chevron / zigzag pad designs for gas trackers
DESCRIPTION
Chevron / Zigzag Pad Designs for Gas Trackers. Bo Yu Instrumentation Division. Outline. Overview of various interpolating readout methods Some results from BNL groups with GEMs An example of a TPC with “integrated front-end electronics” Summary. Resistive Charge Division. AGS E814 DC1. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/1.jpg)
Chevron / Zigzag Pad Designs for Gas Trackers
Bo Yu
Instrumentation Division
![Page 2: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/2.jpg)
Outline
Overview of various interpolating readout methods Some results from BNL groups with GEMs An example of a TPC with “integrated front-end
electronics” Summary
![Page 3: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/3.jpg)
Resistive Charge Division
AGS E814 DC1
J.L. Alberi and V. Radeka, IEEE Trans. Nucl. Sci. NS-23 (1976) 251
The spread (fwhm) of the induced charge on the cathode is about 1.6 times the anode to cathode distance
![Page 4: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/4.jpg)
Geometrical Charge Division
Wedge and strip electrode patterns:
H.O. Anger, Instr. Soc. Am. Trans. 5 (1966), p311
C. Martin, et al., Rev. Sci. Instr. 52 (1981), p1067
Backgammon cathode
R. Allemand and G. Thomas, NIM. 137 (1976), p141
Zigzag pad/strip cathodes:
T. Miki, R. Itoh and T. Kamae, NIM. A236 (1985), p64.
E. Mathieson and G.C. Smith, IEEE TNS. vol 36 (1989), p305
![Page 5: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/5.jpg)
Linearity of several chevron patterns
Patterns of (a) centered single chevron (b) displaced single chevron (c) centered one & a half chevron (d) displaced one & a half chevron (e) centered double chevron (f) displaced double chevron.Dashed line indicates anode wire position
![Page 6: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/6.jpg)
Capacitive Charge Division
(a) Single Intermediate Strip method (b) Two Intermediate Strip method
G.C. Smith, et al., IEEE TNS vol. 35 (1988), p409.
![Page 7: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/7.jpg)
Interpolating Cathode Patterns with MWPCs
![Page 8: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/8.jpg)
Linearity vs. Readout Pitch
![Page 9: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/9.jpg)
Interpolating Pad Readout with GEMs
i
iic Q
Qxx
Totalc Q
ENCwx 2
The spread of the electron cloud at the anode pad plane is mostly determined by the diffusion process. It is typically well under 1mm.
A rectangular pad with a width larger than the FWHM of the charge cloud will exhibit large position non-linearity.
A zigzag shaped pad with a zigzag periodicity under 1mm will give better position linearity. The width of the pad can be much larger than the charge cloud.
Pad width w periodicity
The position of the ionization center can be derived from the weighed average of the charge on the pads
The position resolution of the centroid is limited by the signal to noise ratio of the electronics, and the readout pitch
For 2-3 ch.
![Page 10: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/10.jpg)
A Double GEM Chamber with Strip Anode PlaneThe detector used for most of the measurement, courtesy of Dr. Sauli from CERN.
![Page 11: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/11.jpg)
Measure the Charge Spread on the Anode Plane
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
X-ray Position [mm]
Re
lativ
e P
uls
e H
eig
ht [
a.u
.]
A
B
C
D
Most probable pulse height from a set of 4 anode strips at 0.4mm pitch as a function of x-ray position @ 0.1mm steps
3mm drift gap, 2mm transfer gap, 2mm induction gap, Ar+20% CO2
The charge spread is comparable to a Gaussian with ~ 0.2mm
![Page 12: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/12.jpg)
“Line Response” of a Coarse Zigzag Pattern
0
500
1000
1500
2000
2500
3000
2000 3000 4000 5000 6000 7000 8000
Reconstructed Position [µm]
Cou
nt
5.4 keV x-ray beam (0.1mmx3mm) stepped at 100µm intervals
![Page 13: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/13.jpg)
“Line Response” of a Fine Zigzag Pattern
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
2000 3000 4000 5000 6000 7000 8000
Reconstructed Position [µm]
Co
un
t
-100
-80
-60
-40
-20
0
20
40
60
80
100
3000 3500 4000 4500 5000 5500 6000 6500 7000
Reconstructed Position [µm]
Po
sit
ion
Err
or
[µm
]5.4 keV x-ray beam (0.1mmx3mm) stepped at 100µm intervals, center of gravity algorithm, Argon+20% CO2, ~1cm deep
Overall rms position error: 93µm
Including ~ 100µm fwhm x-ray photoelectron range,
100µm beam width, and alignment errors.
![Page 14: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/14.jpg)
Intermediate Strip Patterns
Single Intermediate Zigzag
Two Intermediate Strips
Other interpolating pad designs and their x-ray uniform irradiation responses
![Page 15: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/15.jpg)
Fine “Zigzag” pattern
2 mm x 10 mm pads
Chevron Readout with GEMs
Scan perpendicular to padsIntegrate signal along pad (8 mm)
Scan with X-rays50m x 8 mm100 m steps
R.Wilcox, B Azmoun (BNL)
![Page 16: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/16.jpg)
Pattern APE σ Resolution
Fine Chevron (no Floating Pads) 85.3 μm 108.0 μm 128.2 μm
Coarse Chevron (no Floating Pads) 34.3 μm 187.4 μm 183.8 μm
Fine Chevron (with Floating Pads) 42.2 μm 101.2 μm 97.6 μm
Coarse Chevron (with Floating Pads) 46.2 μm 106.2 μm 104.5 μm
Intermediate - - -
Straight Strips 59.6 μm 108.6 μm 113.3 μm
Interpolating Pad ReadoutNo floating strips Floating strip
patterns
R.Wilcox, B Azmoun (BNL)
![Page 17: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/17.jpg)
Schematic View of the LEGS TPC
HV Cathode Plane Double GEM planes
Interpolating anode pad plane with front-end ASICs (7296 channels)
Digital readout board
![Page 18: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/18.jpg)
Layout of the Anode Pad / ASIC Board
Pad size: ~2mmx5mm, 22 rowsTotal # of Channels: 7296
•High density interconnect traces with 0.006” width and spacing
•Gas tight construction: large number of blind vias
•Cylindrical geometry: no auto-routing of the traces
![Page 19: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/19.jpg)
The Completed Anode Pad/ASIC Board
![Page 20: Chevron / Zigzag Pad Designs for Gas Trackers](https://reader036.vdocuments.us/reader036/viewer/2022062301/56814073550346895dabf21e/html5/thumbnails/20.jpg)
Summary
Interpolating readout provides an economical way of achieving good position resolution with fewer readout channels
It requires pulse height information (ADCs) for centroid reconstruction low noise, high dynamic range electronics
Double track resolution is degraded somewhat Chevron/zigzag readout has some “quirks” that the
designers need to be aware of Large area, high channel density, low mass pad plane is
challenging