Page 1: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

Feedback Controllers

Page 2: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

On-off Controllers

• Simple• Cheap• Used In residential heating and domestic refrigerators• Limited use in process control due to continuous

cycling of controlled variable excessive wear on control valve.

ExamplesExamples•Batch process control (PLC = programmable logic controller)•Solenoid in home heating unit•Sprinkler systems•Cruise control?

Ch

apte

r 7

Page 3: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

On-Off Controllers

Synonyms:“two-position” or “bang-bang” controllers.

Controller output has two possible values.

Ch

apte

r 7

e = error = set point – measured variable

Page 4: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Practical case (dead band)

Ch

apte

r 7

system never reaches steady-state

δ = tolerance

Page 5: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

Page 6: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Three Mode (PID) Controller • Proportional• Integral• Derivative

Proportional Control• Define an error signal, e, by e = Ysp – Ym

whereYsp = set pointYm = measured value of the controlled variable (or equivalent signal from transmitter)

Ch

apte

r 7

Page 7: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Since signals are time varying,

e(t) = Ysp(t) - Ym (t)

n.b. Watch units!!

• For proportional control: where, p(t) = controller output = bias value (adjustable) Kc = controller gain (dimensionless, adjustable)

p-p=p e(t)K+p=p(t) c

Ch

apte

r 7

p

Page 8: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

Standards (ISO/ISA)

3 – 15 psi4 - 20 ma0 – 10 VDC

Page 9: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Proportional Band, PB

Reverse or Direct Acting Controller Kc can be made positive or negative Recall for proportional FB control:

or

Direct-Acting (Kc < 0)“output increases as input increases"

p(t) Ym(t)

Reverse-Acting (Kc > 0)“output increases as input decreases"

cK

%100PB

e(t)K+p=p(t) c

Ch

apte

r 7

)t(Y)t(YKp)t(p mspc

Page 10: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

• Example 2:Example 2: Flow Control Loop

Assume FT is direct-acting. Select sign of Kc so that KcKv > 0

1.) Air-to-open (fail close) valve ==> ?2.) Air-to-close (fail open) valve ==> ?

• Consequences of wrong controller action??

Ch

apte

r 7

Page 11: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Transfer Function for Proportional Control:Let

Then controller input/output relation can written as

Take Laplace transform of each side,

or

INTEGRAL CONTROL ACTIONSynonyms: "reset", "floating control"

I reset time (or integral time) - adjustable

p-p(t)(t)p

e(t)K(t)p c

E(s)K(s)P c

cKE(s)

(s)P

s

1

E(s)

(s)P td)t(e

1p)t(p

I

t

0I

Ch

apte

r 7

Page 12: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

t

0Ic td)t(e

1)t(eKp)t(p

Proportional-Integral (PI) Control

• Response to unit step change in e:

Ch

apte

r 7

integral provides memory of emost popular controller

Page 13: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

• Integral action eliminates steady-state error (i.e., offset) Why??? e 0 p is changing with time until e = 0, where p reaches steady state.

s

11K

E(s)

(s)P

Ic

• Transfer function for PI control

Page 14: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Derivative Control Action Ideal derivative action

Used to improve dynamic response of the controlled variable Derivative kick (use -dym/dt ) Use alone?

Some controllers are calibrated in 1/I

("repeats per minute") instead of I .

p

dt

dep)t(p D

Ch

apte

r 7

For PI controllers, is not adjustable.

Page 15: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

Page 16: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

Proportional-Integral-Derivative (PID) Control

Now we consider the combination of the proportional, integral, and derivative control modes as a PID controller.

• Many variations of PID control are used in practice.

• Next, we consider the three most common forms.

Parallel Form of PID Control

The parallel form of the PID control algorithm (without a derivative filter) is given by

0

1* * τ (8-13)

τ

tc D

I

de tp t p K e t e t dt

dt

Page 17: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

The corresponding transfer function is:

11 τ (8-14)

τc DI

P sK s

E s s

Series Form of PID Control

Historically, it was convenient to construct early analog controllers (both electronic and pneumatic) so that a PI element and a PD element operated in series.

Commercial versions of the series-form controller have a derivative filter that is applied to either the derivative term, as in Eq. 8-12, or to the PD term, as in Eq. 8-15:

τ 1 τ 1(8-15)

τ ατ 1I D

cI D

P s s sK

E s s s

Page 18: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

Expanded Form of PID Control

In addition to the well-known series and parallel forms, the expanded form of PID control in Eq. 8-16 is sometimes used:

0

* * (8-16)t

c I Dde t

p t p K e t K e t dt Kdt

Features of PID Controllers

Elimination of Derivative and Proportional Kick

• One disadvantage of the previous PID controllers is that a sudden change in set point (and hence the error, e) will cause the derivative term momentarily to become very large and thus provide a derivative kick to the final control element.

Page 19: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

Page 20: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Automatic and Manual Control Modes• Automatic Mode

Controller output, p(t), depends on e(t), controller constants, and type of controller used. ( PI vs. PID etc.)

Manual Mode Controller output, p(t), is adjusted manually. Manual Mode is very useful when unusual conditions exist:

plant start-upplant shut-downemergencies

• Percentage of controllers "on manual” ?? (30% in 2001, Honeywell survey)

Ch

apte

r 7

Page 21: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Digital PID Controller

finite difference approximation

where,= the sampling period (the time between successive samples of the controlled variable)= controller output at the nth sampling instant, n=1,2,…= error at the nth sampling unit

velocity form - see Equation (8-19)(pn)- incremental change

1

11

nD

n c n k n nkI

DI

tp p K e e e e

t

np

ne

t

Ch

apte

r 7

Page 22: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

Page 23: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Typical Response of Feedback Control SystemsConsider response of a controlled system after a sustained disturbance occurs (e.g., step change in disturbance variable); y > 0 is off-spec.

Ch

apte

r 7

Page 24: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

Page 25: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

integral action ~ /c IK

Page 26: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control
Page 27: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Summary of the Characteristics of the Most Commonly Used Controller Modes

1. Two Position:Inexpensive.Extremely simple.

2. Proportional:Simple.Inherently stable when properly tuned.Easy to tune.Experiences offset at steady state. (OK for level control)

3. Proportional plus integral:No offset.Better dynamic response than reset alone.Possibilities exist for instability due to lag introduced.

Ch

apte

r 7

Page 28: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

4. Proportional plus derivative:

Stable.

Less offset than proportional alone (use of

higher gain possible).

Reduces lags, i.e., more rapid response.

5. Proportional plus integral plus derivative:

Most complex

Rapid response

No offset.

Best control if properly tuned.

Ch

apte

r 7

Page 29: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Example 3:Example 3: Liquid Level Control• Control valves are air-to-open• Level transmitters are direct acting

Ch

apte

r 7

Page 30: Chapter 7 Feedback Controllers. On-off Controllers Simple Cheap Used In residential heating and domestic refrigerators Limited use in process control

Ch

apte

r 7

Question:Question:1. Type of controller action? Select Kc so that

0c v pK K K

(a) air-to-open valve: sign of Kv?(b) sign of process gain?