ERRATA I - 54 January 2016 For unwelded members F s = F so (H.2-3) For welded members F s = F so (1 – A wz /A g ) + F sw A wz /A g (H.2-4) where F so = shear stress corresponding to the torsional strength for an element determined using Section H.2 if no part of the cross section were weld-affected. Use buckling constants for unwelded metal (Table B.4.1 or Table B.4.2) and F sy . F sw = shear stress corresponding to the torsional strength for an element determined using Section H.2 if the entire cross section were weld-affected. Use buckling constants for weld-affected zones (Table B.4.1) and F syw . A wz = cross sectional area of the weld-affected zone A g = gross cross sectional area of the element. H.2.1 Pipes and Round or Oval Tubes The nominal torsional strength T n for pipes and round or oval tubes is T n = F s J /R (H.2-5) For the limit state of torsional rupture, the shear stress F s corresponding to the torsional strength shall be determined in accordance with Section H.2. For the limit state of torsional yielding and torsional buck- ling, the shear stress F s corresponding to the shear strength is LIMIT STATE F s λ yielding F sy λ < λ 1 inelastic buckling B s – 1.25D s λ λ 1 < λ < λ 2 elastic buckling E (1.25λ) 2 π 2 λ > λ 2 where λ 1 = B F D 1.25 s sy s λ 2 = C 1.25 s Buckling constants B s , D s , and C s are given in Table B.4.1 or B.4.2. This chapter addresses members subject to axial force and flexure about one or both axes, with or without torsion, and to members subject to torsion only. H1 MEMBERS SUBJECT TO FLEXURE AND AXIAL FORCE For members subject to flexure and axial force, + + P P M M M M r c rx cx ry cy < 1.0 (H.1-1) where all terms are positive, and x = subscript for major principal axis bending y = subscript for minor principal axis bending P r = required axial strength P c = available axial strength determined in ac- cordance with Chapter D for axial tension and Chapter E for axial compression M r = required flexural strength M c = available flexural strength determined in accordance with Chapter F H2 MEMBERS SUBJECT TO TORSION The available torsional strength of members is the least of the available strengths for the limit states of rupture, yield- ing, and buckling. The available torsional strength (φ T T n for LRFD and T n /Ω T for ASD) shall be determined in accor- dance with this Section and Sections H.2.1, H.2.2, H.2.3, or H.2.4, where T n is the nominal torsional strength and LIMIT STATE φ T building-type structures Ω T building-type structures Ω T bridge-type structures torsional rupture 0.75 1.95 2.20 other torsional limit states 0.90 1.65 1.85 For the limit state of torsional rupture, the shear stress F s corresponding to the torsional strength is For unwelded members F s = F su /k t (H.2-1) For welded members F s = F su (1 – A wz /A g ) /k t + F suw A wz /A g (H.2-2) For the limit states of shear yielding and shear buckling, the shear stress F s corresponding to the torsional strength is Chapter H Design of Members for Combined Forces and Torsion

Upload: others

Post on 15-May-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Chapter H Design of Members for Combined Forces and Torsion · 2017-07-12 · H .2 MEMBERS SUBJECT TO TORSION The available torsional strength of members is the least of the available

ERRATA

I - 54 January 2016

For unwelded members

Fs = Fso (H.2-3)

For welded members

Fs = Fso(1 – Awz /Ag) + Fsw Awz /Ag (H.2-4)

where Fso = shear stress corresponding to the torsional strength

for an element determined using Section H.2 if no part of the cross section were weld-affected. Use buckling constants for unwelded metal (Table B.4.1 or Table B.4.2) and Fsy.

Fsw = shear stress corresponding to the torsional strength for an element determined using Section H.2 if the entire cross section were weld-affected. Use buckling constants for weld-affected zones (Table B.4.1) and Fsyw.

Awz = cross sectional area of the weld-affected zone Ag = gross cross sectional area of the element.

H.2.1 Pipes and Round or Oval Tubes

The nominal torsional strength Tn for pipes and round oroval tubes is

Tn = Fs J /R (H.2-5)

For the limit state of torsional rupture, the shear stress Fs corresponding to the torsional strength shall be determined in accordance with Section H.2.

For the limit state of torsional yielding and torsional buck-ling, the shear stress Fs corresponding to the shear strength is

LIMIT STATE Fs λ

yielding Fsy λ < λ1

inelastic buckling Bs – 1.25Ds λ λ1 < λ < λ2

elastic bucklingE

(1.25λ)2π2

λ > λ2

where

λ1 = −B F

D1.25s sy

s

λ2 = C

1.25s

Buckling constants Bs, Ds, and Cs are given in Table B.4.1 or B.4.2.

This chapter addresses members subject to axial force and flexure about one or both axes, with or without torsion, and to members subject to torsion only.

H .1 MEMBERS SUBJECT TO FLEXURE AND AXIAL FORCE

For members subject to flexure and axial force,

+ +P

P

M

M

M

Mr

c

rx

cx

ry

cy

< 1.0 (H.1-1)

where all terms are positive, and x = subscript for major principal axis bending y = subscript for minor principal axis bending

Pr = required axial strengthPc = available axial strength determined in ac-

cordance with Chapter D for axial tension and Chapter E for axial compression

Mr = required flexural strengthMc = available flexural strength determined

in accordance with Chapter F

H .2 MEMBERS SUBJECT TO TORSION

The available torsional strength of members is the least of the available strengths for the limit states of rupture, yield-ing, and buckling. The available torsional strength (φTTn for LRFD and Tn /ΩT for ASD) shall be determined in accor-dance with this Section and Sections H.2.1, H.2.2, H.2.3, or H.2.4, where Tn is the nominal torsional strength and

LIMIT STATEφT

building-type structures

ΩT

building-type structures

ΩT

bridge-type structures

torsional rupture 0.75 1.95 2.20

other torsional limit states

0.90 1.65 1.85

For the limit state of torsional rupture, the shear stress Fs corresponding to the torsional strength is

For unwelded members

Fs = Fsu /kt (H.2-1)

For welded members

Fs = Fsu(1 – Awz /Ag) /kt + Fsuw Awz /Ag (H.2-2)For the limit states of shear yielding and shear buckling,

the shear stress Fs corresponding to the torsional strength is