U N C L A S S I F I E D Characterization of Particles dV id U i X Mi and Voids Using X-ray Micro Tomography Tomography Brian M. Patterson, E.K. Cerreta, D. Dennis-Koller, C.A. B kh t dCEH ilt Bronkhorst, and C. E. Hamilton Los Alamos National Laboratory, Los Alamos, NM 87545 Tomography Workshop 2010 U N C L A S S I F I E D

Upload: others

Post on 14-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Characterization of Particles d V id U i X Miand Voids Using X-ray Micro

TomographyTomographyBrian M. Patterson, E.K. Cerreta, D. Dennis-Koller, C.A.

B kh t d C E H iltBronkhorst, and C. E. Hamilton

Los Alamos National Laboratory, Los Alamos, NM 87545

Tomography Workshop 2010

U N C L A S S I F I E D

Page 2: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

OverviewOverview

How many radiographs do you need for y g p ydimensional quantification?

How many voxels do you need for object How many voxels do you need for object particle statistics, not image artifacts?

Dynamically damaged Cu Dynamically damaged Cu

U N C L A S S I F I E D

Page 3: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Xradia Micro Computed TomographyXradia Micro Computed Tomography

150 kV, 10W, W-source2 glass slides for beam hardening10X objective ~2.5 mm FOV2.24 μm voxel size

17~24 hrs per sample for best image quality

Great for meso scale features

U N C L A S S I F I E D

Page 4: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Analysis Using AvizoFireAnalysis Using AvizoFire3D image analysis using AvizoFire 6.2g y g

64-bit, HP workstation, Windows 7, Nvidia FX-5600 graphics card with 4gb ram

The use of μCT lends 3D statistics to traditional 2D characterization. Exciting new capability and g p yextremely useful if implemented carefully.

U N C L A S S I F I E D

Page 5: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Calibrated Volume MeasurementsCalibrated Volume MeasurementsEmbedded solid NIST standard beads in 60 mg/cm3 polymer

3D image of NIST standard beads using X-ray CTvaried the number of x-ray images to determine

1. can beads be used as standards2. are the 3D measurements accurate

Data sets of:181, 361, 721, 1261 images collected

U N C L A S S I F I E D

PATTERSON, B.M. & HAMILTON, C.E. (2010). Analytical Chemistry 39(3), 184-190.

Page 6: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Photomicrograph of glass spheresg p g p

Geometry of x-ray tomography instrument

U N C L A S S I F I E D

PATTERSON, B.M. & HAMILTON, C.E. (2010). Analytical Chemistry 39(3), 184-190.

Page 7: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Reconstructed slices through sphere embedded polymer

1261 721

Reconstructed slices through sphere embedded polymer

361 181

U N C L A S S I F I E D

PATTERSON, B.M. & HAMILTON, C.E. (2010). Analytical Chemistry 39(3), 184-190.

Page 8: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Histogram of binary particlesHistogram of binary particles

U N C L A S S I F I E D

PATTERSON, B.M. & HAMILTON, C.E. (2010). Analytical Chemistry 39(3), 184-190.

Page 9: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

20 micron beads, 1261 images, g

U N C L A S S I F I E D

PATTERSON, B.M. & HAMILTON, C.E. (2010). Analytical Chemistry 39(3), 184-190.

Page 10: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Average bead diameter calculation comparison

1261

Average bead diameter calculation comparison

NIST Standard 1261 Radiographs 721 Radiographs 361 Radiographs 181 Radiographs

Average Bead Diameter

(μm) and SD17.3 ± 1.4 18.4 ± 1.9 17.8 ± 1.9 17.4 ± 1.9 17.0 ± 1.9

(μm) and SD

R l ti %Relative % SD 12 10.7 10.8 11.1 11.2

U N C L A S S I F I E D

PATTERSON, B.M. & HAMILTON, C.E. (2010). Analytical Chemistry 39(3), 184-190.

Page 11: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

How many voxels?How many voxels?

No one would believe that the surface area of a single voxel object is accurate!What about a 5 voxel object? jWhat about a 50 voxel object?

U N C L A S S I F I E D

Page 12: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

27 cylinders in various resampled datasets

9003 1003 253

27 cylinders in various resampled datasets

900 100 25

U N C L A S S I F I E D

Page 13: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Slice through one cylinder in various resampled datasets

9003 1003 253

g y p

9003 1003 253

U N C L A S S I F I E D

Page 14: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Define Feret Shape 3DDefine Feret Shape 3D

U N C L A S S I F I E D

Page 15: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Accuracy measures as a function of the ynumber of object voxels

U N C L A S S I F I E D

Page 16: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Precision measure of the cylinders as f i f b f la function of number of voxels

U N C L A S S I F I E D

Page 17: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Numerous industrial applications call for damage tolerant materials in extreme environments

Crash WorthinessVulnerability and Safety

Structural Integrity

Foreign Object Damage

A future of materials with designer properties relies on our capabilityU N C L A S S I F I E D

A future of materials with designer properties relies on our capability to understand and predict the response of such materials in the

extreme environments of stress, strain, temperature, and pressure.

Page 18: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Experimentally we mimic this effect through gas gun, laser drive or high explosive loading platformsg p g p

Damage in a shocked specimenquartz Cu targetm

e

impactor targetup

t tim

x

Flat top loading

(supported)

t

Discreet

U N C L A S S I F I E D

Discreetregion of tension

Page 19: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

3 2 1About ~ 7 mm available for analysis

h= ~ 4 2 mmHigh purity OFHC copper

h= ~ 4.2 mm

thickness = ~ 1.7 mmthickness 1.7 mm

U N C L A S S I F I E Dw = ~1.95 mm

Page 20: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Shocked SamplesShocked Samples

U N C L A S S I F I E D

Page 21: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Flow chart for segmentation

U N C L A S S I F I E D

Page 22: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Smoothed Arithmetic

Dilation MaskDilation Mask

U N C L A S S I F I E D

Page 23: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Smoothed 3D image of voids in damaged Cug g

U N C L A S S I F I E D

Page 24: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Feret Shape Cut-Offp

All voids with 1000 voxels or moreAll voids

U N C L A S S I F I E D

Page 25: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Is it accurate?Is it accurate?

Void volume by 2D areay0.41%

Void Mass Void Mass0.42%

CT CT0.64%

U N C L A S S I F I E D

Page 26: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Cu damaged at higher velocityCu damaged at higher velocity

3 t3mm quartz171 m/s

U N C L A S S I F I E D

Page 27: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

U N C L A S S I F I E D

Page 28: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Normalized Radius of Voids40

30

20

mbe

r of V

oids

10

Num

113 total number of voids with a volume greater than 27 voxels

0 50 100 150 2000

g

U N C L A S S I F I E D

Normalized Radius (micrometers)

Page 29: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Binary and Labeled Reconstructed Slicey

U N C L A S S I F I E D 0.25 mm

Page 30: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

U N C L A S S I F I E D

Page 31: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

Normalized Radius of Voids

35

40

Individual voids

Normalized Radius of Voids

30

35 Individual voids

20

25

ber o

f Voi

ds

10

15

Num

b

Large void virtually separated

0 50 100 150 2000

5 Congealed void

U N C L A S S I F I E D

0 50 00 50 00

Normalized Radius (m icrometers)

Page 32: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

SummarySummaryX-ray Micro CT coupled with high end image processing provides a non-destructive 3D characterization of meso scale damage structures in a laboratory based environment. Information on the resultant process’ are imaged; not available in typical 2D cross sectioning.

Now we can balance resolution versus field of view.

U N C L A S S I F I E D

Page 33: Characterization of Particles andV id U i Xd Voids Using X ...mpg.web.cmu.edu/html/Tomography_workshop_Patterson.pdf · andV id U i Xd Voids Using X-ray Micro Tomography Brian M

U N C L A S S I F I E D

AcknowledgmentsAcknowledgments

Funding was provided by the LaboratoryFunding was provided by the Laboratory Directed Research and Development program(LDRD DR 20100026)(LDRD-DR-20100026)

PATTERSON B M & HAMILTON C E (2010) Analytical Chemistry 39(3) 184 190PATTERSON, B.M. & HAMILTON, C.E. (2010). Analytical Chemistry 39(3), 184-190.

Patterson, B.M. et. al., (2011), Microscopy and Microanalysis, submitted 12/10.

U N C L A S S I F I E D