switch tab.

• Information pane—Displays information about whatever option is selected in the menu tree.

• Map pane—Displays a map of the network fabric, including switches, hosts, and storage. It also provides tabs for displaying log and event data.

You can resize each pane by dragging the boundaries between each region or by clicking the Minimize or Maximize controls. (See Figure 2-1.)

2-3Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 30: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Menu Bar, Toolbars, and Message Bar

The menu bar at the top of the Fabric Manager window provides options for managing and troubleshooting the current fabric and for controlling the display of information on the Map pane. The menu bar provides the following menus:

• File—Open a new fabric, rediscover the current fabric, locate switches, set preferences, print the map, and clear or export the Map pane log.

• Edit—Manage zones, zonesets, and various elements on the Fabric Manager map.

• View—Change the appearance of the map (these options are duplicated on the Map pane toolbar).

• Reports—Display summary reports, as described in the “Viewing Reports in Fabric Manager” section on page 2-16.

• Troubleshooting—Verify and troubleshoot connectivity and configuration, as described in the “Troubleshooting Switch Configuration” section on page 2-9.

• Help—Display on-line help topics for specific dialog boxes in the Information pane.

The Fabric Manager main toolbar provides buttons for accessing the most commonly used menu bar options. The Map pane toolbar provides buttons for managing the appearance of the map. The Information pane toolbar provides buttons for editing and managing the Information pane.

The message bar shows the last entry displayed by the discovery process, and the possible error message. It displays a dialog stating that something has changed in the fabric and a new discovery is needed. The status bar shows both short-term, transient messages (such as the number of rows displayed in the table), and long-term discovery issues.

VSAN/Switch Pane

Use the VSAN tab on the VSAN/Switch pane to manage VSANs and zones in the currently discovered fabric. For information about managing VSANs see Chapter 4, “Adding and Configuring VSANs.”

To manage zones, right-click one of the folders in the VSAN tree and click Edit Zones from the pop-up menu. You see the Edit Zones dialog box. For information about managing zones and zone sets, see Chapter 3, “Managing Zones and Zone Sets.”

Use the Switch tab on the VSAN/Switch pane to display a menu tree of the options available for managing the switches in the currently discovered fabric. You see the menu tree shown in Figure 2-2.

2-4Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 31: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Figure 2-2 Menu Tree and Dialog Box

To select an option, click a folder to display the options available and then click the option. You see the dialog box for the selected option in the Information pane. The menu tree provides the following main folders:

• Physical—View and configure hardware components.

• Interface—View, monitor, and configure ports and PortChannel interfaces.

• FC—View and configure Fibre Channel network configurations.

• IP—View and configure TCP/IP (management) network configurations.

• Events—View and configure events, alarms, thresholds, notifications, and informs.

• Security—View and configure SNMP and CLI security.

• Admin—Download software images; copy and save configuration files.

Information Pane

The Information pane displays tables or other information associated with the option selected from the menu tree. The Information pane toolbar provides buttons for performing one or more of the following operations:

• Create—Insert a new row into a table.

• Delete Row—Delete the selected row from a table.

• Copy…Ctrl+C — Copy data from one row to another.

• Paste…Ctrl +V—Paste the data from one row to another.

• Apply Changes—Apply configuration changes.

Note After making changes you must save the configuration or the changes will be lost when the device is restarted.

• Refresh Values—Refresh table values.

• Undo Changes…Ctrl-Z—Undo the most recent change.

• Print Table —Print the contents of the Information pane.

• Export—Export and save information to a tab-delimited file.

2-5Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 32: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

• Log—Displays messages describing system operations, such as fabric discovery.

Note The buttons that appear on the toolbar vary according to the option you select. They are activated or deactivated (grayed) according to the field or other object that you select in the Information pane.

Map Pane

There are three tabs on the bottom of the Map pane:

• Map—Displays a graphical view of the network fabric with switches, hosts, and storage subsystems.

• Events—Displays information about the SNMP traps received by the management station.

When you right-click an icon, you see a pop-up menu with options that vary depending on the type of icon selected. The various options available for different objects include the following:

• Open an instance of Device Manager for the selected switch.

• Open a CLI session for the selected switch.

• Copy the display name of the selected object.

• Execute a ping or traceroute command for the device.

• Show or hide end devices.

• Create or delete an enclosure.

• Set the VSAN ID for an edge port (link).

• Set the trunking mode for an ISL.

• Create or add to a PortChannel for selected ISLs.

The Map pane has its own toolbar with options for saving, printing, and changing the appearance of the map. When you right-click on the map, a pop-up menu appears that provides options (duplicated on the toolbar) for changing the appearance of the map.

Note When a VSAN, zone, or zone member is selected in the VSAN tree, the map highlighting changes to identify the selected objects. To remove this highlighting, click the Clear Highlight button on the Map pane toolbar or choose Clear Highlight from the pop-up menu.

Locating Other SwitchesThe Locate Switches option uses SNMPv2 and discovers devices responding to SNMP requests with the read-only community string public. To enable your Cisco MDS 9000 Family switches to respond to SNMPv2 requests, see Chapter 5, “Managing Administrator Access.”

To locate switches that are not included in the currently discovered fabric, follow these steps:

Step 1 Choose File > Locate Switches from the Fabric View main window.

You see the Locate Devices dialog box.

Step 2 Enter a range of specific addresses belonging to a specific subnet which limit the research for the switches. To look for a Cisco MDS 9000 switch belonging to subnet 192.168.199.0, use the follwing string:

2-6Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 33: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

192.168.100.[1-254]

Multiple ranges can be specified, separated by commas. For example, to look for all the devices in the two subnets 192.168.199.0 and 192.169.100.0, use the following string:

192.168.100.[1-254], 192.169.100.[1-254]

Step 3 Enter the appropriate read community string in the Read Community field.

The default value for this string is “public.”

Step 4 Click Display Cisco MDS 9000 Only to display only the Cisco MDS 9000 Family switches in your network fabric.

Step 5 Click Search to discover switches and devices in your network fabric. You see the results of the discover in the Locate Devices window.

Note The number in the lower left corner of the screen increments as the device locator attempts to discover the devices in your network fabric. When the discovery process is complete, the number indicates the number of rows displayed.

To manage the discovered switches, follow these steps:

Step 1 Choose File > Open from the Fabric Manager menu bar.

Step 2 Enter the IP address of a switch in the Device Name field on the Open dialog box.

Step 3 Enter your user name and password in the User Name and Auth Password fields.

If the SNMPv3 Privacy feature is implemented, enter the encryption password as well.

Step 4 Check the SNMPv3 check box to select SNMP version 3.

Step 5 Click Open.

Modifying Device GroupingBecause of not all the devices are capable of responding to FC-GS3 requests, different ports of a single server or storage subsystem may be displayed as individual end devices on the Fabric Manager map. To group end devices in a single enclosure in order to have them represented by a single icon on the map, follow these steps:

Step 1 Select the end devices in the Fabric Manager map (optional).

Step 2 Choose Edit > Map > Create Enclosure from the Fabric Manager menu bar.

You see the window shown in Figure 2-3.

2-7Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 34: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Figure 2-3 Create Enclosure Window

Step 3 Enter a name to identify the new icon on the Fabric Manager Map pane in the Name field.

Step 4 Select the type of icon to use for Type:

• host—Servers and other devices containing host bus adapters (HBAs)

• storageDevice—Storage enclosures

• gateway—Routers

Step 5 Enter the IP address of the device in the IpAddress field (optional).

Step 6 Select the ports on the target device connected to the Cisco MDS 9000 switch in the NxPort(s) field.

The list of all ports in a fabric that are not already assigned to en enclosure are shown.

Step 7 Check the FabricWide checkbox if you want the information about the enclosure to be distributed across the fabric, in order to guarantee uniqueness for the enclosure in the all fabric for a particular VSAN. To keep the enclosure information locally on the configured switch and not have it propagated on the fabric, uncheck the FabricWide checkbox.

Step 8 Click OK.

Note To delete an enclosure, choose Edit > Map > Delete Enclosure from the menu bar.

Note To change an existing enclosure, delete the enclosure and create a new one.

2-8Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 35: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Troubleshooting Switch ConfigurationThis section describes how to use the tools provided by the Fabric Manager and Device Manager to verify and troubleshoot fabric connectivity and switch configuration. It includes the following sections:

• Analyzing Switch Device Health, page 2-9

• Analyzing End-to-End Connectivity, page 2-10

• Analyzing Switch Fabric Configuration, page 2-11

• Analyzing the Results of Merging Zones, page 2-12

• Using Other Troubleshooting Tools, page 2-13

Analyzing Switch Device Health

The Switch Health option lets you determine the status of the components of a specific switch.

To use the Switch Health option, follow these steps:

Step 1 Click Switch Health from the Fabric Manager Troubleshooting menu.

You see the window shown in Figure 2-4.

Figure 2-4 Switch Health Analysis Window

Step 2 Click Start to identify any problems that may currently be affecting the selected switch.

The Switch Health Analysis window displays any problems affecting the selected switches.

Step 3 Fix these problems.

Step 4 Click Clear to remove the contents of the Switch Health Analysis window.

Step 5 Click Close to close the window.

2-9Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 36: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Analyzing End-to-End Connectivity

You can use the End to End Connectivity option to determine connectivity and routes among devices with the switch fabric. The connectivity tool checks to see that every pair of end devices can talk to each other, using a Ping test and by determining if they are in the same VSAN or in the same active zone.

This option uses versions of the ping and traceroute commands modified for Fibre Channel networks.

To use this option, follow these steps:

Step 1 Choose Troubleshooting > End to End Connectivity from the Fabric Manager menu bar.

You see the window shown in Figure 2-5.

Figure 2-5 End to End Connectivity Analysis Window

Step 2 Enter the identifier of the VSAN in which you want to verify connectivity in the VSAN field.

Step 3 Identify any latency issues in the network fabric by clicking the option, Report average latencies greater than and entering the number of microseconds.

Step 4 Click Ensure that members can communicate to perform a Fibre Channel ping between the selected end points.

Step 5 Identify the number of packets, the size of each packet, and the timeout in milliseconds.

Step 6 Analyze the redundant paths between endpoints by clicking Ensure that redundant paths exist between members.

Step 7 Click Analyze.

The End to End Connectivity Analysis window displays the selected end points with the switch to which each is attached, and the source and target ports used to connect it.

The output shows all the requests which have failed. The possible descriptions are:

• Ignoring empty zone—No requests are issued for this zone.

• Ignoring zone with single member—No requests are issued for this zone.

• Source/Target are unknown—No nameserver entries exist for the ports or we have not discovered the port during discovery.

• Both devices are on the same switch.

• No paths exist between the two devices.

• VSAN does not have an active zone set and the default zone is denied.

2-10Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 37: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

• Average time ... micro secs—The latency value was more than the threshold supplied.

Step 8 Click Clear to remove the contents of the window.

Step 9 Click Close to close the window.

Analyzing Switch Fabric Configuration

The Fabric Configuration option lets you analyze the configuration of a switch by comparing the current configuration to a specific switch or to a policy file. You can save a switch configuration to a file and then compare all switches against the configuration in the file.

To use the Fabric Configuration option to analyze the configuration of a switch, follow these steps:

Step 1 Click Fabric Configuration from the Fabric Manager Troubleshooting menu.

You see the window shown in Figure 2-6.

Figure 2-6 Fabric Configuration Analysis Window

Step 2 Choose if you want to compare the selected switch to another switch or to a Policy File.

• If you are making a switch comparison, click Switch and then click the drop-down arrow to see a list of switches.

• If you are making a policy comparison, click Policy File. Then the button to the right of this option to browse your file system and select a policy file (*.XML).

Step 3 Click Rules to set the rules to apply when running the Fabric Configuration Analysis tool.

You see the window shown in Figure 2-7.

2-11Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 38: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Figure 2-7 Fabric Configuration Rules

Step 4 Change the default rules as required and click OK.

Step 5 Click Compare.

The system analyzes the configuration and displays issues that arise as a result of the comparison.

Step 6 Click Clear to remove the contents of the window.

Step 7 Click Close to close the window.

You use a policy file to define the rules to be applied when running the Fabric Configuration Analysis tool. When you create a policy file, the system saves the rules selected for the selected switch.

To create a policy file, follow these steps:

Step 1 Choose Tools > Fabric Configuration from the Fabric Manager menu bar.

Step 2 Click Policy File and enter a name for the policy in the field provided.

Step 3 Click Create Policy and confirm the operation when prompted.

Analyzing the Results of Merging Zones

You can use the Zone Merge option on the Fabric Manager Troubleshooting menu to determine if two connected switches have compatible zone configurations.

To use the Zone Merge option, follow these steps:

Step 1 Choose Zone Merge from the Fabric Manager Troubleshooting menu.

You see the window shown in Figure 2-8.

2-12Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 39: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Figure 2-8 Zone Merge Analysis Window

Step 2 Select a switch from each pull-down list.

Step 3 Identify the VSAN for which you want to perform the zone merge analysis.

Step 4 Click Analyze.

The Zone Merge Analysis window displays any inconsistencies between the zone configuration of the two selected switches.

Step 5 Click Clear to remove the contents of the window.

Step 6 Click Close to close the window.

Using Other Troubleshooting Tools

You can use the following options on the Troubleshooting menu to verify connectivity to a selected object or to open other management tools:

• Traceroute—Verify connectivity between two end devices that are currently selected on the Map pane.

• Device Manager— Launch the Device Manager for the switch selected on the Map pane.

• Command Line Interface—Open a Telnet or SSH session for the switch selected on the Map pane.

To use the Traceroute option to verify connectivity, follow these steps:

Step 1 Select two or more endpoints on the Fabric Manager map.

Step 2 Click Traceroute from the Troubleshooting menu, or right-click one of the endpoints and click Traceroute from the pop-up menu.

You see the window shown in Figure 2-9.

2-13Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 40: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Figure 2-9 Traceroute Window

Step 3 Change the timeout value if the default (30 seconds) is too short or too long.

Step 4 Click OK.

The results of the Traceroute operation appear in the Results box.

Setting PreferencesTo set your preferences for the behavior of the Fabric Manager, choose File > Preferences from the Fabric Manager menu bar. You see the dialog box shown in Figure 2-10.

Figure 2-10 Fabric View Preferences

2-14Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 41: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

This dialog box has the following four tabs, which let you set your preferences for different components of the application:

• General

• SNMP

• Discovery

• Map

Table 2-2 describes the configurable attributes on each tab.

Table 2-2 Fabric Manager Preferences—Configurable Attributes

Attributes Effect

General tab

Confirm Row Deletion The system prompts you and requires a confirmation before deleting any row in a table.

Show Switch DNS Name The DNS host names (if any) for switches are displayed in the map and in tables.

Show WorldWideName (WWN) Vendor

• replace

• prepend

Show the vendor portion of the world wide name, either instead of the node portion (replace) or preceding that portion (prepend)

Show Timestamps as Date/Time Show the time of events in Date/Time format.

Use Secure Shell(sshclient) instead of Telnet Use SSH when making a console (CLI) connection to a device. The field below this radio button allows you to identify the location of the SSH application that you want to use.

Snmp tab

Retry requests Specifies the number of times an SNMP request will be issued.

Enable status polling every Specifies the length of time (in seconds) between SNMP polling requests.

Trace SNMP packets in Log Capture SNMP queries/replies in the Fabric Manager log.

Register for Events after Open, listen on Port 2162

Causes the system to listen for fabric events and display the changes automatically or prompt you to start a new discovery.

Discovery tab

Trace Topology Discovery in Log Enable the logging of discovery messages in the Fabric View log.

Use FCS Discovery Cache Cache FCS discovery information instead of rediscovering the information every time.

Use DNS Name if No Management IP Address Use any DNS name found during discovery if no management IP addess is configured for the device.

Max FCS Vsan Discovery Time Specifies the time (in seconds) to allow discovery of a single VSAN.

2-15Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 42: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Viewing Reports in Fabric ManagerThe Fabric Manager provides a series of tables grouped under the Reports menu. To open the tables to view this information, click Reports on the Fabric Manager menu bar and select one of the following options:

• ISL Statistics, page 2-16

• ISLs, page 2-17

• Switches, page 2-17

• Hosts, page 2-18

• Storage, page 2-18

• LUNs, page 2-19

When you select one of these options, you see the available information in tabular form in the Information pane of the Fabric Manager main window. The following sections describe the tables provided by each option.

ISL Statistics

Choose Reports > ISL Statistics from the Fabric Manager menu bar to display information about the Inter-Switch Links in the currently discovered fabric. See Table 2-3.

Max Lun Discovery Time Specifies the time (in seconds) to allow discovery of a single LUN.

Map tab

Display End Devices Displays end devices in the Fabric Manager map.

Display Node Labels Display node labels in the Fabric Manager map.

Collapse Loops Collapse private or public loops in the Fabric Manager map.

Collapse Multiple Links Collapse multiple links between devices into a single line in the Fabric Manager map.

Table 2-2 Fabric Manager Preferences—Configurable Attributes (continued)

Attributes Effect

Table 2-3 Reports > ISL Statistics

Field Description

Between: Switch Displays the IP address or host name of the switch from which the link originates.

Between: Interface Displays the interface from which the link originates.

And: Switch Displays the IP address or host name of the switch to which the link is destined.

And: Interface Displays the interface to which the link is destined.

Speed Displays the maximum bandwidth (in Mbits per second) of the link.

2-16Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 43: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

You can use the controls at the top of the table to change the following report parameters:

• Poll interval

• Scale

ISLs

Choose Reports > ISLs from the Fabric Manager menu bar to display information about the Inter-Switch links in the currently discovered fabric. See Table 2-4.

Switches

Choose Reports > Switches from the Fabric Manager menu tree to display information about the switches in the currently discovered fabric. See Table 2-5.

Bandwidth %: Between Displays the percentage of bandwidth utilized on the originating link.

Bandwidth %: And Displays the percentage of bandwidth utilized on the destination link.

Errors Displays the number of errors occurring on the link.

Discards Displays the number of frames discarded on the link.

Table 2-3 Reports > ISL Statistics (continued)

Field Description

Table 2-4 Reports > ISLs

Field Description

Between: Switch Displays the IP address or host name of the switch from which the link originates.

Between: Interface Displays the interface from which the link originates.

And: Switch Displays the IP address or host name of the switch to which the link is destined.

And: Interface Displays the interface to which the link is destined.

Mode Displays the mode of the ISL trunk.

Speed Displays the maximum bandwidth of the link.

Vsan: Port Displays the VSAN to be configured on the interface from which the ISL originates.

Vsan: Active Displays the active VSANs on the link in case trunking is enabled.

Vsan: Allowed(Between) Displays the allowed VSANs on the interface from where the ISL is generated in case trunking is enabled.

Vsan: Allowed(And) Displays the allowed VSANs on the interface to where the ISL is destined, in case truning is enabled.

2-17Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 44: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Fabric Manager

Hosts

Choose Reports > Hosts from the Fabric Manager menu tree to display information about the hosts in the currently discovered fabric. See Table 2-6.

Storage

Choose Reports > Storage from the Fabric Manager menu tree to display information about the links to hosts and storage in the currently discovered fabric. See Table 2-7.

Table 2-5 Reports > Switches

Field Description

Name Displays the host name of the switch.

IP Address Displays the IP address of the switch.

Vendor Displays the manufacturer of the switch, as derived from the hardware address of the device.

Model Displays the model of the switch (if discovered).

Release Displays the release of the switch software.

WWN Displays the world wide name (WWN) of the switch.

Table 2-6 Reports > Hosts

Field Description

Name Displays the name of the host.

IP Address Displays the IP address of the host.

Vsan Displays the VSAN to which the host belongs.

Port WWN Displays the Nx Port WWN for this host.

Attached To Displays the switch name and Fx port through which this host is connected to the fabric.

Table 2-7 Reports > Storage

Field Description

Name Displays the assigned name for the selected storage device.

IP Address Displays the IP address assigned to the selected storage device.

Vsan Displays the VSAN containing the selected storage device.

Port WWN Displays the Port WWN of the storage device interface.

FcId Displays the Fibre Channel ID of the storage device interface.

Attached To Displays the switch through which the selected device is attached.

Type Displays the type of the storage device.

Vendor Displays the vendor name for the selected storage device.

ProductID Displays the product ID of the storage device.

2-18Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 45: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Device Manager

LUNs

Choose the Reports > LUNs option from the Fabric Manager menu tree to display information about the LUNs in the currently discovered fabric. See Table 2-8.

Using Device ManagerThis section describes how to use the Device Manager to manage the configuration of specific devices. It includes the following sections:

• Overview of Device Manager, page 2-20

• Launching Device Manager from Fabric Manager, page 2-20

• Comparing Device Manager to Fabric Manager, page 2-21

• Managing Ports, page 2-24

RevLevel Displays the revision level of the software running on the storage device.

Details Displays other information that may be available about the storage device.

Total Capacity (M) Displays the total capacity in Mbytes for the selected storage device.

Number LUNs Displays the number of LUNs on the selected storage device.

Table 2-7 Reports > Storage (continued)

Field Description

Table 2-8 Reports > LUNs

Field Description

Port WWN Displays the Port WWN of the storage device interface where the LUN is exported.

Fcid Displays the Fibre Channel identifier of the storage device interface where the LUN is exported.

Attached To Displays the switch through which the LUN is connected.

Number Displays the numerical identifier of the LUN.

Capacity Displays the capacity (in Mbytes) of the LUN.

SerialNum Displays the serial number of the LUN device.

2-19Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 46: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Device Manager

Overview of Device ManagerDevice Manager provides a physical representation of your switch chassis, with the modules, ports, power supplies, and fan assemblies (Figure 2-11). The menu bar at the top of the Device Manager window provides access to options, organized into menus that correspond to the menu tree in Fabric Manager (Figure 2-12).

The legend at the bottom right of the Device Manager indicates port status, as follows:

• Green—The port is up.

• Brown—The port is administratively down.

• Red—The port is down or has failed.

• Gray—The port is unreachable.

Launching Device Manager from Fabric ManagerDevice Manager gives a graphic representation of a Cisco MDS 9000 Family switch, including the installed switching modules, the supervisor modules, the power supplies, and the status of each port within each module.

To launch the Device Manager from your desktop, double-click the Device Manager icon and follow the instructions described in the “Launching Views” section on page 1-11.

To launch Device Manager from Fabric Manager , right-click the switch you want to manage on the Fabric Manager map and click Device Manager from the pop-up menu that appears. The Device Manager main window is shown in Figure 2-11.

Device Manager can also be started by double-clicking on a switch in the Fabric Manager topology view.

2-20Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 47: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Device Manager

Figure 2-11 Device Manager, Deview Tab

Comparing Device Manager to Fabric ManagerAs shown in Figure 2-12, the menu bar at the top of the Device Manager contains the same menus as the Fabric Manager menu tree.

2-21Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 48: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Device Manager

Figure 2-12 Device Manager Menu Bar Compared to the Fabric Manager Menu Tree

For information about the options provided by these menus, see the “VSAN/Switch Pane” section on page 2-4. The Device menu, which is unique to the Device View and Summary View, provides the following options:

• Open—Open the Device Manager for a different switch.

• Open Last—Open the Device Manager for the most recently managed switch.

• Preferences—Set management preferences for controlling the behavior and appearance of the Device Manager.

• Refresh—Update the current display.

• Message Log—Display messages regarding the current operation of the Device Manager application.

• Command Line Interface—Open a Telnet/SSH session with the current switch.

• Exit—Close the Device Manager application.

As shown in Figure 2-13, the tables in the Fabric Manager correspond to the dialog boxes that appear in Device Manager. However, the Fabric Manager tables show values for multiple switches and so the first column identifies the specific switch. The Device Manager dialog box shows values for a single switch, while the Fabric Manager shows the same values for one or more switches.

2-22Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 49: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Device Manager

Figure 2-13 Device Manager Dialog Box Compared to Fabric Manager

The toolbar on the Device Manager dialog box provides the same options as the toolbar on the Information pane in Fabric Manager , as summarized here:

• Create—Insert a new row into a table (if applicable).

• Delete Row—Delete the selected row from a table (if applicable).

• Copy…Ctrl+C — Copy data from one row to another.

• Paste…Ctrl +V—Paste the data from one row to another.

• Apply Changes—Apply configuration changes.

Note After making changes you must save the configuration the changes will be lost when the device is restarted.

• Refresh Values—Refresh table values.

• Reset Changes…Ctrl-Z—Undo the most recent change.

• Print table…— Print the contents of the Information pane.

Tip You can copy values from one cell in a table to the rest of the column. Copy the value to the clipboard, hold down the shift key while pressing the down arrow key (or click on the bottom cell in the column). Then paste the value to all the selected cells and click Apply.

When you click the Create button, you see a dialog box that lets you enter the values required for the specific table. Figure 2-14 shows dialog boxes for creating a new VSAN. As you can see the fields and options are the same from both views, but the appearance of the window may vary slightly. For instance, the dialog box from Fabric Manager may have an option for selecting a specific switch, while the dialog box from Device Manager may have additional port-level detail.

2-23Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 50: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Device Manager

Figure 2-14 Create Dialog Boxes in Fabric Manager and Device Manager

Managing Ports

Tip You can select multiple ports in Device Manager and apply options to all the selected ports at one time. Either select the ports by dragging the mouse around them, or hold down the shift key and click on each port.

To enable or disable a port, right-click the port and click Enable or Disable from the pop-up menu. To enable or disable multiple ports, drag the mouse to select the ports and then right-click the selected ports. Then click Enable or Disable from the pop-up menu.

To manage trunking on one or more ports, right-click the ports and click Configure. On the dialog box that appears, in the Trunk column, right-click the current value and click nonTrunk, trunk, or auto from the pull-down list.

To create PortChannels using Device Manager, click PortChannels from the Interface menu. For detailed instructions, see the “Managing PortChannel Interfaces” section on page 7-12. You can also use Fabric Manager to conveniently create a PortChannel.

Note To create a PortChannel, all the ports on both ends of the link must have the same port speed, trunking type, and administrative state.

Setting PreferencesTo set your preferences for the behavior of the Device Manager application, choose Preferences from the Device menu. You see the dialog box shown in

2-24Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 51: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Device Manager

Figure 2-15 Device Manager Preferences

Table 2-9 describes the configurable attributes on this dialog box.

Table 2-9 Fabric Manager Preferences—Configurable Attributes

Attributes Effect

General tab

Retry requests Specifies the number of times an SNMP request will be issued.

Enable status polling every Specifies the length of time (in seconds) between SNMP polling requests.

Trace SNMP packets in Message Log Capture SNMP packets in the message log.

Register for Events after Open, listen on Port 2162

Causes the system to listen for events and display changes in port status.

Confirm Row Deletion The system prompts you and requires a confirmation before deleting any row in a table.

Show WorldWideName (WWN) Vendor

• replace

• prepend

Show the vendor portion of the world wide name, either instead of the node portion (replace) or preceding that portion (prepend)

Show Timestamps as Date/Time Show the time of events in Date/Time format.

Use Secure Shell(sshclient) instead of Telnet Use SSH when making a console (CLI) connection to a device. The field below this radio button allows you to identify the location of the SSH application that you want to use.

Show Tooltips in Device View Show tooltips for different graphic elements in the Device Manager .

2-25Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 52: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Summary View

Using Summary ViewClick the Summary tab on the Device Manager main window to see a summary of xEPorts, FxPorts, and NxPorts on a single switch. Figure 2-16 shows the Summary View.

Figure 2-16 Summary View

The Summary View displays attributes for a single switch, such as port speed, link utilization, and other traffic statistics. It has the same menu bar and toolbar buttons as the Device View.

To monitor traffic for selected objects, click the Monitor icon. To display detailed statistics for selected objects, click the Detailed Statistics icon.

The Summary View provides the same menus and options that are available from the Device View and shows the display-only information described in Table 2-10.

Table 2-10 Summary View Display-Only Attributes

Display-Only Attribute Description

CPU % Displays percentage of CPU utilization for the active supervisor module.

Disk % Displays percentage of disk utilization for the active supervisor module.

Memory % Displays percentage of memory utilization for the active supervisor module.

xEPorts (Inter-Switch Links)

Port Displays the port ID.

2-26Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 53: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Summary View

Channel Displays the channel ID.

Speed Displays port speed.

ActiveVsans Displays active VSANs.

Nbr Switch WWN Displays the neighbor switch world wide name (WWN).

Rx Utilization% Displays the percentage of receive transmission utilization or bandwidth.

Tx Utilization% Displays the percentage of transmit utilization or bandwidth.

Errors Displays the errors for this link.

Discards Displays the frames (or packets) discarded for this link.

FxPorts (Switch Side)

Port Displays the port ID.

Speed Displays port speed.

VSAN Displays the VSAN to which this port is assigned.

Rx Utilization% Displays the percentage of receive transmission utilization or bandwidth.

Tx Utilization% Displays the percentage of transmit utilization or bandwidth.

Errors Displays the errors for this link.

Discards Displays the frames (or packets) discarded for this link.

NxPorts (Attached Hosts and Storage)

Port Displays the port ID.

Type Displays the device type; for example, disk, node, etc.

Node WWN Displays the WWN for this node.

Port WWN Displays the WWN for this port.

Fcid Displays the Fibre Channel ID for this port.

Table 2-10 Summary View Display-Only Attributes (continued)

Display-Only Attribute Description

2-27Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 54: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 2 Using Cisco Fabric Manager and Device ManagerUsing Summary View

Table 2-11 describes the configurable attributes on the Summary View.

Table 2-11 Summary View—Configurable Attributes

Configurable Attribute Description

Poll Interval Sets polling intervals at:

• 10 or 30 seconds

• 1, 5, or 30 minutes

• 1 hour

Scale% Specifies when the Rx and Tx bars should change from green to orange (warning) to red (danger) in the inline bar chart feature.

For example, setting the orange scale to 50% indicates that the Rx and Tx bars should change from green to orange when Rx and Tx utilization exceeds 50%.

2-28Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 55: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected]

Cisco MDS 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C H A P T E R 3

Managing Zones and Zone Sets

The Fabric Manager allows you to configure and monitor zones and zone sets (groups of zones) on theCisco 9000 switch. Zoning allows you to set up access control between hosts and storage devices. You can use zones to control access between devices or user groups, and to increase network security and prevent data loss or corruption.

This chapter describes how to configure and monitor zones and zone sets using the Zone Server and the Zone Manager, which are available from the Fabric Manager.

Note Zones and zone sets can only be created and configured in the Fabric Manager.

To verify the compatibility of the zone configuration on two connected switches, see “Analyzing the Results of Merging Zones” section on page 2-12. For information about zones and zone sets, and configuring them using the command-line interface (CLI), refer to the Cisco 9000 Family Configuration Guide.

This chapter includes the following sections:

• Creating Zones and Zone Sets, page 3-1

• Adding Zones to a Zone Set, page 3-4

• Cloning Zones and Zone Sets, page 3-4

• Assigning Zone Members, page 3-5

• Activating or Enforcing Zone Sets, page 3-6

• Managing Zones, page 3-6

Creating Zones and Zone SetsZones are configured within VSANs, but you can configure zones without configuring any VSANs by configuring them within the default VSAN. The VSANs/Zones tab (see Figure 3-1) displays the VSANs configured in the currently discovered fabric.

3-19000 Family Fabric Manager User Guide

Page 56: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 3 Managing Zones and Zone SetsCreating Zones and Zone Sets

Figure 3-1 VSAN/Zones Tab

Note Zone information must always be identical for all the switches in the network fabric.

To manage zones and zone sets, select a Zone Set folder or click No Active Zones in the VSAN pane and then click the Edit VSAN button on the main toolbar. You can also choose Zones from the Fabric View Edit menu bar or right-click a zone folder in the VSANs/Zones tab and choose Edit Zones from the pop-up menu.

You see the Edit Zones dialog box for the current VSAN in the Information pane. (See Figure 3-2.) This window displays zone information for a specific switch. You can change zone information for the specific switch and when you click Activate, this configuration is distributed to the other switches in the network fabric.

Note When you confirm the activate operation, the current running configuration is saved to the startup configuration. This permanently saves any changes made to the running configuration (not just zoning changes).

3-2Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 57: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 3 Managing Zones and Zone SetsCreating Zones and Zone Sets

Figure 3-2 Edit Zones Dialog Box

Each VSAN contains a default zone, which by default, contains all connected devices assigned to the VSAN. Storage or host devices in a default zone do not belong to any other zone and, by default, are denied access to any other devices. You can change the default zone policy for any VSAN by choosing FC > Default Zone Policies from the Fabric View menu tree. However, we recommend that you establish connectivity among devices by assigning them to a nondefault zone.

The active zone set is shown in italic type. After you have made changes to the active zone set and before you activate the changes, the zone set is shown in boldface italic type. The tooltip for each zone indicates the activation time or modification time.

To create additional zones and zone sets, follow these steps:

Step 1 Choose the Zones folder and click the Insert button on the Information pane toolbar, or right-click the Zones folder and choose Insert from the pop-up menu.

Step 2 Enter the zone name in the dialog box that appears and click OK to add the zone.

The zone is automatically added to the zone database.

Step 3 Select a ZoneSets folder in the Edit Zones dialog box and click the Insert button on the toolbar to create a zone set.

You can also right-click the ZoneSets folder and choose Insert from the pop-up menu.

3-3Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 58: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 3 Managing Zones and Zone SetsAdding Zones to a Zone Set

Adding Zones to a Zone SetTo add a zone to a zone set, on the Edit Zones window, drag and drop the zone to the folder for the zone set. Alternatively, follow these steps:

Step 1 Click the ZoneSets folder and then click the Insert button on the Information pane toolbar.

You can also right-click the folder for the zone set to which you want to add a zone and choose Insert from the pop-up menu.

You see the Zone Server Select Zone dialog box shown in Figure 3-3.

Figure 3-3 Zone Server Select Zone

Step 2 Select the zone that you want to add to the zone set and click Add.

The zone is added to the zone set in the zone database.

Cloning Zones and Zone SetsAnother method of adding zones and zone sets is to clone existing zones and zone sets. To clone a zone or zone set, follow these steps:

Step 1 Click the Zones or ZoneSets folder and then click the Clone button on the Information pane toolbar.

You can also right-click the folder for the zone or zone set that you want to clone and choose Clone from the pop-up menu.

Step 2 Enter the name of the cloned zone or zone set.

By default, the dialog displays the selected zone as ClonedZone1.

Step 3 Click OK to add the cloned zone to the zone database.

3-4Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 59: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 3 Managing Zones and Zone SetsAssigning Zone Members

Assigning Zone MembersOnce you have created a zone, you can assign members to the zone. You can assign members using the following port identification types:

• pWWN—The world wide name of the port configured on the end device (in hex format).

• Fabric port WWN—The world wide name of the fabric port on the switch (in hex format).

• FC alias—The alias name in alphabetic characters (for example, Payroll).

• LUN—The logical unit number of a disk in a disk device.

For more information about port identification types, refer to the Cisco 9000 Family Configuration Guide.

To assign members to a zone, follow these steps:

Step 1 Click the folder for the zone and then click the Insert button on the Information pane toolbar, or right-click the folder and choose Insert from the pop-up menu.

You see the window shown in Figure 3-4.

Figure 3-4 Zone Server Add Member in Vsan

Step 2 Click the button to the right of the NxPort WWN field.

You see Zone Server Select Port in Vsan dialog box shown in Figure 3-5.

Figure 3-5 Zone Server Select Port in Vsan

Step 3 Select one of the ports in the VSAN and click OK to add it to the zone.

You see member in the Zone Server database in the left frame.

3-5Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 60: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 3 Managing Zones and Zone SetsActivating or Enforcing Zone Sets

Step 4 Repeat these steps to add other members to the zone.

Activating or Enforcing Zone SetsOnce zones and zone sets have been created and populated with members, you must activate or enforce the zone set.

Note Only one zone set can be activated at any time.

If zoning is activated, any member that is not assigned to an active zone belongs to the default zone. If zoning is not activated, all members belong to the default zone.

To activate a zone set, follow these steps:

Step 1 Click the zone set in the Edit Zone dialog box.

Step 2 Click Activate.

You see the zone set in the Active Zone Set folder.

Note If one zone set is active and you activate another zone set, the currently active zone set is automatically deactivated.

Managing ZonesThis section describes how to configure and monitor zones from the Zone Server and includes the following sections:

• Searching the Zone Database, page 3-6

• Displaying Port Membership Information, page 3-7

• Deleting Zones, Zone Sets, and Members, page 3-7

• Changing the Default Zone Policy, page 3-7

• Viewing Zone Statistics, page 3-9

Searching the Zone DatabaseTo search the zone or active zone set databases, follow these steps:

Step 1 Click the Find button on the Information pane toolbar.

You see the window shown in Figure 3-6.

3-6Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 61: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 3 Managing Zones and Zone SetsManaging Zones

Figure 3-6 Find in Database Dialog Box

Step 2 Enter the name of the member to be searched for.

Step 3 Click the From: Selection or Start radio button.

Step 4 Check either the Ignore Case or Exact Match check box.

Step 5 Click Next to launch the search.

Displaying Port Membership InformationTo display port membership information for members assigned to zones, click a member within a zone and then click the Port Membership button on the toolbar, or right-click the member and choose Port Membership from the pop-up menu.

You see the window shown earlier (see Figure 3-5).

Select a row and click OK.

Note The default zone members are explicity listed only when the default zone policy is configured as permit. When the default zone policy is configured as deny, the members of this zone are not shown. For more information, see the “Changing the Default Zone Policy” section on page 3-7.

Deleting Zones, Zone Sets, and MembersTo delete zones, zone sets, or members, click the object in the Information pane and click the Delete button on the toolbar, or right-click the object and choose Delete from the pop-up menu. The selected object is deleted from the zone database.

Changing the Default Zone PolicyEach member in the fabric can belong to any zone. If a member does not belong to any zone, it is part of the default zone. If no zone has been activated in the fabric, all members belong to the default zone. Even though a member can belong to multiple zones, a member in the default zone cannot be part of any other zone.

Traffic can be permitted and denied to members in the default zone. This information is not distributed to all switches. Permission and denial must be set for each switch in the fabric.

To permit or deny traffic to members in the default zone from the Zone Server, follow these steps:

3-7Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 62: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 3 Managing Zones and Zone SetsManaging Zones

Step 1 Choose FC > Default Zone Policy from the Fabric Manager menu tree.

You see the dialog box shown in Figure 3-7. This dialog box displays the default zone behavior for multiple switches.

Figure 3-7 FC > Default Zone Policy Dialog Box, Fabric Manager

Step 2 Click the DefaultZoneBehavior field and choose either permit or deny from the pull-down menu.

The dialog box shows the display-only information described in Table 3-1.

Table 3-2 describes the configurable attributes for zone policy.

Table 3-1 Fabric > Default Zone Policy—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan Displays the VSAN ID.

Table 3-2 Fabric > Zone Server > Defaults—Display-Only Attributes

Display-Only Attribute Description

DefaultZoneBehaviour Specifies whether the default zone policy is to permit or deny access.

SetPropagationMode Specifies one of the following propagation modes when sending zoneset information to other switches:

• FullZoneSet causes the full zoneset information to be sent.

• ActiveZoneSet causes only the active zoneset information to be sent.

Note To preserve zoneset changes after the switches restart, save the running configuration of each affected switch to the startup configuration using the Admin > Copy Configuration option from the menu tree.

3-8Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 63: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 3 Managing Zones and Zone SetsManaging Zones

Viewing Zone StatisticsTo monitor zone statistics from the Zone Server, choose FC > Zone Statistics from the Fabric Manager menu tree. You see the window shown in Figure 3-8. This view displays zone statistics for multiple switches.

Figure 3-8 FC > Zone Statistics Dialog Box

The dialog box shows the display-only attributes described in Table 3-3.

Table 3-3 Fabric > Zone Server > Stats—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch number.

Vsan Displays the VSAN ID.

Merge Requests—Tx Displays the number of merge request frames sent by this zone server to other zone servers in the fabric on this VSAN.

Merge Requests—Rx Displays the number of merge request frames received by this zone server from other zone servers in the fabric on this VSAN.

Merge Accepts—Tx Displays the number of merge accept frames sent by this zone server to other zone servers in the fabric on this VSAN.

Merge Accepts—Rx Displays the number of merge accept frames received by this zone server from other zone servers in the fabric on this VSAN.

Change Requests—Tx Displays the number of change requests sent by this zone server to other zone servers in the fabric on this VSAN.

Acquire change authorization requests Stage fabric configuration update requests

Update fabric config request Release change authorization requests

Change Requests—Rx Displays the number of change requests received by this zone server from other zone servers in the fabric on this VSAN.

Acquire change authorization requests Stage fabric configuration update requests

Update fabric config request Release change authorization requests

3-9Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 64: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 3 Managing Zones and Zone SetsManaging Zones

Change Accepts—Tx Displays the number of change responses sent by this zone server to other zone servers in the fabric on this VSAN.

Acquire change authorization accept Stage fabric configuration update accept

Update fabric config accept Release change authorization accept frames

Change Accepts—Rx Displays the number of change responses received by this zone server from other zone servers in the fabric on this VSAN.

Acquire change authorization accept Stage fabric configuration update accept

Update fabric config accept Release change authorization accept frames

GS3—TxRejects Displays the number of FC-GS3 requests rejected by this zone server on this VSAN.

GS3—RxRejects Displays the number of FC-GS3 requests received by this zone server on this VSAN.

Table 3-3 Fabric > Zone Server > Stats—Display-Only Attributes (continued)

Display-Only Attribute Description

3-10Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 65: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected] documentation

Cisco MDS 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C H A P T E R 4

Managing VSANs

VSANs (virtual SANs) allow you to separate devices that are physically connected to the same fabric, and thus provide higher security and greater scalability in the network fabric. When you create VSANs, you are creating multiple logical SANs over a common physical infrastructure. After creating VSANs, you must establish IP static routes between the network segments if you are using the IP over Fibre Channel (IPFC) protocol to manage your Cisco MDS 9000 Family switches.

The Fabric Manager allows you to configure VSANs on multiple Cisco 9000 switches. The Device Manager allows you to configure VSANs on a single Cisco 9000 switch. This chapter describes how to configure VSANs using the Fabric Manager and the Device Manager.

Note For information about VSANs and configuring them using the command-line interface (CLI), refer to the Cisco 9000 Family Configuration Guide.

You can manage Cisco MDS 9000 Family switches through Ethernet connections to the management interface (mgmt 0) of each switch or by using the IPFC protocol. To use IPFC, you connect to a switch using the Ethernet management interface and establish routes from that switch to the other switches over the Fibre Channel network. When you segment the Fibre Channel network using VSANs, you must establish static routes between the network segments.

This chapter includes the following sections:

• Adding and Configuring VSANs, page 4-1

• Controlling In-Band Management Connectivity, page 4-4

Adding and Configuring VSANsFigure 4-1 shows a physical Fibre Channel network with two VSANs. VSAN 2 is connected by dashed lines and VSAN 7 is connected by solid lines.

4-19000 Family Fabric Manager User Guide

Page 66: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsAdding and Configuring VSANs

Figure 4-1 Configuring VSANs

VSAN 2 includes the H1 and H2 hosts, the AS2 and AS3 application servers, and the SA1 and SA4 storage arrays. VSAN 7 connects H3, AS1, SA2, and SA3. The four switches in this network are interconnected by trunk links that carry both VSAN 2 and VSAN 7 traffic.

VSAN 1 is the default VSAN for Cisco MDS 9000 Family switches. All ports are assigned by default to VSAN 1. VSAN 4094 is called the isolated VSAN. When a VSAN is deleted, any ports in that VSAN are moved to VSAN 4094.

Note We recommend that you delete or move all the ports in a VSAN before deleting the VSAN.

VSANs are enabled through trunking, which enables interconnect ports to transmit and receive frames in more than one VSAN over a single physical link, using the Extended Inter-Switch Link (EISL) protocol. The trunking protocol is enabled by default, and if disabled on a switch, no ports on that switch or directly connected to the switch will support the use of VSANs.

By default, the trunk mode is enabled on all Fibre Channel interfaces, but can be disabled on a port-by-port basis. When connected to a third-party switch, the trunk mode configuration has no effect—the ISL is always in a trunking disabled state.

Each Fibre Channel interface has an associated trunk-allowed VSAN list. This list determines the VSANs that are supported on each interface. By default, the entire range of VSANs from 1 through 4093 are allowed on any interface. You can restrict an interface to the use of a specific set of VSANs, which prevents traffic from any other VSAN being transmitted on the interface.

4-2Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 67: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsAdding and Configuring VSANs

To add and configure VSANs from the Fabric Manager, choose FC > VSAN from the menu tree. Figure 4-2 shows the FC > VSAN dialog box from the Fabric Manager. This view displays VSAN attributes for multiple switches.

Figure 4-2 FC > VSANs Dialog Box, Fabric Manager

To manage VSANs from Device Manager, choose the VSAN option from the FC menu or click the VSAN icon on the toolbar. The dialog box in the Device Manager displays VSAN general attributes for a single switch.

Both dialog boxes show the display-only information described in Table 4-1.

Table 4-2 lists the attributes that you can configure for the VSAN.

Table 4-1 FC > VSANs—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Index Displays the VSAN ID.

Mtu Displays the MTU (maximum transmission unit) of the VSAN. Normally, this attribute is 2112 for all VSANs with a Fibre Channel media type.

Table 4-2 FC > VSANs—Configurable Attributes

Configurable Attribute Description

Name Specifies the name of the VSAN.

State Specifies the state of the VSAN. Valid states are active and suspended.

InorderDelivery Enables InorderDelivery for the VSAN. Check the checkbox to guarantee that packets are delivered in order.

LoadBalancingType Specifies the type of load balancing used on this VSAN.

PortMembership Specifies the ports assigned to this VSAN.

4-3Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 68: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

To add a VSAN from Fabric Manager, click Create on the Information pane toolbar. To add a VSAN from Device Manager, click Create on the FC > VSAN dialog box. You see the dialog box shown in Figure 4-3.

Figure 4-3 Create VSANs

Complete the fields on this dialog box and click OK to add the VSAN.

Controlling In-Band Management ConnectivityThe Fabric Manager allows you to configure and monitor IP traffic on multiple Cisco MDS 9000 Family switches. The Device Manager allows you to configure and monitor IP traffic on a single Cisco 9000 switch.

Cisco MDS 9000 Family switches support both out-of-band and in-band management schemes. An Ethernet connection provides out-of-band management using Telnet, SSH or SNMP access. In-band IP management is also available using IP over Fibre Channel (IPFC). IPFC encapsulates IP packets into Fibre Channel frames so that management information can cross the Fibre Channel network without requiring a dedicated Ethernet connection to each switch. IP addresses are resolved to the Fibre Channel address through the Address Resolution Protocol (ARP).

This section includes the following topics:

• Configuring IP Routing for Management Traffic, page 4-4

• Managing IPFC Connectivity with Multiple VSANs, page 4-6

• Viewing In-Band Management Information, page 4-7

Configuring IP Routing for Management TrafficWhen using in-band network management over Fibre Channel links, you must ensure that a path exists from the seed switch, connected to the Cisco Fabric Manager over its Ethernet interface (mgmt0), and the other switches in the network fabric. See Figure 4-4.

4-4Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 69: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

Figure 4-4 IP Routing Between VSANs

To do this, make sure that the seed switch has a path to each VSAN. Each of the other switches can then be configured to use the seed switch as their default gateway. For example, in Figure 4-4, switch 1 is connected to VSAN 2 and VSAN 3, while switch 2 and switch 3 are configured to use switch 1 as their default gateway.

You can also configure static routes on a point-to-point basis from one switch to another. In this example, you would configure a static route on both switch 2 and switch 3 to switch 1.

To configure an IP route or identify the default gateway, choose IP Routes from the Device Manager IP menu. You see the window shown in Figure 4-5.

Figure 4-5 IP Routes

Table 4-3 describes the configurable attributes for IP routes.

VSAN 1VSAN 2

8544

6

IP = 192.168.1.1VSAN 1Switch 1

IP = 192.168.3.1VSAN 3

IP = 192.168.2.1VSAN 2

Switch 3Switch 2

Seedswitch

VSAN 1VSAN 2VSAN 3

VSAN 1VSAN 3

Ethernetmanagement

network

Cisco FabridManager

Fibre Channel network

Table 4-3 IP > IP Routes—Configurable Attributes

Configurable Attribute Description

Destination Specifies the destination for the route.

Mask Specifies the mask for the interface.

Gateway Specifies the default gateway for the switch.

Metric Specifies the primary routing metric for this route.

Interface Specifies the interface that exchanges management traffic.

4-5Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 70: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

To create a new IP route or identify the default gateway on a switch, click the Create button.

You see the window shown in Figure 4-6.

Figure 4-6 Create IP Routes

Complete the fields on this window and click OK to add an IP route.

To configure a static route, enter the destination network ID and subnet mask in the Dest and Mask fields. To configure a default gateway, enter the IP address of the seed switch in the Gateway field.

Managing IPFC Connectivity with Multiple VSANsTo configure IPFC, choose VSAN from the Device Manager FC menu and click the IP FC tab.

The IP > IP FC dialog boxes show the display-only information described in Table 4-4.

Table 4-4 FC > VSAN > IP FC—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

VSAN Displays the VSAN ID.

IpAddress/Mask Displays the IP address and mask for the interface.

FcId Displays the Fibre Channel identifier for this interface.

Status—Oper Displays the current operational status of the interface. Valid values are up, down, and disabled.

Status—Cause Displays the cause for the current operational status.

4-6Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 71: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

Table 4-5 describes the configurable attributes for IPFC.

Viewing In-Band Management InformationThis section describes how to monitor different types of IP management traffic over the Fibre Channel network. It includes the following topics:

• Viewing IP Address Information, page 4-7

• Enabling or Disabling IP Forwarding, page 4-7

• Viewing TCP Information and Statistics, page 4-8

• Viewing UDP Information and Statistics, page 4-9

• Viewing IP Statistics, page 4-10

• Viewing ICMP Statistics, page 4-12

• Monitoring SNMP Traffic, page 4-14

Viewing IP Address Information

To view IP addresses of the switches in the current fabric, choose IP > Addresses from the Fabric Manager menu tree. The dialog box from displays IP address information for multiple switches.

Enabling or Disabling IP Forwarding

To view or change the IP forwarding configuration of the switches in the current fabric, choose IP > Forwarding from the Fabric Manager menu tree. The dialog box shows the display-only and configurable attributes described in Table 4-7.

Table 4-5 FC > VSAN > IP FC—Configurable Attributes

Configurable Attribute Description

Mtu Specifies the maximum transmission unit (MTU)- for the interface.

Admin Specifies the desired state of the interface. Valid values are up and disabled.

Table 4-6 IP > IP Addresses

Attribute Description

Switch Displays the identity of the switch.

Interface, IpAddress Displays the interface on the switch and the IP address assigned to it.

MaskLength Displays the length of the subnet mask assigned to the interface.

4-7Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 72: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

To enable IP forwarding for a specific switch, click the RoutingEnabled check box.

Viewing TCP Information and Statistics

To view TCP information from the Device Manager, choose TCP/UDP from the IP menu. The dialog box shows the display-only attributes described in Table 4-8.

To monitor TCP statistics from the Fabric Manager, choose IP > Statistics > TCP from the menu tree. To monitor TCP statistics from the Device Manager, choose Statistics from the IP menu and view the TCP tab. The dialog boxes in Fabric Manager and Device Manager show the display-only attributes described in Table 4-9.

Table 4-7 IP > IP Addresses

Attribute Description

Switch Displays the identity of the switch.

RoutingEnabled Determines if IP forwarding is enabled on the switch.

Table 4-8 IP > TCP/UDP > TCP—Display-Only Attributes

Display-Only Attribute Description

Local IP, Port, Remote IP, Port Displays the local IP port ID and remote IP port ID.

State Displays the state of the TCP connection.

Table 4-9 IP > Statistics > TCP—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the identity of the switch (Fabric Manager only).

ActiveOpens Displays the number of times TCP connections have made a direct transition from the CLOSED state to the SYN-SENT state.

PassiveOpens Displays the number of times TCP connections have made a direct transition from the LISTEN state to the SYN-RCVD state.

AttemptFails Displays the number of times TCP connections have made a direct transition from either the SYN-SENT state or the SYN-RCVD state to the CLOSED state.

Also displays the number of times TCP connections have made a direct transition from the SYN-RCVD state to the LISTEN state.

4-8Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 73: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

Viewing UDP Information and Statistics

To view User Datagram Protocol (UDP) information from the Device Manager, choose TCP/UDP from the IP menu and click the UDP tab. The dialog box shows the display-only attributes described in Table 4-10.

To monitor UDP traffic from the Fabric Manager, choose IP > Statistics > UDP from the menu tree. To monitor UDP statistics from Device Manager, choose Statistics from the IP menu and click the UDP tab.

The Fabric Manager dialog box displays TCP traffic information for multiple switches. The Device Manager dialog box displays information for a single switch. Both dialog boxes show the display-only attributes described in Table 4-11.

EstabResets Displays the number of times TCP connections have made a direct transition from either the ESTABLISHED state or the CLOSE-WAIT state to the CLOSED state.

InSegs Displays the total number of segments received, including those received in error. This count includes segments received on currently established connections.

OutSegs Displays the total number of segments sent, including those on current connections but excluding those containing only retransmitted octets.

RetransSegs Displays the total number of segments retransmitted; that is, the number of TCP segments transmitted containing one or more previously transmitted octets.

InErrs Displays the total number of segments received in error; for example, bad TCP checksums.

OutRsts Displays the number of TCP segments sent containing the RST (reset) flag.

Table 4-9 IP > Statistics > TCP—Display-Only Attributes (continued)

Display-Only Attribute Description

Table 4-10 IP > TCP/UDP > UDP—Display-Only Attributes

Display-Only Attribute Description

IpAddress Displays the IP address of the UDP listener.

Port Displays the local port number of the UDP listener.

4-9Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 74: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

Viewing IP Statistics

To monitor statistics from the Fabric Manager, choose IP > Statistics > IP. The Fabric Manager dialog box displays IP statistics for multiple switches.

To monitor IP statistics from Device Manager, select Statistics from the IP menu and click the IP tab. The Device Manager dialog box displays information for a single switch.

Both dialog boxes show the display-only attributes described in Table 4-12.

Table 4-11 IP > Statistics > UDP—Display-Only Attributes

Display-Only Attribute Description

InDatagrams Displays the total number of UDP datagrams delivered to UDP users.

NoPorts Displays the total number of UDP datagrams received for which there was no application at the destination port.

InErrors Displays the number of UDP datagrams received that could not be delivered for reasons other than the lack of an application at the destination port.

OutDatagrams Displays the total number of UDP datagrams sent.

Table 4-12 IP > Statistics > IP—Display-Only Attributes

Display-Only Attribute Description

InReceives Displays the total number of input datagrams received from interfaces, including those received in error.

InHdrErrors Displays the number of input datagrams discarded due to errors in their IP headers, including:

• Bad checksums

• Version number mismatch

• Format errors

• Time-to-live exceeded

• Errors discovered in processing their IP options

4-10Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 75: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

InAddrErrors Displays the number of input datagrams discarded because the IP address in their IP header's destination field was not a valid address to be received.

This count includes invalid addresses (for example, 0.0.0.0) and addresses of unsupported classes (for example, class E).

For devices that are not IP routers and do not forward datagrams, this counter includes datagrams discarded because the destination address was not a local address.

ForwDatagrams Displays the number of input datagrams for which this device was not their final IP destination. As a result, an attempt was made to find a route to forward them to that final destination.

In devices that do not act as IP routers, this counter includes only those packets that were source-routed through this device and the source-route option processing was successful.

InUnknownProtos Displays the number of locally addressed datagrams that were received successfully, but were discarded because of an unknown or unsupported protocol.

InDiscards Displays the number of input IP datagrams for which no problems were encountered to prevent their continued processing, but which were discarded (for example, for lack of buffer space).

This counter does not include any datagrams discarded while awaiting reassembly.

InDelivers Displays the total number of input datagrams that were delivered successfully to IP user protocols, including Internet Control Message Protocol (ICMP).

OutRequests Displays the total number of IP datagrams supplied to IP by local IP user protocols (including ICMP), during requests for transmission.

This counter does not include any datagrams counted in the ForwDatagrams attribute.

Table 4-12 IP > Statistics > IP—Display-Only Attributes (continued)

Display-Only Attribute Description

4-11Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 76: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

Viewing ICMP Statistics

To monitor statistics for ICMP packets received, select IP > Statistics > ICMP > In from the Fabric Manager menu tree. To monitor statistics for ICMP packets transmitted from the Fabric Manager, select IP > Statistics > ICMP > Out from the Fabric Manager menu tree.

To monitor ICMP statistics from Device Manager, select Statistics from the IP menu and click the ICMP tab.

OutDiscards Displays the number of output IP datagrams for which no problem was encountered to prevent their transmission to their destination, but which were discarded (for example, for lack of buffer space).

This counter includes datagrams counted in the ForwDatagrams attribute, if any of these packets meet the discard criterion.

OutNoRoutes Displays the number of IP datagrams discarded because no route could be found to transmit them to their destination.

This counter includes any packets counted in the ForwDatagrams attribute, which meet this no-route criterion. This includes any datagrams that a host cannot route because all of its default routers are down.

FragOKs Displays the number of IP datagrams that have been successfully fragmented.

FragFails Displays the number of IP datagrams that have been discarded because they needed to be fragmented, but could not be; for example, because their “Don't Fragment” flag was set.

FragCreates Displays the number of IP datagram fragments that have been generated as a result of fragmentation.

ReasmReqds Displays the number of IP fragments received that needed to be reassembled.

ReasmOKs Displays the number of IP datagrams reassembled successfully.

ReasmFails Displays the number of failures detected by the IP reassembly algorithm, due to timeout or errors.

This is not necessarily a count of discarded IP fragments, because some algorithms can lose track of the number of fragments by combining them as they are received.

Table 4-12 IP > Statistics > IP—Display-Only Attributes (continued)

Display-Only Attribute Description

4-12Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 77: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

The Fabric Manager dialog box displays information for multiple switches. The Device Manager dialog box displays information for a single switch.

Table 4-13 describes the information displayed by both dialog boxes. In the Device Manager, a prefix (In or Out) identifies whether the packets are received or transmitted. In the Fabric Manager, separate dialog boxes are provided for incoming and outbound ICMP traffic and this prefix is omitted.

Table 4-13 IP > Statistics > ICMP—Display-Only Attributes

Display-Only Attribute Description

InSrcQuenchs Displays the number of ICMP source quench messages received.

InRedirects Displays the number of ICMP redirect messages received.

InEchos Displays the number of ICMP echo request messages received.

InEchoReps Displays the number of ICMP echo reply messages received.

InTimestamps Displays the number of ICMP timestamp request messages received

InTimestampReps Displays the number of ICMP timestamp reply messages received.

InAddrMasks Displays the number of ICMP address mask request messages received.

InAddrMaskReps Displays the number of ICMP address mask reply messages received.

InParmProbs Displays the number of ICMP parameter problem messages received.

InDestUnreachs Displays the number of ICMP destination unreachable messages received.

InTimeExcds Displays the number of ICMP time exceeded messages received.

OutSrcQuenchs Displays the number of ICMP source quench messages sent.

OutRedirects Displays the number of ICMP redirect messages sent. For a host, this attribute is always zero (0), because hosts do not send redirects.

OutEchos Displays the number of ICMP echo request messages sent.

OutEchoReps Displays the number of ICMP echo reply messages sent.

OutTimestamps Displays the number of ICMP timestamp request messages sent.

OutTimestampReps Displays the number of ICMP timestamp reply messages sent.

OutAddrMasks Displays the number of ICMP address mask request messages sent.

4-13Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 78: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

Monitoring SNMP Traffic

To monitor statistics from the Fabric Manager, select IP > Statistics > SNMP. To monitor SNMP traffic from Device Manager, select Statistics from the IP menu and click the SNMP tab.

The Fabric Manager dialog box displays information for multiple switches. The Device Manager dialog box displays information for a single switch. Both dialog boxes show the display-only attributes described in Table 4-14.

OutAddrMaskReps Displays the number of ICMP address mask reply messages sent.

OutParmProbs Displays the number of ICMP parameter problem messages sent.

OutDestUnreachs Displays the number of ICMP destination unreachable messages sent.

OutTimeExcds Displays the number of ICMP time exceeded messages sent.

Table 4-13 IP > Statistics > ICMP—Display-Only Attributes (continued)

Display-Only Attribute Description

Table 4-14 IP > Statistics > SNMP—Display-Only Attributes

Display-Only Attribute Description

InPkts Displays the total number of messages delivered by the transport service.

InBadVersions Displays the total number of SNMP messages for an unsupported version of SNMP that were delivered.

InBadCommunityNames Displays the total number of SNMP messages delivered that used an unknown SNMP community name.

InBadCommunityUses Displays the total number of SNMP messages that represented an SNMP operation that was not allowed by the SNMP community named in the message.

InASNParseErrs Displays the total number of ASN.1 or BER (bit error rate) errors encountered when decoding received SNMP messages.

4-14Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 79: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

SilentDrops Displays the total number of the following protocol data units (PDUs) that were delivered and were dropped silently:

• GetRequest-PDUs

• GetNextRequest-PDUs

• GetBulkRequest-PDUs

• SetRequest-PDUs

• InformRequest-PDUs

These PDUs were dropped because the size of a reply containing an alternate Response-PDU with an empty variable-bindings field was greater than either a local constraint or the maximum message size associated with the originator of the request.

ProxyDrops Displays the total number of the following PDUs that were delivered and were dropped silently:

• GetRequest-PDUs

• GetNextRequest-PDUs

• GetBulkRequest-PDUs

• SetRequest-PDUs

• InformRequest-PDUs

These PDUs were dropped because the transmission of the (possibly translated) message to a proxy target failed in a manner (other than a timeout), such that no Response-PDU could be returned.

Table 4-14 IP > Statistics > SNMP—Display-Only Attributes (continued)

Display-Only Attribute Description

4-15Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 80: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 4 Managing VSANsControlling In-Band Management Connectivity

4-16Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 81: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected] documentation

Cisco MDS 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C H A P T E R 5

Managing Administrator Access

The Cisco Fabric Manager lets you control management access to Cisco MDS 9000 Family switches, whether you are using the command-line interface (CLI) or SNMP. The Cisco Fabric Manager uses SNMP to communicate remotely with switches. This chapter describes how to set up SNMP users and roles, and how to assign different administrative privileges to different roles.

This chapter also describes how to set up a RADIUS server to provide authentication services to CLI users. To remotely access switches using the CLI, you use Telnet or SSH. For information about managing remote CLI access or configuring a local database for authenticating CLI users, refer to the Cisco 9000 Family Configuration Guide.

This chapter includes the following sections:

• Managing SNMP Users and Roles, page 5-1

• Configuring RADIUS Security for CLI Access, page 5-8

Managing SNMP Users and RolesThis section describes how to configure or view SNMPv3 users and roles, which allow you to control remote administrative access to Cisco MDS 9000 Family switches. It includes the following topics:

• Viewing SNMP Users, Roles, and Communities, page 5-1

• Configuring SNMP Communities, page 5-3

• Configuring User Roles, page 5-5

• Role Views (Advanced), page 5-7

Viewing SNMP Users, Roles, and CommunitiesSNMP v3 provides a security model for controlling management access to managed devices in the form of a set of users and roles. Users are assigned to specific roles, and specific administrative privileges are assigned to each role. User names are authenticated through passwords, which are stored and transmitted in encrypted form. In addition, SNMPv3 includes the Privacy option, which encrypts all management traffic exchanged between switches.

SNMP v1 and v2 provide a very limited authentication scheme in the form of read and write community strings. Community strings are like user names, without passwords, and are stored and sent over the SNMP network in clear text (unencrypted) form. For this reason, SNMPv3 should be used wherever network security is a concern.

5-19000 Family Fabric Manager User Guide

Page 82: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 5 Managing Administrator AccessManaging SNMP Users and Roles

To view information about SNMP users, roles, and communities from Fabric Manager, choose Security > SNMP > Users on the menu tree. To view this information from the Device Manager, choose SNMP from the Security menu. Figure 5-1 shows the SNMP dialog box from the Device Manager.

Figure 5-1 Security > SNMP Dialog Box, Device Manager

Both dialog boxes show the display-only information described in Table 5-1.

Table 5-2 describes the configurable attributes for SNMP security.

Table 5-1 Security > SNMP—Display-only Attributes

Display-Only Information Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

User Displays the name of the user with system access.

Role Displays the name of the role or group to which this user belongs. For example, nwadminGroup indicates that the user belongs to the network administration group.

Auth: Digest Displays the encryption (Hash) algorithm used to encrypt passwords.

Table 5-2 Security > SNMP—Display-only Attributes

Display-Only Information Description

Auth: Password Specifies the password used for authenticating the user.

PrivPassword Specifies the password used for encrypting management traffic.

Status Determines the status of the user’s access. Valid values are:

• active—The user has valid system access.

• NotInService—The user does not have valid system access.

• notReady—The user account is not ready.

5-2Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 83: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 5 Managing Administrator AccessManaging SNMP Users and Roles

To add a user or community string, follows these steps:

Step 1 Click Create on the Device Manager dialog box, or click the Create Row button on the Fabric Manager toolbar.

From Device Manager, you see the dialog box shown in Figure 5-2.

Figure 5-2 Create User, Device Manager

The dialog box from Fabric Manager also provides a check box to specify one or more switches.

Step 2 Enter the user name in the New User field.

Step 3 Select the role from the drop-down list.

Step 4 Enter the password for the user twice in the New Password and Confirm Password fields.

Step 5 Click the Privacy check box and complete the password fields to enable encryption of management traffic,

Enter the Authentication password in the Clone Password field to use the same password. Enter a new password twice in the New Password and Confirm Password fields.

Step 6 Click Apply to create the new entry or click OK to create the entry and close the dialog box.

Configuring SNMP CommunitiesIf you are running SNMPv3, you must define users (or security names), assign them to roles (or groups), and assign system access based on those roles. If you are running SNMPv1 or SNMPv2c, you must define communities, which are equivalent to SNMPv3 users or security names. SNMPv3 allows you to define user access to the object level. SNMPv1 and SNMPv2c do not allow you to define system access at the object level.

Table 5-3 shows the mapping of users (SNMPv3) and communities (SNMPv1 and SNMPv2c).

5-3Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 84: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 5 Managing Administrator AccessManaging SNMP Users and Roles

To configure users and communities from the Device Manager, choose SNMP from the Security menu. and click the Communities tab. To configure users and communities from the Fabric Manager, choose Security > SNMP > Communities from the menu tree. Figure 5-3 shows the SNMP dialog box with the Communities tab selected from the Device Manager.

Figure 5-3 Security > SNMP > Communities Dialog Box, Device Manager

Both dialog boxes show the display-only information described in Table 5-4.

To add a community string, follow these steps:

Step 1 Click Create on the Device Manager dialog box or click the Create Row button on the Fabric Manager toolbar.

From Device Manager, the system displays the dialog box shown in Figure 5-4.

Figure 5-4 Create Community, Device Manager

Table 5-3 SNMP Mappings

SNMPv3 SNMPv1, SNMPv2c

user or security name community

role role

Table 5-4 Security > SNMP > Communities—Display-Only Attributes

Display-Only Information Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Community Specifies the SNMPv1/SNMPv2c community name, which is equivalent to an SNMPv3 user.

Role Specifies the name of the group to which the community or user belongs.

5-4Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 85: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 5 Managing Administrator AccessManaging SNMP Users and Roles

The dialog box from Fabric Manager also provides a check box to specify one or more switches.

Step 2 Enter the community string in the Community field.

Step 3 Select the user role from the pull-down selection list.

Step 4 Click Create.

Configuring User RolesUser roles let you define a set of administrative permissions to a role and then assign this role to different users.

To configure users roles, choose SNMP from the Device Manager Security menu, and click the Roles tab. See Figure 5-5.

Figure 5-5 Security > SNMP > Roles Dialog Box, Device Manager

This dialog box shows the display-only information described in Table 5-5.

Table 5-5 Security > SNMP > Roles—Display-Only Attributes

Display-Only Information Description

Role Specifies the name of the group to which the community or user belongs.

Level Specifies access level for the selected view. Check the radio button for the appropriate level:

• authNoPriv—Authenticated with no privacy (encryption)

• authPriv—Authenticated with privacy (encryption)

5-5Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 86: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 5 Managing Administrator AccessManaging SNMP Users and Roles

To create a new role, follow these steps:

Step 1 Click Create.

The system displays the dialog box shown in Figure 5-6.

Figure 5-6 Create Role, Device Manager

ReadAccess Specifies read-only access for the selected view. Check the appropriate radio button to select views for access:

• all—Grants read-only access to all views.

• none—Denies read-only access to all views.

• list—Grants read-only access to selected views. Check the check boxes to select views for which read access is to be granted.

WriteAccess Specifies write access for the selected view. Check the appropriate radio button to select views:

• all—Grants read-only access to all views.

• none—Denies read-only access to all views.

• list—Grants read-only access to selected views. Check the check boxes to select views for which write access is to be granted.

Table 5-5 Security > SNMP > Roles—Display-Only Attributes (continued)

Display-Only Information Description

5-6Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 87: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 5 Managing Administrator AccessManaging SNMP Users and Roles

Step 2 Enter an identifier for the role in the Role field.

Step 3 Select one of the following security levels:

• authNoPrv—Authentication without encryption

• AuthPriv—Authentication with encryption

Step 4 For Read access, click the All radio button to enable full read access or click List and click each check box in the list to enable read access to specific information.

Step 5 For Write access, click the All radio button to enable full read access or click List and click each check box in the list to enable read access to specific information.

Step 6 Click Apply to create the new role or click OK to create the role and close the window.

Role Views (Advanced)To see role views from the Device Manager, choose SNMP from the Security menu, and click the Role Views (Advanced) tab.

The dialog box shows the display-only information described in Table 5-6.

Table 5-6 Security > SNMP > Role Views—Display-Only Attributes

Display-Only Information Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

ViewName, Subtree Displays the text and numeric names of the subtree of accessible views.

Type Displays the type. Valid values are:

• included—The view is accessible.

• excluded—The view is not accessible.

Mask Displays the bit mask of the subtree.

5-7Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 88: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 5 Managing Administrator AccessConfiguring RADIUS Security for CLI Access

Configuring RADIUS Security for CLI AccessThis section describes how to configure RADIUS servers for managing administrative access to the CLI. It includes the following topics:

• Configuring RADIUS Authentication, page 5-8

• Configuring RADIUS Servers, page 5-9

Configuring RADIUS AuthenticationTo configure RADIUS authentication from the Fabric Manager, choose Radius > General from the menu tree. To configure RADIUS authentication from the Device Manager, choose Radius (CLI) from the Security menu. Figure 5-7 shows the dialog box with the General tab selected from the Device Manager.

Figure 5-7 Security > Radius Dialog Box, Device Manager

Table 5-7 describes the configurable attributes for RADIUS authentication.

Table 5-7 Security > Radius

Configurable Attribute Description

Switch Displays the switch ID. This is a display-only attribute, in Fabric Manager only.

LoginAuthentication Enables RADIUS login authentication for either Telnet or console sessions.

AuthKeyType Specifies the authentication key type. Check the radio button to select either a plain text or an encrypted authentication key type.

AuthKey Specifies the authentication key to be used to encrypt packets that are passing between the RADIUS server and the client. This key must match the key configured on the server.

5-8Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 89: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 5 Managing Administrator AccessConfiguring RADIUS Security for CLI Access

Configuring RADIUS ServersTo configure RADIUS servers from the Device Manager, choose Radius from the Security menu and click the Servers tab. To configure RADIUS servers from the Fabric Manager, choose Radius > Servers from the menu tree. Figure 5-8 shows the dialog box with the Servers tab selected from the Device Manager.

Figure 5-8 Security > Radius > Servers Dialog Box, Device Manager

Table 5-8 describes the configurable attributes for RADIUS servers.

Timeout Specifies the time (in seconds) between retransmissions to the RADIUS server. Valid values are 1 to 1000 seconds.

Retransmits Specifies the number of times the authentication request should be tried before giving up on the RADIUS server. Valid values are 1 to100 retransmits.

Table 5-7 Security > Radius (continued)

Configurable Attribute Description

Table 5-8 Security > Radius > Servers—Configurable Attributes

Configurable Attribute Description

Switch Displays the switch ID. This is a display-only attribute, in Fabric Manager only.

Index Specifies the RADIUS server’s index or ID.

IpAddress Specifies the RADIUS server’s IP address.

AuthPort Specifies the destination UDP port number to which RADIUS authentication messages should be sent. Valid values are 0 to 65535. If set to 0, this RADIUS server is not used for authentication.

AcctPort Specifies the destination UDP port number to which RADIUS accounting messages should be sent. Valid values are 0 to 65535.

KeyType Specifies the authentication key type. Check the radio button to select either a plain text or an encrypted authentication key type.

5-9Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 90: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 5 Managing Administrator AccessConfiguring RADIUS Security for CLI Access

To add a Radius server, click Create on the Device Manager dialog box, or click the Create Row button on the Fabric Manager toolbar.

From Device Manager, you see the dialog box shown in Figure 5-9.

Figure 5-9 Create Radius Server, Device Manager

The dialog box from Fabric Manager lets you specify the switches to which the configuration applies

See Table 5-8 for information about each field, complete the fields, and click OK.

Key Specifies the authentication key to be used to encrypt packets that are passing between the RADIUS server and the client. This key must match the key configured on the server.

Type Specifies the RADIUS server type. Click the radio button to specify either primary or other.

Mode Specifies the RADIUS server mode. Click the radio button to select:

• authAndAcct—Selects both authentication and accounting mode.

• authOnly—Selects authentication mode only.

• acctOnly—Selects accounting mode only.

• none—Specifies no mode.

Table 5-8 Security > Radius > Servers—Configurable Attributes (continued)

Configurable Attribute Description

5-10Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 91: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected] documentation

Cisco MDS 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C H A P T E R 6

Managing Software and Configuration Files

This chapter describes how to manage software images and modules.

Note For more information about managing software image and configuration files using the command-line interface (CLI), refer to the Cisco 9000 Family Configuration Guide or the Cisco 9000 Family Command Reference.

This chapter includes the following sections:

• Overview, page 6-1

• Downloading Software Images, page 6-2

• Copying Configuration Files, page 6-3

• Saving Configurations, page 6-5

OverviewEach switch in the Cisco MDS 9000 Family is shipped with a Cisco Multilayer intelligent SAN operating system called SAN-OS and two images:

• The kickstart image—Loads the kernel and basic drivers

• The system image—Loads the system image

To upgrade to a different software version, you need to download the new image software to your local switch. To start running the new image files, use the CLI to change the relevant configuration variables to point to the new images and restart the switch. For information about the specific procedures and commands, refer to the Cisco 9000 Family Configuration Guide.

All Cisco MDS 9000 Family switches contain internal bootflash memory that resides in the supervisor module. Cisco MDS 9500 Series directors contain an additional external CompactFlash called slot0: (see Figure 6-1).

6-19000 Family Fabric Manager User Guide

Page 92: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 6 Managing Software and Configuration FilesDownloading Software Images

Figure 6-1 Flash Devices in the Cisco MDS 9000 Family

Upgrading a software image does not disrupt use of the startup configuration file, which you can still use after the upgrade. When you restart the switch, the startup configuration is converted so that it is useable by the new image.

Downloading Software ImagesTo download software images using the Fabric Manager, choose Admin > Download Software Image from the menu tree. To download software images using the Device Manager, choose Download Software Image from the Admin menu. Figure 6-2 shows the dialog box from the Device Manager.

Figure 6-2 Admin > Download Software Images Dialog Box, Device Manager

The Fabric Manager dialog box shows the display-only information described in Table 6-1.

The Device Manager dialog box shows the display-only information described in Table 6-2.

ExternalCompactFlash

7952

7

Internalbootflash

Internalbootflash

Cisco MDS 9500 Series Director

Slot 0

Cisco MDS 9216 Switch

Table 6-1 Admin > Download Software Images—Display-Only Attributes

Display-Only Information Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Status Displays the status of the software image download.

Fail Reason Displays the reason if the download operation failed.

6-2Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 93: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 6 Managing Software and Configuration FilesCopying Configuration Files

Table 6-3 describes the configurable attributes for downloading software images.

Copying Configuration Files To copy configurations from the Fabric Manager, choose Admin > Copy Configuration from the menu tree. To copy configurations from the Device Manager, choose Copy Configuration from the Admin menu. Figure 6-3 shows the dialog box from the Device Manager.

Table 6-2 Admin > Download Software Images—Display-Only Attributes

Display-Only Information Description

RunningImage The file name of the software image currently running on the switch.

BootFlashSize The size, in Megabytes, of the boot flash on the switch.

Table 6-3 Admin > Download Software Images—Configurable Attributes

Display-Only Information Description

Select In Fabric Manager, enable this check box to download a software image to a specific switch.

ServerAddress/From TFTP Server:Address Enter the IP address of the TFTP server from which you are downloading the software image.

SourceName/From TFTP Server:Filename Specifies the file name of the software image. In Device Manager, click the …button to the right of the field to select a source file.

DestinationName Specifies the name of the destination file. In Device Manager, click the arrow button to the right of the field to select either:

• bootflash:/—Copies the image to boot flash.

• slot0:/—Copies the image to slot 0.

6-3Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 94: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 6 Managing Software and Configuration FilesCopying Configuration Files

Figure 6-3 Admin > Copy Configuration Dialog Box, Device Manager

The Fabric Manager dialog box shows the display-only information described in Table 6-4.

Table 6-5 describes the configurable attributes for copying configurations.

Table 6-4 Admin > Download Software Images—Display-Only Attributes

Display-Only Information Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Status Displays the status of the copy action.

FailureCause Displays the reason if the copy action fails.

Table 6-5 Admin > Copy Configuration—Configurable Attributes

Configurable Attribute Description

From Specifies the file type of the source file. Valid values are runningConfig or startupConfig. The source file’s type must be different from the destination file’s type.

If the source file is a network file, the server address and source file name must be created. These three attributes (source file type, server address, and source file name) uniquely identify the source file.

If the source file is an IOS file, the source file name must be created. The source file type and source file name uniquely identify the source file.

To Specifies the file type of the destination file. Valid values are runningConfig or startupConfig. The destination file’s type must be different from the source file’s type.

If the destination file is a network file, the server address and destination file name must be created. These three attributes (destination file type, server address, and destination file name) uniquely identify the destination file.

If the destination file is an IOS file, the destination file name must be created. The destination file type and destination file name uniquely identify the destination file.

6-4Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 95: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 6 Managing Software and Configuration FilesSaving Configurations

Saving ConfigurationsTo save configurations from the Device Manager, choose Save Configuration from the Admin menu. You are prompted whether you wish to copy the running configuration to the startup configuration. Click Yes to save the configuration.

Address Specifies the IP address of the TFTP server from/to which the configuration file is to be copied. If either the source file type or the destination file type is a network file, the server address is required.

FileName Specifies the file name (including the path, if applicable) of the source or destination file. If either the source file type or the destination file type is an IOS file, the file name is required.

Protocol Specifies the protocol to be used for the copy operation. If a protocol is not specified, the default is TFTP.

If the copy operation occurs locally on the SNMP agent, the protocol is ignored.

UserName Specifies the remote user name for copy operations through FTP, RCP, SFTP, or SCP protocols. The remote user name is required for any of these protocols.

If the protocol is RCP, it overrides the remote user name configured through the rcmd remote-username configuration command. The remote user name is sent as the server user name in an RCP command request sent by the system to a remote RCP server.

UserPassword Specifies the password used by FTP, SFTP, or SCP protocols for copying a file to/from an FTP/SFTP/SCP server. This password is required for the FTP or SCP protocols.

Table 6-5 Admin > Copy Configuration—Configurable Attributes (continued)

Configurable Attribute Description

6-5Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 96: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 6 Managing Software and Configuration FilesSaving Configurations

6-6Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 97: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected]

Cisco MDS 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C H A P T E R 7

Managing Interfaces

Fabric Manager allows you to configure and monitor interfaces on multiple Cisco 9000 switches. The Device Manager allows you to configure and monitor interfaces on a single Cisco 9000 switch.

This chapter describes how to configure interfaces using the Fabric Manager and Device Manager. For information about interfaces and configuring them using the command-line interface (CLI), refer to the Cisco 9000 Family Configuration Guide. This chapter includes the following sections:

• Managing Ports, page 7-1

• Managing PortChannel Interfaces, page 7-12

• Monitoring Port Statistics, page 7-16

Managing PortsThis section describes how to enable, disable, configure, and view port attributes and statistics. It includes the following topics:

• Enabling or Disabling Ports, page 7-1

• Managing General Port Attributes, page 7-2

• Managing Interface Attributes for Ports, page 7-4

• Viewing FLOGI Attributes, page 7-5

• Viewing Port ELP Attributes, page 7-7

• Viewing Trunking Information, page 7-9

• Managing Physical Attributes for a Port, page 7-10

• Viewing Port Capability Attributes, page 7-11

Enabling or Disabling PortsTo enable a port, right-click on a disabled port in Device Manager and choose Enable from the pop-up menu.

To disable a port, right-click on a enabled port in Device Manager and choose Disable from the pop-up menu.

To enable or disable multiple ports, ctrl-click each port or drag the mouse around a group of ports. Then right-click any of the selected ports and click either Enable or Disable from the pop-up menu.

7-19000 Family Fabric Manager User Guide

Page 98: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging Ports

Managing General Port AttributesTo manage general port attributes, such as Alias, PortVsan, and Admin Mode from the Fabric Manager, select the Switch tab at the bottom of the screen and choose Interface from the menu tree and then choose the type of port. To manage these attributes from the Device Manager, choose the type of port from the Interface menu. You can select FxPorts, xEPorts, Enabled Ports, All Ports, or the Mgmt Port.

The following are the different port types supported by the Cisco MDS 9000 Family.

• xE ports:

– An E_Port (expansion port) connects two switches and can carry frames between switches for configuration and management of the fabric for a single VSAN.

– A TE_Port (trunking expansion port) allows a link between two Cisco 9000 switches to carry traffic for multiple VSANs.

• Fx ports:

– An F_Port (fabric port) connects to an N_Port (end node port) on a host node through a point-to-point link.

– An Fl_Port (fabric loop port) connects to an NL_Port (end node loop port) on a public loop through a point-to-point link or an arbitrated loop.

• A TL (translative loop) port may be connected to one or more private loop devices (NL ports). TL ports are unique to Cisco MDS 9000 Family switches and have similar properties to FL ports. The default is Auto, so the switch will autonegotiate the port speed.

For further information about port types, refer to the Cisco 9000 Family Configuration Guide.

The dialog boxes from the Fabric Manager display attributes for multiple switches. Figure 7-1 shows the dialog box with the General tab selected from the Device Manager, which displays general attributes for a single switch.

Figure 7-1 Interface > All Ports Dialog Box, Device Manager

The dialog boxes in both tools provide the information described in Table 7-1 (the order of the columns varies slightly between the two tools).

7-2Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 99: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging Ports

Table 7-2 describes the configurable port attributes.

Table 7-1 Interface > xxPorts > General —Display-Only Port Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Port Displays the port ID.

Mode—Oper Displays the current operating mode of the port.

Trunk—Oper Displays the current trunking mode of the port. Valid values are:

• trunk—In trunking mode

• nonTrunk—Not in trunking mode

• auto—Automatically set based on the value set on the connected port

Trunk—ActiveVsans Displays the VSANs with which this port is associated. Only ports operating in trunking mode can belong to multiple VSANs.

Speed—Oper Displays an estimate of the interface's current bandwidth, in bits per second.

Status—Oper Displays the current operating status of the interface.

Status—Cause Displays the cause of the current operating status of the interface.

Table 7-2 Interface > xxPorts > General—Configurable Port Attributes

Configurable Attribute Description

Alias Specifies an alias for the port.

PortVsan Specifes the ID of the VSAN to which this interface is statically assigned.

Mode—Admin Specifies the port’s mode. Valid values are:

• auto—Automatically set based on the value of the connected port

Note In any pair of ports, only one port can be set for autodetect.

• F—Fabric port

• FL—Fabric loop port

• E—Expansion port

• FX—Either FL or F

• SD—Span destination port

• TL—Translative loop port

7-3Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 100: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging Ports

Managing Interface Attributes for PortsTo manage port interface attributes from the Fabric Manager, choose Interface from the menu tree and then choose one of the following port types to be configured:

• Port Channels

• xEPorts

• FxPorts

• Other Ports

To manage port interface attributes from the Device Manager, choose a port type from the Interface menu.

The Fabric Manager dialog box displays interface attributes for multiple switches. The dialog box from Device Manager displays interface attributes for a single switch. Both dialog boxes provide the display-only information described in Table 7-3.

Trunk—Admin Specifies the port’s trunking mode. Valid values are:

• trunk—In trunking mode

• nonTrunk—Not in trunking mode

• auto—Automatically set based on the value of the connected port

Trunk—AllowedVsans Specifies the VSANs that are allowed to be received/ transmitted on the port when the port is operating in trunking mode. Valid values are 1 to 4093. Only ports operating in trunking mode can belong to multiple VSANs.

Speed—Admin Specifies the port speed. Valid values are:

• auto

• 1 Gb/s

• 2 Gb/s

Status—Admin Specifies the port status.

Table 7-2 Interface > xxPorts > General—Configurable Port Attributes (continued)

Configurable Attribute Description

Table 7-3 Interface > xxPorts > Interfaces—Display Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Index Displays the port ID. This attribute is only displayed from the Fabric Manager.

7-4Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 101: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging Ports

Table 7-4 describes the configurable interface attributes for ports.

Viewing FLOGI AttributesTo view fabric login (FLOGI) attributes, such as the Fibre Channel ID (FCID), port name, and class of service for FxPorts from the Fabric Manager, choose Interface > FxPorts > LoggedIn on the menu tree.

To view FLOGI attributes from the Device Manager, choose FxPorts or All Ports from the Interface menu and click the FLOGI tab.

The dialog box in Fabric Manager displays attributes for multiple switches. The dialog box from Device Manager displays attributes for a single switch. Both dialog boxes provide the display-only information described in Table 7-5.

Mtu Displays the size of the largest packet that can be sent or received on the interface, specified in octets. For interfaces that transmit network datagrams, this is the size of the largest network datagram that can be sent on the interface.

LastChange Displays the date and time the interface entered its current operating state.

PortChannelid Displays the PortChannel to which this port belongs.

Wwn Displays the 64-bit world wide name for the port.

BbCreditModel Displays the buffer-to-buffer credit model used by the port.

An alternate BbCreditModel can be used in an arbitrated loop topology to manage the flow of frames between the two ports participating in the loop circuit.

HoldTime Displays the maximum time (in milliseconds) that the port holds a frame in the transmitter buffer before discarding it, if it is unable to deliver the frame.

A zero (0) value indicates the frame is discarded immediately if the port is unable to deliver the frame.

Table 7-3 Interface > xxPorts > Interfaces—Display Only Attributes (continued)

Display-Only Attribute Description

Table 7-4 Interface > xxPorts > Interfaces—Configurable Attributes

Configurable Attribute Description

Alias Specifies the alias for the interface.

EnableLinkTrap Enables or disables traps for the link.

7-5Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 102: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging Ports

Table 7-5 Interface > FxPorts > LoggedIn—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Port Displays the logged-in Nx_Port’s port ID.

Fcid Displays the Fibre Channel ID that has been assigned to the logged-in Nx_Port.

PortName Displays the logged-in Nx_Port’s world wide name.

NodeName Displays the world wide name of the remote node to which the logged-in Nx_Port belongs.

Version Displays the version of FC-PH (Fibre Channel Physical Interface) that the logged-in Nx_Port has agreed to support from the fabric login.

BB Credit—Rx Displays the maximum number of receive buffers available for holding class 2 and class 3 frames received from the logged-in Nx_Port. This attribute is for buffer-to-buffer flow control in the incoming direction from the logged-in Nx_Port to the Fibre Channel port.

BB Credit—Tx Displays the total number of buffers available for holding class 2 and class 3 frames to be transmitted to the logged-in Nx_Port. This attribute is for buffer-to-buffer flow control in the direction from the Fibre Channel port to the logged-in Nx_Port.

CoS Displays the classes of service for which the logged-in Nx_Port has requested support from the Fibre Channel port.

Class 2—RxDataSize Displays the class 2 receive data field size of the logged-in Nx_Port. This attribute specifies the largest data field size for an FT_1 frame that can be received by the Nx_Port.

Class 2—SeqDeliv Displays whether the port has agreed to support class 2 sequential delivery during the fabric login. This is meaningful only if class 2 service has been agreed upon. This attribute is applicable only to Fx_Ports.

7-6Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 103: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging Ports

Viewing Port ELP AttributesTo monitor exchange link parameter (ELP) attributes, such as port and node world wide names and class of service from the Fabric Manager, choose Interface > xEPorts > ELP from the menu tree. To monitor these attributes from the Device Manager, choose xEPorts or All Ports from the Interface menu and click the ELP tab.

The dialog box in Fabric Manager displays attributes for multiple switches. The dialog box from Device Manager displays attributes for a single switch. Both dialog boxes provide the display-only information described in Table 7-6.

Class 3—RxDataSize Displays the class 3 receive data field size of the logged-in Nx_Port. This attribute specifies the largest data field size for an FT_1 frame that can be received by the Nx_Port.

Class 3—SeqDeliv Displays whether the FxPort has agreed to support class 3 sequential delivery during the fabric login. This is meaningful only if class 3 service has been agreed upon. This attribute is applicable only to Fx_Ports.

Table 7-5 Interface > FxPorts > LoggedIn—Display-Only Attributes (continued)

Display-Only Attribute Description

Table 7-6 Interface > xEPorts > ELP —Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Port Displays the port ID.

NbrPortNodeName (Fabric Manager)NeighborWWNs—Port (Device Manager)

Displays the node world wide name of the peer (neighbor) node.

NbrPortName (Fabric Manager)NeighborWWNs—Node (Device Manager)

Displays the port world wide name of the peer (neighbor) Interconnect_Port.

BbCredit—Rx Displays the maximum number of receive buffers available for holding class 2, class 3, and class F frames received from the peer Interconnect_Port. This attribute provides buffer-to-buffer flow control in the incoming direction from the peer Interconnect_Port to the local Interconnect_Port.

BbCredit—Tx Displays the total number of buffers available for holding class 2,class 3, and class F frames to be transmitted to the peer Interconnect_Port. This attribute provides buffer-to-buffer flow control in the direction from the local Interconnect_Port to peer Interconnect_Port.

7-7Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 104: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging Ports

CoS Displays the classes of services for which the peer Interconnect_Port has requested support from the local Interconnect_Port, and the local Interconnect_Port has granted the request.

Class 2—SeqDeliv Displays whether the local Interconnect_Port has agreed to support class 2 sequential delivery during the ELP switch fabric internal link service request. This is meaningful only if class 2 service has been agreed upon.

Class 2 —RxDataSize Displays the class 2 receive data field size of the peer Interconnect_Port. This attribute specifies the largest data field size for an FT_1 frame that can be received by the Interconnect_Port.This is meaningful only if class 2 service has been agreed upon.

Class 3—SeqDeliv Displays whether the local Interconnect_Port has agreed to support class 3 sequential delivery during the ELP switch fabric internal link service request. This is meaningful only if class 3 service has been agreed upon.

Class 3 RxDataSize Displays the class 3 receive data field size of the peer Interconnect_Port. This attribute specifies the largest data field size for an FT_1 frame that can be received by the Interconnect_Port.This is meaningful only if class 3 service has been agreed upon.

XII Indicates, when true, that the peer Interconnect_Port supplying this attribute requires that an interlock be used during X_id assignment in class F. This is meaningful only if class F service has been agreed upon.

Class F—RxDataSize Displays the class F receive data field size of the peer Interconnect_Port. class F service is always agreed upon between two Interconnect_Ports. This attribute specifies the largest data field size for an FT_1 frame that can be received by the Interconnect_Port.

Class F—ConSeq Displays the number of sequence status blocks provided by the Interconnect_Port for tracking the progress of a sequence as a sequence recipient. The maximum number of concurrent sequences that can be specified is 255.

Table 7-6 Interface > xEPorts > ELP —Display-Only Attributes (continued)

Display-Only Attribute Description

7-8Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 105: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging Ports

Viewing Trunking InformationTo monitor trunking for ports from the Fabric Manager, choose Interface > xEPorts > Trunk Status from the menu tree. To view trunking for ports from the Device Manager, choose xEPorts from the Interface menu and then click the Trunk Status tab.

The dialog box in Fabric Manager displays attributes for multiple switches. The dialog box from Device Manager displays attributes for a single switch. Both dialog boxes provide the display-only information described in Table 7-7.

Class F—EECredit Displays the maximum number of class F data frames that can be transmitted by an Interconnect_Port without receipt of accompanying ACK or link_response frames. The minimum value of end-to-end credit is one. The end-to-end credit field specified is associated with the number of buffers available for holding the data field of a class F frame and processing the contents of that data field by the Interconnect_Port supplying the attributes.

Class F—OpenSeq Displays the maximum number of sequences that can be open at one time at the recipient between a pair of Interconnect_Ports for one exchange.This value is used for exchange and sequence tracking.

Table 7-6 Interface > xEPorts > ELP —Display-Only Attributes (continued)

Display-Only Attribute Description

Table 7-7 Interface > xEPorts > Trunk Status—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Port, Vsan Displays the port ID and the VSAN ID.

OperStatus Displays the current operating state of the port. Valid values are up, down, and disabled.

If the port is in trunking mode, it is possible for the port state to be down only in some VSANs.

OperStatusCause Displays the cause of the port’s current operating state.

7-9Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 106: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging Ports

Managing Physical Attributes for a PortTo configure beacon mode and monitor physical attributes for ports from the Fabric Manager, choose Interface from the menu tree and choose the type of port to be configured:

• Port Channels

• xEPorts

• FxPorts

• Other Ports

To configure beacon mode and monitor physical attributes for ports from the Device Manager, choose the type of port from the Interface menu and click the Physical tab.

The dialog box in Fabric Manager displays attributes for multiple switches. The dialog box from Device Manager displays attributes for a single switch. Both dialog boxes provide the display-only information described in Table 7-8.

To enable or disable beacon mode, check the BeaconMode check box. When beacon mode is enabled, an interface LED flashes to identify the interface.

Table 7-8 Interface > FxPorts > Physical—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Index (Fabric Manager)

ID (Device Manager)

Displays the port ID.

ConnectorPresent Displays whether the interface has a physical connector. Valid values are true and false.

This attribute is only displayed from the Device Manager.

TransmitterType Displays the technology type of the port.

ConnectorType Displays the module type of the port connector. Valid values are:

• embedded—The gigabit interface converter (GBIC) hardware is not removable.

• gbicSerialid—Displays if the GBIC serial ID can be read, otherwise it displays gbicNoSerialid.

• sfpSerialid—Displays if the GBIC’s serial ID can be read, otherwise it displays sfpNoSerialid.

SerialNo Displays the serial number of the GBIC.

Revision Displays the port revision of the GBIC.

Vendor Displays the name of the GBIC manufacturer.

7-10Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 107: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging Ports

Viewing Port Capability AttributesTo monitor port capability attributes, such as buffer-to-buffer credit, hold time, and class of service from the Fabric Manager, choose Interface from the menu tree and choose the type of port to be configured:

• xEPorts

• FxPorts

• Disabled Ports

To monitor these attributes from the Device Manager, choose the type of port from the Interface menu and click the Capability tab.

The dialog box in Fabric Manager displays attributes for multiple switches. The dialog box from Device Manager displays attributes for a single switch. Both dialog boxes provide the display-only information described in Table 7-9.

.Table 7-9 Interface > FxPorts > Capabilities—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Port Displays the port ID.

FcphVersion—Low Displays the lowest version of FC-PH that the port is capable of supporting.

FcphVersion—High Displays the highest version of FC-PH that the port is capable of supporting.

BbCredit—Min Displays the minimum number of receive buffers the port hardware (ASIC) is capable of holding for class 2 or class 3 frames from the attached Nx_Port.

Displays, for xE_ports, the maximum number of receive buffers the port hardware (ASIC) is capable of holding for class F frames from the attached xE_port.

BbCredit—Max Displays the maximum number of receive buffers the port hardware (ASIC) is capable of holding for class 2 or class 3 frames from the attached Nx_Port.

Displays, for xE_ports, the maximum number of receive buffers the port hardware (ASIC) is capable of holding for class F frames from the attached xE_port.

RxDataSize—Min Displays the minimum size of the data field (in bytes) in a frame that the port is capable of receiving from its attached port.

RxDataSize—Max Displays the maximum size of the data field (in bytes) in a frame that the port is capable of receiving from its attached port.

7-11Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 108: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging PortChannel Interfaces

Managing PortChannel InterfacesPortChanneling, also called port bundling, is the aggregation of multiple physical ports into one logical port to provide higher bandwidth, load balancing, and link redundancy. The Fabric Manager allows you to configure and monitor PortChannel interfaces on multiple Cisco 9000 switches. The Device Manager allows you to configure and monitor PortChannel interfaces on a single Cisco 9000 switch. This section describes how to configure PortChannel interfaces using the Fabric Manager and the Device Manager and includes the following topics:

• Managing PortChannel General Attributes, page 7-12

• Managing PortChannel Interface Attributes, page 7-14

Managing PortChannel General AttributesTo manage PortChannels from the Fabric Manager, choose Interface > PortChannels > General from the menu tree. To manage PortChannels from the Device View, choose PortChannels from the Interface menu.

The dialog box in Fabric Manager displays attributes for multiple switches. The dialog box from Device Manager (Figure 7-2) displays attributes for a single switch.

Figure 7-2 PortChannels

Both dialog boxes show the display-only information described in Table 7-10.

HoldTime—Min Displays the minimum holding time (in microseconds) that the port is capable of supporting.

HoldTime—Max Displays the maximum holding time (in microseconds) that the port is capable of supporting.

Cos Displays the bit mask indicating the set of classes of service that the port is capable of supporting.

Class2SeqDeliv Displays whether the port is capable of supporting class 2 sequential delivery.

Class3SeqDeliv Displays whether the port is capable of supporting class 3 sequential delivery.

Table 7-9 Interface > FxPorts > Capabilities—Display-Only Attributes (continued)

Display-Only Attribute Description

7-12Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 109: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging PortChannel Interfaces

Table 7-11 describes the configurable PortChannel general attributes.

To add ports to a PortChannel, click Create. You see the dialog box shown in Figure 7-3.

Table 7-10 Interface > PortChannels > General—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

OperMode Displays the port’s current operating channel mode.

LastAction—Status Displays the status of the last operation (add or remove a member) performed. Valid values are successful and failed.

LastAction—Cause Displays the cause of failure to add ports to a PortChannel. This attribute displays zero (0) if the last operation was successful.

LastAction—Time Displays the time the last action was performed on this PortChannel.

CreationTime Displays the time the PortChannel was created.

Table 7-11 Interface > PortChannels > General—Configurable Attributes

Configurable Attributes Description

Membership: Check Specifies the method to be adopted by the agent to add ports to a PortChannel. Valid values are:

• normal—A compatibility check is done on the parameters of the ports being added to the PortChannel. The ports being added must have the same physical and configured parameters as the PortChannel.

• force—A compatibility check is done only on physical parameters. The ports being added must have the same physical parameters as the PortChannel. The ports’ configured parameters are overwritten by the PortChannel’s configured parameters.

Membership:List/MemberList Specifies the xEPorts that are members of this PortChannel.

7-13Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 110: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging PortChannel Interfaces

Figure 7-3 Create PortChannels

Click the button to the right of the MemberList field and select any members to include in the PortChannel. Identify the other options you want to use and click OK.

Managing PortChannel Interface AttributesTo manage PortChannel interface attributes, such as the port mode and trunking from the Fabric Manager, choose the Interfaces > PortChannels > Interfaces from the menu tree. To manage PortChannel interface attributes from the Device Manager, choose PortChannels from the Interface menu and click the Interfaces tab.

The dialog box in Fabric Manager displays attributes for multiple switches. The dialog box from Device Manager displays attributes for a single switch. Both dialog boxes provide the display-only information described in Table 7-12.

Table 7-12 Interface > PortChannels > Interfaces—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Group Displays the PortChannel’s interface ID.

Mode—Oper Displays the current operating channel mode of the port.

Trunk—Oper Displays the current operating state of the trunk. Valid values are up, down, and disabled.

Trunk—ActiveVsans Displays the VSANs this port is associated with. Only ports operating in trunking mode can belong to multiple VSANs.

Speed Displays an estimate of the port’s current bandwidth in bits per second.

• For interfaces with a bandwidth that does not vary or where there is no accurate estimation of bandwidth, a nominal bandwidth displays.

• If the interface’s bandwidth is greater than the maximum bandwidth reportable, the maximum bandwidth value displays.

Status—Oper Displays the current operating state of the port. Valid values are up, down, and disabled.

7-14Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 111: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesManaging PortChannel Interfaces

Table 7-13 describes the configurable PortChannel interface attributes.

Status—Cause Displays the cause of the port’s current operating state.

LastChange Displays the date and time the interface entered its current operating state.

Table 7-12 Interface > PortChannels > Interfaces—Display-Only Attributes (continued)

Display-Only Attribute Description

Table 7-13 Interface > PortChannels > Interfaces—Configurable Attributes

Configurable Attributes Description

Alias Specifies the PortChannel’s alias.

PortVsan Specifies the ID of the VSAN to which this interface is statically assigned.

Mode—Admin Specifies the current operating mode of the port. Valid values are:

• auto—Autonegotiated based on the value configured on the connected port

• F—Fabric port

• FL—Fabric loop port

• E—Expansion port

• FX—Either F or FL

• SD—SPAN destination port

• TL—Translative loop port

Trunk—Admin Specifies the desired state of the trunk. Valid values are:

• trunk—In trunking mode

• nonTrunk—Not in trunking mode

• auto—Autonegotiated based on the value configured on the connected port

Trunk—AllowedVsans Specifies the VSANs that are allowed to be received or transmitted on the port when the port is operating in trunking mode. Only ports operating in trunking mode can belong to multiple VSANs.

Status—Admin Specifies the desired state of the interface. Valid values are:

• up

• down—When a managed system initializes, all interfaces start in the down state.

• testing—No operational packets can be passed.

7-15Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 112: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesMonitoring Port Statistics

Monitoring Port StatisticsThis section describes how to monitor port statistics, the options available, and the different types of statistics you can monitor. These options are available on the Interface menu from Device Manager’s Device View or Summary View. This section includes the following topics:

• Monitoring and Charting Traffic Statistics, page 7-16

• Monitoring Port Traffic (Bytes), page 7-17

• Monitoring Port Traffic (Frames), page 7-18

• Monitoring Port Discards, page 7-18

• Monitoring Port Class 2 Errors, page 7-19

• Monitoring Port Link Errors, page 7-19

• Monitoring Port Sequence Errors, page 7-20

• Monitoring Port Frame Errors, page 7-21

Monitoring and Charting Traffic StatisticsTo monitor port traffic, discards, and errors for ports from the Device Manager, choose Monitor Selected from the Interface menu or right-click on one or more ports and choose Monitor from the pop-up menu. You see the dialog box shown in Figure 7-4.

Figure 7-4 Monitoring Ports

You can change the display by changing the following attributes from the Monitor Selected dialog box:

• Interval—Specifies the polling interval for the display in seconds, minutes, hours.

• AbsoluteValue—The actual counter value for the interface.

• Cumulative—The difference between the original absolute value and the last value retrieved for the interface.

• Average/sec —The average last value since the category was first displayed.

• Minimum/sec—The smallest last value.

7-16Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 113: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesMonitoring Port Statistics

• Maximum/sec—The largest last value.

• LastValue/sec—The difference between the current and previous counter values, normalized to per/second.

To display a line, area, or bar chart graph, select a traffic statistic and click one of the chart icons on the left side of the dialog box. You see the dialog box shown in Figure 7-5.

Figure 7-5 Bar Chart

Monitoring Port Traffic (Bytes)To monitor port traffic bytes from the Device view, choose the Port Traffic (Bytes) tab from the Port Monitor dialog box. The dialog box shows the display-only information described in Table 7-14.

Table 7-14 Interface > Monitor Selected > Traffic (Bytes)—Display-Only Attributes

Display-Only Attribute Description

Port Displays the port ID.

Class2 Rx Displays the class 2 bytes received by the port.

Class2 Tx Displays the class 2 bytes transmitted by the port.

Class3 Rx Displays the class 3 bytes received by the port.

Class3 Tx Displays the class 3 bytes transmitted by the port.

ClassF Rx Displays the class F bytes received by the port.

ClassF Tx Displays the class F bytes transmitted by the port.

Total Bytes Rx Displays the total bytes received by the port.

Total Bytes Tx Displays the total bytes transmitted by the port.

7-17Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 114: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesMonitoring Port Statistics

Monitoring Port Traffic (Frames)To monitor port traffic frames, choose the Port Traffic (Frames) tab on the Monitor Selected dialog box. The dialog box shows the display-only information described in Table 7-15.

Monitoring Port DiscardsTo monitor port discards, click the Discards tab on the Monitor Selected dialog box. The dialog box shows the display-only information described in Table 7-16.

Table 7-15 Interface > Monitor Selected > Traffic (Frames)—Display-Only Attributes

Display-Only Attribute Description

Port Displays the port ID.

Class2 Rx Displays the class 2 frames received by the port.

Class2 Tx Displays the class 2 frames transmitted by the port.

Class3 Rx Displays the class 3 frames received by the port.

Class3 Tx Displays the class 3 frames transmitted by the port.

ClassF Rx Displays the class F frames received by the port.

ClassF Tx Displays the class F frames transmitted by the port.

Total Bytes Rx Displays the total frames received by the port.

Total Bytes Tx Displays the total frames transmitted by the port.

Table 7-16 Interface > Monitor Selected > Discards—Display-Only Attributes

Display-Only Attribute Description

Port Displays the port ID.

Frames Displays the number of frames discarded by the port.

EISL Displays the number of Extended Inter-Switch Link (EISL) frames discarded by the port.

Class 2 Displays the number of class 2 frames discarded by the port.

Class 3 Displays the number of class 3 frames discarded by the port.

Class F Displays the number of class F frames discarded by the port.

7-18Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 115: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesMonitoring Port Statistics

Monitoring Port Class 2 ErrorsTo monitor port class 2 errors, click the Class 2 Errors tab on the Monitor Selected dialog box. The dialog box shows the display-only information described in Table 7-17.

Monitoring Port Link ErrorsTo monitor port link errors, click the Link Errors tab on the Monitor Selected dialog box. The dialog box shows the display-only information described in Table 7-18.

TotalRx Displays the total number of inbound packets that were discarded even though no errors had been detected to prevent them being delivered to a higher layer protocol. One possible reason for discarding such a packet would be to free up buffer space.

TotalTx Displays the total number of outbound packets that were discarded even though no errors had been detected to prevent them being delivered to a higher layer protocol. One possible reason for discarding such a packet would be to free up buffer space.

Table 7-16 Interface > Monitor Selected > Discards—Display-Only Attributes (continued)

Display-Only Attribute Description

Table 7-17 Interface > Monitor Selected > Class 2 Errors—Display-Only Attributes

Display-Only Attribute Description

Port Displays the port ID.

FBSY Displays the number of F_Port-busy frames generated by this port against class 2 frames.

FRJT Displays the number of F_Port-reject frames generated by this port against class 2 frames.

PBSY Displays the number of times that port busy was returned to this port when a class 2 frame could not be delivered to the other end of the link. This occurs if the destination Nx_Port is temporarily busy.

PRJT Displays the number of times that port reject was returned to this port when a class 3 frame was rejected at the destination Nx_Port.

7-19Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 116: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesMonitoring Port Statistics

Monitoring Port Sequence ErrorsTo monitor port sequence errors, click the Seq Errors tab on the Monitor Selected dialog box. The dialog box shows the display-only information described in Table 7-19.

Table 7-18 Interface > Monitor Selected > Link Errors—Display-Only Attributes

Display-Only Attribute Description

Port Displays the port ID.

LinkFailures Displays the number of link failures detected by the port.

SigLosses Displays the number of signal losses detected by the port.

SyncLosses Displays the number of loss-of-synchronization failures detected by the port.

InvalidTxWords Displays the number of invalid transmission words detected by the port.

BBCreditTransitionFromZero Displays the number of buffer-to-buffer credit transitions out of zero state.

TxWaitCount Displays the number of times the port waited due to lack of transmit credits.

LinkResetIns Displays the number of link reset protocol errors received by the port from the attached port.

LinkResetOuts Displays the number of link reset protocol errors transmitted by the port from the attached port.

LRRIn Displays the number of link reset responses received by the port.

LRROut Displays the number of link reset responses transmitted by the port.

Table 7-19 Interface > Monitor Selected > Seq Errors—Display-Only Attributes

Display-Only Attributes Description

Port Displays the port ID.

PrimSeqProtoErrors Displays the number of primitive sequence protocol errors detected by the port.

DelimiterErrors Displays the number of delimiter errors detected by the port.

UnknownClassFrames Displays the number of unknown class frames received by the port.

EOFaFrames Displays the number of frames with EOF aborts received by the port.

AddressidErrors Displays the number of address identifier errors detected by the port.

7-20Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 117: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesMonitoring Port Statistics

Monitoring Port Frame ErrorsTo monitor port frame errors, click the Frame Errors tab on the Monitor Selected dialog box. The dialog box shows the display-only information described in Table 7-20.

OlsIns Displays the number of offline sequence errors received by the port.

OlsOuts Displays the number of offline sequence errors issued by the port.

NOSIn Displays the number of nonoperational sequences received by the port.

NOSOut Displays the number of nonoperational sequences transmitted by the port.

Table 7-19 Interface > Monitor Selected > Seq Errors—Display-Only Attributes (continued)

Display-Only Attributes Description

Table 7-20 Interface > Monitor Selected > Frame Errors—Display-Only Attributes

Display-Only Attributes Description

Port Displays the port ID.

InvalidCrcs Displays the number of invalid CRCs detected by the port. Loop ports should not count CRC errors passing through when monitoring.

FragFrames Displays the number of fragmented frames received by the port.

RuntFramesIn Displays the number of frames received by the port that are shorter than the minimum allowable frame length, whether the CRC is good or not.

JabberFramesIn Displays the number of frames received by the port that are longer than a maximum frame length, and also have a CRC error.

FramesTooLong Displays the number of frames received by the port where the frame length was greater than what was agreed to in FLOGI/PLOGI. This could be caused by losing the end-of-frame delimiter.

FramesTooShort Displays the number of frames received by the port where the frame length was less than the minimum indicated by the frame header. Normally the frame-length minimum is 24 bytes, but it could be more if the DFCTL field indicates an optional header should be present.

FramingErrorFrames Displays the number of framing errors.

ELPFailures Displays the number of ELP switch fabric internal link service request failures detected by the port. This attribute is applicable only to interconnect ports, which are E_Ports or B_Ports.

7-21Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 118: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 7 Managing InterfacesMonitoring Port Statistics

Managing PortChannelsTo create a PortChannel from Fabric Manager, right-click two or more Inter-Switch Links (ISLs) and select PortChannel from the pop-up menu. You see the dialog box shown in Figure 7-6.

Figure 7-6 Create PortChannel Dialog Box

To add a link to an existing PortChannel, right-click an ISL on the Fabric Manager map and select PortChannel from the pop-up menu. You see the confirmation prompt shown in Figure 7-7.

Figure 7-7 Add to Port Channel Confirmation Prompt

Click Add to add a link to a PortChannel when the ports on each link and at both ends of the link have the same port speed, trunking type, and administrative state.

To force the addition of the link to a PortChannel, regardless of the port attributes, click the ForceAdd button.

Note To create a PortChannel, all the ports on both ends of the link must have the same port speed, trunking type, and administrative state.

7-22Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 119: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected] documentation

Cisco MDS 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C H A P T E R 8

Managing Events and Alarms

By configuring how events are reported, you can monitor those events more effectively and take corrective action, if necessary. Cisco Fabric Manager provides the following features for reporting and responding to network events:

• SNMP events—These are preconfigured notifications, including SNMPv2 traps and SNMPv3 informs.

• RMON alarms—These are configurable notifications that you can set based on thresholds for various network events.

• Call Home—This is a feature that lets you configure automatically generated e-mail messages or other responses to specific events.

• Syslog—This is a standard message log that records various network and system events.

Note The Fabric Manager allows you to manage events on multiple Cisco MDS 9000 Family switches. The Device Manager allows you to manage events on a single Cisco MDS 9000 Family switch.

This chapter describes how to configure events using the Fabric Manager and Device Manager. For information about events and configuring them using the command-line interface (CLI), refer to the Cisco 9000 Family Configuration Guide.

This chapter includes the following sections:

• Managing Events, page 8-1

• Enabling RMON Alarms, page 8-7

• Managing RMON Alarms and Events, page 8-10

• Configuring the Call Home Feature, page 8-17

• Configuring the Syslog, page 8-23

Managing EventsThis section describes how to manage events and includes the following topics:

• Viewing the Events Log, page 8-2

• Configuring Event Destinations, page 8-3

• Configuring Event Security, page 8-5

• Configuring Event Filters, page 8-6

8-19000 Family Fabric Manager User Guide

Page 120: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging Events

Viewing the Events LogTo view the events log from the Device Manager, choose SNMP Log from the Events menu. The Events Log dialog box displays a log of events for a single switch and shows the display-only information described in Table 8-1.

To manage the SNMP log, choose SNMP Log from the Events menu and click the Controls tab. The Controls tab provides summary statistics about the SNMP log and allows you to change the default settings for the log.

The dialog box shows the display-only information described in Table 8-2.

Table 8-3 describes the configurable attributes for the SNMP log.

Caution Changing these values from different Fabric Manager workstations at the same time may cause unpredictable results.

Table 8-1 Events > SNMP Log —Display-Only Attributes

Display-Only Attribute Description

DateAndTime Displays the local date and time the event was logged.

Type Displays the type of notification that occurred.

Details Displays the details of the event that was logged.

Table 8-2 Events > SNMP Log —Display-Only Attributes

Display-Only Attribute Description

NotificationsLogged The number of log entries. The same event written to multiple logs is counted multiple times.

NotifcationsBumped The number of log entries discarded to make room for a new entry due to lack of resources or reaching the maximum log size. This does not include entries discarded due to the value set for the AgeOut attribute.

Table 8-3 Events > SNMP Log —Display-Only Attributes

Display-Only Attribute Description

EntryLimit The maximum number of notification entries stored in the log. A value of 0 means no limit.

AgeOut The number of minutes an event is kept in a log before it is automatically removed. A value of 0 means entries are not aged out.

8-2Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 121: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging Events

Configuring Event DestinationsCisco MDS 9000 Family switches, like other SNMP-enabled devices, send events (traps and informs) to configurable destinations, called trap receivers in SNMPv2. To configure event destinations from the Fabric Manager, choose Events > Destinations on the menu tree. To configure event destinations from the Device Manager, choose Destinations from the Events menu.

The dialog box from the Fabric Manager displays event destination information for multiple switches. Figure 8-1 shows the dialog box with the Addresses tab selected from the Device Manager. This dialog box displays event destinations for a single switch.

Figure 8-1 Events > Destinations Dialog Box, Device Manager

Both dialog boxes show the display-only information described in Table 8-4.

Table 8-5 describes the configurable attributes for event destinations.

Table 8-4 Events > Destinations—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch name or IP address. This attribute is only displayed from the Fabric Manager.

Security Displays the security.

Types Displays the type of notification to be generated for an event (traps for v2c or informs for v3).

Table 8-5 Events > Destinations—Configurable Attributes

Configurable Attribute Description

Address/Port Specifies the IP address and port of the event destination.

Security Identifies the version of SNMP, such as v2c for version 2c, or v3 for version 3.

Types Identifies the type of events (traps for v2c or informs for v3).

8-3Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 122: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging Events

To create an event destination, click Create on the Device Manager dialog box or click the Create Row button on the Fabric Manager toolbar.

From Device Manager, you see the dialog box shown in Figure 8-2.

Figure 8-2 Create Destinations Dialog Box, Device Manager

The dialog box from the Fabric Manager lets you select a switch.

Timeout Specifies the amount of time an application must wait for a response.

Note The timeout value can be based on a particular retransmission algorithm and on the number of timeouts that have occurred. Consider the type of message when configuring the timeout value. For example, if a message has a security level that requires both authentication and privacy, you should increase the timeout value to compensate for the extra processing time needed for the authentication and encryption processing.

RetryCount Specifies the default number of retries to be attempted when a response is not received for a generated message. If an application provides its own retry count, the value of this attribute is ignored.

Status Specifies the row status. Valid values are:

• active

• notInService

• notReady

• createAndGo

• createAndWait

• destroy

Table 8-5 Events > Destinations—Configurable Attributes (continued)

Configurable Attribute Description

8-4Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 123: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging Events

The Timeout option lets you specify the length of time in 1/100 seconds that the system should wait to make a connection. The Retry Count option lets you specify how many times the system should retry.

See Table 8-4 for information about the other fields on this dialog box.

Complete the fields and click Apply to create the event destination or click OK to create the destination and close the window.

Configuring Event Security

Caution This is an advanced function that should only be used by administrators having experience with SNMPv3.

To configure event security from the Fabric Manager, choose Events > Security on the menu tree. To configure event security from the Device Manager, choose Destinations from the Events menu and click the Security tab.

The dialog box from the Fabric Manager displays event security information for multiple switches. The dialog box from Device Manager displays event security for a single switch.

Both dialog boxes show the display-only information described in Table 8-6.

Table 8-7 describes the configurable security attributes for event destinations.

Table 8-6 Events > Security—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Name Displays the principal on whose behalf the SNMP messages are generated.

Table 8-7 Event Destinations Security—Configurable Attributes

Configurable Attribute Description

MPModel Specifies the message processing model to be used when generating SNMP messages.

SecurityModel Specifies the security model to be used when generating SNMP messages.

8-5Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 124: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging Events

Configuring Event FiltersTo configure event filters from the Fabric Manager, choose Events > FC Filters or Other Filters on the menu tree. To configure event filters from the Device Manager, choose Filters from the Events menu.

Figure 8-3 shows the Event Filters dialog box from the Device Manager, which displays event filters for a single switch. Fabric Manager displays two different dialog boxes, which list the same event filters for multiple switches, in different order.

Figure 8-3 Event Filters Dialog Box

To configure event filters, check the check box next to the appropriate filter name. The event filters are described in Table 8-8.

SecurityName Specifies the community string (v1, v2) or user name (v3) on whose behalf SNMP messages are generated.

SecurityLevel Specifies the level of security to be used when generating SNMP messages. Valid values are:

• NoAuthNoPriv—No authorization with no privacy (encryption)

• authNoPriv—Authorization with no privacy (encryption)

• authPriv—Authorization with privacy (encryption)

Table 8-7 Event Destinations Security—Configurable Attributes (continued)

Configurable Attribute Description

8-6Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 125: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsEnabling RMON Alarms

Enabling RMON AlarmsThis section describes how to define and enable preconfigured RMON alarms and includes the following topics:

• Enabling RMON Alarms by Port, page 8-8

• Enabling RMON Alarms for VSANs, page 8-9

• Enabling RMON Alarms for Physical Components, page 8-10

The “Managing RMON Alarms and Events” section on page 8-10 provides information about changing the default controls for RMON alarms, viewing the alarm events that have been defined, defining custom event severity levels, and viewing the event log.

Table 8-8 Event Filters

Event Filter Description

FSPF - Nbr State Changes Issues a notification when the local switch learns of a change in the neighbor's state on an interface on a VSAN.

Domain Mgr - ReConfig Fabrics Issues a notification when sending or receiving a ReConfigureFabric request on a VSAN.

Zone Server - Request Rejects Issues a notification when a zone server request is rejected.

Zone Server - Merge Failures Issues a notification when a zone merge fails.

Zone Server - Merge Successes Issues a notification when a zone merge occurs.

Zone Server - Default Zone Behavior Change Issues a notification when default zone behavior is changed (exclusive or inclusive).

FabricConfigServer - Request Rejects Issues a notification when a fabric configuration server request is rejected.

RSCN - ILS Request Rejects Issues a notification when an RSCN ILS request is rejected.

RSCN - ELS Request Rejects Issues a notification when an RSCN ELS request is rejected.

SNMP - Bad Logins Enables or disables generation of an SNMP authenticationFailure trap.

Note We recommend that you save this attribute in nonvolatile memory so that it remains constant across reinitializations of the network management system.

VRRP Specifies whether a VRRP-enabled router can generate SNMP traps.

8-7Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 126: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsEnabling RMON Alarms

Enabling RMON Alarms by PortTo enable alarm notifications by port from the Device Manager, choose Threshold Manager from the Events menu and click the Ports tab. (See Figure 8-4.)

Figure 8-4 RMON Threshold Manager, Ports Tab

To configure an RMON alarm for one or more ports, follow these steps:

Step 1 Select the ports to monitor.

a. Click the Selected radio button.

b. Click the button to the right of the Selected field to display all ports.

c. Select the ports you want to monitor.

Alternatively, click the appropriate radio button to select ports by type:

• All ports

• xE ports

• Fx ports

Step 2 Click the check box for each variable that you want to monitor.

Step 3 Enter the threshold value in the Value column.

Step 4 Enter the sampling period in seconds.

8-8Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 127: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsEnabling RMON Alarms

Step 5 Select one of the following severity levels to assign to the alarm:

• Fatal

• Warning

• Critical

• Error

• Information

Step 6 Click Create.

Step 7 Confirm the operation to define an alarm and a log event when the system prompts you to define a severity event.

If you do not confirm the operation, the system only defines a log event.

Enabling RMON Alarms for VSANsTo manage RMON alarm service attributes for selected VSANs from the Device Manager, choose Threshold Manager from the Events menu and click the Services tab. Figure 8-5 shows the Threshold Manager dialog box with the Services tab selected.

Figure 8-5 Threshold Manager, Services Tab

To enable an RMON alarm for one or more VSANs, follow these steps:

Step 1 Enter one or more VSANs to monitor in the VSAN Id(s) field.

Step 2 Click the check box for each variable that you want to monitor.

Step 3 Enter the threshold value in the Value column.

Step 4 Enter the sampling period in seconds.

Step 5 Select a severity level to assign to the alarm:

Step 6 Click Create.

Step 7 Confirm the operation to define an alarm and a log event when the system prompts you to define a severity event.

8-9Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 128: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging RMON Alarms and Events

If you do not confirm the operation, the system only defines a log event.

Enabling RMON Alarms for Physical ComponentsTo configure RMON alarm physical attributes from the Device Manager, choose Threshold Manager from the Events menu and click the Physical tab. Figure 8-6 shows the Create RMON Alarms dialog box with the Physical tab selected.

Figure 8-6 Threshold Manager, Physical Tab

To configure an RMON alarm for a physical component, follow these steps:

Step 1 Click the check box for each variable that you want to monitor.

Step 2 Enter the threshold value in the Value column.

Step 3 Enter the sampling period in seconds.

Step 4 Select one of the following severity levels to assign to the alarm:

• Fatal

• Warning

• Critical

• Error

• Information

Step 5 Click Create.

Step 6 Confirm the operation to define an alarm and a log event when the system prompts you to define a severity event.

If you do not confirm the operation, the system only defines a log event.

Managing RMON Alarms and EventsThis section describes changing the default controls for RMON alarms, viewing the alarm events that have been defined, defining custom event severity levels, and viewing the event log. It includes the following topics:

• Configuring RMON Controls, page 8-11

• Managing RMON Alarms, page 8-11

8-10Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 129: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging RMON Alarms and Events

• Managing RMON Event Severity Levels, page 8-15

• Viewing the RMON Log, page 8-16

Configuring RMON ControlsTo change the default controls for RMON alarms, choose Threshold Manager from the Device Manager menu. You see the Threshold Manager window shown earlier in Figure 8-4.

Click More on the Threshold Manager window. You see the dialog box shown in Figure 8-7.

Figure 8-7 RMON Thresholds Controls Dialog Box

Table 8-9 describes the configurable attributes for RMON controls.

Managing RMON AlarmsTo view the alarms that have already been enabled, choose Threshold Manager from the Events menu and click the More button on the Threshold Manager dialog box. Then click the Alarms tab. You see the dialog box shown in Figure 8-8.

Table 8-9 RMON Alarms > Controls—Configurable Attributes

Configurable Attribute Description

AlarmEnable Enables or disables the RMON alarm feature on this device.

MaxAlarms Specifies the maximum number of entries allowed in the alarmTable.

8-11Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 130: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging RMON Alarms and Events

Figure 8-8 RMON Thresholds—Alarms Tab

To create a customized threshold entry, click the Create button. You see the dialog box shown in Figure 8-9.

Figure 8-9 Create RMON Thresholds Alarms

The dialog boxes show the display-only information described in Table 8-10.

8-12Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 131: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging RMON Alarms and Events

Table 8-11 describes the configurable attributes for RMON alarm thresholds.

Table 8-10 Events > RMON Alarms—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Falling—Threshold Displays a threshold for the sampled statistic. When the sampled value falls equal to or below this threshold, an event is generated.

Falling—Event Displays the ID of the event that is generated when the sampled value falls equal to or below this threshold.

Table 8-11 Events > RMON Alarms—Configurable Attributes

Configurable Attribute Description

Index Specifies the ID of the RMON alarm. Valid values are 1 to 65535. By default, the index values from 1 through 5 are assigned to predefined event severity levels, as follows:

• 1—Fatal

• 2—Critical

• 3—Error

• 4—Warning

• 5—Information

Interval Specifies the time interval, in seconds, over which the data is sampled and compared with the rising and falling thresholds. Valid values are 1 to 3600 seconds.

Variable Specifies the variable to be sampled.

SampleType Specifies the method of sampling the selected variable and calculating the value to be compared against the thresholds. Valid values are:

• absoluteValue—The value of the selected variable is compared directly with the thresholds at the end of the sampling interval.

• deltaValue— The value of the selected variable at the last sample is subtracted from the current value, and the difference is compared with the thresholds.

8-13Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 132: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging RMON Alarms and Events

StartupAlarm Specifies the alarm that is sent when a threshold is exceeded. Valid values are:

• risingAlarm—A single rising alarm is generated.

• fallingAlarm—A single falling alarm is generated.

• risingOrFallingAlarm—Either a rising or a falling alarm is generated.

RisingTheshold Specifies the threshold for the sampled statistic.

When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event is generated.

A single event is also generated if the first sample is greater than or equal to this threshold and the StartupAlarm is either a risingAlarm or a risingOrFallingAlarm.

After a rising event is generated, another rising event is not generated until the sampled value falls below this threshold and reaches the FallingThreshold.

RisingEventIndex Specifies the ID of the event that is generated when a rising threshold is crossed. Valid values are 0 to 65535, where 0 indicates that no event is to be generated.

Owner Specifies the person who configured the RMON alarm thresholds.

Table 8-11 Events > RMON Alarms—Configurable Attributes (continued)

Configurable Attribute Description

8-14Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 133: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging RMON Alarms and Events

Managing RMON Event Severity LevelsTo define customized RMON event severity levels, select Threshold Manager from the Events menu and click More on the Threshold Manager dialog box. Then click the Events tab on the RMON Thresholds dialog box. You see the dialog box shown in Figure 8-10.

Figure 8-10 RMON Thresholds Events Tab

To create a new threshold entry, click the Create button. You see the dialog box shown in Figure 8-11.

Figure 8-11 Create RMON Thresholds Events

Table 8-12 describes the attributes for RMON event thresholds.

Table 8-12 RMON Alarms > Events—Configurable Attributes

Configurable Attribute Description

Index Specifies the event severity level identifier. By default, the index values from 1 through 5 are assigned to predefined event severity levels, as follows:

• 1—Fatal

• 2—Critical

• 3—Error

• 4—Warning

• 5—Information

Description Provides a description of this event severity level.

8-15Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 134: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsManaging RMON Alarms and Events

Viewing the RMON LogTo view the RMON log from the Device Manager, select Threshold Manager from the Events menu and click More on the Threshold Manager dialog box. Then click the Log tab on the RMON Thresholds dialog box. You see the dialog box shown in Figure 8-12.

Figure 8-12 Events > RMON Alarms > Logs Dialog Box, Fabric Manager

The RMON Log dialog box shows the display-only information described in Table 8-13.

Type Specifies the type of response to the event. Valid values are:

• none—No event is generated.

• log—An entry is made in the log table for each event.

• snmptrap—An SNMP trap is sent to one or more management stations.

• logandtrap—An entry is made in the log table and an SNMP trap is sent for each event.

Community Specifies the SNMP community to authenticate the SNMP trap.

Owner Specifies the person who configured the RMON alarm thresholds.

Table 8-12 RMON Alarms > Events—Configurable Attributes (continued)

Configurable Attribute Description

Table 8-13 RMON Log—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

EventId, Id Displays the event ID.

Time Displays the time this log entry was created.

Description Describes the event that triggered this log entry.

8-16Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 135: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Call Home Feature

Configuring the Call Home FeatureThis section describes how to configure the Call Home feature, which automatically sends e-mail notifications in response to configurable events. This section includes the following topics:

• Overview of Features, page 8-17

• Configuration Overview, page 8-17

• Configuring Call Home Attributes, page 8-18

• Configuring Call Home Destination Attributes, page 8-19

• Configuring Call Home E-Mail Addresses, page 8-21

• Configuring Call Home Alerts, page 8-21

• Configuring Call Home Profiles, page 8-22

Overview of FeaturesYou can use Call Home for direct paging of a network support engineer, E-mail notification to a Network Operations Center, and utilization of Cisco AutoNotify services for direct case generation with the Technical Assistance Center. Call Home provides the following features:

• Fixed set of predefined alerts and trigger events on the switch.

• Automatic execution and attachment of relevant command output.

• Multiple message format options:

– Short Text — Suitable for pagers or printed reports.

– Plain Text — Full formatted message information suitable for human reading.

– XML — Matching readable format using Extensible Markup Language (XML) and Document Type Definitions (DTDs) named Messaging Markup Language (MML). The MML DTD is published on the Cisco Connection Online (CCO) website at http://www.cisco.com/. The XML format enables communication with the Cisco Systems TAC group.

• Multiple concurrent message destinations. Up to 50 e-mail destination addresses are allowed for each format type.

• Message categories include system, environment, switching module hardware, services module hardware, supervisor module, hardware, inventory, and test.

Configuration OverviewWhen configuring Call Home, keep the following points in mind:

• You must configure at least one E-mail server and at least one destination profile. The destination profile(s) used depends on whether the notification is sent to a pager, email, or automated service such as Cisco AutoNotify.

• You must configure the contact name (SNMP server contact), phone, and street address information before enabling Call Home.

• The Cisco MDS 9000 switch must have IP connectivity to an E-mail server.

• To use Cisco AutoNotify you must obtain an active service contract for the device.

8-17Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 136: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Call Home Feature

To configure Call Home, use the different tabs on the Call Home dialog box, as summarized below:

Step 1 Assign contact information and enable the Call Home feature using the General tab (see the “Configuring Call Home Attributes” section on page 8-18). The Call Home feature is not enabled by default, and you must enter an e-mail address that identifies the source of Call Home notifications.

Step 2 Configure the destination e-mail addresses for Call Home notifications using the Destinations tab (see the “Configuring Call Home Destination Attributes” section on page 8-19). You can identify one more more e-mail addresses that will receive Call Home notifications.

Step 3 Identify your SMTP server using the E-mail Setup tab (see the “Configuring Call Home E-Mail Addresses” section on page 8-21). You need to identify a message server to which your switch has access. This message server will forward the Call Home notifcations to the destinations.

Step 4 Test Call Home by sending a test message using the Alerts tab (see the “Configuring Call Home Alerts” section on page 8-21). You should test the Call Home feature to make sure it works.

Configuring Call Home AttributesTo assign contact information and enable the Call Home feature from the Fabric Manager, choose Events > Call Home > General on the menu tree. To assign contact information and enable the Call Home feature from the Device Manager, choose Call Home from the Events menu and click the General tab.

Figure 8-13 shows the dialog box with the General tab selected from the Device Manager. This view displays Call Home attributes for a single switch. The dialog box from the Fabric Manager displays Call Home information for multiple switches.

Figure 8-13 Events > Call Home Dialog Box, Device Manager

Both dialog boxes provide the display-only information described in Table 8-14.

Table 8-14 describes the attributes for the Call Home feature.

8-18Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 137: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Call Home Feature

Configuring Call Home Destination AttributesTo configure the destination e-mail addresses for Call Home notifications, choose Events > Call Home > Destinations on the menu tree. To configure the destination e-mail addresses from the Device Manager, choose Call Home from the Events menu and click the Destination tab.

The dialog box from the Fabric Manager displays Call Home information for multiple switches. Figure 8-14 shows the dialog box with the Destinations tab selected from the Device Manager. This view displays Call Home attributes for a single switch.

Table 8-14 Events > Call Home—Configurable Attributes

Configurable Attribute Description

Switch Displays the switch ID. This is a display-only attribute in Fabric Manager only.

Contact Specifies the identity of the person to be notified.

PhoneNumber Specifies the phone number of the person to be notified when an alert occurs.

EmailAddress Specifies the e-mail address of the person to be notified when an alert occurs.

StreetAddress Specifies the street address of the person to be notified when an alert occurs.

CustomerId Specifies the customer ID of the person to be notified when an alert occurs.

ContractId Specifies the contract between the customer and the support partner.

SiteId Specifies the site ID of the device on which an alert has occurred.

DeviceServicePriority Specifies the service priority for the device. Valid values are:

• Emergency

• Alert

• Critical

• Error

• Warning

• Notification

• Information

• Debug

Enable Enables Call Home alerts.

8-19Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 138: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Call Home Feature

Figure 8-14 Events > Call Home > Destination Dialog Box, Device Manager

Table 8-15 describes the Destinations attributes for the Call Home feature.

To create a new Call Home destination, follow these steps:

Step 1 Click Create on the Device Manager dialog box, or click the Create Row button on the Fabric Manager toolbar.

From the Device Manager, you see the dialog box shown in Figure 8-15.

Figure 8-15 Create Call Home Destination

From the Fabric Manager, you can select one or more switches to which the configuration applies.

Step 2 Select the profile name from the pull-down list.

Step 3 Enter a number identifier for the destination.

Step 4 Enter the e-mail address for the destination.

Step 5 Click Create.

Table 8-15 Events > Call Home > Destination—Configurable Attributes

Configurable Attribute Description

ProfileName, Id Displays the profile name and ID assigned to the destination.

EmailAddress Displays the e-mail address of the destination.

8-20Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 139: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Call Home Feature

Configuring Call Home E-Mail AddressesTo identify your SMTP server from the Fabric Manager, choose Events > Call Home > Email Setup on the menu tree. To identify your SMTP server from the Device Manager, choose Call Home from the Events menu and click the Email Setup tab.

The dialog box from the Fabric Manager displays Call Home information for multiple switches. Figure 8-16 shows the dialog box with the EmailAddresses tab selected from the Device Manager. This view displays Call Home attributes for a single switch.

Figure 8-16 Events > Call Home > Email Setup Dialog Box, Device Manager

Table 8-16 describes the configurable e-mail setup attributes for the Call Home feature.

Configuring Call Home AlertsTo test Call Homefrom the Fabric Manager, choose Events > Call Home > Alerts on the menu tree. To test Call Home from the Device Manager, choose Call Home from the Events menu and click the Alerts tab.

The dialog box from the Fabric Manager displays Call Home information for multiple switches. Figure 8-17 shows the dialog box with the Alerts tab selected from the Device Manager. This view displays Call Home attributes for a single switch.

Table 8-16 Events > Call Home > Destination—Configurable Attributes

Configurable Attribute Description

From Specifies the e-mail address to be used in the From field when sending the e-mail message using SMTP.

ReplyTo Specifies the e-mail address to be used in the To field when sending the e-mail message using SMTP.

SMTP Server: Address Specifies the address of the SMTP server.

SMTP Server: Port Specifies the port of the SMTP server.

8-21Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 140: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Call Home Feature

Figure 8-17 Events > Call Home > Alerts Dialog Box, Device Manager

Both dialog boxes show the display-only information described in Table 8-17.

Table 8-18 describes the configurable alert attributes for the Call Home feature.

Configuring Call Home ProfilesTo configure Call Home attributes from the Fabric Manager, choose Events > Call Home > Profiles on the menu tree. To configure Call Home attributes from the Device Manager, choose Call Home from the Events menu and click the Profiles tab.

The dialog box from the Fabric Manager displays Call Home information for multiple switches. Figure 8-18 shows the dialog box with the Alerts tab selected from the Device Manager. This view displays Call Home attributes for a single switch.

Table 8-17 Events > Call Home > Alerts—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Status Displays the status of the alert.

LastTimeSent Displays the date and time the last alert was sent.

Number Sent Displays the number of alerts sent.

Table 8-18 Events > Call Home > Alerts—Configurable Attributes

Configurable Attribute Description

Test Specifies the type of test:

• test

• test&inventory

8-22Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 141: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Syslog

Figure 8-18 Events > Call Home > Profiles Dialog Box, Device Manager

Both dialog boxes show the display-only information described in Table 8-19.

Table 8-20 describes the configurable profile attributes for the Call Home feature.

Configuring the SyslogThis section describes how to configure the syslog and includes the following topics:

• Configuring Syslog Attributes, page 8-24

• Configuring Syslog Servers, page 8-25

• Configuring Syslog Priorities, page 8-27

Table 8-19 Call Home > Profiles—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Profile Displays the profile of the Call Home message to be sent when an alert occurs. Valid values are:

• xml

• full_txt

• short_txt

MsgFormat Displays the format of the Call Home message to be sent when an alert occurs. Valid values are:

• mml

• fullText

• shortText

Table 8-20 Call Home > Profiles—Configurable Attributes

Configurable Attribute Description

MaxMsgSize Specifies the maximum size of the Call Home message.

8-23Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 142: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Syslog

Configuring Syslog AttributesTo configure syslog attributes from the Fabric Manager, choose Events > Syslog > General on the menu tree. To configure syslog attributes from the Device Manager, choose Syslog from the Events menu and click the General tab.

The dialog box from the Fabric Manager displays syslog information for multiple switches. Figure 8-19 shows the Syslog dialog box with the General tab selected from the Device Manager. This view displays syslog information for a single switch.

Figure 8-19 Events > Syslog > General Dialog Box, Device Manager

The Fabric View dialog box shows the display-only information described in Table 8-21.

Table 8-22 describes the configurable general attributes for the syslog.

Table 8-21 Events > Syslog > General—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

8-24Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 143: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Syslog

Configuring Syslog ServersTo configure syslog attributes from the Fabric Manager, choose Events > Syslog > Servers on the menu tree. To configure syslog servers from the Device Manager, choose Syslog from the Events menu and click the Servers tab.

The dialog box from the Fabric Manager displays syslog information for multiple switches. Figure 8-20 shows the Syslog dialog box with the Servers tab selected from the Device Manager. This view displays syslog information for a single switch.

Table 8-22 Events > Syslog > General—Configurable Attributes

Configurable Attribute Description

ConsoleEnable Enables syslog messages at the console.

ConsoleMsgSeverity Specifies the minimum severity of the messages sent to the console. Valid values are:

• Emergency

• Alert

• Critical

• Error

• Warning

• Notification

• Information

• Debug

LogFileName Specifies the name of the log file to which syslog messages are sent.

LogFileMsgSeverity Specifies the minimum severity of the messages sent to the log file. Valid values are:

• Emergency

• Alert

• Critical

• Error

• Warning

• Notification

• Information

• Debug

8-25Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 144: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Syslog

Figure 8-20 Events > Syslog > Servers Dialog Box, Device Manager

Both dialog boxes show the display-only information described in Table 8-23.

Table 8-24 describes the configurable server attributes for the syslog.

To add a syslog server, click Create. You see the dialog box shown in Figure 8-21.

Table 8-23 Events > Syslog > Servers—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Table 8-24 Events > Syslog > Servers—Configurable Attributes

Configurable Attribute Description

Index Specifies the server ID.

IpAddress Specifies the IP address of the server.

MsgSeverity Specifies the minimum severity of the messages sent to the server. Valid values are:

• Emergency

• Alert

• Critical

• Error

• Warning

• Notification

• Information

• Debug

8-26Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 145: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Syslog

Figure 8-21 Create Syslog Servers

Complete the fields on this dialog box and click OK.

Configuring Syslog PrioritiesTo configure syslog priorities from the Device Manager, choose Syslog from the Events menu and click the Priorities tab. To configure syslog attributes from the Fabric Manager, choose Events > Syslog > Priorities on the menu tree.

Figure 8-22 shows the Syslog dialog box with the Servers tab selected from the Device Manager. This view displays syslog information for a single switch. The dialog box from the Fabric Manager displays syslog information for multiple switches.

8-27Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 146: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Syslog

Figure 8-22 Events > Syslog > Priorities Dialog Box, Device Manager

Both dialog boxes show the display-only information described in Table 8-25.

Table 8-26 describes the configurable priorities for the syslog.

Table 8-25 Events > Syslog > Priorities—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Facility Displays the system log message facility.

8-28Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 147: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Syslog

Table 8-26 Events > Syslog > Priorities—Configurable Attributes

Configurable Attribute Description

Severity Specifies the minimum severity of the messages sent to the syslog. Valid values are:

• Emergency

• Alert

• Critical

• Error

• Warning

• Notification

• Information

• Debug

8-29Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 148: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 8 Managing Events and AlarmsConfiguring the Syslog

8-30Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 149: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected] documentation

Cisco MDS 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C H A P T E R 9

Managing the System and Components

The Fabric Manager allows you to configure and monitor modules on multiple Cisco 9000 switches. The Device Manager allows you to configure and monitor modules on a single Cisco 9000 switch.

Note For information about configuring the chassis and its components using the command-line interface (CLI), refer to the Cisco 9000 Family Configuration Guide.

This chapter describes how to configure the chassis and its components using the Fabric Manager and Device Manager.

This chapter includes the following sections:

• Managing the Switch System, page 9-1

• Managing Inventory Information, page 9-4

• Viewing Redundancy Information, page 9-5

• Managing Card Attributes, page 9-6

• Managing Temperature Sensor Information, page 9-7

• Managing Power Supplies, page 9-7

Managing the Switch SystemThis section describes how to obtain general information about a switch system. It includes the following topics:

• Viewing System Attributes, page 9-1

• Viewing Running Processes, page 9-3

• Viewing Flash File Information, page 9-4

Viewing System AttributesTo manage system attributes from the Fabric Manager, choose Physical > System > Descr on the menu tree. To manage system attributes from the Device Manager, choose System from the Admin menu. The Fabric Manager dialog box displays system attributes for multiple switches. The dialog box from the Device Manager (Figure 9-1) displays system attributes for a single switch.

9-19000 Family Fabric Manager User Guide

Page 150: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 9 Managing the System and ComponentsManaging the Switch System

Figure 9-1 System Dialog Box

Both dialog boxes show the display-only information described in Table 9-1.

Table 9-2 describes the configurable system attributes for the chassis.

Table 9-1 Physical > System—Display-Only Attributes

Display-Only Attribute Description

Descr Displays a text description of the switch, which includes the switch model and software release version.

Uptime Displays (in hundredths of a second) the date and time since the network management portion of the switch was last reinitialized.

Name Displays the unique world wide name (WWN) of this fabric element.

Location

Contact

SwitchWWN

Table 9-2 Physical > System—Configurable Attributes

Configurable Attribute Description

Name Specifies the name assigned to this node, usually the node’s fully qualified domain name.

Location Specifies the physical location of this node, for example, “telephone closet, 3rd floor.”

Contact Specifies the e-mail address of the person responsible for this node.

9-2Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 151: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 9 Managing the System and ComponentsManaging the Switch System

Viewing Running ProcessesTo view information about the processes currently running on a switch, choose Running Processes from the Admin menu. You see the dialog box shown in Figure 9-2.

Figure 9-2 Running Processes

This dialog box shows the display-only attributes described in Table 9-3.

Table 9-3 Running Processes—Display-Only Attributes

Display-Only Attribute Description

ProcessId A unique numeric identifier assigned to each process by the system when the process is started.

Name The name of the application that generated the process.

MemAllocated The number of bytes allocated by the system for the process.

CPU Time (us) The amount of CPU time used by the process.

Priority The priority of the process.

9-3Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 152: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 9 Managing the System and ComponentsManaging Inventory Information

Viewing Flash File InformationTo view information about the files currently stored in flash memory on the switch, choose Flash Files from the Admin menu. You see the dialog box shown in Figure 9-3.

Figure 9-3 Flash Files

This dialog box shows the display-only attributes described in Table 9-4.

Managing Inventory InformationTo manage inventory attributes from the Fabric Manager, choose Physical > Inventory on the menu tree. To manage inventory attributes from the Device Manager, choose Inventory from the Physical menu.

The Fabric Manager dialog box displays system attributes for multiple switches. The dialog box from the Device Manager displays system attributes for a single switch. Both dialog boxes show the display-only information described in Table 9-5.

Table 9-4 Flash Files—Display-Only Attributes

Display-Only Attribute Description

Name The file name stored in flash memory.

Size The amount of bytes used by the file in flash memory.

Table 9-5 Physical > Inventory—Read-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Name Displays the name of the chassis.

SerialNum Displays the serial number of the chassis.

MfgName Displays the name of the chassis manufacturer.

ModelName Displays the vendor-specified model name of the chassis.

9-4Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 153: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 9 Managing the System and ComponentsViewing Redundancy Information

Table 9-6 describes the configurable inventory attributes for the card.

Viewing Redundancy InformationTo monitor redundancy from the Fabric Manager, choose Physical > Redundancy on the menu tree. To monitor redundancy from the Device Manager, choose Redundancy from the Physical menu.

The Fabric Manager dialog box displays information for multiple switches. The dialog box from the Device Manager displays attributes for a single switch. Both dialog boxes show the display-only information described in Table 9-7.

HardwareRev Displays the vendor-specified hardware revision for the card.

FirmwareRev Displays the vendor-specified firmware revision for the card.

SoftwareRev Displays the vendor-specified software revision for the card.

Table 9-5 Physical > Inventory—Read-Only Attributes (continued)

Display-Only Attribute Description

Table 9-6 Physical > Inventory—Configurable Attributes

Configurable Attribute Description

Alias Specifies the alias of the module.

AssetID Specifies the asset-tracking ID of the module.

Table 9-7 Physical > Redundancy—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

SlotID Displays the slot number of the redundant module.

UnitState Displays the operational state of the redundant module.

PeerSlotId Displays the identifier of the connected (redundant) module.

PeerUnitState Displays the operational state of the connected (redundant) module.

DuplexMode Displays if duplex mode is enabled (True) or not (False).

ManualSwactInhibit Displays if the ManualSwactInhibit attribute is enabled (True) or not (False).

9-5Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 154: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 9 Managing the System and ComponentsManaging Card Attributes

Managing Card AttributesTo manage card status attributes from the Fabric Manager, choose Physical > Cards on the menu tree. To manage card status attributes from the Device Manager, choose Cards from the Physical menu.

The dialog box from the Fabric Manager displays card attributes for multiple switches. The dialog box from the Device Manager view displays attributes for a single switch. Both dialog boxes show the display-only information described in Table 9-8.

Table 9-9 describes the configurable status attributes for the card.

Table 9-8 Physical > Cards —Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Card Displays the card ID.

Module—Oper Displays the card’s current operating state.

Module—ResetReason Displays the reason for the last card reset.

Module—StatusLastChangeTime Displays the time of the last status change.

Power—Oper Displays the operating state of the card’s power.

Power—Current Displays the current supplied by the card (positive value) or current required to operate the card (negative value).

Table 9-9 Physical > Cards —Configurable Attributes

Configurable Attribute Description

Module—Admin Enables or disables the card administratively. Valid values are:

• enabled—Enables the card.

• disabled—Disables the card.

• reset—Resets the card.

• outOfServiceAdmin—Puts the card out of service.

Power—Admin Enables or disables the card’s power administratively. Valid values are:

• on—The card’s power is on.

• off—The card’s power is off.

• inlineAuto

• inlineOn

9-6Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 155: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 9 Managing the System and ComponentsManaging Temperature Sensor Information

Managing Temperature Sensor InformationTo monitor sensor temperature attributes from the Fabric Manager, choose Physical > Temperature Sensors on the menu tree. To monitor sensor attributes from the Device Manager, choose Temperature Sensors from the Physical menu.

The dialog box from the Fabric Manager displays sensor temperature attributes for multiple switches. The Sensors dialog box from the Device Manager displays sensor temperature attributes for a single switch. Both dialog boxes show the display-only information described inTable 9-10.

Table 9-11 shows the configurable sensor attributes.

Managing Power SuppliesTo manage power supply power attributes from the Fabric Manager, choose Physical > Power Supplies on the menu tree. To manage power supply power attributes from the Device Manager, choose Power Supplies from the Physical menu.

Table 9-10 Physical > Sensors —Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Name Displays a text description of the sensor that identifies the manufacturer's name, and version or model of the sensor.

Status Displays the current operational status of the sensor.

Temp. (Celsius): Value Displays the current temperature (in Celsius) reported by the sensor.

Temp. (Celsius): Threshold Displays the temperature threshold for the sensor.

Exceeded Displays the relation between the sensor value and the threshold value, required to trigger the alarm.

Severity Displays the severity of this threshold.

LastChecked Displays the time elapsed since the sensor was last checked.

UpdateRate(s) Displays the rate at which the sensor reports the temperature.

Table 9-11 Physical > Sensors —Configurable Attributes

Configurable Attribute Description

EnableNotification Displays the result of the most recent evaluation of the threshold. To enable notification when a threshold has been exceeded, check the NotificationEnable check box.

9-7Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 156: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 9 Managing the System and ComponentsManaging Power Supplies

The dialog box from the Fabric Manager displays power supply power attributes for multiple switches. The dialog box from the Device Manager displays power supply power attributes for a single switch. Both dialog boxes show the display-only information described in Table 9-12.

Table 9-12 Physical > Power Supplies—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

OperStatus Displays the current operating state of the power supply.

Units Displays the units of primary supply. For example, one 1000W power supply could deliver 100A at 10 VDC. In this case, the value of Units would be 10 VDC.

Current Displays the current supplied by the power supply (in positive values) or the current required to operate the power supply (in negative values).

TotalAvailableCurrent Displays the total current available for power supply usage.

• When the PowerRedundancyMode is set to redundant, the total current available is that available from the lesser of the two power supplies.

• When the PowerRedundancyMode is set to combined, the total current available is the sum of the capacity of all operating power supplies.

TotalDrawnCurrent Displays the total current drawn by powered-on power supplies.

9-8Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 157: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 9 Managing the System and ComponentsManaging Power Supplies

Table 9-13 describes the configurable power attributes for the power supply.

Table 9-13 Physical > Power Supplies—Configurable Attributes

Configurable Attribute Description

AdminStatus Specifies the desired state of the power supply. Valid values are:

• on—The power supply is administratively up.

• off—The power supply is administratively down.

• inlineAuto

• inlineOn

RedundancyMode Specifies the redundancy mode. Valid values are:

• notsupported—The power supplies are not redundant.

• redundant—The power supplies are redundant.

• combined

9-9Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 158: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 9 Managing the System and ComponentsManaging Power Supplies

9-10Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 159: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected] documentation

Cisco MDS 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C H A P T E R 10

Managing Fibre Channel Routing and FSPF

Fabric Shortest Path First (FSPF) is the standard path selection process used by Fibre Channel fabrics. FSPF automatically calculates the best path between any two switches in the fabric. All routes across the fabric are established when switches are powered up. These routes do not change unless there is a failure or unless a new ISL (or EISL) is created that offers a path equal to or better than an existing path.

The Fabric Manager allows you to configure and monitor these routing services on multiple Cisco 9000 switches. The Device Manager allows you to configure and monitor Fibre Channel routing and FSPF on a single Cisco 9000 switch. This chapter describes how to configure Fibre Channel routing and FSPF using the Fabric Manager and Device Manager. For information about Fibre Channel routing and how to configure routing and FSPF using the command line interface (CLI), refer to the Cisco 9000 Family Configuration Guide. This chapter includes the following information:

• Configuring Fibre Channel Routing, page 10-1

• Configuring FSPF, page 10-5

Configuring Fibre Channel RoutingThis section describes how to configure Fibre Channel routing and includes the following topics:

• Configuring Fibre Channel Routes, page 10-1

• Configuring Fibre Channel Route Flows, page 10-3

Configuring Fibre Channel RoutesTo configure Fibre Channel routes from the Device Manager, choose Routes from the FC menu. The dialog box displays routes for a single switch. Figure 10-1 shows the dialog box.

10-19000 Family Fabric Manager User Guide

Page 160: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 10 Managing Fibre Channel Routing and FSPFConfiguring Fibre Channel Routing

Figure 10-1 FC > Routes Dialog Box

The dialog box shows the display-only information described in Table 10-1.

Table 10-2 describes the configurable attributes for the route.

Table 10-1 FC > Routes—Display-Only Attributes

Display-Only Attribute Description

Vsan, Dest, Mask, Proto, Interface Displays the VSAN ID, destination Fibre Channel address ID, and the mask for the destination Fibre Channel address ID.

Table 10-2 FC > Routes—Configurable Attributes

Configurable Attribute Description

Interface Specifies the local interface through which the next hop of this route should be reached. Only Fibre Channel interfaces and PortChannel interfaces are supported.

DomainId Specifies the domain ID of next hop switch.

Metric Specifies the routing metric for this route. This attribute is not relevant for multicast route entries.

Type Specifies the type of route. Valid values are:

• direct—A route for which the next hop is the final destination.

• remote—A route for which the next hop is not the final destination.

This attribute is not relevent for multicast route entries.

Permanent Click to select or deselect whether the route is to be removed from the forwarding information base (FIB) if the port is operationally down.

This attribute is not relevent for multicast route entries.

10-2Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 161: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 10 Managing Fibre Channel Routing and FSPFConfiguring Fibre Channel Routing

To add a route from Device Manager, click Create on the dialog box. You see the dialog box shown in Figure 10-2.

Figure 10-2 Create FC Route

Click the button to the right of the Interface field and select the interface on which to configure the Fibre Channel route. Complete the other fields on this window and click OK to add a route.

Configuring Fibre Channel Route FlowsTo view Fibre Channel flows from the Fabric Manager, choose FC > Route Flow Statistics on the menu tree. To manage Fibre Channel route flows from the Device View, choose Routes from the FC menu and click the Flow Statistics tab.

The dialog box from Fabric Manager displays flows for multiple switches. The dialog box from the Device Manager displays flows for a single switch.

Figure 10-3 shows the dialog box from Device Manager.

Figure 10-3 FC > Route Flows Dialog Box

Both dialog boxes show the display-only information described in Table 10-3.

Table 10-3 The FC > Routes > Flows—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Card, Index Displays the card ID.

CreationTime Displays the time the row was created or modified.

10-3Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 162: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 10 Managing Fibre Channel Routing and FSPFConfiguring Fibre Channel Routing

Table 10-4 describes the configurable flow attributes for the route.

Table 10-4 FC > Routes > Flows—Configurable Attributes

Configurable Attribute Description

Type Specifies the flow type being used to set up the ingress traffic counters. Valid values are:

• aggregated—The VSAN ID is required when creating an entry. The following attributes are ignored (even if they are provided):

– DestId

– SrcId

– Mask (if not provided, the default value 0xffffff is used)

– Port

• exact—The following attributes are required when creating an entry:

– VsanId

– DestId

– SrcId

– Port

– Mask (optional)

This attribute cannot be modified while the corresponding value of fcRouteFlowRowStatus is equal to active.

VsanId Specifies the VSAN ID.

This attribute cannot be modified while the corresponding value of fcRouteFlowRowStatus is equal to active.

DestId Specifies the destination Fibre Channel address ID.

This attribute cannot be modified while the corresponding value of fcRouteFlowRowStatus is equal to active.

SrcId Specifies the source Fibre Channel address ID.

This attribute cannot be modified while the corresponding value of fcRouteFlowRowStatus is equal to active.

Mask Specifies the mask for source and destination Fibre Channel address ID.

This attribute cannot be modified while the flow is active.

10-4Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 163: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 10 Managing Fibre Channel Routing and FSPFConfiguring FSPF

To add a route flow from Fabric Manager, click Create Row on the toolbar. To add a route flow from Device Manager, click Create on the dialog box. You see the dialog box shown in Figure 10-4.

Figure 10-4 Insert Route Flow

Complete the fields on this window and click Create to add a route flow.

Configuring FSPFThis section describes how to configure FSPF and includes the following topics:

• Managing FSPF General Attributes, page 10-6

• Configuring FSPF Interfaces, page 10-7

• Viewing FSPF Statistics, page 10-8

• Viewing FSPF Interface Statistics, page 10-9

• Viewing Link State Records, page 10-10

• Viewing FSPF Links, page 10-11

Port Specifies the physical ingress port to which this counter applies.

This attribute cannot be modified while the flow is active.

Frames Specifies the number of received frames for the flow.

Bytes Specifies the number of received frame bytes for the flow.

Table 10-4 FC > Routes > Flows—Configurable Attributes (continued)

Configurable Attribute Description

10-5Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 164: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 10 Managing Fibre Channel Routing and FSPFConfiguring FSPF

Managing FSPF General AttributesTo manage FSPF general attributes from the Fabric Manager, choose FC > FSPF > General on the menu tree. To manage FSPF general attributes from the Device Manager, choose FSPF from the FC menu and click the General tab.

The dialog box from the Fabric Manager displays information for multiple switches. The dialog box from the Device Manager displays FSPF information for a single switch.

Figure 10-5 shows the dialog box from Device Manager.

Figure 10-5 FC > FSPF > General Dialog Box

Both dialog boxes show the display-only information described in Table 10-5.

Table 10-5 FC > FSPF > General—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan Displays the VSAN ID.

Status—Oper Displays the operational state of FSPF on this VSAN. Valid values are up and down.

DomainId Displays the domain ID of the local switch on this VSAN.

SpfComputation—Delay Displays the time between when FSPF receives topology updates and when it starts the Shortest Path First (SPF) computation on this VSAN.

Displays a smaller value if routing reacts to the changes faster, but CPU usage is greater.

LinkStateRecord—MinArrival Displays the minimum time between accepting a link state record (LSR) on this VSAN and accepting another update of the same LSR on the same VSAN.

An LSR update that is not accepted because of this time interval is discarded.

LinkStateRecord—MinInterval Displays the minimum time after this switch sends an LSR on this VSAN before it sends another update of the same LSR on the same VSAN.

10-6Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 165: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 10 Managing Fibre Channel Routing and FSPFConfiguring FSPF

Table 10-6 describes the configurable FSPF general attributes.

Configuring FSPF InterfacesTo configure FSPF interfaces from the Fabric Manager, choose FC > FSPF > Interfaces on the menu tree. To configure FSPF interfaces from the Device Manager, choose FSPF from the FC menu and click the Interfaces tab.

Both dialog boxes show the display-only information described in Table 10-7.

LinkStateRecord—RefreshTime Displays the time interval between refreshes of link state records (LSRs) on this VSAN.

LinkStateRecord—MaxAge Displays the maximum time an LSR is retained in the FSPF database on this VSAN. The LSR is removed from the database after the MaxAge is reached.

CreateTime Displays the time this entry was last created.

Table 10-5 FC > FSPF > General—Display-Only Attributes (continued)

Display-Only Attribute Description

Table 10-6 FC > FSPF > General—Configurable Attributes

Configurable Attribute Description

Status—Admin Enables or disables FSPF on this VSAN. Valid values are up and down.

RegionId Specifies the autonomous region of the local switch on this VSAN.

SpfComputation—HoldTime Specifies the minimum time between two consecutive SPF computations on this VSAN.

The smaller value indicates that routing reacts to the changes faster, but CPU usage is greater.

Table 10-7 FC > FSPF > Interfaces—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan, Port Displays the VSAN ID and port ID.

Neighbors—State Displays the state of the FSPF neighbor interface that is connected to this interface.

Neighbors—DomainId Displays the domain ID of the neighbor on this VSAN.

Neighbors—PortIndex Displays the port ID of the neighbor interface.

CreateTime Displays the time this interface was created.

10-7Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 166: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 10 Managing Fibre Channel Routing and FSPFConfiguring FSPF

Table 10-8 describes the configurable attributes for FSPF interfaces.

Viewing FSPF StatisticsTo monitor FSPF statistics from the Fabric Manager, choose FC > FSPF > Statistics on the menu tree. To monitor FSPF statistics from the Device Manager, choose FSPF from the FC menu and click the Statistics tab. Both dialog boxes show the display-only information described in Table 10-9.

Table 10-8 FC > FSPF > Interfaces—Configurable Attributes

Configurable Attribute Description

Cost Specifies the administrative cost of sending a frame on this interface on this VSAN; the lower the cost, the better.

AdminStatus Enables or disables FSPF on this interface on the VSAN. Valid values are up and down.

Intervals (sec)—Hello Specifies the interval between the HELLO messages sent on this interface on this VSAN to verify the link health.

Note This value must be same on both of the interfaces on each end of the link on this VSAN.

Intervals (sec)—Dead Specifies the maximum time for which no HELLO messages can be received on this interface on this VSAN. After this time, the interface is assumed to be broken and removed from the database.

This attribute’s value must be greater than the HELLO interval specified on this interface on this VSAN.

Intervals (sec)—Retransmit Specifies the time after which an unacknowledged link update is retransmitted on this interface on this VSAN.

Table 10-9 FC > FSPF > Statistics—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan Displays the VSAN ID.

SpfComputations Displays the number of times the SPF computation has been done on this VSAN since the creation of the entry.

ErrorRxPkts Displays the number of invalid FSPF control packets received on all the interfaces on this VSAN since the creation of the entry.

10-8Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 167: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 10 Managing Fibre Channel Routing and FSPFConfiguring FSPF

Viewing FSPF Interface StatisticsTo monitor FSPF interface statistics from the Fabric Manager, choose FC > FSPF > Statistics > Interface on the menu tree. To monitor FSPF interface statistics from the Device Manager, choose FSPF from the FC menu and click the Interface Stats tab. Both dialog boxes show the display-only information described in Table 10-10.

ChecksumErrors Displays the number of FSPF checksum errors that occurred on this VSAN since the creation of the entry.

LinkStateUpdates—RxPkts Displays the total number of link state update (LSU) packets received on all the interfaces on this VSAN since the creation of the entry.

LinkStateUpdates—TxPkts Displays the total number of LSU packets transmitted on all the interfaces on this VSAN since the creation of the entry.

LinkStateUpdates—RetranTxPkts Displays the total number of LSU packets retransmitted on all the interfaces on this VSAN since the creation of the entry.

LinkStateAcks—RxPkts Displays the total number of link state acknowledgment (LSA) packets received on all the interfaces on this VSAN since the creation of the entry.

LinkStateAcks—TxPkts Displays the total number of LSA packets transmitted on all the interfaces on this VSAN since the creation of the entry.

Hellos—RxPkts Displays the total number of HELLO packets received on all the interfaces on this VSAN since the creation of the entry.

Hellos—TxPkts Displays the total number of HELLO packets transmitted on all interfaces on this VSAN since the creation of the entry.

MaxAgeCount Displays the number of times any LSR reached the maximum age in this VSAN since the creation of the entry.

Table 10-9 FC > FSPF > Statistics—Display-Only Attributes (continued)

Display-Only Attribute Description

Table 10-10 FC > FSPF > Interface Stats—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan, Port Displays the VSAN ID and port ID.

CreateTime Displays the time this interface was created.

10-9Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 168: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 10 Managing Fibre Channel Routing and FSPFConfiguring FSPF

Viewing Link State RecordsTo monitor FSPF LSRs from the Device Manager, choose FSPF from the FC menu and click the LSDB LSRs tab. The dialog box shows the display-only information described in Table 10-11.

ErrorRxPkts Displays the number of invalid FSPF control packets received on this interface on this VSAN since the creation of the interface.

InactivityExpirations Displays the number of times the inactivity timer has expired on this interface on this VSAN since the creation of the interface.

LinkStateUpdates—RxPkts Displays the number of link state update (LSU) packets received on this interface on this VSAN since the creation of the interface.

LinkStateUpdates—TxPkts Displays the number of LSU packets transmitted on this interface on this VSAN since the creation of the interface.

LinkStateUpdates—RetranTxPkts Displays the number of LSU packets retransmitted on this interface on this VSAN since the creation of the interface.

LinkStateAcks—RxPkts Displays the number of link state acknowledgment (LSA) packets received on this interface on this VSAN since the creation of the interface.

LinkStateAcks—TxPkts Displays the number of LSA packets transmitted on this interface on this VSAN since the creation of the interface.

Hellos—RxPkts Displays the number of HELLO packets received on this interface on this VSAN since the creation of the interface.

Hellos—TxPkts Displays the number of HELLO packets transmitted on this interface on this VSAN since the creation of the interface.

Table 10-10 FC > FSPF > Interface Stats—Display-Only Attributes (continued)

Display-Only Attribute Description

Table 10-11 FC > FSPF > LSDB LSRs—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan, DomainId Displays the VSAN ID and the domain ID of the local switch on this VSAN.

AdvDomainId Displays the domain ID of the switch that is advertising the LSR on behalf of the switch that owns it.

10-10Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 169: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 10 Managing Fibre Channel Routing and FSPFConfiguring FSPF

Viewing FSPF LinksTo view FSPF links from the Device Manager, choose FSPF from the FC menu and click the LSDB Links tab. The dialog box shows the display-only information described in Table 10-12.

Age Displays the time since this LSR was inserted into the database.

IncarnationNumber Displays the link state incarnation number of this LSR.

This number identifies the most recent instance of an LSR, while updating the topology database when an LSR is received.

Displays when an LSR is updated and increments its incarnation number before the updated LSR is transmitted. The most recent LSR is the one with the larger incarnation number.

CheckSum Displays the checksum of the LSR.

Links Displays the number of links associated with this LSR.

Table 10-11 FC > FSPF > LSDB LSRs—Display-Only Attributes (continued)

Display-Only Attribute Description

Table 10-12 FC > FSPF > LSDB Links—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan, DomainId Displays the VSAN ID and the domain ID of the local switch on this VSAN.

NbrDomainId Displays the domain ID of the neighbor on the other end of this link on this VSAN.

PortIndex Displays the source E_port of this link.

NbrPortIndex Displays the destination E_port of this link.

Cost Displays the cost of sending a frame on this link on this VSAN.

10-11Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 170: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 10 Managing Fibre Channel Routing and FSPFConfiguring FSPF

10-12Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 171: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected] documentation

Cisco MDS 78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

C H A P T E R 11

Managing Advanced Features

Cisco MDS 9000 Family switches support advanced features, such as world wide names, domains, and name server. The Fabric Manager allows you to configure these features on multiple Cisco 9000 switches. The Device Manager allows you to configure these advanced features on a single Cisco 9000 switch. This chapter describes how to configure these advanced features using the Fabric Manager and Device Manager.

Note For information about these advanced features and configuring them using the command-line interface (CLI), refer to the Cisco 9000 Family Configuration Guide.

This chapter includes the following information:

• Managing World Wide Names, page 11-1

• Managing Domain Parameters, page 11-3

• Configuring the Name Server, page 11-10

• Viewing RSCN Information, page 11-15

• Configuring Timers, page 11-16

• Configuring Virtual Routing Redundancy Protocol (VRRP), page 11-18

Managing World Wide NamesEach port on a Cisco MDS 9000 Family switch is uniquely identified by its world wide names (WWNs), which include the switch MAC address and an identifier for each port. The principal switch selection and the allocation of domain IDs use the WWN to identify a specific port.

To add WWNs from the Fabric Manager, choose FC > WWN Manager on the menu tree. The dialog box from the Fabric Manager displays WWN information for multiple switches. To add WWNs from the Device Manager, choose WWN Manager from the FC menu. The dialog box from the Device Manager displays WWNs for a single switch.

Both dialog boxes show the display-only information described in Table 11-1.

11-19000 Family Fabric Manager User Guide

Page 172: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesManaging World Wide Names

Table 11-2 describes the configurable attributes for the WWN.

Table 11-1 FC > WWN Manager—Display-Only Attributes

Display-Only Information Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Type 1 WWNs: Max Displays the maximum number of Type 1 WWNs available for assignment to internal entities. The IEEE publishes standards for three formats for 48-bit WWNs:

• Type 1

• Extended Type 2

• Type 5 Registered

Type 1 WWNs: Available Displays the number of Type 1 WWNs currently available for assignment to internal entities.

Type 1 WWNs: Reserved Displays the number of Type 1 WWNs reserved and unavailable for use.

Type 2&5/Other WWNs: Max Displays the maximum number of total WWNs of types Type 2 and Type 5 available for assignment to internal entities.

Type 2&5/Other WWNs: Available Displays the sum total of Type 2 and Type 5 WWNs currently available for assignment to the internal entities.

Type 2&5/Other WWNs: Reserved Displays the number of Type 1 WWNs reserved and unavailable for use.

SwitchWWN Displays the WWN for the switch (Fabric Manager only)

Table 11-2 FC > WWN Manager—Configurable Attributes

Configurable Attribute Description

BaseMacAddress Specifies the first MAC address used for generating WWNs when the default range of WWNs generated from supervisor MAC addresses is exhausted.

MacAddressRange Specifies the number of secondary MAC addresses starting from and including the WWN SecondayBaseMacAddress.

11-2Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 173: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesManaging Domain Parameters

Managing Domain ParametersThis section describes how to configure domain parameters and includes the following topics:

• Viewing Domain Information, page 11-6

• Configuring Domain Attributes, page 11-4

• Viewing Domain Information, page 11-6

• Viewing Domain Manager Statistics, page 11-6

• Configuring Domain Interfaces, page 11-7

• Configuring Persistent FCIDs, page 11-8

• Viewing Domain Areas, page 11-8

• Viewing Domain Area Ports, page 11-10

Managing Running Attributes for DomainsTo view running domain attributes from the Fabric Manager, choose FC > Domain Manager > Running on the menu tree. The dialog box from the Fabric Manager displays domain attributes for multiple switches.

To view running domain attributes from the Device Manager, choose Domain Manager from the FC menu and click the Running tab. The Domain Manager dialog box, with the Running tab selected, displays domain attributes for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-3.

Table 11-3 FC > Domain Manage > Principal—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan Displays the VSAN ID.

State Displays the state of the Domain Manager on the local switch on this VSAN.

Local Switch: DomainId Displays the Domain Id of the local switch on this VSAN or zero if no Domain Id has been assigned.

Local Switch: WWN Displays the WWN of the local switch on this VSAN.

Local Switch: Priority Displays the priority value, used in the principal switch selection process, for the current switch.

Principal Switch: WWN Displays the WWN of the principal switch on this VSAN, or zero (0) if the identity of the principal switch is unknown.

Principal Switch: Priority Displays the priority value, used in the principal switch selection process, for the principal switch.

11-3Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 174: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesManaging Domain Parameters

Configuring Domain AttributesFrom this dialog box you can specify a fabric name for fabric logins on the VSAN and set the priority for the switch used in the principal switch selection process.

Table 11-4 describes the configurable principal attributes for the domain.

To manage domain attributes from the Fabric Manager, choose FC > Domain Manager > Configuration on the menu tree. The dialog box from the Fabric Manager lets you manage domain attributes for multiple switches.

To manage domain attributes from the Device Manager, choose Domain Manager from the FC menu and click the Configuration tab. The Device Manager dialog box displays domain attributes for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-5.

Table 11-6 describes the configurable attributes for the domain.

Table 11-4 FC > Domain Manage > Principal—Configurable Attributes

Configurable Attribute Description

FabricName Specifies the WWN that is used for fabric logins on this VSAN.

This attribute is available only if principal switch selection is used.

Priority Specifies the priority of the switch used in the principal switch selection process.

State Displays the operating state of the VSAN. Click the State heading to sort the information in ascending or descending order.

Table 11-5 FC > Domain Manager > Configuration—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan Displays the VSAN ID.

11-4Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 175: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesManaging Domain Parameters

Table 11-6 FC > Domain Manager > Configuration—Configurable Attributes

Configurable Attribute Description

Enable Enables or disables principal switch selection on this VSAN.

• If enabled on an active VSAN, the switch participates in principal switch selection.

• If disabled, the switch does not participate in the principal switch selection or in domain allocation. In this case, the domain ID must be configured statically.

ConfigDomain: Id Specifies the configured domain ID of the local switch on this VSAN, or zero if no domain ID has been configured.

ConfigDomain: IdType Click to select the type of configured Domain ID. Valid values are:

• static

• preferred

FabricName Specifies the WWN that is used for fabric logins on this VSAN.

This attribute is available only if principal switch selection is used.

Priority Specifies the priority of the switch used in the principal switch selection process.

ContiguousAllocation Specifies how the switch behaves when elected as the principal switch.

Check the check box to enable or disable the ContiguousAllocation feature.

• When enabled, the switch does not accept noncontiguous domain IDs, and attempts to replace all domain IDs in the list with contiguous domain IDs.

• When disabled, the switch grants the domain IDs, even if they are noncontiguous.

11-5Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 176: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesManaging Domain Parameters

Viewing Domain InformationTo view domain information from the Device Manager, choose Domain Manager from the FC menu and click the Domains tab. The dialog box displays domain information for a single switch and shows the display-only attributes described in Table 11-7.

Viewing Domain Manager StatisticsTo monitor domain manager statistics from the Fabric Manager, choose FC > Domain Manager > Statistics on the menu tree. The dialog box from the Fabric Manager displays domain statistics for multiple switches.

To monitor domain manager statistics from the Device Manager, choose Domain Manager from the FC menu and click the Statistics tab. The Domain Manager dialog box, with the Statistics tab selected, displays domain statistics for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-8.

AutoReconfigure Specifies how the switch responds if two disjointed fabrics with overlapping domain ID lists merge.

Check the check box to enable or disable the AutoReconfigure feature.

• When enabled, the switch rebuilds the fabric.

• When disabled, the switch isolates the E_ports on which the errors occurred.

Restart Specifies whether the domain manager is to reconfigure the fabric and rebuild the domain ID tree again in case of errors. Valid values are:

• nonDisrup

• disruptive

• noOp

Table 11-6 FC > Domain Manager > Configuration—Configurable Attributes (continued)

Configurable Attribute Description

Table 11-7 FC > Domain Manager > Domains—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan, DomainId Displays the VSAN ID and the domain ID.

SwitchWwn Displays the WWN of the switch on this VSAN.

11-6Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 177: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesManaging Domain Parameters

Configuring Domain InterfacesTo configure domain interfaces from the Fabric Manager, choose FC > Domain Manager > Interfaces on the menu tree. The dialog box from the Fabric Manager displays domain interfaces for multiple switches.

To configure domain interfaces from the Device Manager, choose Domain Manager from the FC menu and click the Interfaces tab. The Domain Manager dialog box, with the Interfaces tab selected, displays domain interfaces for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-9.

Table 11-10 describes the configurable attributes for domain interfaces.

Table 11-8 FC > Domain Manager > Statistics—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan Displays the VSAN ID.

PrincipalSwitchSelections Displays the number of principal switch selections on this VSAN.

Fabrics—Builds Displays the number of fabric builds on this VSAN.

Fabrics—Reconfigures Displays the number of fabric reconfigures on this VSAN.

Fcid—Granted Displays the number of FC IDs granted for use on the local switch since the switch was initialized.

Fcid—Recovered Displays the number of FC IDs recovered on the local switch since the switch was initialized.

Fcid—Free Displays the number of FC IDs unassigned for the VSAN.

Fcid—Assigned Displays the number of FC IDs assigned for the VSAN.

Fcid—Reserved Displays the number of FC IDs reserved for the VSAN.

Table 11-9 FC > Domain Manager > Interfaces—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan, Interface Displays the VSAN ID and port ID.

Role Displays the role of this interface.

11-7Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 178: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesManaging Domain Parameters

Viewing Domain AreasTo monitor domain areas from the Fabric Manager, choose FC > Domain Manager > Domain > Areas on the menu tree. The dialog box from the Fabric Manager displays domain areas for multiple switches.

To monitor domain areas from the Device Manager, choose Domain Manager from the FC menu and click the Areas tab. The Domain Manager dialog box, with the Areas tab selected, displays domain areas for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-11.

Configuring Persistent FCIDsTo configure persistent FCIDs from the Fabric Manager, choose FC > Domain Manager > Persistent FCIDs on the menu tree. The dialog box from the Fabric Manager displays persistent FCIDs for multiple switches.

To configure persistent FCIDs from the Device Manager, choose Domain Manager from the FC menu and click the Persistent FCIDs tab. The Domain Manager dialog box, with the Persistent FCIDs tab selected, displays persistent FCIDs for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-9.

Table 11-10 FC > Domain Manager > Interfaces—Configurable Attributes

Configurable Attribute Description

RcfReject Enables or disables RcfReject messages on this interface. If enabled, incoming RCF messages are rejected on this interface. If disabled, incoming RCF messages are accepted on this interface.

Table 11-11 FC > Domain Manager > Areas—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan Displays the VSAN ID.

AssignedAreaIdList Displays the list of area IDs assigned in this VSAN.

Table 11-12 FC > Domain Manager > Persistent FCIDs—Display-Only Attributes

Display-Only Attribute Description

VsanID, WWN Displays the VSAN ID and the WWN of the switch on this VSAN.

Used Displays True if the FC ID is being used; False if the FC ID is not being used.

11-8Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 179: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesManaging Domain Parameters

Table 11-10 describes the configurable attributes for persistent FCIDs.

Before you can create persistent FCIDs, you must:

• Configure a static domain ID in that VSAN

• Ascertain that the static configured domain and the runtime domain are the same. You can verify this using the show fcdomain command. For information about using the command line interface (CLI), refer to the Cisco 9000 Family Configuration Guide.

Note If you connect to the switch from an AIX or HP-UX host, be sure to create the persistent FC ID in the VSAN that connects these hosts.

Note Persistent FC IDs with loop-attache devices (FL ports) need to remain connected to the same port in which they were configured.

To create a new persistent FCID, do the following:

Step 1 Click the Create button.

The Create Domain Manager Persistent FCIDs dialog is displayed.

Step 2 Enter the VSAN ID.

Step 3 Enter the WWN.

Step 4 Enter the FCID.

Step 5 Select the Mask.

This is the number of FC IDs which are assigned either statically or dynamically for this WWN on this VSAN. Possible values are Single, meaning just one FCI ID is assigned, or Area, meaning all of the FC IDs in the area that is specified are assigned.

Step 6 Select the Assignment.

This is the type of persistency of this FC ID (static or dynamic).

Table 11-13 FC > Domain Manager > Persistent FCIDs—Configurable Attributes

Configurable Attribute Description

FcId Displays the FC ID assigned for this WWN on this VSAN.

Mask Displays the number of FC IDs which are assigned either statically or dynamically for this WWN on this VSAN. Possible values are Single, meaning just one FCI ID is assigned, or Area, meaning all of the FC IDs in the area that is specified are assigned.

Assignment Displays the type of persistency of this FC ID (static or dynamic).

11-9Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 180: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesConfiguring the Name Server

Step 7 Click Create to create the persistent FCID; click Close to return to the Domain Manager without creating the FCID.

To delete a persistent FCID, do the following.

Step 1 Select the persistent FCID you want to delete.

The Delete button is enabled.

Step 2 Click the Delete button to delete the FCID.

Viewing Domain Area PortsTo monitor area ports for domains from the Fabric Manager, choose FC > Domain Manager > Domain > Area Ports on the menu tree. The FC dialog box from the Fabric Manager displays area ports for domains for multiple switches.

To monitor area ports for domains from the Device Manager, choose Domain Manager from the FC menu and click the Area Ports tab. The Domain Manager dialog box, with the Area Ports tab, displays area ports for domains for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-14.

Configuring the Name ServerConfiguring the Name Server includes the following tasks.

• Viewing General Attributes for the Name Server, page 11-10

• Viewing Advanced Attributes for the Name Server, page 11-11

• Proxy Ports for the Name Server, page 11-12

• Viewing Name Server Statistics, page 11-13

Viewing General Attributes for the Name ServerTo view general name server attributes from the Device Manager, choose Name Server from the FC menu. The Name Server dialog box, with the General tab selected, displays name server attributes for a single switch. This dialog box shows the display-only attributes described in Table 11-15.

Table 11-14 FC > Domain Manager > Area Ports—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan, AreaId Displays the VSAN ID and area ID.

Ports Displays the list of port IDs assigned in this area and VSAN.

11-10Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 181: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesConfiguring the Name Server

Viewing Advanced Attributes for the Name ServerTo monitor advanced name server attributes from the Device Manager, choose Name Server from the FC menu and click the Advanced tab. The Name Server dialog box, with the Advanced tab selected, displays advanced name server attributes for a single switch. This dialog box shows the display-only attributes described in Table 11-16.

Table 11-15 FC > Name Server > General—Display-Only Attributes

Display-Only Attribute Description

Vsan, Fcid Displays the VSAN ID and Fibre Channel ID.

Type Displays the type of this port. Valid values are:

• Nx_port

• Fx_port

• xE_port

PortName Displays the Fibre Channel port name (or WWN) for this Nx_port.

NodeName Displays the Fibre Channel node name (or WWN) for this Nx_port.

FabricPortName Displays the fabric port name (WWN) of the Fx_port to which this Nx_port is attached.

ClassOfSvc Displays the class of service supported by the port. Zero (0) indicates that this port does not support any class of service.

FC4Type Displays the FC-4 protocol types supported by this Nx_port.

FC4Features Displays the FC-4 features associated with this port and FC-4 type (which shows if the port is the target or initiator).

Table 11-16 FC > Name Server > Advanced—Display-Only Attributes

Display-Only Attribute Description

Vsan, Fcid Displays the VSAN ID and Fibre Channel ID.

PortIpAddress Displays the IP address of the associated port.

SymbolicNodeName Displays the user-defined node name for this port.

SymbolicPortName Displays the user-defined name of this port.

NodeIpAddress Displays the IP address of the node for this Nx_port.

HardAddress If the port is not an NL_port or if it does not have a hard address, this attribute displays all zeros (0).

ProcAssoc Displays the Fibre Channel initial process associator (IPA).

11-11Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 182: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesConfiguring the Name Server

Proxy Ports for the Name ServerTo configure proxy ports for the name server from Fabric Manager, choose FC > Name Server Proxies on the menu tree. The dialog box from the Fabric Manager displays name server proxy ports for multiple switches.

To configure proxy ports for the name server from the Device Manager, choose Name Server from the FC menu and click the Proxy tab. The Name Server dialog box, with the Proxy tab selected, displays name server proxies for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-17.

Table 11-18 displays the configurable proxy attributes for the name server.

Table 11-17 FC > Name Server > Proxies—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan Displays the VSAN ID.

Table 11-18 FC > Name Server > Proxies—Configurable Attributes

Configurable Attribute Description

PortName Specifies the name of the proxy port that can register or deregister for other ports on this VSAN. Use the proxy attribute to enable third party registrations.

11-12Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 183: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesViewing LUN Information

Viewing Name Server StatisticsTo monitor name server statistics from the Fabric Manager, choose FC > Name Server Statistics on the menu tree. The dialog box from the Fabric Manager displays name server statistics for multiple switches.

To monitor name server statistics from the Device Manager, choose Name Server from the FC menu and click the Statistics tab. The Name Server dialog box, with the Statistics tab selected, displays name server statistics for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-19.

Viewing LUN InformationThis section describes how to manage LUN information and includes the following topics:

• Configuring LUN Discovery, page 11-13

• Viewing Logical Unit Information, page 11-14

• Viewing LUNs Information, page 11-15

Configuring LUN DiscoveryTo view logical unit number (LUN) information from the Device Manager, choose LUN from the FC menu. The dialog box shows the display-only attributes described in Table 11-20.

Table 11-19 FC > Name Server > Statistics

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan Displays the VSAN ID.

Queries—Rx Displays the total number of queries received by the local switch on this VSAN.

Queries—Tx Displays the total number of queries sent by the local switch on this VSAN.

Requests Rx—Reg Displays the total number of registration requests received by the local switch on this VSAN.

Requests Rx—DeReg Displays the total number of deregistration requests received by the local switch on this VSAN.

Rscns—Rx Displays the total number of RSCN commands received by the local switch on this VSAN.

Rscns—Tx Displays the total number of RSCN commands sent by the local switch on this VSAN.

Rejects Tx Displays the total number of requests rejected by the local switch on this VSAN.

11-13Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 184: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesViewing LUN Information

Viewing Logical Unit InformationTo view logical unit number (LUN) information from the Device Manager, choose LUN from the FC menu and click the Logical Units tab. The dialog box shows the display-only attributes described in Table 11-21.

Table 11-20 LUN Discover

Display-Only Attribute Description

StartDiscovery Determines the scope of LUN discovery. Click local to restrict discovery to directly attached SCSI target devices, ports and LUNs on all VSANs. Click Remote to discover all SCSI target devices, ports and LUNs in the fabric except for those that are directly attached. Click both to discover for both local and remote discovery.

Results—Status Displays the outcome of the LUN discovery on the local switch. The possible values are:

• inProgress—Indicates that the discovery is still in progress

• completed—Indicates that the discovery is complete

• failure—Indicates that the discovery encountered a failure

CompleteTime Displays the elapsed time since the last system restart when the last discovery was completed.

Table 11-21 LUN Discover—Display-Only Attributes

Display-Only Attribute Description

VsanId The VSAN to which this target belongs.

Port WWN The name of this authorized and discovered target device or port.

DevType The device type of the SCSI target.

VendorId The vendor ID of the SCSI target.

ProductId The product ID of the SCSI target.

RevLevel The product revision level of the SCSI target.

OtherInfo The bytes from 0 to 7 in the INQUIRY command response data.

11-14Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 185: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesViewing RSCN Information

Viewing LUNs InformationTo view LUNs information from the Device Manager, choose LUN from the FC menu and click the LUNs tab. The dialog box shows the display-only attributes described in Table 11-22.

Viewing RSCN InformationThis section describes how to view RSCN information and includes the following topics:

• Viewing RSCN Nx Registrations, page 11-15

• Viewing RSCN Statistics, page 11-16

Viewing RSCN Nx RegistrationsTo view Nx registrations for RSCN from the Fabric Manager, choose FC > RSCN Registrations on the menu tree. The dialog box from the Fabric Manager displays Nx registrations for RSCN for multiple switches.

To monitor Nx registrations for RSCN from the Device Manager, choose RSCN from the FC menu. The RSCN dialog box, with the Nx Registrations tab selected, displays Nx registrations for RSCN for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-23.

Table 11-22 LUN Discover—Display-Only Attributes

Display-Only Attribute Description

Id The number of this LUN.

Capacity (M) The capacity of this LUN.

SerialNum The serial number of this LUN.

Table 11-23 FC > RSCN Registrations—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan, FcId Displays the VSAN ID and Fibre Channel ID.

RegType Displays the registration desired by the subscriber. Valid values are:

• fromFabricCtrlr—Indicates RSCNs generated by the fabric controller

• fromNxPort—Indicates RSCNs generated by the Nx_port

• fromBoth—Indicates RSCNs generated by both the fabric controller and the Nx_port

11-15Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 186: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesConfiguring Timers

Viewing RSCN StatisticsTo monitor registered state change notification (RSCN) statistics from the Fabric Manager, choose FC > RSCN Statistics on the menu tree. The dialog box from the Fabric Manager displays RSCN statistics for multiple switches.

To monitor RSCN from the Device Manager, choose RSCN from the FC menu and click the Statistics tab. The RSCN dialog box, with the Statistics tab selected, displays RSCN statistics for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-24.

Configuring TimersTo configure timers from the Fabric Manager, choose FC > Timers on the menu tree. The dialog box from the Fabric Manager displays timers for multiple switches.

To configure timers from the Device Manager, choose Timers/Policies from the FC menu. The dialog box from the Device Manager displays timers for a single switch.

Both dialog boxes show the display-only attributes described in Table 11-25.

Table 11-24 FC > RSCN > Statistics—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

Vsan Displays the VSAN ID.

RxScrs Displays the number of State Change Registrations (SCRs) received from Nx_Ports on this VSAN.

ScrRej Displays the number of SCRs rejected on this VSAN.

RxRscns Displays the number of RSCNs received from Nx_Ports on this VSAN.

TxRscns Displays the number of RSCNs transmitted from Nx_Ports on this VSAN.

RscnReqRej Displays the number of RSCN requests rejected on this VSAN.

RxSwRscns Displays the number of interswitch RSCNs received from other switches on this VSAN.

TxSwRscns Displays the number of interswitch RSCNs transmitted to other switches on this VSAN.

SwRscnReqRej Displays the number of interswitch RSCN requests rejected on this VSAN.

11-16Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 187: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesConfiguring Timers

Table 11-26 describes the configurable timer attributes.

Table 11-25 FC > Timers—Display-Only Attributes

Display-Only Attribute Description

Switch Displays the switch ID. This attribute is only displayed from the Fabric Manager.

F_S_TOV Displays the fabric stability timeout value, which ensures fabric stability during fabric configuration.

Drop Latencies—Switch Displays the drop latency for the switch in milliseconds.

Table 11-26 FC > Timers—Display-Only Attributes

Configurable Attribute Description

R_A_TOV Specifies the resource allocation timeout value for FxPorts for determining when to reuse an NxPort resource, such as a recovery qualifier. Note that all switches in a fabric should be configured with the same value for this timeout. Valid values are 5000 to 15000 ms.

E_D_TOV Specifies the error detect timeout value used for FxPorts for detecting an error condition. Note that all switches in a fabric should be configured with the same value for this timeout. Valid values are 2000 to 100000 ms.

D_S_TOV Specifies the distributed services timeout value, which indicates how long a distributed services requestor waits for a response. Valid values are 5000 to 100000 ms.

Policies—InorderDelivery If enabled, then the in order delivery is guaranteed. If disabled, it is not guaranteed.

Policies—TrunkProtocol Enables the trunking protocol. The trunking protocol is used for negotiating trunk mode and calculating operational VSANs on an EISL link. It also performs port VSAN consistency checks. On non-trunking ISL links, if the port VSANs are different, the E ports will be isolated. To avoid this isolation, disable this parameter.

11-17Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 188: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesConfiguring Virtual Routing Redundancy Protocol (VRRP)

Configuring Virtual Routing Redundancy Protocol (VRRP)Cisco MDS 9000 Family switches support the Virtual Router Redundancy Protocol (VRRP), as described in RFC 2338. VRRP provides redundant paths to a gateway switch. For further information about VRRP, refer to the Cisco MDS 9000 Family Configuration Guide.

This section describes how to use Device Manager to configure VRRP and includes the following information:

• Configuring VRRP Operations Attributes, page 11-18

• Managing IP Addresses for VRRP, page 11-20

• Viewing VRRP Statistics, page 11-21

Configuring VRRP Operations AttributesTo configure VRRP operations attributes from Device Manager, choose VRRP option from the IP menu. Figure 11-1 shows the VRRP dialog box with the Operations tab selected.

Figure 11-1 VRRP Dialog Box, Operations View

The VRRP Operations view shows the display-only attributes described in Table 11-27.

Table 11-27 VRRP Operations—Display-Only Attributes

Display-Only Attribute Description

Interface, VrId Displays the port ID and virtual router ID.

Stat—Admin Enables/disables the virtual router, as follows:

• up—transitions the virtual router from the initialized state to either backup or master.

• down—transitions the virtual router from either master or backup to the initialized state.

11-18Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 189: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesConfiguring Virtual Routing Redundancy Protocol (VRRP)

Table 11-28 describes the configurable Operations attributes for the virtual router.

To create a new VRRP entry, click the Create button. You see the window shown in Figure 11-2.

Stat—Oper Displays the current operational state of the virtual router. Valid values are:

• initialize—indicates that the virtual router is waiting for a startup event.

• backup—indicates that the virtual router is monitoring the availability of the master router.

• master—indicates that the virtual router is forwarding packets for IP addresses associated with this router.

VirtualMacAddr Displays the number of IP addresses associated with this virtual router.

MasterIpAddr Displays the master router's primary IP address. This is the IP address listed as the source in the last VRRP advertisement received by this virtual router.

Table 11-27 VRRP Operations—Display-Only Attributes (continued)

Display-Only Attribute Description

Table 11-28 VRRP Operations—Display-Only Attributes

Configurable Attribute Description

Auth—Type Specifies the authentication type used for VRRP exchanges between virtual routers.

Auth—Key Specifies the authentication key.

Priority Specifies the priority to be used for the virtual router master election process. Higher values imply higher priority. A priority of zero (0) is sent by the master router to indicate that this router has ceased to participate in VRRP and a backup virtual router should transition to become a new master. A priority of 255 is used for the router that owns the associated IP addresses.

AdvertisementInterval Specifies the time interval, in seconds, between sending advertisement messages. Only the master router sends VRRP advertisements.

PreemptMode Enables a higher priority virtual router to preempt a lower priority master.

UpTime Displays the time this virtual router transitioned out of the initialized state.

11-19Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 190: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesConfiguring Virtual Routing Redundancy Protocol (VRRP)

Figure 11-2 Create VRRP

Complete the fields on this window to create a new VRRP entry, and click OK or Apply.

Managing IP Addresses for VRRPTo manage IP addresses for virtual routers from Device Manager, click the IP Addresses tab on the VRRP dialog box.

Figure 11-3 shows the VRRP dialog box with the IP Addresses tab selected.

Figure 11-3 VRRP Dialog Box, IP Addresses View

This window shows the display-only attributes described in Table 11-29.

To create a new VRRP entry, click the Create button. You see the window shown in Figure 11-4.

Table 11-29 VRRP IP Addresses Tab—Display-Only Attributes

Display-Only Attribute Description

Port, VrId, Address Displays the port ID, virtual router ID, and IP address.

Status Adds/deletes an associated IP address for the virtual router.

11-20Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 191: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesConfiguring Virtual Routing Redundancy Protocol (VRRP)

Figure 11-4 Create VRRP IP Addresses

Complete the fields on this window to create a new VRRP IP Address, and click OK or Apply.

Viewing VRRP StatisticsTo monitor VRRP statistics, click the Statistics tab on the VRRP dialog box. Figure 11-5 shows the VRRP dialog box with the Statistics tab selected.

Figure 11-5 VRRP Statistics

This window shows the display-only attributes described in Table 11-30.

Table 11-30 VRRP Statistics Tab—Display-Only Attributes

Display-Only Attribute Description

Protocol— BecomeMaster The total number of times that this virtual router's state has transitioned to MASTER.

Protocol— AdvertiseRcvd The total number of VRRP advertisements received by this virtual router.

0-Priority-Err— Rx The total number of VRRP packets received with a priority of 0.

0-Priority-Err— Tx The total number of VRRP packets sent with a priority of 0.

Auth— Failures The total number of VRRP packets received that do not pass the authentication check.

Auth— InvalidTypes The total number of packets received with an unknown authentication type.

Auth— TypeMismatchs The total number of packets that do not match the locally configured authentication method.

11-21Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 192: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Chapter 11 Managing Advanced FeaturesConfiguring Virtual Routing Redundancy Protocol (VRRP)

Other Errors— AdvertiseInterval The total number of VRRP advertisement packets received for which the advertisement interval is different than the one configured for the local virtual router.

Other Errors— TTL The total number of VRRP packets received by the virtual router with IP TTL (Time-To-Live) not equal to 255.

Other Errors— InvalidTypeRx The number of VRRP packets received by the virtual router with an invalid value in the 'type' field.

Other Errors— AddressList The total number of packets received for which the address list does not match the locally configured list for the virtual router.

Other Errors— PacketLength The total number of packets received with a packet length less than the length of the VRRP header.

Table 11-30 VRRP Statistics Tab—Display-Only Attributes (continued)

Display-Only Attribute Description

11-22Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 193: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Cisco MDS 90078-14895-01, Cisco MDS SAN-OS Release 1.0(2)

I N D E X

A

access control 5-1

accessing Cisco Fabric Manager 1-9

activating

zone sets 3-6

active zone set 3-3

adding

Fibre Channel routes 10-3

IP route 4-6

PortChannels 7-13

RADIUS servers 5-9

route flows 10-5

SNMP communities 5-3

SNMP user 5-3

syslog servers 8-25

VSANs 4-1, 4-4

zone members 3-5

zones 3-4

administrator access

configuring 5-1

users and roles 1-7

advanced features 11-1

alarms

RMON attributes 8-11

See RMON

alerts

configuring Call Home 8-21

aliases

specifying for ports 7-3

ANSI T11 FC-GS-3 1-3

application management 1-3

area ports

viewing domain 11-10

areas, domain

See domain areas

authentication

See RADIUS authentication

See SNMP authentication

authentication digest 1-12

B

beacon mode

disabling 7-10

enabling 7-10

buffers

displaying 7-11

bytes, monitoring 7-17

C

Call Home 8-18

alerts 8-21

destinations 8-19

e-mail 8-21

events 8-1

profiles 8-22

capability attributes 7-11

cards, viewing information 9-6

charting

from Summary View 2-26

traffic statistics 7-17

chassis, viewing information 9-2

Class 2 errors, monitoring 7-19

class of service

IN-10 Family Fabric Manager User Guide

Page 194: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Index

See CoS

CLI

launching from Fabric View 2-13

security 5-8

using 1-5

community strings

required for discovery 2-6

SNMP 5-1

comparing Device View and Fabric View 2-21

configuration file

startup 6-2

connecting to supervisor module 1-10

connectivity

controlling in-band management 4-4

establishing management 1-4

verifying 2-10

copying

zones 3-4

CoS

displaying for Fx ports 7-5

displaying for xE ports 7-5

creating

enclosures 2-7

PortChannels 2-24

D

data management 1-3

default configuration 1-6

default gateway 4-5

default VSAN 4-2

default zone 3-3

default zone policy 3-7

defining, user roles 5-5

deleting zones 3-7

destinations, Call Home 8-19

device

status, legend 2-20

devices

IN-2Cisco MDS 9000 Family Fabric Manager User Guide

grouping 2-7

managing 1-2

Device View

compared to Fabric View 2-21

described 1-1, 1-8

launching 1-11, 2-20

using 2-19

disabling, ports 2-24, 7-1

discards

monitoring 7-18

discovering network fabric 1-6

Domain Manager

viewing statistics 11-6

domains

areas 11-8

configuring interfaces 11-7, 11-8

managing attributes 11-4

viewing area ports 11-10

viewing information 11-6

downloading

Cisco Fabric Manager software 1-10

switch software 6-2

E

editing zone information 3-2

ELP attributes 7-7

e-mail, Call Home 8-21

attributes 8-18

enabling

PortChannels 7-22

ports 2-24, 7-1

trunking 2-24, 7-22

VSANs 4-2

enclosures, creating 2-7

encryption, SNMPv3 1-12

end node loop ports

See NL ports

end-to-end connectivity

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 195: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected].

Index

See connectivity

entering IP addresses 1-12

errors

See Class 2 errors

See frame errors

See link errors

See sequence errors

events

configuring filters 8-6

configuring RMON 8-15

viewing RMON 8-16

viewing SNMP 8-2

Events tab 2-6

exchange link parameter attributes

See ELP attributes

expansion ports

See xEports

Extended Inter-Switch Link

See EISL

F

fabric

login attributes 7-5

management 1-2, 1-6

fabric configuration, analyzing 2-11

fabric login attributes

See FLOGI attributes

fabric loop ports

See Fx ports

fabric ports

See Fx ports

Fabric Shortest Path First

See FSPF

Fabric View 1-1

described 2-2

launching 1-11

main window described 2-2

Fibre Channel route flows 10-3

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Fibre Channel routes 10-1

File Transfer Protocol

See FTP

FLOGI attributes 7-5

frames

monitoring 7-18

FSPF

described 10-1

general attributes 10-6

interfaces 10-7

interface statistics 10-9

links 10-11

link state records 10-10

statistics 10-8

FTP 1-3

Fx ports

defined 7-2

managing general attributes 7-3

managing interface attributes 7-4

managing physical attributes 7-10

viewing FLOGI attributes 7-5

G

GBICs

displaying information 7-10

Gigabit Interface Converters

See GBICs

GS3

of ANSI T11 1-3

H

health

See switch health

hosts, viewing 2-18

HTTP

identifying port number 1-12

IN-3Cisco MDS 9000 Family Fabric Manager User Guide

Page 196: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Index

server 1-10

used by Fabric Manager 1-3

Hyptertext Transfer Protocol

See HTTP

I

ICMP statistics 4-12

images, downloading

See downloading images

in-band management

defined 1-4

routing 4-4

viewing information 4-7

Information pane

defined 2-3

described 2-5

initial setup 1-5

installing

Cisco Fabric Manager software 1-10

switch software 6-2

Internet Conrol Message Protocol statistics

See ICMP statistics

Inter-Switch Links

See ISL statistics

See ISL trunks

inventory 9-4

IP addresses

seed switch 1-12

viewing 4-7

IPFC

defined 1-4

managing connectivity 4-6

IP over Fibre Channel

See IPFC

IP routing 4-4

IP statistics 4-10

ISLs

viewing statistics 2-16

IN-4Cisco MDS 9000 Family Fabric Manager User Guide

ISL trunks 2-17

isolated VSANs 4-2

J

Java Virtual Machine

See SunJava Virtual Machine

Java Web Start 1-11

K

kickstart image

function 6-1

L

launching

Cisco Fabric Manager 1-11

CLI 2-13

Device View 2-20

line cards

See cards

link errors, monitoring 7-19

links

FSPF 10-11

link state acknowledgement packets

See LSA packets

link state records 10-10

See LSRs

link state update packets

See LSU packets

local console port 1-5

logical unit numbers

See LUNs

login screen 1-11

logs

configuring syslog 8-24

viewing RMON 8-16

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 197: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected].

Index

viewing SNMP 8-2

LSA packets

viewing 10-9

LSRs viewing 10-10

LSU packets

viewing 10-9

LUNs, viewing 2-19

M

MAC address

See WWN

management access 1-7

management traffic, routing 4-4

managing ports 2-24

Map pane

defined 2-3

described 2-6

MD5 1-12

members

adding to zones 3-5

deleting 3-7

displaying zones 3-7

menu bar

Fabric View 2-3

options 2-4

merging zones 2-12

message bar

Fabric View 2-3, 2-4

monitoring

bytes 7-17

Class 2 errors 7-19

discards 7-18

frame errors 7-21

port sequence errors 7-20

port statistics 7-16

SNMP traffic 4-12, 4-14

traffic 2-26

multiple switches

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

managing with Fabric View 1-2

N

name server

advanced attributes 11-11

general attributes 11-10

proxy ports 11-12

statistics 11-13

NL ports 7-2

Nx registrations

viewing 11-15

O

of 5-1

opening, fabric 2-6

out-of-band management

defined 1-4

P

panes

See Information pane

See Map pane

See VSAN/Switches pane

physical alarms, RMON 8-10

policies

default zone 3-3

setting for default zone 3-7

PortChannels

creating from Device View 2-24

interface attributes 7-14

managing 7-12, 7-22

ports

enabling 7-1

FLOGI attributes 7-5

link errors 7-19

IN-5Cisco MDS 9000 Family Fabric Manager User Guide

Page 198: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Index

managing general attributes 7-2

managing interface attributes 7-4

monitoring bytes 7-17

monitoring frames 7-18

monitoring statistics 7-16

PortChannels 7-12

sequence errors 7-20

trunking information 7-9

types defined 7-2

viewing capability attributes 7-11

viewing ELP attributes 7-7

viewing FLOGI attributes 7-5

power supplies, viewing information 9-7

principal attributes 11-3

priorities

syslog 8-27

Privacy option 1-12

private loop devices 7-2

profiles, Call Home 8-22

proxy ports, name server 11-12

proxy servers

using with Java WebStart 1-12

R

RADIUS

authentication 5-8

RADIUS servers

configuring 5-8

redundancy, viewing information 9-5

registered state change notification

see RSCN

remote access 1-3

remote monitoring

See RMON alarms

See RMON logs

reports, Fabric View 2-16

resizing panes 2-3

resource management 1-2

IN-6Cisco MDS 9000 Family Fabric Manager User Guide

RMON alarms

attributes 8-11

by port 8-8

defined 8-1

for VSANs 8-9

physical 8-10

RMON events 8-15, 8-16

RMON logs 8-16

roles

configuring SNMP 5-5

described 5-1

routing

Fibre Channel 10-2

FSPF 10-6

IP management traffic 4-4

RSCN

viewing Nx Registration 11-15

viewing statistics 11-16

S

SAN operating system

See SAN-OS 6-1

SAN-OS 6-1

searching zones 3-6

Secure File Transfer Protocol

See SFTP

Secure Shell Protocol

See SSH

security

configuring CLI administrator access 1-7, 5-1, 5-8

configuring SNMP access 1-7, 5-1

event destinations 8-5

seed switch

described 1-6

IP address 1-12

IP routing 4-5

sensors, viewing information 9-7

sequence errors 7-20

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 199: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected].

Index

setup dialog 1-5

SFTP 1-3

SNMP

monitoring traffic 4-14

Privacy option 1-12

SNMP communities

configuring 5-1

creating 5-3

SNMP events

defined 8-1

filters 8-6

software images

downloading 6-2

upgrading 6-1

speed

viewing for ports 7-14

SSH 1-3

starting Cisco Fabric Manager 1-11

static routes 4-5

statistics

FSPF 10-9

in-band management 4-7

ports 7-14

status bar 2-3

storage, viewing 2-18

storage management solutions architecture 1-2

summary of tasks 2-1

Summary View

attributes 2-26

described 1-1, 1-8

using 2-26

SunJava Virtual Machine 1-10

supervisor module

connecting to 1-4, 1-10

HTTP server 1-10

switch health 2-9

syslog

configuring 8-24

events 8-1

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

priorities 8-27

servers 8-25

system attributes 9-1

system image

function 6-1

T

tasks, summary of 2-1

Telnet 1-3

threshold manager, RMON 8-8

timers 11-16

TL ports 7-2

toolbar 2-3, 2-4

traceroute 2-13

traffic statistics

charting 2-26, 7-17

SNMP 4-12

translative loop ports

See TL ports

Trivial File Transfer Protocol

See TFTP

troubleshooting

Cisco Fabric Manager installation 1-12

switch configuration 2-9

with traceroute 2-13

trunking

enabling 2-24, 7-22

expansion ports 7-2

information 7-9

viewing mode 7-4

VSANs and 4-2

U

UDP, viewing 4-9

user roles

configuring 5-5

IN-7Cisco MDS 9000 Family Fabric Manager User Guide

Page 200: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Index

creating 5-6

users, SNMP 5-1

V

verifying

fabric configuration 2-11

zone configuration 2-12

viewing

card information 9-6

chassis information 9-2

domain information 11-6

hosts 2-18

ICMP statistics 4-12

in-band management information 4-7

inventory 9-4

IP addresses 4-7

IPFC information 4-6

IP statistics 4-10

ISL statistics 2-16

ISL trunks 2-17

LUNs 2-19

network fabric 1-6

port capability 7-11

PortChannel information 7-12

port information 7-3

power supply information 9-7

redundancy information 9-5

role information 5-7

sensor information 9-7

SNMP events 8-2

storage 2-18

switches 2-17

system attributes 9-1

trunking information 7-9

UDP information 4-9

VSAN information 4-3

zone statistics 3-9

VSAN/Switches pane

IN-8Cisco MDS 9000 Family Fabric Manager User Guide

described 2-4

location 2-3

VSANs

benefits 4-1

configuring 4-1

IP routing 4-5

RMON alarms 8-9

viewing associated ports 7-14

W

world wide names

See WWN

WWN

managing 11-1

X

xE ports

managing general attributes 7-2

managing interface attributes 7-4

managing physical attributes 7-10

viewing ELP attributes 7-7

viewing port capability attributes 7-11

viewing trunking information 7-9

Z

zones

adding members 3-5

cloning 3-4

deleting 3-7

managing 3-1

merging 2-12

statistics 3-9

zone server, managing 3-6

zone sets

activating 3-6

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

Page 201: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Send documentation comments to [email protected].

Index

adding zones 3-4

creating 3-1

deleting 3-7

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)

IN-9Cisco MDS 9000 Family Fabric Manager User Guide
Page 202: Cisco MDS 9000 Family Fabric Manager User Guide · Send documentation comments to Contents vi Cisco MDS 9000 Family Fabric Manager User Guide 78-14895-01, Cisco MDS SAN-OS Release

Sen d doc ume nta t i on c ommen ts to

Index

IN-10Cisco MDS 9000 Family Fabric Manager User Guide

78-14895-01, Cisco MDS SAN-OS Release 1.0(2)