circuit - wiring devices, accessories and usb sockets consumer unit options to support 17th edition...

8
PROTECTION Flexible solutions to support 17th Edition Wiring Regulations compliance CIRCUIT

Upload: vodien

Post on 30-Apr-2018

215 views

Category:

Documents


2 download

TRANSCRIPT

PROTECTIONFlexible solutions to support

17th Edition Wiring Regulations compliance

CIRCUIT

• Smooth finish enables easy cleaning

• Rigid robust construction

• UV stable will not discolour with sunlight or age

• Hooded trunking entry enables neat finish• Easy cable entry all sides and rear, via standard trunking cut-outs

• Quick removal of cover using ¼ turn combi screws

• Consumer unit and devices tested to all relevant standards

• Modern stylish design with a profile that matches Nexus wiring accessories• Quality designed in• Flexibility for maximum circuit combinations, and easy upgrades• Fast and simple installation

• With a solid downward opening visor to cover devices

• Easy fit cover provides quick fit to base and caters for uneven wall surfaces

ProtectionCircuit

02

• Large accessible wiring space provided by lower base walls, raised DIN rail, wide device to terminal distance and offset main switch

• Fast fit to wall, using keyholes and integral spirit level

• Captive backed out terminal screws provides fast connection and no loss of screws

• Ensured cable retention, due to large higher torque terminal screws and cables fitted with crimps

Option to provide highintegrity solutions with standard Dual RCD 16 and 22 module consumer units

• Fast release of DIN rail using key holes

• One height floating busbar, can be cut to any length for any consumer unit configuration

• Terminal and busbar design enables installer to select a wide combination of protected or unprotected circuits

• Optional 5 point fixing of base caters for uneven wall surfaces

ProtectionCircuit

03

For 17th Edition Compliant Installations

Since 1st July 2008 the 17th Edition Wiring Regulations has

required the installation of ‘Additional Protection’, by means

of 30mA RCDs on many circuits which previously may not

have needed protection by RCDs.

It is important that a single fault does not inconvenience or

cause increased danger for others, e.g. lights going out if

fault on a socket. Therefore, the use of more than one RCD

is required. Different types and sizes of property, will require

different design considerations, and different equipment can

enable some circuits to be grouped together on one RCD.

Whereas other circuits may require a dedicated supply,

e.g. smoke alarms and warden call.

British Standard and IEE Regulations are subject to change,

please always refer to the latest standards for all types of

electrical design and installation work.

BG offers a variety of circuit protection solutions, that will

help the designer and installer to comply and meet these

new regulations.

The following areas require additional protection by an RCD not exceeding 30mA:-

i) Socket Outlets (section 411.3.3)- All sockets up to 20A.

- All mobile equipment up to 32A, used outdoors.

- Exceptions are socket outlets under supervision of someone skilled/instructing, and labelled

socket, e.g. ‘Freezer’.

ii) Cables buried in walls (section 522)- All cables concealed in a wall/partition less than 50mm depth, and without earthed mechanical

protection, e.g. earthed metal conduit.

iii) Location containing a bath or a shower ( section 701.411.3.3)- All circuits within these locations must have additional protection by an RCD.

iv) Installations to be divided (section 314)- All circuits of an installation should not be connected to a single RCD. This avoids hazards and

minimises inconvenience to others by reducing unwanted tripping.

ProtectionCircuit

04

BG Consumer Unit Options

Standard Dual RCD consumer unit offersoption of High Integrity Dual RCDas standard.

RCD3 RCD2 RCD1MAIN

SWITCHSPARE RCBO

RCBO

SPARE

MCB

MCB

SPARE

MCB

MCB

MCB

SPARE

MCB

MCB

MCB

Possible consumer unit options to support17th Edition Wiring Regulations compliance.Note:- The following diagrams use a 16 module consumer unitto demonstrate the available options.

1. Main Switch• Main switch plus the use of RCBOs

for every circuit

2. Split Load• Some circuits using MCBs protected by an RCD

• Other independent circuits using RCBOs

3. Dual RCD• Some circuits using MCBs protected by an RCD1

• Some circuits using MCBs protected by an RCD2

4. High Integrity Dual RCD• Some circuits using MCBs protected by an RCD1

• Some circuits using MCBs protected by an RCD2

• Other independent circuits using RCBOs

5. High Integrity Triple RCD*• Some circuits using MCBs protected by an RCD1

• Some circuits using MCBs protected by an RCD2

• Some circuits using MCBs protected by an RCD3

• Other independent circuits using RCBOs

* Only suitable for 22 module consumer unit

MAINSWITCH

SPARE

SPARE

SPARE

SPARE RCBO

RCBO

RCBO

RCBO

RCBO

RCBO

RCBO

RCBO

RCBO

RCBO

MAINSWITCHRCD2 RCD1

SPARE RCBO

RCBO

SPARE

MCB

MCB

SPARE

MCB

MCB

MCB

MAINSWITCHRCD2 RCD1

SPARE

MCB

MCB

SPARE

MCB

MCB

MCB

MCB

MCB

MCB

RCDMAIN

SWITCHSPARE

SPARE RCBO

RCBO

RCBO

MCB

MCB

MCB

MCB

MCB

MCB

MCB

Module 22

Module 16

Module 12

ProtectionCircuit

05

CUE5W CUE4 CUE4M

CUD6610

CUSL8012

CUSW14

Metalclad units have 1.2mm steel base with insulated plastic cover and visor with 20and 32mm knockoutsInsulated units supplied with 40x16, 25x16, 16x16mm cutoutsEach consumer unit supplied with two cover blanks

MAIN SWITCH CONSUMER UNITS

CUSW10CUSW14CUSW20

CUSW10MCUSW14MCUSW20M

10 way with 100A switch14 way with 100A switch20 way with 100A switch

121622

101420

---

101420

Catalogue NumberInsulated

Description Modules Max No. WaysSwitch Max Total

Max Total

Max Total

Each consumer unit supplied with two cover blanks# denotes supplied as kit

SPLIT LOAD CONSUMER UNITS

CUSL808

CUSL8012

CUSL8018

CUSL808M#

CUSL8012M#

CUSL8018M#

8 way with 100A switchand 80A 30mA RCD12 way with 100A switchand 80A 30mA RCD18 way with 100A switchand 80A 30mA RCD

12

16

22

5

9

10

6

9

11

8

12

18

Catalogue NumberInsulated

Description Modules Max No. WaysSwitch RCD

Includes 40A, 4x32A, 2x16A and 3x6A MCBs Includes 50A, 40A, 4x32A, 2x16A, 10A and 3x6A MCBs# denotes supplied as kit Each consumer unit supplied with two cover blanks Dual RCD units supplied with optional High Integrity as standard Terminal and busbar design provide maximum flexibility for combination of protected or unprotected circuits

DUAL RCD CONSUMER UNITS

CUD6610

CUD8610

CUDP16610

CUD6616

CUD8616

CUDP16616

CUD6610M

CUD8610M#

CUDP16610M#

CUD6616M

CUD8616M#

CUDP16616M#

10 way with 100A switchand 2 × 63A 30mA RCD10 way with 100A switchand 80 and 63A 30mA RCD10 way with 100A switch,2×63A 30mA RCDand cw 10 × MCBs*16 way with 100A switchand 2 × 63A 30mA RCD16 way with 100A switchand 80 and 63A 30mA RCD16 way with 100A switch,2×63A 30mA RCDand cw 12 × MCBs**

16

16

16

22

22

22

5

5

5

up to 9

up to 9

up to 9

7

7

7

up to 11

up to 11

up to 11

7

7

7

up to 13

up to 13

up to 13

10

10

10

16

16

16

Catalogue NumberInsulated

Choice of insulated and metal enclosuresEnclosures either IP30 or IP55 (weatherproof)Available in 4 or 5 modulesEnclosure kits supplied complete with devices, DIN rail, neutral cable, neutral & earth terminals, and busbarAll BG devices can be used with enclosures, except RCBOsManufactured and tested to EN 60439

ENCLOSURES

CUE4CUE4MCUE5WCUGAR1CUSHOW1

Insulated - IP30Metal - IP30Weatherproof - IP55Garage Kit - IP55, 40A 30mA RCD, 6+32A MCBShower Kit - IP55, 63A 30mA RCD, 50A MCB

44555

Catalogue Number Description Modules

Description Modules Max No. WaysSwitch RCD1 RCD2

Metal

Metal

Metal

***

For further technical information, or installation advice please visit our website

www.bgelectrical.co.uk

ProtectionCircuit

06

CUSW100

CURB32

CUR6330

CUMB6

CUTS5 CUTS10CUC20

MAIN SWITCH (ISOLATOR)

CUSW100 Double Pole 52100A

Catalogue Number

CartonQty

Description Rating Modules

Positive contact status indication

MCBs

CUMB6CUMB10CUMB16CUMB20CUMB32CUMB40CUMB50

CUMC6CUMC10CUMC16CUMC20CUMC32CUMC40CUMC50

Single Pole, Breaking Capacity 6kASingle Pole, Breaking Capacity 6kASingle Pole, Breaking Capacity 6kASingle Pole, Breaking Capacity 6kASingle Pole, Breaking Capacity 6kASingle Pole, Breaking Capacity 6kASingle Pole, Breaking Capacity 6kA

Catalogue Number Description

10101010101010

1111111

6A10A16A20A32A40A50A

CartonQty

Rating Modules

Positive contact status indication

RCBOs

CURB6CURB10CURB16CURB20CURB32CURB40

Single Pole, Type B, Breaking Capacity 6kASingle Pole, Type B, Breaking Capacity 6kASingle Pole, Type B, Breaking Capacity 6kASingle Pole, Type B, Breaking Capacity 6kASingle Pole, Type B, Breaking Capacity 6kASingle Pole, Type B, Breaking Capacity 6kA

Catalogue Number

Description

555555

111111

6A10A16A20A32A40A

CartonQty

Rating Modules

Positive contact status indication

RCDs

CUR4030CUR6330CUR8030CUR80100CUR80100TD

Double Pole, Type ACDouble Pole, Type ACDouble Pole, Type ACDouble Pole, Type ACDouble Pole, Type AC, Time Delayed

Catalogue Number

Description

55555

22222

40A 30mA63A 30mA80A 30mA80A 100mA80A 100mA

CartonQty

Rating Modules

Positive contact status indication

All devices are capable of being locked in ON or OFF position using device lock (CUA10) and padlockCable kit enables consumer unit upgrade from main switch to Split load, or Split Load to Dual RCD,or Dual RCD to Triple RCD (22 module unit only)

CONTROL DEVICES

CUC20CUC40CUB1CUTS1CUTS5CUTS10CUTS11

Contactor 20A Double PoleContactor 40A Double PoleBell TransformerTime Delay Switch, 1-7 minsTimer Analogue 24 HrTimer Digital 1 ChannelTimer Digital 2 Channels

Catalogue Number

Description

5555555

1221322

CartonQty

Modules

ACCESSORIES

CUA01CUA02CUA03CUA05CUA05CUA10CUA11

Consumer Unit Cover Blanks (pack of 10)Busbar 21 WayBusbar Shield 21 wayCable Kit includes neutral and live cables, terminal bar,fixing clip and spare labelsDevice LockSpare label sheets (Pack of 5)

Catalogue Number

Description

1010105

CUA051010

CartonQty

Type B Type C

ProtectionCircuit

07

Standards

Consumer Unit Insulated (A) Metal (A) 12 Modules 317mm 317mm16 Modules 389mm 389mm22 Modules 497mm 497mm

Device Capacity mm2 Max Torque NmSwitch 35 2.5MCB 16 (32-50A 25mm2) 2RCD 35 2.5 (80A 3.5Nm)RCBO 16 (32-40A 25mm2) 2

Terminals

Range Top & Bottom Face Each Side BaseInsulated 12 Module 4 off - 40, 25, 16 x 16mm 40, 25, 16 x 16mm 50mm x 50mm x 3Insulated 16 Module 6 off - 40, 25, 16 x 16mm 40, 25, 16 x 16mm 50mm x 50mm x 3Insulated 22 Module 8 off - 40, 25, 16 x 16mm 40, 25, 16 x 16mm 50mm x 50mm x 3Metal 12 Module 7 x 20mm, 1 x 32mm 1 x 32mm 50mm x 50mm x 3Metal 16 Module 8 x 20mm, 2 x 32mm 1 x 32mm 50mm x 50mm x 4Metal 22 Module 10 x 20mm, 2 x 32mm 1 x 32mm 50mm x 50mm x 5

Cut Outs and Knock Outs

• Positive contact status indication on Switch, MCB, RCD & RCBO provided by green indicator to show contacts are open

InsulatedAll

117mm

234m

m

A 122mm

234m

m

Metal

Dimensions

Devices – Pole pitch 18mm

Consumer UnitMax current rating 100AOperating Voltage 230VShort circuit withstand 16kA rmsMetal CU base manufactured from 1.2mm steel

RCD Type AC Tripping Time : 1 x In �100mS

5 x In 40mS

RCBO Type ACPoles: 1 (1P+N)

MCB Breaking capacity 6000AType B operating 3-5 x InType C operating 5-10 x In

<_

<_

Product StandardConsumer Unit BS EN 60439-3Main Switch EN/IEC 60947-3MCB EN/IEC 60898RCBO EN/IEC 61009-1

Product StandardRCD EN/IEC 61008Enclosure EN/IEC 60439Contactor EN/IEC 60947, 61095Bell Transformer EN/IEC 61558-1

ProtectionCircuit

ContactorsPoles: 2 (1+N), NO (Normally Open)

Bell Transformer- Output voltage 4,6,8,12,16, 24V- Rated output 8VA- Consumption 1.15W